Siemens Industry Online Support

Similar documents
The compact single-axis servo drive for basic positioning with integrated safety functions usa.siemens.com/sinamics-s110

Siemens AG 2011 SINAMICS V60. The perfect solution for basic servo applications. Brochure May 2011 SINAMICS. Answers for industry.

Simple and cost-effective positioning. SINAMICS S110 single-axis drive. SINAMICS drives. Answers for industry.

SINAMICS S120. Encoder system connection M 3 ~ Encoder system connection. 2/178 Siemens D

FAQ about Drive Technology

ABB i-bus EIB Logic Module LM/S 1.1

DNP Points List and Implementation

APPENDIX. SureSERVO QUICK START GUIDE. In This Appendix... Quick Start for SureServo Drives...A 2. Tuning Quick Start for SureServo Drives...

Jena er Antriebstechnik. GmbH. 1. Introduction. 2. Properties. 3. Hardware. 4. Baud Rates. Brief Instructions - CANopen Interface

Cover. SEB SIMOTION Easy Basics. Collection of standardized SIMOTION basic functions. FAQ April Service & Support. Answers for industry.

Motors. 13/16 Siemens PM

Technical data. General specifications. Signal voltage V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.

Commercial web offset

TwinCAT NC Configuration

WINDOW's Programming Software USER MANUAL

S and STEP 7 Basic V10.5

Applications & Tools. Configuration of Messages and Alarms in WinCC (TIA Portal) WinCC (TIA Portal) Application description December 2012

Product Information. Gateway For Connecting EnDat Encoders to PROFIBUS-DP

WIND Power Technology: IMD Integrated Motor Drive

SIMATIC. ET 200S distributed I/O 2AO I ST analog electronic module (6ES7135-4GB01-0AB0) Preface. Properties 1. Parameters 2.

For support on the Beijer HMI please contact:

Getting Started - SINAMICS Startdrive. Startdrive. SINAMICS Getting Started - SINAMICS Startdrive. Introduction 1

Technical Manual. FAN COIL CONTROLLER COOLING or HEATING ANALOG or PWM Art A

SIMATIC. S7 300 PLC CPU 317T-2 DP: Controlling a virtual axis. Introduction. Preparation. Learning units 3. Further information 4.

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

ISO Dialects for SINUMERIK

2011, The McGraw-Hill Companies, Inc. Chapter 3

Profibus Mapping of S120 Basic Speed FB115

SINAMICS drives SINAMICS DCM. DC converters from 6 kw to 2500 kw for variable-speed direct-current drives. Load-balanced control application

Quick installation guide for the Vista Quantum QNVR Network Video Recorder

SIMATIC Safety Workshop

User manual. magnetic absolute positioning drive AG03/1

Training Document for Comprehensive Automation Solutions Totally Integrated Automation (T I A) MODULE A5 Programming the CPU 314C-2DP

MEMOBUS/Modbus Communications

ABSOLUTE ROTARY ENCODER ETHERNET/IP

Cut down your costs, increase your productions efficiently with the knowledge of PLC s Siemens technology. SITRAIN TM THAILAND Page 1 of 14

2.6. In-Laboratory Session QICii Modelling Module. Modelling Module Description

Adaptive Cruise Control of a Passenger Car Using Hybrid of Sliding Mode Control and Fuzzy Logic Control

POSITIONING AND CONTOURING APCI-8001, APCI-8008 AND CPCI-8004 OPERATING MANUAL / OM CONTROL SYSTEM. Rev. 12/

Softstarters. Type PSTX Fieldbus communication, Built-in Modbus RTU. 1SFC132089M0201 April SFC132089M0201 1

Functional enhancements, rectified functional restrictions and functional restrictions, L-Force Engineer V2.20.1

Analog Servo Drive 25A8

Presentation, Drive Manager for SIMATIC Presentation

ENTBUS PLUS SOFTWARE FOR ENERGY MONITORING AND RECORDING INSTALLATION AND OPERATING MANUAL

Programming Logic controllers

ACS 800. Supplement Traverse Control Application Program 7.x

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

ABB Drives. User s Manual HTL Encoder Interface FEN-31

TIA Portal Workshop. SIMATIC Controller. Intern / Siemens AG Alle Rechte vorbehalten. Automation Days 2015 Controller Team

Digital Clamp Axis Control for Hydraulic Molding Machines

CAN & LIN Development Tool CLDT1004 HS CAN

TwinCAT The Windows Control and Automation Technology NC PTP. Numerical Control Point To Point

EnDat 2.2 Bidirectional Interface for Position Encoders

Transmitter Interface Program

Documentation for. KL2602 and KL2622. Two-channel Relay Output Terminals for 230 V AC / 30 V DC. Version: 1.4 Date:

SIMATIC. ET 200S distributed I/O 2AI U ST analog electronic module (6ES7134-4FB01-0AB0) Preface. Properties 1. Parameters 2.

