Probes for Coordinate Measuring Machines



Similar documents
OPTICAL MEASURING MACHINES

2003/04 price list for CMM products for Czech (in Kč)

VICKERS HARDNESS TESTER. HBS HBW Kc

Be careful not to scratch or hit front edge of the side viewing micro prisms onto hard objects!

CONTRACER CV-3100/4100 Series

MT-30 & MT-90 Series. Advanced Academic Microscopes/ Advanced Academic Polarizing Microscope INSTRUCTION MANUAL

Product catalog Issue 18

User Guide LUXXOR VIDEO MICROSCOPE. 2 Luxxor Video Microscope Set Up

Profile Projector PH-3500

LBS-300 Beam Sampler for C-mount Cameras. YAG Focal Spot Analysis Adapter. User Notes

PORTABLE MICROSCOPES PORTABLE MICROSCOPES PORTABLE MICROSCOPES PORTABLE MICROSCOPES PORTABLE MICROSCOPES PORTABLE MICROSCOPES

CALIBRATING YOUR SYSTEM. Follow our guidelines carefully to ensure proper system function. EQUIPMENT

Care and Use of the Compound Microscope

A new advance in routine inspections INVERTED MICROSCOPE CKX41/CKX31

Protocol for Microscope Calibration

SECURITY CAMERA INSTRUCTION MANUAL ENGLISH VERSION 1.0 LBC

Handheld USB Digital Endoscope/Microscope

DMS 680. Universal length measuring system gauge inspection for»iso 9000«requirements

ENGINEERING METROLOGY

Installation and use of Millett Tactical TRS-1 and TRS-2 scopes TRS-1 TRS-2. Before starting, make sure firearm is UNLOADED!!

Infrared Viewers. Manual

Product Information. QUADRA-CHEK 3000 Evaluation Electronics For Metrological Applications

ABB Robotics, June IRB 1200 Overview. ABB Group August 21, 2014 Slide 1

RL HW / RL HW+ / RL HGW / RL HV / RL HVPW/RL HVPW-G

Smart Cam, CC-Smart-Cam, and Smart Cam Packages Installation and Quick Start Operating Instructions

Atomic Force Microscope

TS-E24mm f/3.5l TS-E45mm f/2.8 TS-E90mm f/2.8 Instructions

AF 70~300 mm F/4-5.6 Di LD Macro 1:2 (Model A17)

Laserlyte-Flex Alignment System

Linear modules Lifting units Rotary modules Grip modules Inductive proximity switches Plug connectors

Length, Finland, MIKES (VTT Technical Research Centre of Finland Ltd, Centre for Metrology / Mittatekniikan keskus)

3-Component Measuring System

Tube Control Measurement, Sorting Modular System for Glass Tube

Firearms & Tool Marks Comparison Microscope. Discovery. Leeds Forensic Systems. Your Forensic Imaging Source

Reaction Torque Sensor

9.7" Microscope Tablet Camera (REALPAD 5.5) Introduction. Feature

Ektalite Slide Projectors

Features: Mounting the Optic

Melting Point. Electrothermal PRODUCT SPECIFICATIONS OPERATION

VERZUS 750CCD Universal Hardness Tester

Easy Machining Center Setup

MICROSCOPY. To demonstrate skill in the proper utilization of a light microscope.

CutMaster Major External Replacement Parts

ALTERA. Coordinate Measuring Machines. nikon metrology I vision beyond precision

DUGARD. Machine Tools Since Dugard 700L Series Heavy Duty CNC Lathes.

VISM Evolution Scope Series

CALIBRATION FOR LAL20X & LAL24X

DUGARD. Machine Tools Since Dugard 400 Slant Bed High Precision CNC Lathe.

VISM CQB Scope Series

National Optical & Scientific Instrument Inc Landmark 35 Drive San Antonio, Texas Phone (210) Fax (210)

SP AF 90mm F/2.8 Di Macro 1:1 (Model 272E)

CYMAQ Marking System AS200 + DS7050 N-14

CS Digital Microscope User Manual

The Kaps SOM -Series. Stereo Examination Microscopes for ENT Specialists. The variable space-saving system for every ENT practice

Automotive Applications of 3D Laser Scanning Introduction

TAGARNO AS Sandøvej Horsens Denmark Tel: Mail: mail@tagarno.com

KS-70. Catheterization Table GENERAL

CMM Software Page 591. Manual CMMs Page 595. Small- and Medium Size CMMs Page 596. Large Size CMMs Page 600. In-Line and Shopfloor CMMs Page 604

Day / Night IR Color Camera User Manual V2.1.0

National Optical & Scientific Instruments Inc Landmark 35 Drive San Antonio, Texas Phone (210) Fax (210)

Detachable DIY Door Viewer Camera for Home / Office Safety. Installation Manual. (* This is a patented product, do not copy) IA Technologies Inc.

PRODUCT NO.: PT-P1SD PRODUCT NAME: Digital SD Slide Projector

3D SCANNING SOLUTION FOR PIPELINE INTEGRIT Y ASSESSMENT!

microscope OP-Dent-5

Making Better Medical Devices with Multisensor Metrology

KIRÁLY TRADING KFT H-1151 Budapest Mogyoród útja tel: Clamps Clamping devices

ABERLINK 3D MKIII MEASUREMENT SOFTWARE

MAVO-MONITOR / MAVO-SPOT Instrument Set for Contact or Distant Measurements of Luminances

Tool Holder Catalog INDEX ABC VDI 25 LL /Rö

Remote Head REMO ONE. Code Manual

18-270mm F/ Di II VC PZD for Canon, Nikon (Model B008) mm F/ Di II PZD for Sony (Model B008)

Original Assembly Guide

QUICK SCOPE. Non-Contact Vision Measuring Machine Offers High Accuracy, Real Affordability and Powerful Functionality! Bulletin No.

National Optical & Scientific Instruments Inc Landmark 35 Drive San Antonio, Texas Phone (210) Fax (210)

APPLICATION NOTE. Basler racer Migration Guide. Mechanics. Flexible Mount Concept. Housing

Innovative measurement technology for real professionals.

SP AF 300mm F/2.8 LD [IF] for Canon (Model 360EE)

Subminiature Load Cell Model 8417

Torque Transducers MEASURING ELECTRONIC

Mini InfraRed Thermometer with Laser Pointer

CutMaster Major External Replacement Parts

ST-80 MICROSCOPE With Electronic Eyepiece #6810. User Guide

SITEMA PowerStroke. Technical Information TI-P11. 1 Function. 2 Applications. Mould Closing Devices series FSK. Contents

MRC High Resolution. MR-compatible digital HD video camera. User manual

SP AF 17~50 mm F/2.8 XR Di-II LD Aspherical [IF] (Model A16)

Dome Camera with IR Night Vision

2013 Wireless Video Intercom INSTALLATION GUIDE

Standard Cables (Without electromagnetic brake, with electromagnetic brake) CC010ES-2. 1 m CC020ES-2. 2 m CC030ES-2. 3 m CC050ES-2.

