Dual Technology Ceiling Mount Sensor



Similar documents
2.0 Installation 1. Remove the cover using a small flat blade screwdriver. Figure 2: Cover Removal

Installation Manual. Features SMART SWITCH OCCUPANCY SENSOR. Maximum Energy savings

EcoSystem Dimming Power Module for 3-wire Lutron Dimming Ballasts. EcoSystem One-Line. EcoSystem C5-BMJ-16A. EcoSystemR Dimming Module

How To Use A Lutron Power Supply

LOS 2500 SUPER CEILING SENSOR. Installation Manual

High Bay Occupancy Sensor Selection Guide

HomeWorks QS Processor

Lighting Management solutions

QSE-CI-DMX Control Interface

INSTALLATION INSTRUCTIONS

Installation Instructions

HERZ-Thermal Actuators

Control Interfaces. GRAFIKR Systems a LUT-DMX

GRX-PWM Pulse Width Modulation Interface

IS3016A Passive Infrared Motion Sensor with Anti-Mask - Installation Instructions

QSE-CI-NWK-E Control Interface

LANTANA LUMINAIRE HI-LUME 1% ECOSYSTEM LED DRIVER L3DA4U1UMN-XXXXX

APPLICATION GUIDE MINI PRODUCT GUIDE

INSTALLATION/PROGRAMMING INSTRUCTIONS 928 ENTRYCHECK

Model 201 Wiegand Touchpad Reader Installation Guide

SECURITY CAMERA INSTRUCTION MANUAL ENGLISH VERSION 1.0 LBC

Applied Electronics. Commercial Dimming System UPDATE NOTICE

Digital Keypad Use s Manual

K9 Heat Alarm Owners Manual HA-1520

P10 - Standalone Access Controller and Reader

AUTOMATIC TRANSFER SWITCH CONTROL UNIT OPERATOR S MANUAL

5W LED Energy Saver PIR Bulkhead

Switching Power Module

EBDSPIR-PRM, EBDSPIR-PRM-IP

Duct Humidity Transmitter

Installation Guide. LR-HWLV-HVAC TouchPRO Wireless. System Types

Detector transparent with Color Inserts. FAA 500 TR P Trim Ring transparent with Color Inserts. FCA 500 / FCA 500 E Detector Bases

Infrarot-Bewegungsmelder IP44

Programmable Room Thermostat 7 Day (5-2 Day) Models: / Power Supply: Battery / Mains

Dome Camera with IR Night Vision

FIRERAY 2000 Installation Guide

AC-115 Compact Networked Single Door Controller. Installation and User Manual

SWITCH! DESCRIPTION. ENVIRONMENTAL SPECIFICATIONS Operating Temperature: 0 C to +40 C SPECIFICATION SHEET:

Installation Guide. VisionPRO. TH8000 Series. Need Help? This manual covers the following models. System Types

OPERATING PRINCIPLES FOR PHOTOELECTRIC SENSORS

DUAL SENSING DIGITAL THERMOSTAT PRODUCT INSTRUCTIONS. Construction Automotive Industry

Lighting Controls ! WARNING RISK OF ELECTRIC SHOCK. Installation Instructions DESCRIPTION

2M IR Mini Dome Quick Installation Guide

LED MOTION ACTIVATED FLOOD LIGHT

REB 1 REB 3 REB 5 REB 6 REB 8 REB 10 REB 12 REB 16

INSTALLATION INSTRUCTIONS

GeekDesk Max Instructions for Assembly & Use

Owner s Manual AWM910 JENSEN AWM910 COMPACT DISC PLAYER RADIO CD COMPACT MUSIC SYSTEM MUTE AUX BAND AUX IN PUSH PUSH PWR VOL ALARM T/F AUD SPK A SPK B

DC1100 & 1400 Energy Controllers. Satchwell DC1100 & DC1400 for energy-efficient temperature control in smaller buildings.

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930

Radiant Temperature Sensor TY7321

How To Power A Power Control On An Ip40 (Ipl) With A Power Supply (Iplug) With An Ip20 Controller (Iphones) With Power Control (Power Control) With No Antenna) With The Ip20 (Power)

T7560A,B,C Digital Wall Module

ABB Stotz-Kontakt GmbH ABB safe&smart Project planning of security systems

Lighting Control in the Office Space

PASSIVE INFRARED INTRUSION DETECTOR PASSIVE INFRAROOD DETECTOR DETECTEUR D INTRUSION PASSIF INFRAROUGE

FL ballasts Electronic dimming. PCA T5 BASIC lp Y II, W BASIC T5

Please read this owner s Manual carefully before operating the unit. - Cooling - Heating - Dehumidifying - Fan

