Methylation Analysis Using Methylation-Sensitive HRM and DNA Sequencing



Similar documents
Introduction To Real Time Quantitative PCR (qpcr)

Real-time PCR: Understanding C t

Factors Influencing Multiplex Real-Time PCR

360 Master Mix. , and a supplementary 360 GC Enhancer.

Sequencing Guidelines Adapted from ABI BigDye Terminator v3.1 Cycle Sequencing Kit and Roswell Park Cancer Institute Core Laboratory website

Accurate and sensitive mutation detection and quantitation using TaqMan Mutation Detection Assays for disease research

BacReady TM Multiplex PCR System

Essentials of Real Time PCR. About Sequence Detection Chemistries

ZR DNA Sequencing Clean-up Kit

Real-Time PCR Vs. Traditional PCR

GenScript BloodReady TM Multiplex PCR System

DNA Integrity Number (DIN) For the Assessment of Genomic DNA Samples in Real-Time Quantitative PCR (qpcr) Experiments

Troubleshooting Sequencing Data

PrimeSTAR HS DNA Polymerase

Quantifiler Human DNA Quantification Kit Quantifiler Y Human Male DNA Quantification Kit

ZR-96 DNA Sequencing Clean-up Kit Catalog Nos. D4052 & D4053

Highly specific and sensitive quantitation

LightCycler 480 Real-Time PCR System. High Resolution Melting: Optimization Strategies. Technical Note No. 1

SEQUENCING. From Sample to Sequence-Ready

Advances in RainDance Sequence Enrichment Technology and Applications in Cancer Research. March 17, 2011 Rendez-Vous Séquençage

Single-Cell Whole Genome Sequencing on the C1 System: a Performance Evaluation

Validating Microarray Data Using RT 2 Real-Time PCR Products

DNA Sequence Analysis

Gene Expression Assays

MystiCq microrna cdna Synthesis Mix Catalog Number MIRRT Storage Temperature 20 C

Application Guide... 2

Development of a Workflow to Detect Sequence Variants in the BRCA1 and BRCA2 Genes

Path-ID Multiplex One-Step RT-PCR Kit

Protocol. Introduction to TaqMan and SYBR Green Chemistries for Real-Time PCR

PicoMaxx High Fidelity PCR System

Illumina Sequencing Technology

Procedures For DNA Sequencing

SYBR Green Realtime PCR Master Mix -Plus-

ab Hi-Fi cdna Synthesis Kit

Welcome to Pacific Biosciences' Introduction to SMRTbell Template Preparation.

Introduction To Epigenetic Regulation: How Can The Epigenomics Core Services Help Your Research? Maria (Ken) Figueroa, M.D. Core Scientific Director

High-quality genomic DNA isolation and sensitive mutation analysis

Data Analysis for Ion Torrent Sequencing

Stratagene QPCR Mouse Reference Total RNA

2.500 Threshold e Threshold. Exponential phase. Cycle Number

ID kit. imegen Anchovies II. and E. japonicus) DNA detection by. User manual. Anchovies species (E. encrasicolus. sequencing.

Co Extra (GM and non GM supply chains: Their CO EXistence and TRAceability) Outcomes of Co Extra

A Guide to High Resolution Melting (HRM) Analysis

Technical Note. Roche Applied Science. No. LC 18/2004. Assay Formats for Use in Real-Time PCR

HiPer RT-PCR Teaching Kit

Introduction. Preparation of Template DNA

Whole genome Bisulfite Sequencing for Methylation Analysis Preparing Samples for the Illumina Sequencing Platform

Forensic DNA Testing Terminology

Data Analysis on the ABI PRISM 7700 Sequence Detection System: Setting Baselines and Thresholds. Overview. Data Analysis Tutorial

VLLM0421c Medical Microbiology I, practical sessions. Protocol to topic J10

EZ DNA Methylation-Lightning Kit Catalog Nos. D5030 & D5031

DNA FRAGMENT ANALYSIS by Capillary Electrophoresis

Reduced Representation Bisulfite Sequencing for Methylation Analysis Preparing Samples for the Illumina Sequencing Platform

Beginner s Guide to Real-Time PCR

The Techniques of Molecular Biology: Forensic DNA Fingerprinting

TaqMan Fast Advanced Master Mix. Protocol

LightCycler 480 Real-Time PCR System

Table of Contents. I. Description II. Kit Components III. Storage IV. 1st Strand cdna Synthesis Reaction... 3

