INDOOR MEDIUM VOLTAGE SWITCHGEAR UP TO 24kV



Similar documents
INDOOR MEDIUM VOLTAGE SWITCHGEAR - UP TO 24kV. A division of ACTOM Pty Ltd

ALTERNATIVE METHODS FOR INTERNAL ARC TESTS ON 12 KV AND 24 KV METAL-ENCLOSED SWITCHGEARS WITH COMPACT RMU

NATUS NES / NES-H Draw-out Type Medium Voltage Switchgear Systems. Safe energy distribution that meets the highest industrial requirements

Siemens AG Power Transmission and Distribution Medium Voltage Division Mozartstr. 31c Erlangen Germany.

Session Eleven: Development of Standards for MV Switchgear Rated for Arc Protection

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV

Advantages of Fixed Circuit Breaker Switchgear

Voltage Rated operating voltage [kv] Rated power frequency withstand voltage [kv] Rated lightning impulse withstand voltage [kv]

Unified requirements for systems with voltages above 1 kv up to 15 kv

MEDIUM VOLTAGE SUBSTATION PRACTICES Medium Voltage (MV) is defined as: 1000V< MV 44kV

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & Instructions For Installation, Operation & Maintenance

LV MCC LOW VOLTAGE SWITCHGEAR MOTOR CONTROL CENTRE PRODUCT GUIDE

Our brand POWER DYNAMIC PASSION COMMITMENT CREATIVITY. A strong brand for strong products: 8PU Premium. MV Energy

The Intelligent AX1 Switchgear for Medium Voltage

MEDIUM AND HIGH VOLTAGE CAPACITORS, CAPACITOR BANKS AND SYSTEMS

Session Four: Internal Arc Safety in New and Existing Switchgear

FAQs-Main switchboard design criteria

UniGear ZS1. Medium voltage, arc proof, air insulated switchgear for primary distribution

Low Voltage Switchboards The Best Technical Solution for Your Ship

2a. IEM Indoor Metal Clad Medium Voltage Switchgear 15KV a. Section INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std.

Safe and secure distribution of medium voltage with AX1

Medium Voltage Products. ZN1 12 kv arc-proof air-insulated switchgear for primary distribution

New Arc Resistant, Compact Metal Clad Switchgear: Meeting ANSI / UL Design Challenges By Ashok Kulkarni and Predrag Milovac

Switchgear and Metal-Enclosed Bus

e 2 ALPHA Medium Voltage Switchgear Data Sheet K EN

Eaton Safety & Reliability Solutions in the Oil & Gas Industry Electrical

2004 TRANSMISSION SYSTEMS SEMINAR MEDIUM VOLTAGE, METAL-CLAD ARC RESISTANT SWITCHGEAR: ENHANCING WORKPLACE SAFETY

MV, HV AND EHV SWITCHGEAR TESTING & COMMISSIONING

MEDIUM VOLTAGE SWITCHGEAR AND CONTROLGEAR MODEL MS-E. IEC /12 /15 kv 25, 31.5, 40 ka

Power-Zone 4 Arc Resistant Low Voltage Switchgear

Masterclad Medium Voltage Passive Arc-Resistant Switchgear

Secondary Unit Substations

Design of a New Generation of Internal Arc Resistant Switchgear

METAL-CLAD AND METAL-ENCLOSED SWITCHGEAR 3.6KV~40.5KV. tgood.com. Energy. Fast.

UFES Active protection for switchgear

Emirates Aluminium starts up World s first fully integrated power distribution system from ABB

Medium Voltage (MV) & High Voltage (HV) Training Module 6. Date of the presentation

Modular Systems, PPMV, 2014 UniPack-G Glass Fiber Reinforced Polyester Compact Secondary Substation

LIMITING SHORT-CIRCUIT CURRENTS IN MEDIUM-VOLTAGE APPLICATIONS

HVL 5 38 kv Load Interrupter Switchgear. The Standard for Performance, Protection and Dependability

Type-Tested Power Distribution Board 8PT with Rear Busbars. sivacon

P System Cubicles. Certified for more safety

Submit shop drawings for equipment provided under this section Shop drawings shall indicate:

