GUE, GUB Junction Boxes

Similar documents
EDS / EFS Series Control Stations

EDS / EFS Series Control Stations

STB Series Enclosures

Lighting Accessories Hazardous and Non-hazardous

Myers Hubs. The broadest, most complete offering for terminating Rigid/IMC to a box or enclosure

FLB Series Circuit Breakers and Enclosures

TMC CableReady Connectors For Jacketed Metal Clad Cable TMC For Non-Hazardous Locations

Cable-Gard Static Discharge Reels

THERMAL INSTRUMENT CO. 217 Sterner Mill Road, Trevose, PA Telephone No. (215) FAX No. (215)

8146/5 Series Breaker Panelboards

ELECTRIC METERING COMMERCIAL & INDUSTRIAL

FITTINGS: CAST DEVICE BOXES. Applications. Illustrated Features

EXLUX ECOLUX C-LUX LIGHTING. Explosion Protected Fluorescent Lighting Fixtures for Hazardous and Corrosive Applications

Sports and High Mast Lighting Poles Phone: (866) Fax: (817)

ELECTRICAL SERVICE REQUIREMENTS FOR MOBILE HOME DEVELOPMENTS

18 AWG thru 8 AWG Not greater than 100/30 100/30. 6 AWG thru 1/0 AWG Not greater than 200/60 100/30

Scepter PVC Molded Junction Boxes

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles

Scraper Passage Indicator. Electrical Indicator. Features

Scepter PVC Molded Junction Boxes

Weatherproof Products

METER REQUIREMENTS GENERAL REQUIREMENTS SECTION D

Type 1, 3, & 3R Enclosures

Plugs and Receptacles

All work must conform to the National Electric Code, latest edition, and all other applicable codes and regulations.

James M. Pleasants Company

Metallic and Non-Metallic Air Conditioning Disconnects. A Complete Family of. Disconnects with Exclusive Time Saving Features

Ammeter / Voltmeter Series 8402, 8403, 8405, 8404

Conduit Fittings & Accessories Directional Drilling Conduit Utility Duct Telephone Duct Residential Boxes

Ammeter / Voltmeter Series 8402, 8403, 8405, 8404

Cable Supports. Requirements for Cable Supports in the National Electrical Code reads as follows:

POINT OBSTRUCTION LIGHTS POL EX LED v5 HAZARDOUS LOCATION

Stainless Steel and Mild Steel Enclosures. Stainless Steel and Mild Steel Enclosures

SERVICE ENTRANCE - UNDERGROUND Single & Three Phase 200, & 320/400 Amp

% ^ ) 0.55 W Low Power Solenoid Valves Aluminum, Brass, or Stainless Steel Bodies 1/4" to 1" NPT. 2/2 3/2 4/2 5/2 5/3 SERIES Low Power

Motor Accessories. C-Face Kits for Field Conversion NEMA AC Motors

DuroSite Series LED High Bay for Indoor and Outdoor Industrial Applications. Patent Pending

Section 10 Electric Switchboards: 0 Through 600 Volts

PAGE/PARTY. Solutions. GAI-Tronics Page/Party. communication systems. provide paging and. party-line capabilities... two important plant

SECTION SIGNAL WIRE AND CABLE

Wiser Panel Meter, Model Number WISERCTPM200 Installer s Guide

Nelson MI Cable is a high performance, industrial grade heat tracing cable used for applications requiring:

Terminal Boxes Series 8146

AC METRIC (IEC) MOTORS THREE PHASE

Electrical Code Regulation

Explosion-Proof Electric Unit Heaters

AutoDome Easy II. VEZ Series. Mounting Manual

D-13. temporary / mobile power. for harsh & hazardous (classfied) locations. Construction Demolition Maintenance Turnarounds Shutdowns

HIGHLAND VALLEY SUPPLY, INC STANDARD TERMS AND CONDITONS OF SALE

General Accessories Hardware

RayClic Connection System Installation Instructions

High Temperature Acceleration System Bently Nevada* Asset Condition Monitoring

Dialight. Vigilant LED High Bay - UL for Indoor and Outdoor Industrial Applications

JIC CONTINUOUS HINGE BOXES

SECTION COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here)

Fabricated Drainage Products

PVC Pipe PVC SCHEDULE 40. Nominal Pipe Size (in.) 1/8. Average I.D. O.D.

