Y8150 Fresh Air Ventilation System, W8150 Fresh Air Ventilation Control



Similar documents
Installation Guide. VisionPRO. TH8000 Series. Need Help? This manual covers the following models. System Types

Installation Guide. Prestige IAQ with Equipment Interface Module. RedLINK to Equipment Interface Module. RedLINK to TrueZONE Wireless Adapter

T7079A,B Solid State Remote Temperature Controllers

Installation Guide. Programmable Thermostat TH6220D

Installation Guide. LR-HWLV-HVAC TouchPRO Wireless. System Types

Install Guide 3M-50. Caution. Caution

UV100A Ultraviolet Air Treatment System

T8000, T8001 Programmable Thermostat

Alerts and Delta T Diagnostics with the Prestige 2.0 IAQ Thermostat

, User s Manual

PRODUCT PRODUCT CODE TECHNICAL INSTRUCTIONS PAGE

Installation Instructions

INSTALLATION INSTRUCTIONS COMMERCIAL ROOM VENTILATORS WITH EXHAUST

INSTALLER S & OWNER S MANUAL

TR21, TR22, TR23, and TR24 Wall Modules

TAC I/NETTM MR-VAV-AX. Application Specific MicroRegulator TM

Roof Top Air Conditioner INSTALLATION AND OPERATING INSTRUCTIONS

Installation Instructions

Emergency Heat slide switch on the panel or an external switch. Do not use the panel switch or the external switch if Dip switch #4 is set to HP.

Install Guide CT100. Caution. Caution ENGLISH. disconnect the power supply before beginning work.

Wireless and Prestige Comfort Systems. Frequently Asked Questions Guide

Safety & Installation Instructions

Installation Instructions

T7560A,B,C Digital Wall Module

RESIDENTIAL THERMOSTATS CLIMATEMASTER

Install Guide CT101. Caution. Caution

its ELECTRIC POSITION for electric heat, or set the units fan control appropriately to ELECTRIC or another appropriate setting.

DUCT SMOKE DETECTOR D4120

Circuit breaker panel. Power supply for condensing unit. Power supply for furnace. Air handler (Furnace)

Communicating Wall Control Installation Manual TSTAT0101SC

Table of Contents. 1 - Specifications Installation Wiring User controls...7

SERVICE MANUAL 12VDC WALL THERMOSTAT AIR CONDITIONING SYSTEMS ROOFTOP UNITS ONLY

SERVICE MANUAL FOR 12 VDC WALL THERMOSTAT AIR CONDITIONING SYSTEMS ROOF TOP UNITS ONLY

WON0502-B INSTALLATION INSTRUCTIONS FOR ELECTRIC FURNACES. Bulletin / March 2013

HVAC-32A. Operation Manual. Specifications. Digital Multistage Air Conditioning Controller with inbuilt Outside Air Economy function

T841A Heating-Cooling Heat Pump Thermostat

Radiant Temperature Sensor TY7321

USER MANUAL WARNING! CONTENTS MODEL 1 SPECIFICATIONS READ ALL INSTRUCTIONS BEFORE PROCEEDING. Non-Programmable Single Stage Heat/Cool Thermostat

Cooktop Low-Profile Ventilation Hoods

Exhaust Calculation Booklet

T822, TS822 Heating/Cooling Thermostats

Installation, operation and maintenance manual TX 35A

HVAC Processes. Lecture 7

W7212, W7213, W7214 Economizer Logic Modules

Air Conditioner Water Heater - A Product of HotSpot Energy LLC

AIR CONDITIONING SYSTEM 1. FFH SPECIFICATION AIR CONDITIONING SYSTEM RODIUS

Operation and Installation Manual. Max Series

Drayton Digistat +2RF/+3RF

CONTROLS KITS AND ACCESSORIES /2014 Supersedes10/2014

T 3 Series VAV Diffusers Analog Diffuser Steel Square Panel Horizontal Pattern Model: T 3 SQ