Installation, Operation and Maintenance Instructions. Uniflex ABB PTMV

ELECTRICAL INSULATION TESTING OF HV EQUIPMENT UP TO 33kV

C I R E D 21 st International Conference on Electricity Distribution Frankfurt, 6-9 June 2011

Regulation IO-6.0: Electrical Safety Regulations

Contents. Description. Product Selection Guide

Switchboard system. NorLine 800

Overview Brochure Integrated Power Distribution. Medium Voltage Assembly Solutions

8146/5 Series Breaker Panelboards

Modular Systems wind portfolio overview Power Collection and Grid Connection products

Extend the Life of Existing Switchgear

DATA CENTER UNIQUE CHARACTERISTICS AND THE ROLE OF MEDIUM VOLTAGE VACUUM CIRCUIT BREAKERS

The following components are common to most cubicles; this example is an ABB HK cubicle.

Nothing s BetterThan the Original MODAN Power Distribution Systems

OVERCURRENT & EARTH FAULT RELAYS. To study the protection of equipment and system by relays in conjunction with switchgear.

8. Switchgear and switchgear installations for high voltage up to and including 52 kv (medium voltage)

Medium voltage indoor circuit breakers ANSI/IEC solutions

Securing your electrical installations Prisma,

FFI. Advances in Medium and Low Voltage Power Distribution ESS Metron Expo and Technical Seminars. Presented By: Greg Pelster & Robert Schmid

Engineers Edge, LLC PDH & Professional Training

01.4IB.51200B PowlVac-AR Arc Resistant Switchgear. 5kV & 15kV 1200A, 2000A, 3000A, & 4000A Forced Cooled. Powered by Safety

PRODUCT GUIDE. SL Medium Voltage IEC Vacuum Contactors

Choosing for tranquility

Addendum #2 Contract UK-11-13

Enhancing Personnel Safety with Arc Resistant Equipment

Engineering Specification

How To Choose A Transformer

SENTRON Switching and Protection Devices Air Circuit Breakers

Sample - No Commercial Use

SIVACON The Versatile Low-Voltage Switchboard

Specification Guide. for RVAC. Direct Replacement. AC Medium Voltage. Circuit Breakers

Medium Voltage Switchgear

Defining the Needs of Modern Data Center Power Systems, Low Voltage Circuit Breaker Application

Disconnectors and Earthing Switches 36 kv up to 800 kv

Fusible Disconnect Switch

RE-3 : SOLID TOP RANGE RANGE TOP ONLY

NZECP 14: 1995 ISSN COVER PAGE

A USERS GUIDE TO ARC RESISTANT LOW VOLTAGE SWITCHGEAR & MOTOR CONTROL ANALYTICAL COMPARISON VS ARC FLASH TEST RESULTS

3/2-way Solenoid Valve, direct-acting, NC or NO

GE Power Controls. MiniFORM Switchboards

Intertek Cleeve Road, Leatherhead, Surrey KT22 7SB UK

SF 6 Gas Insulated Switchgear Type SDF for 170 kv

Primary and Secondary Electrical Distribution Systems

Section 9: Power Distribution Equipment Bill Brown, P.E., Square D Engineering Services

High-Voltage Circuit-Breakers 3AP1/ kv up to 550 kv. Power Transmission and Distribution

High Voltage (HV) Electricity System Safety Rules and Associated Safety Guidance

employed to ensure the continuing reliability of critical systems.

IEC & 2 standard. The reference for safe and reliable LV switchboards

SICONT Limit Switches Type 3SE3 upto 500 VAC, 600 VDC, 10A

Fundamentals of Modern Electrical Substations Part 1: Mission of Electrical Substations and their Main Components

HAZARDS, INCLUDING SHOCK, ARC FLASH AND FIRE

Medium voltage products UniSec for Smart Grid Air-insulated medium-voltage secondary distribution switchgear

Dead Tank Circuit Breaker 72PM40-C Proven reliability through common platforms

How To Build A Germany Power Plant

BRANDON AND CLARK INC. // SCOTT W. CLARK, P.E. ELECTRICAL CONTINUING EDUCATION ARC FLASH - NFPA 70E

ELEKTROTEHNI KO PODJETJE Leskoπkova cesta 12, 1000 Ljubljana, SLOVENIA

ARC FLASH CALCULATIONS & LABELING REQUIREMENTS

Low voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application.

