VWR SPECTROPHOTOMETERS



Similar documents
Agilent Cary 4000/5000/6000i Series UV-Vis-NIR

instruments Analytical Instruments for Science

Agilent Cary 60 UV-Vis

UV-VISIBLE SPECTROPHOTOMETER

73 Series Spectrophotometers

UV-Vis spectrophotometers

Thermo Scientific GENESYS 10S Series UV-Visible Spectrophotometers

Hitachi Double Beam Spectrophotometer

Fiber Optic Sampling by UV/Vis and UV/Vis/NIR Spectroscopy

MODELS 6400/6405 SPECTROPHOTOMETERS OPERATING MANUAL

UV-VIS Spectrophotometer

Shimadzu UV-VIS User s Guide

Hitachi U-4100 UV-vis-NIR spectrophotometer (341-F)

MCAL Spectrophotometry. Spectrophotometry

Fundamentals of modern UV-visible spectroscopy. Presentation Materials

EXPERIMENT 11 UV/VIS Spectroscopy and Spectrophotometry: Spectrophotometric Analysis of Potassium Permanganate Solutions.

INTERNATIONAL OLIVE COUNCIL

Cary 100 Bio UV-Vis Operating Instructions 09/25/2012 S.V.

Ultraviolet-Visible (UV-Vis) Spectroscopy Background Information

Spectrophotometer Water Quality Analysers

UV/VIS Spectrophotometer PG INSTRUMENTS LIMITED

Spectroscopy. Biogeochemical Methods OCN 633. Rebecca Briggs

Hitachi Spectrophotometer

UV-VIS-NIR Cary 4000, 5000, 6000i Spectrophotometers Preliminary Performance Data

JASCO. FP-6000 Series Spectrofluorometer. Fluorescence Spectrophotometer

NanoPhotometer. Microvolume and Cuvette Spectroscopy

Flame Direct Attach UV-VIS Integrated Sampling System Installation and Operation Instructions

Spectroquant Pharo. No limits. The new spectrophotometer system to meet your individual needs

Hellma. Where precision becomes an art. Calibration standards for spectrophotometers by Hellma

MCP 100 MCP 150. Modular Compact Polarimeters. ::: Superior Optical Instruments

We bring quality to light. MAS 40 Mini-Array Spectrometer. light measurement

UV-VIS VARIAN, INC. Cary 100/300 UV-Vis. S p e c t r o p h o t o m e t e r s

Copyright by Mark Brandt, Ph.D. 12

haze-gard i The objective standard for a clear view Global communication Reliable and Precise

Using the Spectrophotometer

DU 800 Spectrophotometer Installation and Operating Instructions

UV/VIS/IR SPECTROSCOPY ANALYSIS OF NANOPARTICLES

BY UV SPECTROPHOTOMETRY

Thermo Scientific NanoDrop Products. Revolutionary technology. Elegant simplicity. Instruments for microvolume analysis of biomolecules

CARY UV-VIS-NIR SPECTROPHOTOMETERS UV-VIS-NIR. Typical Specifications

Shimadzu UV-1700 UV/Vis Spectrometer Updated July 13, 2010

Measurement of Enhanced Specular Reflector (ESR) Films Using a LAMBDA 1050 UV/Vis/NIR Spectrometer and URA Accessory

Chem 131A: Absorbance of Riboflavin

A compact, lightweight, portable optical spectrum analyzer for DWDM system installation and maintenance.

TurbiDirect TurbiCheck TurbiCheck WL

Colorimetry Extinction coefficient (ε) Lambda max (λ max ) Qualitative vs. quantitative analysis

Chemistry 111 Lab: Intro to Spectrophotometry Page E-1

University of Wisconsin Chemistry 524 Spectroscopic Applications (GFAA, ICP, UV/Vis, Fluorescence)

C101-E087J UV-2450 UV Shimadzu UV-VIS Spectrophotometers

C125-E008H RF-5301PC. Shimadzu Spectrofluorophotometer

Spectrofluorophotometer

Test equipment for temperature and its reduction

EXPERIMENT 5. Molecular Absorption Spectroscopy: Determination of Iron With 1,10-Phenanthroline

Rhopoint Instruments Ltd.

