OFF-LINE COMMUNICATIONS WITH CINCINNATI EQUIPMENT Pg. 1 of 5



Similar documents
USER GUIDE. Ethernet Configuration Guide (Lantronix) P/N: Rev 6

1. Make sure that no client accounts are open. 2. Click on Setup, then click Modem. The Modem Setup window will appear.

PC Program User s Guide ( ) 1. Connecting the PC. 2. Installation and Start-up. 3. Programming

DUKANE Intelligent Assembly Solutions

? Index. Introduction. 1 of 38 About the QMS Network Print Monitor for Windows NT

DIRECT INTERNET DATA. User s Guide

PARTNER ACS R4.0 Remote Administration R4.0. Getting Started

Accessing Diagnostics using a Dialup Modem

Programming and Using the Courier V.Everything Modem for Remote Operation of DDF6000

How to setup a serial Bluetooth adapter Master Guide

SUDT AccessPort TM Advanced Terminal / Monitor / Debugger Version 1.37 User Manual

LS-101 LAN to Serial Device server. User s Manual

IP SERIAL DEVICE SERVER

MFC7840W Windows Network Connection Repair Instructions

Wireless LAN g USB Adapter

SECURITY SYSTEM MANAGEMENT SOFTWARE FOR WINDOWS. Quick Start Instructions

GPS DATABASE LOADING TECH HELP

Smart Control Center. User Guide. 350 East Plumeria Drive San Jose, CA USA. November v1.0

How To Connect A Directsofl To A Powerpoint With An Acd With An Ctel With An Dm-Tel Modem On A Pc Or Ipad Or Ipa (Powerpoint) With A Powerline 2 (Powerline

CNC Transfer. Operating Manual

Setting up VPN Access for Remote Diagnostics Support

Intel Active Management Technology with System Defense Feature Quick Start Guide

RS-232 Communications Using BobCAD-CAM. RS-232 Introduction

LAN / WAN Connection Of Instruments with Serial Interface By Using a Terminal Server

How To Set Up A Modbus Cda On A Pc Or Maca (Powerline) With A Powerline (Powergen) And A Powergen (Powerbee) (Powernet) (Operating System) (Control Microsci

Centurion PLUS CPC4 Download Guide

isco Connecting Routers Back to Back Through the AUX P

Instructions on How to Use HyperTerminal to Test Serial Ports ...

CHARGE Anywhere. Mobile POS. User s Guide

Model 288B Charge Plate Graphing Software Operators Guide

Hypercom Key Loading and Management (HKLM) RS232 PPP Key Injection PC Setup Guide

User s Manual for Fingerprint Door Control Software

Honeywell Internet Connection Module

WHQL Certification Approval...2 User Interface...3 SUNIX s COMLab..4

ETHERNET WEATHER STATION CONNECTIONS Application Note 33

FINS Gateway For OMRON PLCs

PM1122 INT DIGITAL INTERFACE REMOTE

Global Monitoring + Support

PRILINK PRI Management System

GETTING STARTED WITH FLEXI-CLOUD

ECcom. Signal Monitor Communications Software Operations Manual

Data Retrieval. Chapter III. In This Chapter

PC Programming Manual KX-TA/TES/TEM824. Advanced Hybrid System. Model No.

Connecting and Setting Up Your Laptop Computer

TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL

Programming Flash Microcontrollers through the Controller Area Network (CAN) Interface

MS830 / MS833 Barcode Reader v1.0 9-December-2014

PRODUCTIVITY THROUGH INNOVATION 600 CONTROL DIRECT DRIVE TECHNICAL/OPERATION MANUAL

Crow Limited Warranty. Print Version 017

Andover Continuum Remote Communication Configuration Guide

Job Aid: Creating Additional Remote Access Logins

Modbus and ION Technology

Technical Note #14. Phone Modem Device Support. GE ED&C Home Search ED&C GE ED&C Power Management Home GE ED&C PMCS Home

ICS Technology. PADS Viewer Manual. ICS Technology Inc PO Box 4063 Middletown, NJ