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W

A/C-HEATER SYSTEM - AUTOMATIC

HE220A,B and HE260A,B Bypass Flow-Through Humidifier

Installing the Tracer ZN517 Unitary Controller Ordering number: ,

Installer Guide smart connect

AIR CONDITIONER & HEAT PUMP DIGITAL CONTROL FOR DUCTED SYSTEM INSTALLATION AND OPERATING INSTRUCTIONS

Fan Coil EC Motor Control

Nest Learning Thermostat Pro installation & configuration guide

NEBB STANDARDS SECTION-8 AIR SYSTEM TAB PROCEDURES

Air conditioning, electrical testing

Heater and Air Conditioner, Blend Air System, Troubleshooting 83.06

BC & BCH SERIES INDOOR / OUTDOOR INSTALLATION

HEAT RECOVERY VENTILATORS MODELS 90H-V ECM HRV, 90H-V+, 60H-V+ AND ENERGY RECOVERY VENTILATOR MODEL 90H-V ECM ERV

HEAT HEAT COOL HEAT PUMP COOL

R22. K Control. Indoor Unit. Nomenclature. Compatibility PL H 3 G K H B. Unit style Heat Pump Horse Power

HEAT PUMP PROGRAMMABLE THERMOSTAT

T-100-R Installation Guide

SC Installation, Operation & Application Guide

HVAC Simplified Approach Option

Honeywell CT3500/CT3595 PROGRAMMABLE THERMOSTAT

F50F Duct Mounted Electronic Air Cleaner

Installation Instructions

Operating Manual. Prestige THX9000 Touch-screen Thermostat Thermostat à écran tactile Termostato con pantalla táctil

T6570, T8570 Series Digital Fan-Coil Thermostats

Home Owners Guide HR SERIES HEAT RECOVERY VENTILATOR (HRV) Models HR100V, HR160H & HR220H RESIDENTIAL USE ONLY HR160H & HR220H

Thermo Top - Troubleshooting Tree

ModPac II 1 to 5-Ton Vertical Wall Mount Air Conditioners Models AVPA

Subpart 1. Installation. All plumbing systems must be. installed and tested according to this chapter and chapter 4715,

WHITE-RODGERS COMFORT-SET 90 SERIES

Heating and Cooling Basics Thermostat Control

Solid Core and Split Core Adjustable Current Status Switches CSS-O, CSS-C; CSP-O, CSP-C

USER S MANUAL HSC-24A

INSTALLATION INSTRUCTIONS

Y7230A CO 2 Alarm System

Section 7. Evaporator thermistor. Under-and-over pressure safety switches. Connections to the ECU

N20xxA, N34xxA NON-SPRING RETURN DIRECT-COUPLED DAMPER ACTUATORS FOR FLOATING AND 2-POSITION CONTROL

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W

HVAC Checklist - Long Form

Variable Air Volume - VAV

SERVICE INSTRUCTION R410A. SPLIT TYPE ROOM AIR CONDITIONER Universal Floor / Ceiling Duct / Cassette Wall Mounted / Floor type INVERTER MULTI

User Manual THR840DUK Digital Thermostat

OWNERS MANUAL. PAC 210 U Portable Windowless Air-Conditioner

VC Series Zone Valves BALANCED 2-WAY AND 3-WAY HYDRONIC VALVES

Ducoterra Radiant Heating Panel Installation Manual

QUICK INSTALLATION GUIDE

REFRIGERATED TYPE COMPRESSED AIR DRYERS INSTRUCTION MANUAL. For Sales & Service please contact:

Digi-Motor Installation Guide

Portable Evaporative Air Cooler. OWNER S MANUAL Read and save these instructions before use. Model: CL30XC

Transcription:

Y850 Fresh Air Ventilation System, 850 Fresh Air Ventilation ontrol PODUT DATA FEATUES APPLIATION The Y850 Fresh Air Ventilation System, 850 Fresh Air Ventilation ontrol provide fresh air to a home. The control operates a fresh air intake damper and, when necessary, activates the main blower to efficiently meet ASHAE ventilation rates. Designed to help meet local ventilation codes and standards, including ASHAE 62.2-2003 standard, Ventilation and Acceptable Indoor Air Quality in Low-ise esidential Buildings. Microcontroller optimizes the air delivery schedule to make efficient use of normal run times. Easy-to-use input dials allow customized ventilation for each installation. Test mode that includes immediate feedback to installer to confirm that air delivery requirements of selected ventilation standard are being met. Economical supply-only ventilation; works with forced air system. an be used with other equipment, such as an HV/ EV, for balanced ventilation. IMPOTANT Please read these instructions and keep them in your records. 68-0282-0

