A Guide to High Resolution Melting (HRM) Analysis
|
|
|
- Eustacia Davidson
- 10 years ago
- Views:
Transcription
1 A Guide to High Resolution Melting (HRM) Analysis Temperature (C) erozygote Hom - wild type Hom - varian
2 A Guide to High Resolution Melting (HRM) Analysis Table of Contents 1. Introduction About HRM Analysis Fundamentals of Fluorescent DNA Melting Analysis HRM Analysis The HRM Analysis Workflow HRM Assay and Reagent Optimization DNA Quality Amplicon Length Primer Selection Dye Selection HRM PCR Reagents Instruments and Software Troubleshooting Your HRM Experiment Summary Applications Appendix 2 6. References 2 Sidebars Informational Amplicon Length and SNP Detection...1 Human Single Nucleotide Polymorphism (SNP) Occurrence and T m...11 SYBR Green Dye Use in HRM Analysis...13 Definition Autocalling, Variant Calls...8 Tip HRM Analysis of Challenging DNA Samples...9 High-Quality DNA Key to Successful HRM Analysis...9 DNA Quality Considerations for Successful HRM Analysis...9 Primer Design for Successful HRM Analysis...12 Ideal Amplification Properties for Successful HRM Analysis...14 Optimizing PCR Reagents for Successful HRM Analysis...15 Other Suggestions for Successful HRM Analysis...15 Other Resources General HRM...3 Other Troubleshooting Resources...18 Product Primer Design Software...12 Shopping List for HRM Analysis Suggested Reagents...15 Real-Time PCR Systems for HRM Analysis
3 1. Introduction 1. Introduction High resolution melting (HRM) analysis is a new, post-pcr analysis method used for identifying genetic variation in nucleic acid sequences. Simple and fast, this method is based on PCR melting (dissociation) curve techniques and is enabled by the recent availability of improved double-stranded DNA (dsdna) binding dyes along with next-generation real-time PCR instrumentation and analysis software. HRM analysis can discriminate DNA sequences based on their composition, length, GC content, or strand complementarity [1]. HRM analysis differs from standard melt curve analysis in three ways: 1. Chemistry HRM analysis uses brighter dyes at higher concentrations 2. Instruments HRM analysis requires instruments that collect fluorescence data at finer temperature resolution 3. Software HRM analysis requires more sophisticated software which uses new fluorescent scaling algorithms and plots HRM analysis starts with PCR amplification of the region of interest in the presence of a dsdna-binding dye. This binding dye has high fluorescence when bound to dsdna and low fluorescence in the unbound state. Amplification is followed by a high resolution melting step using instrumentation capable of capturing a large number of fluorescent data points per change in temperature, with high precision. When the dsdna dissociates (or melts) into single strands, the dye is released, causing a change in fluorescence. The result is a melt curve profile characteristic of the amplicon. HRM analysis requires no manual post-pcr processing, is performed in a closed-tube system, and has a low reaction cost relative to other methods used to study genetic variation. Other Resources General HRM Applied Biosystems HRM Analysis Site /hrm Applied Biosystems High Resolution Melting Software Getting Started Guide (PN ; view at provides detailed, step-by-step procedures for HRM calibration and analysis using Applied Biosystems instruments and HRM software Applied Biosystems High Resolution Melting Software Help (PN ; view at describes HRM analysis software and procedures for use Oligo Calculators to quickly calculate T m, %GC, molecular weight, and other characteristics of oligonucleotides Applied Biosystems oligonucleotide calculator /support/techtools/tm_calculator.cfm OligoCalc PCR design software Primer Express software, included with Applied Biosytems instruments /primerexpress Methyl Primer Express software /methylprimerexpress Primer3 Primer3Plus Gene Quantification Information HRM is a relatively new method, and this guide provides a resource for scientists learning and perfecting the technique. Along with an introduction to HRM analysis, information is provided on reaction optimization and technical problem solving. 3
4 1. Introduction 1.1 About HRM Analysis In HRM analysis, the region of interest is amplified by PCR in the presence of a fluorescent dsdna-binding dye. Following PCR, the product is gradually melted, and the emitted fluorescence is measured on a specialized instrument to generate a characteristic curve. The resulting melt profile reflects the mix of amplicons present. Aspects such as GC content, length, sequence, and heterozygosity will add to the melt curve characteristics for each amplicon. The resulting profiles can provide valuable information for mutation screening, genotyping, methylation, and other investigative applications. HRM analysis uses two profile observations: 1. Melt curves that are similar in shape but that are distinguishable from each other by differences in melting temperature (T m) of the amplicon. Typically, such profiles are generated by homozygous variant samples that are being compared to a wild type sample. In such situations, the T m difference between samples is due to sequence variation from the wild type. 2. Melt curves displaying a curve shape distinct from homozygote melt curves. These profiles are usually due to the presence of base-pairing mismatches (heteroduplexes) present in the PCR product mix. Figure 1 provides an example of HRM analysis data to illustrate the different types of resulting profiles. Aligned Fluorescence (%) hom G hom A het Figure 1. High Resolution Melt Curve With a Single Point Mutation. This is an aligned melt curve. The plot demonstrates the sharp decrease in fluorescence when the double-stranded DNA melts into its single-stranded form. Red = homozygous with guanine, Green = homozygous with adenine, Blue = heterozygous. 4
5 1. Introduction 1.2 Fundamentals of Fluorescent DNA Melting Analysis Standard DNA melt curve analysis is a post-pcr analysis method based on a biophysical measurement of the amplified DNA. Historically, it has been used for various applications, most commonly to detect primerdimers or other nonspecific by-products of PCR. A melt curve is generated by slowly denaturing (melting) the DNA sample through a range of temperatures in the presence of a dsdna-binding dye. During melting, only dye bound to dsdna fluoresces, and that fluorescence is continuously detected by an optical system. Fluorescence is high when the dye is in its bound state, but when in solution, the dye changes conformation and fluorescence decreases 1,-fold. The extent of melting is measured by the change in fluorescence of the DNA sample. At low temperatures, the DNA will be double-stranded and the dye will strongly fluoresce. As the temperature increases, fluorescence will decrease 1,-fold as the dye is released when the two strands denature. This decrease in fluorescence starts slowly, but when the double-stranded DNA melts into its single-stranded, fully denaturated form, a sharp decrease in fluorescence is detected (Figure 2A). The rate of fluorescence decrease is generally greatest near the melting temperature (T m) of the PCR product. The T m is defined as the point in the melt curve where 5% of the DNA is double-stranded and 5% is single-stranded (melted). It equals the temperature at which the aligned fluorescence is 5% and is a function of PCR product characteristics, including GC content (T m is higher in GC-rich PCR products), length, and sequence content. Melt curve raw data are generally plotted as fluorescence vs. temperature. In general, melt curve analysis software defines the T m of a PCR product as the inflection point of the melt curve. To visualize the T m more clearly, the negative first derivatives are often plotted, making the T ms of the products appear as peaks, as seen in Figure 2B. Nonspecific products may also appear in the derivative curve. These peaks are typically of lower intensity and represent products that are shorter in length, thus appearing at a lower temperature than the primary product. Because primer-dimers and other nonspecific PCR products can be seen in this data view, it can be a useful measure of PCR product purity. 2,. 4,. 4,. 35,. 15,. 3,. Normalized Reporter (Rn) 25,. 2,. 15,. 1,. Derivative Reporter (-Rn) 1,. 5,. 5, Tm Tm Panel A. Standard Melt Curve. Panel B. Derivative Melt Curve. Figure 2. Real-Time PCR Data Showing a DNA Melt Profile. (A) A standard melt curve plot, showing the high initial fluorescence when all products are double-stranded and the maximum amount of dye is bound. As the temperature increases, the PCR products denature, dye is released, and the fluorescent signal drops. The vertical line is the point where 5% of the PCR products in the sample are denatured. (B) A derivative melt curve plot, which shows the inflection point on the slope as a more easily visualized melt peak. 5
6 1. Introduction 1.3 HRM Analysis In HRM analysis, the same fundamental principles of DNA melt curve analysis are applied along with further refinements. Complex alignment algorithms and new plot views are introduced so that small differences in melt curve data can be seen. Figure 3 illustrates the typical process of data alignment using the Applied Biosystems HRM Software v2.. Pre- and post-melt regions are defined by pairs of vertical bars placed before and after the active melt region. The area of data between the pair of bars to the left of the active melt region is used by the software to designate 1% fluorescence where every amplicon is double-stranded. This level is shown at the far left of the aligned melt curve in Figure 3. The change in fluorescence for each sample, seen to the right of the 1% fluorescence point, is scored as the true fluorescence change and is used to plot the aligned melt curve (Figure 3). The post-melt region is delineated by the pair of parallel lines to the right of the active melt region, and is used by the software to determine the % fluorescence point where every amplicon is single-stranded. The aligned plot provides a scaled view of the data, enabling easy discrimination of sequence variants that display true differences in their melt curve behavior. This is in contrast to the raw data, which are affected by the variable intensity of fluorescence between each sample. Often, differences between melt curves are small. Small differences are best visualized using a difference plot (Figure 4). In this plot, sample curves are subtracted from a single reference (typically a wild type control), run in the same experiment. Fluorescence (RFU) 5,5, 5,, 4,5, 4,, 3,5, 3,, 2,5, 2,, 1,5, 1,, 5, Pre-melt region Active melt region Post-melt region Temperature ( o C) Figure 3. Raw Data Melt Curve. Data collected during a high resolution melt curve experiment exhibit a range of initial fluorescence readings, making it difficult to discriminate differences in the change of fluorescence for individual samples. The active melt region is designated by pre- and post-melt regions (double bars) that are used to align the data, producing a clearer view of the melt curve results. (Curve colors represent different samples.) hom wt het Difference Figure 4. HRM Analysis Data Difference Plot. Sample curves are subtracted from a reference curve (usually a wild type control). This view accentuates differences between similar melt curves. Green = wild type, Red = homozygous, Blue = heterozygous. 6