Go where the biology takes you. Genome Analyzer IIx Genome Analyzer IIe

QPCR Applications using Stratagene s Mx Real-Time PCR Platform

CompleteⅡ 1st strand cdna Synthesis Kit

Technical Manual No Update Date

Automation in genomics High-throughput management of biological samples and nucleic acids. Valentina Gualdi Operational Scientist PGP

REAL TIME PCR USING SYBR GREEN

AxyPrep TM Mag PCR Clean-up Protocol

Real time and Quantitative (RTAQ) PCR. so I have an outlier and I want to see if it really is changed

Intended Use: The kit is designed to detect the 5 different mutations found in Asian population using seven different primers.

BaculoDirect Baculovirus Expression System Free your hands with the BaculoDirect Baculovirus Expression System

quantitative real-time PCR, grain, simplex DNA extraction: PGS0426 RT-PCR: PGS0494 & PGS0476

The Power of Next-Generation Sequencing in Your Hands On the Path towards Diagnostics

DNA Sequencing Handbook

PATHOGEN DETECTION SYSTEMS BY REAL TIME PCR. Results Interpretation Guide

Sequencing Library qpcr Quantification Guide

GENOTYPING ASSAYS AT ZIRC

Recombinant DNA & Genetic Engineering. Tools for Genetic Manipulation

Thermo Scientific DyNAmo cdna Synthesis Kit for qrt-pcr Technical Manual

Improved methods for site-directed mutagenesis using Gibson Assembly TM Master Mix

DNA Sequencing Setup and Troubleshooting

RT-PCR: Two-Step Protocol

Objectives: Vocabulary:

Definition of Minimum Performance Requirements for Analytical Methods of GMO Testing European Network of GMO Laboratories (ENGL)

PrimePCR Assay Validation Report

Quantitative 1-Schritt-DNA-Methylierungsanalyse aus genomischer DNA

A Fast, Accurate, and Automated Workflow for Multi Locus Sequence Typing of Bacterial Isolates

amplification tech A Practical Guide to High Resolution Melt Analysis Genotyping

Single-Cell DNA Sequencing with the C 1. Single-Cell Auto Prep System. Reveal hidden populations and genetic diversity within complex samples

Getting Started Guide

Terra PCR Direct Polymerase Mix User Manual

Gene Expression Assay Performance Guaranteed With the TaqMan Assays QPCR Guarantee Program

Dye-Blob message: Example: Generally, this is due to incomplete excess dye removal of the cycle sequence reaction.

INSTRUCTION MANUAL. EZ DNA Methylation Kit Catalog Nos. D5001 & D5002. Highlights. Contents

The GeneAmp PCR System Results you can trust. A PCR platform you can grow with. GeneAmp. PCR System 9700

DNA and Forensic Science

Oncology Insights Enabled by Knowledge Base-Guided Panel Design and the Seamless Workflow of the GeneReader NGS System

Artisan Scientific is You~ Source for: Quality New and Certified-Used/Pre:-awned ECJuiflment

ABSTRACT. Promega Corporation, Updated September Campbell-Staton, S.

Mir-X mirna First-Strand Synthesis Kit User Manual

Troubleshooting for PCR and multiplex PCR

Real-time quantitative RT -PCR (Taqman)

Fast PCR: General Considerations for Minimizing Run Times and Maximizing Throughput

Transcription:

