APPLIED. Measuring Caffeine Concentration. Application Summary. Analytes: caffeine (C 8 H 10 N 4 O 2



Similar documents
Austin Peay State University Department of Chemistry Chem The Use of the Spectrophotometer and Beer's Law

Spectroscopy. Biogeochemical Methods OCN 633. Rebecca Briggs

QUANTITATIVE INFRARED SPECTROSCOPY. Willard et. al. Instrumental Methods of Analysis, 7th edition, Wadsworth Publishing Co., Belmont, CA 1988, Ch 11.

Problem Set 6 UV-Vis Absorption Spectroscopy Express the following absorbances in terms of percent transmittance:

A Complete Solution for Method Linearity in HPLC and UHPLC

ATOMIC ABSORTION SPECTROSCOPY: rev. 4/2011 ANALYSIS OF COPPER IN FOOD AND VITAMINS

ANALYSIS OF ASPIRIN INFRARED (IR) SPECTROSCOPY AND MELTING POINT DETERMINATION

AspiroTM. EOR Polymers and Surfactants

UV-Vis spectrophotometers

EXPERIMENT 11 UV/VIS Spectroscopy and Spectrophotometry: Spectrophotometric Analysis of Potassium Permanganate Solutions.

Chemistry 321, Experiment 8: Quantitation of caffeine from a beverage using gas chromatography

Determination of Food Dye Concentrations in an Unknown Aqueous Sample Using HPLC

Determination of Caffeine in Beverages HPLC-1

The photoionization detector (PID) utilizes ultraviolet

Application Note: Absorbance

Title: Standard Operating Procedure for Thermo-Miran SapphIRe portable gas analyzer

Ultraviolet Spectroscopy

About Coffee and Refractometers Voice Systems Technology, Inc. (VST)

Fundamentals of modern UV-visible spectroscopy. Presentation Materials

Project 5: Scoville Heat Value of Foods HPLC Analysis of Capsaicinoids

HPLC Analysis of Acetaminophen Tablets with Waters Alliance and Agilent Supplies

INTRODUCTION. The principles of which are to:

Uses of Derivative Spectroscopy

Introduction to HPLC. Basic Module in Bioorganic Chemistry January 16, 2007 Johannes Ranke. Introduction to HPLC p.1/17

Fiber Optic Sampling by UV/Vis and UV/Vis/NIR Spectroscopy

Extraction of Caffeine from Energy Drinks

the importance of ph in water purification the importance of ph in water purification Water Purification Systems UK

Optimize Your Process Operations by Improving Process Monitoring

LIQUID CHROMATOGRAPHY HOW MUCH ASPIRIN, ACETAMINOPHEN, AND CAFFEINE ARE IN YOUR PAIN RELIEVER? USING HPLC TO QUANTITATE SUBSTANCES (Revised: )

EXPERIMENT 5. Molecular Absorption Spectroscopy: Determination of Iron With 1,10-Phenanthroline

Reversed Phase High Presssure Liquid Chromatograhphic Technique for Determination of Sodium Alginate from Oral Suspension

Optical or Acoustic Process measurement of liquids Turbidity Colour Oil in Water Water in Oil Oil on Water Process UV- Photometry

Organic Chemistry Tenth Edition

Determination of Fat in Dried Milk Products Using Accelerated Solvent Extraction (ASE)

Reaction Stoichiometry and the Formation of a Metal Ion Complex

Experiment #5: Qualitative Absorption Spectroscopy

Unique Software Tools to Enable Quick Screening and Identification of Residues and Contaminants in Food Samples using Accurate Mass LC-MS/MS

KINETIC DETERMINATION OF SELENIUM BY VISIBLE SPECTROSCOPY (VERSION 1.8)

FTIR Instrumentation

METHOD 9075 TEST METHOD FOR TOTAL CHLORINE IN NEW AND USED PETROLEUM PRODUCTS BY X-RAY FLUORESCENCE SPECTROMETRY (XRF)

Chemistry 111 Lab: Intro to Spectrophotometry Page E-1

Op Amp Circuit Collection

UV/VIS/IR SPECTROSCOPY ANALYSIS OF NANOPARTICLES

ProteinChip Energy Absorbing Molecules (EAM)

Chemical Measurement Solutions

Online Infrared Flue Gas Analyzer Gasboard 3000

Simultaneous determination of aspartame, benzoic acid, caffeine, and saccharin in sugar-free beverages using HPLC

