EPA Method RSK 175 Dissolved Gasses in Water Matrices using the Teledyne Tekmar HT3 Headspace Analyzer. HT3 Application Note.



Similar documents
1.1 This test method covers the qualitative and quantitative determination of the content of benzene and toluene in hydrocarbon wax.

Transformer Oil Gas Analysis

PLOT Columns. Top: Bob Langford, GC Column Manufacturing Technician Bottom: Stephanie Sunner, Customer Service Representative

ACETALDEHYDE and ISOVALERALDEHYDE (Gas Chromatography)

23 The Thermal Conductivity Detector

Chemistry 321, Experiment 8: Quantitation of caffeine from a beverage using gas chromatography

ADVANCEMENTS IN MICRO GAS CHROMATOGRAPHY (GC)

Clarus 580 Gas Chromatograph

Chemical Analysis. Natural Gas Analyzer. A Family of optimized GC Solutions. Gas Chromatography. think forward

EnAlgae SOP: Biogas analysis

The Characterization of Perfume Fragrances Using GC/MS, Headspace Trap and Olfactory Port

Pilot Gasifier Producer Gas Analysis and Measurement Arrangements in. University of Applied Sciences

Determination of Haloacetic Acids and Dalapon in Drinking Water by SPE and GC/ECD*

Extraction of Cannabinoids in Marijuana and Edibles by QuEChERS

Addressing the World Helium Shortage For Gas Chromatography

With proper calibration, the upper limit may be extended as needed.

Chromatograph Maintenance and Troubleshooting Class # 5050

HPLC Analysis of Acetaminophen Tablets with Waters Alliance and Agilent Supplies

COMBUSTIBLE GAS AND HC REFRIGERANT LEAK DETECTOR OPERATING INSTRUCTIONS DETECTS ALL HYDROCARBON & OTHER COMBUSTIBLE GASES JB INDUSTRIES

Get the Right GC for Your Industry

Analysis of Organophosphorus Pesticides in Milk Using SPME and GC-MS/MS. No. GCMS No. SSI-GCMS Shilpi Chopra, Ph.D.

CONFIRMATION OF ZOLPIDEM BY LIQUID CHROMATOGRAPHY MASS SPECTROMETRY

Series 2. Air Server. Options for UNITY 2. A robust, cryogen-free solution for round-the-clock on-line air monitoring

Gas Chromatography. Let s begin with an example problem: SPME head space analysis of pesticides in tea and follow-up analysis by high speed GC.

METHOD 8020A AROMATIC VOLATILE ORGANICS BY GAS CHROMATOGRAPHY

Agilent 7697A Headspace Sampler Data Sheet

Analysis of Liquid Samples on the Agilent GC-MS

FORENSIC TOXICOLOGY LABORATORY OFFICE OF CHIEF MEDICAL EXAMINER CITY OF NEW YORK. VOLATILES ANALYSIS by GCMS HEADSPACE ANALYSIS

Request for Quotes Goods/Trade Services RFQ for Gas Chromatograph Mass Spectrometer (GCMS) (PCS# RFQ)

DGA - Method in the Past and for the Future

Background Information

AN INTRODUCTION TO HEADSPACE SAMPLING IN GAS CHROMATOGRAPHY FUNDAMENTALS AND THEORY. Andrew Tipler

GC/MS Analysis of Vanillin and Ethyl Vanillin in Distilled Spirits

On-line Dissolved Gas Analysis

Waters Corporation. Waters 2690/5 USER & TROUBLESHOOTING GUIDE

CHROMOCTANE O N LINE ANALYZER

SRI Product Index. Popular GC Configurations Choose from our pre conigured GC models for common applications.

Natural Gas Processing Solutions Using the 700XA Gas Chromatograph

Hydrogen as an alternative to Helium for gas chromatography.

This study was performed by Patrick Sullivan and staff at TestAmerica Analytical Testing Corp., Westfield, MA, USA

THERMAL DESORPTION. Introduction and Principles. Focusing on Volatiles

Expectations for GC-MS Lab

How To Run A Gas Plant

Enhancing GCMS analysis of trace compounds using a new dynamic baseline compensation algorithm to reduce background interference

SCION SQ Series GC-MS

GCxGC COUPLED TO FAST SCANNING QUADRUPOLE MS FOR TRACE ANALYSIS OF POPs

ß-CYCLODEXTRIN SYNONYMS

TANNIC ACID. SYNONYMS Tannins (food grade), gallotannic acid, INS No. 181 DEFINITION DESCRIPTION

A Comparison between EPA Compendium Method TO- 15 and EPA Method 8260B for VOC Determination in Soil Gas

GC METHODS FOR QUANTITATIVE DETERMINATION OF BENZENE IN GASOLINE

How To Test For Contamination In Large Volume Water

An Advanced Base Deactivated Capillary Column for analysis of Volatile amines Ammonia and Alcohols.