APPLICATION NOTE Methylation Analysis Using Methylation-Sensitive HRM and DNA Sequencing Methylation Analysis Using Methylation Sensitive HRM and DNA Sequencing Abstract DNA methylation is a key epigenetic mechanism that regulates gene expression and chromatin structure. This application note describes a workflow for analysis of DNA methylation in specific loci by methylationsensitive high-resolution melting (MS-HRM) followed by DNA sequencing of the reaction products (Figure 1). The workflow relies on Applied Biosystems real-time PCR and capillary electrophoresis instruments and is supported by a comprehensive set of reagents and software tools. MS HRM followed by Sanger-based DNA sequencing is a fast, simple method for methylation studies that can be manipulated to provide sensivity for methylation levels as low as.1 2%. Procedure Overview MS-HRM analysis offers a simple method for quickly analyzing the methylation status of specific genetic loci. Reaction products that merit further analysis can then be sequenced directly to identify precise methylation patterns. Genomic DNA is treated with bisulfite to convert unmethylated cytosines to uracil, then PCR primers are designed to amplify the region of interest, and the melting profiles of PCR products from the sample DNA are compared to those from fully methylated and unmethylated reference samples. PCR primers and amplicons are designed to provide the level of sensitivity required for the biological question of interest. Samples that are found to warrant further study are sequenced to identify precise methylation patterns. Applied Biosystems provides an integrated set of tools for locus-specific DNA methylation analysis using this optimized, streamlined procedure. The procedure is described in a general way in this application note. For detailed instructions, see the High Resolution Melting Getting Started Guide (P/N 43932) and the BigDye Terminator v1.1 Cycle Sequencing Kit Protocol (P/N 433736). Step 1: Bisulfite Conversion of DNA The first step of the workflow is to treat genomic DNA with bisulfite, which deaminates unmethylated cytosines (C) to form uracil (U), but does not affect methylated cytosines. Thus, bisulfite conversion changes the DNA sequence based on the methylation status of individual nucleotides in genomic DNA, and these changes can be detected via HRM analysis [1]. The Applied Biosystems methylseqr Bisulfite Conversion Kit permits complete conversion of unmethylated cytosine to uracil in reactions that minimize DNA damage and maximize unbiased recovery of DNA. Step 2: Primer Design PCR primer design for MS-HRM is critical the free online tool from Applied Biosystems, Methyl Primer Express Software v1., was developed specifically for primer design in methylation studies (www.appliedbiosystems.com/methylprimerexpress). We recommend designing several sets of PCR primers for each genomic DNA region of interest, testing them for specificity and the ability to discriminate methylated from unmethylated DNA, and selecting the best-performing assay(s) for analysis of experimental samples. There are three main criteria to consider in designing 1 Bisulfite Conversion of DNA 2 Primer Design 3 High-Resolution Melting Optimization 4 Establishing MS-HRM Standard Curves and Sample Analysis 5 Sequencing HRM Product methylseqr Bisulfite Conversion Kit Methyl Primer Express Software MeltDoctor HRM reagents ViiA 7 Real-Time PCR System 79HT Fast Real-Time PCR System 75 Fast Real-Time PCR System StepOnePlus Real-Time PCR System StepOne Real-Time PCR System ViiA 7 Software HRM Module High Resolution Melt Software v2. High Resolution Melt Software v3. Veriti 96-Well Fast Thermal Cycler 31 Genetic Analyzer BigDye Terminator v1.1 Cycle Sequencing Kit BigDye XTerminator Purification Kit Figure 1. Applied Biosystems Workflow for Methylation-Sensitive High-Resolution Melting (MS-HRM) Analysis Followed by DNA Sequencing.