SJ-201P/M PORTABLE SURFACE ROUGHNESS TESTER

Rotary actuators Rotary wing drives Series RAK. Brochure

Video surveillance camera Installation Guide

Operation Manual For NDJ-8S Digital Rotary Viscometer

TRIMBLE TX5 3D LASER SCANNER QUICK START GUIDE

4.3-inch Back-Up Camera

SSC-T800series. New type with radial cross ray method. Light Curtain Sensors. Type. Radial Cross Ray Method. Detecting width. Light axis interval

EF-S18-55mm f/ IS II COPY ENG. Instruction

Directory chapter 02 - DIN Power (to 6 A) Types D, E, F, FM, 2F, F9, interface connectors I/U Technical characteristics types D and E

ELECTRIC FIELD LINES AND EQUIPOTENTIAL SURFACES

Pipeline External Corrosion Analysis Using a 3D Laser Scanner

High Resolution Media Display - B series 20mm Pitch Outdoor RGB Module

Transcription:

Coordinate Measuring Machines Probes for Coordinate Measuring Machines Bulletin No. 99

MPP-00Q/MPP-00 Ultra High-Accuracy Scanning The MPP-00Q/00 is a multi-functional probe designed for CNC coordinate measuring machines. It can not only perform a continuous path contact-type scanning measurement [a measurement method that implements a collection of a large amount of coordinate data while traveling along the path in contact with the workpiece] at V 0.μm ( ireference value when the LEGEX series is installed ), but also high-accuracy point measurement ( σ 0.μm: when the LEGEX series is installed, and data collection from a centering point measurement (shown below). The MPP-00Q/00 has internally incorporated high-accuracy scales with a minimum resolution of 0.0μm for each direction (X, Y, and axes), which makes it possible to read the stylus displacement in any direction. The air bearing employed in the sliding section of each axis helps enable this probe with minimum directionality. The ordinary touch trigger probe, even if it has only a small force to generate a trigger signal the moment the stylus actually comes into contact with the workpiece, may be subject to several tens to several hundred grams of force at the press-in that immediately follows contact. In addition, some of the scanning probes from other manufacturers employ such a structure that the motor drive mechanism forcibly specifies the probing position in order to permit the use of a longer stylus, necessitating the probe to actually have a greater measuring force. In contrast, the MPP-00Q/00 can reduce its measuring force Centering point measurement to a minimum of 0.0N so that it can even measure elastic workpieces such as resins, etc., without damaging them at all. For a scanning measurement, either of the following scanning methods can be selected: one in which scanning progresses while automatically following an unknown geometry (unknown geometry scanning), or one in which scanning progresses based on the locus of the probe tip given beforehand (known geometry scanning). With known geometry scanning it is possible to perform fast scanning at 0 mm/s. Conventionally, it is normal to evaluate geometries such as a line or a circle through point measurement. However, for evaluating the flatness or roundness of an extra precisionmachined workpiece, it is better to improve the reliability of the measurement result by evaluating the object at more measurement points. Unfortunately, it takes an extended amount of time for a touch-trigger probe to measure an object point by point. The MPP-00Q/00 can, for example, complete its measurement in several seconds even if it is required to measure inside diameters of ø00 mm at 000 measurement points. In addition, measurement can be pursued effectively while changing the scanning speed, depending on the measurement accuracy required. A wide variety of optional units, including rotary table MRT0 for synchronized scanning and the automatic stylus change system, are provided. MPP-00Q/MPP-00 Specifications MPP-00Q/ MPP-00 Automatic stylus change system (optional) Measurement range Resolution Max. permissible probing error Max. permissible probing error during scanning Spring rate Max. stylus length Max. stylus mass Stylus mount Max. tracing speed Air flow rate Probe head Applicable models No. of mountable stylus modules ±mm 0.0 m MPEPʺ 0. m (LEGEX00/700/900: When the øxmm stylus is used.) MPETHPʺ. m (LEGEX00/700/900: When the øxmm stylus is used.) 0.N/mm 00mm for both vertical and horizontal 7g M screw 0mm/s [at a known geometry scanning] 0NL/min N/A CNC CMM (LEGEX00/700/900/00 series) - standard units [Port is dedicated for the standard stylus (for calibration purpose)] - Expandable to max. 0 ports. Note, all styli should be arranged on the same axis.

MPP-00Q/MPP-00 Ultra High-Accuracy Scanning Probe 9mm ømm 0mmm mm 7.mm 0mm CLAMP X Y MPP-00 An example scanning measurement of a ring gage with the LEGEX series and MPP-00 ømm ømm Set configuration Unit Ref. No. Description Part No. Qty Mass (kg) Remark Configuration of the MPP-00 main unit No. 0AQD0 MPP-00 probe set Order No. 0ABJ79 7 9 0 MPP-00 probe main unit Damping oil Connection air hose Storage box øxmm stylus øx0mm stylus Extension L=0 mm Extension L=0 mm Extension L=00 mm MS-stylus knuckle MS-stylus center Stylus tool Allen wrench Inspection certificate MPP-00 Hardware Guide MPP-00 clamp unit configuration (of rack-mount specification) 0AQD0 0AQD090 9707 0AQD0 0 0AAD 0AAD0 0ACH7 79 H 99MCA 0AQD00A. 0.07 0.0. 0.00 0.00 0.00 0.007 0.0 0.0 0.0 0.00 0.00 0.00 0. Clamp unit.. Including one stylus mount assembly. Silicon oil (000CS) Air hose for MPP-CMM Wooden box for storing MPP-00 Standard stylus M-M ceramics M-M ceramics M-M ceramics For attaching/detaching M stylus Nominal diameter:. Hardware-only Operation Manual * Part number may vary with the main unit configuration. CLAMP X Y MPP-00 ø ruby ball 0 ø ruby ball 7 9 0 0 00 Inspection Certificate 0 Hardware Guide Stylus mount assembly Measurement range Unit : mm Detail 0 0 0 00 0 0 0 0 0 Unit Ref. No. Description Part No. Qty Mass (kg) Auto-stylus change rack Stylus mount assembly Auxiliary plate øxmm stylus MS-stylus center Reference sphere 0ABG97 0AQD0 0ABG9 0ABH7 0ABH 0.0.0 0.00 0.0 0.0 Automatic stylus change system Set Order No. 0ABG9 Remark Supplied with ports for replacement. Used for installing a rack on the CMM base. For re-calibration Unit : mm New rack 00 0 M ø0 ø0 0 Measurement range 90 70

SP0 High-accuracy scanning probe adaptive to long-type stylus The SP0 scanning probe is designed to employ a long stylus that has high measurement accuracy and a maximum length of 00 mm (measured in both the horizontal and vertical directions). It is a multi-function probe for CNC coordinate measuring machines that undertakes not only scanning measurement (a measurement method that collects a large amount of coordinate data while traveling along the path in contact with the workpiece) but also high-accuracy point measurement as well as data collection from a centering point measurement (shown below). For scanning measurement, either of the following scanning methods can be selected: one in which scanning progresses while automatically following an unknown geometry (unknown geometry scanning), or one in which scanning progresses based on the locus of the probe tip given beforehand (known geometry scanning). With known geometry scanning it is possible to perform fast scanning at 0 mm/s. Conventionally, it is normal to evaluate geometries such as a line or circle through point measurement. However, for evaluating the flatness or roundness of an extra precision-machined workpiece, it is better to improve the reliability of the measurement result by evaluating the object at more measurement points. Unfortunately, extended time is required for a touch-trigger probe to measure an object point by point. The MPP-00Q/00 can, for example, complete its measurement in several seconds, even if it is required to measure inside diameters of ø00 mm at 000 measurement points. In addition, any measurement can be pursued effectively while changing the scanning speed, depending on the measurement accuracy required. Centering point measurement A wide variety of optional units, including rotary table MRT0 for synchronized scanning and the automatic stylus change system, are provided. SP0 Specifications SP0 Measurement range Max. permissible probing error during scanning Spring rate Max. stylus length Max. stylus mass Stylus mount Max. scanning speed Probe head Applicable models ±.mm MPETHPʺ.0 m (Crysta-Apex C700/900: If the øx0mm stylus is used.).n/mm 00mm 00g M 0mm/s [at a known geometry scanning] N/A CNC coordinate measuring machines