7 1. Introduction 1.4 The HRM Analysis Workflow The actual HRM analysis workflow is simple (Figure 5); most of the work lies in the optimization of the PCR primers, reagents, and reaction conditions (Step 2). Step 1. Instrument Calibration (for Applied Biosystems 75 Fast or 79HT Fast Real-Time PCR Systems). The instrument used for the PCR amplification and HRM analysis should be calibrated once every six months. This step includes running a background, custom dye, and HRM calibration plate. For more information on the calibration procedure, refer to Applied Biosystems High Resolution Melting Software Getting Started Guide (PN ; view or order from ). Step 2. PCR Design and Optimization. This step requires the most attention. It includes careful design of primer sets, and the selection and testing of PCR reagents, HRM dyes, and reaction controls (see page 8, PCR Assay Development & Optimization, for more information). Step 3. PCR. Use of a real-time PCR system for amplification is recommended, particularly when optimizing or troubleshooting an assay, as PCR amplification can be monitored in real time, providing information on amplicon quality. The data can also be checked for melt analysis suitability and saved in the appropriate file format (see page 8, PCR Assay Development & Optimization, for more information). When a real-time PCR system is used, Steps 3, 4, and 5 may be completed on the same instrument. Alternatively, PCR may be performed on a standard PCR thermal cycler followed by transfer to a real-time PCR system for HRM. Step 4. Sample Melt. On a real-time PCR system, samples are melted and the data collected. When a standard thermal cycler is used for the PCR, the samples must be transferred to a real-time PCR instrument designed to collect HRM melt curve data. Step 5. Data Analysis. The PCR data file is imported into the HRM analysis software and the data are analyzed. 1 gtgaggctcc gcccctccct ttgcaggacg tcacggagga 51 gctgccgccg ccgccgcgca gcccacatc aacgcaccg 11 caaaaaagtc accgccgcta gggtcgccgt tgcatcggtg 151 cacagactcg cgctatgggc agaaggagtc ctcggatcag 21 gattcacatc atcggcaaca gcagcgtggg caagacgtcc 251 ctatcgcaac gacaagagga tcaagctgca attacgtcca 31 gatctgggac ctatcgcaac tcaagctgca gatctgggac 351 ccggaccacc accaccgcat actaccgggg cgctatgggc 41 caccaacgag gaatccttca atgcagtgca ggactggtcc 451 atcccacaat ccccacctcc tcctaatacc aaacaactot Aligned Fluorescence (%) G A G/A Step 1: Instrument Calibration* Step 2: PCR Design & Optimization Step 3: PCR Step 4: Sample Melt Step 5: Data Analysis Calibrate your instrument of choice for both background and your HRM dye *Only required once every six months Design your PCR primers, and optimize PCR reaction Perform PCR using optimized conditions and reagents; Steps 3, 4, and 5 can be combined when using a real-time PCR system Melt samples in real time Analyze melt data and output profiles 79HT Fast Real- Time PCR System 75 Fast Real-Time PCR System MeltDoctor HRM Calibration Plate Primer Express Software v3. MeltDoctor HRM Master Mix MeltDoctor HRM Reagent Kit MeltDoctor HRM Positive Control Kit HRM Software v2. Figure 5. The HRM Analysis Workflow. 7
8 2. HRM Assay and Reagent Optimization 2. HRM Assay and Reagent Optimization For successful analysis, care should be taken in assay development to ensure that the experiment is optimized for HRM. Small differences in melt curves can arise from sources other than sequence, such as genomic DNA (gdna) quality, carryover of extraction impurities, amplicon length, primer design, dye selection, and PCR reagent choice. The following sections address these factors. Definition Autocalling An automated grouping of sequences deemed by the analysis software to have similar HRM curve shapes and Tm. Variant Calls Groups of sequences determined by the software analysis parameters to have similar mismatches, insertions, or deletions distinct from any user-defined controls. These groups are designated variant 1, variant 2, etc. 2.1 DNA Quality One of the biggest factors associated with DNA quality that can impact HRM results is salt carryover, as it will subtly change the thermodynamics of the DNA melting transition. If not controlled for, salt carryover and other experimental artifacts can complicate the interpretation of DNA melt curves, leading to lower reproducibility and higher error rates in HRM variant calls. Some commercial DNA isolation kits use high salt (1 M) for nucleic acid elution from columns or filters. These samples will need to be precipitated and resuspended in a low-salt buffer such as TE (1 mm Tris, 1 mm EDTA) prior to PCR. ph extremes resulting from NaOH usage in isolation procedures can also carry over and impact HRM analysis. Precipitation and resuspension in TE can remedy this. Dilution of the sample in both situations can also help. Panel 6A shows the difference plot obtained from amplification of poorquality DNA samples. The extraction method used for these samples resulted in carryover of PCR contaminants and salts, which had dramatic effects on the melt curves. The multiple peaks and large spread of the amplicon populations create a complex pattern that is difficult to interpret. Panel 6B shows a difference plot of the same DNA samples from 6A, having undergone dilution prior to PCR amplification. The decreased salt and other contaminants in the PCRs resulted in melt profiles that were smoother, more tightly grouped, and easier to separate into clear clusters Difference variant 1 variant 2 variant 3 variant 4 Difference Panel 6A. Difference Plot of Salt-Contaminated DNA Samples variant 1 variant 2 variant 3 variant 4 variant 5 Figure 6. Difference Plots of Contaminated DNA Samples. DNA sample variants were isolated using a commercial isolation kit employing a highsalt wash, resulting in salt-contaminated DNA. Samples were split, and half were diluted 1:1 in water. Difference plots of HRM analysis of the (A) undiluted and (B) diluted samples are shown, illustrating how dilution of a contaminated sample can often increase data quality Panel 6B. Difference Plot of Diluted, Salt-Contaminated DNA Samples. 8
9 2. HRM Assay and Reagent Optimization Low-quality DNA may produce nonspecific PCR products, ultimately resulting in incorrect scoring of results in HRM analyses, or failed reactions. Samples that amplify late or fail to reach a high signal plateau in the PCR phase can result in inconclusive or low-resolution HRM data [2]. For the best results, all DNA samples in an analysis run should be prepared using the same method. DNA input amount into the PCR should also be similar. Furthermore, HRM analysis should be performed immediately following PCR whenever possible. If immediate analysis is not possible, the PCR products can be stored at 2 C for subsequent remelting, reamplification, or sequencing. Tip: HRM Analysis of Challenging DNA Samples More challenging DNA samples can be used successfully in HRM analysis when combined with robust reagents and instrumentation. For example, genomic DNA isolated from formalin-fixed, paraffin-embedded (FFPE) tumors has been used successfully to identify SNP variants (see page 2, Identifying Variants by High Resolution Melting (HRM) in Difficult Samples; also DNA Genotyping from Human FFPE Samples Reliable and Reproducible; publication 137AP4-1, available at ). Tip: High-Quality DNA Key to Successful HRM Analysis In a recent study, scientists amplified 7 DNA samples of varying quality in an attempt to determine the effect on HRM analysis. The DNA samples were amplified using a multiplexed control gene primer set designed to produce products of 1, 2, 3, 4, and 6 bp with equal intensity. Loss of the higher molecular weight products indicated that the DNA sample was of poor quality. HRM data were correlated with the DNA quality and amplification plot data; poor DNA quality was shown to have a negative impact on the quality of the HRM analysis. Therefore, care should be taken to prepare full-length DNA when at all possible. It is also recommended that the amount of DNA template used in PCR be consistent between samples, since large differences in starting template can impact the resulting Tm. (National Genetics Reference Laboratory (Wessex) Technology Assessment Tip: DNA Quality Considerations for Successful HRM Analysis Use the same method to prepare DNA from all samples in an experiment Use the same reagents during DNA isolation, including the sample buffer salt concentration, for all samples and controls in the experiment Watch for contamination carryover from the DNA purification procedure Use similar DNA input amounts for all samples 9
