12VDC MAGNETIC ED DIMMABE POER SUPPIES SPEC SEET DIGEST TM-30-DIM TM-50-DIM T-60-DIM TM100-DIM TM200-DIM TM300-DIM iring Diagram for TM-50-DIM and TM-100-DIM
ED 12VDC MAGNETIC DIMMABE 30 POER SUPPY Smallest dimmable Class II hardwire ED dimming magnetic power supply on the market that works with conventional low voltage magnetic wall mount dimmer Features include high efficiency, excellent load regulation and no wattage de-rating under 100% load. There is no minimum load requirements for this transformer/driver. construction enclosure. Enclosure temperature should not exceed 70 C (158 F) @ 40 C (104 F) ambient. iring compartment has 2 knockouts sized for 3/4 screw cable conductors. Removable cover for wiring compartment is secured in place clips and one screw. Black powder coated. Electrical: Input and output terminals are terminal block. Input leads are 20 AG. Output leads are 16 AG. ead insulation rated to 105 C (221 F). Transformer utilizes a class B 130 C (266 F) insulation system. Maximum load is 30. Coil former is double section bobbin. Auto reset. Dimming: orks with low-voltage magnetic wall dimmer Mounting: Surface mount with front mounting tab. arranty: 4 years. abel: ET listed for indoor and outdoor use. Catalog Max. Input Output eight Dimensions Number attage Voltage Voltage TM30-DIM 30 120V/60z 12VDC 2.0 lb. 6.03 1.98 1.43 For voltage drop - see www.gmlighting.net/voltagedrop.html or consult GM ighting Product catalog, page 19. TM30-DIM_100312
ED 12VDC MAGNETIC DIMMABE 50 POER SUPPY Smallest dimmable Class II hardwire ED dimming magnetic power supply on the market that works with conventional low voltage magnetic wall mount dimmer No minimum load (can be fully loaded). Auto reset thermal circuit breaker on the secondary side. construction enclosure. Enclosure temperature should not exceed 70 C (158 F) @ 40 C (104 F) ambient. iring compartment has 2 knockouts. Removable cover for wiring compartment is secured in place screw. Black powder coated. Electrical: Thermal class B-130C. Input leads are 20 AG. Output leads are 16 AG. ead insulation rated to 105 C (221 F). Transformer utilizes a class B 130 C (266 F) insulation system. Maximum load is 50. Coil former is double section bobbin. Auto reset. Dimming: orks with low-voltage magnetic wall dimmer Mounting: Surface mount with front mounting tab. arranty: 4 years. abel: ET listed for indoor and outdoor use. Catalog Max. Input Output Input Open Output eight Dimensions Number attage Voltage Voltage Current Circuit Current TM50-DIM 50 120V/60z 12VDC 410mA 12.5V 4A 3.3 lb. 6.06 2.59 2.33 For voltage drop - see www.gmlighting.net/voltagedrop.html or consult GM ighting Product catalog, page 19. TM50-DIM_020412
12VDC / 24VDC ED MAGNETIC DIMMABE 60 POER SUPPY ED dimming magnetic power supply that works with conventional low voltage magnetic wall mount dimmer with on/ off switch. 12 or 24 VDC output. 120, 240 or 277 VAC input. No minimum load (can be fully loaded). ighest efficiency with auto reset. Not recommended for digital installations. Construction: Power supply is fully epoxy encapsulated for long life and to protect against moisture. Full metal enclosure. No external fusing required. Input and output wire color chart on side for easy reference. 2 knock-outs. 3-3/4 Electrical: Output voltage 12 or 24 VDC. Patented short circuit and overload protection. imited power source output allows for Class II wiring. Thermal class B-130C. Input leads are 20 AG. Output leads are 16 AG. ead insulation rated to 105 C (221 F). Transformer utilizes a class B 130 C (266 F) insulation system. Auto reset. 9/32 3 Dimming: orks with low-voltage magnetic wall dimmer Mounting: Mounting tabs allow direct screw mounting. 6-15/16 5-7/8 abel: ET listed for indoor use. Not rated for outdoor use. Tested to CAN/CSA C22.2 No. 60950-1-03 and EN 60950-1. Ros compliant. Not rated for outdoor use. Catalog Max. Input Output eight Dimensions Number attage Voltage Voltage T-60-DIM 60 120V, 240V 12 or 4.11 lbs. 6-15/16 3 3-3/4 or 277VAC / 50 or 60 z 24 VDC For voltage drop - see www.gmlighting.net/voltagedrop.html or consult GM ighting 2011 New Product Product Brochure, page 10. Specifications subject to change without notice. T-60-DIM_070611
ED 12VDC MAGNETIC DIMMABE 100 POER SUPPY Class II hardwire ED dimming magnetic power supply that works with conventional low voltage magnetic wall mount dimmer No minimum load (can be fully loaded). Auto reset thermal circuit breaker on the secondary side. construction enclosure. Enclosure temperature should not exceed 70 C (158 F) @ 40 C (104 F) ambient. iring compartment has 2 knockouts. Removable cover for wiring compartment is secured in place screw. Black powder coated. Electrical: Thermal class B-130C. Input leads are 20 AG. Output leads are 16 AG. ead insulation rated to 105 C (221 F). Transformer utilizes a class B 130 C (266 F) insulation system. Maximum load is 100. Coil former is double section bobbin. Auto reset. Dimming: orks with low-voltage magnetic wall dimmer Mounting: Surface mount with front mounting tab. arranty: 4 years. abel: ET listed for indoor and outdoor use. Catalog Max. Input Output Input Open Output Dimensions Number attage Voltage Voltage Current Circuit Current eight TM100-DIM 100 120V/60z 12VDC 898mA 12.5VDC 8.05A 6 lbs. 9.21 3.11 2.93 For voltage drop - see www.gmlighting.net/voltagedrop.html or consult GM ighting Product catalog, page 19. TM100-DIM_020412
