Spectrofluorophotometer
|
|
|
- Aron Horn
- 9 years ago
- Views:
Transcription
1 Spectrofluorophotometer RF-5301PC C125-E008J
2 World s Highest Level Performance and Windows Software Open Up a New Spectrum of Fluorescence Analysis. High-Sensitivity (SN Ratio Over 150) Sensitivity is the essence of fluorescence analysis. The high-throughput optical system in the RF-5301PC employs a blazed holographic grating, photomultiplier and digital circuit to provide the highest level SN ratio attainable. High-Speed Scanning High-speed scanning up to 5,500 nm/min allows you to measure a spectrum in seconds. In addition, a monochromator slewing speed of about 20,000 nm/min enables quick and easy setting of two or more wavelengths. Versatile Sample Compartment Size The sample compartment measures 140 mm wide, 170 mm deep and 140 mm high, enabling the use of micro cells, high-sensitivity cells, LC flow cells, etc. for a wide range of applications. Built-In Performance Checks When the instrument is switched ON, operating conditions of the spectrophotometer are automatically verified. In addition, built-in noise level (SN ratio) and light source (Xenon lamp) usage features help maintain the instrument in its optimum condition, providing absolute confidence in the quality of the data.
3 Windows-Based Workstation A PC directly controls the instrument for data acquisition and processing. The Windows friendly operating environment allows you to perform measurement, data processing, editing and recording in one continuous operation with a click of the mouse. The Copy Graph function allows easy transfer of measurement data or spectra to word processing or spreadsheet software for preparation of documents or additional calculations. From Routine Analysis to Research Employing the Highest Level of Sensitivity in the World! Features of Fluorescence Spectrometry Tens to thousands of times higher sensitivity than absorption spectrometry High selectivity (combining excitation and fluorescence wavelengths allows measuring even mixtures) Life Sciences Amino acids, peptides, proteins, fats, sugars, vitamins, coenzymes, amines, etc. Qualitative/quantitative analysis Enzyme reaction research Research of reaction mechanisms through analysis of substrates, coenzymes, and proteins (tryptophan and tyrosine residue) Antigen-antibody reactions Research of protein-protein, protein-nucleic acid, and protein-sugar interactions Analysis of intracellular ions (such as Ca 2+ ) using a fluorescence probe (such as Fura-2) Analysis of neurotransmitters (such as catecholamines) Research of nucleic acid hybridization Research of biomembranes Food Products Amino acids, proteins, fats, carbohydrates, vitamins, coenzymes, antibiotics, food additives (such as flavorings, seasonings, and antioxidants), cooking oil (such as vegetable oils and animal oils), and pesticides (carbamate, organophosphorus, and 1-naphthylacetic acid) Food ingredient analysis and quantitative analysis Inspections for residual pesticides Chemicals / Environment Organic, inorganic, and polymer compounds (such as fibers, plastics, and rubbers) Spectrofluorophotometer RF-5301PC Trace analysis Materials science research Photochemical reaction research Polymer research Optical materials research Assessment of atmospheric, water, and soil pollution such as the analysis of polycyclic aromatic hydrocarbon compounds Crude oil and coal analysis
4 Windows-Based Software Provides Powerful Support for Sample Analysis and Data Processing Windows-Based Control 3 Measurement Modes SpeedBox TM Select from 3 measurement modes Copy and Paste Wide Selection of Data Processing Functions Enables comprehensive management, from measurements to data analysis and report creation/output. Online help is provided as well. According to the Sample Spectrum Measurement Mode To measure spectra, simply click the [Start] button. Displays up to 10 spectra in the same window and performs calculations interactively. Freely zoom in or out using the mouse. Shimadzu's proprietary radar function allows viewing all spectra with a single click. Quantitative Measurement Mode Automatically creates calibration curves from measurement of standard samples. To quantitate unknown samples, simply click the [Read] button. PopUpScan allows confirming spectra while quantitative measurements are still in progress. Quantitation method: Peak height Calibration curves: 1st to 3rd order equations Mean value calculation function Time Course Measurement Mode High sensitivity, a stable baseline, and a 20-bit high-resolution A/D converter ensure reliable detection of small changes in samples. The activity value calculation function supports even enzyme research. 4
