Switches for photovoltaic applications Switch-disconnectors OTDC and OTDCP

Similar documents
Breakers and Switches. Switches Switch-disconnectors OT, OETL, OTDC and OTM

SIRCOVER. Manual changeover switches from 125 to 3200 A. Changeover switches. Function. Advantages. The solution for.

Low Voltage Products. Switches Automatic Transfer Switches

Breakers and Switches. Switches Change-over, bypass and transfer switches

Electronic overload relay EF19 and EF45

Electronic overload relay EF65, EF96 and EF146

Low voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application.

Catalogue May EasyLine XLP Fuse Switch Disconnector pole

Thermal-Magnetic Circuit Breaker M1-..

Manual Motor Starter MS 116 up to 16 A Technical Data

Breakers and Switches. Quick selection tool Accessories for switch-disconnectors and DC-switch-disconnectors

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

FUSERBLOC. 20 to 1250 A Manual operation. 142 General Catalogue SOCOMEC. Fuse combination switches

PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV

Feed-through terminal block - SSK 110 KER-EX

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

ZS10 Screw Clamp Terminal Block

Tmax MCCBs. Molded case circuit breakers. Tmax

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & Instructions For Installation, Operation & Maintenance

48 SERIES Relay interface modules 10 A

Emergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN , VDE 0113 Part 1

Contractors Guide Central Inverter System Installation

pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2, /0.65/0.

Rotary Disconnect Switch Specifications

R.C.C.B. s two-pole LEXIC

Plug and Socket Devices CES 63 A Series 8579

Manual motor starter MS116

ZS4-SF1-T Screw Clamp Terminal Blocks For 5 x 20 and 5 x 25 fuses - with test socket

Single-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

HS5D. Miniature Interlock Switches First in. Head Removal Detection Function for Safer Performance. First in. the Industry.

ZS25 Screw Clamp Terminal Blocks Feed-through

Technical catalog - Edition SACE Tmax PV Adaptability, versatility and complete freedom continue

SPEEDFAX TM 2011 Disconnect Switches Contents

NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals

Breakers and Switches. Switches Automatic Transfer Switches

Block width on rail (mm) Standard block* is shown on blue background

1 pole, 16 A Screw terminal connection 35 mm rail (EN 60715) mounting. 2 pole, 8 A Screw terminal connection 35 mm rail (EN 60715) mounting

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

38 Series - Relay interface modules A

Phone: Fax: Web: info@clrwtr.com

ZS6-S Screw Clamp Terminal Blocks Disconnect with blade

Protection and Connection. EasyLine XLP Fuse Switch Disconnector pole

AF / AF09Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals

DRM75A 230V 20/100A DIN rail single phase two wire energy meter

Low Voltage Products. Change-over and transfer switches Rotary change-over and bypass cam switches

49 Series - Relay interface modules A. Features

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

The complete range of consumer switchboards and switchgear

How To Build A Low Voltage Capacitor Lvcp

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

RM4TG20 three-phase network control relay RM4-T - range V

38 SERIES. Relay interface modules A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.

PRODUCT GUIDE. SL Medium Voltage IEC Vacuum Contactors

Series 8146/5-V37 and Series 8150/5-V37

Plug and Socket Devices SolConeX 16 A Series 8570

38 Series - Relay interface modules A

Vario-Series Accessories

ZS4-S-T Screw Clamp Terminal Blocks Disconnect with blade - with test socket

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories

Application Switchgear for industrial and commercial applications. U e V AC 230/ (per pole)

7000 Series Buccaneer

V REG.-Nr , Z E Technical data 2-pole 4-pole Rated current 12 A 6 A SCHRACK. Accessories Miniature Relay PT. General Purpose Relays

Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protection

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

Technical catalogue. Modular DIN rail components Installation contactors

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

Installation. Smart-UPS VT MGE Galaxy Maintenance Bypass Panel kva 400 V

Quick Connect. quick - simple - efficient.

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Renewable energy. Inverters - Socomec G-1. Load break switches (Isolators) - Socomec G-2. Fuses - df G-3. Fuse bases.

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

WE-350 Series ¼ Turn Electric Actuator

34 Series - Slim electromechanical PCB relays 6 A. Features SERIES 34.51

Catalog. Modular DIN rail components Installation contactors

ELEKTROTEHNI KO PODJETJE Leskoπkova cesta 12, 1000 Ljubljana, SLOVENIA

Directory chapter 02 - DIN Power (to 6 A) Types D, E, F, FM, 2F, F9, interface connectors I/U Technical characteristics types D and E

Bimetallic Overload Relay Specifications

Secondary Unit Substations

D7 Series Standard and Full Featured. Standard DPDT 24V AC 120V AC 240V AC 12V DC 24V DC 120V AC 110V DC 240V AC 6V AC 6V DC 12V AC 12V DC 24V AC

IEC >>> IEC GUIDE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

Three-phase monitoring relay CM-PFE

Catalog. Arc Guard System TM TVOC-2

8146/5 Series Breaker Panelboards

FOSTCDR. Industrial Serial to Multimode Fiber Optic Converter PRODUCT INFORMATION B&B ELECTRONICS. Specifications Serial Technology

3RT1015-1BB41 CONTACTOR, AC-3 3 KW/400 V,

Jumper bar BJM. Assembled jumper bar BJD. Assembled jumper bar

12 Series - Time switches 16 A. Features

Installation. Smart-UPS VT and MGE Galaxy Maintenance Bypass Panel with Power Distribution (wall-mount) kva 208 V

Redundancy Module QUINT-DIODE/40

Medium Voltage Products. ZN1 12 kv arc-proof air-insulated switchgear for primary distribution

Low Voltage Disconnect Switches. NFPA79 and UL508A Industrial Machinery Operating Handle Requirements White Paper

KOLMA and IHDA Indoor type Cable Current Transformers Catalogue ABB Power Distribution ABB Transmit 1 KKOLMA 1 GB

Safety detection solutions

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

2011/2008/2005 NATIONAL ELECTRICAL CODE SOLAR PV CODE COMPLIANCE REFERENCE

Transcription:

Contact us ABB y Breakers and Switches P.. Box 622 I-65101 Vaasa, inland Phone: +358 10 22 11 ax: +358 10 22 45708 E-Mail: firstname.surname@fi.abb.com www.abb.com The technical data and dimensions are valid at the time of printing. We reserve the right to subsequent alterations. Catalogue TDC1GB 14-10 1SCC301021C0201 Breakers and Switches Switches for photovoltaic applications Switch-disconnectors TDC and TDCP

Switch-disconnectors TDC16...800 and TDCP16...32 Contents 4 Product overview 8 Technical data 11 Type designation key 12 TDC16 32 ordering information 12 TDC16 32, base mounted, IEC 13 TDC16 32, base mounted, UL 14 TDC16 32, door mounted, IEC 15 TDC16 32, door mounted, UL 16 TDCP enclosed switches, IEC 18 TDC100 800 ordering information 18 Single circuit, 1000 VDC, IEC 19 Single circuit, 1000 VDC, UL 22 Double circuit and load side combining, 1000 VDC, IEC 23 Double circuit and load side combining, 1000 VDC, UL 26 Triple circuit, 1500 VDC, IEC 28 Single and double circuit, 1500 VDC, IEC 29 Single circuit, 1500 VDC, UL 32 Side operated, Single circuit, 1000 VDC, UL 34 TDC16 32 accessories 38 TDC100 800 accessories 45 Dimension drawings 51 Index Switches for PV applications Contents 3

DC switch-disconnectors, front operated 16...800 A, IEC IEC 60947 TDC162 TDC163 TDC164 TDC100E02 TDC100E11 TDC252 TDC253 TDC254 TDC160E02 TDC160E11 TDC322 TDC323 TDC324 TDC200E02 TDC200E11 TDC250E02 TDC250E11 U e [V DC] 660 1000 1000 / 2x660 1000 1000 I e, DC-21B [A] 16 25 32 16 25 32 16 25 32 100 160 200 250 100 160 200 250 IEC 60947 TDC315E02 TDC315E11 TDC315EV12 TDC315E22 TDC315E33 TDC630EPP22 TDC400E02 TDC400E11 TDC400EV12 TDC400E22 TDC400E33 TDC800EPP22 TDC500E02 TDC500E11 TDC500EV12 TDC500E22 TDC500E33 Ue [V DC] 1000 1000 1500 1000 1000/1500 1000 I e, DC-21B [A] 315 400 500 315 400 500 315 400 500 315 400 500 315 400 500 630 800 DC switch-disconnectors, enclosed 16...32 A, IEC IEC 60947 TDCP16SA11M TDCP16S11M TDCP16SA21M TDCP16S21M TDCP16SA22_ TDCP16S22_ TDCP25SA11M TDCP25S11M TDCP25SA21M TDCP25S21M TDCP25SA22_ TDCP25S22_ TDCP32SA11M TDCP32S11M TDCP32SA21M TDCP32S21M TDCP32SA22_ TDCP32S22_ U e [V DC] 660 660 1000 1000 1000 / 2x660 1000 / 2x660 I e, DC-21B [A] 16 25 32 16 25 32 16 25 32 16 25 32 16 25 32 16 25 32 4 Product overview Switches for PV applications