SP0 High-accuracy scanning probe adaptive to long-type stylus mm KM0 0mm 0mm SH0 main unit mm mm SH0 mm mm x M Set configuration SP0 main unit Description Part No. Mass (kg) Remark SP0 basic set 0ABT. One SP0 main unit, SH0, KM0, and øx0mm stylus Parts for SP0 Description Part No. Mass (kg) Qty SP0 adapter SP0 Probe cable SP0 EXT cable IU 0 SP0 Power Supply BOX OPT00S-MPP OPT00 attachment Control ROM (MAIN) Control ROM (OPT) 0ABT7 0ABT 0ABT90 0ABT 0ABT9 0ABN 0AAS7 0AA0 0AA09 Mass (kg) 0. 0. 0. 0. 0. 0. 0.0 0.0.7 * Part number may vary with the main unit configuration. KM0 SP0 main unit SH0 MRS SP0 stylus change set (00mm-rail specifications) / Oder No. 0ABT7 Description Part No. Unit Mass (kg) MRS kit# SH0 SCP0 Rack plate (auxiliary plate) ACR attachment Mass (kg) 0ABT9 0ABT 0ABT 0ABG9 0ABP7. 0.. 0.0.9 SCP0 SCP0 mm SP0 stylus change set (000mm-rail specifications) / Oder No. 0ABT77 Description Part No. Unit Mass (kg) MRS kit# SH0 SCP0 Rack plate (auxiliary plate) ACR attachment Mass (kg) 0ABT0 0ABT 0ABT 0ABG9 0ABP7.7 0.. 0.0. 0mm mm

SPM Centering point measurement The SP is a compact high-accuracy scanning probe with an outside diameter of ø mm. This multi-functional probe is suitable for a CNC coordinate measuring machine that performs not only scanning measurement (measurement method that collects a large amount of coordinate data while traveling along the path in contact with the workpiece), but also high-accuracy point measurement, as well as data collection from a centering point measurement (shown below). For a scanning measurement either of the following scanning methods can be selected: one in which the scanning progresses while automatically following an unknown geometry (unknown geometry scanning), and one in which scanning progresses based on the locus of the probe tip given beforehand (known geometry scanning). With known geometry scanning it is possible to perform fast scanning at a maximum of 0 mm/s. Conventionally, it is normal to evaluate geometries such as a line or a circle through point measurement. However, for evaluating the flatness or roundness of an extra precision-machined workpiece, it is better to improve the reliability of a measurement result by evaluating the object at more measurement points. Unfortunately, an extended of time is required for a touch-trigger probe to measure such an object point by point. The SP- can, for example, complete its measurement in several seconds even if it is required to measure inside diameters of ø00 mm at 000 measurement points. In addition, it can pursue any measurement effectively while changing the scanning speed, depending on the measurement accuracy required. change of probe orientations Since the SP can be mounted on a probe head such as the PH0M/PH0MQ that automatically changes the probe orientation, it can greatly reduce the preparation time for measurement and for actual measurement in comparison to a conventional-type scanning probe whose position is fixed downward. In addition, the use of other probes, as advantaged by the probe change system, makes it possible to realize full automation in measuring various forms of machined parts. A wide variety of optional units, including rotary table MRT0 for synchronized scanning and the automatic stylus change system, are provided. SPM Specifications SPM Measurement range Max. permissible probing error during scanning Spring rate Amount of over travel Max. stylus length Stylus mount Max. scanning speed Probe head Applicable models ±0.mm MPETHPʺ. m (Crysta-Apex C700/900: If the øx0mm stylus is used.) 0.N/mm ±.0mm (XY) ±.7mm () 00mm (When SM- or SH- is used.) M 0mm/s [at a known geometry scanning] Essential: PH0M/PH0MQ CNC coordinate measuring machines

SPM.mm.mm TM-0 7.0mm SM-.mm SM- 9.mm SM- mm ømm SPM probe body TM-0 ø.mm TP0 module.9mm Stylus that can be attached: 0 to 0mm long Stylus that can be attached:.mm 0 to 7mm long (Overall stylus length between 0 to 0mm.) SH-.mm SH- Stylus that can be attached: 0 to 00mm long (Overall stylus length between 0 to 00mm. Fixed to SH-..0mm SH- ømm Fixed to SH-. Configuration Description SPM full combination kit SPM scanning kit # SPM scanning kit # SPM scanning kit # Scanning module SM- kit Scanning module SM- kit Scanning module Stylus holder SH- Stylus holder SH- Stylus holder SH- TM-0TTP module adapter kit # TTP module adapter kit TM-0 Part No. 0ABS99 0ABS970 0ABS97 0ABS97 0ABS 0ABS 0ABS 0ABS 0ABS 0ABS7 0ABS7 0ABS7 Remark A complete set of SPM, SM-//, SH-//, and TM-0 A complete set of SPM, SM-, and SH- A complete set of SPM, SM-, and SH- A complete set of SPM, SM-, and SH- A complete set of SM- and SH- A complete set of SM- and SH- A complete set of SM- and SH- A set of TP0 standard force module and TM-0 * TTP module (TM-0, TP0 module) will be supported for MCOSMOS V. or later releases. * SPM internally uses the high-power LED light source. Exercise caution when handing, in accordance with the Operation Manual. * Can be mounted on the MRS rack. 7

MPP-00 High-Accuracy Scanning Probe The MPP-00 is a low-price and high-accuracy scanning probe. It is a multi-function probe for CNC coordinate measuring machines that performs not only a scanning measurement (a measurement method that collects a large amount of coordinate data while traveling along the path in contact with the workpiece) but also a high-accuracy point measurement, as well as data collection from centering point measurement (shown below). For scanning measurement, either of the following scanning methods can be selected: one in which scanning progresses while automatically following an unknown geometry (unknown geometry scanning), and one in which scanning progresses based on the locus of the probe tip given beforehand (known geometry scanning). With known geometry scanning it is possible to perform fast scanning at 0 mm/s. Conventionally, it is normal to evaluate geometries such as a line or circle through point measurement. However, for evaluating the flatness or roundness of an extra precision-machined workpiece, it is better to improve the reliability of a measurement result by evaluating the object at more measurement points. Unfortunately, an extended amount of time is required for a touchtrigger probe to measure such the object point by point. The MPP-00 can, for example, complete its measurement in several seconds, even if it is required to measure inside diameters of ø00 mm at 000 measurement points. In addition, it can pursue any measurement effectively while changing the scanning speed, depending on the measurement accuracy required. Centering point measurement The MPP-00 has internally incorporated high-accuracy scales with a minimum resolution of 0.0μm for each direction (X, Y and axes), which makes it possible to read the stylus displacement in any direction. MPP-00 Specifications MPP-00 Automatic stylus change system (optional) Measurement range Resolution Max. permissible probing error during scanning Spring rate Max. stylus length Max. stylus mass Stylus mount Max. scanning speed Air flow rate Probe head Applicable models No. of mountable stylus modules ±mm 0. m MPETHPʺ.0 m (Crysta-Apex C series: if the øxmm stylus is used.) 0.7N/mm 00mm for both vertical and horizontal 7g M screw 0mm/s 0NL/min N/A CNC CMM (Crysta-Apex C series, Bright-STRATO series) - standard units [Port is dedicated to the standard stylus (for calibration purposes)] - Expandable to a maximum 0 ports. However, all styli should be arranged on the same axis.

