SIMATIC. ET 200S distributed I/O Digital electronic module 8DI DC24V (6ES7131-4BF00-0AA0) Preface. Properties 1. Diagnostics 2.



Similar documents
SIMATIC. ET 200S distributed I/O Digital electronic module 8DO DC24V/0.5 A (6ES7132-4BF00-0AA0) Preface. Properties 1. Diagnostics 2.

SIMATIC. ET 200S distributed I/O 2AO I ST analog electronic module (6ES7135-4GB01-0AB0) Preface. Properties 1. Parameters 2.

SIMATIC. ET 200S distributed I/O 2AI U ST analog electronic module (6ES7134-4FB01-0AB0) Preface. Properties 1. Parameters 2.

CPU PN/DP: Configuring an ET. 200S as PROFINET IO device SIMATIC. PROFINET CPU PN/DP: Configuring an ET 200S as PROFINET IO device

SIMATIC S Getting Started for First Time Users. Order No.: 6ZB5310-0NC02-0BA0 04/2007 A5E

Validity 1. Improvements in STEP 7 2. Improvements in WinCC 3 SIMATIC. Readme. Programming and Operating Manual

DI 16x24VDC HF Digital Input Module (6ES7521-1BH00-0AB0) SIMATIC. S7-1500/ET 200MP DI 16x24VDC HF Digital Input Module (6ES7521-1BH00-0AB0) Preface

Validity 1. Installation 2 SIMATIC. WinCC flexible Tag simulator Update 1. Readme

DANGER indicates that death or severe personal injury will result if proper precautions are not taken.

Creating the project and hardware. TIA Portal. SIMATIC Creating the project and hardware. Introduction to the TIA Portal 1. Creating a project

SIMATIC. S7 300 PLC CPU 317T-2 DP: Controlling a virtual axis. Introduction. Preparation. Learning units 3. Further information 4.

DANGER indicates that death or severe personal injury will result if proper precautions are not taken.

SIMATIC NET. CP AS-Interface Master B C. Preface Contents. Technical Description and Installation Instructions Interface to the User Program

Modular I/O System Analog and Digital Interface Modules

Documentation for. KL2602 and KL2622. Two-channel Relay Output Terminals for 230 V AC / 30 V DC. Version: 1.4 Date:

SIMATIC HMI. WinCC flexible 2008 Getting Started - First-Time Users Getting Started. Printout of the Online Help 06/2008 A5E

SIMATIC. WinCC V7.0. Getting started. Getting started. Welcome 2. Icons 3. Creating a project 4. Configure communication 5

Specifications for EM VDC 4 In/4 Out and EM VDC 4 In/4 Relay Out

Creating the program. TIA Portal. SIMATIC Creating the program. Loading the block library. Deleting program block Main [OB1] Copying program blocks

SIMATIC. PC Adapter USB. Preface, Contents Properties of the PC Adapter USB 1. Package Components

SIMATIC. ET 200S distributed I/O IM151-1 STANDARD interface module (6ES7151-1AA05-0AB0) Preface. Properties 1. Parameters 2.

SIMATIC. SIMATIC Logon. User management and electronic signatures. Hardware and Software Requirements. Scope of delivery 3.

Fieldbus slave modules with I/Os, DIO

Configuration limits for products of the SIMATIC NET PC Software V12 SIMATIC NET. Configuration limits for products of the SIMATIC NET PC Software V12

Short-circuit current rating (SCCR) of. industrial control panels. NEC Article 409 and UL 508A

SIMATIC. Open TCP/IP Communication via Industrial Ethernet. Contents Open TCP/IP Communication via Industrial Ethernet 1. Index.

Visualization SIMATIC. Visualization. Present sample project. HMI configuration. Insert HMI device from libraries 3. Configuring HMI connection 4

CompactLogix Power Supplies Specifications

SINAMICS drives SINAMICS DCM. DC converters from 6 kw to 2500 kw for variable-speed direct-current drives. Load-balanced control application

S7-400H SIMATIC. Fault-tolerant systems S7-400H. Preface 1 Fault-tolerant automation systems. S7-400H setup options 3.

