Data sheet GIOD.1 Input/output module with CAN bus. ERP no.: 5204183. www.guentner.de. Data sheet GIOD.1 V_3.0



Similar documents
Modular I/O System Analog and Digital Interface Modules

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01

PCAN-B10011S Bus Converter High-speed CAN to Truck Trailer CAN. User Manual. Document version ( )

IO-DIM6 6-Channel, Digital to Analogue Converters

POINTS POSITION INDICATOR PPI4

Points Position Indicator (PPI1) for Points Motors with Common Ground

48 SERIES Relay interface modules 10 A

ABB Drives. User s Manual HTL Encoder Interface FEN-31

NC-12 Modbus Application

Telephone- and leased line modem for industrial applications TD-36

Technical data. General specifications. Signal voltage V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.

Product Information. Gateway For Connecting EnDat Encoders to PROFIBUS-DP

Rack mounted telephone- and leased line modem for industrial applications

FN2001-A1 Network module (SAFEDLINK) Mounting Installation

IO-RM3 3-Stage Relay Module

Data Sheet. Adaptive Design ltd. Arduino Dual L6470 Stepper Motor Shield V th November L6470 Stepper Motor Shield

TX OPEN RS232/485 module

49 Series - Relay interface modules A. Features

HSP GmbH Zum Handwerkerhof Wendelstein Tel / Fax: / Web: HSP@hsshsp.de NTG-3000.

Contents. Document information

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2, /0.65/0.

Fieldbus slave modules with I/Os, DIO

Digital input modules

L5354 ControlNet Communications Interface

Combi switchbox with integrated 3/2 way pilot valve

Voltage Regulator SPAU 341 C. Product Guide

1 pole, 16 A Screw terminal connection 35 mm rail (EN 60715) mounting. 2 pole, 8 A Screw terminal connection 35 mm rail (EN 60715) mounting

38 Series - Relay interface modules A

Electric Rotary Actuator - On/Off or programmable control actuator

Power Supply and Indicator Unit Type Fig. 1 Type Mounting and Operating Instructions EB 9539 EN

Combi B Alarm box. Mounting instructions

80 Series - Modular timers 16 A. Features

HARTING econ 3000 Introduction and features

Practical steps for a successful. PROFIBUS Project. Presented by Dr. Xiu Ji Manchester Metropolitan University

mecotron Safety relay ESTOP-2 For emergency stop monitoring

Programmable Room Thermostat 7 Day (5-2 Day) Models: / Power Supply: Battery / Mains

Specifications for EM VDC 4 In/4 Out and EM VDC 4 In/4 Relay Out

38 Series - Relay interface modules A

PNOZsigma - Base units

SIMATIC. ET 200S distributed I/O Digital electronic module 8DO DC24V/0.5 A (6ES7132-4BF00-0AA0) Preface. Properties 1. Diagnostics 2.

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

T7560A,B,C Digital Wall Module

User Manual. Air-conditioner Controller SB-DN-HVAC (MAC01.331)

MINI MCR-SL-R-UI(-SP)

Whale 3. User Manual and Installation Guide. DC Servo drive. Contents. 1. Safety, policy and warranty Safety notes Policy Warranty.

RS - SPM. Serial parallel translator module

38 SERIES. Relay interface modules A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.

WEA-Base. User manual for load cell transmitters. UK WEA-Base User manual for load cell transmitters Version 3.2 UK

How To Power A Power Control On An Ip40 (Ipl) With A Power Supply (Iplug) With An Ip20 Controller (Iphones) With Power Control (Power Control) With No Antenna) With The Ip20 (Power)

Operation Manual. Plasma torch height controller. Model: Compact THC Controller 150

Operating instructions Diffuse reflection sensor. OJ50xx / / 2004

Safety technique. Emergency stop module BO 5988 safemaster

For UK only RXL39.1 and the applications package SP-03 are sold in the United Kingdom only.