Y850 FESH AI VENTILATION SYSTEM, 850 FESH AI VENTILATION ONTOL SPEIFIATIONS Y850 includes: 850A Fresh Air Ventilation ontrol. EAD6 Fresh Air Damper. AT20B Transformer. Mounting hardware for control. Homeowner information label. 4-3/6 (06) -/4 (32) 850 includes: 850 Fresh Air Ventilation ontrol. Mounting hardware for control. Homeowner information label. ontrol (850A): Power Supply: 20-30 Vac, 60 Hz. Power onsumption: 3.5 VA at 24 Vac. Thermostat Fan Load: 0 ma resistive at 24 Vac. Thermostat Heat Load: 0 ma resistive at 24 Vac. emote Terminals: 0 ma resistive at 24 Vac. elay ontacts: Fan:.5A full load, 7.5A locked rotor at 24 Vac. Damper: 0.6A inductive, 3.A locked rotor at 24 Vac. Auxiliary: 0.5A inductive, 2.5A locked rotor at 24 Vac. Damper (EAD6): 24 Vac, 2 VA, 60 Hz. Operation: Power-open, spring-closed. Diameter: 6 in. Transformer (AT20): Input: 20 Vac. Output: 27 Vac open circuit, 24 Vac full load at 20 VA. Mounting: Foot mounted. 850A Ventilation ontrol dimensions in in. (mm). 3-3/8 (86) 6 (52) -/2 (38) 3-/2 (89) 5-3/4 (46) M9988 Temperature: -20 F to 60 F (-29 to 7 ). Humidity: 5 to 90% H, noncondensing. Input Setting anges: Bedrooms: 2-5. Area: 000-4600 sq ft. Vent Airflow: 40-60 cfm. omposite Setting esolution: +/- 2% of ASHAE 62.2-2003, recommended ventilation for single-system setup. AT20B Approvals: UL omponent ecognized: lass 2, File No. 488. Location: Device can be installed in unconditioned space. Multiple devices can be installed when operating multiple systems. EAD6 Fresh Air Damper dimensions in in. (mm). 3/6 (5) 2-3/6 (7) -7/8 (48) 8 (203) 3/6 (5) M9989 5/6 (24) (25) -3/4 (44) Dimensions: See device dimension diagrams. -5/8 (4) /6 (2) M22022 AT20B Transformer dimensions in in. (mm). 68-0282 0 2

Y850 FESH AI VENTILATION SYSTEM, 850 FESH AI VENTILATION ONTOL 2 3 4 5 6 7 8 9 0 ON XFM EMOTE AUX DAMPE 20 9 8 7 6 5 4 2 BEDOOMS AEA (SQFT) VENT AIFLO (FM) 3 M9990 850 QUIK GUIDE No. Name Description Function Equipment fan Allows 850 to pass thermostat calls and, when necessary, turn on system fan for ventilation. This should be the only connection to G on the equipment. 2 24 Vac cooling system Provides power to terminal to operate system fan, when necessary. power 3 24 Vac cooling system Allows 850 to monitor when system fan is energized. common 4 24 Vac heating system Allows 850 to monitor thermostat heat calls when is energized. common 5 Heating Allows 850 to monitor when heating is energized. 6 Thermostat (or other control) fan terminal 7 Switch On (optimal ventilation) Override Off (emote Only) Allows 850 to monitor when is energized. All external equipment that controls the system fan should be wired to this terminal. On (optimal ventilation) 850 ventilates, based on control settings. Override 850 runs ventilation continuously. Off (emote Only) 850 supplies ventilation only when there is a remote call. 8 Light Green Indicates device is powered and operating normally. Used in Test Mode to signal if dial settings meet chosen standard. 9 Light ed Indicates the device is not operating normally. Used in Test Mode to signal if dial settings do not meet chosen standard. 0 DIP Ventilation limit hoose between 60% (default) and 00% maximum fan run time allowed by 850 for ventilation. DIP2 Ventilation standard hoose between ASHAE 62.2 (default) and 62-999 ventilation standards. 2 BEDOOMS Number of bedrooms Used to calculate amount of ventilation necessary. 3 AEA (SQ FT) 4 VENT AIFLO (FM) Square footage of conditioned space Air delivery rate through fresh air duct. Used to calculate amount of ventilation necessary. Used to calculate amount of ventilation necessary. 5 Test Test button 850 checks dial and switch settings, activates ventilation for up to three minutes and provides feedback to validate if chosen standard can be met. 3 68-0282 0