CONTROL PANEL INSTALLATION INSTRUCTIONS. Single Phase Simplex Page Phase Simplex Page 8-13

Hazardous location controls and apparatus. Getting you closer. ACE series explosionproof variable frequency drives

Powertite Series Pin and Sleeve Receptacles, Connectors and Plugs

Heating Cable. Construction

Andersen Electric Window Opener for Andersen Awning and Roof Windows

MOBILE HOME SERVICE REQUIREMENTS GAS

ELECTRICAL GUIDELINES FOR SINGLE-FAMILY HOME OWNERS:

Mini USB and USB 2.0-IP67 Connector System

Electrical Service Guidelines

HOUSTON COMMUNITY COLLEGE HCC ALIEF CAMPUS MAIN BUILDING, FIRST, SECOND & FOURTH FLOORS RENOVATION ISSUE DATE:

Vigilant LED High Bay for Indoor and Outdoor Industrial Applications

RESIDENTIAL ELECTRICAL REQUIREMENTS (REVISED 3/28/2008) PERMIT REQUIREMENTS:

TYPICAL WIRING OF METER SOCKET FOR SINGLE PHASE, THREE WIRE OVERHEAD SERVICE

Pump_TM016. Local Display. 4-20mA. PLC/DCS Case 1. Relay Output Module. 4-20mA. Modbus. Optional. Case 2. Pump. Pump PT371 PT373 PCM370

AMERICAN FITTINGS. Corporation. SPEC-grade. Rigid-IMC Connectors Compression Type - (No Thread)

March 14, Installation of Bay, Bow and Garden Windows

High Performance Visible Laser Diode Scanners

Washer, Electrical Equipment Bond. WEEB Patent Pending INSTALLATION INSTRUCTIONS. For Kinetic Solar K-Rack only

DuroSite TM Series LED High Bay. for Industrial & Commercial Applications.

Model 362A AURORA. 340A/360A Series SINGLE STAGE END SUCTION PUMPS.

CABLE GLANDS AND CONNECTORS FOR THE IEC & NEC WORLD ATEX 95 & BEYOND ATEX 95 CMP PRODUCTS. Triple Certified

Generator DoCKInG StatIonS

PLUGS & RECEPTACLES. INNOVATIVE EXPLOSION PROTECTION by R. STAHL

TorqPlus TM Electric Valve Actuators and Controls

The National Armored Cable Manufacturers Association Presents. Installation Standard for Types AC and MC Cables

Linear Luminaire for Fluorescent Lamps Series EXLUX 6001

READ THIS MANUAL BEFORE PROCEEDING WITH THE INSTALLATION. FAILURE TO FOLLOW THE INSTALLATION INSTRUCTIONS MAY VOID YOUR WARRANTY!

Micro Motion Model D and DL Coriolis Flow and Density Meters

INDICATOR POST STYLE 2945 A TELESCOPING BARREL ASSEMBLY UL AND FM APPROVED

CABINET OPTIONS AND DESIGNATORS

SECTION UNDERGROUND ELECTRIC SERVICE

Explosion proof enclosures

Explosion Proof. Explosion Proof

INSTALLATION MANUAL ELECTRIC RANGE. Please read these instructions thoroughly before installing and operating the range.

NEI-30 VEI-30 Dinion Infrared Imager NEI VEI Series. Quick Install Guide

Power Distribution & Terminal Blocks

Operating Instructions

POINT OBSTRUCTION LIGHTS POL INCANDESCENT POINTSPEC SERIES

DTS-HAZ DTS-HAZ-DC. Installation Instructions. for use with Self-Regulating, Constant Wattage & Mineral Insulated Electric Heating Cables

Guidelines for Earthquake Bracing Residential Water Heaters

CONTENTS. Yale University Design Standards. Underground Electrical Duct Bank. A. Summary. B. System Design and Performance Requirements