KCIEN KCIENSBP. Heavy Duty Stainless Steel Illuminated Keypads INSTALLATION MANUAL. Range: DIGICODE (Stand-Alone Keypad)

650W Single Output Power Supply

LED MOTION ACTIVATED FLOOD LIGHT

Motion Activated Camera User Manual

TAC I/NETTM MR-VAV-AX. Application Specific MicroRegulator TM

MOTION SENSOR PIR LIGHT SWITCH INSTALLATION & OPERATING. Cat No. ZV810 INSTRUCTIONS

LUCCI AIRFUSION QUEST II CEILING FAN

Contractors Guide Central Inverter System Installation

Operating Instructions. Room temperature controller

LP Dimming Panels. GRAFIK Systems. Power Equipment. LP Dimming Panels

Auto Dialer. Manual E-921APQ E-921GPQ

EBDSPIR-DD, EBDSPIR-DD-IP

Electronic Control Devices The European Product Catalogue 2007

2013 Wireless Video Intercom INSTALLATION GUIDE

VX 2400 Dimmer User's Manual

HCS-3300/3302/3304 USB Remote Programmable Laboratory Grade Switching Mode Power Supply

2400W PIR LIGHT C O N T R O L L E R Cat No. SLW2400

HAM841K ALARM CONTROL PANEL FOR COMMERCIAL AND RESIDENTIAL SECURITY SYSTEMS

Modular Room Control (MRC) Series Digital Thermostat

TABLE 1: Wiring Terminals. Connect to... 1C 1H 2C 2H 1H1C 2H1C 2H2C 3H2C

INSTALLER S & OWNER S MANUAL

T-SERIES INDUSTRIAL INCLINOMETER ANALOG INTERFACE

DALI Power Module (LQSE-2DAL-D) DALI Bus 1. DALI Bus 2. HomeWorks. Wallstation. Power. Eye QS Control Power Up to 100. Module.

INSTALLATION INSTRUCTIONS

INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks

DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS

sensors Miniature Sensors - S100 The universal miniature photoelectric sensor

Digi-Motor Installation Guide

1000W Single Output Power Supply 15V 24V. Protection type: Total Power limit, Latch-style (Recovery after reset AC power ON or inhibit)

e-ask electronic Access Security Keyless-entry

GSM AD05 Slave GSM Auto Dialer- Instruction Manual

60W PIR BULKHEAD LIGHT SLB88-Black/SLW89-White INSTALLATION & OPERATING INSTRUCTIONS

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

USER GUIDE. Studio Hotline Multi-line System Phone Flasher and Door/Alert Indicator Input Module and Indicator. DM Engineering. Version 1.

GLPAC-DIMFLV Crestron Green Light Integrated Lighting System

Installing the Tracer ZN517 Unitary Controller Ordering number: ,

FIREDEX Conventional Fire Panels

Cross-beam scanning system to detect slim objects. 100 mm in

Solid State Timers Type F

T5000 T000 LCD Digital Fan Coil Thermostat

IPThermo206G. Offline/online data collector, SMS alarm sender, watchdog terminal for IPThermo Pro network

MTS Power Products MIAMI FL ATS-22AG. Automatic Transfer Switch And Control PLC Operator s Manual

Transcription:

369652b 1 05.04.12 Dual Technology Ceiling Mount Sensor The ceiling-mount dual-technology sensors can integrate into Lutron systems or function as stand-alone controls using a Lutron power pack. The technology eliminates manual sensitivity and timer adjustments during installation and over the life of the product. Features Intelligent, continually adapting sensor Ultrasonic (US) combined with passive infrared (PIR) sensing provide high sensitivity, high noise immunity, and excellent false tripping immunity Suited for complex environments that are difficult to control with single-technology sensors Snap-locks to ceiling-mounted cover plate Non-Volatile Memory: settings saved in protected memory are not lost during power outages 500 to 2000 sq ft (46 to 186 m 2 ) coverage when mounted on an 8-12 ft (2.4 to 3.7 m) ceiling; 180 and 360 field of view Affords choice of turning lights off or dimming to a preset level in the unoccupied state when integrated with a Lutron system. Assembled in the USA. Models Available Cat. No. Color Coverage Field of View ULOS-CDT-500-WH White 500 sq ft (46 m 2 ) 180 ULOS-CDT-500R-WH White 500 sq ft (46 m 2 ) 180 ULOS-CDT-1000-WH White 1000 sq ft (93 m 2 ) 180 ULOS-CDT-1000R-WH White 1000 sq ft (93 m 2 ) 180 ULOS-CDT-2000-WH White 2000 sq ft (186 m 2 ) 360 ULOS-CDT-2000R-WH White 2000 sq ft (186 m 2 ) 360 Self-Adaptive Feature The ceiling-mount occupant sensors combine both (US) motion detection for maximum sensitivity and passive infrared (PIR) motion detection for false triggering immunity. The self-adapting internal microprocessor analyzes the composite sum of both signals to eliminate time-consuming adjustments and callbacks found in non-intelligent sensors.