Ventilation ontrol ontinuous (emote Only) Ventilation ontro l Y850 FESH AI VENTILATION SYSTEM, 850 FESH AI VENTILATION ONTOL No. Name Description Function 6 EMOTE emote switch (two terminals) 24 Vac powered contacts allow a remote switch closure to call for ventilation. 7 AUX Auxiliary (two terminals) 24 Vac dry contacts allow 850 to control an auxiliary device, such as exhaust fan or HV/EV, with a call for ventilation. 8 DAMPE Damper (two terminals) 24 Vac powered contacts control fresh air damper. 9 XFM 24 Vac ventilation control Supplies power to 850 and damper from transformer provided. common 20 XFM 24 Vac ventilation control Supplies power to 850 and damper from transformer provided. power INSTALLATION A fresh air duct and damper must be installed between the outdoors and the return side of the equipment. The 850 control will be mounted near the system and wired between the thermostat and the fan control. You will need 850 Fresh Air Ventilation ontrol. damper. transformer. insulated ductwork. outdoor weather hood. starting collar. access to 20 Vac power. airflow measuring tool. TIPS: To meet ASHAE 62.2-2003, system must have at least a MEV 6 filter installed. In cold climates, balanced ventilation is recommended. An exhaust fan or heat recovery ventilator can be used. Humid climates may require additional dehumidification equipment. hoosing a location hen choosing locations for equipment, duct connections, and fresh air intake, be sure to consult local code requirements. Device Number omponent Location Fresh air intake Install away from known sources of pollutants such as auto exhaust, dryer vent exhaust or chimney smoke. 2 Fresh air duct Install between weather hood and upstream of equipment filter and downstream of any duct-mounted sensor. 3 Damper Install damper in fresh air duct, where convenient. Optionally, install heat recovery ventilator. 4 ontrol Locate the control for convenient access and for easy wire routing. 5 Transformer Locate where convenient for line voltage connection. 6 Filter Locate filter downstream of fresh air intake. TYPIAL ATTI INSTALLATION 2 3 4 6 5 2 3 3 2 HV/EV 4 4 TYPIAL BASEMENT INSTALLATION TYPIAL HV/EV INSTALLATION 6 6 M9993 68-0282 0 4

Y850 FESH AI VENTILATION SYSTEM, 850 FESH AI VENTILATION ONTOL Installing fresh air damper, ducting, and control. Disconnect power from system. 2. Install the weather hood, ducting, and damper following local practices. Be sure all duct and insulation seams are tightly sealed. 3. Mount the transformer and control. TIPS: In general, larger ducting allows higher airflow, minimizes additional fan run time and may be needed for larger homes. Installing a damper directly to the return duct may be convenient to support the damper and reduce ducting. Fresh air connection should be downstream of sensors (such as a humidistat) in return air plenum. The EAD6 end stops can be used to reduce the amount of airflow in the duct. To prevent complete opening, loosen (but do not remove) the wing nut and move the upper lever until the desired position is reached. Tighten the wing nut. Keep the lower lever in the position shown. iring the control AUTION Electrical Hazard. an cause personal injury or equipment damage. Disconnect power to all systems before beginning installation.. ire the control. See wiring diagrams in Fig. -0 as listed below. All wiring must comply with local codes, ordinances, and regulations. 2. eapply power to system and control. TIP: ontrol package allows wire routing through side slots and bottom openings. System Hookup Diagrams Fig. No. Page No. Single transformer, conventional 0 Dual transformer, conventional 2 0 Multi-stage, conventional 3 0 Heat pump without emergency heat 4 0 Heat pump with emergency heat 5 UPPE LEVE ING NUT LOE LEVE M2055 Accessory Hookup Diagrams Fig. No. Page No. iring with a P8900 Thermostat 6 iring with a remote switch/timer 7 iring to an HV/EV 8 iring an exhaust fan 9 iring a fan for a steam humidifier 0 2 5 68-0282 0

