Drayton Digistat +2RF/+3RF



Similar documents
Programmable Room Thermostat 7 Day (5-2 Day) Models: / Power Supply: Battery / Mains

Drayton Digistat +2RF

TRANSMITTER RECEIVER THESE INSTRUCTIONS APPLY IN THE UK ONLY THESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER OR AT THE APPLIANCE. Digistat Optimiser

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

Wireless 7 Day Programmable Room Thermostat

CM702 PROGRAMMABLE THERMOSTAT FEATURES PRODUCT SPECIFICATION SHEET

User Manual THR840DUK Digital Thermostat

Installation Guide for Hive Active Heating

Installation & User Instructions

IN-OUT Thermometer with Cable Free Sensor and Clock

VIESMANN. Installation and service instructions VITOTROL 100. for contractors

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

COMPUTHERM Q7 Programmable, digital room thermostat. Operating Instructions

Owner s Guide Guide du propriétaire Guía para el usuario TH115-AF-GB-10. Programmable thermostat Thermostat programmable Termostato programable

Digistat RF Troubleshooting Procedure

Manual & Technical Documentation V1.1

Alpha Climatic Programmable Modulating Boiler Energy Manager. Installation and User Instructions

Table of Contents. Introduction. Radio Frequency Control. Initial setup Setting the time. Setting the temperature

CM921 - User Guide. Description. Features. 1 day Wireless Programmable Room Thermostat with LoT technology WHAT IS A PROGRAMMABLE ROOM THERMOSTAT?

TYXIA. * _Rev.1* Installation and User Guide. Wireless receiver. TYXIA RF channel

SET1E. Installation & User Instructions. Electronic timeswitch for heating & hot water. Certification Mark

evohome Wireless Radiator Zoning Kit Installation & User Guide

Wireless Thermostats 230v and Battery Operated Instruction Manual

Product and functional description

AN500T, AN1000, AN1000T, AN1500, AN1500T AN2000, AN2000T

QFP910. Water detector. Building Technologies. CE1N2732en. Synco living

DUAL SENSING DIGITAL THERMOSTAT PRODUCT INSTRUCTIONS. Construction Automotive Industry

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

CR Band Auto Set Dual Alarm Clock Radio ROBERTS. Sound for Generations. Please read this manual before use

Fused Spur Time Switch

RF 1. Contents: Connecting diagram. Detailed information:

Product and Application Description

DT92 WIRELESS DIGITAL ROOM THERMOSTAT FEATURES PRODUCT SPECIFICATION SHEET

LCD Display. Function keys. Stand. Adapter socket

Nest Learning Thermostat Installation Guide. Installation step-by-step

BARDIC. 4 & 8 Zone Fire Panels Zircon range. Data, installation, operation and maintenance. by Honeywell

EVC40 EMERGENCY VOICE COMMUNICATION SYSTEM

Operating instructions for built-in electronic timers with Day and Week programms. Series 884

OPERATING INSTRUCTIONS

HERZ-Thermal Actuators

CM927 WIRELESS PROGRAMMABLE THERMOSTAT FEATURES PRODUCT SPECIFICATION SHEET

Installation Guide. DEVIreg 530. Electronic Thermostat.

DS DRTE. AIR ROOM TEMPERATURE SENSOR with fan speed control switches

THERMONET UNDERFLOOR HEATING STANDARD THERMOSTAT KIT STOCK CODE 5260

Operating Instructions. Room temperature controller

GB/DAS User Instruction

KD-204. Telephone Remote Switch. Operating Instructions

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

RUST ELECTRONICS LTD. Remote Switching Unit RCU-O4

Stove Guard Kit User Manual

Power Socket (2 Gang)

4.3-inch Back-Up Camera

TIG INVERTER INSTRUCTION MANUAL

Bathroom Cabinet. Installation & User Guide. Illuminated Mirrors.

Transmitter Speed. Instructions for use Betriebsanleitung Mode d emploi Instrucciones para el uso Istruzioni per l uso

MCR1900 Media Converter 19-Slot Chassis

MAKING MODERN LIVING POSSIBLE. living connect. Installation and User Guide. Danfoss Heating Solutions

Heating Controller. Building Technologies HVAC Products

LED Security Spotlight User Manual

QFP910. Water detector. Building Technologies. CE1N2732en Synco living

OZW30. Central Unit SYNERGYR

HMI display Installation Guide

Adjustable room thermostat for heating only or cooling only systems

Vroom Hardware manual ver Code 114VROOHWE00. Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR

2013 Wireless Video Intercom INSTALLATION GUIDE

T0118 T2118 T3118. Instruction Manual

Operating Instructions DT, PRT, PRT/HW PRT-R, PRT-R2

MAKING MODERN LIVING POSSIBLE. living connect. Installation and User Guide. Danfoss heating

ST Series POWER SUPPLIES USER INSTRUCTIONS

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

Wireless Home Security Alarm System AM 500

EBDSPIR-PRM, EBDSPIR-PRM-IP

T7560A,B,C Digital Wall Module

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

ES-LCD User Control SD Card Location

Introduction. Refrigerant Leak Detecting System. Feature and Benefits

DAB+ / FM Tuner Model: TU-201

Processor. Installation Guide

MOUNTING AND OPERATING INSTRUCTIONS

RRV934. Multi-controller. Synco living

SET3M. electro-mechanical 24 programmer for heating & hot water. Installation & User Instructions

Mitel DECT Base Stations

Table of Contents. 1 - Specifications Installation Wiring User controls...7

VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODELS:

RVL470. Heating Controller. Building Technologies HVAC Products. Series B

FIREDEX Conventional Fire Panels

CM927 - User Guide. Description. Features. 7 day Wireless Programmable Room Thermostat with LoT Technology WHAT IS A PROGRAMMABLE ROOM THERMOSTAT?

TP5000 Si Range Electronic 5/2 day programmable room thermostat Mains, Battery and RF versions Installation and User Instructions

Instruction Manual for Operating Panel 301 and 302

INSTRUCTION MANUAL CIRRO MK 3/TYPE 2 MIST GENERATOR

INPUT/OUTPUT MODULE CONVERT INPUTS AND OUTPUTS TO WIRELESS

FAQs. Conserve package. Gateway... 2 Range Extender... 3 Smart Plug... 3 Thermostat... 4 Website... 7 App and Mobile Devices... 7

Rain+Birdt. Simple To Set Timer (SST) Setup & Operation Instructions. English RAIN BIRD ( ) or visit

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

REB 1 REB 3 REB 5 REB 6 REB 8 REB 10 REB 12 REB 16

ACS-30-EU-EMDR-10-MOD

RADIO CONTROLLED DIGITAL CLOCK MODELS / 88906

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

Transcription:

/+3RF Programmable Room Thermostat Wireless Model: RF700/22090 Model: RF701/22092 Power Supply: Battery - Thermostat Mains - Digistat SCR Invensys Controls Europe Customer Service Tel: 0845 130 5522 Customer Service Fax: 0845 130 0622 Technical Helpline Tel: 0845 130 7722 Website: www.draytoncontrols.co.uk Email: customer.care@invensyscontrols.com User Guide 06490099001 IssA Certification Mark

Hol Man Auto Day Installation Instructions WARNING If you do not have the knowledge to install the SCR safely then you must arrange for a competent electrician to install it for you. Wiring must conform to the current IEE regulations. Prior to commencing the installation you must ensure the mains supply is switched off. INSTALLATION OF SCR RECEIVER Read all installation and commissioning instructions before proceeding. Do not switch on until ready to commission. The system wiring must be able to be fully disconnected from the mains supply by a switch incorporated in the fixed wiring having a contact separation of at least 3mm on both poles. Fused at 3A. ON RECEIVE / ALARM OVERRIDE 2 1 LEARN MODE LOCATION The Digistat SCR (receiver) should be mounted in a convenient position, close to the boiler or central heating system. For the best performance install in an open space, at least 30cm distance from any metal objects including wall boxes and boiler housing. It is recommended that the SCR is mounted on the wall nearest the final location of the Digistat+RF programmable room thermostat and not less than 30cm from the boiler side panel. Warning: Installing the SCR too close to the metal side panel or mains cables may interfere with the radio signal. 30cm Min BOILER Radio Signal Range: 30m Typically The range may be affected by composition/density and number of walls between the Digistat +RF and SCR Preferred side of boiler

FIXING (minimum wall plate clearances shown) 1. Loosen the securing screws, remove the wallplate, and if surface wiring is to be used, snap out the cable entry strip on the bottom edge of the wallplate with a pair of pliers. 2. Fix the wallplate, terminals at the top, either direct onto the flat wall using wall plugs and no 6 x1 wood screws or on a plastic flush mounting single conduit box using M3.5 x 14 screws. Minimum wallplate clearances are shown. 3. Complete the wiring to the SCR wallplate in accordance with the relevant diagram, to comply with current IEE regulations. 4. Place the SCR onto the wallplate and tighten the securing screws. SCR wallplate clearances 50 mm minimum clearance N L 1 2 3 4 40 mm minimum clearance 40 mm minimum clearance 70 mm minimum clearance Electrical Volt free contacts N L 1 2 3 230V ac 50Hz Fused 3A Common heating satisfied or call for cooling Call for heat This product is double insulated and does not require an earth connection. The SCR should be wired to the boiler or central heating wiring using the correct type of cable or flex. The SCR should be wired in to replace hard wired room or programmable thermostats shown on the system or boiler wiring diagrams. Always check other manufacturers instructions for compatibility.