EXPERIMENT 2 TRAFFIC LIGHT CONTROL SYSTEM FOR AN INTERSECTION USING S7-300 PLC

ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01

Application Note AN-SERV-006

Push button 2, 3, 5gang with room thermostat (RTR) and display flush-mounted xx, xx, xx

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

S7 for Windows S7-300/400

How To Use An American Zw.Com V20-20 (V20) V20 (Veu) V2.20 (Femalese) V1.2.2 (V2.1) V3.

Setting up the DeskCNC controller.

Drive Technology \ Drive Automation \ System Integration \ Services. Manual. MOVITRAC B Simple Positioning Application Module

13-1. This chapter explains how to use different objects.

Supplement to the Operating Instructions for SIMOREG DC-MASTER Series 6RA70. for Software Release 3.2. Version 13 Order no.

Parameter list

Brake module AX5021. Documentation. Please read this document carefully before installing and commissioning the brake module!

WinCC. Configuration Manual. Manual Volume 2

Expat kiss_fft gsoap smartgwt Linux Qt md5 zlig log 4cpp sqlite gcc/g++/libc/libc++ gwt

TL-Series Sub-Spindle Operator s Addendum

Industrial Requirements for a Converged Network

DS Wire Digital Thermometer and Thermostat

STEP 7 MICRO/WIN TUTORIAL. Step-1: How to open Step 7 Micro/WIN

DRO Function guide: Zero setting 1/2 calculation mm/inch conversion INC/ABS conversion

ABB i-bus EIB / KNX Weather Station WS/S 4.1

Nemo 96HD/HD+ MODBUS

Vodafone PC SMS (Software version 4.7.1) User Manual

Technical Information POWER PLANT CONTROLLER

PLUTO Safety-PLC. Manual Absolute Encoders

Configuring PROFINET

PIEZOMETER AIRFLOW MEASURING RING

EXTERNAL DIMENSIONS AND PARTS

Controllable Space Phaser. User Manual

Release Notes OPC-Server V3 Alarm Event for High Availability

XCal-View user manual

CCNA R&S: Introduction to Networks. Chapter 5: Ethernet

Using the STC firmware

GAM900/GAM900S. Acceleration precisely measured and safely monitored

ABB i-bus EIB / KNX Analogue Input AE/S 4.2

B Robo Claw 2 Channel 5A Motor Controller Data Sheet

Permissible ambient temperature Operation Storage, transport

SIMATIC. SM 335 High-Speed Analog Input/Output Module for the SIMATIC S7-300

Data Link Layer(1) Principal service: Transferring data from the network layer of the source machine to the one of the destination machine

Temperature Transmitter TTX300

How many high-speed counters (HSCs) are provided by the SIMATIC S PLC? SIMATIC S FAQ March Service & Support. Answers for industry.

Operating and installation instructions. Professional plasma torch height control. Model: MyPlasm THC

Transcription:

New features/modifications for SINUMERIK Safety Integrated software version 4.5 SINUMERIK 840D sl 01/2015 Siemens Industry Online Support Answers for industry.

Table of contents 1 Software version 4.5 SP2... 3 1.1 Filtering n< n x... 3 1.2 Brake test for short travel distances... 4 1.3 Additional status signal NCK Ł PLC "Axis is SI-axis"... 4 1.4 Set velocity limit selection... 5 1.5 Extension to alarm no. 27033... 5 1.6 Alarm no. 27038... 6 1.7 Alarm no. 27111... 7 1.8 Alarm no. 27112... 7 2 Software version 4.5 SP3... 9 2.1 Braking behavior for Stop B/C... 9 3 Software version 4.5 SP4... 10 3.1 Reaction in case of an encoder error during 1-Encoder Safety... 10 Page 2

