SenTix 950 SenTix 980



Similar documents
USEPA Electrode Method Method 8156

DISSOLVED OXYGEN PROBE

Direct ISE Method Method to 1000 mg/l Na + Sodium ISE

ph Measurement and Control

Nitrogen, Ammonia. Known Addition ISE Method 1 Method Minimum of 0.8 mg/l NH 3 N. Ammonia ISE. Test preparation. Instrument-specific table

Measurement by Ion Selective Electrodes

Measuring ph in Water or CaCl2 Using a ph Meter. Compiled by Darren Murray, June 30, 2011 TABLE OF CONTENTS OVERVIEW 3

ExStik TM ph Waterproof Meters

Milwaukee USER MANUAL. Milwaukee. Smart DO Meter PORTABLE DISSOLVED OXYGEN METER MODEL: SM600. Authorized Dealer: ISMIL600 11/01

Milwaukee USER MANUAL

User Guide. ExStik TM ph (PH100 & PH110) and ORP (RE300) Waterproof Series Pens. Patent Pending

AIRMoN, ph and Conductivity Field Measurement

Operating manual. ph ph meter

User Guide. Heavy Duty Dissolved Oxygen Meter. Model

Care and use guide. Contents. a handy solution made easy. page

REDOX AND REFERENCE ELECTRODE USER MANUAL

OPERATION MANUAL. Pen type, separate electrode SOIL PH METER Model : PH-220S

ELECTROCHEMISTRY. BOECO ELECTRODES The electrodes are not included with the ph meters and have to be ordered separately:

Operating Instructions

Experiment 4 (Future - Lab needs an unknown)

Operating manual. ba75441e. inolab ph/cond 720. Measuring Instrument for ph, Redox, and Conductivity

Operating manual. Multi 340i. mg/l. ARng. ph/dissolved Oxygen/Conductivity Measuring Instrument. ba52318e02 03/2004

Operating manual. ph/cond 3400i. Tref25 nlf C TP CAL. ph/conductivity measuring instrument. ba75687e01 01/2007

Resolution selectable from 0.01 and ph. Range ph. Accuracy ± ph

ph and Acidity in Wine and Fruit Juice

Cadmium Reduction Method Method to 30.0 mg/l NO 3 N (HR) Powder Pillows or AccuVac Ampuls

Direct Measurement Method Method to 20.0 mg/l (or 0 to 200% saturation) O 2 Clark-type Amperometric Sensor

ELECTROCHEMISTRY. Theory and Practice

Dissolved Oxygen Sensors

15. Acid-Base Titration. Discover the concentration of an unknown acid solution using acid-base titration.

MODEL 430 PORTABLE ph/conductivity METER OPERATING MANUAL

Operating manual. ph ph meter. ba75791e02 11/2008

PRETREATMENT TECHNICAL DATA SHEET WATER EMULSIFIABLE RUST PREVENTATIVE PRODUCT DESCRIPTION

Operator Quick Guide EC SENSOR

PROCEDURE COVERSHEET. Document Section: CHEMISTRY Author: JOANNE WONG Date Authored: JAN In Use Date: 2/1/2011 Discontinued Date:

Color, True and Apparent

OxyGuard. Dissolved Oxygen Probe

JUMO BlackLine CR-GT/-EC/-GS Conductive 2-Electrode Conductivity Sensor

Operating manual. ph 7310 ph 7310P. Printermodul. ph 7310P. ph ph meter

1. To perform a potentiometric titration of a sample of Liquid Drano with hydrochloric acid.

Phosphorus, Reactive (Orthophosphate)

Color, True and Apparent

Compact ph Measuring Instruments

ph 200 ph-/redox-/temperature Meter Operating instructions

HND-R. Hand-held ph, Redox and Temperature Measuring Units

UltraBasic Benchtop ph Meter Operation Manual

ph Sensor Model 397 CAUTION SENSOR/PROCESS APPLICATION COMPATIBILITY WARNING ATEX DIRECTIVE Instruction Sheet PN 51A-397/rev.

Features, Limitations & Potential Errors

USEPA 1 FerroVer Method 2 Method to 3.00 mg/l Fe Powder Pillows or AccuVac Ampuls

Acid Base Titrations

OPERATING MANUAL. ba77053d01 02/ C :37 USB output. Multi 3320 METER FOR 2 SENSORS (PH/ORP/D.O./COND)

18 Conductometric Titration

Related concepts Kohlrausch s law, equivalent conductivity, temperature dependence of conductivity, Ostwald s dilution law.

User's Manual. Heavy Duty Dissolved Oxygen Meter Model

ph and Acidity in Tomato Sauce

In this experiment, we will use three properties to identify a liquid substance: solubility, density and boiling point..

