Application Requirement



Similar documents
The photoionization detector (PID) utilizes ultraviolet

ABSTRACT INTRODUCTION

Buckeye Detection Systems Fixed Detection Systems Application Survey

P R O D U C T S P E C I F I C A T I O N MSA Ultima X Series Sensor/Transmitter Specification

Continuous Monitoring of Flue and Combustible or Hazardous Gases and Vapors

Advanced Solutions for Gas Monitoring

Ultima X Series Gas Monitors

Engineering Specifications XNX Universal Transmitter

TABLE OF CONTENT

Online Infrared Flue Gas Analyzer Gasboard 3000

White Paper. Detecting Hydrogen Sulfide Gas and Understanding its Danger in the Field. Introduction

Portable Gas Analyzer with Wireless Transmission of Gas Concentrations and GPS Coordinates

Q U A D S C A N I I GENERAL User Interface Enclosure Display QUADSCAN II Temperature Range RECEIVER DISPLAY Sensor Weight Optional Relay Enclosure

1/11 CO2 DOSAGE SYSTEMS. CO2 dosage system consists of following parts;

Control Device Requirements Charts For Oil and Gas Handling and Production Facilities

How To Use An Irius Pid Detector

THE DETECTION OF GREENHOUSE GASES

Gas and flame detection Stack gas and dust analysis

Ammonia Detection System Codes and Design Specifications. Brian EuDaly, P.E. Calibration Technologies, Inc.

Carbon Dioxide Membrane Separation for Carbon Capture using Direct FuelCell Systems

FLARE MONITORS FLARE MONITOR (FM) PILOT MONITOR (PM) FLAME INTENSITY (FI)

Selecting Gas Detectors For Confined Space Entry By H. Ross Humphry Canadian Safety Equipment Inc.

Automotive Air Quality Sensors: industrial innovations to protect people s health

Dew-Point Measurement Solutions

Combustible Gas Safety Monitoring: Infrared vs. Catalytic Gas Detectors

DrägerSensor EC Electrochemical Sensors Sensor for Fixed Gas Detectors

EuroFID Total Hydrocarbon Analyzer. Precise Determination of Total Hydrocarbons in Air for Corrosive as well as Condensing Gases

VIBRATION MONITORING OF FANS INSTALLED IN ROAD TUNNELS

ALTAIR 5X Multigas Detector Bid Specification

MATHESON STACK EMISSION CALIBRATION PROGRAM. Experience the MATHESON Commitment to Supply Chain Excellence

UFGS (February 2011) UNIFIED FACILITIES GUIDE SPECIFICATIONS

How Sensors Work. How Oxygen, Electrochemical Toxic, and Metal Oxide Semiconductor Sensors Work *

Global Gas Detection and Monitoring Solutions

Triple Waveband Infra-Red Flame Detection

PortaSens ll G AS DETECTOR

The Ambient Air Monitoring System

MSA Fixed Gas & Flame Detection for the Oil, Gas & Petrochemical Industries

MERIDIAN UNIVERSAL GAS DETECTOR TECHNICAL DATA PACKAGE

Relative Humidity Sensors, Transmitters and Calibration Products Relative Humidity Measurement and Calibration

The Breather Box. High Performance Grade-D Breathing Air Filtration system. BB50-cO

sierra monitor corporation Fire and Gas Detection Systems

Ammonia Detection System Codes and Design Specifications

Ventostat Wall Mount. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. GE Measurement & Control. Features:

Process Instrumentation

Gas sensors for greenhouse measurements

Environmental Equipment, Inc. IMR 5000 Continuous Flue Gas Monitoring System IMR 5000

Sieger Searchpoint Optima Plus

Chlorine Gas Detection System Operation & Maintenance

EX 2000/EX 2000 C/ GD 2000/GDP

Fire & Gas Detection; Reducing Risks in Rail Loading/Unloading Facilities. By Todd Spicer Technical Specialist Spartan Controls Fire & Security

Sensor for Ammonia West 83 rd Terrace or fax

WD-AMX Water Detection Controllers

PolyGard Carbon Monoxide CO Transmitter ADTX3 1110

Technical Guidance. Application of Portable Gas Detectors in the Petrochemical Industry. Made simple. Introduction