Specifications 369652b 2 05.04.12 Timer Adjustment Automatic mode: Continually adapting sensor automatically adjusts settings to the space Manual mode: 8 to 30 minutes Test mode: 8 seconds LED Lamp : infrared motion detected Green: ultrasonic motion detected Housing Rugged, high-impact, injection-molded plastic Color-coded leads 6 in (15 cm) Power Operating voltage: 20-24 V, PELV (Class 2: USA) low-voltage Operating current: 33 ma nominal Control output: 20-24 V active high logic control signal with short-circuit protection, open collector when unoccupied Dimensions Measurements are in inches (mm) Operating Environment Temperature: 32 to 104 F (0 to 40 C) Relative humidity: less than 95%, non-condensing For indoor use only Adaptive Functions Installation: 60 minutes Learning: 4 weeks for response to error conditions, air current adaptation, and timer optimization Post-learning occupancy periods 24-hour circadian occupancy periods learned Weekly occupancy periods learned Adjustments in post-learning period Generally occupied periods (threshold = high-sensitivity mode) Generally unoccupied periods (threshold = miser mode) Contact Rating (R Models only) SPDT 500 ma rated at 24 V isolated relay Photo Cell (R Models only) Prevents light from turning on when there is sufficient natural light Sensitivity: 0-1000 LUX adjustable 1.4 (38) 4.5 (114) Front View Side View

Wiring Note: Power pack may be required when interfaced to lighting control system; see below. 369652b 3 05.04.12 Single Sensor to System 2 or More Sensors to System control system (+20-24 V ) Blue* (signal) Black (common) control system (+20-24 V ) Blue* (signal) Black (common) To additional sensors, maximum determined by lighting controller *Note: Use gray wire for -R model. Power Supply Options Lutron Control System Digital microwatttm EcoSystem GRAFIK 5000 / 6000 / 7000TM GRAFIK Eye 3000 / 4000 HomeWorks LCP128TM microwatt RadioRA RadioTouch Softswitch128 Power Pack Required? No No No, when used with seetouch wallstations with occupant sensor connections. Yes Yes No, when used with seetouch wallstations with occupant sensor connections. No Yes No No, when used with seetouch wallstations with occupant sensor connections. NOTE: Power Pack may be required for more than one Occupant Sensor. Consult factory for multiple sensor requirements.

Wiring: Stand-Alone Control 369652b 4 05.04.12 1 to 3 Sensors with Power Pack 120 / 277 / 347 V 60 Hz; 230 V 50 / 60 Hz Hot Neutral (+20-24 V ) Blue* (signal) Black (common) Note: Maximum 3 occupant sensors. Power Pack Black White Manual switch off (optional) Load Switching Multiple Loads with Auxiliary Power Packs Hot Manual switch off (optional) 120 / 277 / 347 V 230 V 60 Hz; 50 / 60 Hz Neutral Load Auxiliary Power Pack Note: Maximum of 3 devices total (occupant sensors and auxiliary power packs) can be connected to a power pack. (+20-24 V ) Blue* (signal) Black (common) Power Pack Black White Load *Note: Use gray wire for -R model.

Wiring Relay Model Option LOS-CDT-xxxxR only (+20-24 V ) 369652b 5 05.04.12 Control system* Gray (control: occupancy and photo cell signal) Blue: Cap off Black (common) Gray wire logic with photo cell active: Room First Occupied During Occupancy Light level: Lights: Light level: Lights: Below set value Turn on Falls below set value Turn on Above set value Remain off Moves above set value Remain on *Note: May require power pack Yellow/White (NO) Choose wire based on functionality): Yellow/White: NO (normally open) Open: Unoccupied Closed: Occupied Black/White: NC (normally closed) Open: Occupied Closed: Unoccupied Cap off unused wire. Black/White (NC) Blue/White (Relay, Common)