DC disconnect switches, front operated 16...600 A, UL * ) UL508i ile E4466875 Base or DIN-rail mounting TDC16U2 TDC16U4 TDC16U6 TDC16US2 TDC16US4 TDC16US6 TDC25U2 TDC25U4 TDC25US2 TDC25US4 TDC32U4 TDC32US4 Rated Voltage [V DC] 600 600 600 600 600 600 Rated current [A] 16 25 16 25 32 16 16 25 16 25 32 16 UL508i ile E4466875 Door mounting TDC16UT2 TDC16UT4 TDC16UT6 TDC16UST2 TDC16UST4 TDC16UST6 TDC25UT2 TDC25UT4 TDC25UST2 TDC25UST4 TDC32UT4 TDC32UST4 Rated Voltage [V DC] 600 600 600 600 600 600 Rated current [A] 16 25 16 25 32 16 16 25 16 25 32 16 UL98B ile #E354681 TDC100U02 TDC100U11 TDC100U22 TDC100US02 TDC100US11 TDC100US22 TDC200U02 TDC200U11 TDC180U22 TDC200US02 TDC200US11 TDC180US22 Rated Voltage [V DC] 1000 1000 1000 1000 1000 1000 Rated current [A] 100 200 100 200 100 180 100 200 100 200 100 180 UL98B ile #E354681 TDC250U02 TDC250U11 TDC250U12 TDC250U22 TDC600UPP22 TDC320U02 TDC320U11 TDC320U12 TDC320U22 TDC400U02 TDC400U11 TDC400U12 TDC400U22 Rated Voltage [V DC] 1000 1000 1500 **) 1000 1000 Rated current [A] 250 320 400 250 320 400 250 320 400 250 320 400 600 *) All UL listed products (except side operated) are also IEC rated up to 800 A **) UL98B self-certified at 1500 VDC while standard only goes up to 1000 VDC Switches for PV applications Product overview 5

DC disconnect switches, front operated 16...600 A, UL * ) UL98B Ile #E354681 TDC250US02 TDC250US11 TDC250US22 TDC600USPP22 TDC320US02 TDC320US11 TDC320US22 TDC400US02 TDC400US11 TDC400US22 Rated Voltage [V DC] 1000 1000 1000 1000 Rated current [A] 250 320 400 250 320 400 250 320 400 600 *) All UL listed products (except side operated) are also IEC rated up to 800 A DC disconnect switches, side operated 100...400 A, UL UL-types UL98B Ile #E354681 TDC100U20S TDC250U20S TDC100US20S TDC250US20S TDC200U20S TDC320U20S TDC200US20S TDC320US20S TDC400U20S TDC400US20S Rated voltage [V DC] 1000 1000 1000 1000 Rated current [A] 100 200 250 320 400 100 200 250 320 400 6 Product overview Switches for PV applications

Switches for photovoltaic applications Up to 1500 VDC TDC16...32 - Simply efficient TDC from 16 32 Amperes have various DC voltage ratings within the same footprint area. Thanks to its modular design the rated operational voltage can be scaled according to your needs, up to 1000 V. Reliable PV systems at a wide voltage range TDC switch-disconnectors can be DIN rail or screw mounted. Tunnel terminals capture fine stranded wires and they are wide enough to allow wires up to 16 mm 2. Shortcircuit bars are pre-installed as standard. Simple and fast installation TDC16 32 is also available in a plastic enclosure, suitable for outdoor use. Enclosed TDCP is made of material resistant to UV light and water exposure. The enclosure has a high degree of protection, IP65. Cover interlock and padlockable handle ensure safe usage. TDC16 32 switches, with or without enclosure, meet the standard s thermal requirements, even in exceptionally high operating ambient temperatures. The power losses are very low, maximizing the efficiency. TDC100...800 - Switches for single and multi circuit disconnecting TDC has been designed for DC applications and tested beyond requirements. Reliable DC breaking power at all current levels As a result of symmetric pole design, the connections are independent of polarity. The user can make the connections in both ways. Simplicity in installation TDC is the only DC switch in the market that has visible contacts. The operation of the switch is not vulnerable to voltage peaks and it is independent of the user (quick makequick brake). Safe and reliable operation Thanks to a modular design and the use of ABB's connection kits, TDC adapts to different installation requirements: single or multicircuit, 1500 VDC, side operation or combined outputs up to 1500 A. Superior flexibility Suitable for warm locations Maximum energy efficiency of PV systems Switches for PV applications Product overview 7

Technical data TDC16...800 and TDCP16...32 Technical data according to IEC 60947 for switch-disconnectors TDC16...250 Switch size TDC16 TDC25 TDC32 TDC16U TDC25U TDC32U TDC100E TDC160E TDC200E TDC250E Rated insulation voltage U i Pollution degree 2 V 1250 1) 1250 1) 1250 1) 1250 1) 1250 1) 1250 1) Pollution degree 3 V 1000 1) 1000 1) 1000 1) 1000 1) 1000 1) 1000 1) 1000 1000 1000 1000 Dielectric strength 50 Hz 1 min kv 6 6 6 6 6 6 Rated impulse withstand voltage kv 8 8 8 8 8 8 12 12 12 12 Rated thermal current I th In open air, normal conditions 2) A 25 32 45 40 50 63 100 160 200 250 In enclosure 40 C A 25 32 45 32 40 50 100 160 200 250 In enclosure 60 C A 25 32 32 25 32 40 100 160 200 200...with minimum cable or bar cross section Cu mm² 4 6 10 4 6 10 35 70 95 120 Rated operational current / 500 ne circuit V 100 / 1 160 / 1 200 / 1 250 / 1 poles in series 660 ne circuit V 16/2 25/2 32/2 16/2 25/2 DC-21B Two circuits V 25/2 25/2 32/2 16/2 25/2 32/2 1000 ne circuit V 10/2 16/2 20/2 10/2 4) 16/2 4) 100 / 2 160 / 2 200 / 2 250 / 2 V 16/3 25/3 32/3 Two circuits V 10/2 16/2 20/2 10/2 4) 16/2 4) 20/2 4) 100 / 2 160 / 2 200 / 2 250 / 2 Three circuits V 10/2 4) Rated short-time withstand current, 1000 V, 1 s R.M.S. -value I cw ka 0,4 0,6 0,8 1,0 1,0 1,0 5 5 5 5 Rated short circuit making Peak value I cm ka 5 5 5 5 capacity, 1000 V Max. distance from switch frame to nearest busbar / cable support mm 150 150 150 150 Rated conditional short-circuit I p (r.m.s.), 1000 V ka 10 10 10 current I p (r.m.s.) Max fuse size, gpv A 80 80 80 Power loss / pole At rated current W 0,15 0,3 0,5 0,1 0,2 0,35 2 4 6 9,5 Terminal cable size Cu mm² 2.5...16 2.5...16 2.5...16 2.5...16 2.5...16 2.5...16 Terminal bolt size Metric thread diameter length mm M8x25 M8x25 M8x25 M8x25 Terminal tightening torque Counter torque required Nm 15-22 15-22 15-22 15-22 1) When used with external handle. or use with direct mounted handle, see installation instruction. 2) Normal conditions defined in IEC 60947-1-6.1 3) 1000 V with all the poles connected in series, 600 V with 2 poles in series 4) U and UT types only. (Not applicable for US nor UST.) 8 Technical data Switches for PV applications

Technical data according to IEC 60947 for switch-disconnectors TDC315...800 Switch size TDC315E TDC400E TDC500E TDC630E TDC800E Rated insulation voltage U i Pollution degree 2 V 1500 1500 1500 1500 1500 Pollution degree 3 V 1500 1500 1500 1500 1500 Rated impulse withstand voltage kv 12 12 12 12 12 Rated thermal current I th In open air, normal conditions 5) A 315 400 630 630 800 In enclosure 40 C A 315 400 550 630 800 In enclosure 60 C A 315 400 440 630 680...with minimum cable or bar cross section Cu mm² 185 240 240 2x185 2x240 Rated operational current / poles in series 1000 ne circuit V 315/2 400/2 500/2 630/2 800/2 Two circuits V 315/2 400/2 500/2 Three circuits V 315/2 400/2 500/2 1500 ne circuit V 315/3 400/3 500/3 V 315/4 400/4 500/4 Two circuits V 315/3 400/3 500/3 Rated short-time withstand current, 1000 V, 1 s R.M.S. -value I cw ka 10 10 10 10 10 Rated short circuit making capacity, 1000 V Peak value I cm ka 10 10 10 10 10 Power loss / pole At rated current W 6 9,7 15,1 29,1 40 Terminal bolt size Metric thread diameter length mm M 10x30 M 10x30 M 12x40 M 12x40 M 12x40 Terminal tightening torque Counter torque required Nm 30-44 30-44 50-75 50-75 50-75 5) Normal conditions defined in IEC 60947-1-6.1 6) 1000 V with all the poles connected in series, 600 V with 2 poles in series Technical data according to IEC 60947 for enclosed switch-disconnectors TDCP Switch size A TDCP16 TDCP25 TDCP32 Rated insulation voltage Pollution degree 2 V 1250 1250 1250 Pollution degree 3 V 1000 1000 1000 Dielectric strength 50 Hz 1 min kv 6 6 6 Rated impulse withstand voltage kv 8 8 8 Rated impulse withstand voltage In enclosure 40 C A 25 32 45 DC-20 In enclosure 60 C A 25 32 32 Rated operational current / poles in series 660 V A 16/2 25/2 32/2 DC-21B 1000 V A 16/3 25/3 32/3 2x660 V 9) A 16/4 25/4 32/4 Rated short-time withstand current, 1000 V, 1 s R.M.S. -value I cw ka 0.4 0.6 0.8 Power loss / pole At rated current W 0.15 0.3 0.5 9) 1000 V with all the poles connected in series, 600 V with 2 poles in series Switches for PV applications Technical data 9