RAEGuard EC FGM-13XX

SMART SENSOR COLLECTION

DissolvedOxygenMonitor

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

POLLUTION CONTROL TECHNOLOGIES Vol. I - Effluent Gas Monitoring - J. Versieren, A. Buekens and K. Schroyens

Fire & Security DETECTORS

MSA Fixed Gas & Flame Detection for the Water & Wastewater Industries

Analytical Instruments Smart Analyzer 90 Type SMA

Lightweight, compact, ergonomic, safe POLARIS FID. Portable TOC Analyser for Stack Emissions

SECTION NOx, CO AND NATURAL GAS DETECTION, MONITORING AND ALARM CONTROL SYSTEMS

Introduction. Motor Types

Title: Standard Operating Procedure for Thermo-Miran SapphIRe portable gas analyzer

ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL

CD-Pxx-00-1 Series Duct Mount CO 2 Transmitter

Introduction to Electronic Signals

EASIDEW PORTABLE HYGROMETER INSTALLATION, OPERATION AND MAINTENANCE MANUAL

Lecture 35: Atmosphere in Furnaces

TYPE 65UV CEX Integrated Flame Scanner with Internal Flame Relay and Analog Output

Electronic Flow Switches

Gas Detection & Alarm Systems. for Industrial Use Product Guide

Temperature & Humidity SMS Alert Controller

Temperature Compensated Charging of Lead Acid Batteries

Gas emission measurements with a FTIR gas analyzer - verification of the analysis method Kari Pieniniemi 1 * and Ulla Lassi 1, 2

Model: DC-A2IO Advanced HVAC Controller

USB-500 Series Stand-Alone, Low-Cost Data Loggers

User Manual for CH-PFC76810

Original instructions Tina 3A/Aps Adaptor unit

Series B14 Monitor System

Lockout Specification BW Clip Maintenance-free single gas detector

Tina 2A/B Adaptor unit

Isolating Barriers for our sensors A5S1 in Ex-areas Series D461

1/2 NPTM mm Nose cone fitting Ideal for clean liquids

How to Select a Flame Detector

Gas Detection for Refining. HA University

Air Sampling for Gases and Vapors. Patrick N. Breysse, PhD, CIH Peter S.J. Lees, PhD, CIH Johns Hopkins University

Electronic Diesel Control EDC 16

Fractional Distillation and Gas Chromatography

Long Distance Industrial Wireless Transmitters and Receivers

Laser Diode Gas Sensors

Thermal Mass Flow Meters

MP-4000 Alarm List (Software version or later)

Application Note AN1

On-line Dissolved Gas Analysis

SMS GSM Alarm Messenger

THE HUMIDITY/MOISTURE HANDBOOK

An easy and flexible way to do gas detection.

Transcription:

Hazardous Gas Monitors Sensor Selection Overview Safety Monitoring (LEL) Toxic Limit Detection (PEL) Leak Detection Personal Safety Application Requirement Exposure Assessment (TWA) Ambient Air Quality Compliance Monitoring LIMIT DETECTION ALARM QUALITATIVE & QUANTITATIVE ANALYSIS Toxic Gases Monitors Monitor Type: Electrochemical Solid-State Analyzers Target Gas: O 3 SO 2 Analyzer Type: UV Photometers UV Fluorescence Combustible Gases Volatile Organic Compounds Catalytic Solid-State Infrared Photoionization Single Gas (Online) Air Quality Monitor Continuous Emission Monitor NO x THC* CO CO 2 SO 2 O 2 Chemiluminescence Flame Ionization Infrared Paramagnetic; Zirconium Oxide; Electrochemical Total Hydro- Carbons Flame Ionization Most UV/IR Absorbing Gases UV/IR Spectrometer Other Gases Thermal Conductivity Colorimetric Multi- Gas (Laboratory) Most IR Absorbing Gases Most Gases Fourier Transform IR Mass Spectrometer Gas Chromatograph *Total hydrocarbon

