Metal Clad Indoor Instrument Transformer for Plug-In Systems



Similar documents
Medium Voltage Instrument Transformers

Medium voltage product. Instrument transformers for indoor applications Product overview

The Intelligent AX1 Switchgear for Medium Voltage

MiCAFIL. 1 RIP Technology. Bushings. Z. Zic 09/2003

PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES

Pressure monitoring equipment for oil-sf 6. bushings, type GOEK

2a. IEM Indoor Metal Clad Medium Voltage Switchgear 15KV a. Section INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std.

Transformer Bushings for GIS

Takfan Machinery and Mould Co Ltd. Plug in Bushing. LV Monoblock. RMU Bushing. 4 Way CT Terminal.

Model 1756 Test Lead Kit

Earth Fault Detection Basics in Theory

High-Voltage Compact Switchgear 3AP1 DTC for 145 kv and 245 kv

KOLMA and IHDA Indoor type Cable Current Transformers Catalogue ABB Power Distribution ABB Transmit 1 KKOLMA 1 GB

Current & Instrument Transformers

CONNEX. The plug-in system for power transformers and gas-insulated switchgear.

Adaption of Cable Accessories for Onshore and Offshore Substation

MEDIUM AND HIGH VOLTAGE CAPACITORS, CAPACITOR BANKS AND SYSTEMS

How To Choose A Transformer

EDITION 2012 CABLE SYSTEMS

Medium-voltage transformers

ALTERNATIVE METHODS FOR INTERNAL ARC TESTS ON 12 KV AND 24 KV METAL-ENCLOSED SWITCHGEARS WITH COMPACT RMU

BETAtrans. Cables and Systems for Rolling Stock. Edition 2006

Power transformers. Special transformers Railway

Advantages of Fixed Circuit Breaker Switchgear

1ZSC AAC en, Rev. 7. Resin impregnated paper bushing, oil to air, type GSB Technical guide

Power Plant Electrical Distribution Systems

INTERNATIONAL POWER DISTRIBUTION CONGRESS CIDEL ARGENTINA 2002

a Nexans company Catalogue 2014

Trade of Electrician. Three-phase Distribution Boards And Socket Circuits

UniGear ZS1. Medium voltage, arc proof, air insulated switchgear for primary distribution

2. INDUCTIVE VOLTAGE TRANSFORMERS Oil-paper insulation Gas insulation

Disconnectors and Earthing Switches 36 kv up to 800 kv

DRM75A 230V 20/100A DIN rail single phase two wire energy meter

Safe and secure distribution of medium voltage with AX1

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV

EVC40 EMERGENCY VOICE COMMUNICATION SYSTEM

UFES Active protection for switchgear

FLUORESCENT UV- RING LIGHT OPERATING INSTRUCTION

Dead Tank Circuit Breaker 72PM40-C Proven reliability through common platforms

Our brand POWER DYNAMIC PASSION COMMITMENT CREATIVITY. A strong brand for strong products: 8PU Premium. MV Energy

Unified requirements for systems with voltages above 1 kv up to 15 kv

5SV Residual Current Protective Devices

SECTION POWER MONITOR FOR ELECTRICAL, STEAM CONDENSATE, AND WATER PART I - GENERAL

1ZSE en, Rev. 8. Transformer bushings, type GOE and GOE(2) Technical guide

SF 6 Gas Insulated Switchgear Type SDF for 170 kv

NATUS NES / NES-H Draw-out Type Medium Voltage Switchgear Systems. Safe energy distribution that meets the highest industrial requirements

Presentation of the France Transfo factories

T Substation Maintenance and Commissioning Test Equipment

Paper on Basbar Trunking System for Electrical Supply to Industrial & commercial Installation

Submit shop drawings for equipment provided under this section Shop drawings shall indicate:

Medium Voltage (MV) & High Voltage (HV) Training Module 6. Date of the presentation

CAS 36 Ring Main Unit

CABLE ACCESSORIES kv

Data Sheet VITOSOL 100. Flat collectors for the utilisation of solar energy. Vitosol 100. Part nos. and prices: see price list

Tape Wound, Split Core and Ebony Current Transformers

ADM1TE 5/30A DIN rail single phase two wire energy meter

Fundamentals of Modern Electrical Substations Part 1: Mission of Electrical Substations and their Main Components

understanding medium frequency induction melting furnace and its components

Hyperlinks are Inactive

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Instructions for Safe Use

TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: AW52AL AW64AL AW52AL AW64AL /05

Outdoor circuit breaker GVR Recloser Hawker Siddeley Switchgear. rated voltage 15, 27 and 38 kv rated current 630 A