10 2. HRM Assay and Reagent Optimization 2.2 Amplicon Length Amplicon lengths of 1 3 bp are generally recommended for HRM analysis of different sequence variants, including single nucleotide polymorphisms (SNPs), inversions, insertions, and deletions. While large sequence variations between amplicons can be detected for amplicons longer than 3 bp, more subtle variations such as A/T class 4 SNPs typically require smaller amplicons for detection. SNP Genotyping When designing primers for HRM SNP genotyping analysis, the amplicon length should be short to avoid the detection of SNP variants outside of the region of interest. However, smaller amplicons may produce lower fluorescence signals, presumably due to less dye incorporation in the shorter sequence. In order to ensure adequate dye fluorescence signals, the amplicon length should be approximately 8 1 bp, including primers (target sequence length of 3 bp in addition to two 25 bp primer sequences). Informational: Amplicon Length and SNP Detection Data show how amplicon lengths ranging from 12 to 313 bp can impact HRM analysis for SNP detection (a single point mutation of A/G). Applied Biosystems HRM Software v2. can correctly identify the two homozygous and the heterozygous mutants at all the amplicon lengths tested; however, there are distinct differences in the resolutions of the mutants. The clearest discrimination of the mutants is seen when the shortest amplicon (12 bp) is used and the Tm difference between the two homozygotes is near.5 o C. The distinction between the two homozygous populations begins to diminish when the amplicon is 22 bp and continues to diminish as amplicon size increases. As amplicon size increases, it is possible that additional mutation sites will be detected, which will result in a more complex melting pattern where it becomes more difficult to distinguish between the different sequence variants (not shown). Aligned Fluorescence (%) hom het wt Panel A. 12 bp Amplicon Aligned Fluorescence (%) hom het wt Panel B. 22 bp Amplicon Aligned Fluorescence (%) hom het wt Panel C. 233 bp Amplicon Aligned Fluorescence (%) hom het wt Panel D. 313 bp Amplicon Figure 7. Effect of Increasing Amplicon Size on HRM Analysis. 1
11 2. HRM Assay and Reagent Optimization Mutation Scanning When using HRM analysis to scan for unknown mutations, the entire gene length needs to be scanned, and the amplicon length used can be long, typically 3 bp. The genomic region of interest should be divided into amplicons with lengths <25 bp, which will produce 3 bp amplicon sequences when 25-mer forward and reverse primers are used. Target sequences should overlap by at least 25 bp to ensure complete coverage of the region of interest (Figure 8). Informational: Human Single Nucleotide Polymorphism (SNP) Occurrence and T m Table 1 lists the SNPs found in the human genome, their classification, expected Tm difference between the two homozygous populations of each sequence variant, and their occurrence. Class 1 and 2 SNPs are easier to detect by HRM analysis and occur at a higher percentage in the human genome compared with the more difficult-to-distinguish Class 3 and 4 SNPs. SNP Class Base Change Typical Tm Curve Shift Occurrence in the Human Genome 1 C/T & G/A Large (>.5 C, avg. 1. C) 2 C/A & G/T Large (>.5 C, avg. 1. C) 3 C/G Small (.2.5 C) 4 A/T Very small (<.2 C) 64% 2% 9% 7% Table 1. Human Single Nucleotide Polymorphism (SNP) Occurrence and Tm. 1,5 bp region of interest Chromosome Figure 8. HRM amplicons, approximately 3 bp in length, should be designed to overlap by at least 25 bp to ensure complete coverage of the region of interest. 11
12 2. HRM Assay and Reagent Optimization 2.3 Primer Selection Because the dyes used in HRM analysis bind generically to any doublestranded DNA products, PCR primers need to be designed for robust performance and must be specific to the region of interest. A common check of specificity is a BLAST search. The Basic Local Alignment Search Tool (BLAST) on the NCBI site ( quickly checks your primers for regions of similarity to other known sequences. It is good practice to design three sets of primers. Having multiple primer sets to choose from helps to ensure you will have at least one highly robust pair. Each primer pair should be tested for specificity to the target of interest and produce a minimum of primer-dimers and nonspecific products. PCR followed by melt curve analysis should be performed to look for nonspecific products and primer-dimers. In addition to the standard analysis, melt profiles should also be viewed in low resolution to see these other products. HRM software may not be able to detect all nonspecific reaction products if their melt profiles are similar. As a consequence, it is best practice to initially assess PCR products from each primer pair by agarose gel electrophoresis. Once the best primer set is chosen, other reaction factors can be further optimized. It is advisable to perform HRM analysis on a real-time PCR instrument for the built-in PCR quality check the instrument can provide (see page 16, section 2.6, Instruments & Software, for additional information). If the proper pilot studies have been done for the chosen primer set, the real-time reactions will provide information about DNA template quantity and quality. The length of the resulting DNA amplicon may also impact the sensitivity and specificity of subsequent HRM analysis. One study found that mutations were more difficult to detect in amplicons longer than 4 bp [2]. Melt profiles generated by shorter amplicons tend to be less complex than those generated by longer amplicons; as a result, shorter amplicons are easier to analyze. The relative change in fluorescence intensity of smaller amplicons is greater than for longer amplicons; however, care should be taken to not make the amplicons too short, as the overall fluorescence will be reduced when there is less double-stranded product to which the dye can bind. For more information, see Amplicon Length in section 2.2, on page 1. Tip: Primer Design for Successful HRM Analysis Use amplicons with a target length of <3 bp to ensure sensitive detection of sequence variants Check primer sequences for known variations, annotations, and species specificity Order three primer sets to empirically determine the most robust pair Primer T m should be between 58 C and 6 C HPLC purification of primers may help troublesome reactions A variety of software tools are available to help design HRM primers, including Primer Express 3. Software, Primer3, and Primer3Plus Product: Primer Design Software Primer Express 3. Software Applied Biosystems Primer Express 3. Software is a primer and probe design tool made specifically for use with Applied Biosystems Real- Time PCR Systems. Primer Express allows you to independently design oligonucleotides for PCR applications. The software is simple to use. First, a file of the DNA sequence of interest is imported into the program. Use the default settings for TaqMan design and select find primers/probes now. All acceptable primer and probe sets for your sequence of interest are returned. The software format results in a text document that can be copied into an for easy primer ordering. Because HRM analysis does not use TaqMan probes, that information is simply discarded. To design primers for HRM analysis of genotypes with known mutations, use the TaqMan MGB Allelic Discrimination Design Document in Primer Express 3. and input the SNP information as if designing a TaqMan SNP Genotyping Assay. Figure 9 shows a sample melt profile of a Class 1 SNP (dbsnp rs18128) for the N-acetyltransferase 2 gene. The primer set was designed using the default settings in Primer Express 3. and analyzed in the HRM Software v2.. Aligned Fluorescence (%) G A G/A Figure 9. Melt Profile of Class 1 SNP. Primers were designed using Primer Express 3. Software. Methyl Primer Express Software v1. Primer Design for MS-HRM Analysis HRM analysis can also be used to detect methylation differences between genes; this is known as methylation-specific high resolution melting (MS-HRM) analysis (see page 17, Chapter 3, Methylation-Sensitive High- Resolution Melting Analysis on 75 Fast Real-Time PCR System). It is known that PCR primers are biased toward nonmethylated fragments; as a result, nonmethylated fragments amplify more efficiently than the methylated fragments, affecting assay sensitivity, particularly at the lower limits of detection. To accurately detect methylation in the % to 2% range, include CpG dinucleotides in the PCR primer sequences. CpG sequences bias the amplification towards the methylated fragments of DNA, but can negatively affect the sensitivity of detection. Using Methyl Primer Express Software v1., primers can be designed with a specified number of CpG dinucleotides for optimized reactions. This free software is available for download at /methylprimerexpress. 12
13 2. HRM Assay and Reagent Optimization 2.4 Dye Selection HRM analysis uses double-stranded DNA (dsdna)-binding dyes that, at relatively high concentrations, do not inhibit PCR [3]. The amount of fluorescent dye bound to double-stranded DNA can vary with amplicon length, composition, and PCR conditions. Too much dye can stabilize the double-stranded form, artificially shifting the T m or inhibiting PCR; too little dye can result in low signal and inaccurate results. Ideally, the optimal dye concentration should be determined by empirical testing with a titration experiment. Dye concentrations slightly higher and lower than the recommended starting concentration should be tested to determine the concentrations that gives maximum fluorescence without inhibiting the PCR. Informational: SYBR Green Dye Use in HRM Analysis Standard PCR-based melting (dissociation) curve analysis was introduced about a decade ago and originally used SYBR Green I dye as the dsdnabinding dye [1]. Until recently, SYBR Green I dye has been discouraged for HRM analysis because it has been shown to inhibit PCR at high concentrations [4] and has been hypothesized to redistribute from melted regions back into the dsdna amplicon [2,5]. These results may have been due to the decreased sensitivity of the early instrumentation used in these studies. Today, there is evidence that SYBR Green I is suitable for use in HRM analysis for some applications, although it may be more difficult to optimize those reactions, and its success in HRM analysis may be instrument dependent [6]. These dyes are photosensitive and should be protected from light when not in use. Some dyes are not stable in their diluted form, so fresh dilutions must be prepared for each experiment. The manufacturer s instructions should be closely followed for storage and dilution. The dyes used for HRM analysis are double-stranded DNA-binding dyes that are brighter than those previously used, and do not inhibit PCR at high dye concentration. Dyes commonly used for HRM analysis include: SYTO 9 Green Fluorescent Nucleic Acid Stain (included in MeltDoctor HRM Reagents) EvaGreen Dye SYBR GreenER Dye SYBR Green I Dye (see sidebar, SYBR Green Dye Use in HRM Analysis, for restrictions) Several different HRM dyes should be tested to determine which functions best in your experimental system. One factor affecting dye functionality is the instrument itself, since different instruments use different excitation sources and detection methods. Reagent choice along with characteristics of the amplicon may also influence the effectiveness of the dye. Whichever dye is chosen, the reaction should be optimized for that specific dye, as each dye interacts uniquely with all other reaction components, impacting the ultimate sensitivity of the analysis. 