Gas Separations: A Comparison of GasPro and Aluminum Oxide PLOT Columns for the Separation of Highly Volatile Compounds

Method development for analysis of formaldehyde in foodsimulant. melamine-ware by GC-MS and LC-MS/MS. Internal Technical Report

Thermal Conductivity Detector

Fundamentals of Gas Chromatography

SCION GC Series. Innovation with Integrity. The Gas Chromatographers Choice for Separations GAS CHROMATOGRAPHY

Bioremediation of Petroleum Hydrocarbons and Chlorinated Volatile Organic Compounds with Oxygen and Propane Gas infusion

CRYOCOOLER CONTAMINATION STUDY. S.W.K. Yuan, D.T.Kuo, and A.S. Loc. BEI Technologies, Cryocooler Group Sylmar, CA ABSTRACT

Petrochemical Industry Ethylene Plant

1.2 This TAP is applicable to concrete, charcoal, coral, debris, wipes and soil.

Thermo Scientific ConFlo IV Universal Interface

Fast Continuous Online Analysis of VOCs in Ambient Air using Agilent 5975T LTM GC/MSD and Markes TD

Bringing Innovations to Standards AC Analytical Controls by PAC All In One Biodiesel Analyzer

BTU ANALYSIS USING A GAS CHROMATOGRAPH

The Use of Hydrogen Carrier Gas for GC/MS

Hands-on Workshop on Advanced Hydrocarbon Analysis July 23, 2015

On-line Ozone Precursor Analyzers From the Leader in Thermal Desorption Technology

AMD Analysis & Technology AG

Fractional Distillation and Gas Chromatography

Theory and Instrumentation of GC Introduction

Split / Splitless Injection for Capillary GC

Analysis of Phthalate Esters in Children's Toys Using GC-MS

Danalyzer Model 700 Gas Chromatograph

GC Troubleshooting 10. How to use this Troubleshooting Help system GC Troubleshooting - Top Level Generic problem descriptions...

NWTPH-HCID. Hydrocarbon Identification Method for Soil and Water

SYNSPEC GC s ALPHA 115 and ALPHA 116

Ferda ORHUN Mineral Research and Exploration Institute of Turkey

Mass Spectrometry. Fundamental GC-MS. GC Considerations

Quantitative Evaluation of Perfume Fleuressence Samples using the znose

Accurate and Precise Automated Dilution and In-line Conductivity Measurement Using the AS-AP Autosampler Prior to Analysis by Ion Chromatography

Operating Hints for Using Split/Splitless Injectors

MATHESON REFINERY PROGRAM for Specialty Gas Supply. Experience the MATHESON Commitment to Supply Chain Excellence

LC-MS/MS Method for the Determination of Docetaxel in Human Serum for Clinical Research

Automation of Solid Phase Extraction and Column Chromatographic Cleanup

Determination of Food Dye Concentrations in an Unknown Aqueous Sample Using HPLC

HEXANES. Insoluble in water, soluble in ether, alcohol, and acetone. Neutral to methyl orange (ph indicator) Not more than 0.

Validation and Calibration of Analytical Instruments a D.Gowrisankar, b K.Abbulu, c O.Bala Souri, K.Sujana*

Micromass LCT User s Guide

Appendix 5 Overview of requirements in English

Analysis of Free Bromate Ions in Tap Water using an ACQUITY UPLC BEH Amide Column

Cannabis Analysis: Potency Testing Identification and Quantification of THC and CBD by GC/FID and GC/MS

SUCRALOSE. White to off-white, practically odourless crystalline powder

IFC. A new perspective i l ifi ti. p p g p. Single softw FractPAL software plug-in for Agilent ChemStation. Medicinal Chemistry.

Question Bank Organic Chemistry-I

# LCMS-35 esquire series. Application of LC/APCI Ion Trap Tandem Mass Spectrometry for the Multiresidue Analysis of Pesticides in Water

Transcription:

EPA Method RSK 175 Dissolved Gasses in Water Matrices using the Teledyne Tekmar HT3 Headspace Analyzer HT3 Application Note Introduction The analysis of dissolved gases in ground water is important in determining whether intrinsic bioremediation is occurring in a fuel contaminated area. The gases of concern include methane, ethane, and ethylene. These compounds are used to detect biodegradation in areas of concern such as landfills and remediation sites. Presence of the compounds is used to determine if natural contaminant attenuation and destruction are occurring at a specific site. For example, fuel hydrocarbons will break down to methane and chlorinated solvents will reduce to form ethylene and chloride (1). Previous techniques for the analysis of dissolved gases used direct injections into the gas chromatograph. The water sample would be in a sealed vial with a certain amount of headspace. The vial would be heated and/or agitated to drive the gases into the headspace. The headspace was removed with a syringe and injected into the gas chromatograph. The Teledyne Tekmar HT3 is a Static and Dynamic Headspace Autosampler for gas chromatographs. The HT3 automates the analysis, from heating and agitating the vial, to the injection of headspace into the GC. This application demonstrates the capability of the HT3 to analyze dissolved gases in water.