Technical data TDC16...600 Technical data in accordance to UL508I for photovoltaic disconnect switches TDC16...32U Suitable or Use in Photovoltaic Systems in Accordance With Article 690 of the NEC. Switch size TDC16U TDC25U TDC32U UL Listed Standard UL 508I UL 508I UL 508I Rated ambient temperature C +60 +60 +60 Rated current /poles in series 600 V ne circuit 16/2 25/2 Two circuits 16/2 25/2x2 32/2x2 Three circuits 16/2 Short circuit rating ka, 600 V 5 5 5 Protection type RK5 use RK5 use RK5 use Wire range MCM 12-6 AWG 12-6 AWG 12-6 AWG Technical data according to IEC 60947 See IEC table for type TDC16U TDC25U TDC32U Technical data in accordance to UL98B for photovoltaic disconnect switches TDC100...600U Suitable or Use in Photovoltaic Systems in Accordance With Article 690 of the NEC. Switch size TDC100U TDC200U TDC250U TDC320U TDC400U TDC600U UL Listed Standard UL 98B UL 98B UL 98B UL 98B UL 98B UL 98B Rated ambient temperature C -20...+50-20...+50-20...+50-20...+50-20...+50-20...+50 Rated current /poles in series 1000 V ne circuit 100/2 200/2 250/2 320/2 400/2 600/2 Two circuits 100/2 180/2 250/2 320/2 400/2 1500 V 7) ne circuit 250/3 320/3 400/3 Short circuit rating ka, 1000 V 5 5 10 10 10 10 Protection type Circuit breaker Circuit breaker Circuit breaker Circuit breaker Circuit breaker Circuit breaker Wire range MCM #4-300 #4-300 #2 600 #2 600 #2 600 #2 600 Technical data according to IEC 60947 See IEC table for type TDC160E TDC250E TDC315E TDC400E TDC500E TDC630E 7) or 4 pole switches (double circuit use), the current rating at 1000 VDC is 180 A. 8) 1500 V ratings are not within the scope of UL98B. 1500 V values are self-certified and tested at 1500 V, based on corresponding 1000 V UL98B guidelines. 10 Technical data Switches for PV applications

Type designation key TDC16...32, IEC TDC 16 3 1 2 3 4 1 Brand TDC ABB DC switch-disconnector brand 2 Switch size 16 32 16, 25 and 32 Amperes 3 Mounting/construction _ Base mounted, IEC U_ Base mounted, UL508i US_ Base mounted, UL, factory mounted jumpers UT Door mounted, UL UST Door mounted, UL, factory mounted jumpers T Door mounted, IEC 4 Number of poles 2 Two poles 3 Three poles 4 our poles 6 Six poles TDC100...800, IEC and UL98B TDC 200 U S 11 K 1 2 3 4 5 6 1 Brand TDC ABB DC switch-disconnector brand 2 Switch size 100 800 100 800 Amperes 3 Voltage and standard E 1000 VDC, IEC U 1000 VDC, UL98B 4 Short circuit links blank Short circuit links not included V actory mounted short circuit link, 1500 VDC S Pre-mounted short circuit links, single wire breaking PP Pre-mounted connection bars, supply and load side parallel 5 Number of poles 11 Two poles, mechanism between the poles 02, 20 Two poles, mechanism at the end of the switch 12 Three poles, mechanism between the poles 22 our poles, mechanism between the poles 04, 40 our poles, mechanism at the end of the switch 33 Six poles, mechanism between the poles 6 Included handle _ none P external handle K direct mount, front operation S direct mount, side operation TDCP16...32, IEC TDC P 16 S 11 M D 1 2 3 4 5 6 7 1 Brand TDC ABB DC switch-disconnector brand 2 Enclosure material P Plastic 3 Switch size 16 32 16, 25 and 32 Amperes 4 Selector handle color S Black SA Red-yellow 5 Contact configuration 11, 12, 22 See connection diagrams in pages 16-17 6 Cable entries M Threaded knock-out M20 M16 Threaded knock-out M16 U Blank cable entries UM Black top cable entry and threaded knockout M20 bottom cable entry M16 Threaded knockouts: M16 top cable entry and M20 bottom cable entry 7 Connection options _ Single circuit use D Double circuit use Switches for PV applications Technical data 11

TDC16 32 ordering information ront operated switch-disconnectors, IEC TDC16...322 Switch-disconnectors TDC_, base or DIN-rail mounting, IEC Types TDC16...32 include IP20 protected terminal clamps. Shafts and handles need to be ordered separetely, see pages 33-34. Short circuit links included in the package. TDC16...323 Single circuit use Up to 660 VDC Number Rated operat. current Weight/ of [A] unit poles DC 21B / 660 V Type rder number [kg] 2 16 TDC162 1SCA121454R1001 0.15 2 25 TDC252 1SCA121455R1001 0.15 2 32 TDC322 1SCA121456R1001 0.15 TDC16...324 - + TDC_2 1 3 - + 1-3 + 1 3 2 4 - + 2 4-2+ 4 - + TDC_3 - EZXY85 1 3 5 - EZXY85 1-3EZXY85 5 2 4 1 6 3 5 - + + 2 4 6-2+ 4+ 6 TDC_4- + + - EZXY85 1-3 5 7 EZXY85 + 1-3 EZXY85 5 7 + 2 4 1 6 3 8 5 - + EZXY86 2 4 6 8-2+ 4EZXY86 6 - + + 7 8 EZXY86 Up to 1000 VDC Number Rated operat. current Weight/ of [A] unit poles DC 21B / 1000 V Type rder number [kg] 2 10 TDC162 1SCA121454R1001 0.20 2 16 TDC252 1SCA121455R1001 0.20 2 20 TDC322 1SCA121456R1001 0.20 3 16 TDC163 1SCA121457R1001 0.20 3 25 TDC253 1SCA121458R1001 0.20 3 32 TDC323 1SCA121459R1001 0.20 Double circuit use Up to 1000 VDC Number Rated operat. current of [A] Weight/ poles DC 21B / DC 21B / unit 660 V 1000 V Type rder number [kg] 2x2 16 10 TDC164 1SCA121461R1001 0.25 2x2 25 16 TDC254 1SCA121462R1001 0.25 2x2 32 20 TDC324 1SCA121463R1001 0.25 12 rdering information Switches for PV applications