USB-500 Series Low-Cost Data Loggers and Accessories

Operating manual. SpectralTransfer. - Backup of measurement data - Backup and recovery of user-defined methods - Software and methods update

Uses of Derivative Spectroscopy

HPLC Analysis of Acetaminophen Tablets with Waters Alliance and Agilent Supplies

SUPPLY & INSTALLATION OF UV-VIS SPECTROPHOTOMETER IN SCHOOL OF BASIC SCIENCE, IIT MANDI

USB-500/600 Series Low-Cost Data Loggers and Accessories

MODEL 6305 UV/VISIBLE RANGE SPECTROPHOTOMETER

Reaction of Blue Food Dye with Bleach

Reaction Stoichiometry and the Formation of a Metal Ion Complex

Measuring Protein Concentration through Absorption Spectrophotometry

USB-500 Series Stand-Alone, Low-Cost Data Loggers

USB-ISS-UV/VIS Integrated Sampling System Installation and Operation Instructions

User guide for Cary 5000 absorption spectrometer with external DRA 1800 attachment.

Absorbance Spectrophotometry: Analysis of FD&C Red Food Dye #40

UV-VIS-NIR. Varian Cary 4000, 5000 and 6000i Spectrophotometers

USB-500/600 Series Low-Cost Data Loggers and Accessories

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

Multi-Function Ground

Reflectance Measurements of Materials Used in the Solar Industry. Selecting the Appropriate Accessories for UV/Vis/NIR Measurements.

ICC Recommendations for Color Measurement

DMA-1 Direct Mercury Analyzer

Inspection and Illumination Systems for Visual Quality Assurance. Large selection Attractive prices Tailored solutions. optometron.

MB3600 Versatile FT-NIR analyzer designed for your industry The most reliable FT-NIR specifically designed for QA/QC

Kit Highlights and Key Features

UV-1700 series SERVICE MANUAL

Functional description. photolab 6100 VIS. Spectrophotometer. (identical to spectroflex 6100) ba75847e01 08/2009

Getting Started with UVProbe

1/4 Specifications Hidex 300 SL automatic TDCR liquid scintillation counter


Chem 405 Biochemistry Lab I Experiment 2 Quantitation of an unknown protein solution.

Radiant Dyes Laser Accessories GmbH

COLORIMETER. Description 0358BT. Figure 1. The Colorimeter

Problem Set 6 UV-Vis Absorption Spectroscopy Express the following absorbances in terms of percent transmittance:

Blackbody Radiation References INTRODUCTION

OPTICAL MEASURING MACHINES

1 Laboratory #5: Grating Spectrometer

Online Infrared Flue Gas Analyzer Gasboard 3000

Dual Laser InfraRed (IR) Thermometer

The best lab standard. 1,4 Megapixels 2/3 inch sensor Giant pixel size 6 times optical zoom Massive 16-bit imaging for enhanced dynamic

ADU 5. Automatic Distillation Unit

Curing Lights HALOGEN CURING LIGHTS 5.2 L.E.D. CURING LIGHTS 5.3 LIGHT GUIDES 5.5 RADIOMETERS 5.6 ACCESSORIES FOR CURING LIGHTS 5.

How To Use A Detector 2

Spectrophotometry and the Beer-Lambert Law: An Important Analytical Technique in Chemistry

Spectrofluorophotometer RF-6000 C125-E009

DMA-80 Direct Mercury Analyzer

Connect to a remote PC via Ethernet with a monitor, keyboard, and mouse. This network monitor offers both long distance and wireless transmission.

