HARAX circular connector



Similar documents
08. SEK IDC CONNECTORS

HARTING Ethernet Cabling 4-poles Overview

HARTING Ethernet Cabling 8-poles Overview

Amphenol C 091 A/B/D. Circular Connectors. Amphenol-Tuchel Electronics GmbH

Directory chapter 02 - DIN Power (to 6 A) Types D, E, F, FM, 2F, F9, interface connectors I/U Technical characteristics types D and E

01. HARTING RJ INDUSTRIAL RJ45 ETHERNET CONNECTORS

Rutenbeck Network Connection Box Cat. 5, shielded. Cable installation. UAE Connection Box Cat. 5 Operating Instructions.

HARTING Ethernet Cabling 4-poles Overview

HARTING Ethernet Cabling 4-poles Overview

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

400 Series - Mini USB Buccaneer

Cable Plug acc. to DIN EN , Form A

Simpler all over. Simpler all round. fully Ether. PoE+ shielded. MHz. Data Voice. MFP8 Cat.6 A Field assembly RJ45 plug

Universal plug connectors, for self-assembly

Assembly Instruction CAI- Connector with universal Endbell

Industrial circular connectors

IP 20 B.1 8 IP 65 / IP 67 B Cables B Tools B IP 20 B.2 8 IP 65 / IP 67 B Cables B Tools B IP 20 B.

Directory chapter 04

14 PHOENIX CONTACT Courtesy of Power/mation Energy Lane, Saint Paul, MN

6000 Series Buccaneer. 30 twist locking Tamperproof lock prevents accidental un-mating. Cat 5e shielded coupler Maintains shielding

Sealed Industrial Ethernet Circular IP67 Cat. 5e RJ45 Connector System

ODU MEDI-SNAP. Miniature Circular Connectors with Push-Pull Locking Made of Plastic or Metal.

7000 Series Buccaneer

EPIC CIRCON M23 Series Circular Signal Connectors

, , 0218/11-101, 0218/ UAE socket Cat. 5e, Cat. 6 A iso

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

CABLE SPECIFICATION CAN CAB RJ45-SUBD9

Position Cat5e (EMT) Modular Plug Connectors. Application Specification

gesis IP + Heavy Duty Class I, Zone 2

picomax The Pluggable Connection System

4 non-safe digital I/O channels 2 IO-Link Master V1.1 slots. Figure 1. Figure 2. Type code. TBPN-L1-FDIO1-2IOL Ident no

Standard Buccaneer - USB

Field bus connections Link structure CMS link structure CMS, B-design. Brochure

3RT1015-1BB41 CONTACTOR, AC-3 3 KW/400 V,

Tri-Rated Flexible PVC Equipment Wire

Schneider Automation Modbus Plus Network Installing Clustered Node Devices Version 2.0

6000 Series Buccaneer

Unarmored Variable Frequency Drive (VFD) Cable Termination Guide

Connecting the Channel A

FIXTURE INSTALLATION GUIDE Model T21T (Low Voltage Pendant Set 120V)

Redundancy Module QUINT-DIODE/40

Installation Manual (English) Adjustable Active DP Terminator T1-Pepper Active RS485 segment termination for non-compliant cable

Electronic overload relay EF19 and EF45

PC 4/ 4-ST-7,62. Extract from the online catalog. Order No.:

Simpler all over. Simpler all round. 500 MHz. 10 GB ether. fully shielded. Poe+ Cat.6 A. Data Voice. MFP8 Cat.6 A Field assembly RJ45 plug

Product Information. Gateway For Connecting EnDat Encoders to PROFIBUS-DP

Product data sheet. JUMO MIDAS Pressure Transmitter. Sales No. Order code JUMO AS /

400 Series Buccaneer BUCCANEER POWER. bulgin

Feed-through terminals

Fuses for Semiconductor Protection - Cylindrical Fuses. Class: Voltage ratings: Current ratings: Standards: Approvals: Features and Benefits

ETHERLINE Ethernet Cable, Connectors & Tools

LSA-PLUS Series 2 Connection and Disconnection Modules and Accessories

Product and functional description

Mounting instructions. Junction box VKK2R-8 DIGITAL. A en

Feed-through terminal block - SSK 110 KER-EX

PCB TERMINAL BLOCKS. Product Overview

User s Manual. BNC Mini-High Res, 75 Ohm Termination Kit Connector Installation Guide ( )