HCR3.2/.. Chipcard reader HOTEL SOLUTION

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT Spur 2. Spur 1. Zone 1. Zone 0

DMX-RELAIS 2 INRUSH. User manual

CAUTION! THE 7I29 USES VOLTAGE AND POWER LEVELS THAT REPRESENT A HAZARD TO LIFE AND LIMB.

LG Air Conditioning Multi F(DX) Fault Codes Sheet. Multi Split Units

Operation and Installation Manual

E-STOP relays, safety gate monitors

PCAN-MicroMod Universal I/O Module with CAN Interface. User Manual. Document version ( )

Preset Counter signo 721

FIREDEX Conventional Fire Panels

CONFIGURABLE SAFETY RELAYS

PLUTO Safety-PLC. Manual Absolute Encoders

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in

CONFIGURABLE SAFETY RELAYS

OPERATING MANUAL. Table of contents. 2 Phase Stepping Motor Driver 2M542. Rev. A. Introduction page 2. Specifications page 2 Timing chart page 3

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

DMX2PWM 9 Channel Dimmer Setup Manual

Smart DeviceNet Remote I/O Terminals

RM4TG20 three-phase network control relay RM4-T - range V

ATL Fuel Level Sender Probes

Applied Electronics. Commercial Dimming System UPDATE NOTICE

TELIKOU Intercom System. MS-500(4+1 channel) Main Station Instruction Manual

CelluLine CGW-TS GSM Cellular Gateway. Installation and Programming Manual

Contactless Encoder RI360P0-QR24M0-INCRX2-H1181

Quick Connect. quick - simple - efficient.

Air damper actuators

Contact expansion modules

R22. K Control. Indoor Unit. Nomenclature. Compatibility PL H 3 G K H B. Unit style Heat Pump Horse Power

MULTIFUNCTION TIME RELAY CRM-93H

TELIKOU Intercom System. TM-200 Main Station. Instruction Manual

Belimo Gateway MP to Modbus RTU - UK24MOD

Proportional pressure regulators VPPE

MasterINTERFACE 39 Series - Relay interface modules

Documentation for. KL2602 and KL2622. Two-channel Relay Output Terminals for 230 V AC / 30 V DC. Version: 1.4 Date:

GSM HOME SECURITY SYSTEM

HARDWARE MANUAL. Ixx24-A 1/20. Val Controls A/S Limfjordsvej 3 DK-6715 Esbjerg N Tel vc@valcontrols.com

Options for ABB drives, converters and inverters. User s manual FDPI-02 diagnostics and panel interface

WD-AMX Water Detection Controllers

Inductive Proximity Sensors

SMS 4 / SMS 5 safety mat Product information

DALI RC BASIC SO. Control unit Operating instructions

instabus KNX / EIB System System E F G H

Control Devices Catalogue. Control Devices. Preferred and Standard Products

EXTERNAL DIMENSIONS AND PARTS

Transcription:

Data sheet GIOD.1 Input/output module with CAN bus ERP no.: 5204183 www.guentner.de

Page 2 / 10 Contents 1 GIOD.1... 3 1.1 Functional description...3 1.2 Connections... 5 1.3 Electrical properties of... 9 1.4 Installation / Operating conditions... 9 1.5 Dimensions / Weight... 10

Page 3 / 10 1 GIOD.1 1.1 Functional description The GIOD.1 is controlled via CAN by a Güntner controller. The GIOD.1 possesses 16 digital inputs with a rated voltage of 24V DC and 8 relay outputs. The bus address of the GIOD.1 (node ID) is set up using a rotary encoding switch. The address 0xF may not be used for this. To ensure the bus connection between the controller and one or more other units works correctly, bus termination must be activated at the beginning and end of the bus connection by setting the units DIP switches labelled Term. They must be placed in the ON position to activate the termination. Units that are in the middle of the bus and therefore permitted to transfer the bus signal may not have bus termination activated. The status of the inputs and outputs is indicated by LEDs on the front of the casing. A lit LED against the digital inputs signifies that the corresponding input is receiving a high signal. A lit LED against the relay outputs signifies that the closer contact is closed. A power LED signifies that the internal electronic components are receiving power. There is also a status display for the bus connection that involves two LEDs.