TDC16 32 ordering information ront operated switch-disconnectors, UL TDC16U2, TDC16US2 Switch-disconnectors TDC_, base or DIN-rail mounting, UL Touch-safe IP20 protected terminal clamps included. Types TDC16 32US include premounted short circuit link EZXY86. Shafts and handles to be ordered separately. TDC16U4, TDC16US4 TDC16U6, TDC16US6 TDC_US2 Panel 1 EZXY86 1 3 2 4 + + (-) (-) Inverter 1 TDC_US6 EZXY86 1 3 Panel 2 Panel 1 TDC_US4 EZXY86 1 3 2 4 + + (-) (-) Inverter 2 + + (-) (-) Inverter 1 Panel 2 EZXY86 Inverter 2 + + (-) (-) 5 7 6 8 EZXY86 5 7 9 11 Single circuit Number Rated operat. current [A] Weight/ of UL IEC unit poles 600 VDC 660 VDC 1000 VDC Type rder number [kg] 2 16 16 10 TDC16U2 1SCA134369R1001 0.15 2 25 25 16 TDC25U2 1SCA134375R1001 0.15 2 16 16 - TDC16US2 1SCA134372R1001 0.15 2 25 25 - TDC25US2 1SCA134378R1001 0.15 Double circuit Number Rated operat. current [A] Weight/ of UL IEC unit poles 600 VDC 660 VDC 1000 VDC Type rder number [kg] 4 16 16 10 TDC16U4 1SCA134370R1001 0.15 4 25 25 16 TDC25U4 1SCA134377R1001 0.15 4 32 32 20 TDC32U4 1SCA136703R1001 0.15 4 16 16 - TDC16US4 1SCA134373R1001 0.15 4 25 25 - TDC25US4 1SCA134379R1001 0.15 4 32 32 - TDC32US4 1SCA136704R1001 0.15 Triple circuit Number Rated operat. current [A] Weight/ of UL IEC unit poles 600 VDC 660 VDC 1000 VDC Type rder number [kg] 6 16 16 10 TDC16U6 1SCA134371R1001 0.15 6 16 16 - TDC16US6 1SCA134374R1001 0.15 Panel 1 2 4 + + (-) (-) Inverter 1 TDC_U2 6 8 EZXY86 Panel 3 TDC_U4 10 12 + + (-) (-) Inverter 3 Inverter 1 + (-) Inverter 1 - (+) 1 3 Inverter 1 + (-) Inverter 1 - (+) 1 3 Inverter 2 + (-) Inverter 2 - (+) 5 7 Panel 1 2 4 + - (-) (+) Panel 1 TDC_U6 Panel 1 2 4 + - (-) (+) Panel 1 Panel 2 6 8 + - (-) (+) Panel 2 Inverter 1 + (-) Inverter 1 - (+) 1 3 Inverter 2 + (-) Inverter 2 - (+) 5 7 Inverter 3 + (-) Inverter 3 - (+) 9 11 Panel 1 2 4 + - (-) (+) Panel 1 Panel 2 6 8 + - (-) (+) Panel 2 Panel 3 10 12 + - (-) (+) Panel 3 Switches for PV applications rdering information 13

TDC16 32 ordering information ront operated switch-disconnectors, IEC TDC16...32T2 Switch-disconnectors TDC_, door mounting, IEC Types TDC16...32 include IP20 protected terminal clamps. Shafts and handles need to be ordered separetely, see pages 33-34. Short circuit links included in the package. TDC16...32T3 TDC16...32T4 - + TDC_T2 1-3 + 1-3 + 2 4 - + 2 4-2+ 4 - + TDC_T3 - EZXY85 1 3 1-3 EZXY85 5 1-3EZXY85 5 1 3 5 2 4 6 - + 2 + 4 6-2+ 4+ 6 - + + TDC_T4 Single circuit use Up to 660 VDC Number Rated operat. current Weight/ of [A] unit poles DC 21B / 660 V Type rder number [kg] 2 16 TDC16T2 1SCA123839R1001 0.15 2 25 TDC25T2 1SCA123842R1001 0.15 2 32 TDC32T2 1SCA123845R1001 0.15 Up to 1000 VDC Number Rated operat. current Weight/ of [A] unit poles DC 21B / 1000 V Type rder number [kg] 2 10 TDC16T2 1SCA123839R1001 0.20 2 16 TDC25T2 1SCA123842R1001 0.20 2 20 TDC25T2 1SCA123845R1001 0.20 3 16 TDC16T3 1SCA123840R1001 0.20 3 25 TDC25T3 1SCA123843R1001 0.20 3 32 TDC32T3 1SCA123846R1001 0.20 Double circuit use Up to 1000 VDC Number Rated operat. current of [A] Weight/ poles DC 21B / DC 21B / unit 660 V 1000 V Type rder number [kg] 2x2 16 10 TDC16T4 1SCA123841R1001 0.25 2x2 25 16 TDC25T4 1SCA123844R1001 0.25 2x2 32 20 TDC32T4 1SCA123847R1001 0.25 - EZXY85 + 1-3 EZXY85 5 7 + 1-3 EZXY85 5 7 + 1 3 5 7 2 4 6 8 - + 2 EZXY86 4 6 8-2+ 4EZXY86 6 8 - + EZXY86 14 rdering information Switches for PV applications

TDC16 32 ordering information ront operated switch-disconnectors, UL TDC16UT2, TDC16UST2 Switch-disconnectors TDC16 32U_T, door mounting Touch-safe IP20 protected terminal clamps included. Types TDC16 32US include premounted short circuit link EZXY86. Shafts and handles to be ordered separately. TDC16UT4, TDC16UST4 Single circuit - up to 1000 VDC Number Rated operat. current [A] Weight/ of UL IEC unit poles 600 VDC 660 VDC 1000 VDC Type rder number [kg] 2 16 16 10 TDC16UT2 1SCA134387R1001 0.15 2 25 25 16 TDC25UT2 1SCA134388R1001 0.15 2 16 16 - TDC16UST2 1SCA134581R1001 0.15 2 25 25 - TDC25UST2 1SCA134578R1001 0.15 TDC16UT6, TDC16UST6 TDC_UST2 Panel 1 EZXY86 1 3 2 4 + + (-) (-) Inverter 1 TDC_UST6 EZXY86 1 3 Panel 2 Panel 1 TDC_UST4 EZXY86 1 3 2 4 + + (-) (-) Inverter 2 + + (-) (-) Inverter 1 Panel 2 EZXY86 Inverter 2 + + (-) (-) 5 7 6 8 EZXY86 5 7 9 11 Double circuit - up to 1000 VDC Number Rated operat. current [A] Weight/ of UL IEC unit poles 600 VDC 660 VDC 1000 VDC Type rder number [kg] 4 16 16 10 TDC16UT4 1SCA134390R1001 0.15 4 25 25 16 TDC25UT4 1SCA134391R1001 0.15 4 32 32 20 TDC32UT4 1SCA136705R1001 0.15 4 16 16 - TDC16UST4 1SCA134582R1001 0.15 4 25 25 - TDC25UST4 1SCA134579R1001 0.15 4 32 32 - TDC32UST4 1SCA136706R1001 0.15 Triple circuit - up to 1000 VDC Number Rated operat. current [A] Weight/ of UL IEC unit poles 600 VDC 660 VDC 1000 VDC Type rder number [kg] 6 16 16 10 TDC16UT6 1SCA134580R1001 0.15 6 16 16 - TDC16UST6 1SCA134583R1001 0.15 Panel 1 2 4 + + (-) (-) Inverter 1 TDC_UT2 6 8 EZXY86 Panel 3 TDC_UT4 10 12 + + (-) (-) Inverter 3 Inverter 1 + (-) Inverter 1 - (+) 1 3 Inverter 1 + (-) Inverter 1 - (+) 1 3 Inverter 2 + (-) Inverter 2 - (+) 5 7 Panel 1 2 4 + - (-) (+) Panel 1 TDC_UT6 Panel 1 2 4 + - (-) (+) Panel 1 Panel 2 6 8 + - (-) (+) Panel 2 Inverter 1 + (-) Inverter 1 - (+) 1 3 Inverter 2 + (-) Inverter 2 - (+) 5 7 Inverter 3 + (-) Inverter 3 - (+) 9 11 Panel 1 2 4 + - (-) (+) Panel 1 Panel 2 6 8 + - (-) (+) Panel 2 Panel 3 10 12 + - (-) (+) Panel 3 Switches for PV applications rdering information 15

TDCP16 32 ordering information Enclosed switch-disconnectors, IEC TDCP_SA_ Plastic enclosed switch-disconnectors TDCP_, IEC M20 threaded knock-outs, compression glands have to be ordered separately. M16 threaded knock-outs available on request. TDCP_S_ Up to 660 VDC Number Rated operat. current [A] Weight/ of DC 21B / unit poles 660 V Type rder number [kg] Includes red-yellow selector handle (I-0 and - indication) 2 16 TDCP16SA11M 1SCA125126R1001 0.55 2 25 TDCP25SA11M 1SCA125127R1001 0.55 2 32 TDCP32SA11M 1SCA125128R1001 0.55 Includes black selector handle (I-0 and - indication) 2 16 TDCP16S11M 1SCA125129R1001 0.55 2 25 TDCP25S11M 1SCA125130R1001 0.55 2 32 TDCP32S11M 1SCA125131R1001 0.55 TDCP_11_ TDCP_11_ TDCP_11_ - + - + -1 + 3 1 3 1 3 2 4 2 2 4 4 Load Load Load TDCP_12_ TDCP_12_ TDCP_12_ - - - 1 3 5 1 1 3 3 5 5 2 4 6 2 2 4 4 6 + 6 Load + + Load Load TDCP_22_ TDCP_22_ TDCP_22_ - - 1 3 5 7 1 3 5 7 Up to 1000 VDC Number Rated operat. current [A] Weight/ of DC 21B / unit poles 1000 V Type rder number [kg] Includes red-yellow selector handle (I-0 and - indication) 3 16 TDCP16SA12M 1SCA125150R1001 0.55 3 25 TDCP25SA12M 1SCA125151R1001 0.55 3 32 TDCP32SA12M 1SCA125152R1001 0.55 Includes black selector handle (I-0 and - indication) 3 16 TDCP16S12M 1SCA125153R1001 0.59 3 25 TDCP25S12M 1SCA125154R1001 0.59 3 32 TDCP32S12M 1SCA125155R1001 0.59 Up to 1000 VDC or 2x660 VDC 1) Number Rated operat. current [A] Weight/ of DC 21B / unit poles 1000 V Type rder number [kg] Includes red-yellow selector handle (I-0 and - indication) 4 16 TDCP16SA22M 1SCA125094R1001 0.63 4 25 TDCP25SA22M 1SCA125091R1001 0.63 4 32 TDCP32SA22M 1SCA125090R1001 0.63 Includes black selector handle (I-0 and - indication) 4 16 TDCP16S22M 1SCA125095R1001 0.63 4 25 TDCP25S22M 1SCA125092R1001 0.63 4 32 TDCP32S22M 1SCA125093R1001 0.63 2 4 6 8 2 + 4 6 8 + Load Load 16 rdering information Switches for PV applications