PHOENIX CONTACT Features

Powermate Range Pitch 7.62

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual

I NTERFACE CABLE ADAPTER MODULE

Standard Buccaneer - Ethernet

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

Specification SFTP CAT6 Network Cable 23AWG CU

HARTING mcon 3000 Introduction and features

DEK-REL- 24/1/SEN. Extract from the online catalog. Order No.:

ODU MINI-SNAP. Miniature Cylindrical Connectors with Push-Pull-Locking Series F

Digital input modules

APPENDIX A PIN-OUT OF RJ12 / RJ45 CONNECTORS. RJ12 connectors

Emergency lighting units EM powerled

M8 / M12 CONNECTOR SYSTEM

HARTING econ 3000 Introduction and features

1394 locking cables. Your locking cables for AVT IEEE 1394 cameras

with coloured cores and overall copper screen UL/CSA... 17

VDE Information. Degree of Pollution, Clearances and Creepage Distances and Insulating Materials

Communication, Signal & Data Cables

Power Supply Cables and Connectors

Series 8146/5-V37 and Series 8150/5-V37

Electronic overload relay EF65, EF96 and EF146

Set for PROFINET IO in IP20 TI-BL20-EN-PN-4

PCS0100en Persy Control Services B.V. Netherlands

Outdoor Use Waterproof I/O Connectors (Optical / Modular / Electrical) FO-BH, FO-BC, NT5, JN2 / W Series

maxon motor maxon motor control EPOS Positioning Controller Cable Starting Set Edition June 2006 part number Positioning Controller

LIEBERT VNSA Installation Sheet

Pressure monitoring equipment for oil-sf 6. bushings, type GOEK

Installation & Weatherproofing Guide for ENCOM Broadband Radios

DSD 70 Dual Channel Hall Effect Speed Sensor for Railway Applications, compliant with EN 50155

Mounting Plate / Screwdriver. Alignment Stickers Screws / Desiccant Bag / Double-sided Tape / Rubber Seal Plug / Rubber Washer

MCR1900 Media Converter 19-Slot Chassis

R&Mfreenet Advanced Cat 6 A Unshielded Connection Module

Cat7/Class F New Installation Concept New infrastructure. Handbook

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

Micro Contactors. Micro Contactor Relays. Micro Contactors With Solder Pins. Coil voltages. Micro Reversing Contactor. Technical Data.

Times Microwave Systems Hermetically Sealed Assemblies

UNITRONIC Data Communication Systems

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Accelerating Light. Copper Cabling Solutions. Category 6A

Transcription:

Show navigation HARAX circular connector Technical characteristics Specifications IEC 60 352-4 IEC 60 9475-2 Approvals HARAX M8-S/M12-S Rated voltage Rated current Diameter of individual strands Conductor insulation material Conductor diameter Cable diameter 32 V 4A 0,14 mm² - 0,34 mm² AWG 26-22 > 0.1 mm PVC / PP M8-S: 1.0 mm - 1.6 mm M12-S: 1.0-1.6 mm M8-S: 3.2-5.4 mm M12-S: 4 mm - 5.1 mm Temperature limits - 25 C... + 85 C Temperature during connection - 5 C... + 50 C Degree of protection IP 67 same cable cross section 10 times HARAX M12 angled Working voltage 32 V Working current 4A Wire gauge 0,25 mm² - 0,5 mm² AWG 24/7-22 Diameter of individual strands > 0.1 mm Conductor insulation material PVC Conductor diameter 1.2 mm - 1.6 mm Cable diameter 4 mm - 5.1 mm Temperature limits - 25 C... + 85 C Temperature during connection - 5 C... + 50 C Degree of protection IP 67 same cable cross section 10 times HARAX M12-L Rated voltage 50 V http://www.harkis.harting.com/webhelp/gbhangeraete/webhelp/harax/adapterm8_m12.htm (1 of 7)14/02/2006 10:31:51