MPP-00 High-Accuracy Scanning Probe ø90mm ømm 0mm mm.mm 0mm CLAMP X Y MPP-00 ømm ø9mm Set configuration Unit Ref. No. Description Part No. Qty Mass (kg) Remark MPP-00 main unit configuration No. 0AQD00 MPP-00 probe main unit Damping oil Connection air hose Storage box øxmm stylus øx0mm stylus 0AQD00 0AQD090 9707 0AQD00. 0.07 0.0. 0.00 0.00 7 Extension L=0mm 0 0.00 M-M ceramics. MPP-00 probe Extension L=0mm 0.007 M-M ceramics set Order No. 0ABG9 Clamp unit 9 0 Extension L=00mm MS-stylus knuckle MS-stylus center Stylus tool Allen wrench Inspection certificate MPP-00 Hardware Guide MPP-00 clamp unit configuration (desktop specification) 0AAD 0AAD0 0ABH7 79 H 99MCA 0AQD00A 0.0 0.0 0.0 0.00 0.00 0.00 0.. M-M ceramics Including one stylus mount assembly. Silicon oil (000CS) Air hose for MPP-CMM Wooden box for storing MPP-00 Standard stylus For attaching/detaching M stylus Nominal diameter:. Hardware-only Operation Manual * Part numbers may vary with the main unit configuration. CLAMP X Y MPP-00 ø ruby ball 0 ø ruby ball 7 9 0 0 00 Inspection Certificate 0 Hardware Guide Stylus mount assembly Unit : mm Unit : mm Detail 0 0 0 00 0 0 0 0 Measurement range 0 Unit Ref. No. Description Part No. Qty Mass (kg) Remark Automatic stylus change system Set No. 0ABG9 Auto-stylus change rack Stylus mount assembly Auxiliary plate øxmm stylus MS-stylus center Reference sphere 0ABG97 0AQD0 0ABG9 99 0ABH7 0ABH 0.0.0 0.00 0.0 0.0 Supplied with ports for replacement. Used for installing a rack on the CMM base. For re-calibration Unit : mm New rack 00 M 0 Ø0 Ø0 0 Measurement range 90 70 9

QVP The QVP probe performs form measurement by image processing micro geometry that cannot be measured by a contact type probe, or elastic bodies that are easily deformed by slight measuring forces. Although the method of microscopic measurement with the centering microscope mounted on the coordinate measuring machine has been used since coordinate measuring machines came into use in the industry, they have an inherent disadvantage in that the operation of identifying positions is dependent on the operator s eye, resulting in possible measurement errors. Even with a CNC coordinate measuring machine manual measurement must be performed sometimes, such as with an installed centering microscope. The QVP probe is an vision probe dedicated for coordinate measuring machines and was developed based on Mitutoyo s state-of-the-art technology, in order to enable full automation of image measurement with a CNC coordinate measuring machine. This technology was originally developed for Mitutoyo vision measuring machines. The QVP-captured image will have various automatic edge detections performed by the dedicated software, Visionpak, and then various calculation processes (calculation of dimensions and geometrical deviations) will be performed by the general-purpose measurement program, Geopak. Since the QVP is equipped with the standard co-axial light running through the lens system as well as white-light LED ring illumination, which is bright and has a long service life, no auxiliary illumination is required. The light volume can be set to between 0 and 00% at % increments. The QVP can also be mounted onto an automatic probe changer, allowing full-automatic measurement including both the contact and non-contact types in combination with the contact-type probes. QVP main unit Objective QVP I/F BOX CCD size Optical tube magnification Illuminating Co-axial function Ring Mass Optical magnification Observation range (mm) Working distance (mm) Magnification Numerical Aperture (N.A.) Depth of focus ( m) Mass Supply voltage Frequency Power capacity Mass 0.X 9.X. 9 X Optional 0.0 0 70g / inch (B/W) 0.X White light LED source (built-in): Power dissipation W or less White light LED source: Power dissipation 0W or less Automatic-joint type: 0g, shank type: g.x.x. 7. X Standard 0.07 7g AC00 to 0V 0/0Hz W 00g.X.9X. 9. X Optional 0. 9g X X. 0X Optional 0. 7g 0

QVP ø70 ø70 0 Objective MLX (7-0) Objective MLX (7-0) Objective ML0X (7-0) 0 ø 0 ø.99.7.7 Calibration gage (0AQC0) - Gage for sharing the coordinates between the QVP and contact-type probe 7.7 W.D.= 7. QVP-A (Automatic-joint type) QVP-S (Shank type) Calibration chart (9) - Gage for calibrating a single QVP unit Unit : mm Data processing unit Dedicated data processing software VISIONPAK VISIONPAK operates under the Microsoft Windows operating system and is a general-purpose measurement program for coordinate measuring machines. It displays the image window when it detects a workpiece edge. After detecting an edge, it undertakes various calculations with the regular general-purpose measurement programs. Wide variety of image processing functions With the powerful image processing functions (tools) it can detect various forms of edges at high speed. It can measure in the height direction by means of its auto-focus function, and save the captured image as the image data (bitmap format) as well. Outlier removal function In ordinary micro-form measurement it is often difficult to remove burrs and dusts from the objective workpiece, resulting in an inevitable measurement error. In contrast, VISIONPAK can recognize, for example, the obstruction as an "outlier" and bypass it during measurement. ocessing Tool Simple tool Manual tool Used for detecting a single point on the edge pointed to by the arrow. Box tool Used for detecting an optional position pointed to (clicked on) by the mouse. Centroid tool Used for multiple-point line measurement of an edge caught in the box Circle tool Used for detecting the center of gravity of an optional form. Edge self-tracing tool Used for multiple-point measurement of a circle for the objective circular edge. As with the box tool, it can collect data that is free from the effect of burrs and dust. By simply specifying the start point and measurement interval, the objective edge can be detected while automatically tracing an unknown geometry.

CF0 Centering Microscope for Coordinate Measuring Machines The CF0 is a centering microscope that enables measurement of small holes and elastic bodies which are difficult for a touch trigger probe to measure. With the CF0 the coordinate measuring machine can be used as a large microscope. To cope with the size and form of a workpiece to be observed and measured, lenses of various magnifications and reticles for form comparison are provided. The dedicated CCD camera can be mounted on the back of the CF0 main unit. Video signals from the camera can be displayed as an image on the external monitor. This is a great aid in relieving eye stress, especially if several hours of work must be done. ømm Eyepiece Monocular unit Objective (optional) CF0 main unit mm 0 7mm 0mm Illumination unit.mm mm CF0 monocular set (7-0) CF0 binocular set (7-0) CF0 protractor eyepiece set CF0 double image set CF0 disc plate set (7-0) (7-0) (7-0) Shank (ømm) Disc-plate eyepiece unit Binocular unit Protractor eyepiece unit Double-image eyepiece unit Monocular unit Shank (ømm) Shank (ømm) Shank (ømm) Shank (ømm) Main unit Main unit Main unit Main unit Main unit Specifications Description CF0 monocular set (7-0) CF0 binocular set (7-0) CF0 protractor eyepiece set (7-0) CF0 double image set (7-0) CF0 disc plate set (7-0) Specification Accessory CF0X eyepiece, field number Cross hair and concentric circle reticle. Illumination unit (7-07) CF0X eyepiece, field number. Spare lamp () Cross hair and concentric circle reticle (right). Lens cap Pupil distance adjustment: - 7mm CF0X eyepiece, field number. Tools Measurement range: 0, Angle index:. Power cable Minimum reading: ' (vernier scale). Operation Manual CF0X eyepiece, field number 7. Storage box CF0X eyepiece, field number ISO metric/unify screws Cross hair and concentric circle reticle/ dotted line cross scale, ML X objective Illumination unit (7-07) Power supply box Lamphouse