TDCP16 32 ordering information Enclosed switch-disconnectors, IEC TDCCP22_22_MD - + - + 1 3 5 7 2 4 6 8 - + - + Double circuit Number Rated operat. current [A] Weight/ of DC 21B / DC 21B / unit poles 660 V 1000 V Type rder number [kg] Includes red-yellow selector handle (I-0 and - indication) 4 16 10 TDCP16SA22MD 1SCA131850R1001 0.63 4 25 16 TDCP25SA22MD 1SCA131851R1001 0.63 4 32 20 TDCP32SA22MD 1SCA131852R1001 0.63 Includes black selector handle (I-0 and - indication) 4 16 10 TDCP16S22MD 1SCA131730R1001 0.63 4 25 16 TDCP25S22MD 1SCA131731R1001 0.63 4 32 20 TDCP32S22MD 1SCA131732R1001 0.63 Switches for PV applications rdering information 17

TDC100 800 ordering information ront operated switch-disconnectors, IEC TDC100...250E02 Single circuit, 1000 VDC, IEC - 100 to 800 A TDC100...250E11 Shafts and handles are not included. Switches with external handle (TDC_P, e.g. TDC200E02P) or direct mount handle (TDC_K, e.g.tdc400e02k) are available. Phase barriers included if mandatory. Included terminal bolts: - TDC100...250: M8x25 - TD315...400: M10x30 - TDC500...800: M12x40 TDC315...500E02 TDC315...500E11 TDC630..800EPP22 Number Rated operat. Weight/ Recommended of current [A] unit handle poles DC 21B / 1000 V Type rder number [kg] Direct mount (K) External (P) + shaft ront operated, mechanism at the end of the switch. 2 100 TDC100E02 1SCA125822R1001 1.1 TDV250EK HB65J6 2 160 TDC160E02 1SCA125840R1001 1.1 + shaft XP6x210 2 200 TDC200E02 1SCA123687R1001 1.1 2 250 TDC250E02 1SCA125866R1001 1.1 2 315 TDC315E02 1SCA132337R1001 4.3 TDV400EK HB95J12 2 400 TDC400E02 1SCA132349R1001 4.3 + shaft XP12x185 2 500 TDC500E02 1SCA132357R1001 4.3 ront operated, mechanism between the poles. TDC_EPP types inlcude pre-mounted connection bars. 2 100 TDC100E11 1SCA125821R1001 1.1 TDV250EK HB65J6 2 160 TDC160E11 1SCA123745R1001 1.1 + shaft XP6X210 2 200 TDC200E11 1SCA125626R1001 1.1 2 250 TDC250E11 1SCA125865R1001 1.1 2 315 TDC315E11 1SCA130982R1001 4.3 TDV400EK HB95J12 2 400 TDC400E11 1SCA130983R1001 4.3 + shaft XP12x185 2 500 TDC500E11 1SCA132135R1001 4.3 2 630 TDC630EPP22 1SCA137205R1001 7 TDV400EK HB95J12 + shaft XP12x185 2 800 TDC800EPP22 1SCA137210R1001 7 Connection kits and shrouds See pages 20-21 for circuit diagrams, connection kits and link shrouds. The column " quantity" tells how many pieces need to be ordered for each switch. The kits include the needed short circuit links, screws and washers. Connection kit/ short circuit link Recommended shroud Switches Circuit type Type Quantity Type quantity TDC100 500E02, 2a, 2b - - - - TDC100 500E11 TDC630...800EPP22 *) 6c - - TDCS400T2L 4 *) Connection bars are premounted for all TDC_EPP types 18 rdering information Switches for PV applications

TDC100 800 ordering information ront operated disconnect switches, UL TDC100...200US02 Single circuit, 1000 VDC, UL98B - 100 to 600 A TDC250...400US11 TDC250...400U11 TDC600USPP22 TDC600UPP22 Shafts and handles are not included. Switches with direct mount handle (TDC_K, e.g. TDC400E02K) are available. Phase barriers are included if mandatory. Included terminal bolts: - TDC100...200: M8x25 - TD250...320: M10x30 - TDC400...600: M12x40 Number of Rated operat. current [A] Weight/ unit Recommended handle poles UL98B / 1000 V Type rder number [kg] Direct mount (K) ront operated, mechanism at the end of the switch. TDC_US types inlcude pre-mounted short circuit link. 2 100 TDC100US02 1SCA126155R1001 1.2 TDV250EK 2 200 TDC200US02 1SCA126121R1001 1.2 2 100 TDC100U02 1SCA126184R1001 1.1 2 200 TDC200U02 1SCA126123R1001 1.1 2 250 TDC250US02 1SCA132335R1001 4.4 TDV400EK 2 320 TDC320US02 1SCA132345R1001 4.4 2 400 TDC400US02 1SCA132354R1001 4.4 2 250 TDC250U02 1SCA132330R1001 3.8 TDV400EK 2 320 TDC320U02 1SCA132341R1001 3.8 2 400 TDC400U02 1SCA132352R1001 3.8 ront operated, mechanism between the poles. TDC_US and TDC_U_PP types inlcude pre-mounted short circuit links/bars. 2 100 TDC100US11 1SCA125437R1001 1.2 TDV250EK 2 200 TDC200US11 1SCA125436R1001 1.2 2 100 TDC100U11 1SCA123957R1001 1.1 2 200 TDC200U11 1SCA123767R1001 1.1 2 250 TDC250US11 1SCA131012R1001 4.4 TDV400EK 2 320 TDC320US11 1SCA131013R1001 4.4 2 400 TDC400US11 1SCA131014R1001 4.4 2 250 TDC250U11 1SCA130985R1001 3.8 2 320 TDC320U11 1SCA130986R1001 3.8 2 400 TDC400U11 1SCA130990R1001 3.8 2 600 TDC600USPP22 1SCA137213R1001 7.9 TDV400EK 2 600 TDC600UPP22 1SCA137207R1001 7 Switches for PV applications rdering information 19

TDCKIT400S101 Connection kits and shrouds Pre-mounted short circuit links/connection bars are included for all TDC_US and TDC_UPP types. Shrouds must be ordered separately. See pages 20-21 for circuit diagrams, connection kits and shrouds. The column " quantity" tells how many pieces need to be ordered for each switch. The kits include the needed short circuit links/bars, screws and washers. Connection kit/ short circuit link Recommended shroud Switches Circuit type Type quantity Type quantity TDC100 200US11, TDC100 200US02 1a, 1b - - EZXY92 1 TDC100 200U11, TDC100 200U02 2a, 2b - - - - TDC250 400US11, TDC250 400US02 1a, 1b - - EZXY97 1 TDC250 400U11, TDC250 400U02 1a, 1b TDCKIT400S101 1 EZXY97 1 TDC250 400U11, TDC250 400U02 2a, 2b - - - - TDC600UPP22 6c - - TDCS400T2L 4 TDC600USPP22 6e - - TDCS400T2L 2 6e - - TDCS2504GB 1 Circuit 1a, 1b, 1000 VDC TDCKIT400S101 / EZX91 +(-) +(-) +(-) +(-) TDCB_/_ *) EZXY_ Circuit 1a, 1b Accessories for TDC315...500E,TDC250...400U Description Type rder number quantity short circuit link -KIT TDCKIT400S101 1SCA136280R1001 1 Recommended shroud EZXY97 1SCA130816R1001 1 Circuit 1a Accessories for TDC100...250E Description Type rder number quantity short circuit link -KIT EZXY91 1SCA125290R1001 1 Recommended shroud EZXY92 1SCA127382R1001 1 Circuit 2a, 2b, 1000 VDC +(-) -(+) +(-) -(+) +(-) -(+) +(-) -(+) TDCB_/_ *) *) TDCB_/_ phase barrier(s) included if mandatory 20 rdering information Switches for PV applications