Transcription:

INDOOR MEDIUM VOLTAGE SWITCHGEAR UP TO 24kV TRANSMISSION & DISTRIBUTION MV SWITCHGEAR

SBV range of products Prior to 1980, Alstom s indoor switchgear business centered around J&P designed AG and Statter designed ACO ranges of bulk oil circuit breaker equipment. A requirement for modern technology switchgear was identified in the mid- 1970s and in 1976, equipment based on the B-Vac fixed pattern vacuum circuit breaker was introduced. This equipment however, was not well accepted on the local market and by 1978 had made no significant inroads into the modern technology business. In 1978 it was realised that a more cost-effective range of draw-out pattern switchgear would have to be introduced. At that time no suitable designs in GEC distribution switchgear were available and the decision that would lead to the development of Alstom s SBV range of switchgear was taken. SBV vacuum switchgear The SBV equipment was designed to meet virtually all known customer requirements. It includes single and double busbar units. Integral circuit (cable) earthing is offered as a option. Busbar earthing via the circuit breaker is also an available option. SBV equipment is designed for horizontal isolation and withdrawal, offering inter alia, the following advantages: Natural venting of the circuit breaker compartments is permitted and, subsequently, higher continuously rated currents. Pressure relief vents, fitted as a standard to all equipment, are accommodated at the top of the circuit breaker panels. The purpose of the relief vents is to open and relieve over-pressure that will result from the unlikely event of an internal arc fault Freestanding SBV 5 capacitor feeders. thus affording inherent operator safety. In the case of the duplicate busbar compartment, venting of the lower busbar compartment is effected at the longitudinal end of the switchboard. Vacuum interrupters are employed as a switching medium. The advantages of switching in vacuum are considerable. They include: Small interrupter gaps (as low as 6 mm for applications) result in low-energy mechanisms, ensuring long mechanism life. Low-peak arc voltages result in very low arc energy which in turn ensures a long electrical life for the vacuum interrupter and a no-maintenance device. In 1965 three outdoor, fixed-type vacuum circuit breakers, fitted with auto-reclose facilities, were installed on Great Britain s Eastern Electricity Board 11kV networks to assess their performance. Five arduous years of service were insufficient to evaluate the contact wear and loss of vacuum integrity, as none could be detected. The current chopping level of vacuum arc switching is the lowest of all switching media. Of the four switching media (air, oil, SF6 and vacuum), vacuum has by far the best dielectric recovery properties after short-circuit interruption. Vacuum arc switching produces no adverse environmental products, precluding harmful characteristics either towards people or materials. Increased safety due to the absence of oil products in the equipment make-up. Tests The relevant international and national type tests applicable to the Alstom range of switchgear have been carried out by accredited testing authorities such as KEMA and the SABS. Copies of these tests are available on request. It can be stated that, among South African manufacturers of indoor switchgear, ALSTOM Switchgear has been a leader in implementing internal arc testing and actively promotes internal arc testing of switchgear. SBV switchgear has been internally arc tested at 25 ka for 200 milliseconds, as per Eskom requirements. TYPES OF SWITCHGEAR Type SBV 3 & SBV 3E This version is available in single or duplicate busbar arrangements. Circuit and busbar earthing via the circuit breaker are available options. The operating mechanism allows for hand charged spring or motor charged spring application. The mechanism design allows for the following optional features: second shunt trip facility under voltage (no-volt) trip facility direct acting (series) trip facility