SIMATIC NET. Functions (FC) and function blocks (FB) for SIMATIC NET S7 CPs. Preface. Overview and general information on working with FCs and FBs

SIMATIC. Process Control System PCS 7 Configuration Symantec Endpoint Protection (V12.1) Preface 1. Virus scanner administration 2.

Patch management and security. updates SIMATIC. Process Control System PCS 7 Patch management and security updates. Preface 1

What ensures easy and fast wiring?

2 Counter Module SIMATIC. S7-300 FM Counter module. Preface. Product Overview. How the FM Counts 2. Installing and Removing the FM 350-

WinCC Runtime Professional Readme SIMATIC HMI. WinCC V11 SP1. Readme WinCC Runtime Professional. Special considerations for Windows 7.

Brake module AX5021. Documentation. Please read this document carefully before installing and commissioning the brake module!

SIMATIC. S7-300 and M7-300 Programmable Controllers Module Specifications. Preface, Contents. General Technical Specifications. Power Supply Modules

Validity 1. Improvements in STEP 7 2. Improvements in WinCC 3. Simatic. Readme. Readme

SIMATIC. SM 335 High-Speed Analog Input/Output Module for the SIMATIC S7-300

Information Server Documentation SIMATIC. Information Server V8.0 Update 1 Information Server Documentation. Introduction 1. Web application basics 2

6ES7314-6CG03-0AB0. Supply voltages Rated value 24 V DC Yes permissible range, upper limit (DC) circuit breaker type B, min. 4 A

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

LOGO! LOGO! App V.10. LOGO! app 1. Making basic settings and establishing a connection to LOGO! Using the device overview 3. Creating controls 4

Part 1: User information SIMATIC ET 200B Distributed I/O Station Manual Part 2: Reference information Appendices EWA 4NEB c Edition 04

SIMATIC NET Industrial Ethernet switches MM900 media modules for SCALANCE XR-500M

ADM1TE 5/30A DIN rail single phase two wire energy meter

PROFINET CPU 314C-2 PN/DP, PN/DP, PN/DP, PN/DP: Configuring the PROFINET interface

EE-SPY801/802. Photomicrosensors for detecting wafer-carrier mounting. Wafer-carrier Mounting Photomicrosensors. Ordering Information.

DRM75A 230V 20/100A DIN rail single phase two wire energy meter

IBS IP KIS A. Data Sheet INTERBUS-S. Digital I/O Module

ZC-24DO CANopen I/O Module: 24 Digital Outputs

Automation Unit TM 1703 ACP Flexible automation and telecontrol

3500/62 Process Variable Monitor

Digital input modules

Performing an automated installation

Installation guide H A. HSI hardwired system interface

Siemens AG Fieldbus solutions with the SIMATIC PCS 7 distributed control system. Brochure April 2010 SIMATIC PCS 7. Answers for industry.

Cross-beam scanning system to detect slim objects. 100 mm in

PCS0100en Persy Control Services B.V. Netherlands

SIMATIC NET. AS-Interface - Introduction and Basics A B. Preface, Contents

6ES7313-5BF03-0AB0. Supply voltages Rated value 24 V DC Yes permissible range, upper limit (DC) circuit breaker type B, min. 4 A

Operating Instructions (Compact) Edition 02/2006

ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01

COMOS. Lifecycle COMOS Snapshots. "COMOS Snapshots" at a glance 1. System requirements for installing "COMOS Snapshots" Database management 3

SIMATIC. Automation System S7-400 Hardware and Installation A B. Preface, Contents. Product Overview. Installing the S Addressing the S7-400

Tina 2A/B Adaptor unit

Training Document for Comprehensive Automation Solutions Totally Integrated Automation (T I A) MODUL E04

S SIMATIC S Welcome. Automation task. Hardware section 2. Software section 3. Security. Getting Started 05/2014 A5E AC

Industrial Communication

User Manual Revision English

Contents. Document information

Safety technique. Emergency stop module BO 5988 safemaster

Original instructions Tina 3A/Aps Adaptor unit

Service & Support. Higher-level safe switch-off of the power supply of functionally nonsafe standard modules? Wiring Examples.