Experimental Gas standards were purchased from Scott Specialty Gases. One cylinder contained methane, ethane, ethylene, acetylene, propane, propylene, propyne, and n-butane all at a concentration of 15ppm. A 22mL headspace vial was filled completely with DI water and capped. 4mL of headspace was removed using high purity nitrogen. This was performed by inserting a needle through the septum as seen in figure 1. Figure 1 4mL of nitrogen was pulled into a syringe equipped with a shutoff valve as seen in figure 2.

Figure 2 The syringe filled with nitrogen was injected into the vial, displacing 4mL of the water as seen in figure 3. Figure 3 After the injection of nitrogen both the syringe and the needle are pulled out of the vial.

The air standard is pulled into the syringe (as seen in figure 4) and injected into the headspace vial. Figure 4 The HT3 Headspace Autosampler was connected to an Agilent 6890 GC with an FID detector. The GC column used was a Restek PLOT column (Rt-U PLOT Catalog # 19726). The column gives excellent resolution and peak separation; however the two gases propane and propylene co-elute on the column and are integrated as one peak. A 5mL headspace loop was installed on the HT3 to inject a higher volume of mass into the GC injection port. The HT3 and GC parameters are listed below: Figure 5 HT3 Parameters Variable Value Variable Value Constant Heat Time On Mixing Time 2.00 min GC Cycle Time 22.00 min Mixing Level Level 5 Valve Oven Temp 80 degrees C Mixer Stabilize Time 1.00 min Transfer Line Temp 80 degrees C Pressurize 6 psig Standby Flow Rate 50 ml/min Pressurize Time 2.00 min Platen/Sample Temp 40 degrees C Pressurize Equil. Time 0.20 min Platen Temp Equil. Time 0.00 min Loop Fill Pressure 4 psig Sample Equil. Time 10.00 min Loop Fill Time 2.00 min Mixer On Inject Time 1.00 min

Figure 6 GC Parameters Variable Value Oven Temp. 50 degrees C to 190 degrees C @ 10/min Inj./Det. Temp. 250 degrees C Carrier Gas Helium Column Flow 5 ml/min Split Ratio 5:1 Results Two calibration curves were generated, one in the ppm range and one in the ppb range. The curve in the ppm range was calibrated from 0.5ppm to 4.0ppm and the curve in the ppb range was calibrated from 40ppb to 400ppb. The two curves are shown below: Figure 7 ppm Range Curve (0.5ppm to 4.0ppm) Compounds RF 1 RF 2 RF 3 RF 4 RF 5 %RSD Methane 0.89 1.00 0.88 0.69 0.65 17.84 Ethylene 0.85 1.00 1.03 0.99 0.94 7.22 Ethane 0.94 1.11 1.16 1.10 1.05 8.03 Acetylene 0.35 0.38 0.40 0.42 0.41 6.70 Propane/Propylene 2.45 3.02 3.16 3.04 2.89 9.51 Propyne 0.25 0.27 0.31 0.33 0.33 12.72 n butane 1.53 1.91 2.05 2.03 1.99 11.17 Figure 8 ppb Range Curve (40ppb to 400ppb) Compounds RF 1 RF 2 RF 3 RF 4 %RSD Methane 0.1182 0.1062 0.1049 0.0876 12.07 Ethylene 0.1127 0.1200 0.1187 0.1154 2.84 Ethane 0.1306 0.1410 0.1432 0.1401 4.02

Acetylene 0.0324 0.0349 0.0326 0.0324 3.68 Propane/Propylene 0.2868 0.3397 0.3676 0.3622 10.88 Propyne 0.0265 0.0230 0.0233 0.0244 6.47 n butane 0.1577 0.2348 0.2410 0.2540 19.63 Figure 9 Chromatogram of a 200ppb Gas Standard in Water Propane/ n- But Met Eth ylen Eth ane Acety Pro pyn Conclusion The analysis of dissolved gases such as methane, ethylene, ethane, acetylene, propane/propylene, propyne and n-butane proved to be a success on the HT3 Headspace analyzer. The analysis of these compounds in water would be critical for determining biodegradation of a contaminated site. This application describes the technique needed for the sample and standard preparation for Method RSK-175. Because of the HT3 electronic pressure and flow control, identical loop fill and injection into the GC produced excellent %RSD s. Preparation of samples and standards are a key factor in the method, so syringes with shut-off valves must be used for the analysis. References

1. Don H. Kampbell and Steve A. Vandegrift. Analysis of Dissolved Methane, Ethane, and Ethylene in Ground Water by a Standard Gas Chromatographic Technique. Journal of Chromatographic Science, Vol. 36, 253-256 May 1998