2.5 HRM PCR Reagents Reagents for HRM analysis and reaction conditions should be optimized to result in robust and specific PCR. Primer-dimers and other nonspecific products can significantly decrease performance of the HRM analysis, so in addition to optimizing reactions, one must ensure that variation is not introduced by improper assay design and optimization decisions. Use PCR reagents that have been validated or optimized for HRM analysis, when available. Hot-start enzymes, such as that included in the AmpliTaq Gold 36 Master Mix, are also recommended, as they increase primer specificity. Table 2 shows a basic PCR setup for HRM analysis. Starting with these recommendations, the reaction can be further optimized by testing for optimal primer sets, MgCl 2 concentration, template concentration, and other components. Component Volume (µl/rxn) 2X Master Mix 1 Magnesium Chloride Solution, 25 mm Variable Forward Primer, 5 μm 1.2 Reverse Primer, 5 μm 1.2 SYTO 9 Dye, 5 μm *.6 gdna (5 ng/μl) 5 Deionized Water Variable Total Reaction Mix Volume 2 *Substitute other dye if desired Table 2. Recommended PCR Setup for HRM Analysis Using a Core Kit. 13
14 2. HRM Assay and Reagent Optimization Effects of MgCl 2 Concentration on HRM Analysis The effect of MgCl 2 concentration on HRM analysis for detection of a single G/C point mutation is shown in Figure 1. Quadruplicates of each sequence variant were amplified in the presence of either 1 mm, 2 mm, 3 mm, or 4 mm MgCl 2. One representative of each homozygous variant G for each of the MgCl 2 concentrations was chosen as a control. The reference curve for the difference plot is a G control with 1 mm MgCl 2 (1 mm G). The autocalled group termed variant 1 contains C variants with 1 mm MgCl 2 concentration. The large gap between the two populations is ideal for easy discrimination of the two variant groups. At the 2 mm concentration (2 mm G), all the G and C variants cluster together (dark blue lines). This clustering is also seen at the 4 mm MgCl 2 concentration (4 mm G; red lines). The 3 mm G (3 mm MgCl 2 concentration, G variant; purple and the light blue autocalled variant 2 cluster that represents C variants at 3 mm MgCl 2 ) are distinctly separated into 2 variants, but the separation is much smaller than seen with the 1 mm G samples (dark green). This example clearly shows the effect of MgCl 2 on HRM results and highlights the need for a MgCl 2 titration when optimizing the PCR for HRM analysis. Optimal annealing temperatures and cycle number for your system and reagents should also be determined. An optimized PCR will have a profile like that seen in Figure 11, and will display the properties described in the box, Ideal Amplification Properties for Successful HRM Analysis. Whenever possible, samples with a known variant type should be prepared by the same procedure as unknown samples, and should be included on each PCR plate as a control. Tip: Ideal Amplification Properties for Successful HRM Analysis Exponential phase of amplification is strong and steep C t values of 2 25 Reactions reach plateau Samples amplify similarly Rn 1,, 1,, 1, 1, 1, Cycle Figure 11. Ideal Amplification Properties for Successful HRM Analysis. Difference mm G 2 mm G 3 mm G 4 mm G variant 1 variant Figure 1. MgCl 2 Concentrations Affect HRM Analysis of a Single Point Mutation. Quadruplicates of each sequence variant were amplified in the presence of either 1 mm, 2 mm, 3 mm, or 4 mm MgCl 2, and the results were viewed as a difference plot. 14
15 2. HRM Assay and Reagent Optimization Shopping List for HRM Analysis Suggested Reagents Item Size Part Number Forward and reverse PCR primers (optional: HPLC purified) Appropriate HRM products for your instrument MeltDoctor HRM Master Mix 5 ml 5 x 5 ml 1 x 5 ml 5 ml Custom MeltDoctor HRM Positive Control Kit 1 kit MeltDoctor HRM Reagent Kit 1 kit MeltDoctor HRM Calibration Plate well plate 1 Fast 96-well plate MeltDoctor HRM Calibration Standard 1 tube, 1 ml Appropriate reaction plate for your instrument MicroAmp Optical 384-Well Reaction Plate with Barcode.1 ml, 5 plates ml, 1, plates MicroAmp Optical 96-Well Reaction Plate with Barcode.2 ml, 2 plates MicroAmp Optical Adhesive Film Tip: Optimizing PCR Reagents for Successful HRM Analysis Optimize the primer concentration start at 3 nm Optimize the MgCl 2 concentration start between 1. mm and 3. mm Use an AmpliTaq Gold enzyme optimized for PCR performance, such as AmpliTaq Gold 36 Enzyme Test different primer pairs to determine which one is optimal Include proper controls for PCR and variants Include replicates for significance triplicates are recommended Tip: Other Suggestions for Successful HRM Analysis Use calibrated pipettes to ensure accurate pipetting Set up reactions on ice to minimize sample degradation and nonspecific reactivity Mix reagents well Keep reaction volumes at 2 µl or above, to minimize pipetting and mixing errors Be sure plates are well sealed Centrifuge before placing in the real-time instrument Run samples within 2 hr of preparing Prepare fresh master mix as needed 15
16 2. HRM Assay and Reagent Optimization 2.6 Instruments and Software HRM Analysis Instrumentation HRM analysis requires a PCR thermal cycler and an instrument with optics capable of collecting the numerous fluorescent data points; it is best when one instrument can perform both functions. Dual-capability real-time PCR instruments are found in two designs: Rotary samples spin past an optical detector Block-based instruments samples are read by a scanning head or stationary camera In block-based systems, a Peltier block is used for precision temperature control (see box, Real-Time PCR Systems for HRM Analysis). Using a real-time PCR system for both PCR and sample melt provides several advantages, including: Walk-away automation no need to handle samples after loading Built-in quality check provides information on PCR efficiency as well as detecting PCR failure or late C t ; performing melt analysis on samples from poor PCR amplifications can produce spurious HRM results Alternatively, PCR can be performed on a thermal cycler followed by transfer to a real-time instrument or another device for sample melt and data analysis. HRM Analysis Software Software for HRM analysis needs to be capable of handling the large amounts of data generated during an HRM experiment. Most HRMspecific software uses new algorithms and display plots that help discriminate DNA variants in HRM data. A good HRM software package should: Product: Real-Time PCR Systems for HRM Analysis Applied Biosystems 75 Fast and 79HT Fast Real-Time PCR Systems are ideal for HRM analysis applications. Both instruments: Enable real-time PCR and sample melt on a single instrument Maximize sensitivity to detect true variants and minimize false negative results 75 Fast Real-Time PCR System Use of Expert Mode to collect data in a single channel, maximizing the number of data points acquired during an HRM run Performs an optimized, short HRM melt window to decrease time-to-result Variable excitation capacity for optimum excitation of a full range of dyes 79HT Fast Real-Time PCR Systems Combines 96- and 384-well plate compatibility with fully automated robotic loading. Hands-free plate loading and unloading provides true walk-away automation, allowing you to increase your lab s productivity Interchangeable blocks for flexibility in throughput HRM Analysis Software Avoid the need for temperature shift correction, resulting in easy distinction between homozygous, mutant, and wild type samples Shorten analysis time by autocalling genotypes and automatically omitting the no-template controls Minimize subjective analysis by automatically grouping unknown variant clusters Provide a view of the raw fluorescent melt data Provide a process to align that data View melt curve differences between samples The Aligned Melt Curve is a typical starting view. The pre- and post-melt scaling regions are set within the software by the user or automatically through default software settings and define the data window used for this plot. Placement of the pre- and post-melt regions can affect resulting clusters and classifications of the HRM analysis results. The pre-melt region, in many instances, is the most critical, as correct placement of these bars can maximize differences between the variants, as characterized by their initial melt profile in the first stages of the active melt region. Care must be taken to ensure a region is chosen that is representative of the initial fluorescent levels. Usually this is quite close to the start of the active melt region, without actually encroaching on the melt curve itself. Viewing the melt data in the derivative view (Figure 12) can be useful when selecting the appropriate region for alignment. 16