including 2 500 A to and including 40 ka for 3 seconds BIL: 95 kv Type SBV4 & SBV4E The SBV4 equipment is available in single busbar configuration only and is of low-profile construction, permitting overall height reduction of the switchgear. Circuit and busbar earthing via the circuit breaker are available options. The operating mechanism allows for hand charged spring or motor charged spring application. The mechanism design allows for the provision of the following optional features: second shunt trip facility under voltage (no-volt) trip facility direct acting (series) trip facility including 2 000 A to and including 31,5 ka for 3 seconds BIL: 95 kv Type SBV5 & SBV5E The SBV 5 circuit breaker was designed for utilisation in the low-profile SBV4 housings and is interchangeable with the SBV4 circuit breaker and vacuum contactors. Circuit and busbar earthing via the circuit breaker are available options. The operating mechanism is of the magnetic actuator type, using closing and tripping coils with the plunger Medium voltage switchboard undergoing preparations for acceptance testing. being held magnetically in the closed or open positions by permanent magnets. The material used for the magnets is neodymium-iron-boron, the field strength of which is almost twice that of samarium cobalt and up to 280 times that of steel. The circuit breaker has been type tested in excess of 100 000 no-load mechanical operations without discernable component wear. The combination of magnetic actuators with long-life vacuum interrupters has resulted in circuit breaker life that was previously not possible. Further features include a low component count, reliability and minimal maintenance. including 1 250 A to and including 25 ka for 3 seconds BIL: 95 kv Type SBV24 This version is for 22 kv indoor utilisation and is of single busbar configuration. Circuit and busbar earthing via the circuit breaker are available options. The operating mechanism allows for hand charged spring or motor charged spring application. The mechanism design allows for the provision of the following features: second shunt trip facility under voltage (no-volt) trip facility direct acting (series) trip facility. 24 kv including 1 250 A to and including 25 ka for 3 seconds. BIL: 125 kv Type SBV-C These are fused vacuum contactors mounted on withdrawable carriages and are extensible on SBV3 and SBV4 switchgear. A manually operated cable discharge switch is an available option. Operating mechanisms are electrically held or mechanically latched options. Mechanical life of the vacuum contactors is in excess of 3 x 10 6 operations; electrical endurance in excess of 10 6 operations. Fused contactors have an advantage over circuit breakers in that the fuses greatly limit the magnitude and duration of short-circuit currents. Where the equipment is used in switching of motors, cables can be sized to carry load and starting currents only. Possible fault damage to motors can thus be restricted. (of contactor unit only) including 400 A Rated short circuit capability: 4 ka BIL: 75 kv

Internal arc testing of MV switchgear A major hazard of electrical medium voltage installations is the danger of an internal arc fault. The most common causes of an internal arc fault are tools left on the busbars after the initial installation or during maintenance, and binding wire used during commissioning tests, not having been removed prior to energising. An internal arc condition constitutes a potentially dangerous situation for the operator. Internal arc testing requirements were initiated by the German PHELA organisation. A procedure for internal arc testing was then developed, resulting in Appendix A of the IEC 60298 standard. Arc duration of 0,1 second is considered sufficient to prove the operation of pressure relief devices. Internal arc faults are normally simulated by a thin copper wire of approximately 0,5 mm in diameter stretched across two or more phases inside the various switchgear compartments, and in the case of segregated phase conductors, SBV3 double busbar switchpanel after internal arc test. between one phase and earth. All the relevant compartments must be individually tested to ensure the integrity of the complete switch panel, not just one particular section. For the effects of the explosion to be monitored under actual conditions, two walls, a ceiling and the floor are required to be simulated. As operator safety is of prime importance, indicators are positioned both horizontally and vertically in metal racks 300 mm from the switchgear being tested. The above indicators are positioned front and sides, facing all the points where gas is likely to be emitted, and positioned in such a way that hot gas escaping in slant directions can be monitored. These indicators consist of metal frames covered with black cretonne cloth of 150 g/m². To successfully complete the internal arc tests the equipment needs to meet the criteria set out in IEC 60298 Appendix A as repeated below: 1 Whether correctly secured doors, covers, etc, do not open. 2 Whether parts (of the metal-enclosed switchgear and control gear), which may cause a hazard, do not fly off - including large parts or those with sharp edges, e. g. inspection windows, pressure relief flaps, cover plates, etc, made of metal or plastic. 3 Whether arcing does not cause holes to develop in the accessible external parts of the enclosure as a result of burning or other effects. 4 Whether the indicators arranged vertically do not ignite. Indicators that ignite as a result of paint or stickers burning are excluded from this assessment. 5 Whether the indicators arranged horizontally do not ignite. Should they start burning, the assessment criterion may be regarded as having been met if proof is established that the ignition was caused by glowing particles rather that hot gases. Highspeed camera pictures should be produced in evidence. 6 Whether all the earthing connections are still effective. It is advisable to record the tests in a high-speed video of up to 1 000 frames per second in order to analyse the physical phenomena. The ever increasing safety needs call for switchgear manufacturers to comply with international and national standards. Internal arc fault testing in accordance with IEC 60298 The design of the SBV range of vacuum switchgear commenced in 1978. Even at that early stage the importance of internal arc fault venting and safety was recognised. The design of the horizontal withdrawable switchgear was chosen so as to incorporate top venting. Following Alstom s success at KEMA in 1997 when the SBV4 was successfully internal arc fault tested for 20 ka at for 0,1 second, more onerous tests were carried out at the SABS high power laboratory. The tests provided for side access in addition to front access and the internal arc was for 25 ka with a duration of 0,2 sec. Internal arc classification in accordance with IEC 62271-200 The introduction of IEC 62271-200 and internal arc classification (IAC) lead to Alstom enhancing its proven SBV range of circuit breakers (i.e. SBVE). The SBVE range is presently classified as BFL-AR 25 ka 0.2 sec in accordance with IEC 62271-200. Development and testing with SBVE is ongoing, ensuring safer and more reliable products. 5