1 Software version 4.5 SP2 1.1 Filtering n< n x Filtering is realized using a PT1 filter with the filter time from for SINUMERIK 840D sl: MD 36945 $MA_SAFE_VELO_X_FILTER_TIME for SINAMICS S120: p9545 SI Motion SSM (SGA n < n x ) filter time (Control Unit) and is also performed in the two monitoring channels, NCK and drive. If filtering is not necessary due to low system vibration levels or is impractical, it can be deactivated by setting MD $MA_SAFE_VELO_X_FILTER_TIME to the value 0. MD $MA_SAFE_VELO_X_FILTER_TIME and the smoothed actual velocity value with the tolerance from MD $MA_SAFE_VELO_X_HYSTERESIS are subject to crosswise data comparison. The smoothed, safe actual value of the NCK is also available in the servo trace. -------------------------------------------------------------------------------------------------------------- Note By parameterizing a filter time not equal to 0, the reaction time of the SGA n<n x increases according to the behavior of a PT1 filter. The maximum time delay of the SGA n<n x for a linear velocity increase/decrease corresponds to the filter time parameterized in MD 36945. Example: Filter time = 20 ms => The parameterized n x limit is reached with a max. delay of 20 ms. Accordingly the SGA n<nx is also set to delay. The maximum time delay of the SGA n<n x for an erratic velocity increase/decrease corresponds to three times the filter time parameterized in MD 36945. Example: Filter time = 20 ms => The parameterized n x limit is reached with a max. delay of 60 ms. Accordingly the SGA n<n x is also set to delay. -------------------------------------------------------------------------------------------------------------- Page 3

1.2 Brake test for short travel distances By setting MD $MA_SAFEBRAKETEST_CONTROL Bit 1 time monitoring and endof-record monitoring are shut down when waiting for the outline limit and actual limit to be reached. The PLC can thereby determine the waiting time itself using the TV_FXSreached timer (deselection with VDI signal = 0) Machine data MD 36968: $MA_SAFE_BRAKETEST_CONTROL Description Bit 0 = 0: The MD 1192/p1532 drive is used as the average value of the torque limit. Bit 0 = 1: The measured torque at the instant in time that the brake test is selected is used as the average value of the torque limit. Bit 1 = 0: The torque limit value must be reached during the programed travel distance. Bit 1 = 1: The torque limit value must be reached during the programed time (TV_FXSreached parameterization FB11). 1.3 Additional status signal NCK Ł PLC "Axis is SI-axis" The following status signal is newly introduced in the axial PLC user interface: DB3x.DBX70.4 "NCK Safety Integrated active" Byte Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 DBB 70 NCK Safety Integrated active Page 4

1.4 Set velocity limit selection MD 36933: SAFE_DES_VELO_LIMIT has been expanded to 4 values. The selection of one of these values is performed via the axial PLC user interface DB3x.DBX34.0...1. Meaning of this interface: Bit 0: "Setpoint limitation Bit 0" Bit 1: "Setpoint limitation Bit 1" Bit 0 Bit 1 Active setpoint limitation factor = 0 = 0 SAFE_DES_VELO_LIMIT[0] = 0 = 1 SAFE_DES_VELO_LIMIT[1] = 1 = 0 SAFE_DES_VELO_LIMIT[2] = 1 = 1 SAFE_DES_VELO_LIMIT[3] 1.5 Extension to alarm no. 27033 Axis %1 parameterization of the MD %2[%3] not valid Because of the extensions of the n<n x function to filtering and hysteresis, the alarm notes are also expanded. Parameters Note %1 = axis number %2 = machine data identifier %3 = machine data index The parameterization of machine data %2 is incorrect. An additional indication is the field index of the machine data. If the machine data is a single item of machine data, a zero is specified as a field index. This alarm occurs in the following contexts: The velocity tolerance n<nx in $MA_SAFE_VELO_X_HYSTERESIS is smaller than the slip tolerance in $MA_SAFE_SLIP_VELO_TOL. An axial SGE/SGA addresses the SPL interface outside the scope enabled via the corresponding option. The total encoder resolution (combination of low and fine resolution in $MA_SAFE_ENC_RESOL and $MA_SAFE_PULSE_SHIFT) is not valid or exceeds the supported actual value format. Page 5

1.6 Alarm no. 27038 Axis %1 value %2 in drive parameter %3 violates the limits of NCK MD %4 Parameters Notes %1 = axis number %2 = value in the drive parameter %3 = number of the drive parameter %4 = name of the NCK machine data Values that violate the permissible value range or internal limits for NCK machine data are supplied in a parameter from a Sinamics drive. If several drive parameters are specified, the combination of specified drive parameters is incorrect. In this case the result of the linking is displayed as a value The following causes are possible: r0469: Resolution of the absolution position for linear absolute encoder not valid or relationship between grid line and measuring step not binary. r0470: Number of valid bits of the redundant, rough position value incorrect. r0471: Number of fine resolution bits of the redundant, rough position value incorrect. r0472: Number of relevant bits of the redundant, rough position value incorrect or "0". r0470/0471/0472: Slide factor for rough-position bits in finely resolved actual value yields prohibited value (parameter values are not compatible). r0473: Number of safety-related measuring steps in position value POS1 not valid. r0474: A bit not recognized by the NCK is set. The alarm output in this position can be hidden using the MD $MN_SAFE_DIAGNOSIS_MASK, bit 3 = 1. r0475: Number of the highest-value bit of the redundant coarse-grained layer incorrect. r0979: Error in encoder format in acc. with PROFIdrive r9527: Encoder type not valid Page 6