Chapter 8 Chapter 8 Each of the following sensors electrochemical, catalytic bead, solid state, infrared and photoionization detectors must meet certain criteria to be practical for use in area air quality and safety applications. Some of the basic requirements are: 1. The sensor should be designed for a housing that is small and rugged. The sensor should be suitable for use in hazardous locations and harsh environments, and, it should also be explosion-proof. The sensor should be cost-effective, designed for installation and use in industrial production areas, and installable at a reasonable cost. 2. For portable applications, the instruments should have reasonable energy consumption and the option of powering the instruments with batteries should be easily available. The instruments should be small and portable so they can be carried easily. They should be safe for use in industrial environments. Preferably, the instruments should be certified as intrinsically safe for use in a hazardous area. 3. The operation and maintenance of the instruments should be easily performed by regular plant personnel with minimal special training requirements. 4. In stationary installations, the sensors should be able to function continuously and reliably for a period of time, preferably longer than 30 days. The sensor 103

Hazardous Gas Monitors should be able to function in an industrial environment for at least two years or longer and should be replaceable or renewable at a reasonable cost. It should be easy to install into a multi-point system and be managed by a controller or a computer controlled distribution system. 5. The cost of the instruments should be reasonable so that multiple sensors can be installed to effectively protect the area. Four of the five sensors discussed in this book all meet the above criteria. The exception is the photoionization detector. The PID is a good detector for portable applications but is limited by the lamp because it has a relatively short life expectancy and the frequency of maintenance required may not be practical for stationary applications. However, there are PID stationary instruments available that can be useful as long as users are aware of the limitation. There are other types of sensors which meet the above criteria, but most have limitations. For example, thermal conductivity sensors are mostly used for high concentration applications and are not widely used as gas monitors. Factors to Consider When Selecting Sensors One of the most frequently asked questions regarding sensors is: Which sensor is the best? Of course, there is no simple answer to this question. Each sensor has certain capabilities and limitations, and thus the suitability of a given sensor depends largely on the application in which it is to be used. Thus, to choose the correct sensor, one must first properly define the application. The illustration on page 102 shows an overview of various application requirements and their detection technologies. It is common for manufacturers to exaggerate the capabilities of the sensors that they offer and downplay sensors that they do not offer. 104

Chapter 8 In determining which sensor to use for a given application, the following factors/observations should be considered: A. Realistically define what objective one is trying to accomplish and define an instrument specification that meets the minimum requirements. The specifications should define the gases and ranges of the sensors. The ranges or the concentration of the gases to be measured should be 3 to 5 times the actual monitoring concentration. As with a voltmeter, one should always select a range higher than the actual voltage to be measured. For example, select a 50-volt range to measure a 12-volt battery. B. Determine the background gases in the monitoring area. In cases where the background gases cannot be determined, a representative sample should be analyzed. A major cause of sensor failure is the presence of background gases that the instrument s manufacturers did not take into consideration. The selectivity or specificity of the sensor must be acceptable for the application. C. The temperature ranges in which the sensor is to be installed should be within the sensor specifications and should be suitable for the gases to be monitored. For example, jet engine fuels have very low vapor pressure. It is useless to install a sensor to measure the combustible range in a hangar if the temperature will never exceed 100 F because the vapor concentration cannot reach combustible levels. In this example, it is more appropriate to measure in ppm ranges. The temperature changes between day and night, and during summer and winter, should also be considered. A wide temperature change 105

Hazardous Gas Monitors can cause moisture condensation. This is particularly important in a confined space such as a closed container where air circulation is poor. D. A typical specification for humidity is 95% noncondensating. The occurrence of condensation is a function of temperature change, as seen on wet windows and car windshields in the morning. Normally, there is no problem in normal industrial background environments, even during the hot summer months in coastal areas such as the Gulf of Mexico, as long as the air circulation is normal. Areas with poor air circulation can often be the cause of condensation. Both solid-state and catalytic sensors have heated elements. In addition, their transmitters are designed to operate at 14-24 VDC, which generates heat. Therefore, the sensor transmitters are always a few degrees warmer than the environment in order to minimize the possibility of condensation. Electrochemical sensors normally require relatively much less power; therefore, the temperature of their transmitters is similar to the surrounding temperature. In this case, it is easier for condensation to occur. E. In applications requiring the sensors to be constantly exposed to gas, special considerations are required and the sensor specifications and the suppliers of the sensors may need to be consulted. A properly designed sampling system may make difficult or otherwise impossible applications possible to handle. It is difficult to mention every consideration needed, but a carefully evaluated and studied application can yield savings in both time and money. 106