How to measure Chlorophyll-a

Programmable-Gain Transimpedance Amplifiers Maximize Dynamic Range in Spectroscopy Systems

Thermo Scientific Dionex Chromeleon 7 Chromatography Data System Software

How To Choose A Total Organic Carbon Analyzer

13C NMR Spectroscopy

3 - Atomic Absorption Spectroscopy

Solutions for Process Analytics

m/z

VALIDATION OF ANALYTICAL PROCEDURES: TEXT AND METHODOLOGY Q2(R1)

# LCMS-35 esquire series. Application of LC/APCI Ion Trap Tandem Mass Spectrometry for the Multiresidue Analysis of Pesticides in Water

Introduction to Fourier Transform Infrared Spectrometry

CHEM 51LB: EXPERIMENT 5 SPECTROSCOPIC METHODS: INFRARED AND NUCLEAR MAGNETIC RESONANCE SPECTROSCOPY

Strategies for Developing Optimal Synchronous SIM-Scan Acquisition Methods AutoSIM/Scan Setup and Rapid SIM. Technical Overview.

Back to Basics Fundamentals of Polymer Analysis

Various Technics of Liquids and Solids Level Measurements. (Part 3)

Density Measurement. Technology: Pressure. Technical Data Sheet INTRODUCTION. S min =1.0 S max =1.2 CONSTANT LEVEL APPLICATIONS

Advanced Solutions for Gas Monitoring

Decaffeination of Raw, Green Coffee Beans Using Supercritical CO 2

4. It is possible to excite, or flip the nuclear magnetic vector from the α-state to the β-state by bridging the energy gap between the two. This is a

Electrospray Ion Trap Mass Spectrometry. Introduction

Refractive Index Measurement Principle

Proton Nuclear Magnetic Resonance Spectroscopy

Trans Fats. What is a trans fat? Trans fatty acids, or trans fats as they are known, are certain

The DL8000 Preset Controller. The Ideal Device for Controlling and Measuring the Loading of Liquid Hydrocarbons into Transporting Tankers

Appendix 5 Overview of requirements in English

Effects of Temperature, Pressure and Water Vapor on Gas Phase Infrared Absorption by CO 2

HRMS in Clinical Research: from Targeted Quantification to Metabolomics

Upon completion of this lab, the student will be able to:

Micro Motion ELITE CMFS Series Meter

Used to determine relative location of atoms within a molecule Most helpful spectroscopic technique in organic chemistry Related to MRI in medicine

Sugar Inversion and Brix in Soft Drinks: Cobrix3 multibev Measures Both!

Chemistry 13: States of Matter

Gas emission measurements with a FTIR gas analyzer - verification of the analysis method Kari Pieniniemi 1 * and Ulla Lassi 1, 2

Raman Spectroscopy Basics

Exp 13 Volumetric Analysis: Acid-Base titration

Chapter 13 Spectroscopy NMR, IR, MS, UV-Vis

Copyright by Mark Brandt, Ph.D. 12

Determination of Moisture Content

Graphite Furnace AA, Page 1 DETERMINATION OF METALS IN FOOD SAMPLES BY GRAPHITE FURNACE ATOMIC ABSORPTION SPECTROSCOPY (VERSION 1.

Reflectance Measurements of Materials Used in the Solar Industry. Selecting the Appropriate Accessories for UV/Vis/NIR Measurements.

DIODE CIRCUITS LABORATORY. Fig. 8.1a Fig 8.1b

Improved Business Process Through XBRL: A Use Case for Business Reporting

INFRARED SPECTROSCOPY (IR)

- 1 - BISC 367 Plant Physiology Laboratory SFU

Spectrophotometry and the Beer-Lambert Law: An Important Analytical Technique in Chemistry

How to Measure 5 ns Rise/Fall Time on an RF Pulsed Power Amplifier Using the 8990B Peak Power Analyzer

Ultraviolet-Visible (UV-Vis) Spectroscopy Background Information

Automated Method Development Utilizing Software-Based Optimization and Direct Instrument Control

Application Requirement

The Control of ph and Oxidation Reduction Potential (ORP) in Cooling Tower Applications By Charles T. Johnson, Walchem Corporation

Multivariate Chemometric and Statistic Software Role in Process Analytical Technology

Lab #11: Determination of a Chemical Equilibrium Constant

Transcription:

Application Summary Analytes: caffeine (C 8 H 10 N 4 O 2 ) Detector: OMA-300 Process Analyzer (UV-Vis spectrophotometer) Introduction While it may mystify those of us that need strong coffee to get through the workday, some people actually drink decaf (decaffeinated coffee), whether for health reasons (high blood pressure, hypertension, sleep difficulties), pregnancy cautions, or personal preference. In lieu of more firm legal standards, decaf is supposed to have its caffeine content reduced by no less than 97.5% of the source coffee (USDA guideline). Accurate validation of the caffeine levels in decaffeinated coffee bean batches would reduce APPLIED TM A N A L Y T I C S 1

sensitive consumers health risks by preventing the wildly inconsistent caffeine levels among available decaf blends (as documented by the Journal of Analytical Toxicology). Moreover, producers can use real-time caffeine monitoring to conclude the decaffeination cycle as soon as the specified caffeine threshold is achieved, thus wasting no more caffeine solvent or production time than absolutely necessary. An online analysis solution would provide continuous, live caffeine measurement in an automated fashion. The High- Performance Liquid Chromatography (HPLC) methods currently used in some caffeine applications is quite costly to own and maintain while delivering slow response. Using OMA to Measure Caffeine Concentration in Decaffeination Processing While certain selective solvents are extremely effective at removing caffeine from coffee beans, many of these chemicals have been classified as carcinogenic or toxic. Though less powerful, the supercritical CO 2 extraction method is a harmless decaffeination process common in large-scale operations. Supercritical CO 2 fluid is a hybrid gaseous/liquid resource maintained by exceeding the critical temperature (31 C) and pressure (73 atm) of CO 2 ; for the supercritical CO 2 to act as an effective solvent for caffeine molecules, it actually has to be kept at more extreme conditions (around 94 C and 225 atm). These conditions are expensive to maintain, and the 10-hour process cycle is time-consuming. The caffeine extract is sold off to pharmaceutical and soft drink companies, but this only partially alleviates process cost. With real-time caffeine monitoring at ±1 ppm accuracy, the OMA-300 Process Analyzer allows decaf coffee producers to automatically end an extraction cycle when the specified caffeine maximum is reached. Doing away with the preset 10-hour cycle, this method banishes both overprocessing (which wastes production resources) and underprocessing (which upsets customers). While highly suitable for monitoring the 0-1,000 ppm caffeine range established by international standards as legally decaf, the OMA-300 s UV-Vis spectrophotometer has a true detection limit of 2 ppm caffeine, thus theoretically capable of validating a cup of perfect decaf. Importance of Using a UV-Vis Spectroscopic Method The defining advantage of the ultraviolet-visible (UV-Vis) range in caffeine analysis is the transparency of the process background to the detector. Systems using infrared (IR) spectroscopy will suffer interference from water or CO 2 because these compounds absorb IR radiation; these systems may require drying the sample or expensive sample handling. Since water and CO 2 have no absorbance in the UV-Vis range, they appear totally transparent to the OMA spectrophotometer. This is extremely important for typical caffeine applications such as:»» caffeine in supercritical CO 2 stream»» caffeine in water or liquids containing water 2

1% wt BL corrected Measuring Caffeine Concentration Dynamic Range in Caffeine Measurement Any single photodiode measurement is vulnerable to noise, signal saturation, or unexpected interference. This susceptibility to error makes a lone photodiode data point an unreliable indicator of one chemical s absorbance. As accepted in the lab community for decades, the best way to neutralize this type of error is to use collateral data in the form of confirmation wavelengths, i.e. many data points at many wavelengths instead of a single wavelength. The same principle holds true for sustaining accuracy across a very wide concentration range. An instrument that only measures one wavelength at a pre-determined absorbance peak will suffer from signal clipping: above a certain concentration, all of the signal at that wavelength will be absorbed and higher concentrations cannot be measured. The full-spectrum technology used by the OMA removes this limitation by measuring at many wavelengths simultaneously. To illustrate this capability, the spectrum below shows the shape of the UV-Vis absorbance curve intrinsic to the caffeine molecule. Each range of caffeine concentration has a most suitable wavelength region of analysis based on the relative height of the absorbance curve within that region: Caffeine Absorbance Spectrum Medium Range: 0.5-1% wt Low Range: 0-0.5% wt High Range: 1-10% wt absorbance 220 230 240 250 260 270 280 290 300 310 320 wavelength (nm) When processing the raw data from the spectrophotometer, the OMA s proprietary ECLIPSE software runs three analysis models in parallel each assigned to a unique wavelength region to measure caffeine concentration at different ranges. These parallel models ensure that the measurement always compensates for an error at a single photodiode due to overabsorbance or light saturation. Consider the example of the Low Range: when caffeine concentration rises above 0.5% wt, the sample will absorb strongly enough that the diodes measuring at the 260-284 nm region will register zero light. At >0.5% wt concentration level, these diodes cease to be reliable due to signal clipping. Meanwhile, the absorbance curve is naturally lower in the 235-260 nm region (Medium Range), and the diodes reading these wavelengths are still receiving an optimal absorbance signal. The OMA system always runs all three models simultaneously, reporting each as a separate output. Optional system logic can create a unified output which always reports from the appropriate model (Low, Medium, or High) based on the current caffeine concentration in the sample. In this manner, the OMA provides seamless dynamic range with sustained accuracy through large fluctuations. 3