Hol Man Auto Day Hol Man Auto Day Combi boiler basic wiring layout ac Zone control basic wiring layout ac Note: If the or +3RF is used without a separate programmer, or the programmer is set constantly on it would be acceptable to link L to 1 provided the output voltage required is 230V ac.

COMMISSIONING THE DIGISTAT +2RF or +3RF WIRELESS SYSTEM 1. Turn off the power supply to the Digistat SCR (receiver unit) and leave for 5 seconds. 2. Turn on power to SCR unit and check red light is on. 3. Press override button No.2 and check the green light comes on and boiler fires. 4. Press & hold down button No.1 (Keep depressed), then press No.2 and keep depressed. {The Red LED light will flash a couple of times and then it will go out} 5. Now release both the buttons {the two LED lights should come back on} 6. Get the Digistat+2RF/+3RF unit and stand two metres away from the SCR unit with the Digistat+2RF/+3RF unit in your hand. 7. Remove the battery cover and fit the batteries. 8. The Red LED light on the SCR will now flash for approx. 7 seconds. 9. This confirms that the radio signal is being sent and received. 10. The Digistat+2RF/+3RF and the SCR are now successfully linked by a dedicated RF address. 11. Install the Digistat+2RF/+3RF as follows: IMPORTANT: MULTIZONE INSTALLATIONS ONLY If more than one wireless system is fitted within the same property ie. for controlling 2 or more zones (multi-zone) it is essential that the Digistat +RF units are matched correctly to the relevant SCR. This is easily achieved by commissioning each Digistat +RF and SCR in turn. I

INSTALLATION OF THE DIGISTAT +2RF or +3RF PROGRAMMABLE THERMOSTAT Hol Man Auto Day Location The /+3RF is a radio frequency device and for best performance should be mounted in an open space, not less than 30cm distance from any metal objects, including wall boxes. Care should be taken to mount the /+3RF on a wall, in a postion which is not subject to direct sunlight or draughts. Preferably it should be mounted on an inside wall about 1.5m (5ft) above the floor in a position where it can respond to room temperature, but away from the direct influence of radiators or other appliances giving off heat. Signal Strength Before fixing the /+3RF to the wall it is recommended to first check the signal strength from that location. To do this, remove the batteries, press and hold the + button whilst refitting the batteries. The display now shows rf which indicates that the /+3RF is continuously sending an OFF signal to the SCR (receiver). Leave the /+3RF in position and return to view the SCR. If the RED LED is continuously flashing, this indicates a good signal. If the RED LED is not flashing, this indicates a poor signal and you need to reposition the /+3RF until the RED LED is flashing. When the signal strength has been confirmed remove the batteries to cancel the test and follow the installation instructions 1-7 as follows.

Installation 1. Remove the front cover using a flat screwdriver and separate from back plate (Fig 1). (Fig 1) 2. Fix the back plate directly onto the wall using suitable wall plugs and screws (Fig 2). (Fig 2) 3. Replace the front cover by locating in position and pushing fully onto the back cover (Fig 3). (Fig 3) 4. Remove the battery cover using a coin (Fig 4). 5. Install the 2 AA batteries provided (Fig 5). Drayto n Drayto n (Fig 4) (Fig 5) 6. Replace battery cover (fig 6). Drayto n Drayto n (Fig 6) 7. The /+3RF is now installed and will automatically start to control the room temperature according to the pre-set program 1 as shown in the User Guide. The display shows the correct time and date which is automatically set together with the actual room temperature.