CF0 Centering Microscope for Coordinate Measuring Machines CF X CF X CF X ML X Unit: mm. 7.7 (working distance) 0 (parfocal distance) 0. 0. 0 ø0 ø ø ø0 ø ø ø0 ø ø0 ø 9 (working distance) 0 (parfocal distance). 77. (working distance) 0 (parfocal distance) 7. 7. (working distance) 0 (parfocal distance) ML X ML 0X CF zoom X - X ø0 ø7 ø ø ø0 ø. ø ø ø ø. ø ø7. 0. 0. 9. (working distance) 0 (parfocal distance) (working distance) 0 (parfocal distance). 0 0 (working distance) 0 (parfocal distance) Order No. 7-0 7-0 7-0 7-07 7-0 7-0 7-0 Description CF X CF X CF X ML X ML X ML 0X CF zoom X - X X X X Numerical Working distance Aperture (N.A.) W.D. (mm) 0.0 0.0 0.07 0.07 0. 0. 0.0 0. 0. 7.7 9 77. 7. 9..0 0 Resolution R ( m) 9...9.9...9.7.7 Depth of focus of single objective lens ±D.F. ( m) 0 7 7 7 7 Values for resolution and depth of focus of a single objective lens are calculated based on the reference wavelength ( =0. m). The real field of view (mm) can be obtained from Field number/objective magnification. Fiber optic circular illumination unit (7-) Twin-fiber optic illumination unit (7-) Mass (g) 0 00 00 Unit: mm ø (cross hair and concentric circle) (90º/0º dash-dot line) No. 7-0 No. 7-0 No. 7-0 No. 7-0 0º 0 (grid) der No. 0-0]. C-mount adapter (C). /-inch, 0,000-pixel color camera Monitor cable (supplied with the color monitor of, below). Camera cable, length: m. Operation Manual. Color monitor,. Controller - Vertical reference line: Move, lock -inches ( for each vertical and horizontal line) - Video output: VGA, NTSC (VBS), Y/C synchronous outputs CCTV (VGA) system Ref. No. Part No. 0AAV7 0AAV7 0AAV77 0AAV7 970 Description /-inch color camera Controller Color monitor unit Camera cable C-mount adapter (C) User's Manual Qty CCD Manufactured by SONY Length: m Common to 7-7 Remark Color TV (VGA) System No. 0AAV7, which includes the accessory set of Ref. Nos. to (common to the order No. 7-7 CCD Color TV System) Real field of view (mm) on the monitor can be obtained from CCD camera's imaging device pixels (VxH)/Objective magnification.

TP7M ( high-accuracy ) High-Accuracy Touch Trigger Probe This is a high-accuracy touch trigger probe with a maximum repeatability of σ 0.μm. change of probe orientations Since the TP7M can be mounted on a probe head, such as the PH0M/PH0MQ that automatically changes the probe orientation, it can greatly reduce the preparation time for measurement and for actual measurement in comparison to a conventional-type scanning probe with a position that is fixed downward. In addition, the use of other probes, as advantaged by the probe change system, makes it possible to realize full automation in measuring various forms of machined parts. The TP7M can mount a long stylus up to 0 mm long*. In combination with the longest extension of 00 mm equipped for the PH0M/PH0MQ, it can reach a position at a maximum distance of 0 mm. * This maximum length may vary with the coordinate measuring machine main unit being used and/or the material/diameter of the stylus itself. TP7M Specifications TP7M Measuring direction Standard stylus Repeatability ( ) Directionality (XY: D) Required force to generate trigger signal Amount of over-travel Required force to achieve over-travel Maximum stylus length Stylus mounting method Mass of a single unit Durability Probe head Applicable models XY XY XY ±X, ±Y, + øxmm 0. m or less (When the standard stylus is used.) ±0. m or less 0.0N (When the 0mm stylus is used.) 0.N (When the 0mm stylus is used.) ±º ±mm 0.9N (When the 0mm stylus is used.).9n (When the 0mm stylus is used.) 0mm M screw g 0,000,000 times Essential: PH0M/PH0MQ CNC coordinate measuring machines

TP7M ( high-accuracy ) High-Accuracy Touch Trigger Probe ømm RENISHAW mm mm 0mm ømm der No. 9] Unit : mm Unit Ref. Description No. Touch trigger probe TP7M Joint key S0 Part No. Mass(g) 9 77 Qty Remark M-stylus mount Automatic joint ø M-stylus tool M-stylus tool 79 0. 0.7 For attaching/detaching the stylus 0 7 TP7M probe stylus set No. 9 7 9 0 Stylus øx00 (M) Stylus øx0 (M) Stylus øx (M) Stylus øx9 (M) Stylus øx9. (M) Stylus ø0 ceramic (M) Stylus øx (M) Stylus ø0.x0 (M) Stylus øx0 (M) Stylus øx0 (M) Extension L00 Extension L7 9 97 99 990 99 99 7 7 09........0 0.9 0... Standard stylus M male - M female M male - M female 7 9 0 7 9 Extension L0 Extension L0 Extension L0... M male - M female M male - M female M 9 7 0 Extension L0 Extension L0 0 09.. M M 0 7 Extension L0 Extension L0 Adapter L9 Adapter L MS-stylus center MS-stylus center 0 07 0 99 77 0.9 0.. 0.. M M M male - M female M male - M female M M 9 0 ø ø 9 MS-stylus center Wooden box 00 99.0 700 M ø Extension set No. 9 0 Probe extension PEM Probe extension PEM Probe extension PEM Wooden box 99 99 997 99 90 0 00 L0 L00 L00 User's Manual 999 00

TP00 High-Accuracy Touch Trigger Probe This touch trigger probe has an outside diameter as small as ø. mm, which greatly contributes to probing complex portions of a workpiece. With the combined use of an appropriate probe extension it can probe even deeper locations. - Since the TP00 can be mounted on a probe head, such as the PH0M/PH0MQ that automatically changes the probe orientation, it can drastically reduce the time required to prepare for measurement and for actual measurement in comparison to a conventionaltype scanning probe with a position that is fixed downward. If the measurement cannot be performed by merely changing the probe orientation (such as when it is impossible to measure without replacing the normal stylus with one that has a different diameter or unique form), this automatic stylus change via the stylus change system allows full-automatic measurement to be completed without being interrupted mid-course. In addition, working with other probes, as advantaged by the probe change system, makes it possible to realize full automation in measuring various forms of machined parts. TP00 specifications TP00 SCR00 (optional) Measuring direction Repeatability ( ) Directionality (XY: D) Directionality (XY: D) Required force to generate trigger signal Amount of over-travel Required force to achieve over-travel Maximum stylus length Maximum stylus mass Stylus mounting method Mass of a single unit Durability Probe head Applicable models Note: Stylus module replacement accuracy Number of stylus modules that can be mounted XY XY XY ±X, ±Y, ± 0. m or less (with 0mm stylus), 0. m or less (with the 0mm stylus) ±0. m or less (with 0mm stylus), ±0. m or less (with the 0mm stylus) ±0. m or less (with 0mm stylus), ± m or less (with the 0mm stylus) 0.0N (STANDARD/LOW FORCE), where a 0mm stylus is used. 0.07N (STANDARD/LOW FORCE), where a 0mm stylus is used. XY±º +.mm (with 0.07N), +mm (with 0.N) 0.N (STANDARD FORCE) 0.N (LOW FORCE) N (STANDARD FORCE) N (LOW FORCE) 0mm (STANDARD FORCE) 0mm (LOW FORCE) g (STANDARD FORCE), g (LOW FORCE) M screw g 0,000,000 times Essential: PH0M/PH0MQ/MIH/PH CNC coordinate measuring machines Any stylus less than ømm should be used with the LOW FORCE module. Repeated positioning accuracy:.0 m or less (through automatic change), when a 0mm stylus is used. *.0 m or less at a manual replacement: when a 0mm stylus is used. Maximum units