1 2 3 4 5 6 1 SBV3 switchgear fitted with 2 500 amp busbar trunking to fit through fire wall 2 SBV4 switchboard with 2 000 A incomers 3 SBV5 circuit breaker carriage 4 Special purpose busbar trunking 5 SBV4/SBV4C switchboard during inspection 6 SBV24 switchboard being commissioned on site. 6

ALSTOM SWITCHGEAR Head office 2 Magnet Road Knights 1413 P O Box 13024 Knights 1413 Tel: (011) 820-5111 Fax: (011) 820-5210 E-mail: sginfo@alstom.co.za BRANCH OFFICES BLOEMFONTEIN PRETORIA CAPE TOWN 20 Lombard Street 449 Skilder Street 12 Hawkins Avenue Hilton 9300 Silvertondale Epping Industria No 1, 7460 P O Box 914 P O Box 1304 P O Box 276 Bloemfontein 9300 Silverton 0127 Eppindust 7475 Tel: (051) 448-1417 Tel: (012) 804-0551 Tel: (021) 532-2000 Fax: (051) 448-7104 Fax: (012) 804-1596 Fax: (021) 532-2013 PORT ELIZABETH DURBAN WELKOM 200 Kempston Road 70 Edwin Swales VC Drive 29 10 th Street Sidwell Rossburgh 4094 Voorspoed 9459 P O Box 3503 P O Box 922 P O Box 515 North End 6056 Durban 4000 Welkom 9460 Tel: (041) 451-5641 Tel: (031) 465-4170 Tel: (057) 355-2451 Fax: (041) 451-5650 Fax: (031) 465-4189 Fax: (057) 396-2155 NELSPRUIT POLOKWANE JOHANNESBURG C/0 Kragbron & Bester Street 115 Blaawburg Street 4 Branch Road Nelspruit 1201 Ladine 0750 Driehoek Germiston 1401 P O Box 785 P O Box 5908 PO Box 678 Nelspruit 1200 Polokwane 0750 Germiston 1400 Tel: (013) 753-2121 Tel: (015) 293-0920 Tel: (011) 878-3000 Fax: (013) 753-2130 Fax: (015) 293-0408 Fax: (011) 878-3010 STEELPOORT Building 1 Tweefontein Farm Steelpoort Ext 10 PO Box 786 Nelspruit 1200 Tel: (013) 230-3251 Fax: (013) 230-5253 RUSTENBURG Ruby Sands Road Memorial Park Rustenburg PO Box 20610 Protea Park Rustenburg 0300 Tel: (082) 317-4783 Fax: (012) 804-1596 7

Alstom Medium Voltage Switchgear 2 Magnet Road, Knights, 1413 P O Box 13024, Knights, 1413 Tel: (011) 820-5111 Fax: (11) 820-5122 email: sg.info@alstom.co.za