17 2. HRM Assay and Reagent Optimization Applied Biosystems HRM Software provides a variant or cluster result based on similarities of melt curve placement and shape. Controls can be used for comparison with experimental samples, providing detail on any differences present. When a sample clusters with a control, it is an indication that they are the same sequence. However, because HRM dyes bind nonspecifically, and different sequence variants can, at times, exhibit the same or very similar melt profiles, it is always good practice to confirm your HRM results with a more specific method, such as a TaqMan Real-Time PCR Assay or direct sequencing. Fluorescence (RFU) 1,2 1,1 1, Temperature ( o C) Figure 12. Using the Derivative View to Place Pre- and Post-melt Settings. This view can help ensure that the set preand post-melt regions do not encroach on the active region of the melt data. Colors represent different sample runs. Pre-melt region Active melt region 17
18 3. Troubleshooting Your HRM Experiment 3. Troubleshooting Your HRM Experiment Problems with HRM experiments are usually evidenced by (1) abnormal PCR characteristics such as high C t values or the presence of extra products, or (2) nonstandard melt data such as a wide spread in HRM curves from replicate samples or HRM curves with multiple melt domains. Table 3 identifies the sources of such anomalous data and provides recommendations for resolution. The sidebar, Other Resources Other Troubleshooting Resources, gives additional guidance. Other Resources Other Troubleshooting Resources Real-Time PCR Online Troubleshooting Tool: /troubleshoot HRM Getting Started Guide: documents/generaldocuments/cms_5347.pdf Aberrant PCR Results Abnormal HRM Data Observation Issue Effect on results Try More information C t of majority of samples is >3 C t of some samples >3 Amplification curves less steep and C t values higher than expected Presence of nonspecific products in PCR or larger than expected spread in HRM data Presence of extra melt curves (usually at lower temperature than expected product) Replicate samples show wide spread in HRM curves Complex melt curves with multiple melt domains Multiple melt domains in HRM curve or more than three distinct clusters, often with more than one heterozygous cluster Very messy HRM curves, usually present as diagonal wavy curves below heterozygous clusters Late amplification Some late amplification PCR inhibition Incorrect salt concentration Nonspecific products Replicates are widely spread Multiple melt regions More than three clusters in genotyping experiment Untasked notemplate controls Reaction may not reach plateau and HRM resolution may be affected due to lower overall fluorescence gain Sample outliers with higher C t than rest of group will have a T m shift in HRM curve that may affect cluster calling Reaction may not be reaching plateau, affecting HRM resolution; HRM melt may also be inhibited Salt concentration affects PCR specificity as well as melting properties of amplicons PCR efficiency affected and presence of extra amplicons may impact melting behavior of true targets Wide population spread leads to difficulty in assessing true sequence differences, particularly between two different homozygous populations Presence of more than one mutation site can result in complex melt curves that may be difficult to interpret; long sequences can also contain multiple melt regions in the absence of an SNP due to regional sequence context of amplicon Presence of unknown SNPs in amplicon can create multiple heterozygous and homozygous amplicons; long sequences can also contain multiple melting regions in the absence of a SNP due to regional sequence context of amplicon Neglecting to omit negative controls and unamplified samples from HRM analysis will skew pre- and post-melt settings and interfere with software cluster calls Increase sample input or number of amplification cycles (beware of nonspecific amplification) Check relevant wells for volume discrepancies, look for signs of inhibition in amplification curve, increase sample input Dilute DNA samples 1:1 or 1:1, or re-extract DNA from original sample material Perform MgCl 2 titration to find best salt concentration for each reaction (note DNA eluate salt levels) Ensure primer specificity with BLAST search; run product on gel to ensure single band; perform MgCl 2 titration Ensure appropriate salt concentrations, ensure similar DNA starting concentrations; ensure efficient PCR; consider using multiple controls for HRM analysis to assist in defining population spread Redesign primers; decrease amplicon size; sequence samples to confirm results Sequence product to confirm presence of additional SNP; redesign primers; reduce amplicon size Test negative controls with instrument software and ensure that negative results are omitted from HRM analysis Review Chapter 2 (p. 8), especially 2.1: DNA Quality Review Chapter 2 (p. 8) and see online PCR troubleshooting tool (listed in sidebar) Review Chapter 2 (p. 8) and see online PCR troubleshooting tool (listed in sidebar) Review Chapter 2 (p. 8), especially 2.1: DNA Quality Review Chapter 2 (p. 8) and see online PCR troubleshooting tool (listed in sidebar) Review Chapter 2 (p. 8) Review Chapter 2 (p. 8) Review Chapter 2 (p. 8) See the HRM Getting Started Guide (listed in sidebar) Table 3. Troubleshooting Your HRM Experiment. 18
19 4. Summary 4. Summary This guide has provided a starting point for performing robust HRM experiments. The most important take-home message is the need to optimize the PCR step. Strong PCR will lead to HRM data that are easier to analyze, thus providing clearer results in which you can have more confidence. By optimizing sample quality, adjusting amplicon length for the desired application, confirming the specificity of primers, using the appropriate concentration of the chosen dye, defining the best reagent concentrations, and choosing an effective instrument and data analysis package, PCR will be more robust. This guide has also addressed the usefulness of plotting data in different views for example, how the derivative melt curve plot can be used to pinpoint an amplicon T m, and how a difference plot can be used to accentuate differences between similar melt curves. The next step is to apply the technology to your specific research question. The Applications Appendix on page 2 provides several specific examples of how this technology can be used for the identification of gene variants. See the sidebar, Other Resources, on page 3 for additional resources. 19
20 5. Applications Appendix Methylation-Sensitive High-Resolution Melting Analysis on 75 Fast Real-Time PCR System Summary: Step-by-step description of a workflow for the locus-specific analysis of DNA methylation by methylation-sensitive high resolution melting (MS-HRM) on the Applied Biosystems 75 Fast Real-Time PCR System. Identifying Variants by High Resolution Melting (HRM) in Difficult Samples Summary: An example of single nucleotide polymorphism (SNP) genotyping using an HRM technique on formalin-fixed, paraffin-embedded (FFPE) tissues. The HRM v2. Software was used along with the 75 Fast Real-Time PCR System for genotyping of six DNA samples isolated from FFPE tissues. Results showed that the HRM Software used on the 75 System can be an effective tool to screen for unknown SNPs across genes of interest in this difficult-to-use tissue. Methylation Analysis Using Methylation Sensitive HRM and DNA Sequencing Summary: An application note describing the workflow for analysis of DNA methylation in specific loci by methylation-sensitive high resolution melting (MS-HRM) followed by DNA sequencing of the reaction products. The workflow relies on Applied Biosystems real-time PCR and capillary electrophoresis instruments and is supported by a comprehensive set of reagents and software tools. MS-HRM followed by Sanger-based DNA sequencing is a fast, simple method for methylation studies that can be manipulated to provide sensitivity for methylation levels as low as.1 2%. Analyzing Genetic Variation Using HRM Mutation Scanning Followed by Sanger Sequencing Summary: An application note outlining the detection of genomic variation using HRM mutation scanning followed by Sanger sequencing analysis. Because HRM analysis does not destroy samples, it is particularly well-suited for genetic variant scanning. The HRM process identifies samples for further study, and the PCR products can then be used as templates for DNA sequencing with minimal downstream processing. High Resolution Melting for Genotyping Applications Summary: An application note describing how HRM profiles can provide valuable information (GC content, length, sequence, and heterozygosity) for genotyping studies in addition to many other applications, including mutation screening and methylation analysis. 6. References 1. Reed GH, Kent JO, and Wittwer CT (27) High-resolution DNA melting analysis for simple and efficient molecular diagnostics, Pharmacogenomics 8(6): National Genetics Reference Laboratory (Wessex) Technology Assessment: Mutation scanning by high resolution melt analysis. Evaluation of RotorGene 6 (Corbett Life Science), HR1 and 384 well LightScanner (Idaho Technology) (June 26) National Genetics Reference Laboratory (Wessex) Salisbury District Hospital Salisbury SP2 8BJ, UK 3. Kent JO, Reed GH, Wittwer CT (27) Review: High-resolution DNA melting analysis for simple and efficient molecular diagnostics, Pharmacogenomics 8(6): von Ahsen N, Oellerich M, Schutz E (21) Limitations of genotyping based on amplicon melting temperature, Clin Chem 47: Graham R, Liew M, Lyon E, Meadows C, Wittwer CT (25) Distinguishing different DNA Heterozygotes by high-resolution melting, Clin Chem 51(7): Pornprasert S, Phusua A, Suanta S, Saetung R, Sanguansermsri T (28) Detection of alpha-thalassemia-1 Southeast Asian type using real-time gap-pcr with SYBR Green 1 and high resolution melting analysis. Eur J Haematol 8(6):51 514; and Price EP, Smith H, Huygens F, Giffard PM (27) High-Resolution DNA curve analysis of the clustered regularly interspaced short-palindronic-repeat locus of Campylobacter jejuni, Appl Environ Microbiol 73: For Research Use Only. Not for use in diagnostic procedures. 21 Life Technologies Corporation. All rights reserved. The trademarks mentioned herein are the property of Life Technologies Corporation or their respective owners. AmpliTaq, AmpliTaq Gold, and TaqMan are registered trademarks of Roche Molecular Systems, Inc. SYBR is a registered trademark and GreenER is a trademark of Molecular Probes, Inc. Printed in the USA. 1/21 Publication 117GU19-2 O Headquarters 85 Lincoln Centre Drive Foster City, CA 9444 USA Phone Toll Free International Sales For our office locations please call the division headquarters or refer to our Web site at /about/offices.cfm