Rated current 6 A 0.34 mm² - 0.75 mm² AWG 22-18 Diameter of individual strands > 0.1 mm Conductor insulation material PVC Conductor diameter 1.6 mm - 2.0 mm Cable diameter 5.5 mm - 8 mm Temperature limits - 25 C... + 85 C Temperature during connection - 5 C... + 50 C Degree of protection IP 67 same cable cross section 10 times HARAX M12-L screened version Ethernet, D-coded Profibus Rated voltage 32 V 32 V Rated current 4 A 4 A 0.25 mm² - 0.34 mm² AWG 24-22 0.25 mm² - 0.34 mm² AWG 24-22 Diameter of individual strands > 0.1 mm > 0.1 mm of Solid Result pending AWG 22/1 wire Conductor insulation material PVC PVC Conductor diameter 1.2 mm - 1.6 mm 2.0 mm - 2.6 mm Cable diameter 5.5 mm - 7.2 mm 7 mm - 8.8 mm Temperature limits - 25 C... + 85 C - 25 C... + 85 C Temperature during connection - 5 C... + 50 C - 5 C... + 50 C Degree of protection IP 67 IP 67 Coding d-coding b-coding / reverse key same cable cross section 10 times 10 times Transmission characteristics acc. to DIN EN 50 173 - M12-L A-coded Adapter M12-RJ45 Rated voltage 32 V - Rated current 4A - 0,25 mm² - 0,34 mm² - AWG 24-22 Diameter of individual strands > 0.1 mm - of Solid wire Works with AWG 22/1 - Conductor insulation material PVC - Conductor diameter 1.6 mm - 2.0 mm - Cable diameter 7.0 mm - 8.8 mm - Working temperature - 25 C... + 85 C - 25 C... + 85 C Temperature during connection - 5 C... + 50 C - 5 C... + 50 C Degree of protection IP 67 IP 65 / 67 Coding a-coding - Number of terminations with same cable cross section 10 10 Transmission characteristics acc. to - DIN EN 50 173 http://www.harkis.harting.com/webhelp/gbhangeraete/webhelp/harax/adapterm8_m12.htm (2 of 7)14/02/2006 10:31:51

HF Properties acc. to DIN EN 50173 1= Limit acc. to DIN EN 50173, Category 5 2= Pin allocation diagonal wire pair 1/3 <-> 2/4 3= Pin allocation diagonal wire pair 2/4 <-> 1/3 Derating Diagramme The current carrying capacity is limited by maximum temperature of materials for insert and contacts including terminals. The current capacitycurve is valid for continuous, not interrupted current-loaded contacts of connectors when simultaneous power on all contacts is given, without exceeding the maximum temperature. Control and test procedures according to DIN IEC 60512-3. M8-S, 4 poles M12-S, 4 poles http://www.harkis.harting.com/webhelp/gbhangeraete/webhelp/harax/adapterm8_m12.htm (3 of 7)14/02/2006 10:31:51

1 = wire gauge 0,25 mm² 2 = wire gauge 0,34 mm² M12, 4 poles, angled 1 = wire gauge 0,25 mm² 2 = wire gauge 0,5 mm² http://www.harkis.harting.com/webhelp/gbhangeraete/webhelp/harax/adapterm8_m12.htm (4 of 7)14/02/2006 10:31:51

M12-L, 4 poles M12-L, shielded 1 = wire gauge 4 x 0,34 mm² 2 = wire gauge 4 x 0,75 mm² Assembly manual HARAX 1. Strip cable 2. Assemble HARAX elements 3. Cut off cable ends 4. Screw connector (1) Nut (2) Strain relief (3) Insert Screw the nut onto the insert until a stop is noticeable. Note! For reconnection cut off the used cable ends and repeat steps 1 to 4. http://www.harkis.harting.com/webhelp/gbhangeraete/webhelp/harax/adapterm8_m12.htm (5 of 7)14/02/2006 10:31:51

Assembly instruction for shielded HARAX M12-L 1. Strip cable 2. Assemble HARAX elements, twist screening braid and push it into the sealing slot 3. Slide ring over the sealing cut off cable ends and the screening braid. 4. Screw the connector (1) Nut (2) Strain relief (3) Insert Note! For reconnection cut off the used cable end and repeat steps 1 to 4. http://www.harkis.harting.com/webhelp/gbhangeraete/webhelp/harax/adapterm8_m12.htm (6 of 7)14/02/2006 10:31:51

http://www.harkis.harting.com/webhelp/gbhangeraete/webhelp/harax/adapterm8_m12.htm (7 of 7)14/02/2006 10:31:51