Transcription:

VWR SPECTROPHOTOMETERS Reliable Accurate Easy to Use New_Spectrophotometry_v2.indd 2 Your first choice for spectrophotometry 5/9/2014 2:22:18 PM

Quality Guaranteed VWR SPECTROPHOTOMETERS Single Beam Units VWR offers a choice of 5 models of single beam VIS and UV/VIS spectrophotometers, each with a ready-to-use package including glass or quartz cells. These robust units feature easy handling plus all the functions required for daily measurements in your lab. A large sample compartment coupled with an extensive range of optional accessories allow you to customize your unit to your requirements. Double Beam Option The newest member of the spectrophotmeter family is the UV- 6300PC. With our large range of accessories, this powerful unit is an all round top performer in a host of different applications, from research to pharmaceutical labs, QC to new material development. Software Two different software packages M.Wave Professional or UV-Analyst (depending on the model) transform these stand-alone units to allow greater results, storage and more demanding analysis of results. 2 VWR INTERNATIONAL 1.800.932.5000 vwr.com

Represents the reliability and robustness that we provide in all our units. M.Wave Professional Full functionality of stand-alone unit plus more powerful data processing, expanded data collecting and storage capability. Optional for V-1200, included with UV-1600PC. Basic functionalities Basic photometric mode Quantitative test (standard curve) Wavelength scanning Kinetics DNA/protein Multi-wavelength test System utility PC system requirements: Pentium or above PC, CD-ROM, USB ports; 32 MB memory (>256 MB is strongly recommended); >50 MB hard disc space; Microsoft Windows 2000/XP/Vista/7 PC Software UV-Analyst Full functionality of stand-alone unit plus more powerful data processing, expanded data collecting and storage capability. Included with UV-3000PC, UV-3100PC and UV-6300PC. Basic functionalities Basic photometric mode Quantitative test (standard curve) Wavelength scanning Kinetics DNA/protein Multiwavelength test System utility PC system requirements: Pentium or above PC, CD-ROM, USB ports; 32 MB memory (>256 MB is strongly recommended); >50 MB hard disc space; Microsoft Windows 2000/XP/Vista/7 More advanced software functionalities Printable spectrums, results and reports No memory limits by spectrophotometer Standard curve Up to 20 standards, curve fitting: Linear/linear through zero/ square Wavelength scan Automatic record of peaks and valleys (unlimited number of channels) Off-line calculation and processing including: 1st to 4th derivation Rescaling axes, smoothing, combination, zooming, overlap Multiwavelength scan Up to 20 wavelengths DNA/protein concentration More advanced software functionalities Printable spectrums, results and reports No memory limits by spectrophotometer Standard curve - up to 20 standards Wavelength scan Automatic record of peaks and valleys (unlimited number of channels) Off-line calculation and processing including: 1st to 4th derivation Smoothing, combination, zooming, overlap Multiwavelength scan Up to 20 wavelengths Multiple sample measurement (with optional automatic cell changer) vwr.com 1.800.932.5000 VWR INTERNATIONAL 3

Represents the reliability and robustness that we provide in all our units. VWR Spectrophotometers, Basic Vis or UV-VIS, V-1200, UV-1600PC Large LCD display (128 64 pixels) Can save up to total 200 results and 200 standard curves Download data to PC via USB interface Application software allows PC control of the spectrophotometers (delivered with UV-1600PC); includes the following methods: Basic mode, quantitative, wavelength scan, kinetics, multi-wavelength, DNA/protein Variety of optional accessories including an automatic 8-cell changer Description V-1200 Spectrophotometer UV-1600PC Scanning Spectrophotometer Cat. No. 10037-434 10037-436 Specifications Display Graphic LCD (128 64 pixels) Interfaces USB port to PC / parallel port to printer Languages EN, DE, ES, FR Light source Tungsten halogen Deuterium/tungsten halogen Model V-1200 UV-1600PC Optical system Single beam, grating 1200 lines/ mm silicon photodiode detector Photometric accuracy ±0.5% T Photometric range 0.3 to 3 A; 0-200% T Photometric reproducibility ±0.3% T Photometric stability ±0.002 A/h @ 500 nm Power requirements 120V Spectral bandwidth (nm) 4 Stray light 0.3% T ±0.05% T @ 220, 360 nm Wavelength accuracy (nm) ±2 ±0.5 Wavelength range (nm) 325-1000 190-1100 Wavelength repeatability (nm) 0.8 0.3 Weight (kg) 12 W D H (mm) 490 360 210 14 490 360 240 ±0.5% T ±0.2% T 4 VWR INTERNATIONAL 1.800.932.5000 vwr.com New_Spectrophotometry_v2.indd 4 5/9/2014 2:22:37 PM