2013 Edition. Flanged fittings 30"-64" NSF. industrial Applications, water & Wastewater. Certified to ANSI/NSF 61

Raceway and Boxes for Electrical Systems Page 1 of 7

Transcription:

E GUE, GUB Junction Boxes Cl. I, Div. & 2, Groups B, C, D Cl. II, Div., Groups E, F, G Cl. II, Div. 2, Groups F, G Cl. III NEMA 4*, BCD, 9EFG Ex d IIC T6, IP66 Ex d IIC, IP66, ATEX certified Explosionproof Dust-Ignitionproof Raintight Wet Locations Watertight E Applications: GUE, GUB series junction boxes are used in threaded rigid conduit systems in hazardous areas: To function as a splice box, pull box or equipment and device enclosure To house wiring Indoors and outdoors Features: Threaded construction throughout permits use in hazardous areas Bodies have thick walls so they can be factory or field drilled and tapped to meet NEC/CEC requirements for Class I hazardous areas Covers are provided with a neoprene "O" ring gasket to meet NEMA/EEMAC 4 requirements for a watertight seal Internal grounding lug provides a means to ground enclosed equipment Boxes are machined for field installed mounting plates GUB boxes are ATEX certified when ordered with Suffix SA ATEX (not available for GU and GUE) Certifications and Compliances: NEC/CEC: Class I, Division & 2, Groups B, C, D Class II, Division, Groups E, F, G UL Standard: 20 CSA Standard: C22.2 No. 0 ATEX: Ex d IIC, IP66 ATEX Certificate: PTB 0 ATEX 09 U Ex d IIC, IP66, ATEX certified Standard Materials: Bodies Feraloy iron alloy Covers copper-free aluminum Standard Finishes: Feraloy iron alloy GU, GUE, GUB0, GUB02 electrogalvanized and aluminum acrylic paint. All other boxes zinc chromate primer and aluminum acrylic paint Copper-free aluminum natural Options: Description Suffix Copper-free aluminum bodies and covers (GUB0, GUB02, GUB0, GUB06 only)... SA ATEX certified (GUB0 SA, GUB02 SA, GUB0 SA, GUB06 SA only)... SA ATEX Factory installed mounting plate for relays, terminal blocks, electrical devices, etc... MP Factory installed terminal blocks. Information on request Junction Boxes Without Hubs GU 4 /6" x 4 /6" x 4 " /6" cover opening GUE /6" x /6" x " /6" cover opening GUB0 6 " x " x " " cover opening GUB02 8" x 0" x " " cover opening GUB06 8 " x 0" x 6 " " cover opening GUB0 " 2" 8 /6" 9 " cover opening GUB00* 4" 8" " 2 " cover opening GUB 9" 2" 6 " 6 " cover opening GUB04 " x 2" x 8 /6 9 " cover opening GUB08 8 " 0" 6 /6 " cover opening *NEMA 4 not available on GUB00 and GUB. Order suffix SA ATEX. GUB00 and GUB are rated IP4. Please consult Modified Products for conduit entry arrangement options. provided are external. GUB00 listed for Class I, Div., Groups C & D only in Canada (CSA). Ordering Information: Junction boxes listed can be furnished with drilled and tapped conduit openings, subject to the limitations of maximum opening, number and spacing shown in Tables, 2 and 4. To Order: Step Select the box required from photos at left and dimensional drawings on next page. Step 2 Select standard conduit arrangement from Table. Step Determine maximum size conduit opening required from Table 2 (consider conduit opening spacing from Table 4). Step 4 Select appropriate symbol for required drilled and tapped holes from Table. Example: Step box required GUB06 Step 2 arrangement 08 Step openings " at "a" and "c"; " at "b" and "d". Step 4 symbols are substituted and written in clockwise order starting with location "a". For this example: FCFC Complete Cat. No. is made up of three parts: Part box number; Part 2 arrangement number; Part symbols for conduit openings. For this example: GUB06-08-FCFC. When no opening is required at a particular location, use symbol "0" (zero). If none of the standard arrangements meet requirements, send a sketch showing junction box number with size and location of each opening desired. www.crouse-hinds.com US: -866-64-44 CAN: -800-26-002 Copyright 20 Eaton s Crouse-Hinds Business