TP00 High-Accuracy Touch Trigger Probe M ø.mm TP00 Probe main unit MX0. RENISHAW 0mm mm 0mm Stylus module ømm 0 Touch trigger probe TP00 set Order No. 0AAL A complete set of TP00 probe No. 0AAL Stylus set for TP00 No. 0AAL Ref. No. Description Part No. Qty Remark 7 9 0 TP00 probe Stylus module (standard) Cleaning tool Single-ended wrench Double-ended wrench Stylus tool Stylus øx0 (M) Stylus øx0 (M) Stylus øx0 (M) Extension 0mm (M) Extension 0mm (M) Carbon extension attachment tool Wooden box User's Manual Certificate 0AAL 0AAL 0AAL 0 09 0 0AAL7 0AAL 0AAL 0AAL 0AAL Standard measuring force (at over-travel) For cleaning the stylus module For attaching/detaching the probe (S) For attaching/detaching the probe (S9) For attaching/detaching the stylus (S7) Standard stylus Carbon fiber Carbon fiber Stylus storage box 0 0 7 9 Unit : mm Automatic stylus change system kit (Order No. 0AAL0) No. Description Stylus module (low measuring force) Stylus module (standard) SCR00 kit PL Part No. Qty 0AAL 0AAL 0AAL7 0AAM7 Specification (use) For ball stylus less than ø With a rack mount kit PI00-SCR00 connection cable Mass (kg) 0.0 0.0 0.9 0. 7

TP0 Touch Trigger Probe This touch trigger probe has an outside diameter as small as ø. mm, which greatly contributes to probing complex portions of a workpiece. With the combined use of an appropriate probe extension it can probe even deeper locations. - Since the TP0 can be mounted on a probe head such as the PH0M/PH0MQ that automatically changes the probe orientation, it can drastically reduce the time required to prepare for measurement and for actual measurement in comparison to a conventionaltype scanning probe that has a position fixed downward (when it is mounted on the CNC coordinate measuring machine). If the measurement cannot be achieved by simply changing the probe orientation (such as when it is not possible to make measurements without replacing the normal stylus with one having a different diameter or unique form), automatic stylus change via the stylus change system allows full-automatic measurement to be completed without mid-course interruption. In addition, the use of other probes as advantaged by the probe change system makes it possible to realize full automation in measuring various forms of machined parts (when it is mounted on the CNC coordinate measuring machine). TP0 Specifications TP0 MCR0 (optional) Measuring direction Repeatability ( ) Directionality (XY: D) Directionality (XY: D) Required force to generate trigger signal Amount of over-travel Required force to achieve over-travel Maximum stylus length XY Stylus mounting method Mass of a single unit Durability Probe head Applicable models Probe module replacement accuracy Number of stylus modules that can be mounted XY XY ±X, ±Y, + 0. m or less ±0. m or less (with the STANDARD FORCE 0mm stylus), ±. m or less (with the 0mm stylus) ± m or less (with the STANDARD FORCE 0mm stylus), ± m or less (with the 0mm stylus) 0.0N (STANDARD FORCE), with 0mm stylus 0.N (MEDIUM FORCE), with mm stylus 0.N (EXTENDED FORCE), with 0mm stylus 0.7N (STANDARD FORCE).9N (MEDIUM FORCE).N (EXTENDED FORCE) ±º +.0mm (STANDARD FORCE) +.7mm (MEDIUM FORCE) +.mm (EXTENDED FORCE) 0. to 0.N (STANDARD FORCE) 0. to 0.N (MEDIUM FORCE) 0. to 0.N (EXTENDED FORCE).N (STANDARD FORCE) 7N (MEDIUM FORCE) 0 (EXTENDED FORCE) 0mm (STANDARD FORCE) 0mm (MEDIUM FORCE) 0mm (EXTENDED FORCE) M screw g (probe body: g, probe module: 9g),000,000 times Essential: PH0M/PH0MQ/MIH/PH Manual/CNC coordinate measuring machines Repeatability positioning accuracy:.0 m or less (through automatic change), when a 0mm stylus is used. *.0 m or less at a manual replacement: when a 0mm stylus is used. Maximum units

TP0 Touch Trigger Probe M ø.mm Probe main unit 9mm Probe module MX0. mm 0mm 9mm ømm der No. 0AA Touch trigger probe TP0 set Order No. 0AAV7 Ref. No. Description Part No. Qty Mass Specification (use) 7 9 0 TP0 probe main unit Probe module [STANDARD] Probe module [MEDIUM] øx0mm stylus Cleaning tool Single-ended wrench Double-ended wrench Stylus tool User's Manual Certificate 0AAV 0AAV 0AAV 0AAL 0 99MCA00 g 9g 9g 0.g g g g g 00g g 0g Measuring force (small) Measuring force (medium) Standard stylus For cleaning stylus module For attaching/detaching probe For attaching/detaching stylus Total mass including package 7 9 0 Standard force module Medium force module Extended force module EM-STD (Standard force module with extension) EM-STD (Standard force module with extension) The extension and probe module are integrated and cannot be separated. Pr MCR0 set Order No. 0AAV.kg Accessories (standard force) 9

TP-W This touch trigger probe has an outside diameter as small as ø mm, which greatly contributes to probing complex portions of a workpiece. With the combined use of an appropriate probe extension it can probe even deeper locations. change of probe orientation Since the TP-W can be mounted on a probe head such as the PH0M/PH0MQ that automatically changes the probe orientation, it can drastically reduce the time required to prepare for measurement and for actual measurement in comparison to a conventionaltype scanning probe that has a fixed position downward. With the combined use of an appropriate probe extension it can probe even deeper locations (when it is mounted on the CNC coordinate measuring machine). TP-W Specifications TP-W Measuring direction Repeatability ( ) Directionality (XY: D) Directionality (XY: D) Required force to generate trigger signal Amount of over-travel Required force to achieve over-travel Stylus mounting method Mass of single unit Durability Probe head Applicable models XY XY XY ±X, ±Y, + 0. m or less ±0. m (with 0mm stylus), ±. m (with the 0mm stylus) ± m (with 0mm stylus), ± m (with the 0mm stylus) 0.07 to 0.N (Variable. Standard: 0.07N) 0.7N (when the X and Y axis are set to standard) XY±º, +mm (when the required force to generate trigger signal is 0.07N) ±mm (when the required force to generate trigger signal is 0.07N), +mm (at 0.N) 0. to 0.N N (when the required force to generate trigger signal is 0.07N) M screw g,000,000 times Essential: PH0M/PH0MQ/MIH/PH Manual/CNC coordinate measuring machines 0

TP-W M ømm Set configuration No. Description Part No. Qty Mass (kg) Remark TP-W PH (ø) 977A 0.0 0. 7 9 0 7 9 0 Carbon fiber extension bar Stylus Single-ended wrench Double-ended wrench MS-stylus tool Allen keys (-piece set) Storage box User's Manual Certificate Signal cable Signal cable Signal cable 0ABM 0ABM 0ABM 99 0 909 0AAN 97 979 90 for each * See the table below. * See the table below. * See the table below. 0.0 0.07 0.0 0.000 0.000 0.000 0.000 0.00 0.00 0.00 0.00 0.00. 0. 0.0 0. 0.0 0.0 L=0mm L=00mm L=00mm øx0mm standard stylus øx0mm øx0mm øx0mm Carbon fiber ball For attaching/detaching the probe For attaching/detaching the probe For attaching/detaching the stylus P-P straight, m P-P curl code P-P curl code ø ø mm mm MX0. 0 9 ø0 7 ø 0 00 ø 0 0 ø 0 00 ø ø 0 ø ø 7 9 0 ø" 0 7 Set order No. 0ABM 0ABM9 0ABM0 0ABM Configuration No. - No. - 7, 9 No. - 7, 0 No. - 7 Mass (kg).9.79.79.7 Remark With signal cable (P-P straight, m) With signal cable (P-P curl code) With signal cable (P-P curl code) Signal cable: None Unit : mm der No. 9] No. Description Part No. Qty 7 9 Touch trigger probe TP-W Stylus øx0mm Stylus øx0mm Stylus øx0mm Stylus øx0mm Stylus tool S7 Allen keys ( sizes) Storage box User's Manual 0 99 90 for each ø ø 0 7 ø 0 ø 0 0 ø 9 Unit : mm