PART I SIEVE ANALYSIS OF MATERIAL RETAINED ON THE 425 M (NO. 40) SIEVE

To see how this data can be used, follow the titration of hydrofluoric acid against sodium hydroxide below. HF (aq) + NaOH (aq) H2O (l) + NaF (aq)

SINGLE RANGE DS METERS Operation Instructions

Bluelab Soil ph Meter Instruction Manual

Turb 550 / Turb 550 IR

Solids, Volatile Dissolved and Fixed Dissolved

Hygro-Thermometer + InfraRed Thermometer Model RH101

Care and use guide. Contents. page

Measuring the Conductivity of Pure Water Using USP<645>

Shampoo Properties Evaluation General Science

LZV585 (B) The 1-cm path is aligned with the arrow on the adapter

6 H2O + 6 CO 2 (g) + energy

Ion Selective Electrodes

Nokia Charging Connectivity Cable CA-126

Instruction Manual HI Refractometer for Refractive Index and Brix Measurements

Esterification Method 1 Method to 2800 mg/l (as acetic acid) Reagent Solution

Instruction manual EAR SET 1 EAR SET 4

PART 1 - INTRODUCTION...

Instruction Manual HI Portable Waterproof Microprocessor Dissolved Oxygen Meter

MOISTURE (Karl Fischer, Buffered)

Experiment 17: Potentiometric Titration

FerroVer Method 1 Method to 3.0, 1.0 to 30.0 and 10.0 to mg/l Fe Powder Pillows

JUMO tecline HD ph and JUMO tecline HD Rd

Recommended Procedures for Use of YSI Water Quality Monitoring Instruments during Oil Spills

MODEL 970 DISSOLVED OXYGEN METER OPERATING MANUAL

Portable digital microprocessor thermometers with interchangeable probes

Extraction: Separation of Acidic Substances

Calibration of Glassware

Microwave Meter. Instruction Manual

DETERMINATION OF PHOSPHORIC ACID CONTENT IN SOFT DRINKS

General Purpose ph/orp Sensor

Care, Maintenance, and Storage of YSI 6-Series Probes and Sondes

Chemistry 119: Experiment 7. Potentiometric Titration of Ascorbic Acid in Vitamin C Tablets

Instruction Manual Temp 4/5/6 Temperature Meter Series

804 Ti Stand. Manual EN

Dimethylglyoxime Method Method to 6.0 mg/l Ni TNTplus 856

MIST DECORATIVE LAMP WITH ESSENTIAL OIL DIFFUSER

DISSOLVED OXYGEN METER Model : DO-5509

CataLoG No. weight o.d. i.d. GLaSSwaRe

Handbook. Thermo Scientific. ph Electrode Selection Handbook

9. Analysis of an Acid-Base Titration Curve: The Gran Plot

Appendix C. Vernier Tutorial

CONDUCTIVITY SENSOR. Description D0382. Figure 1. The Conductivity Sensor

Transcription:

SenTix 950 SenTix 980 ph combination electrodes with refillable liquid reference system Operating manual ba75843e01 08/2009

SenTix The latest version of the present operating manual can be found on the Internet under www.wtw.com. Copyright Weilheim 2009, WTW GmbH Reprinting - even as excerpts - is only allowed with the explicit written authorization of WTW GmbH, Weilheim. Printed in Germany. 12 ba75843e01 08/2009

SenTix General information General information Automatic sensor recognition The sensor electronics with the stored sensor data is in the connecting head of the electrode. The data include, among other things, the sensor type and series number. With each calibration, the calibration data is written in the sensor and the calibration history is recorded. The data is recalled by the meter when the sensor is connected and is used for measurement and for measured value documentation. Storing the calibration data in the sensor ensures that the correct slope and asymmetry are automatically used if the sensor is operated with several meters. The digital transmission technique guarantees the failure-free communication with the meter even with long connection cables. If the sensor firmware is enhanced by WTW, it can be updated via the meter. ba75843e01 08/2009 13

Technical data SenTix Technical data General data WTW model Reference electrolyte Junction NTC Special features SenTix 950 KCl 3 mol/l, Ag + free Ceramic Yes Plastic shaft SenTix 980 KCl 3 mol/l, Ag + free Platinum Yes Measurement and application characteristics WTW model ph measuring range Allowed temperature range SenTix 950 0.000... 14.000 0... 80 C (32... 176 F) SenTix 980 0.000... 14.000 0... 100 C (32... 212 F) WTW model Membrane resistance Typical application at 25 C SenTix 950 < 1 GOhm Field SenTix 980 < 600 MOhm Laboratory Shaft dimensions, shaft material, electrical connection WTW model Shaft Electrical connection Length [mm] Ø [mm] Material Electrode connection Meter connection Cable length SenTix 950 120 12 Polyamide Fixed cable Digital plug 1.5 m SenTix 980 120 12 Glass Fixed cable Digital plug 1.5 m Connection cable Diameter 4.3 mm Smallest allowed bend radius Fixed installation: 20 mm Flexible use: 60 mm Plug type Socket, 4 pins Accuracy of the IDS measuring technique Measured parameter Accuracy (± 1 digit) ph ± 0.004 U [mv] ± 0.2 T [ C] ± 0.1 14 ba75843e01 08/2009