GUE, GUB Junction Boxes E Ordering Information Table Arrangements of Drilled and Tapped Conduit Openings For other arrangements, send sketch and complete description Conduit opening arrangements shown in the illustration should meet the majority of requirements. These GUB junction boxes will be supplied with drilled and tapped openings up to the maximum size and number shown in Table 2. 08 09 0 Table 2 Maximum & No. of Drilled & Tapped Holes Top & Bottom (bb) Each Side (aa) Back Cat. # 2 4 2 4 2 4 Group D* GU GUE 2 2 2 GUB0 2 2 GUB02 2 2 2 2 GUB06 2 2 2 2 2 2 2 2 GUB08 2 2 2 2 2 2 2 2 GUB0 2 2 2 2 2 4 4 GUB04 2 2 2 2 2 4 4 GUB00 2 2 2 2 2 2 2 6 6 4 GUB 4 2 4 4 6 6 6 6 Group C GU GUE 2 2 2 GUB0 2 2 GUB02 2 2 2 GUB06 2 2 2 2 2 2 GUB08 2 2 2 2 2 2 GUB0 2 2 2 2 4 2 2 GUB04 2 2 2 2 4 2 2 GUB00 2 2 2 2 2 2 2 6 6 4 GUB 4 2 4 2 6 6 6 Group B GU GUE 2 2 2 GUB0 2 2 GUB02 2 2 2 GUB06 2 2 2 2 2 2 GUB08 2 2 2 2 2 2 GUB0 2 2 2 2 4 2 2 GUB04 2 2 2 2 4 2 2 GUB00 2 2 2 2 2 2 2 4 4 4 4 GUB 4 4 2 4 4 2 4 4 4 4 Table Drilled & Tapped Holes Symbol A B C E F 2 G 2 H J K 4 L none 0 *Group D chart is based on use of staggered unions. If adjacent unions are desired, additional spacing may be necessary. Sidewall and top and bottom sizes are based on all openings being in line. Backwall sizes are based on: two per side diagonal corners; four per side one in each corner; three per side triangular pattern with two on adjacent corners on long wall and third in center of opposite long wall. Conduit seals are required within " of all conduit entrances for Class I, Group C hazardous locations. Conduit seals are required within " of all conduit entrances for Class I, Group B hazardous locations. For ATEX, please consult Modified Products for conduit entry arrangement options. E www.crouse-hinds.com US: -866-64-44 CAN: -800-26-002 Copyright 20 Eaton s Crouse-Hinds Business

E GUE, GUB Junction Boxes Table 4 Conduit Spacings All types Type p q r s t v w x y GU GUE GUB0 2 /6 2 2 2 9 /6 GUB02 2 /6 2 2 /6 2 /6 2 2 /6 GUB06 2 /6 2 2 /6 2 /6 2 2 /6 GUB08 2 /6 2 2 /6 2 /6 2 2 /6 GUB0 2 /6 /6 2 /6 2 /6 GUB04 2 /6 /6 2 /6 2 /6 GUB00 4 4 6 4 2 4 2 /6 GUB 6 4 4 2 4 2 4 In Inches: 2, or 4 entrances for conduit opening spacings on top, bottom or sides, all types. E GUB 0, 02, 0, 06, 00, and. Dotted mounting feet are included on GUB 0, 00, and only. GU and GUE are provided with attachable mounting strap. Type a b c d e f g h j k l m n GU 4 /6 4 /6 /6 /6 4 9 /6 /6 2 4 GUE /6 /6 4 /6 4 /6 2 /6 4 GUB0 6 6 /6 4 4 /6 6 GUB02 8 0 9 8 9 4 4 /6 GUB06 8 0 8 8 9 /6 4 /6 GUB08 8 0 8 2 9 /6 4 /6 GUB0 2 9 0 9 0 2 /6 8 /6 6 GUB04 2 9 0 9 2 /6 8 /6 6 GUB00 4 /6 8 /6 2 6 6 6 /6 0 9 4 GUB 20 8 9 6 8 2 6 9 /6 8 Inside dimensions. For conduit liner ordering information, see page 860 24 www.crouse-hinds.com US: -866-64-44 CAN: -800-26-002 Copyright 20 Eaton s Crouse-Hinds Business