Circuit 6c, 6g, 1000 VDC +(-) -(+) TDCS400T2L +(-) -(+) Circuit 6c, 6g Accessories for TDC630...800EPP, TDC600UPP Description Type rder number quantity short circuit link -KIT - - - Recommended shroud TDCS400T2L 1SCA136275R1001 4 Circuit 6e, 1000 VDC TDCS400G4B +(-) +(-) TDCS400T2L Circuit 6e Accessories for TDC600USPP Description Type rder number quantity Type rder number quantity short circuit link -KIT - - - - - - Recommended shroud TDCS400T2L 1SCA136275R1001 2 TDCS250G4B 1SCA136274R1001 1 Switches for PV applications rdering information 21

TDC100 800 ordering information ront operated switch-disconnectors, IEC TDC100...250E22 Double circuit and load side combining, 1000 VDC, IEC - 100...500 A TDC315...500E22 The switches TDC_E22 can be used for double circuit applications or to create a combined output up to 1000 A. Shafts and handles are not included. Switches with external handle (TDC_P, e.g. TDC200E22P) or direct mount handle (TDC_K, e.g. TDC400E22K) are available. Phase barriers included if mandatory. Included terminal bolts: - TDC100...250: M8x25 - TD315...400: M10x30 - TDC500: M12x40 Number Rated operat. Weight/ Recommended of current [A] unit handle poles DC 21B / 1000 V Type rder number [kg] Direct mount (K) External (P) + shaft Mechanism between the poles 2x2 100 TDC100E22 1SCA125824R1001 1.9 TDV250EK HB65J6 2x2 160 TDC160E22 1SCA125844R1001 1.9 + shaft XP6x210 2x2 200 TDC200E22 1SCA125856R1001 1.9 2x2 250 TDC250E22 1SCA125869R1001 1.9 2x2 315 TDC315E22 1SCA131001R1001 6.6 TDV400EK HB95J12 2x2 400 TDC400E22 1SCA131036R1001 6.6 + shaft XP12x185 2x2 500 TDC500E22 1SCA132142R1001 7 TDCKIT400B11 Connection kits and shrouds See pages 24-25 for circuit diagrams, connection kits and shrouds. The column " quantity" tells how many pieces need to be ordered for each switch. The kits include the needed short circuit links/bars, screws and washers. Connection kit/ short circuit link Recommended shroud Switches Circuit type Type Quantity Type Quantity TDC100 500E22 4a, 4c - - - - TDC315...500E22 6d TDCKIT400B11 2 TDCS400T2L 2 22 rdering information Switches for PV applications

TDC100 800 ordering information ront operated disconnect switches, UL TDC100...180US22 Double circuit and load side combining, 1000 VDC, UL98B -100...400 A TDC100...200U22 The switches TDC_U22 and TDCUS22 can be used for double circuit applications or to create a combined output up to 800 A. Shafts and handles are not included. Switches with direct mount handle (TDC_K, e.g. TDC400U22K) are available. Phase barriers are included if mandatory. Included terminal bolts: - TDC100...200: M8x25 - TD250...320: M10x30 - TDC400: M12x40 TDC250...400US22 TDC250...400U22 Number of Rated operat. current [A] Delivery batch Weight/ unit Recommended handle poles UL98B / 1000 V Type rder number [pcs] [kg] Direct mount (K) Mechanism between the poles. TDC_US types inlcude pre-mounted short circuit links. 2X2 100 TDC100US22 1SCA126181R1001 1 2.5 TDV250EK 2X2 180 TDC180US22 1SCA126942R1001 1 2.5 2X2 100 TDC100U22 1SCA126180R1001 1 2.3 TDV250EK 2X2 180 TDC180U22 1SCA126941R1001 1 2.3 2X2 250 TDC250US22 1SCA131030R1001 1 6.6 TDV400EK 2X2 320 TDC320US22 1SCA131032R1001 1 6.6 2X2 400 TDC400US22 1SCA132300R1001 1 6.6 2X2 250 TDC250U22 1SCA131003R1001 1 6.6 TDV400EK 2X2 320 TDC320U22 1SCA131006R1001 1 6.6 2X2 400 TDC400U22 1SCA131010R1001 1 6.6 Connection kits and shrouds TDCKIT400S11 Pre-mounted short circuit links/connection bars are included for all TDC_US types. Shrouds must be ordered separately. See pages 24-25 for circuit diagrams, connection kits and shrouds. The column " quantity" tells how many pieces need to be ordered for each switch. The kits include the needed short circuit links/bars, screws and washers. TDCKIT400B11 Connection kit/ short circuit link Recommended shroud Switches Circuit type Type quantity Type quantity TDC100 180US22 *) 3 EZXY91 2 EZXY92 2 TDC250 400US22 *), 3 TDCKIT400S11 2 TDCS400G2B 2 TDC250 400U22 TDC100...180U22, 4a - - - - TDC250...400U22 TDC250...400U22 6d TDCKIT400B11 2 TDCS400T2L 2 TDC250...400US22 *) 6f TDCKIT400B101 1 TDCS400G2B 2 TDC400T11L 1 *) Short circuit links are premounted, for circuit 6f TDCKIT400B101 must be ordered separately Switches for PV applications rdering information 23

Circuit 3, 1000 VDC - Double circuit TDCKIT400S11 +(-) +(-) +(-) +(-) 1 1 2 2 TDCB_/_ *) TDCS400G2B Circuit 3 Accessories for TDC315...500E, TDC250...400U Description Type rder number quantity short circuit link -KIT TDCKIT400S11 1SCA136281R1001 2 Recommended shroud TDCS400G2B 1SCA136273R1001 2 Circuit 3 Accessories for TDC100...250E Description Type rder number quantity short circuit link -KIT EZXY91 1SCA125290R1001 2 Recommended shroud EZXY92 1SCA127382R1001 2 Circuit 4a, 4c, 1000 VDC - Double circuit +(-) -(+) +(-) -(+) +(-) -(+) +(-) -(+) 1 1 2 2 TDCB_/_ *) Circuit 6d, 1000 VDC - Load side combining 1+2 LAD 1+2 +(-) -(+) TDCS400T2L TDCKIT400B11 +(-) +(-) 1 2 -(+) -(+) 1 2 TDCB_/_ *) Circuit 6d Accessories for TDC315...500E, TDC250...400U Description Type rder number quantity connection bar kit TDCKIT400B11 1SCA136282R1001 2 Recommended shroud TDCS400T2L 1SCA136275R1001 2 *) TDCB_/_ phase barrier(s) included if mandatory 24 rdering information Switches for PV applications

Circuit 6f, 1000 VDC - Load side combining TDCS400G2B +(-) +(-) +(-) 1 1+2 LAD 2 TDCB_/_ *) TDCKIT400B101 TDC400T11L Circuit 6f Accessories for TDC250...400US Description Type rder number quantity Type rder number quantity connection bar kit TDCKIT400B101 1SCA136283R1001 1 - - - Recommended shroud TDCS400G2B 1SCA136273R1001 2 TDCS400T11L 1SCA136279R1001 1 *) TDCB_/_ phase barrier(s) included if mandatory Switches for PV applications rdering information 25

TDC100 800 ordering information ront operated switch-disconnectors, IEC TDC315...500E33 Triple circuit and load side combining, up to 1000 VDC, IEC - 315...500 A The switches TDC_E33 can be used for triple circuit applications or to create a combined output up to 1500 A. Shafts and handles are not included. Switches with external handle (TDC_P, e.g. TDC400E33P) or direct mount handle (TDC_K, e.g. TDC400E33K) are available. Terminal bolts M12x40 included. Phase barriers included if mandatory. Number Rated operat. Weight/ Recommended of current [A] unit handle poles DC 21B / 1000 V Type rder number [kg] Direct mount (K) External (P) + shaft Mechanism between the poles, single circuit 2x3 315 TDC315E33 1SCA137230R1001 6.6 TDV400EK2 HB145J12 2x3 400 TDC400E33 1SCA137231R1001 6.6 + shaft XP12x185 2x3 500 TDC500E33 1SCA137234R1001 6.6 TDCKIT400B111 Connection kits and shrouds See page 27 for circuit diagrams, connection kits and shrouds. The column " quantity" tells how many pieces need to be ordered for each switch. The kits include the needed bars, screws and washers. Connection kit/ short circuit link Recommended shroud Switches Circuit type Type Quantity Type Quantity TDC315 500E33 7a, 7e - - - - 7d TDCKIT400B111 2 TDCS400T3L 2 26 rdering information Switches for PV applications

Circuit 7a,7e, 1000 VDC +(-) -(+) +(-) -(+) +(-) -(+) +(-) -(+) +(-) -(+) +(-) -(+) 1 1 2 2 3 3 TDCB_/_ *) Circuit 7d, 1000 VDC 1+2+3 LAD 1+2+3 +(-) -(+) TDCS400T3L TDCKIT400B111 +(-) +(-) +(-) -(+) -(+) -(+) 1 2 3 1 2 3 TDCB_/_ *) Circuit 7d Accessories for TDC315...500E Description Type rder number quantity short circuit link -KIT TDCKIT400B111 1SCA136284R1001 2 Recommended shroud TDCS400T3L 1SCA136276R1001 2 *) TDCB_/_ phase barrier(s) included if mandatory Switches for PV applications rdering information 27