ED 24VDC MAGNETIC DIMMABE 200 POER SUPPY A hardwire 200VA ED dimming magnetic power supply that works with conventional low voltage magnetic wall mount dimmer No minimum load (can be fully loaded). Manual reset thermal 14A circuit breaker on the secondary side. NEMA 3R rated enclosure. Enclosure temperature should not exceed 70 C (158 F) @ 40 C (104 F) ambient. iring compartment has 3 knockouts sized for 3/4 inch screw cable connectors. iring compartment cover is hinged with rivets and opens vertically from bottom to top. Black powder coated. Electrical: Thermal class B-130 C. Input leads are 18 AG. Output leads are 12 AG. ead insulation rated to 105 C (221 F). Transformer utilizes a class B 130 C (266 F) insulation system. Maximum load is 200. Dimming: orks with all dimmers that provide symmetrical form of the current under any conditions. Mounting: Surface mount with back mounting tab. arranty: 4 years. abel: U listed. U file number: E194005. Catalog Max. Input Output Input Open Output Dimensions Number attage Voltage Voltage Current Circuit Current eight TM200-DIM-24 200 120V/60z 24VDC 0.6A 24VDC 8.05A 9 lbs. 8 4.1 3.1 For voltage drop - see www.gmlighting.net/voltagedrop.html TM200-DIM-24_121012
ED 12VDC MAGNETIC DIMMABE 300 POER SUPPY A hardwire ED dimming magnetic power supply that works with conventional low voltage magnetic wall mount dimmer No minimum load (can be fully loaded). Manual reset thermal 4A circuit breaker on the primary side. construction enclosure. Enclosure temperature should not exceed 65 C (149 F) @ 40 C (104 F) ambient. iring compartment has 3 knockouts, sized for 3/4 screw cable connectors. iring compartment cover hinged with rivets and opens vertically from bottom to top. Black powder coated. Enclosure type: NEMA 3R Outdoor. Electrical: Thermal class B-130C. Input leads are 18 AG. Output leads are 16 AG. ead insulation rated to 105 C (221 F). Transformer utilizes a class B 130 C (266 F) insulation system. Maximum load is 300. Coil former is double section bobbin. Dimming: orks with low-voltage magnetic wall dimmer Mounting: Surface mount with front mounting tab. arranty: 4 years. abel: U listed for indoor and outdoor use. Catalog Max. Input Output Input Open Output Dimensions Number attage Voltage Voltage Current Circuit Current eight TM300-DIM 300 120V/60z 12 VDC 0.6A 12.5VDC 25A 9 lbs. 9.0 4 3 For voltage drop - see www.gmlighting.net/voltagedrop.html or consult GM ighting Product catalog, page 19. TM300-DIM_020412
For Model # TM-50-DIM and TM-100-DIM General This transformer is to be installed in accordance with Article 450 of the National Electric code. The transformer must be installed in a well-ventilated area free from explosive gases and vapors. Proper operation requires the free flow of air. Only a qualified electrician should install this hardwired transformer. Precautions Before Installing Check the label and ensure the transformer has the proper input voltage, output voltage and wattage for the job. Check the wire markings to ensure they match the wiring diagram on this instruction sheet. Mounting Select a suitable location capable of supporting the weight of the transformer. Use the two keyholes provided on the mounting flange. Input Connections/Grounding Remove the wiring compartment knockouts and install strain reliefs. ith power turned off, route the input wires through a strain relief and connect one wire to black and one wire to white. For all wire connections use only U listed wire nuts and connectors of suitable size and type. The transformer case MUST be grounded in accordance with the N.E.C. Connect the green wire transformer to ground. Output Connections Bring the 12 volt DC lamp wires through the open knockout and connect the positive (+) side to the red transformer wires, and negative (-) side to the blue transformer wires. Connect the 12V DC wire to the red and blue wires. Connect the red wire to the positive (+) side and the negative (-) wire to the blue side. Boost Tap This transformer is equipped with an optional 10% boost tap which can compensate for voltage drop between the transformer and the lighting fixture. If the fixtures are receiving 10.5 Volts or less, we recommend you connect the boost tap. To use the boost tap, the input wires are connected to the orange and white wire instead of the black and white wire. Make certain the black wire is capped with a wire nut if you use the boost tap. Make certain the orange wire is capped with a wire nut if you do not use the boost tap. INPUT IRES ITOUT BOOST TAP: Black & hite INPUT IRES IT BOOST TAP: Orange & hite GROUND IRE: Green OUTPUT IRES: Blue (-) & Red (+) 9830. 190th St. Unit F Mokena, I 60448 Toll-Free: (866) 671-0811 FAX: (708) 478-2640