Represents the reliability and robustness that we provide in all our units. VWR Spectrophotometers, UV-VIS Scanning, UV-3100PC and Vis V-3000-PC Large LCD display (320 240 pixels) Full scan mode Easily accessible USB port for data import and export Supplied application software UV-VIS Analyst allows PC control of the spectrophotometer Methods for PC control or stand-alone include: Basic mode, quantitative, wavelength scan, kinetics, multiwavelength, DNA/protein The range of accessories includes an automatic 8-cell changer and Peltier thermostatted single cell holder Description Cat. No. V-3000PC, VIS Scanning Spectrophotometer 10037-440 UV-3100PC, UV/VIS Scanning Spectrophotometer 10037-438 Specifications Baseline flatness ±0.002 A (200-1000 nm) ±0.002 A (320-1000 nm) Display Interfaces Languages 5 graphic LCD (320 240 pixels) USB port to PC / parallel port to printer EN, DE, ES, FR Light source Deuterium/tungsten halogen Tungsten halogen Model UV-3100PC UV-VIS V-3000PC No. of standards Optical system Photometric accuracy Photometric range Photometric reproducibility Photometric stability Power requirements 200 standard curves Single beam, grating 1200 lines/mm, silicon photodiode detector ±0.5% T or 0.005 A at 1 A 0.3 to 3 A; 0-200% T; 0-9999 Conc ±0.2% T ±0.002 A/h @ 500 nm 120V Results storage 200 Scan speed (nm/min) Low, medium, high (max. 3000 nm/min) Spectral bandwidth (nm) 2 4 Stray light ±0.05% T @ 220, 360 nm ±0.05% T at 360 nm Wavelength accuracy (nm) ±0.5 Wavelength range (nm) 190-1100 320-1100 Wavelength repeatability (nm) 0.2 Weight (kg) 14 12 W D H (mm) 490 360 240 vwr.com 1.800.932.5000 VWR INTERNATIONAL 5

VWR Double Beam UV-VIS Spectrophotometer Standard photometrics - absorption, transmission, concentration Quantitative analysis and kinetics Multi-wavelength scan, spectrum scan DNA/RNA and protein analysis Description Cat. No. UV-6300PC Spectrophotometer 10037-442 Specifications Baseline flatness Control Display Interfaces Keyboard Languages Light source Model Optical system PC software Photometric accuracy Photometric range Photometric stability Scan 0.001 A (200-1000 nm) Internal control via keypad with optional PC control LCD 320 240 pixel USB and parallel printer interface Keypad English, French, German and Spanish Deuterium and tungsten lamps UV-6300PC Double beam UV-Vis Analyst ±0.002 A at 1 A; 0.3% T 0.3 to 3.0 A; 0 to 200% T; 0-9999C 0.001 A/h at 500 nm Scan speed (nm/min) 100-3000 Spectral bandwidth (nm) 1 Storage capacity Stray light Wavelength accuracy (nm) ±0.3 Wavelength range (nm) 190-1100 Weight (kg) 26 Scan intervals: 0.1; 0.2; 0.5; 1.0 and 5.0 nm 200 results and 200 standard curves 0.05% T at 220 and 360 nm W D H (mm) 590 420 260 Accessories for the V-1200, UV-1600PC and the UV-3100PC Description Cat. No. Cell Holders for SPECTRO-16/18 Series, Spectrophotometer 4-Cell, For Up To 100Mm Square Cuvette 10037-448 For Cylindrical Cell 10037-450 Water-Jacketed Single Cell 10037-452 8-Position Auto Cell Changer 10037-456 Solid Sample Holder, Single Cell 10037-458 10mm Water-Jacketed 4-Cell Holder 10037-460 A-102 Peltier Constant-Temperature System, Beam Height:15mm 10037-540 Ambient Sipper Unit, A-101 Sipper System, Beam Height:15mm 10037-542 A-100 Constant-Temperature Sipper System, Beam Height:15mm 10037-544 Replacement Lamps Halogen Lamp, 12V 20W, Philips, For V-1200, UV-1600Pc, UV-3100Pc,V-3000Pc 10037-484 Halogen Lamp, 12V 20W, Osram, For UV-6300Pc 10037-498 Deuterium Lamp, Milas for UV-1600Pc, UV-3100Pc 10037-486 6 VWR INTERNATIONAL 1.800.932.5000 vwr.com