Technical Note. Roche Applied Science. No. LC 18/2004. Assay Formats for Use in Real-Time PCR
Roche Applied Science Technical Note No. LC 18/2004 Purpose of this Note Assay Formats for Use in Real-Time PCR The LightCycler Instrument uses several detection channels to monitor the amplification of
Methylation Analysis Using Methylation-Sensitive HRM and DNA Sequencing
APPLICATION NOTE Methylation Analysis Using Methylation-Sensitive HRM and DNA Sequencing Methylation Analysis Using Methylation Sensitive HRM and DNA Sequencing Abstract DNA methylation is a key epigenetic
Essentials of Real Time PCR. About Sequence Detection Chemistries
Essentials of Real Time PCR About Real-Time PCR Assays Real-time Polymerase Chain Reaction (PCR) is the ability to monitor the progress of the PCR as it occurs (i.e., in real time). Data is therefore collected
Introduction To Real Time Quantitative PCR (qpcr)
Introduction To Real Time Quantitative PCR (qpcr) SABiosciences, A QIAGEN Company www.sabiosciences.com The Seminar Topics The advantages of qpcr versus conventional PCR Work flow & applications Factors
Highly specific and sensitive quantitation
PRODUCT ULLETIN SYR Select Master Mix SYR Select Master Mix Highly specific and sensitive quantitation SYR Select Master Mix offers advanced performance at an affordable price. SYR Select Master Mix is
Real-Time PCR Vs. Traditional PCR
Real-Time PCR Vs. Traditional PCR Description This tutorial will discuss the evolution of traditional PCR methods towards the use of Real-Time chemistry and instrumentation for accurate quantitation. Objectives
Troubleshooting Sequencing Data
Troubleshooting Sequencing Data Troubleshooting Sequencing Data No recognizable sequence (see page 7-10) Insufficient Quantitate the DNA. Increase the amount of DNA in the sequencing reactions. See page
Introduction to High Resolution Melt Analysis
Introduction to High Resolution Melt Analysis Contents Page Introduction 3 Overview of the Melting Profile Principle 3 The Intercalating Dye Non-saturating dyes Saturating dyes Release-on-demand dyes Instruments
LightCycler 480 Real-Time PCR System. High Resolution Melting: Optimization Strategies. Technical Note No. 1
LightCycler 480 Real-Time PCR System Technical Note No. 1 High Resolution Melting: Optimization Strategies High resolution melting (HRM) is a novel, closed-tube, post-pcr technique allowing genomic researchers
Real-time PCR: Understanding C t
APPLICATION NOTE Real-Time PCR Real-time PCR: Understanding C t Real-time PCR, also called quantitative PCR or qpcr, can provide a simple and elegant method for determining the amount of a target sequence
Application Guide... 2
Protocol for GenomePlex Whole Genome Amplification from Formalin-Fixed Parrafin-Embedded (FFPE) tissue Application Guide... 2 I. Description... 2 II. Product Components... 2 III. Materials to be Supplied
PATHOGEN DETECTION SYSTEMS BY REAL TIME PCR. Results Interpretation Guide
PATHOGEN DETECTION SYSTEMS BY REAL TIME PCR Results Interpretation Guide Pathogen Detection Systems by Real Time PCR Microbial offers real time PCR based systems for the detection of pathogenic bacteria
Stratagene QPCR Mouse Reference Total RNA
Stratagene QPCR Mouse Reference Total RNA Instruction Manual Catalog #750600 Revision C.0 For Research Use Only. Not for use in diagnostic procedures. 750600-12 LIMITED PRODUCT WARRANTY This warranty limits
2.500 Threshold. 2.000 1000e - 001. Threshold. Exponential phase. Cycle Number
application note Real-Time PCR: Understanding C T Real-Time PCR: Understanding C T 4.500 3.500 1000e + 001 4.000 3.000 1000e + 000 3.500 2.500 Threshold 3.000 2.000 1000e - 001 Rn 2500 Rn 1500 Rn 2000
Factors Influencing Multiplex Real-Time PCR
APPLICATION NOTE Multiplex Real-Time PCR Factors Influencing Multiplex Real-Time PCR Introduction Multiplex PCR is the simultaneous amplification of more than one target sequence in a single reaction [1].
TaqMan Fast Advanced Master Mix. Protocol
TaqMan Fast Advanced Master Mix Protocol For Research Use Only. Not intended for any animal or human therapeutic or diagnostic use. Information in this document is subject to change without notice. APPLIED
DNA Integrity Number (DIN) For the Assessment of Genomic DNA Samples in Real-Time Quantitative PCR (qpcr) Experiments
DNA Integrity Number () For the Assessment of Genomic DNA Samples in Real-Time Quantitative PCR (qpcr) Experiments Application Note Nucleic Acid Analysis Author Arunkumar Padmanaban Agilent Technologies,
amplification tech A Practical Guide to High Resolution Melt Analysis Genotyping
amplification tech note 6004 A Practical Guide to High Resolution Melt Analysis Genotyping Sean Taylor, Rachel Scott, Richard Kurtz, Carl Fisher, Viresh Patel, and Frank Bizouarn, Bio-Rad Laboratories,
RealStar HBV PCR Kit 1.0 11/2012
RealStar HBV PCR Kit 1.0 11/2012 RealStar HBV PCR Kit 1.0 For research use only! (RUO) Product No.: 201003 96 rxns INS-201000-GB-02 Store at -25 C... -15 C November 2012 altona Diagnostics GmbH Mörkenstraße
360 Master Mix. , and a supplementary 360 GC Enhancer.
Product Bulletin AmpliTaq Gold 360 Master Mix and 360 DNA Polymerase AmpliTaq Gold 360 Master Mix AmpliTaq Gold 360 DNA Polymerase 360 Coverage for a Full Range of Targets AmpliTaq Gold 360 Master Mix
QPCR Applications using Stratagene s Mx Real-Time PCR Platform
QPCR Applications using Stratagene s Mx Real-Time PCR Platform Dan Schoeffner, Ph.D Field Applications Scientist [email protected] Tech. Services 800-894-1304 Polymerase Chain Reaction Melt
SeqScape Software Version 2.5 Comprehensive Analysis Solution for Resequencing Applications
Product Bulletin Sequencing Software SeqScape Software Version 2.5 Comprehensive Analysis Solution for Resequencing Applications Comprehensive reference sequence handling Helps interpret the role of each
AxyPrep TM Mag PCR Clean-up Protocol
AxyPrep TM Mag PCR Clean-up Protocol Intro The AxyPrep Mag PCR Clean-up kit utilizes a unique paramagnetic bead technology for rapid, high-throughput purification of PCR amplicons. Using this kit, PCR
Technical Note. Roche Applied Science. No. LC 19/2004. Color Compensation
Roche Applied Science Technical Note No. LC 19/2004 Purpose of this Note Color The LightCycler System is able to simultaneously detect and analyze more than one color in each capillary. Due to overlap
Gene Expression Assays
APPLICATION NOTE TaqMan Gene Expression Assays A mpl i fic ationef ficienc yof TaqMan Gene Expression Assays Assays tested extensively for qpcr efficiency Key factors that affect efficiency Efficiency
National Genetics Reference Laboratory (Wessex) Technology Assessment. Mutation scanning by high resolution melt analysis.
National Genetics Reference Laboratory (Wessex) Technology Assessment Mutation scanning by high resolution melt analysis. Evaluation of Rotor Gene 6000 (Corbett Life Science), HR 1 and 384 well LightScanner
BacReady TM Multiplex PCR System
BacReady TM Multiplex PCR System Technical Manual No. 0191 Version 10112010 I Description.. 1 II Applications 2 III Key Features.. 2 IV Shipping and Storage. 2 V Simplified Procedures. 2 VI Detailed Experimental
Plexor Systems Instrument Setup and Data Analysis for the Applied Biosystems 7300 and 7500 Real-Time PCR Systems
Technical Manual Plexor Systems Instrument Setup and Data Analysis for the Applied Biosystems 7300 and 7500 Real-Time PCR Systems INSTRUCTIONS FOR USE OF PRODUCTS A4011, A4021, A4031, A4041, A4051 AND
Absolute Quantification Getting Started Guide
5 cdna Reverse Primer Oligo d(t) or random hexamer Synthesis of 1st cdna strand 3 5 cdna Applied Biosystems 7300/7500/7500 Fast Real-Time PCR System Absolute Quantification Getting Started Guide Introduction
Single Nucleotide Polymorphisms (SNPs)
Single Nucleotide Polymorphisms (SNPs) Additional Markers 13 core STR loci Obtain further information from additional markers: Y STRs Separating male samples Mitochondrial DNA Working with extremely degraded
Data Analysis for Ion Torrent Sequencing
IFU022 v140202 Research Use Only Instructions For Use Part III Data Analysis for Ion Torrent Sequencing MANUFACTURER: Multiplicom N.V. Galileilaan 18 2845 Niel Belgium Revision date: August 21, 2014 Page
DNA Sequencing Setup and Troubleshooting
DNA Sequencing Setup and Troubleshooting Lara Cullen, PhD Scientific Applications Specialist Australia and New Zealand Reviewing Sequencing Data Review the Electropherogram Review the Raw Data (Signal
TruSeq Custom Amplicon v1.5
Data Sheet: Targeted Resequencing TruSeq Custom Amplicon v1.5 A new and improved amplicon sequencing solution for interrogating custom regions of interest. Highlights Figure 1: TruSeq Custom Amplicon Workflow
DNA Sequence Analysis
DNA Sequence Analysis Two general kinds of analysis Screen for one of a set of known sequences Determine the sequence even if it is novel Screening for a known sequence usually involves an oligonucleotide
Quantifiler Human DNA Quantification Kit Quantifiler Y Human Male DNA Quantification Kit
Product Bulletin Human Identification Quantifiler Human DNA Quantification Kit Quantifiler Y Human Male DNA Quantification Kit The Quantifiler kits produce reliable and reproducible results, helping to
Sequencing Guidelines Adapted from ABI BigDye Terminator v3.1 Cycle Sequencing Kit and Roswell Park Cancer Institute Core Laboratory website
Biomolecular Core Facility AI Dupont Hospital for Children, Rockland Center One, Room 214 Core: (302) 651-6712, Office: (302) 651-6707, [email protected] Katia Sol-Church, Ph.D., Director Jennifer Frenck
Thermo Scientific DyNAmo cdna Synthesis Kit for qrt-pcr Technical Manual
Thermo Scientific DyNAmo cdna Synthesis Kit for qrt-pcr Technical Manual F- 470S 20 cdna synthesis reactions (20 µl each) F- 470L 100 cdna synthesis reactions (20 µl each) Table of contents 1. Description...