1.7 Alarm no. 27111 Axis %1 encoder evaluation error of the safe actual value Remedy For DRIVE-CLiQ encoders additional check of NCK-MDs $MA_SAFE_ENC_NUM_BITS and $MA_SAFE_ENC_CONF and drive parameter r047x For DRIVECLiQ linear encoders additional check of NCK-MDs $MA_SAFE_ENC_MEAS_STEPS_RESOL and $MA_SAFE_ENC_MEAS_STEPS_POS and the drive parameter r0469 / r0473 1.8 Alarm no. 27112 Axis %1 CRC error of the safe actual value Note When checking the data consistency of the safe actual value (CRC), an error was detected. Possible causes for the alarm being permanently present: The NCK monitoring channel for safe motion monitoring does not communicate with the monitoring channel of the assigned drive, but that of another axis. Error in the encoder parameterization Incorrect encoder evaluation type Remedy Check assignment of the drive via HW Config, $MA_SAFE_CTRLOUT_MODULE_NR, $MN_SAFE_DRIVE_LOGIC_ ADDRESS and p0978 for correctness. Check the encoder mounting Check the encoder parameterization Check the NCK_MD ($MA_SAFE_ENC_IS_LINEAR, $MA_SAFE_ENC_GRID_POINT_DIST, $MA_SAFE_ENC_RESOL) and the drive parameter field r0979 For DRIVE-CLiQ encoders: Check the NCK-MDs ($MA_SAFE_ENC_NUM_BITS, $MA_SAFE_ENC_CONF) and drive parameter r047x Page 7

For DRIVE-CLiQ linear encoders additional check of NCK- MD $MA_SAFE_ENC_MEAS_STEPS_RESOL and $MA_SAFE_ENC_MEAS_STEPS_POS and the drive parameter r0469 / r0473 Check whether the encoder evaluation was replaced (SMI, SMC, SME) Check whether the encoder evaluation type was exchanged (SMx, DRIVE-CLiQ encoder) Check the encoder ID in the MD $MA_SAFE_ENC_IDENT Replace the hardware Check compliance with the EMC Directive Page 8

Software version 4.5 SP3 2 Software version 4.5 SP3 2.1 Braking behavior for Stop B/C To support gentle braking behavior for STOP B/C, the braking operation can be initiated completely independently of the drive. The velocity setpoint for a ramp defined by parameter p1135 is thereby guided to zero (AUS3 ramp). In terms of the NCK the velocity setpoint is no longer affected. This behavior can be selected via the machine data 36904 $MA_SAFE_ADD_FUNCTION_MASK, Bit 0 = 1. Activation of the AUS3 ramp takes place via the drive monitoring channel. On activation of STOP B/C in this monitoring channel the AUS3 function is also activated. If there is a time offset between activation of the STOP B/C in the NCK and drive monitoring channel, the velocity setpoint for this time difference remains unchanged. By replacing the stop reactions between NCK and drive monitoring channels the maximum time amounts to one monitoring cycle. The machine data M$MA_SAFE_ADD_FUNCTION_MASK, Bit 0 is included in the axial checksum $MA_SAFE_ACT_CHECKSUM[0]. A change to this MD becomes active after POWER ON. Page 9

Software version 4.5 SP4 3 Software version 4.5 SP4 3.1 Reaction in case of an encoder error during 1-Encoder Safety With the SINUMERIK SW version 4.5 SP4 (SINAMICS SW version 4.5 HF 25) it is possible to parameterize the reaction for an encoder error during 1-Encoder Safety via the safety encoder parameter p9516 (SI Motion encoder configuration safe functions (Control Unit)/SI Mtn Geb_kfg CU). p9516; Bit 4 = 0 Ł immediate Stop A for encoder errors p9516; Bit 4 = 1 Ł The brake is applied with a Stop F Ł B Ł A The requirement for braking with a Stop F Ł B Ł A, is that the SINAMICS parameter p9560 and the SINUMERIK machine data 36960 are set to 0. Otherwise the actual value frozen by the encoder error can simulate downtime and therefore cause a premature switch from Stop B to Stop A. Braking during an encoder error takes place via the automatic switchover to encoderless operation. Requirement here is for encoderless operation to be put into operation for the corresponding drive. The default p9516 Bit 4 setting is "0". Page 10