VWR Spectrosil Spectrophotometer Cells Far UV quartz Wavelength range of 170 2700 nm Matched sets available Fully heat-fused construction Description External Dimensions Internal Dimensions Cover Type Pathlength Sample Volume Cat. No. Standard 10W x 10L x 52H mm 10W x 10L mm Screw Cap with 10 mm 3.5 ml 414004-054 Rectangular Gasket Standard 10W x 10L x 52H mm 10W x 10L mm Screw Cap with 10 mm 3.5 ml 414004-055 Rectangular Septum Micro, Black 12.5W x 12.5L x 45H mm 2W x 10L mm Flat Lid 10 mm 0.7 ml 414004-070 Sides Semi-Micro 12.5W x 12.5L x 45H mm 4W x 10L mm Flat Lid 10 mm 1.4 ml 414004-068 Standard Rectangular 12.5W x 12.5L x 48H mm 10W x 10L mm Stopper 10 mm 3.5 ml 414004-078 VWR Spectrosil Fluorometer Cells Far UV quartz Wavelength range of 170 2700 nm Fully heat-fused construction Exterior Dimensions Cover Type Cat. No. 12.5W x 12.5L x 45H mm Stopper 414004-056 12.5W x 12.5L x 45H mm Flat Lid 414004-064 VWR Two-Sided Disposable Plastic Cuvettes Compatible with most spectrophotometers and photometers, these two-sided disposable cuvettes are ideal for most spectrophotometry applications in the visible and near-uv range. Cuvettes are constructed of high-quality polymethyl methacrylate (PMMA or acrylic ) or polystyrene (PS), and provide accurate, reliable results. Available in macro and semi-macro sizes to accommodate most sample volumes. Acrylic cuvettes are suitable for assays between 300nm and 900nm. Polystyrene cuvettes are ideal for routine assays between 340nm and 900nm. Cuvettes have a 10mm lightpath and include an arrow mark to indicate direction of transmission and reduce variation. They are grouped by manufacturing mold cavity number to ensure the lowest variation in extinction coefficient, and are packaged in low-dust, low-scratch material. Description Material Volume Range Cat. No. Semi-Micro Acrylic (PMMA) 1.5 3.0 ml 97000-590 Semi-Micro Polystyrene (PS) 1.5 3.0 ml 97000-586 Macro Acrylic (PMMA) 2.5 4.5 ml 97000-588 Macro Polystyrene (PS) 2.5 4.5 ml 97000-584 VWR Standard Spectrophotometer Cuvettes Feature four optical windows that are recessed to prevent scratching. Description Volume L x W x H Pathlength Visibility Cat. No. Standard Cuvette, PS Grade 4.5 ml 10 x 10 x 45 mm 10 mm 340-800 nm 58017-880 Polystyrene Standard Cuvette, UV Grade 4.5 ml 10 x 10 x 45 mm 10 mm 280-800 nm 58017-875 Polymethylmethacrylate Cap for 4.5 ml Cuvettes with Square Opening, Polypropylene 89000-628 vwr.com 1.800.932.5000 VWR INTERNATIONAL 7

0514 2.5 M Lit.No. 93332