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

SIMATIC. S7-300 Programmable Controller Installation and Hardware. Preface, Contents. Product Overview 1. Mechanical Configuration 2

Model 1756 Test Lead Kit

Automation License Manager

EPM3. Phase Sequence and Motor Rotation Tester. Users Manual

The CP FO provides access to different communication services of the PROFIBUS bus system:

Permissible ambient temperature Operation Storage, transport

Addendum to the Operating Instructions

CQM1-SF200/CS1W-SF200

Product Information. Gateway For Connecting EnDat Encoders to PROFIBUS-DP

4 non-safe digital I/O channels 2 IO-Link Master V1.1 slots. Figure 1. Figure 2. Type code. TBPN-L1-FDIO1-2IOL Ident no

DB Administration COMOS. Platform DB Administration. Trademarks 1. Prerequisites. MS SQL Server 2005/ Oracle. Operating Manual 09/2011

MINI MCR-SL-R-UI(-SP)

DANGER indicates that death or severe personal injury will result if proper precautions are not taken.

User Manual Revision English

SITOP UPS1600 / UPS1100. SITOP power supply SITOP UPS1600 / UPS1100. Overview. Safety information. Description, device design, dimension drawing 2

CP Page 1342 Mar 2008 Siemens ITS

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

DVPPF02-H2. PROFIBUS DP Slave Communication Module Application Manual

CPUs - CPU PN/DP

SIMATIC HMI. WinCC flexible Getting Started First Time User. Order number 6ZB5370-1CL02-0BA2. Edition 04/2006 A5E

The CP provides access to different communication services of the PROFIBUS bus system:

5SV Residual Current Protective Devices

Transcription:

SIMATIC ET 200S distributed I/O SIMATIC Preface Properties 1 Diagnostics 2 ET 200S distributed I/O Digital electronic module 8DI DC24V (6ES7131-4BF00-0AA0) Manual 04/2007 A5E01077339-01

Safety Guidelines Safety Guidelines This manual contains notices you have to observe in order to ensure your personal safety, as well as to prevent damage to property. The notices referring to your personal safety are highlighted in the manual by a safety alert symbol, notices referring only to property damage have no safety alert symbol. These notices shown below are graded according to the degree of danger. DANGER indicates that death or severe personal injury will result if proper precautions are not taken. WARNING indicates that death or severe personal injury may result if proper precautions are not taken. CAUTION with a safety alert symbol, indicates that minor personal injury can result if proper precautions are not taken. CAUTION without a safety alert symbol, indicates that property damage can result if proper precautions are not taken. NOTICE Qualified Personnel Prescribed Usage Trademarks indicates that an unintended result or situation can occur if the corresponding information is not taken into account. If more than one degree of danger is present, the warning notice representing the highest degree of danger will be used. A notice warning of injury to persons with a safety alert symbol may also include a warning relating to property damage. The device/system may only be set up and used in conjunction with this documentation. Commissioning and operation of a device/system may only be performed by qualified personnel. Within the context of the safety notes in this documentation qualified persons are defined as persons who are authorized to commission, ground and label devices, systems and circuits in accordance with established safety practices and standards. Note the following: Disclaimer of Liability WARNING This device may only be used for the applications described in the catalog or the technical description and only in connection with devices or components from other manufacturers which have been approved or recommended by Siemens. Correct, reliable operation of the product requires proper transport, storage, positioning and assembly as well as careful operation and maintenance. All names identified by are registered trademarks of the Siemens AG. The remaining trademarks in this publication may be trademarks whose use by third parties for their own purposes could violate the rights of the owner. We have reviewed the contents of this publication to ensure consistency with the hardware and software described. Since variance cannot be precluded entirely, we cannot guarantee full consistency. However, the information in this publication is reviewed regularly and any necessary corrections are included in subsequent editions. Siemens AG Automation and Drives Postfach 48 48 90327 NÜRNBERG GERMANY Ordernumber: A5E01077339-01 P 12/2007 Copyright Siemens AG 2007. Technical data subject to change