Transformer oil cooler ALFA A02

SECTION DRY-TYPE TRANSFORMERS

LOW VOLTAGE RING TYPE MEASURING CURRENT TRANSFORMERS

Secondary Unit Substations

2013 RESIBLOC transformers Product presentation. ABB Group October 2, 2013 Slide 1

Tape Wound, Split Core and Ebony Current Transformers

Type-Tested Power Distribution Board 8PT with Rear Busbars. sivacon

No Heat. No Flames. No Shoving. No Special Tools. 3M Cold Shrink. 3M Cold Shrink. Medium Voltage Joints & Terminations. 3M Cold Shrink Joint

3 WATT LED SPOTLIGHT Model No. SLM

CURRENT TRANSFORMERS INSTALLATION GUIDE

RAILWAY CATENARY SYSTEMS. Components and Systems for the Electrification of Railway Lines. ibemo

Data Sheet PS1B Pressure Switch

INDUSTRY WIDE LABOR-MANAGEMENT SAFETY COMMITTEE SAFETY BULLETIN #23

Digital Energy ITI. Instrument Transformer Basic Technical Information and Application

Unit 4: Electricity (Part 2)

Technical data. RCBO s DS 261 / DS 271 Residual current operated circuit breakers with integral overcurrent protection

e-mobility Special cables for electric vehicles Coroplast Fritz Müller GmbH & Co. KG Tapes Cables Cable Assemblies

REVIEWED BY CAPITAL PROJECTS MANAGER (DAN REDDY) GENERAL MANAGER EQUIPMENT ENGINEERING & ASSET MANAGEMENT (HAMILTON NXUMALO)

Enhanced Quality with a Touch of Style

UGVCL/SP/591/11KV HT AB CABLE

(PREVIEW) Indian Standard COMMON SPECIFICATION FOR HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR STANDARDS

UNIVERSITY OF WASHINGTON Facilities Services Design Guide. Electrical. Metering and Monitoring. Basis of Design

ELECTRICAL INSULATION TESTING OF HV EQUIPMENT UP TO 33kV

Nothing s BetterThan the Original MODAN Power Distribution Systems

METAL-CLAD AND METAL-ENCLOSED SWITCHGEAR 3.6KV~40.5KV. tgood.com. Energy. Fast.

Series 8146/5-V37 and Series 8150/5-V37

SPECIFICATIONS FOR 220KV CAPACITOR VOLTAGE TRANSFORMER. The equipment is required for 220KV system. The system data is given as under:

Medium Voltage Products. ZN1 12 kv arc-proof air-insulated switchgear for primary distribution

Primary and Secondary Electrical Distribution Systems

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & Instructions For Installation, Operation & Maintenance

Directory chapter 04

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx

Masterclad Medium Voltage Passive Arc-Resistant Switchgear

Distributed Temperature Monitoring of Energy Transmission and Distribution Systems

Applications. Remote Display Mounting Kits

Single-Phase AC Synchronous Generator

FAQs-Main switchboard design criteria

Transcription:

Metal Clad Indoor Instrument Transformer for Plug-In Systems

RITZ Instrument Transformers GmbH Core competency Under the trading name RITZ Instrument Transformers GmbH RITZ has been pooling its activities to gather new strengths since 01/08/2007. The tradition and knowledge of the parent company RITZ Messwandler Hamburg and the subsidiary RITZ Messwandler Dresden (TuR) has been united with the companies Wandler- und Transformatoren-Werk Wirges (WTW) and Messwandlerbau Bamberg (MWB) under this name. This merger unites a total of more than two hundred years of knowhow in instrument transformers production. In addition, RITZ has decided to concentrate on the core business of medium voltage and low voltage transformers in which the high voltage division is sold. The resources gained through this shall now be applied for additional innovations and quality standards in the medium and low voltage products. RITZ is therefore securing its position on the global market. The overseas corporations of RITZ Instrument Transformers GmbH in Austria (Marchtrenk), Hungary (Kecskemét), China (Shanghai) and USA (Hartwell) strengthen the company s position on the international market. 2

Contents General Description GBEAN, GBEIN and Secondary Connections 4 Specific Advantages of Metal Clad Voltage Instrument Transformers and Plug Systems 5 Overview Cable Connections 6 Applications Plug-in Voltage Instrument Transformers Direct Connected to Switchgear 7 Plug-in Voltage Instrument Transformers with Fuse Direct Connected to Switchgear 8 Cable Connected Instrument Transformers with Fuse 8 Assembly and Fuse Information 9 Metal Clad Current Transformer with inside cone 9 Metal Clad Combined Voltage and Current Transformer 9 General Information: Test, Handling after Receipt, Maintenance, Safty Advice 10 Inquiry/Ordering Information 11 RITZ Examples of Metal Clad Instrument Transformers 11 RITZ Product Overview 12 Metal Clad Indoor Instrument Transformer 3