Page 4 / 10 Bus status LED On Flashing 50:50 Brief single flash Three flashes with error LED Alternate flashing with error LED Synchronous fast flashing with error LED Bus error LED Off On Brief single flash Double flashing Three flashes with the bus status LED Alternate flashing with the bus status LED Synchronous fast flashing with error LED Power LED On Off Digital input LED On Off Digital output LED On Off The GIOD.1 is in operation The GIOD.1 can be taken into operation The GIOD.1 is currently stopped The software is attempting to overrun the stack on the GIOD.1 A layer setting service is being performed on the GIOD.1 Reset to default has been selected on the rotary coding switch (setting F ) Unit is operating correctly There is a static fault on the CAN bus The warning limit has been reached in the CAN controller A fault was detected in the lifeguard, nodeguard or heartbeat The software is attempting to overrun the stack on the GIOD.1 A layer setting service is being performed on the GIOD.1 Reset to default has been selected on the rotary coding switch (setting F ) The internal electronics are receiving power The unit is not powered or is reverse-poled The digital input detects a High signal The digital input detects a Low signal The digital output is closed The digital output is open

Page 5 / 10 1.2 Connections Upper row of connections Name DI1 Digital input 1 DI2 Digital input 2 DI3 Digital input 3 TB1 DI4 Digital input 4 DI5 Digital input 5 DI6 Digital input 6 DI7 Digital input 7 DI8 Digital input 8 TB2 TB3 13 14 23 24 33 34 43 44 53 54 63 64 Relay contact 1 closer Relay contact 2 closer Relay contact 3 closer Relay contact 4 closer Relay contact 5 closer Relay contact 6 closer

Page 6 / 10 Upper row of connections Name 73 74 83 84 Relay contact 7 closer Relay contact 8 closer

Page 7 / 10 Lower row of connections TB4 Name CAN +24V +24V GND CH CAN bus plug including power supply External feed for power supply Contact ground for external power feed CAN high signal CL Node ID CAN low signal Rotary switch for setting the bus node address 0: Address 0 1: Address 1 - - E: Address 14 F: Reset CANopen parameters to their default values DI9 Digital input 9 DI10 Digital input 10 DI11 Digital input 11 TB5 DI12 Digital input 12 DI13 Digital input 13 DI14 Digital input 14 DI15 Digital input 15 DI16 Digital input 16 +24V TB6 +24V +24V GND GND Voltage +24V Ground

Page 8 / 10 Lower row of connections Name GND Term CAN DIP switch for CAN bus termination (120Ω) CAN bus plug including power supply

Page 9 / 10 1.3 Electrical properties of Min Type Max Unit Power supply DC 21 24 30 V Current consumption 100 250 ma Digital inputs High level 15 24 30 V Low level -3 0 5 V Relay outputs Power supply DC 24 30 V Voltage AC 250 V Current resistive load 24V DC/250V AC 1 A Current inductive load 24V DC/250V AC 1 A Switch cycles, mechanical 1*10 6 Switching cycles Switch cycles, electrical 1*10 5 Switching cycles CAN bus Dielectric strength -24 24 V Transmission rate 125 kbit/s 1.4 Installation / Operating conditions The module is designed for mounting on a top-hat rail. Bus lines that are not wired via the supplied ribbon cable must be shielded. The shielding of bus lines must be earthed at one end only. Suitable shielding and routing measures must be taken to ensure that mains cables and motor cables do not give rise to any interference in signal and control lines. Temperature: Storage location, Transport Operation: Protection rating: IP 20-20 C.. +70 C -20 C.. +65 C

Page 10 / 10 1.5 Dimensions / Weight You will find the casing dimensions below. All dimensions are given in millimetres. Dimensions of casing of GIOD.1 Weight: ca. 340g