MH0i This series of touch trigger probes has a manually operable probe head for coordinate measuring machines. The probe module part has an outside diameter as small as ø. mm, which greatly aids in probing complex portions of a workpiece. Other probe modules employing an extension either 0 mm long or 70 mm long are also provided. The probe head part of the MH0i has a structure that not only permits its position (probe orientation) to be manually changed but also provides a maximum of orientations (at a positioning repeatability σ.μm). Even for measurement of a complex threedimensional form that requires repeated changes in the probe orientation, preliminary registration of required positions can eliminate re-calibration after each positional change, thereby broadly improving the measurement efficiency. MH0i Specifications MH0i Measuring direction Position change Repeated positioning accuracy Repeatability ( ) Directionality (XY: D) Directionality (XY: D) Required force to XY generate trigger signal Amount of over-travel Required force to achieve over-travel Maximum stylus length XY XY Stylus mounting method Mass of a single probe unit Durability Probe head Applicable models ±X, ±Y, + Manually for A axis (vertical direction): 0 to 90º (at º increments), and for B axis (horizontal direction): ±0º (at º increments) ʺ. m 0. m or less ±0. m or less (with the STANDARD FORCE 0mm stylus), ±. m or less (with the 0mm stylus) ± m or less (with the STANDARD FORCE 0mm stylus), ± m or less (with the 0mm stylus) 0.0N (STANDARD FORCE), with the 0mm stylus 0.N (MEDIUM FORCE), with the mm stylus 0.N (EXTENDED FORCE), with the 0mm stylus 0.7N (STANDARD FORCE).9N (MEDIUM FORCE).N (EXTENDED FORCE) ±º +.0mm (STANDARD FORCE) +.7mm (MEDIUM FORCE) +.mm (EXTENDED FORCE) 0. - 0.N (STANDARD FORCE) 0. - 0.N (MEDIUM FORCE) 0. to 0.N (EXTENDED FORCE).N (STANDARD FORCE) 7N (MEDIUM FORCE) 0N (EXTENDED FORCE) 0mm (STANDARD FORCE) 0mm (MEDIUM FORCE) 0mm (EXTENDED FORCE) M screw 0g,000,000 times Not required Manual/CNC coordinate measuring machines

MH0i ømm ømm MH0i MH0i MH0i MH0i mm 77mm 0 0 9.mm Probe module.7mm 0mm Set Configuration MH0i single unit Order No. 0ABN MH0i set Order No. 0ABN70 Ref. No. Description Part No. Qty Mass (kg) Remark 7 9 MH0i Probe module Cleaning tool MS-stylus tool Positioning shank Stylus Allen key (mm) Allen key (mm) Operation Manual 0ABN9 0AAV 0AAL 0 09 0AAA9 0AAA9 99MCAJ 0. 0.0 0.0 0.00 0. 0.00 0.00 0.00 0. STANDARD TYPE For cleaning the stylus module For attaching/detaching the stylus øx0 (standard stylus) 7 MH0i MH0i 0 0 9 Standard for e e e

MH0 This trigger probe has a manually operable probe head for coordinate measuring machines. The probe module part has an outside diameter as small as ø. mm, which greatly aids in probing complex portions of a workpiece. Other probe modules employing an extension either 0 mm long or 70 mm long are also provided. The operator can change the probe orientation in an optional direction by hand (simply loosen the knob on the right-hand side and change the position, then re-fasten the knob). No Allen key or other tools are required for the positional change. MH0 Specifications MH0 Measuring direction Position change Repeatability ( ) Directionality (XY: D) Directionality (XY: D) Required force to XY generate trigger signal Amount of over-travel Required force to achieve over-travel Maximum stylus length XY XY Stylus mounting method Mass of a single probe unit Durability Probe head Applicable models ±X, ±Y, + Manually for A axis (vertical direction): ±9º, and for B axis (horizontal direction): To be fixed to optional direction in range of ±00º 0. m or less ±0. m or less (with the STANDARD FORCE 0mm stylus), ±. m or less (with the 0mm stylus) ± m or less (with the STANDARD FORCE 0mm stylus), ± m or less (with the 0mm stylus) 0.0N (STANDARD FORCE), with the 0mm stylus 0.N (MEDIUM FORCE), with the mm stylus 0.N (EXTENDED FORCE), with the 0mm stylus 0.7N (STANDARD FORCE).9N (MEDIUM FORCE).N (EXTENDED FORCE) XY±º +.0mm (STANDARD FORCE) +.7mm (MEDIUM FORCE) +.mm (EXTENDED FORCE) 0. to 0.N (STANDARD FORCE) 0. to 0.N (MEDIUM FORCE) 0. to 0.N (EXTENDED FORCE).N (STANDARD FORCE) 7N (MEDIUM FORCE) 0N (EXTENDED FORCE) 0mm (STANDARD FORCE) 0mm (MEDIUM FORCE) 0mm (EXTENDED FORCE) M screw g (Probe body: g, Probe modulel: 9g),000,000 times Essential: PH0M/PH0MQ/MIH/PH Manual/CNC coordinate measuring machines

9º MH0 ø Unit: mm MH0 90 7 Center Clamp 9º 0 Probe module Rotating ±00º Set Configuration MH0-set standard configuration Order No. 0AA77 No. Description - MH0 MH0 - TP0 standard module kit No. - Stylus 0AA7 - Cleaning kit - MS-stylus tool Operation Manual Certificate Part No. 0AA7 0AAV 07 0AAL 0 Qty Mass (kg) Remark 0. 0. 0.0 Probe head main unit Measuring force (small) øx0 (standard stylus) For cleaning the probe module connection Stylus attachment tool - - - - RENISHAW MH0 -

PH0M/PH0MQ Motorized Probe Head change This probe head can automatically control the position of a probe attached at the end. (This position change can be performed, during manual operation, by simply specifying the angle through the supplied control box or the dedicated software, or by re-calling the position from memory, if it has stored for automatic position change.) When a polyhedral object is measured with a probe without the change of position function, the following operation must be conducted: attach a cross-stylus, or multiple styli, on the mount in order to measure the top surface with one facing downward, and measure the side surface with one facing sideways. However, if the workpiece has a complex geometry, probing to the target position may be obstructed because the unused stylus can interfere with the workpiece. Also, the measuring operation in which the stylus needs be attached at the specified angle may become problematic if position change is not possible. Moreover, this automatic position change allows for measurement to be completed in much less time than the automatic stylus change method, reducing the total number of man-hours required to perform measurement with the coordinate measuring machine. Since the PH0M/PH0MQ can set its position to a maximum of 70 orientations, even one stylus can function as if 70 styli are attached. In addition, since this probe head has a repeatability to the same position as high as σ 0.μm, it does not require re-calibration for measurement in which the same position must be repeatedly called. At the end of this head various probes, including but not limited to a touch trigger probe, scanning probe, vision probe, laser probe, and screw depth measuring probe, etc,. can be mounted. Furthermore, these probes can be easily replaced by means of the probe changer (optional), which achieves full-automatic measurement on a wide range of measurement objects. * Note that some probes is not compatible with this automatic probe change. PH0M/PH0MQ specifications Position change Repeated positioning accuracy Mountable probe Extension Applicable models Horizontal direction Vertical direction ʺ 0. m 0º (at 7.º increments, positions) 0 to 0º (at 7.º increments, positions) MTP000, TP7M, TP00, TP0, TP-W, QVP, SP, SP00XE, MPP-0 Note that some combinations are prohibited on the same system. PEM, PEM, PEM, PAA, PAA, PAA More than one extension cannot be joined for use. However, combined use of PAA+PFCF, PAA+PFCF, and PAA+PFCF are permitted. Use on an extension is not permitted for the WIprobe/LC0/LC00/QVP. CNC coordinate measuring machines