Indoor Voltage Transformer Type GBEAN & GBEIN 12... 52 Alternative secondary terminal connections on request General Description: Cable connecting according to DIN 57281 H07V-K1X4. The secondary leads are covered with fibre ribbons. The end splices are equipped with additional sleeves. Voltage Transformers, type GBEAN and GBEIN, are single pole insulated and casted with epoxy resin for indoor application. The resin body is covered with a grounded aluminium box. The PTs are suitable for installation in or outside of switchgears up to a highest voltage for equipment of 52 kv corresponding to all relevant international standards. The primary coil and the iron core together with the secondary winding(s) are completely resin embedded and casted in a single process step. The secondary terminals are integrated in the resin body and protected by an aluminium box. HARTING Connector. PIN assignment according to connecting diagram will be given during offer stage. Standard design drawing: AMP Connector. PIN assignment will be given during tendering phase. The cover of the aluminium box is removable and can be sealed. Each secondary terminal (M6) can be grounded separately inside of the box. The secondary terminal box is equipped with several removable cable plugs (Pg 16) according to customer request The high voltage end of the primary winding (terminal A ) can be provided with an outer or inner silicon cone and is applicable for specific plug-in or cable connection according to EN 50181. The other end of the primary winding (terminal N ) is grounded inside of the secondary terminal box [Standard design]. For other secondary design the terminal N will be grounded by the manufacturer. 4

For plug in connection the terminal A of the PT is equipped with a spring for easy and secure mounting. In case of connecting the PT to a cable elbow plug the fixing device is included in delivery. Specific Advantages of Metal Clad Voltage Instrument Transformers Available plug-in systems Cable and pluggable connection according to EN 50181 Outside cone Compact design, less space requirement Mounting outside of panel [Ring Main Unit, SF6 insulated switchgears] Safe to touch, due to grounded housing No maintenance Simple assembly Inner/outer cone according to all international standards Cable plug-in connection No cable necessary due to direct plug-in design Terminal marking according to IEC 60044-2 (Example): Type Max. rated voltage [kv] Rated current [A] A 12..24 250 B 12..36 400 C 12..36 630 Primary: Inside cone Secondary: measuring winding open delta winding a n da dn Size Max. rated voltage [kv] Rated current [A] 0 12..36 250 1 12..36 630 2 12..40,5 800 3 12..52 1250 Metal Clad Indoor Instrument Transformer 5

Overview Cable Connections Outside cone Inside cone Type A [250 A] Type B [400 A] size 0 size 1 size 2 size 3 250 A 630 A 800 A 1250 A Type C [630 A] 6

Application Plug-in Voltage Instrument Transformers - Direct Connected to Switchgear Um 12..24 kv Plug type A [250 A] Um 12..36 kv Plug size 0 [250 A] SF 6 -insulated switchgear SF 6 -insulated switchgear Silicon adapter (included in delivery) Silicon adapter (included in delivery) Um 12..36 kv Plug type B [400 A] Um 12..40,5 kv Plug size 2 [800 A] Example of T-connection option Um 12..52 kv Plug size 3 [1250 A] Metal Clad Indoor Instrument Transformer 7

Plug-in Voltage Instrument Transformers with Fuse - Direct Connected to Switchgear Um 12..36 kv size 1 [630 A], Um 12..40,5 kv size 2 [800 A] Um 12..36 kv size 1 [630 A], Um 12..40,5 kv size 2 [800 A] Fuse I N = 2 A [non accessible] Fuse I N = 2 A [accessible] Dummy cable connector Fuse I N = 2 A [non accessible] Silicon adapter included Fuse I N = 2 A [accessible] Dummy cable connector Cable Connected Instrument Transformers with Fuse Um 12..36 kv size 1 [630 A], Um 12..40,5 kv size 2 [800 A] Um 12..36 kv Plug type A [250 A], type B [400 A], type C [630 A] Fuse I N = 2 A [accessible] Dummy cable connector Fuse I N = 2 A [accessible] Dummy cable connector Um 12..36 kv size 1 [630 A], Um 12..40,5 kv size 2 [800 A] Um 12..36 kv Plug type A [250 A], type B [400 A], type C [630 A] Fuse I N = 2 A [non accessible] Fuse I N = 2 A [non accessible] 8