File Transfers. Contents

PCMCIA 1 Port RS EDITION OCTOBER 1999

INSTALLATION AND OPERATION MANUAL CNFE2DOE TERMINAL SERVER

Virtual Office Remote Installation Guide

TestManager Administration Guide

Bluetooth Installation

SAPIP GUI INSTALLATION. Table of Contents

Using a Laptop Computer with a USB or Serial Port Adapter to Communicate With the Eagle System

TRP-C31M MODBUS TCP to RTU/ASCII Gateway

UPS Network Interface. Quick InstallationGuide

SNMP-1 Configuration Guide

HYDROSOFT Version INSTALLATION AND OPERATING

TOSHIBA GA Printing from Windows

RS232 Programming and Troubleshooting Guide for Turbo Controls

Vicon Flash Upgrade Software

F2103 GPRS DTU USER MANUAL

AutoWAVE. Programming Instructions P/N Part of Thermo Fisher Scientific. Revision D

TAS-2000 Series. MSW-003 Software. User Guide. LT-880 Rev. 1 September 2004

Prisma II Software Upgrade Program (SOUP) Installation Guide


Virtual Integrated Design Getting started with RS232 Hex Com Tool v6.0

TX3 Series TELEPHONE ACCESS SYSTEMS. Configurator Quick Start. Version 2.2 Mircom Copyright 2014 LT-973

Field Manager Mobile Worker User Guide for RIM BlackBerry 1

Iridium Extreme TM Satellite Phone. Data Services Manual

Centers for Medicare and Medicaid Services. Connect: Enterprise Secure Client (SFTP) Gentran. Internet Option Manual

Quick Note 32. Using Digi RealPort with a Digi TransPort Router. UK Support September 2012

Pendragon Forms Industrial

Getting Started with IntelleView POS Administrator Software

Remote Access Server - Dial-Out User s Guide

#65 4GHGTGPEG")WKFG #FXCPEGF"6GTOKPCN"5QHVYCTG 8GTUKQP"502 HQT"%QPVTQNNGT/#% Catalog # Rev.02

Installation and initial configuration of UI View32, with PMap Server 7 and Precision Mapping Streets and Traveler 8.0 on Microsoft Vista

Signature Center Getting Started Guide

ADDENDUM - Bluetooth interface Option Instructions for using Extech Printer with a Bluetooth device

Modbus Communications for PanelView Terminals

USB GSM 3G modem RMS-U-GSM-3G. Manual (PDF) Version 1.0,

DSX Master Communications

3.1 RS-232/422/485 Pinout:PORT1-4(RJ-45) RJ-45 RS-232 RS-422 RS-485 PIN1 TXD PIN2 RXD PIN3 GND PIN4 PIN5 T PIN6 T PIN7 R+ PIN8 R-

integration tools setup guide SIM 3 Remote Guide to controlling a SIM 3 Audio Analyzer remotely over a network connection from a laptop

Back-up Server DOC-OEMSPP-S/2014-BUS-EN-10/12/13

Communications Instructions for DOOSAN, FANUC Controls

User s Manual TCP/IP TO RS-232/422/485 CONVERTER. 1.1 Introduction. 1.2 Main features. Dynamic DNS

How to setup a serial Bluetooth adapter

Guide to Installing BBL Crystal MIND on Windows 7

RouteFinder SOHO. Quick Start Guide. SOHO Security Appliance. EDGE Models RF825-E, RF825-E-AP CDMA Models RF825-C-Nx, RF825-C-Nx-AP

Installation Notes for Outpost Network Security (ONS) version 3.2

ROYAL REGISTERLINK USER'S GUIDE

Transcription:

Pg. 1 of MACHINE TYPE BACKGROUND CAPABILITIES SOFTWARE NEEDED* C. I. SOFTWARE AVAILABLE Autoform - VMEI NO Kermit - Off-Line Programming - -D Programming Autoform - VMEII YES Kermit - Same as above - D Programming FMII - VMEI NO Kermit - Off-Line Programming FMII - VMEII YES Kermit - Off-Line Programming CBII YES Kermit None OBS New Style - June 1990 or later YES Kermit Off- Line Programming OBS Prior to June 1990 NO Customer Created Basic Program - Refer to EM-1 None FSUIII and CNC Shears NO Customer Created Basic Program - Refer to EM-0 None DGC and MAGC Shears YES Kermit None * If C. I. Software is purchased, Kermit Software is included. Since 1987 Kermit became the main communications protocol used for all flatroll equipment. Kermit is installed in all controls that were developed after that time. Kermit is a file transfer protocol in itself developed and maintained by Columbia University. Since this type is being used, it requires a version of the software to be installed in the computer to properly communicate with the other end. If a file server is all that is needed (saving files to a computer), then the Kermit software is all that will be required. This program can be obtained by either downloading from the following address; http://www.columbia.edu/kermit/mskermit.html or by contacting Columbia University direct at; Kermit Distribution Columbia University 61 W. 11th Street New York, NY 100 Since our controls are based on DOS type programs, the dos version Kermit.1 works well with windows9 and windowsnt systems.

Page of The following files are needed to set the parameters that Kermit will work with. They should be stored in the same directory that Kermit is in. Add these commands to the end of the.ini file noted. FILE FOR MSKERMIT.1 FILE FOR KERMIT 9 MSCUSTOM.INI K9CUSTOM.INI comment -- MSCUSTOM.INI kermit init file ; FILE K9CUSTOM.INI -- Kermit 9 Customizations set port 1 set baud 9600 set warning off set send timeout 8 set receive timeout 8 set retry 10 cwd (Type in directory that files will be stored to. (ex. c:/download)) CLS server (only use this line if the computer is going to be used as a server. i.e. all communications will be initiated from the control.) set line com set speed 9600 set retry 10 set send timeout set receive timeout set flow-control none set server display on cd (Type in directory that files will be stored to.( ex. (c:/download)) CLS set printer {PRN} server (only use this line if the computer is going to be used as a server. i.e. all communications will be initiated from the control.) Kermit.1 or.1 Note that the Columbia web site has downloads for both.1 and.1. You must first download and install.1. The.1 version listed on the site is an upgrade so it does not contain all the files. To upgrade download and copy the.1 files into your.1 directory. Be sure baud rates of both computer and control are the same. Typically they should be at 9600. To check the computer using kermit.1, at the kermit prompt type show status. This will show all the settings related to Kermit. Other commands are available and can be viewed by typing? at the prompt. A few commands that may be helpful are as follows; MS-Kermit> (see below) set debug on - This will display the packets being transferred in progress. log packets - This will create a file that can be viewed after the transfer has failed or completed. set????? - A different baud rate get??????? - A file from the control to the computer send?????? - A file from the computer to the control remote directory - Retrieves the active directory in the control - To change the directory in the control, type remote cwd?????? (ex. utool) server - Sets the computer to server mode. Communications/File transfers can only be iniated from the control. exit - Exits from the Kermit program