TDC100 800 ordering information ront operated switch-disconnectors, IEC TDC315...500EV12 Single and double circuit, 1500 VDC, IEC - 315...500 A Shafts and handles are not included. Switches with external handle (TDC_P, e.g. TDC200EV12P) or direct mount handle (TDC_K, e.g. TDC400EV12K) are available. Phase barriers included if mandatory. Included terminal bolts: - TD315...400: M10x30 - TDC500: M12x40 TDC315...500E33 Number Rated operat. Weight/ Recommended of current [A] unit handle poles DC 21B / 1500 V Type rder number [kg] Direct mount (K) External (P)+ shaft Mechanism between the poles, single circuit. Pre-mounted short circuit link. 3 315 TDC315EV12 1SCA132258R1001 5.1 TDV400EK HB95J12 3 400 TDC400EV12 1SCA132256R1001 5.1 + shaft XP12x185 3 500 TDC500EV12 1SCA132257R1001 5.1 Mechanism between the poles, double circuit. 2x3 315 TDC315E33 1SCA137230R1001 6.6 TDV400EK2 HB145J12 2x3 400 TDC400E33 1SCA137231R1001 6.6 + shaft XP12x185 2x3 500 TDC500E33 1SCA137234R1001 6.6 TDCKIT400S101 Connection kits and shrouds TDCKIT400S11 Pre-mounted short circuit links/connection bars are included for TDC_EV types. Shrouds must be ordered separately. See pages 30-31 for circuit diagrams, connection kits and shrouds. The column " quantity" tells how many pieces need to be ordered for each switch. The kits include the needed short circuit links/bars, screws and washers. Connection kit/ short circuit link Recommended shroud Switches Circuit type Type quantity Type quantity TDC315 400EV12, 5a, 5b TDCKIT400S101 1 EZXY97 1 TDC315 400E12 TDC315 400E33 7b, 7g TDCKIT400S11 2 TDCS400G2B 2 28 rdering information Switches for PV applications

TDC100 800 ordering information ront operated disconnect switches, UL TDC250...400U12 Single circuit, 1500 VDC, UL 98B *) - 250...400 A Shafts and handles are not included. Switches with direct mount handle (TDC_K, e.g. TDC250U12K) are available. Phase barriers included if mandatory. Included terminal bolts: - TD315...400: M10x30 - TDC500: M12x40 Number of Rated operat. current [A] Weight/ unit Recommended handle poles UL98B / 1000 V Type rder number [kg] Direct mount (K) Mechanism between the poles 3 250 TDC250U12 1SCA135619R1001 4.7 TDV400EK 3 320 TDC320U12 1SCA135791R1001 4.7 3 400 TDC400U12 1SCA135792R1001 4.7 TDCKIT400S101 Connection kits and shrouds See pages 30-31 for circuit diagrams, connection kits and shrouds. The column " quantity" tells how many pieces need to be ordered for each switch. The kits include the needed short circuit links, screws and washers. Connection kit/ short circuit link Recommended shroud Switches Circuit type Type quantity Type quantity TDC250 400U12 5a, 5b, 5e TDCKIT400S101 1 EZXY97 1 TDC250...400U12 5c, 5d TDCKIT400S101 2 EZXY97 2 *) Tested as per UL98B 1000 VDC requirements, 1500 VDC standard has not been published yet Switches for PV applications rdering information 29

Circuit 5a, 5b, 5e, 1500 VDC -(+) TDCKIT400S101 -(+) +(-) +(-) EZXY97 TDCB_/_ *) Circuit 5a, 5b, 5e Accessories for TDC315...500E, TDC250...400U Description Type rder number quantity short circuit link -KIT TDCKIT400S101 1SCA136280R1001 1 Recommended shroud EZXY97 1SCA130816R1001 1 Circuit 5c, 5d, 1500 VDC +(-) TDCKIT400S101 +(-) TDCB_/_ *) EZXY_ Circuit 5c, 5d Accessories for TDC250...400U Description Type rder number quantity short circuit link -KIT TDCKIT400S101 1SCA136280R1001 2 Recommended shroud EZXY_ 1SCA130816R1001 2 *) TDCB_/_ phase barrier(s) included if mandatory 30 rdering information Switches for PV applications

Circuit 7b, 7g, 1500 VDC -(+) -(+) TDCKIT400S11 -(+) +(-) +(-) -(+) +(-) +(-) TDCS400G2B 1 2 TDCB400/2 *) Circuit 7b, 7g Accessories for TDC315...500E Description Type rder number quantity short circuit link -KIT TDCKIT400S11 1SCA136281R1001 2 Recommended shroud TDCS400G2B 1SCA136274R1001 2 *) TDCB_/_ phase barrier(s) included if mandatory Switches for PV applications rdering information 31

TDC100 800 ordering information Side operated disconnect switches, UL TDC100...200U20S Single circuit, 1000 VDC, UL98B - 100...400 A TDC100...200US20S TDC250...400U20S Shafts and handles are not included. TDC_US types inlcude pre-mounted short circuit link. The mechanism is located at the end of the switch. Included terminal bolts: - TDC100...200: M8x25 - TDC250..320: M10x30 - TDC400: M12x40 Number of Rated operat. current [A] Weight/ unit Recommended handle poles UL98B / 1000 V Type rder number [kg] Direct mount (K) External (P)+ shaft Single circuit 2 100 TDC100US20S 1SCA131541R1001 1.7 HB65JE005 2 200 TDC200US20S 1SCA131549R1001 1.7 + shaft XP6X210 2 100 TDC100U20S 1SCA131540R1001 1.3 HB65JE005 2 200 TDC200U20S 1SCA131548R1001 1.5 + shaft XP6X210 2 250 TDC250US20S 1SCA135730R1001 4.4 TDV400ESK HB145J12E00S + 2 320 TDC320US20S 1SCA135734R1001 4.4 shaft XP12x185 2 400 TDC400US20S 1SCA135726R1001 4.4 2 250 TDC250U20S 1SCA135729R1001 3.8 TDV400ESK HB145J12E00S + 2 320 TDC320U20S 1SCA135733R1001 3.8 shaft XP12x185 2 400 TDC400U20S 1SCA135725R1001 3.8 TDCKIT400S101 Connection kits and shrouds Pre-mounted short circuit links/connection bars are included for all TDC_US types. Shrouds must be ordered separately. See page 33 for circuit diagrams, connection kits and shrouds. The column " quantity" tells how many pieces need to be ordered for each switch. The kits include the needed short circuit links/bars, screws and washers. Connection kit/ short circuit link Recommended shroud Switches Circuit type Type quantity Type quantity TDC100 200US20S 1a - - EZXY92 1 TDC100 200U20S 2a, 2b - - - - TDC250 400US20S 1a - - EZXY97 1 TDC250 400U20S 1a TDCKIT400S101 1 EZXY97 1 TDC250 400U20S 2a, 2b - - - - 32 rdering information Switches for PV applications

Circuit 1a, 1000 VDC TDC100...200U_S EZXY91 TDC250 400U_S EZXY96 +(-) +(-) +(-) +(-) TDCB_/_ *) TDCB_/_ *) Circuit 2a, 2b, 1000 VDC TDC250 400U_S +(-) -(+) +(-) +(-) *) TDCB_/_ *) *) TDCB_/_ phase barrier(s) included if mandatory Switches for PV applications rdering information 33

TDC16 32 ordering information Accessories HBS11 Handle knobs for base and DIN rail mounted switches Mounting directly to the switch, no shaft needed, for base and DIN-rail mounted switches Padlockable with one padlock with bail diameter 5 mm, see the table below. HRS21 HRS31 Handle length Colour [mm] Type rder number Suitable for switches TDC16...32 Black 31 HBS1 1SCA109087R1001 Black 31 HBS1/1 1SCA109088R1001 Red 31 HRS1 1SCA109095R1001 Red 31 HRS1/1 1SCA109096R1001 Suitable for switches TDC16...32 Black 40 HBS2 1SCA109089R1001 Black 40 HBS2/1 1SCA109090R1001 Red 40 HRS2 1SCA108598R1001 Red 40 HRS2/1 1SCA108599R1001 Black 39 HBS3 1SCA108320R1001 Black 39 HBS3/1 1SCA108319R1001 Red 39 HRS3 1SCA108667R1001 Red 39 HRS3/1 1SCA108688R1001 Special information for handle knobs Shaft through 45 mm Handle type Padlockable the handle cut-out enable* HBS1_, HRS1_ No No Yes HBS2_, HRS2_ Yes No Yes HBS3_, HRS3_ No No Yes * In I-position the handle shall remain within the cut-out height 34 rdering information Switches for PV applications