Preface Preface Purpose of the manual This manual supplements the ET 200S Distributed I/O System Operating Instructions. General functions for the ET 200S are described in the ET 200S Distributed I/O System Operating Instructions. The information in this document along with the operating instructions enables you to commission the ET 200S. Basic knowledge requirements To understand these operating instructions you should have general knowledge of automation engineering. Scope of the manual This manual applies to this ET 200S module. It describes the components that are valid at the time of publication. Recycling and disposal Thanks to the fact that it is low in contaminants, this ET 200S module is recyclable. For environmentally compliant recycling and disposal of your electronic waste, please contact a company certified for the disposal of electronic waste. Additional support If you have any questions relating to the products described in these operating instructions, and do not find the answers in this document, please contact your local Siemens representative. http://www.siemens.com/automation/partner The portal to our technical documentation for the various SIMATIC products and systems is available at: http://www.siemens.com/automation/simatic/portal The online catalog and ordering system are available at: http://www.siemens.com/automation/mall Manual, 04/2007, A5E01077339-01 3

Preface Training center We offer courses to help you get started with the ET 200S and the SIMATIC S7 automation system. Please contact your regional training center or the central training center in D -90327, Nuremberg, Germany. Phone: +49 (911) 895-3200. http://www.siemens.com/sitrain Technical Support You can reach technical support for all A&D projects using the support request web form: http://www.siemens.com/automation/support-request Phone: + 49 180 5050 222 Fax: + 49 180 5050 223 For more information about our technical support, refer to our Web site at http://www.siemens.de/automation/service Service & Support on the Internet In addition to our documentation services, you can also make use of our comprehensive online knowledge base on the Internet. http://www.siemens.com/automation/service&support There you will find: Our Newsletter, which constantly provides you with the latest information about your products. The right documentation for you using our Service & Support search engine. The bulletin board, a worldwide knowledge exchange for users and experts. Your local contact for Automation & Drives in our contact database. Information about on-site services, repairs, spare parts. Lots more can be found on our "Services" pages. 4 Manual, 04/2007, A5E01077339-01

Table of contents Preface... 3 1 Properties... 7 1.1...7 2 Diagnostics... 13 2.1 Diagnostics using LED display...13 Index... 15 Manual, 04/2007, A5E01077339-01 5

Table of contents 6 Manual, 04/2007, A5E01077339-01

Properties 1 1.1 Properties Digital electronic module with eight inputs Nominal input voltage 24 VDC Suitable for connecting 2-wire sensors Supports isochronous operation Requirements for operation It is possible to operate the 8DI DC24V digital electronic module using the following interface modules with the order numbers specified (or higher). The interface modules listed in the table are not subject to any constraints. Interface module Order number (or higher) Firmware version (or higher) IM 151-1 STANDARD 6ES7151-1AA03-0AB0 --- IM 151-1 FO STANDARD 6ES7151-1AB02-0AB0 --- IM 151-1 HIGH FEATURE 6ES7151-1BA01-0AB0 V2.1.3 IM 151-3 PN IM 151-3 PN HIGH FEATURE IM 151-3 PN FO 6ES7151-3AA20-0AB0 6ES7151-3BA20-0AB0 6ES7151-3BB21-0AB0 V4.0.1 General terminal assignment Note Terminals A4, A8, A3 and A7 are only available at specified terminal modules. Manual, 04/2007, A5E01077339-01 7