methylseqr Bisulfite Conversion Kit The Applied Biosystems methylseqr Bisulfite Conversion Kit is a robust method for generating high-quality bisulfite-converted DNA for optimized methylation analysis. The kit uses size exclusion column purification to increase sample yields and reduce the amount of bias seen with resin purification methods. PCR primers: amplicon length, number of potential methylation sites in the amplicon, and inclusion of CpG dinucleotides in the PCR primer sequence. All of these factors can have a big influence on the sensitivity of the assay, and in some cases they can be manipulated to discriminate large or small differences in methylation states. Amplicon Length and Number of Methylation Sites The greater the number of potential methylation sites in an amplicon, the larger the T m difference between PCR products from highly methylated and unmethylated DNA samples. This makes it easy to distinguish melt profiles; however, it may also contribute to PCR bias. Including too few CpG dinucleotides, on the other hand, may produce melt profiles that are too similar to be useful for methylation analysis. PCR bias is based on the observation that, in general, DNA fragments with high C content are not amplified as efficiently as fragments with high U/T content. After bisulfite conversion, unmethylated stretches of DNA will be significantly enriched for U/T nucleotides and may be amplified to the exclusion of their methylated counterparts [2]. PCR bias is very hard to predict; in some cases it is directly related to the number of CpG dinucleotides in the amplicon, but not always. In addition, methylation may be heterogeneous, i.e., only some potential sites are actually methylated. It is difficult to calculate accurate methylation values for fragments derived from heterogeneously methylated sequences. The optimal number of potential methylation sites in amplicons must be determined empirically because it varies significantly among different genomic regions, for reasons that are not well understood. Successful MS-HRM assays have been published with 2 bp amplicons and up to 16 methylation sites. CpG Dinucleotides in PCR Primers When maximum sensitivity of methylation detection is needed, PCR primer sequences can be designed to include CpG dinucleotides. Since unmethylated DNA will contain mismatches to the PCR primers after bisulfite conversion, methylated fragments that match perfectly will be significantly favored in PCR [3]. When the CpG is placed near the 3 end of the PCR primer, specificity for methylated DNA will be even greater. Finally, the PCR bias can be tipped even further in favor of methylated DNA fragments by increasing the annealing temperature in the PCR to discourage amplification of mismatched primers (Figure 2). While this strategy enables detection of very low levels of methylation, the ability to discriminate differences in higher levels of methylation will be compromised. Applied Biosystems Methyl Primer Express Software provides options to specify the number of CpG dinucleotides to be included in the PCR primers as well as their positions. PCR Primers Designed for This Study We designed PCR primer pairs with CpG dinucleotides for sensitive detection of methylation in the % to 2% range, and without CpG dinucleotides for more uniform detection of widely ranging methylation status from % to %. Primer T m values were 58 62 C, and 9 8 7 6 5 2 78.5 79. % % % 79.5 8. 8.5 81. 81.5 82. 82.5 83. 83.5 84. 84.5 79. 79.5 the range of amplicon sizes was 2 bp and included 3 22 potential methylation sites. Step 3: MS-HRM Optimization The goal of optimization is to identify the best PCR primer set and PCR cycling conditions for the differentially methylated region of interest. It is good practice to evaluate PCR reactions by real-time PCR, MS-HRM, and electrophoresis on high-percentage agarose gels. In real-time PCR, C t values should be in the range of 8, and fluorescence should increase exponentially through the exponential phase of PCR. MS-HRM melt profiles from % and % methylated genomic DNA standards should exhibit significant differences. Finally, run the products on an agarose gel to verify that a single product of the expected size is amplified, indicating specificity for the target of interest. Note that in some cases, adjusting annealing (or annealing/extension) temperatures in the PCR can maximize sensitivity for methylated DNA. This is illustrated in Figure 2, which shows amplification of a 1 bp fragment of the Ras protein-specific guanine nucleotide releasing factor 1 (RASGRF1) promoter. To maximize assay sensitivity for methylation, a PCR primer pair containing 3 CpG dinucleotides was chosen. The amplicon in this case contains 9 CpG dinucleotides. Raising the annealing temperature from 6 C to 64 C maximized assay sensitivity for methylation levels in the % range. 8. 8.5 81. 81.5 82. 82.5 83. 83.5 84. 84.5 85. Figure 2. Raising the Annealing Temperature Can Greatly Increase the Sensitivity of the Assay When PCR Primers Contain CpG Dinucleotides. % methylated and % methylated DNA of equal concentration were mixed to mimic DNA samples with 1% and % methylation levels. Triplicate samples of each DNA were subjected to HRM analysis using MeltDoctor HRM reagents on the Applied Biosystems 75 Fast Real-Time PCR System. The PCR primers contain 3 CpG dinucleotides, and they amplify a 1 bp fragment of the RASGRF1 promoter containing 9 CpG dinucleotides. The annealing temperature of the PCR was increased to maximize sensitivity of the assay for methylation levels between % and %. 9 8 7 6 5 2 % 1% % % 9 8 7 6 5 2 79. 79.5 % 1% % % 8. 8.5 81. 81.5 82. 82.5 83. 83.5 84. 84.5 85.