TDC16 32 ordering information Accessories HBS3PH Selector handles, for door mounted switches Indication I- and -. No separate shaft needed. HBS2PJ HYS3RH HYS2RJ Colour Type rder number Snap-on mounting, door drilling 22,5 mm, for TDC16...32T No padlocking, IP54, NEMA 1 Black HBS1PH 1SCA105211R1001 Red-yellow HYS1PH 1SCA105294R1001 Silver HSS1PH 1SCA105276R1001 Grey HGS1PH 1SCA105263R1001 Padlockable with one padlock, IP54, NEMA 1 Black HBS3PH 1SCA105236R1001 Red-yellow HYS3PH 1SCA105327R1001 Silver HSS3PH 1SCA105285R1001 Grey HGS3PH 1SCA105272R1001 Padlockable with max. 3 padlocks, IP65, NEMA 1, 3R, 12 Black HBS2PJ 1SCA105231R1001 Red-yellow HYS2PJ 1SCA105322R1001 Silver HSS2PJ 1SCA105280R1001 Grey HGS2PJ 1SCA105268R1001 Screw mounting, hole distance 36 mm, for TDC16...32T No padlocking, IP54, NEMA 1 Black HBS1RH 1SCA105212R1001 Red-yellow HYS1RH 1SCA105295R1001 Silver HSS1RH 1SCA105277R1001 Grey HGS1RH 1SCA105264R1001 Padlockable with one padlock, IP54, NEMA 1 Black HBS3RH 1SCA105237R1001 Red-yellow HYS3RH 1SCA105328R1001 Silver HSS3RH 1SCA105286R1001 Grey HGS3RH 1SCA105273R1001 Padlockable with max. 3 padlocks, IP65, hole distance 36/48 mm, NEMA 1, 3R, 12 Black HBS2RJ 1SCA105232R1001 Red-yellow HYS2RJ 1SCA105323R1001 Silver HSS2RJ 1SCA105281R1001 Grey HGS2RJ 1SCA105269R1001 Switches for PV applications rdering information 35

TDC16 32 ordering information Accessories HBS3 Selector handles for base and DIN-rail mounted switches Indication I- and -, for shaft diameter 6 mm, door drilling 22.5 mm. HYS3 HBS2 Colour Type rder number IP 54 handles, NEMA 1, suitable for switches TDC16...32 Black HBS1AH 1SCA102680R1001 Yellow-red HYS1AH 1SCA105290R1001 Silver HSS1AH 1SCA105274R1001 Grey HGS1AH 1SCA105261R1001 Door interlock in -position. Black HBS1AH1 1SCA105210R1001 Yellow-red HYS1AH1 1SCA105291R1001 Silver HSS1AH1 1SCA105275R1001 Grey HGS1AH1 1SCA105262R1001 Padlockable with one padlock with bail diameter 5...6.3 mm. Black HBS3AH 1SCA105234R1001 Yellow-red HYS3AH 1SCA105325R1001 Silver HSS3AH 1SCA105283R1001 Grey HGS3AH 1SCA105270R1001 Padlockable with one padlock with bail diameter 5...6.3 mm, door interlock in -position. Black HBS3AH1 1SCA105235R1001 Yellow-red HYS3AH1 1SCA105326R1001 Silver HSS3AH1 1SCA105284R1001 Grey HGS3AH1 1SCA105271R1001 IP 65 handles, NEMA 1, 3R, 12, suitable for switches TDC16...32 Padlockable with max. 3 padlocks with bail diameter 5...8 mm, door interlock in -position, defeatable. Black HBS2AJ 1SCA105213R1001 Yellow-red HYS2AJ 1SCA105296R1001 Silver HSS2AJ 1SCA105278R1001 Grey HGS2AJ 1SCA105265R1001 Padlockable with max. 3 padlocks with bail diameter 5...8 mm, door interlock in -position. Black HBS2AJ1 1SCA105215R1001 Yellow-red HYS2AJ1 1SCA105297R1001 Silver HSS2AJ1 1SCA105279R1001 Grey HGS2AJ1 1SCA105266R1001 Selector type handle with metal hasp IP65 handles, NEMA 1, 3R, 12, suitable for switches TDC16...32 Padlockable with max. 3 padlocks, door interlock in the -position, defeatable. Black HBS2AJEH 1SCA108230R1001 36 rdering information Switches for PV applications

TDC16 32 ordering information Accessories XS6X_ Extended shafts for selector handles Shaft Weight/ length H unit [mm] [mm] Type rder number [kg] Suitable for switches TDC16...32, shaft diameter 6 mm 85 See XS6X85 1SCA101647R1001 0.02 105 dimension XS6X105 1SCA108043R1001 0.02 120 drawings XS6X120 1SCA101654R1001 0.03 130 XS6X130 1SCA101655R1001 0.03 160 XS6X160 1SCA101656R1001 0.04 180 XS6X180 1SCA101659R1001 0.04 250 XS6X250 1SCA101660R1001 Switches for PV applications rdering information 37

TDC100 800 ordering information Accessories HY_ Pistol handles H_ handles for front operation: IP 65, NEMA 1,3R, 12 Padlockable with three padlocks in -position, door interlock in -position. Screw fixing from the back side of the handle ensures double insulation. HB_ Handle Suitable Weight/ length for unit Colour [mm] switches Type rder number [kg] or shaft diameter 6 mm, indication in types HB and HY: I-0, -, in types HG: I-0. Black 65 TDC100...250E_, TDC100...200U_ HB65J6 1SCA022380R9660 0.12 Yellow-red 65 TDC100...250E_, TDC100...200U_ HY65J6 1SCA022380R9820 0.12 Grey 65 TDC100...250E_, TDC100...200U_ HG65J6 1SCA022380R9740 0.12 Black 80 TDC100...250E_, TDC100...200U_ HB80J6 1SCA022381R0240 0.14 Yellow-red 80 TDC100...250E_, TDC100...200U_ HY80J6 1SCA022381R0410 0.14 Grey 80 TDC100...250E_, TDC100...200U_ HG80J6 1SCA022381R0320 0.14 or shaft diameter 6 mm, indication: Test--/Test-0-I Black 65 TDC100...250E_, TDC100...200U_ HB65J6T 1SCA022399R8110 0.12 Yellow-red 65 TDC100...250E_, TDC100...200U_ HY65J6T 1SCA022456R9540 0.12 or shaft diameter 12 mm, indication HB and HY: I-0, -, in types HG: I-0 Black 95 TDC315...800E, TDC250...600U_ HB95J12 1SCA022381R0830 0.16 Yellow-red 95 TDC315...800E, TDC250...600U_ HY95J12 1SCA022381R1050 0.16 Grey 95 TDC315...800E, TDC250...600U_ HG95J12 1SCA022381R0910 0.16 Black 125 TDC315...800E, TDC250...600U_ HB125J12 1SCA022381R1560 0.17 Yellow-red 125 TDC315...800E, TDC250...600U_ HY125J12 1SCA022381R1720 0.17 Grey 125 TDC315...800E, TDC250...600U_ HG125J12 1SCA022381R1640 0.17 Black 145 TDC315...800E, TDC250...600U_ HB145J12 1SCA022381R2110 0.17 or shaft diameter 12 mm, indication: Test--/Test-0-I Black 95 TDC315...800E, TDC250...600U_ HB95J12T 1SCA022736R1750 0.16 Yellow-red 95 TDC315...800E, TDC250...600U_ HY95J12T 1SCA022736R1910 0.16 Black 125 TDC315...800E, TDC250...600U_ HB125J12T 1SCA022652R2220 0.16 Yellow-red 125 TDC315...800E, TDC250...600U_ HY125J12T 1SCA022652R2310 0.16 Door interlocking in -position means that the door cannot be opened when the handle is in -position. This can be defeated in IP65 types to allow authorized personnel access for inspection. NEMA 4, 4x pistol handles available on request. Handles padlockable in all positions available on request. H_ handles for side operation: IP 65, NEMA 1,3R, 12 or mounting on the side of the enclosure. Padlockable with three padlocks in the -position, door interlock in the -position, IP 65. The position indications are rotated 90. Handle Suitable Weight/ length for unit Colour [mm] switches Type rder number [kg] Side operation: for shaft diameter 6 mm, indication in types HB and HY: I-0, -, in types HG: I-0. Plastic handles Black 65 TDC100...200U_S HB65J6E00S 1SCA022382R9850 0.12 Red-yellow 65 TDC100...200U_S HY65J6E00S 1SCA022382R9930 0.12 Grey 65 TDC100...200U_S HG65J6E00S 1SCA022383R4510 0.12 Side operation: for shaft diameter 6 mm, indication: Test/I-/-, grey: Test/I- Black 65 TDC100...200U_S HB65J6TE00S 1SCA109016R1001 0.12 Red-yellow 65 TDC100...200U_S HY65J6TE00S 1SCA022688R0140 0.12 Grey 65 TDC100...200U_S HG65J6TE00S 1SCA109014R1001 0.12 Side operation: for shaft diameter 12 mm, indication I-/- Plastic handles Black 145 TDC250 400U_S HB145J12E00S 1SCA022679R9700 0.17 38 rdering information Switches for PV applications