TaqMan Mutation Detection Assay
PROTOCOL TaqMan Mutation Detection Assay Competitive Allele-Specific TaqMan PCR Publication Part Number 4467011 Rev. B Revision Date April 2012 For Research Use Only. Not intended for any animal or human
Power SYBR Green PCR Master Mix and Power SYBR Green RT-PCR Reagents Kit
USER GUIDE Power SYBR Green PCR Master Mix and Power SYBR Green RT-PCR Reagents Kit Catalog Number 4368577, 4367659, 4367660, 4368706, 4368702, 4368708 (Master Mix) and 4368711 (RT-PCR Reagents Kit) Publication
LightCycler 480 Real-Time PCR System
Roche Applied Science LightCycler 480 Real-Time PCR System Planned introduction of the LightCycler 480 System: September 2005 Rapid by nature, accurate by design The LightCycler 480 Real-Time PCR System
Data Analysis on the ABI PRISM 7700 Sequence Detection System: Setting Baselines and Thresholds. Overview. Data Analysis Tutorial
Data Analysis on the ABI PRISM 7700 Sequence Detection System: Setting Baselines and Thresholds Overview In order for accuracy and precision to be optimal, the assay must be properly evaluated and a few
Reagent Guide. Applied Biosystems StepOne and StepOnePlus Real-Time PCR Systems
Reagent Guide Applied Biosystems StepOne and StepOnePlus Real-Time PCR Systems Applied Biosystems StepOne and StepOnePlus Real-Time PCR Systems Reagent Guide Copyright 2008, 2010 Applied Biosystems. All
SYBR Green Realtime PCR Master Mix -Plus-
Instruction manual SYBR Green Realtime PCR Master Mix -Plus- 0810 F0925K SYBR Green Realtime PCR Master Mix -Plus- Contents QPK-212T 1mLx1 QPK-212 1mLx5 Store at -20 C, protected from light [1] Introduction
Fluorescent dyes for use with the
Detection of Multiple Reporter Dyes in Real-time, On-line PCR Analysis with the LightCycler System Gregor Sagner, Cornelia Goldstein, and Rob van Miltenburg Roche Molecular Biochemicals, Penzberg, Germany
Getting Started Guide
Primer Express Software Version 3.0 Getting Started Guide Before You Begin Designing Primers and Probes for Quantification Assays Designing Primers and Probes for Allelic Discrimination Assays Ordering
Introduction. Preparation of Template DNA
Procedures and Recommendations for DNA Sequencing at the Plant-Microbe Genomics Facility Ohio State University Biological Sciences Building Room 420, 484 W. 12th Ave., Columbus OH 43210 Telephone: 614/247-6204;
PicoMaxx High Fidelity PCR System
PicoMaxx High Fidelity PCR System Instruction Manual Catalog #600420 (100 U), #600422 (500 U), and #600424 (1000 U) Revision C Research Use Only. Not for Use in Diagnostic Procedures. 600420-12 LIMITED
SYBR Green PCR Master Mix and SYBR Green RT-PCR Reagents Kit
USER GUIDE SYBR Green PCR Master Mix and SYBR Green RT-PCR Reagents Kit Catalog Number 4309155 (Master Mix) and 4306736 (RT-PCR Reagents Kit) Publication Part Number 4310251 Rev. G Revision Date September
Sequencing Library qpcr Quantification Guide
Sequencing Library qpcr Quantification Guide FOR RESEARCH USE ONLY Introduction 3 Quantification Workflow 4 Best Practices 5 Consumables and Equipment 6 Select Control Template 8 Dilute qpcr Control Template
A complete workflow for pharmacogenomics using the QuantStudio 12K Flex Real-Time
Application NOte QuantStudio 12K Flex Real-Time PCR System A complete workflow for pharmacogenomics using the QuantStudio 12K Flex Real-Time PCR System Introduction Pharmacogenomics (PGx) is the study
GenScript BloodReady TM Multiplex PCR System
GenScript BloodReady TM Multiplex PCR System Technical Manual No. 0174 Version 20040915 I Description.. 1 II Applications 2 III Key Features.. 2 IV Shipping and Storage. 2 V Simplified Procedures. 2 VI
Validating Microarray Data Using RT 2 Real-Time PCR Products
Validating Microarray Data Using RT 2 Real-Time PCR Products Introduction: Real-time PCR monitors the amount of amplicon as the reaction occurs. Usually, the amount of product is directly related to the
Protocol. Introduction to TaqMan and SYBR Green Chemistries for Real-Time PCR
Protocol Introduction to TaqMan and SYBR Green Chemistries for Real-Time PCR Copyright 2008, 2010 Applied Biosystems. All rights reserved. Ambion and Applied Biosystems products are for Research Use Only.
A guide to the analysis of KASP genotyping data using cluster plots
extraction sequencing genotyping extraction sequencing genotyping extraction sequencing genotyping extraction sequencing A guide to the analysis of KASP genotyping data using cluster plots Contents of
amplification tech Optical Design of CFX96 Real-Time PCR Detection System Eliminates the Requirement of a Passive Reference Dye
amplification tech note 6047 Optical Design of CFX96 Real-Time PCR Detection System Eliminates the Requirement of a Passive Reference Dye Liz Jordan and Richard Kurtz, Gene Expression Division, io-rad
DNA Sequencing Handbook
Genomics Core 147 Biotechnology Building Ithaca, New York 14853-2703 Phone: (607) 254-4857; Fax (607) 254-4847 Web: http://cores.lifesciences.cornell.edu/brcinfo/ Email: [email protected] DNA Sequencing
DNA Sequencing Troubleshooting Guide
DNA Sequencing Troubleshooting Guide Successful DNA Sequencing Read Peaks are well formed and separated with good quality scores. There is a small area at the beginning of the run before the chemistry
Aurora Forensic Sample Clean-up Protocol
Aurora Forensic Sample Clean-up Protocol 106-0008-BA-D 2015 Boreal Genomics, Inc. All rights reserved. All trademarks are property of their owners. http://www.borealgenomics.com [email protected]
Real-time quantitative RT -PCR (Taqman)
Real-time quantitative RT -PCR (Taqman) Author: SC, Patti Lab, 3/03 This is performed as a 2-step reaction: 1. cdna synthesis from DNase 1-treated total RNA 2. PCR 1. cdna synthesis (Advantage RT-for-PCR
quantitative real-time PCR, grain, simplex DNA extraction: PGS0426 RT-PCR: PGS0494 & PGS0476
BioScience quantitative real-time PCR, grain, simplex DNA extraction: PGS0426 RT-PCR: PGS0494 & PGS0476 This method describes a Real-time semi-quantitative TaqMan PCR procedure for the determination of
Real-time PCR handbook
Real-time PCR handbook Single-tube assays 96- and 384-well plates 384-well TaqMan Array cards OpenArray plates The image on this cover is of an OpenArray plate which is primarily used for mid-density real-time
DNA Core Facility: DNA Sequencing Guide
DNA Core Facility: DNA Sequencing Guide University of Missouri-Columbia 216 Life Sciences Center Columbia, MO 65211 http://biotech.missouri.edu/dnacore/ Table of Contents 1. Evaluating Sequencing Data..
Application Note. Biotechnology Explorer Crime Scene Investigator PCR Basics. Kit: A Real-Time PCR Extension
Biotechnology Explorer Crime Scene Investigator PCR Basics Kit: Table of Contents Introduction.............................................. 2 Learning Objectives......................................