Y850 FESH AI VENTILATION SYSTEM, 850 FESH AI VENTILATION ONTOL Measuring airflow. Make sure all system air filters are clean and installed. 2. Push Test button: ontrol opens damper and turns on fan for three minutes. A red or green light is flashing; you can now measure airflow. 3. Follow instrument instructions for measuring airflow. TIPS: You can exit the test mode at any time by pressing the test button again. See onversion Table (located after wiring diagrams) for quick area and airflow setting conversions. For future reference, record the air flow on the inside of the device cover. Pitot Tubes and flow measuring stations are commonly used airflow measuring devices. About the control settings Dial Settings These settings allow the installer to customize the control to meet the ventilation requirements for the home. Ventilation Standard Building codes are different everywhere. The 850 Ventilation ontrol can be configured to operate based on: ASHAE 62.2. ASHAE 62-999 TIP: lear understanding of local codes and practices is required to make sure the ventilation system is installed and configured correctly. Generally, ASHAE 62.2 control method is recommended and can meet many existing local codes. ode/standard Setting General Ventilation ASHAE 62.2 equirements ashington State Energy ASHAE 62.2 ode anadian Building ode* ASHAE 62.2 Minnesota Energy ode 62-999 2002 International 62-999 esidential ode *In anada, interlocking exhaust equipment may be required for balanced ventilation. Ventilation Limit This setting determines the maximum amount of time that the fan runs for ventilation. 60% ASHAE 62.2 Ventilation Limit* 2 Ventilation Standard 00% 62-999 BEDOOMS M22009 Setting ventilation limit and ventilation standard. 68-0282 0 6

Y850 FESH AI VENTILATION SYSTEM, 850 FESH AI VENTILATION ONTOL Setting the control.... Be sure power is turned on. 2. Set the Ventilation Standard on the control. 3. Set the bedrooms dial. 4. Set the area (sq ft) dial. 5. Set the airflow (cfm) dial. 6. Press the test button and observe the lights: Green light is flashing. The dial settings meet the chosen standard. ed light is flashing. There is not enough fresh air delivered to meet the requirements of the selected standard. See Troubleshooting section. 7. ecord settings on the label inside the cover as shown in the diagram. TIPS: Ventilation control reads new dial setting only when test button is pushed or power is cycled. To ensure dial settings are read, push test button after any changes are made. For single bedroom homes, set the bedrooms dial to 2 (this may result in more ventilation than the minimum required). For homes having more than five bedrooms and only a single ventilation system, set the bedrooms dial to 5 (this may result in less ventilation than the minimum required). For conditioned square feet, set area (sq ft) dial to the nearest value. For airflow, set airflow (cfm) dial to the nearest value. Vaulted ceilings do not need to be considered when setting this control. For homes with multiple systems: Honeywell recommends a ventilation control and fresh air intake for each system. Measure ventilation airflow for each system independently. efer to Multi-system Setup Example for further details. 850A 00 Stat DMP DMP AUX AUX EM EM 24 VA XFM Damper EV/Fan Timer/Switch Date installed: 60% ASHAE 62.2 bedrooms Ventilation Limit* 2 Ventilation Standard 00% 62-999 Installer Test area (sq. ft.) ecord settings above airflow (cfm) 850A 00 DMP DMP AUX Stat AUX EM EM Honeywell Golden Valley, MN 55422 500059-00 ev. A 24 VA XFM Damper EV/Fan Timer/Switch Date installed: Ventilation Limit* 60% 00% ASHAE 62.2 2 62-999 Ventilation Installer Standard Test bedrooms area (sq. ft.) airflow (cfm) ecord settings above www.honeywell.com/yourhome Para español ver las instrucciones or call -800-468-502 *See Instructions Voir mode d'emploi en français inclus Patent Pending ustomizing the ventilation control. M999 7 68-0282 0