GUE, GUB Junction Boxes E Mounting Plate Table Mounting Plate GUE GUB Box Cat. # Mounting Plate Kit Cat. # a b c d e GU GU MPK 9 4 /64 GUE GUE MP K 9 4 /64 GUB0 GUB MP0 4 GUB02 GUB MP02 9 /6 6 /6 GUB0 GUB MP0 8 9 /6 /6 GUB04 GUB MP0 8 9 /6 /6 GUB06 GUB MP02 9 /6 6 /6 GUB08 GUB MP02 9 /6 6 /6 GUB00 GUB MP00 8 2 /6 /6 GUB GUB MP 4 4 For conduit liner ordering information, see page 860 E www.crouse-hinds.com US: -866-64-44 CAN: -800-26-002 Copyright 20 Eaton s Crouse-Hinds Business 2

E Threaded Covers for GUB Junction Boxes Cl. I, Div. and 2, Groups B, C, D Cl. II, Div., Groups E, F, G Cl. II, Div. 2, Groups F, G Cl. III NEMA B CD, 9EFG Explosionproof Dust-Ignitionproof Raintight Wet Locations Watertight E Applications: GUB and EPC threaded covers are used with GUB boxes in control systems in hazardous areas: Indoors and outdoors In three categories: Flat for normal use; furnished with standard GUB boxes Glass window to provide visibility of meter indications when used to enclose meters Domed for increasing volume of GUB to make it easier to splice and pull large conductors Features: Domed more suitable for use when splices of heavy conductors are made and enclosed, since the conductors may be pulled in with the ends outside the box. After the splices are made, they do not have to be crowded back into the box Glass window has maximum diameter glass to give best visibility. In selecting, the diameter of the meter face should match or be slightly smaller than window diameter Certifications and Compliances: NEC: UL Standard 20 GUB00, -002, -00, -4, -0, EPC20, EPC2 Class I, Division and 2, Groups B, C, D Class II, Division, Groups E, F, G All other covers: Class I, Division and 2, Group D Class II, Division, Groups E, F, G CEC: CSA Standard C22.2 No. 0 Class I, Division and 2, Group D Class II, Division, Groups E, F, G GUB covers are suitable for use in hazardous areas only when used with appropriate GUB series enclosures. Standard Materials: Copper-free aluminum Standard Finishes: Natural Bodies are grouped by size of cover opening and take any of the covers shown in the group. Check certifications and compliances for specific hazardous area ratings for each catalog #. GUB flat cover GUB glass cover GUB dome cover Ordering Information Flat Glass Window Dome Cover Body Cover Cat. # Cover Cat. # Cat. # Nominal Depth GUB0 GUB00 GUB00 GUB4 4 GUB0 0 GUB02 GUB06 GUB08 GUB002 GUB008 GUB26 6 GUB0 GUB8 0 GUB04 GUB00 GUB009 GUB6 GUB00 EPC20 EPC2 GUB EPC2 Specify body and conduit openings in normal manner (see page 2) and state Cat. No. of cover required. In Inches: Flat Covers Thread Cat. # a b d GUB00 6 /6 2-2 GUB002 /6 /6-2 GUB00 /6 2 9-8 EPC20 2 2.660-8 EPC2 9 /6 6.90-8 Dome Covers GUB with dome covers Glass Covers Glass covers Window Opening Thread Cat. # a b c d GUB00 6 /6 /6-2 GUB008 /6 2 /6 4-2 GUB009 /6 /6 6 /6 9-8 For C Cat. # a b GUB02 GUB06 GUB08 all others d GUB4 /6 2 4 /6 4 GUB0 /6 9 4 /6 0 GUB26 6 4 6 GUB8 8 8 6 0 GUB6 8 6 EPC2 9 /6 9 /6 8 6 9 /6 EPC26 9 /6 4 9 /6 8 9 /6 26 www.crouse-hinds.com US: -866-64-44 CAN: -800-26-002 Copyright 20 Eaton s Crouse-Hinds Business