Accurate and sensitive mutation detection and quantitation using TaqMan Mutation Detection Assays for disease research
PPLICTION NOTE Mutation Detection ssays ccurate and sensitive mutation detection and quantitation using Mutation Detection ssays for disease research In this research study, we addressed the feasibility
ab185916 Hi-Fi cdna Synthesis Kit
ab185916 Hi-Fi cdna Synthesis Kit Instructions for Use For cdna synthesis from various RNA samples This product is for research use only and is not intended for diagnostic use. Version 1 Last Updated 1
qpcr Quantification Protocol Guide
qpcr Quantification Protocol Guide FOR RESEARCH USE ONLY Topics 3 Introduction 5 User-Supplied Consumables and Equipment 7 Select Template 8 Dilute qpcr Template 9 Dilute Libraries 10 Prepare Reaction
TaqMan Genotyper Software v1.0.1 TaqMan Genotyping Data Analysis Software
TaqMan Genotyper Software v1.0.1 TaqMan Genotyping Data Analysis Software March 2011 Product Overview TaqMan Genotyper Software TaqMan Genotyper Software Standalone data analysis software for Applied Biosystems
Quantitative Real Time PCR Protocol. Stack Lab
Quantitative Real Time PCR Protocol Stack Lab Overview Real-time quantitative polymerase chain reaction (qpcr) differs from regular PCR by including in the reaction fluorescent reporter molecules that
Real-time qpcr Assay Design Software www.qpcrdesign.com
Real-time qpcr Assay Design Software www.qpcrdesign.com Your Blueprint For Success Informational Guide 2199 South McDowell Blvd Petaluma, CA 94954-6904 USA 1.800.GENOME.1(436.6631) 1.415.883.8400 1.415.883.8488
Real time and Quantitative (RTAQ) PCR. so I have an outlier and I want to see if it really is changed
Real time and Quantitative (RTAQ) PCR or.. for this audience so I have an outlier and I want to see if it really is changed Nigel Walker, Ph.D. Laboratory of Computational Biology and Risk Analysis, Environmental
Beginner s Guide to Real-Time PCR
Beginner s Guide to Real-Time PCR 02 Real-time PCR basic principles PCR or the Polymerase Chain Reaction has become the cornerstone of modern molecular biology the world over. Real-time PCR is an advanced
All-in-One mirna qrt-pcr Reagent Kits For quantitative detection of mature mirna
All-in-One mirna qrt-pcr Reagent Kits For quantitative detection of mature mirna All-in-One TM mirna First-Strand cdna Synthesis Kit AMRT-0020 (20 RT reactions), AMRT-0060 (60 RT reactions) Used in combination
DNA Detection. Chapter 13
DNA Detection Chapter 13 Detecting DNA molecules Once you have your DNA separated by size Now you need to be able to visualize the DNA on the gel somehow Original techniques: Radioactive label, silver
Development of a Workflow to Detect Sequence Variants in the BRCA1 and BRCA2 Genes
Your Innovative Research BRCA1 and BRCA2 Variant Detection Development of a Workflow to Detect Sequence Variants in the BRCA1 and BRCA2 Genes The oncogenetics group in the DNA Diagnostics division of the
Path-ID Multiplex One-Step RT-PCR Kit
USER GUIDE Path-ID Multiplex One-Step RT-PCR Kit TaqMan probe-based multiplex one-step real-time RT-PCR detection of RNA targets Catalog Numbers 4428206, 4428207, 4440022 Publication Part Number 4440907
PreciseTM Whitepaper
Precise TM Whitepaper Introduction LIMITATIONS OF EXISTING RNA-SEQ METHODS Correctly designed gene expression studies require large numbers of samples, accurate results and low analysis costs. Analysis
Procedures For DNA Sequencing
Procedures For DNA Sequencing Plant-Microbe Genomics Facility (PMGF) Ohio State University 420 Biological Sciences Building 484 W. 12th Ave., Columbus OH 43210 Telephone: 614/247-6204 FAX: 614/292-6337
DNA SEQUENCING SANGER: TECHNICALS SOLUTIONS GUIDE
DNA SEQUENCING SANGER: TECHNICALS SOLUTIONS GUIDE We recommend for the sequence visualization the use of software that allows the examination of raw data in order to determine quantitatively how good has
CompleteⅡ 1st strand cdna Synthesis Kit
Instruction Manual CompleteⅡ 1st strand cdna Synthesis Kit Catalog # GM30401, GM30402 Green Mountain Biosystems. LLC Web: www.greenmountainbio.com Tel: 800-942-1160 Sales: Sales@ greenmountainbio.com Support:
Epstein Barr Virus (Human Herpes virus 4) genesig Standard Kit. DNA testing. Everything... Everyone... Everywhere...
TM Primerdesign Ltd TM Primerdesign Ltd Epstein Barr Virus (Human Herpes virus 4) nonglycosylated membrane protein (BNRF1) gene genesig Standard Kit 150 tests DNA testing Everything... Everyone... Everywhere...
Optimizing and Analyzing Real-Time Assays on the SmartCycler II System
Optimizing and Analyzing Real-Time Assays on the SmartCycler II System Cepheid Technical Support Overview This technical note provides guidelines on transferring, optimizing, and evaluating real-time PCR
Forensic DNA Testing Terminology
Forensic DNA Testing Terminology ABI 310 Genetic Analyzer a capillary electrophoresis instrument used by forensic DNA laboratories to separate short tandem repeat (STR) loci on the basis of their size.
RevertAid Premium First Strand cdna Synthesis Kit
RevertAid Premium First Strand cdna Synthesis Kit #K1651, #K1652 CERTIFICATE OF ANALYSIS #K1651 Lot QUALITY CONTROL RT-PCR using 100 fg of control GAPDH RNA and GAPDH control primers generated a prominent
ChIP TROUBLESHOOTING TIPS
ChIP TROUBLESHOOTING TIPS Creative Diagnostics Abstract ChIP dissects the spatial and temporal dynamics of the interactions between chromatin and its associated factors CD Creative Diagnostics info@creative-
PCR and Sequencing Reaction Clean-Up Kit (Magnetic Bead System) 50 preps Product #60200
3430 Schmon Parkway Thorold, ON, Canada L2V 4Y6 Phone: 866-667-4362 (905) 227-8848 Fax: (905) 227-1061 Email: [email protected] PCR and Sequencing Reaction Clean-Up Kit (Magnetic Bead System)
Single-Cell DNA Sequencing with the C 1. Single-Cell Auto Prep System. Reveal hidden populations and genetic diversity within complex samples
DATA Sheet Single-Cell DNA Sequencing with the C 1 Single-Cell Auto Prep System Reveal hidden populations and genetic diversity within complex samples Single-cell sensitivity Discover and detect SNPs,
How To Get Rid Of Small Dna Fragments
AxyPrep TM Mag FragmentSelect-I Protocol (Fragment Size Selection for Illumina Genome Analyzer and Life Technologies SoLiD) Introduction The AxyPrep Mag FragmentSelect-I purification kit utilizes a unique
AffinityScript QPCR cdna Synthesis Kit
AffinityScript QPCR cdna Synthesis Kit INSTRUCTION MANUAL Catalog #600559 Revision C.01 For In Vitro Use Only 600559-12 LIMITED PRODUCT WARRANTY This warranty limits our liability to replacement of this
Fast SYBR Green Master Mix. Protocol
Fast SYBR Green Master Mix Protocol Copyright 2007, 2010 Applied Biosystems. All rights reserved. For Research Use Only. Not for use in diagnostic procedures. Information in this document is subject to
Introduction to Quantitative PCR
Introduction to Quantitative PCR Methods and Applications Guide Introduction to Quantitative PCR Methods and Applications Guide IN 70200 D US and Canada Orders: 800-227-9770 x3 Technical Service: 800-227-9770
FOR REFERENCE PURPOSES
BIOO LIFE SCIENCE PRODUCTS FOR REFERENCE PURPOSES This manual is for Reference Purposes Only. DO NOT use this protocol to run your assays. Periodically, optimizations and revisions are made to the kit
VLLM0421c Medical Microbiology I, practical sessions. Protocol to topic J10
Topic J10+11: Molecular-biological methods + Clinical virology I (hepatitis A, B & C, HIV) To study: PCR, ELISA, your own notes from serology reactions Task J10/1: DNA isolation of the etiological agent
Applications Guide. Real-Time PCR Applications Guide
Applications Guide Real-Time PCR Applications Guide table of contents Table of Contents 1. Overview of Real-Time PCR 2 1.1 Key Concepts of Real-Time PCR 2 1.1.1 What Is Real-Time PCR? 2 1.1.2 How Real-Time
StepOne and StepOnePlus Real-Time PCR Systems. Remarkably Simple Systems. Simply Remarkable Results.
StepOne and StepOnePlus Real-Time PCR Systems Remarkably Simple Systems. Simply Remarkable Results. Step Up to High-Performance Real-Time PCR Remarkably Simple Systems Applied Biosystems, a leader in technology
Multiplex your most important
Multiplex your most important genetic assays on one platform GenomeLab GeXP Genetic Analysis System Blood Banking Capillary Electrophoresis Centrifugation Flow Cytometry Genomics Lab Automation Lab Tools
Single-Cell Whole Genome Sequencing on the C1 System: a Performance Evaluation
PN 100-9879 A1 TECHNICAL NOTE Single-Cell Whole Genome Sequencing on the C1 System: a Performance Evaluation Introduction Cancer is a dynamic evolutionary process of which intratumor genetic and phenotypic
SEQUENCING. From Sample to Sequence-Ready
SEQUENCING From Sample to Sequence-Ready ACCESS ARRAY SYSTEM HIGH-QUALITY LIBRARIES, NOT ONCE, BUT EVERY TIME The highest-quality amplicons more sensitive, accurate, and specific Full support for all major
The Power of Next-Generation Sequencing in Your Hands On the Path towards Diagnostics
The Power of Next-Generation Sequencing in Your Hands On the Path towards Diagnostics The GS Junior System The Power of Next-Generation Sequencing on Your Benchtop Proven technology: Uses the same long