Assembly The PTs can be mounted either in vertical or horizontal position. Before mounting the cone has to be cleaned with cleaning benzene and coated with silicone grease. For further details please refer to the Ritz assembly manual. The dimensions of the PTs are mentioned in the outline drawing. Note: During assembly it must be strictly adhered that the PT is mounted into the connecting part in a straight and horizontal position. The plug must not be canted or twisted in any direction Fuse The PTs can be equipped with an accessible or non accessible fuse which is designed for a tripping current of 2 A. Attention: In case of tripping of the fuse a complete replacement of the PT is compulsory. The fuse does not protect the PT itself. In case of a fault it has to be assumed that the PT is partially damaged. Attention: Do not remove dummy plug, before switching off voltage. Danger! High Voltage! Metal Clad CT Inside Cone Technical data and design parameters on request Metal Clad combined PT & CT Outside Cone Metal Clad combined PT & CT Inside Cone Technical data and design parameters on request Technical data and design parameters on request Metal Clad Indoor Instrument Transformer 9

General Information Tests: A routine test according to the valid international standards for Instrument Transformers will be performed on all PTs. The results will be recorded in the test report. Handling after receipt The PTs are suitably packed for transportation. Immediately after receipt, the package should be inspected for possible transport damages. In case of any external damage or any sign of rough handling, notify Ritz Instrument Transformers GmbH immediately Safety advice Hazardous voltage is present in this electrical equipment during operation. Non-observance of the instructions can result in property damage, severe personal injury or even death. Only qualified personal should work on or around this equipment after becoming thoroughly familiar with warnings and safety notices. The successful and safe operation of this equipment depends on proper handling, installation, operation and maintenance. Maintenance No special maintenance is required. However, it is recommended to clean the surface from time to time with a dry, soft cloth. Attention: For cleaning never spray with water. Do not short circuit secondary windings. The neutral terminal N has to be grounded at any time. 10

Inquiry/Ordering Information Technical parameters Ratio Number of secondary windings Burden Accuracy class Rated voltage factor Frequency Standard Design Parameters Outer/Inner cone Plug-in or cable connection Size of plug Fuse [accessible or non-accessible] If you need some further assistance please contact our agent or one of the Ritz companies Examples of Metal Clad Instrument Transformers Voltage Transformer GBEIN12-0 Inner cone Voltage Transformer GBEAN24-0 Outer cone Voltage Transformer GBEI36 Inner cone Voltage Transformer TGBZI24 Inner cone Voltage Transformer GBEI36SES Inner cone Voltage Transformer TGBZI36 Inner cone Current Transformer GBW Inner cone Current and Voltage Transformer KGBEA Outer cone Metal Clad Indoor Instrument Transformer 11

RITZ Product Overview Medium Voltage Instrument Transformers up to 72,5 kv Indoor and Outdoor Metal Clad Design Metalized Design Burst Proofed Metering Voltage Transformers for Railway Vehicle Sensor Types Low Voltage Instrument Transformers up to 1,2 kv Current Transformers for Measuring and Protection Purposes Wound primary CT Auxiliary CT Summation CT Window type CT CT for switch fuses Tube type CT Window type CT for high currents Multi-range CT Split-core types for earth fault protection Split-core CT Special Instrument Transformers for Measuring Purposes 3-phase CT Laboratory Current and Voltage Transformers Voltage Transformers Instrument Transformers for Bill / Tariff Metering Damping Inductance Devices against Ferroresonance SIS Cast Resin Bus Bar Systems up to 72,5 kv & 7000 A The Alternative to Parallel-Connected Cables System Specific Benefits Compact design Reduced requirements for the installation space Small bending radii 3-dimensional geometric shape is possible Natural cooling due to effectual conductor design High opererational reliability due to factory routine test of each bus bar No maintenance Safety Benefits Touch Safe Fully insulated and capacitive graded system High thermal and dynamic short circuit current withstand capabilities Excluded phase to phase short-circuits No toxic fumes in case of fire - self extinguishing Cast Resin Power Transformers up to 40,5 kv and 25 MVA Applications Power Distribution Rectifier Drives Oil Platforms / Vessels Generator Excitation Injection Systems Transmitter Systems Grounding Systems Laboratory Systems Traction Power Systems (Streetcar, Tram, Metro, Railway) Electronic Instrument Transformers and Sensor Voltage-Sensoric Current-Sensoric Voltage up to 90 kv Current up to 24000 A Accuracy of 0,2 % Accuracy of 0,01 % Frequency from 0 to 10 khz Frequency from 0 to 10 khz Applications Power Engineering Grid Analyse Traction Power Distribution Systems Protection Technology Elektro-chemistry Switchgear Systems Environment Engineering Automobile Industry Research Customised Cast Resin Parts Development and formulation of cast resin moulding materials for electrical applications in low and medium voltage ranges and for electronics. Design and production of cast resin mouldings e.g. special bushings, fuse housings etc. Instrument Transformers GmbH Mühlberg 1 97514 Oberaurach-Kirchaich GERMANY Tel.: +49 95 49 89-0 Fax: +49 95 49 89-11 E-Mail: info@ritz-international.com MCGBE_en_Rev2012-12 JSW