PHC0- PH0M/PH0MQ Motorized Probe Head mm ømm PH0MQ adapter mm 0mm mm 7mm 7mm Autojoint section 0mm Autojoint section mm PAA PECF 0mm PECF 00mm PECF 00mm 00mm PAA 0mm PEM 00mm PEM 00mm PEM Set configuration No. Description Part No. Qty Remark Mass (kg) PH0M head set PH0MQ head set HCU- PHC0- (RSC) PAA User's Manual PH0M head Joint key S0 Allen key (nominal.) Allen key (nominal ) Allen key (nominal.) PH0MQ head Joint key S0 Allen key (nominal.) Allen key (nominal.) * 77 907 0AAA9 0AAA9 * 77 907 0AAA9 0AAN0 0AAR7 9090 99MCA0 Controller for positioning the probe head Interface with the machine-side CPU (for error display) Adapter for mounting the TP00 onto the PH0M User's Manual for PH0M head.0.0 0.. 0.0 0. * Each part number will differ depending on the CMM main unit/probe that uses it. Some additional parts are also available. 7

MIH Manual Probe Head The MIH has such a capability that permits its position (probe orientation) to be manually changed to maximum kinds of orientations at a positioning repeatability of σ.μm. For measurement of a complex three-dimensional form that requires repeated changes in the probe orientation, preliminary registration of required positions can eliminate recalibration after each positional change, therefore improving the measurement efficiency at large. The current position can of course be confirmed on the LCD display of the MIH main unit. The MIH can employ any probe extension that is a maximum of 00 mm long. An example combination of the TP-W and a 0 mm stylus can extend the probe s reach to approximately 00 mm. MIH Position change Repeated positioning accuracy Mountable probe Extension Applicable models Horizontal direction ±0º (at 7. increments, positions) Vertical direction 0 to 0º (at 7. increments, positions) ʺ. m TP00, TP0, TP-w PAA (PAA+PECF, PAA+PECF, PAA+PECF), PAA, PAA Manual coordinate measuring machines

MIH Manual Probe Head ømm 7.mm mm RENISHAW MIH Autojoint section ømm Set configuration No. Description Part No. Mass (kg) Qty 7 MIH head kit set Order No. 0AAB MIH head Joint key S0 Allen key (nominal ) Allen key (nominal.) Battery PXL Wooden box for MIH PAA Single-ended wrench Double-ended wrench Positioning shank Certificate User's Manual 0AAB7 77 0AAA9 0AAA9 0AAB 0AAB9 9090 09. 0.0 0.0 0.00 0. 0.00 0.0 Remark Traveling angle: Horizontal (B axis) ±0º (7.º steps, positions) Vertical (A axis) 0 to 0º (7.º steps, positions) Spatial positioning accuracy: ±0.mm (where PAA+TP-W+ø stylus+ewl7. is used) Repeated positioning accuracy ( ):. m (in the same case as above) Mass: Approx. 70g For attaching the probe For adjusting the positioning block, or battery replacement For attaching the shank V lithium cell (Manufacturer: Duracell) Adapter for connecting the MIH and probe. Length: mm For fastening the TP and extension For fastening the TP and extension To be attached on the MIH head (Mitutoyo) PECF 0mm PECF 00mm PECF 00mm 00mm PEL 9

PH Manual Probe Head Manual probe head for use with the TP00, TP0, and TP-W. The operator can change the probe orientation to an optional direction by hand. It is possible to insert a probe extension that is a maximum of 00 mm long. PH specifications Position change Mountable probe Extension Applicable models Horizontal direction 0º (at º increments) Possible in a non-stop manner, if the head is rotated along with the ømm shank unit. Vertical direction ±º (non-step) TP00, TP0, TP-W PECF, PECF, PECF Manual/CNC coordinate measuring machines 0

PH Manual Probe Head ømm ømm mm 0mm M ø0mm PECF 0mm 00mm PECF 00mm PECF An example connection of PECF

ACR- Releasing the lock Engaging the lock The ACR is an automatic probe changer for use with the PH0M/PH0MQ. It is essential for full-automatic measurements where the currently employed probe does not have the capability of automatic stylus change but the stylus diameter or length must be occasionally changed, and where the contact-type probe and non-contact type probe are switched as required. In comparison to the conventional automatic probe changer, which must have a dedicated motor built in to turn on and off the lock system, is expensive, and has poor durability, the ACR has a simplified structure and improved durability because it employs a new mechanism in which the automatic probe change is performed through the CNC coordinate measuring machine s own drive system.

ACR- Unit : mm 0 7 Free area UNLOCKED.7 Free area LOCKED 0 CENTER POSITION Set configuration -port system [Order No. 0ABP9] -port system [Order No. 0ABP70] No. Description Part No. Qty Mass (kg) Remark ACR MRS KIT Auxiliary plate ACR attachment User's Manual Control ROM ACR MRS KIT Auxiliary plate ACR attachment User's Manual Control ROM 0ABN 0ABN07 0ABG9 0ABP7 0ABN 0ABN07 0ABG9 0ABP7.. 0.0 0. 0.0.. 0.0 0. 0.0 -port rack Rack base For fixture Attachment Adaptive to ACR -port rack Rack base For fixture Attachment Adaptive to ACR

Ceramic Master Ball Ceramic master ball (standard type) m or less ±0.0mm ø0 ceramic ball O (99.9%)] ø ø7. m or less 0-0.0 ø0 ceramic ball O (99.9%)] ø ø7. ø () 0 ø () 0 Base Base for a ceramic master ball 9 90. 0 Base appearance Set break-downs Set order No. Set name Ceramic master ball type Inspection Certificate Base Calibration Certificate Traceability 0ABQ0A 0ABQ0B 0ABQ00A 0ABQ00B 0ABQ0A 0ABQ0B A set A set B set B set C set C set Standard Standard Standard Standard Optional accessory for the Ceramic Master Ball Spacer 9 90. 0 Spacer appearance

MPP-00Q/MPP-00 Page SP0 Page SPM Page MPP-00 Page QVP Page 0 CF0 Page TP7M Page TP00 Page TP0 Page TP-W Page 0 MH0i Page MH0 Page PH0M/PH0MQ Page MIH Page PH Page 0 ACR- Page

One Number to Serve You Better --MITUTOYO (---9) Note: All information regarding our products, and in particular the illustrations, drawings, dimensional and performance data contained in this printed matter as well as other technical data are to be regarded as approximate average values. We therefore reserve the right to make changes to the corresponding designs. The stated standards, similar technical regulations, descriptions and illustrations of the products were valid at the time of printing. In addition, the latest applicable version of our General Trading Conditions will apply. Only quotations submitted by ourselves may be regarded as definitive. Mitutoyo products are subject to US Export Administration Regulations (EAR). Re-export or relocation of Mitutoyo products may require prior approval by an appropriate governing authority. Trademarks and Registrations Designations used by companies to distinguish their products are often claimed as trademarks. In all instances where Mitutoyo America Corporation is aware of a claim, the product names appear in initial capital or all capital letters. The appropriate companies should be contacted for more complete trademark and registration information. We reserve the right to change specifications and prices without notice. Aurora, Illinois (Corporate Headquarters) Westford, Massachusetts Huntersville, North Carolina Mason, Ohio Plymouth, Michigan City of Industry, California