Installation Sensor Placement 369652b 6 05.04.12 The occupant sensor must have an unobstructed view of the room. Do not mount behind or near tall cabinets, shelves, indirect hanging fixtures, etc. Do not place sensor within 6 ft (1.8 m) of air vents, air handlers, windows, fans, etc., as this may cause false triggering. If installing a 180 occupant sensor (500 and 1000 models), place the sensor on the same wall as the doorway so that traffic in a hallway will not affect the sensor; otherwise, place in center of room. Closely follow the diagrams shown concerning major and minor motion coverage. The sensor can detect major motion (such as a person taking a half-step) at a greater distance than it can detect minor motion (such as writing or typing at a desk). Decrease total coverage area by 15% for soft rooms (for example, heavy draperies or heavy carpeting). Range Diagrams 22 ft (6.7 m) 16 ft (4.9 m) 32 ft (9.8 m) 23 ft (7 m) 23 ft (7 m) 32 ft (9.8 m) 23 ft (7 m) 32 ft (9.8 m) 12 ft (3.7 m) 22 (6.7) LOS-CDT-500 12 ft (3.7 m) 22 ft (6.7 m) LOS-CDT-1000 64 ft (19.5 m) 45 ft (13.7 m) Major motion detection Minor motion detection 23 ft (7 m) 32 ft (9.8 m) 12 ft (3.7 m) 22 ft (6.7 m) LOS-CDT-2000

Installation 369652b 7 05.04.12 Mounting Normal Mounting Twist and lock threaded mounting post onto cover plate. Drill through ceiling tile with assembly, using cutter end of the threaded mounting post. Secure with washer and nut. Mounting to Non-Standard Ceiling or Fixture Mount twist-lock cover plate using mounting screws, nuts, and washers (included). Drill/punch wire routing hole through ceiling tile at center of cover plate. 13/16 in (21 mm) Cutter end Wire Lengths # Sensors 1 2 3 1 2 1 # Aux. PP 0 0 0 1 1 2 22 AWG 750 ft 375 ft 250 ft 375 ft 250 ft 250 ft 0.5 mm 2 365 m 180 m 120 m 90 m 120 m 120 m 20 AWG 1200 ft 600 ft 400 ft 600 ft 400 ft 400 ft 0.75 mm 2 730 m 365 m 240 m 365 m 240 m 365 m 18 AWG 2400 ft 1200 ft 800 ft 1200 ft 800 ft 800 ft 2.5 in (63 mm) Mounting Plate Dimensions.52 in (13.3 mm) 4.2 in (106.6 mm) Using the Infrared Mask Typical Mask Patterns Conference Room Mask 180 Mask Full Mask Center Ceiling Mount (Mask blocks sensor seeing out doorway into hall) Corner Ceiling Mount (No mask needed) Rectangular Areas Over the Door Specific Areas You Wish to Mask

369652b 8 05.04.12 Sensor Adjustments Override Settings Auto/Manual Threshold LED Motion Indicator Reset Learned Settings A 1 2 3 4 ON Off (Default) Automatic (Normal) Auto Threshold Adjustment Lights indicate motion Retain Settings (Normal) On Manual on/off (Override) High Sensitivity (Low turn-on threshold) Disable LED Indicator Erase all learned settings, restart Learning (Toggle On) Strong Airflow Compensation Over Doorway Installation Timer Adjust Auto Sensitivity B 1 2 3 4 ON Off On Disable Compensation (Normal) Enable Compensation No (Normal) Yes (Use increased turn-on threshold) Adjust Timer Automatically Use Manual Setting (No adjustment) Adjust Sensitivity Automatically Adjust Sensitivity Manually Timer Test Mode Factory Settings 1. Remove the retainer cover. 2. Rotate the black timer adjustment knob to about midway (12 o clock). 3. Return setting to minimum setting (full CCW). Factory Settings 12 o clock Full CCW : Infrared sensitivity 75% default Black: Timer 8 min. A 1 2 3 4 ON B 1 2 3 4 ON Green: Ultrasonic range 50% default Blue: Photo cell (R model only) 100% default Note: The timer will remain in the 8-second test mode for 1 hour, then automatically reset to 8 minutes. 4. To manually take the timer out of the 8-second test mode, turn the timer adjustment approximately 1/16 in (1.5 mm) clockwise to make the setting slightly above minimum (just above the 8-minute setting).

Installation 369652b 9 05.04.12 Adjusting the Lights Not On Level ULOS-CDT-xxxxR only 1. Place timer in Test Mode (see page 7). 2. Set photo cell to max. Turn the blue knob full clockwise (lights on no matter how bright the natural light is), then about 30 degrees counterclockwise. 3. Check for Lights-Out. Move from underneath the sensor, and remain still until the lights turn off. Move around normally to turn the light on. 4. Adjust to desired level. If lights remain off, adjust the blue knob another 30 degrees counterclockwise and repeat step 3 until the lights turn on. Note: Set blue knob to 100% to disable photo cell functionality and leave secondary dry contact closure output functionality intact. Control Settings (Blue Knob) ULOS-CDT-xxxxR only Minimum (low): Lights will never come on, even though room is occupied. 0 1000 0 1000 0 1000 Maximum (high): Photo cell has no effect on operation (factory setting). Normal: 200 to 600 LUX is normal range.