Page of Kermit 9 The newest version of Kermit which runs under Windows 9 and NT is called Kermit 9. They have enhanced this version to make it a Windows Console Application. It has a lot of new features for dialing up online services and accessing internet sites. Most of these features we do not need. This version is also no longer free. There is a minimal charge and it must be obtained directly from Columbia University. (http://www.columbia.edu/kermit) Note that the older MSKermit will still run under NT and 9. Starting the Application There are two ways to start up the application. The easiest way is to run the K9.EXE file. This will start the application and execute any commands the user has typed in the K9CUSTOM.INI file. Note the "set line" command should be changed to use the desired communication port, either com1 or com in most cases. If you get an error stating that No Carrier is detected when starting Kermit, add the following line to your.ini file set carrier OFF If you want to go directly into the SERVER mode automatically, then make "server" the last command in this file. Otherwise you can type the command "server" on the command line after the application starts. If you are not using it in server mode, commands such as SEND, RECEIVE, REM DIR and REM DEL can be used to transfer files to and from the machine control. The other way to start up the Kermit 9 application is to run the K9dial.EXE. This gives a more Windows like user interface to the configuration. Use the ADD button to enter a new configuration and set the Access Info type to Direct Serial under the General menu. Under the File Transfer menu set the Protocol to Kermit Robust, File transfer mode to Binary, File Collision Mode to Overwrite. Under the Communications menu, set the Line to the desired Comm Port and the Speed to the desired baud rate (9600). Set Flow control to NONE, Parity to None and Carrier Detection to Off. To start Kermit, then use the CONNECT button. Pressing ALT-X will bring up the command window where kermit commands may be typed. Long File Names Using Kermit 9 allows support for long filenames. It is now possible to store 16 character filenames directly to the PC. Before this was only possible when using our Autoform Offline Programming software as a file server. To make it easier to startup the Kermit application, you can create a shortcut icon to the K9.EXE application and add it to your Start menu or place it on your desktop. You can also add it to your Startup Items so the Kermit is started whenever the PC is powered up. Directories for storing files: By default K9 will store all files in the same directory the program is installed in, usually \K9. When using it with an Autoform, the user should enable the Remote Directory Change option on the Communications Setup Screen on the Autoform Control. They should also set up the names of the directories for the Remote Volume in the File Preferences screen. This way any file transfers will automatically change the directory to the correct one for a given file type such as PROGRAM or Upper Tool or Lower Tool etc. If you only want to store all files in one directory, you can add a CWD (Change Working Directory) command to the K9CUSTOM.INI file which sets the default directory.

Page of Troubleshooting: To troubleshoot your cable connection, use the Terminal Mode on the Autoform machine control. Type CONNECT at the Kermit command line. Any characters you type on the control should be displayed on the PC and vice versa. If you have communication in only one direction, then it is likely that you have the transmit and receive wires are reversed. In the case of the CBII which has no terminal mode, use the Communication diagnostic to send out the string of characters to the PORT which is the Kermit port. This string should be displayed on the PC in CONNECT mode. This diagnostic can also be used to test your cable by jumping the transmit and receive signals together. If you cannot get the PC to send any characters, then make sure that you have the Communication Ports enabled properly. This can be checked in the Ports Control Panel under NT and System/Devices Control Panel under 9/98. Most PC's now do not physically assign a comm port to a specific connector on the back of the PC. Make sure that the comm port you are connected to matches the comm Port which is assigned in the Ports Control Panel. Sometimes, newer PC's will have comm ports enabled or assigned using the BIOS. You can usually get into the BIOS configuration while powering up with the F1 function key held down. Once common source of conflict is an INTERNAL MODEM configured to use the same comm. port. Check the Modems control panel and see which comm. port it is using. It may be using com1 internally and thus the com1 connector on the back of the PC cannot be used simultaneously. In this case either remove the internal modem or configure it to use another available com address such as com. The modems control panel should be changed to specify a direct Serial connection on the specific comm. port being used. There can also be conflicts with other applications trying to use the same comm. Port. For example, in one case the Hotsync application which allowed a Palm Pilot to upload/download data automatically was constantly monitoring the comm. Port and this interfered with Kermit trying to use it. The solution in this case was to configure the Hotsync application for manual instead of automatic operation. I recently found a difference between Kermit 9 and MSKermit. If you wire your cable on the PC side without the hardware handshake pins jumpered together, MSKermit doesn't care. However, Kermit 9 defaults to Hardware Handshaking and will refuse to send anything out unless you add a "SET flow-control NONE" command to the initialization file.

Page of RS Communications Manuals are available upon request from Cincinnati Incorporated for most machine types. A typical 9 pin to 9 pin connection is as follows. Depending on your system, if this set-up doesn't work, try swapping pins and on the computer end. To AF, PM S Port 6 To DGC & CBII J9 Port 1 To VMEII Gages Monitor Port & FMII S Port 1