Y850 FESH AI VENTILATION SYSTEM, 850 FESH AI VENTILATION ONTOL EKOUT In this section, make sure the ventilation system is operating correctly.. On thermostat, set Fan switch to and System switch to Off. 2. Set any remote switches throughout the house in the Off position. 3. On the 850, set the control switch to Off (remote only). 4. Press Test button for two seconds to enter test mode: A light on the control begins flashing. The system fan comes on. The damper moves to the Open position. 5. Press the Test button again to exit test mode: No lights on the control are on. The system fan turns off. The damper returns to the closed position. 6. eturn the thermostat, ventilation control, and remote switches to the original settings. 7. efer to Troubleshooting section, if needed. TIP: 850 Ventilation ontrol automatically exits test mode after three minutes. TOUBLESHOOTING Problem Possible cause hat to do Flashing red light during test mode (The current settings do not meet the selected ventilation requirement) Flashing red light during normal operation No light on ventilation control when switch set to: On Override Off/ emote Only and a remote switch is on. fan does not come on after pressing Test button. Not enough airflow Measure airflow and check dial setting. See Problem: Not enough airflow. Ventilation on-time limit setting If the device is set to 60%: Set the ventilation control to 00% maximum on time. This allows the fan to run up to 00% of the time. It may be preferable to increase airflow. If the device is set to 00%: There is not enough airflow through the fresh air duct. Ventilation continues to occur according to the settings but chosen standard may not be met. Low voltage heck the voltage from the transformer for at least 20 Vac. If voltage is OK, replace 850 ontrol. If voltage is not OK, disconnect damper and remote switch connections and check again. If voltage does not return to at least 20 Vac, replace transformer. No power to control Verify 24 volt input to and terminals on ventilation control. heck wiring connections per appropriate system diagram and replace transformer, if necessary. Device malfunction ycle power off to control for ten seconds and recheck. If control does not recover, replace ventilation control. iring heck wiring connections per appropriate system diagram. system does not have power estore power to the system. 68-0282 0 8

Y850 FESH AI VENTILATION SYSTEM, 850 FESH AI VENTILATION ONTOL Problem Possible cause hat to do fan is running all the time Device is set to override Move switch to On position to allow for automatic operation. emote switch is on Adjust remote switch to desired position. Damper does not open during checkout or Damper does not close. ooling compressor comes on when there is no cooling call from the thermostat. Thermostat Fan switch is in On position system is running to satisfy heating or cooling requirements. Ventilation limit is set to 00% ventilation limit. Normal operation. Normal operation. Set ventilation limit to 60%. The control may not be able to meet the recommended ventilation requirements. Increase ventilation airflow through fresh air duct and adjust settings. Low ventilation air flow. See Problem: Not enough airflow. Incorrectly wired. heck wiring connections per appropriate wiring diagram. Transformer output. Verify 24 Vac applied to actuator. Damper actuator motor failure or mechanical failure. Manually open damper and verify free movement; damper should return to closed position when no power is applied. If damper moves freely but does not operate when 24 volts is applied, replace damper actuator. If damper does not move freely, replace fresh air damper. Incorrectly wired. heck wiring connections per appropriate system diagram. An isolation relay may be required when appliances are connected to the terminals on the ventilation control. (For an example, see wiring a fan for a steam humidifier diagram.) Not enough airflow Obstruction or duct size heck for obstructions in the fresh air duct and weather hood. heck for kinks in ductwork. Make sure all manual dampers are fully open. Make sure the stops on the EAD damper allow it to open fully. Increase duct size. Add a booster fan to the fresh air duct. NOTE: After any changes to the ductwork, repeat the Measuring Airflow section. 9 68-0282 0

Tue ake Tue ake AM AM DST DST oom oom System Heat Fan System Heat Fan Tue ake Tue ake AM DST oom AM DST oom System Heat Fan System Heat Fan Y850 FESH AI VENTILATION SYSTEM, 850 FESH AI VENTILATION ONTOL IING DIAGAMS onsult thermostat Installation Instructions for alternate terminal designations. 2 Y Y2 G Y G 850A 850A 2 Y Y2 G Y G M9996 M9994 Fig. 3. Multi-stage conventional system. Fig.. Single transformer, conventional system. Y G O HEATING OOLING Y G 850A 850A Y G O/B Y G NOTE: EMOVE FATOY INSTALLED JUMPE BETEEN AND ON 850. M9997 M9995 Fig. 4. iring heat pump without emergency heat. Fig. 2. Dual transformer, conventional system. 68-0282 0 0