SenTix Commissioning, measuring, calibration Commissioning, measuring, calibration Commissioning The electrode is filled with reference electrolyte solution in the factory. Prepare the electrode for measuring as follows: Open the refilling opening for the reference electrolyte solution. Depending on the model, the stopper of the refilling opening is an elastomer stopper or a slider. The refilling opening must always be open during calibration and measurement! Refilling opening Refilling opening Remove the watering cap from the electrode tip. Possible salt deposits in the area of the watering cap do not affect the measuring characteristics and can easily be removed with deionized water. Please keep the watering cap. It is required for the electrode to be stored. Always keep the watering cap clean. SenTix 950: Remove any gas bubbles behind the ph membrane by shaking. Connect the electrode to the meter. Calibrate the electrode according to the operating manual of the meter and observe the following rules while doing so: Calibration and measurement: General rules Make sure the refilling opening for the reference electrolyte solution is open. Avoid the carryover of any solution (sample or buffer solution) from one measurement to the next by taking the following measures: Shortly rinse the calibration and sample beakers with the solution the beakers are to be filled with next. Between measurements, rinse the electrode with the solution that follows. Alternatively, you can also rinse the electrode with deionized water and then carefully dab it dry. Immerse the electrode in the solution in a vertical or slightly tilted position. Make sure the immersion depth is correct. The junction must be completely submersed in the solution. The junction is in the area of the bottom end of the shaft (see figure). At the same time, the level of the reference elec- ba75843e01 08/2009 15

Storage SenTix trolyte in the electrode must be at least 2 cm above the level of the solution. Shaft Reference electrolyte Junction (Example) Glass membrane Provide approximately the same stirring conditions for measuring as for calibrating. Prevent contact of the ph membrane to the beaker bottom to avoid scratches on the ph membrane. Subsequent calibrations The frequency of subsequent calibrations depends on the application. The meters provide an option where you can enter a calibration interval. After the calibration interval has expired, the meter will automatically remind you of the due calibration. Storage During short measuring breaks With the refilling opening open, immerse the electrode in reference electrolyte (KCl 3 mol/l, Ag + free). Prior to the next measurement, shortly rinse the electrode with the test sample or deionized water. Prevent contact of the ph membrane to the beaker bottom to avoid scratches on the ph membrane. Overnight or longer Put the clean electrode in the watering cap that is filled with reference electrolyte (KCl 3 mol/l, Ag + free) and close the refilling opening. ph electrodes must not be stored dry or in deionized water. The electrode could be permanently damaged by this. If the liquid in the watering cap has dried up, condition the electrode in reference electrolyte (KCl 3 mol/l, Ag+ + free) for at least 24 hours. 16 ba75843e01 08/2009

SenTix Aging During longer storing periods, salt sediments may develop on the watering cap. They do not affect the measuring characteristics and can easily be removed with deionized water when the electrode is put into operation again. Aging Every ph electrode undergoes a natural aging process. With aging, the responding behavior becomes slower and the electrode slope and asymmetry change. Moreover, extreme operating conditions can considerably shorten the lifetime of the electrode. These are: Strong acids or lyes, hydrofluoric acid, organic solvents, oils, fats, bromides, sulfides, iodides, proteins High temperatures High changes in ph and temperature. The warranty does not cover failure caused by measuring conditions and mechanical damage. Maintenance and cleaning Refilling the reference electrolyte During operation, a small amount of reference electrolyte leaks through the junction from the electrode into the test sample. If the level of reference electrolyte becomes too low with time, refill it through the refilling opening. Refilling is very easy with the enclosed dropping bottle. Proceed as follows: Cut off the tip of the dropping bottle at a right angle until the opening in the tip can be seen Open the refilling opening of the electrode Press the tip of the dropping bottle into the refilling opening while turning it slightly Pump the reference electrolyte in the shaft using the dropping bottle Pull the dropping bottle out of the refilling opening while turning it slightly as necessary. ba75843e01 08/2009 17

Maintenance and cleaning SenTix Cleaning Remove water-soluble contamination by rinsing with deionized water. Remove other contamination as follows: Contamination Cleaning procedure Fat and oil Rinse with water containing household washing-up liquid Lime and hydroxide deposits Rinse with citric acid (10 % by weight) Proteins Immerse in pepsin cleaning solution PEP/pH for approx. 1 hour. : Make sure the level of the reference electrolyte is above that of the cleaning solution. Hydrofluoric acid, hot phosphoric acid and strong alkaline solutions destroy the glass membrane. After cleaning Rinse the electrode with deionized water and condition it in reference electrolyte solution for at least 1 hour. Then recalibrate the electrode. 18 ba75843e01 08/2009

SenTix Wear parts and accessories Wear parts and accessories Description Model Order no. Reference electrolyte solution 250 ml KCl-250 109 705 (KCl 3 mol/l, Ag + free) Pepsin cleaning solution 3 x 250 ml PEP/pH 109 648 Detailed information on our wide range of buffer solutions and more accessories is given in the price list of the WTW catalog "Laboratory and field instrumentation". Disposal When the electrode is at the end of its operational lifetime, please dispose of it as electronic waste and not with unsorted municipal waste. It is illegal to dispose of it with the household refuse. ba75843e01 08/2009 19

Disposal SenTix 20 ba75843e01 08/2009