Step 4: MS-HRM Standard Curve and Data Analysis MS-HRM analysis is based on the comparison of melt profiles of experimental samples to profiles from DNA with known methylation levels. Universally (or %) methylated DNA is commercially available. For a source of unmethylated DNA, scientists often isolate DNA from blood mononuclear cells. For this study, DNA from human colon adenocarcinoma cell line HT29 was used as a source of unmethylated DNA because the promoters evaluated are known to be % methylated in this cell line. % methylated and % methylated DNA of equal concentration were then mixed in different ratios to mimic DNA samples with defined levels of DNA methylation. Methylation in the MT1A Promoter To evaluate methylation in the metallothionein 1A (MT1A) promoter, a PCR primer pair without CpG dinucleotides that amplifies a 163 bp fragment containing 13 CpG dinucleotides was chosen. MS-HRM standard melt profiles were generated and used to estimate the level of methylation in 4 human tumor cell lines (Figures 3, 4). Figure 3 illustrates that different levels of methylation resulted in clearly distinguishable melting curves. The data in Figure 4 indicate that differences in MT1A promoter methylation can be clearly identified in the 4 cell lines evaluated. Reactions used Applied Biosystems MeltDoctor HRM Master Mix, and were amplified and subjected to HRM using the Applied Biosystems 75 Fast Real-Time PCR System. Analysis was performed with High-Resolution Melt Software v2.. RASGRF1 Promoter Analysis For methylation analysis of the RASGRF1 promoter, PCR primers were chosen to maximize detection of extremely low levels of DNA methylation; they hybridize to a region containing 3 CpG dinucleotides. The primer sequences are a perfect match for the methylated promoter, and the PCR bias can be verified by comparing the C t values of %, %, and % methylated samples of equal concentrations. We established MS-HRM melt profiles to evaluate methylation levels below 2% by adjusting the annealing temperature of the PCR reaction to 63 C. Note that MS-HRM reactions set up to preferentially amplify 9 8 7 6 5 2 74.5 75. 75.5 76. 76.5 77. 77.5 78. 78.5 79. 79.5 8. 8.5 81. 81.5 82. 82.5 % 75% 5% 25% % % Figure 3. MS-HRM Standard Curves With Uniform Resolution From % to % Methylation. % methylated DNA was mixed in different ratios with DNA from HT29 cells, in which the MT1A promoter is % methylated. The MS-HRM curves (%, 75%, 5%, 25%, %, and % methylation) were generated with a 163 bp PCR fragment containing 13 CpG dinucleotides. 9 8 7 6 5 2 74. 74.5 75. 75.5 76. 76.5 77. 77.5 78. 78.5 79. 79.5 8. 8.5 81. 81.5 82. 82.5 % NCI-H358 NCI-H69 LNCaP NCI-H526 % Figure 4. MS-HRM Analysis of Cell Line DNA. The methylation level of the MT1A promoter in the cell lines NCI-H358, NCI-H69, LNCaP, and NCI-H526 was analyzed by MS-HRM analysis. % and % methylated DNA are shown as well. The methylation level of the MT1A promoter can be estimated by comparing the melting curves of the cell lines with the standard curves. As in Figure 3, MS-HRM curves were generated using a CpG-free PCR primer pair amplifying a 163 bp fragment of the MT1A promoter that contains 13 CpG dinucleotides. MeltDoctor HRM Reagents Applied Biosystems MeltDoctor HRM reagents were developed for high-resolution melt analysis. They employ MeltDoctor HRM dye, a stabilized form of the SYTO -9 dye a next-generation dsdna-binding dye developed by Molecular Probes that is designed to deliver sharp, clean melt profiles. Simplest to use is the MeltDoctor HRM Master Mix; it requires only the addition of template DNA and a PCR primer pair before starting the PCR. When more flexibility in reactions is needed, the MeltDoctor HRM Reagent Kit provides enzyme, fluorescent dye, and dntp mix separately. Both reagent sets employ hot start enabled DNA polymerase, minimizing nonspecific product formation and enabling reactions to be set up at room temperature.