INSTALLER OPTIONS If you wish to change any of the Installer Options as shown below, enter the Installer Option Menu from Auto mode by pressing < and + simultaneously for 5 seconds. Pressing < and + again for 5 seconds will exit the Menu and return to Auto mode. Once the Installer Options screen has been selected (Fig 7), the < and > buttons allow you to scroll through the Menu (shown below). The + and - allow you to change values. Once a value has been changed pressing > before exiting the Menu will save the new setting. (Fig 8 shows Option 02 OFF). (Fig 7) (Fig 8) Installer Options What is it Select between Default 02 Freeze Protection On Off On 04 Low Set Point C 5 High Limit 5 05 High Set Point C Low Limit 32 32 06 Delayed Start (Energy saving feature) On Off Off 10 Valve Protection On Off Off 11 Valve Protection Time (Mins) 1 5 3 (Option 02) Freeze Protection Freeze protection will switch on the heating if the room temperature falls to 5ºC and will then control the temperature at 7ºC even if the Digistat+2RF/+3RF is in OFF mode. The Freeze Protection default in ON. To switch off the Freeze Protection mode enter the Installer Options Menu (Refer to Installer Options 02) and change to OFF. Press > to accept. (Option 04 & 05) Low and High Limit set points. The user temperature set points defaults are High 32ºC and Low 5ºC, to change these limits enter the Installer Options Menu (Refer to Installer Options 04 & 05). (Option 06) Intelligent Delayed Start (Energy saving feature). The Intelligent Delayed Start is an energy saving feature which automatically reduces the warm up time for the heating system. As the weather becomes milder, Intelligent Start will delay the heating start times so that fuel is not wasted bringing the room up to temperature earlier than necessary. Note: Intelligent Delayed Start only applies in Auto mode. Intelligent Delayed Start default is in OFF mode. To switch ON Intelligent Delayed Start enter the Installer Options Menu (Refer to Installer Options 06). Note the Intelligent Delayed start option is not suitable for Hydronic underfloor application. Ensure Installer option 06 is set to OFF before final commissioning for Hydronic underfloor application. S

Special Note: If the Intelligent delayed start feature is enabled, (Off changed to On in Installer option 06), please inform the end user of this feature. The following special note has been added to the user instruction to explain the adjustment requirement: When the delay period is operating indicated by the flame symbol flashing (Fig12), pressing any button returns the Digistat +2/3RF to auto mode allowing normal button operation until the next time/ temperature event, when it will resume the delay start mode or follows the Holiday, Manual, Override or Off modes as selected. Changes to the installer options and pre-set programmes must be made with the flame symbol not flashing. (Fig 12) (Option 10) Valve Protection In some hydronic heating systems there may be a requirement to protect the valve by operating it once a day, for a given period, without bringing on the heating system. If valve protection is selected the valve will be operated for a period as shown in Valve protection time (mins). Valve protection time every day at 10.00am. Valve protection default is OFF. To enable the valve protection mode enter the Installer Options Menu (Refer to Installer Option 10). (Option 11) Valve Protection time (mins). Valve protection time can be set between 1 and 5 minutes (default 3 minutes). To change this once a day on time enter the Installer Options Menu (Refer to Installer Option 11). Digistat +RF Programmable Room Thermostats are available in 2 models. = 24 Hour, Programs are the same every day (Monday to Sunday) Digistat +3RF = 5-2 day / 7day, allows you to set programs for week days and weekends or different programs for every day of the week. D

Display Error code E1 When the display shows an error code (E1) this indicates a sensor fault and the heating system will remain Off. Please contact your local heating service engineer to replace your /3RF. Technical Data /+3RF Power supply 2 X 1.5V IEC LR6 (AA) alkaline batteries Battery life 2 years typical Ambient temperature Operating 0 C to 40 C Storage 20 C to 55 C Ambient humidity Operating 25% to 90% (non condensing) Storage 15% to 95% Temperature range 5 C to 32 C Accuracy (between 5 C & 32 C) 0.5K Timing resolution 1 minute Temperature resolution 0.5K Ball pressure test 75 C Pollution situation Degree 2 Protection level IP30 T

Technical Data SCR (Receiver) Applicable Standards: Power Supply: Switch Type & Rating: Wiring: Reception Frequency: BS EN60730-1 BS EN60730-2-7 BS EN60730-2-9 ETSI EN 300 220-3 Electromagnetic compatibility and radio spectrum Matters (ERM); Short Range Devices (SRD). ETSI EN 301 489-3 Electromagnetic compatibility and radio spectrum Matters (ERM); EMC standard for radio equipment and services; Part 3: Specific conditions for Short Range Devices (SRD) operating on frequencies between 6 khz and 40 GHz. 73/23/EEC Low Voltage Directive 89/336/EEC EMC Directive 93/68/EEC Marking Directive 1999/5/EC R&TTE Directive 230V ac 50Hz SPDT (voltage free) 2(1)A 230V ac or 24V ac/dc Designed for fixed wiring only, to comply with current IEE regulations. 433 MHz Dimensions 96.5 Hol Man Auto Day 137.0 31.3