Properties 1.1 Terminal assignment for 8DI DC24V (6ES7131-4BF00-0AA0) Terminal Assignment Terminal Assignment Notes 1 DI0 5 DI1 2 DI2 6 DI3 3 DI4 7 DI5 DIn: Input signal, Channel n AUX1: Sensor power supply 24 VDC (for example from power module) or potential bus (can be used freely up to 230 VAC) 4 DI6 8 DI7 A4 AUX1 A8 AUX1 A3 AUX1 A7 AUX1 Usable terminal modules Usable terminal modules for 8DI DC24V (6ES7131-4BF00-0AA0) TM-E15C26-A1 (6ES7193-4CA50-0AA0) TM-E15S26-A1 (6ES7193-4CA40-0AA0) TM-E15N26-A1 (6ES7193-4CA80-0AA0) TM-E15C24-01 (6ES7193-4CB30-0AA0) TM-E15S24-01 (6ES7193-4CB20-0AA0) TM-E15N24-01 (6ES7193-4CB70-0AA0) Spring terminal Screw-type terminal Fast Connect 8 Manual, 04/2007, A5E01077339-01

Properties 1.1 Manual, 04/2007, A5E01077339-01 9 Two-wire connection The following configuration example shows a two-wire connection with the electronic modules 8DI DC24V. You require further terminals so that sufficient terminals are available for the 24 VDC sensor power supply when the TM-E15S26-A1 terminal modules are used. In the example this is implement by the add-on terminal TE-U120S4x10. Per add-on terminal, terminal modules of the same height must exist across a minimum width of 120 mm. You can naturally also use other terminals for this configuration (for example, ET 200S potential distribution module 4POTDIS). 3 4 2 1 5 6 1 Terminal module TM-P15S23-A0 2 Power module PM-E 24 VDC 3 Electronic modules 8DI DC24V 4 Terminal modules TM-E15S26-A1 5 Sensor in 2-wire connection 6 Add-on terminal TE-U120S4x10

Properties 1.1 Block diagram Figure 1-1 Block diagram of the 8DI DC24V Technical Specifications 8DI DC24V (6ES7131-4BF00-0AA0) Dimensions and weight Width (mm) 15 Weight Approx. 35 g Module-specific data Supports isochronous operation Yes Number of inputs 8 Length of cable Unshielded max. 600 m Shielded Max. 1,000 m Parameter length 3 bytes Address space 1 byte 10 Manual, 04/2007, A5E01077339-01

Properties 1.1 Voltages, currents, potentials Rated supply voltage (from the power module) 24 VDC Reverse polarity protection Yes Electrical isolation Between the channels No Between the channels and backplane bus Yes Permissible potential difference Between the different circuits 75 VDC / 60 VAC Insulation test voltage 500 VDC Current consumption From supply voltage Dependent on the sensor Power dissipation of the module Typically 1.2 W Status, interrupts, diagnostics Status display Green LED per channel Diagnostics function No Data for selecting a sensor Input voltage Rated value 24 VDC For signal "1" 15 V to 30 V For signal "0" -30 V to 5 V Input current At signal "1" Typ. 7 ma (for 24 V) Input delay At "0" to "1" Typ. 3 ms (2.0 to 4.5 ms) At "1" to "0" Typ. 3 ms (2.0 to 4.5 ms) Input characteristic curve According to IEC 61131, Type 1 Connection of 2-wire BEROs Supported Permitted bias current Max. 1.5 ma Manual, 04/2007, A5E01077339-01 11

Properties 1.1 12 Manual, 04/2007, A5E01077339-01

Diagnostics 2 2.1 Diagnostics using LED display LED display 1 1 Status display for input status (green) Status and error displays Event (LEDs) Cause Remedy 1 5 2 6 3 7 4 8 On Input on channel 0 activated. On Input on channel 1 activated. On Input on channel 2 activated. On Input on channel 3 activated. On Input on channel 4 activated. On Input on channel 5 activated. On Input on channel 6 activated. On Input on channel 7 activated. Manual, 04/2007, A5E01077339-01 13

Diagnostics 2.1 Diagnostics using LED display 14 Manual, 04/2007, A5E01077339-01

Index B Basic knowledge requirements, 3 Block diagram, 10 D Disposal, 3 I Internet Service & Support, 4 L LED display, 13 R Recycling, 3 S Scope Manual, 3 Service & Support, 4 T Technical data, 10 Technical Support, 4 Terminal assignment, 7 Training center, 4 P Properties, 7 Manual, 04/2007, A5E01077339-01 15

Index 16 Manual, 04/2007, A5E01077339-01