data for one methylation site in DNA standards representing the indicated methylation levels. 9 8 7 6 5 2 79. 79.5 8. 8.5 81. 81.5 82. 82.5 83. 83.5 84. 84.5 85. 85.5 86. 86.5 87. 87.5 88. 88.5 89. Figure 5. MS-HRM Standard Curves With High Resolution Between and 2%. % methylated DNA was mixed in different ratios with DNA from HT29 cells, in which the RASGRF1 promoter is % methylated. The standard curves for methylation were generated with a 1 bp PCR fragment containing 9 CpG dinucleotides. % % 5% 2% 1%.5%.1%.% A Complete Solution Cytosine methylation of genomic DNA is known to have a significant impact in development and disease. There is also increasing interest in identification of DNA methylation based biomarkers. MS-HRM is a simple and cost-effective method to analyze differentially methylated regions such as CGIs in gene promoters. The reaction products can then be sequenced to validate results and identify exact patterns of methylation. Applied Biosystems offers a complete solution for MS-HRM analysis. The methylseqr Bisulfite Conversion Kit enables the user to obtain pure, high-quality bisulfite-converted genomic DNA. Methyl Primer Express 1. Software is available at no charge on our website; it assists in the design of PCR primers targeting bisulfite-converted genomic DNA. The MeltDoctor HRM suite of reagents provides controls and PCR mixes designed to deliver sharp, clean melt profiles. Figure 6. Sequence Data From HRM Products. Detection of the methylation status for one CpG dinucleotide by sequencing DNA samples with known methylation status. methylated sequence require more input DNA PCR products from the MS-HRM analysis to ensure that the unmethylated amplicons were diluted 1: and sequenced directly can be amplified with a C t value <. Figure 5 using the BigDye Terminator v1.1 Cycle shows the MS-HRM standard curves for the Sequencing Kit and Fast cycle sequencing on RASGRF1 promoter with a PCR annealing the Veriti 96-Well Fast Thermal Cycler. temperature of 63 C. Because the DNA concentration in reaction products from HRM analysis is typically Step 5: Sequencing the HRM Product fairly high due to the relatively small amplicon The final step in methylation analysis is size, dilution is necessary prior to DNA to sequence the amplified PCR products sequencing. Dilution ratios >1:2 reduce the to confirm overall methylation levels and concentrations of leftover PCR primers and pinpoint the positions of the methylated C dntps to levels that do not interfere with DNA residues. First, melt profiles for a region of the sequencing reactions. death-associated protein kinase 1 (DAPK1_1) promoter were generated by mixing % and Sequencing reactions were cleaned up using % methylated DNA standards (Figure 6). As the BigDye XTerminator Purification Kit and in previous experiments, DNA from the human run on the Applied Biosystems 31 Genetic colon adenocarcinoma cell line HT29 was used Analyzer using the 36 cm capillary array and as a source of unmethylated DNA. POP-6 polymer. Figure 6 depicts sequencing The StepOne TM, StepOnePlus TM, 75 Fast, 79HT Fast, and ViiA 7 Real-Time PCR Systems enable HRM analysis as well as precise PCR cycling conditions that are crucial for the performance and specificity of PCR with converted genomic DNA as a template. The High Resolution Melting software makes it easy to interpret and present MS-HRM data in an intuitive way. HRM is a nondestructive process; thus, HRM reaction products can be sequenced directly typically, no additional amplification or purification steps are needed prior to sequencing. To further accelerate your time to results, the Applied Biosystems fast resequencing system enables single-day DNA sequencing results.

Real-Time PCR Systems for HRM ViiA 7, 79HT Fast, 75 Fast, StepOnePlus, and StepOne Real-Time PCR Systems are ideal for HRM analysis applications. These instruments: Enable real-time PCR and high-resolution sample melt on a single instrument Perform an optimized, short HRM melt window to decrease time-to-results ViiA 7 Real-Time PCR System Save time by not having to import your data into a standalone HRM software package Select the number of data points collected per degree of melt increment for ultimate flexibility Manually set the number of variants to optimize your results 79HT Fast Real-Time PCR System Hands-free 96- and 384-well robotic plate loading and unloading for true walk-away automation 75 Fast Real-Time PCR System Collect data in a single channel to maximize the data points acquired Variable excitation capacity for optimum excitation of a full range of dyes StepOnePlus and StepOne Real-Time PCR Systems Continuous collection of melt curve data balances speed and resolution, and reduces the amount of time required to obtain high-quality HRM data High Resolution Melt (HRM) Software No temperature-shift correction is needed the result: clear distinction of mutant and wild type samples Autocalling of genotypes and automatic omission of no-template controls for rapid analysis Automatic grouping of unknown variant clusters minimizes subjective analysis Advanced Assay Settings Library for use on routine assays References 1. Dahl C et al. (27) A homogeneous assay for analysis of fmr1 promoter methylation in patients with fragile x syndrome. Clin Chem 53:79 793. 2. Warnecke PM et al. (1997) Detection and measurement of PCR bias in quantitative methylation analysis of bisulphite treated DNA. Nucleic Acids Res 25:4422 4426. 3. Wojdacz TK, Dobrovic A (27) Methylation-sensitive high resolution melting (MS-MS-HRM): a new approach for sensitive and high-throughput assessment of methylation. Nucleic Acids Res 35(6):e41. Scientific Contributors: Andreas R. Tobler, Madeline O Donoghue, and Petra Skare, Applied Biosystems

Life Technologies offers a breadth of products DNA RNA protein cell culture instruments For Research Use Only. Not intended for any animal or human therapeutic or diagnostic use. 2 Life Technologies Corporation. All rights reserved. The trademarks mentioned herein are the property of Life Technologies Corporation or their respective owners. CO15573 11 Headquarters 5791 Van Allen Way Carlsbad, CA 928 USA Phone +1 76 63 72 Toll Free in North America 8 955 6288 www.lifetechnologies.com