Absorbance-to-Concentration Correlation In the figures below, each diamond in a curve represents a single photodiode and data point. The OMA measures absorbance at each integer wavelength from 200-800 nm and produces a caffeine absorbance curve. After being calibrated on a full spectrum of pure caffeine at known concentration, the OMA knows the absorbance-concentration correlation for each wavelength. This is the equivalent of using hundreds of single-wavelength photometers simultaneously, averaging the concentration calculated from each data point to eradicate the effect of noise at any single photodiode. Caffeine Absorbance Curves at Low Range (0.01% wt to 0.05% wt) 0.12 absorbance (AU) 0.08 0.04.05% wt.04% wt.03% wt.02% wt.01% wt 0 240 250 260 270 280 290 wavelength (nm) absorbance (AU) Caffeine Absorbance Curves at High Range (1% wt to 5% wt) 2 1.8 1.6 1.4 1.2 1 0.8 0.6 0.4 0.2 0 290 292 294 296 298 300 302 304 306 308 310 wavelength (nm) 5% wt 4% wt 3% wt 2% wt 1% wt Only a full-spectrum instrument can provide the rich raw data necessary to accurately measure caffeine concentration from very low to very high levels. 4

The specifications below represent performance of the OMA-300 Process Analyzer in a typical caffeine application. For technical details about the OMA-300 Process Analyzer, see the data sheet: http://www.a-a-inc.com/documents/aa_ds001a_oma300.pdf All performance specifications are subject to the assumption that the sample conditioning system and unit installation are approved by Applied Analytics. For any other arrangement, please inquire directly with Sales. Subject to modifications. Specified product characteristics and technical data do not serve as guarantee declarations. Application Data Performance Specifications Accuracy Custom measurement ranges available; example ranges below. 0-100 ppm: ±1 ppm caffeine 0-1,000 ppm: ±1% full scale 0-10%: ±1% full scale 5

Revised 26 July 2013 Further Reading Subject OMA Series Process Analyzers Brochure OMA-300 Process Analyzer Data sheet Advantage of Collateral Data Technical Note Location http://www.a-a-inc.com/documents/oma.pdf http://www.a-a-inc.com/documents/aa_ds001a_oma300.pdf http://www.a-a-inc.com/documents/aa_tn-202_collateraldata.pdf References McCusker, Rachel R., Brian Fuehrlein, Bruce A. Goldberger, Mark S. Gold, and Edward J. Cone. Caffeine Content of Decaffeinated Coffee. Journal of Analytical Toxicology 30.8 (2006): 611-13. APPLIED TM A N A L Y T I C S is a registered trademark of Applied Analytics Group BV. www.a-a-inc.com Headquarters + Manufacturing Applied Analytics, Inc. Burlington, MA sales@a-a-inc.com North America Sales Applied Analytics North America, Ltd. Houston, TX sales@appliedanalytics.us Europe Sales Applied Analytics Europe, SpA Milan, Italy sales@appliedanalytics.eu Asia Pacific Sales Applied Analytics Asia Pte. Ltd. Singapore sales@appliedanalytics.com.sg Middle East Sales Applied Analytics Middle East (FZE) Sharjah, UAE sales@appliedanalytics.ae Brazil Sales Applied Analytics do Brasil Rio de Janeiro, Brazil sales@aadbl.com.br India Sales Applied Analytics (India) Pte. Ltd. Mumbai, India sales@appliedanalytics.in 2013 Applied Analytics Group BV. Products or references stated may be trademarks or registered trademarks of their respective owners. All rights reserved. We reserve the right to make technical changes or modify this document without prior notice. Regarding purchase orders, agreed-upon details shall prevail. 6