Tue ake AM DST oom System Heat Fan ontinuous Off (emote Only) Service Ventilation ontrol ontinuous Off (emote Only) Service Ventilation ontrol ontinuous Off (emote Only) Ventilation ontrol Service Y850 FESH AI VENTILATION SYSTEM, 850 FESH AI VENTILATION ONTOL AT20 EAD-6 Y 2 E G O 850A 850A XFM FAN TIME Ventilation ontrol EMOTE AUX DAMPE M22000 Y 2 E G O/B Fig. 7. Using a remote switch or timer. M9998 Fig. 5. iring heat pump with emergency heat. AT20 H50/E50 850A EMOTE AUX DAMPE XFM EAD-6 NOTE: ONFIGUE P8900 SO ALL VENT POGAM SETTINGS AE OFF; THE VENT BUTTON ON THE P8900 THEN SEVES AS A EMOTE AND THE 850 ONTOLS BAKGOUND VENTILATION. Fig. 6. iring with a P8900. H HUM HUM VNT VNT 8900 M9999 850A Ventilation ontrol EMOTE AUX DAMPE XFM ED BLAK NOTES: BALANE THE HV/EV TO 60 FM O LOE. SET VENTILATO SPEED KNOB TO 0. EAD DAMPE NOT USED ITH HV/EV. AT20 Fig. 8. iring to an HV/EV. EAD-6 FAN TIME M2200 EXHAUST FAN 20 VA XFM 850A Ventilation ontrol EMOTE AUX DAMPE AT20 BLUE BLUE 8222 ED BLAK 20 VA L L2 FAN TIME M22002 Fig. 9. iring an exhaust fan. 68-0282 0

Tue ake AM DST oom System Heat Fan Y850 FESH AI VENTILATION SYSTEM, 850 FESH AI VENTILATION ONTOL ONVESION TABLE HE440 2 Y Y2 G FAN ED BLAK 8222 BLUE BLUE 2 Y Y2 G 850A M2202 Area Airflow sq ft sq m cfm lps 000 93 40 9 300 2 50 24 600 49 60 28 900 77 70 33 2200 204 80 38 2500 232 90 42 2800 260 00 47 300 288 0 52 3400 36 20 57 3700 344 30 6 4000 372 40 66 4300 399 50 7 4600 427 60 76 Fig. 0. iring fan for a steam humidifier. Multi-System Setup Example Total square feet and bedrooms should be proportionately split between the ventilation controls based on sq ft served by each system regardless of where the bedrooms are located. Example: 5,000 sq ft, six bedrooms: System : serves 3200 sq ft, two bedrooms. fresh air intake measured at 27 cfm. System 2: serves 800 sq ft, four bedrooms fresh air intake measured at 98 cfm. Set 850 for System : 300 sq ft, four bedrooms 30 cfm. Set 850 for System 2: 900 sq ft, two bedrooms 00 cfm. 6 in. duct (5.2 cm) Airflow 7 in. duct (7.8 cm) cfm fpm ms fpm ms 40 204.0 50 0.8 50 255.3 87.0 60 306.6 225. 70 357.8 262.3 80 407 2. 299.5 90 458 2.3 337.7 00 509 2.6 374.9 0 560 2.8 42 2. 20 6 3. 449 2.3 30 662 3.4 486 2.5 40 73 3.6 524 2.7 50 764 3.9 56 2.9 60 85 4. 599 3.0 mation and ontrol Solutions Honeywell International Inc. Honeywell Limited-Honeywell Limitée 985 Douglas Drive North 35 Dynamic Drive Golden Valley, MN 55422 Toronto, Ontario MV 4Z9 customer.honeywell.com U.S. egistered Trademark 2008 Honeywell International Inc. 68-0282 0 M.S. ev. 06-08