Chapter 8 With the specifications of the sensors, one can decide which sensor best meets one s requirements. There is no general consensus that establishes which sensor is the best for a given application. Hence, the information that follows contains some guidelines that may be helpful in making the proper selection of a sensor. Toxic versus Combustible Gas Monitoring Gas monitoring applications are generally classified into toxic or combustible range monitoring. Toxic gas monitors are generally used for human health protection and the ranges of the monitors are 3 to 5 times higher than the permissible exposure limits. For most gases, ranges are in ppm concentrations. For combustible applications, ranges are typically 100% lower flammable limits or a fraction of these ranges, such as 50% LFL. The gas concentrations are high and are generally in the range of several percent. In other words, for toxic gas applications, a sensor must be able to measure gases at low concentrations while, for combustible gas monitoring, a sensor must measure high gas concentrations. Summary Electrochemical Sensors. Except for oxygen applications, electrochemical cell sensors are designed to be used as toxic gas monitors. These sensors are only suitable for low concentration ppm ranges. For portable applications, the electrochemical sensor has many advantages: it has very low power consumption, responds quickly to gas, and is not affected by humidity. Also, the sensors are only exposed to gas periodically, which maximizes the sensor life. Electrochemical sensors are therefore a good choice for portable instruments. Electrochemical sensor life expectancy is two years; however, depending on the application, it can be much shorter. The cost 107

Hazardous Gas Monitors of replacement sensors is high, especially when the number of instruments in use is large. The annual budget and labor to keep the instruments functioning need to be considered. There are approximately 20 gases that can be monitored by electrochemical sensors. For the rest of the gases (for ppm ranges), solid-state sensors or PIDs will need to be used. Catalytic Sensors. In portable combustible gases in the LEL ranges, a catalytic sensor is good for normal, simple applications. The sensors can last for a long time because they are used sporadically in portable applications. Catalytic sensors are relatively inexpensive but one has to make sure they are made by reputable suppliers. Infrared and Solid-State Sensors. For gases that can poison the catalytic sensors and make them impossible to use, the choice is between infrared sensors and solid-state sensors. Depending on the gases to be detected, infrared sensors have the better performance but detection of gases is limited. On the other hand, solid-state sensors can detect most chemicals in the LEL ranges. In stationary applications, the sensors are constantly exposed to environmental background gases. For toxic gas applications, it is generally favorable to use solid-state sensors, especially when the number of sensors is sizable. In applications where interference can be a problem, it is best to study the sensor specifications and to consult with the supplier. For stationary combustible gas applications, the choice is among catalytic sensors, solid-states sensors and infrared sensors, which are fully described in Chapters 4, 5, and 6 respectively. There are no standardized specifications for a gas monitor. The following table entitled Typical Specifications for Gas Monitoring Instruments is a summary of several requests for quotation from cus- 108

Chapter 8 tomers and is presented here as a reference. Typical Specifications for Gas Monitoring Instruments Remote Sensor Transmitter Specifications Gas to Be Monitored: Methyl Bromide, 0 500 ppm. Sensor: Solid-state sensor Temperature: 10 o C to 45 o C. Humidity: 95% RH, noncondensing. Accuracy: 5% Response Time: 50 seconds to 90% full scale Background: Normal environmental conditions Transmitter shall be certified for use in Class 1, Div. 1, Groups B, C, D areas. Provides functional adjustments without the need to open the transmitter s cover, and provides protection for outdoor applications. Power: 14 VDC to 24 VDC Output: 4 20 ma linear output. Controller Specifications 1. Four-channel control unit, microprocessor-based. 2. Independent digital display of reading for each channel. Provides calibration functions, three alarm settings, and diagnosis functions. 3. Three-level alarm set points (low, mid, high) with LED indicator for each alarm. 4. Relays: SPDT, 5 amp. 220 VAC max. resistive Common relays for each alarm level (3 relays per channel) Options: Individual relays for each alarm level ( 3 relays per channel) Fault relays for each channel, indicating electrical fault of the sensor 5. 4-20 ma analog output signal for each channel. 6. Wall-mounted weatherproof NEMA 4X enclosure. 7. Provide 24 VDC, 500 ma for each sensor module, accepts and processes 4-20 ma transmitter output signal. 109