5 One-Click Operation SpeedBox Create buttons for frequently used functions to execute the functions with a single click. Freely customize button shapes, locations, and other features. Compatible with Commercial Software Applications Copy & Paste Data can be copied and pasted to Windows-based applications, such as word processing and spreadsheet software, which allows creating sophisticated reports. The ASCII conversion function allows transferring data to spreadsheet software. Simple and Powerful Extensive Data Processing Functions Use these data processing functions to correct data, extract hidden information, and so on, from the spectra obtained. Four basic arithmetic operations Smoothing Area calculation Differentiation Peak detection Activity value calculation Operate all functions easily and visually using the mouse. RF-5301PC Spectrofluorophotometer 5
6 Fast and Smart Monochromator and High Expandability Provide Powerful Support for Measurement and Analysis SN Ratio over 150:1* Max. Scan Speed of 5,500 nm/min Wavelength Slewing Speed of 20,000 nm/min Search Function Self-Diagnostic Function High sensitivity and high speed scanning provide quick and easy measurements. The search and self-diagnostic functions allow performing measurements without time-consuming processes. * Signal-to-noise ratio is from a Raman peak for distilled water with an excitation wavelength of 350 nm and bandwidth of 5 nm. High Sensitivity SN Ratio over 150:1 A bright optical system featuring a blazed holographic grating and digital signal processing enable ultra-trace analysis at signal-to-noise ratios over 150:1. Note: SN ratio is measured for the Raman line of distilled water Excitation wavelength Bandwidth 0-98 % response 350 nm 5 nm 2.0 sec Detects Optimal Excitation and Fluorescence Wavelengths Search Function Simply click the [Search] button. Automatically detects optimal excitation and fluorescence wavelengths. Automatically determines fluorescence from Rayleigh scattering, Raman scattering, 2nd-order light, etc. Makes time-consuming wavelength settings easy. Note: For a bandwidth of 10 nm, the SN ratio is equivalent to over 600:1. Enables High-Speed Measurements Max. Scan Speed of 5,500 nm/min An advanced direct wavelength drive mechanism provides spectra with minimal distortion, even at high speeds. A maximum scan speed of 5,500 nm/min enables high-speed spectra monitoring. Fast 20,000 nm/min wavelength slewing speed improves measurement efficiency. Automatic Instrument Performance Management Self-Diagnostic Function Automatically checks the operating status of the drive system when power is switched ON. Excitation slit Excitation monochromator Fluorescence slit Fluorescence monochromator Zero setting The software automatically performs time-consuming instrument management and performance checks, making it possible to use the instrument in an optimal state at all times. Manages lamp usage hours. Automatically measures and calculates SN ratios. 6
7 Large Sample Compartment High Degree of Expandability Easy to Use, Large Size Large Sample Compartment Tailor systems to samples and measurement methods. Allows Configuring a Variety of Systems High Degree of Expandability A large sample compartment provides plenty of space, improving ease of use. A wide variety of optional equipment can be attached. Various types of cell holders Various types of flow cell units Polarizer attachment Outputs analog signals of fluorescence intensity. Can be connected to a Chromatopac integrator Enables chromatographic measurements Note: Analog signals are output at a full scale of 1 V. Systems can be configured to samples and measurement methods. Specifications Hardware Software Light source Excitation and emission monochromators Wavelength scale Measuring wavelength range Spectral bandwidth 150 W Xenon lamp. Ozone resolving type lamp housing Blazed holographic grating F2.5, 1300 grooves/mm nm and 0 order nm and 0 order as standard nm and 0 order with the optional R928 photomultiplier 6-step selection of 1.5, 3, 5, 10, 15 and 20 nm. (6 nm bandwidth is available for half sample height on the excitation side only.) Measurement Data processing Filing Excitation, emission and synchronous spectrum measurement, time-course measurement, quantitation, automatic search of optimal excitation and emission wavelengths, PopUp Scan. Arithmetic calculation between spectrum and a constant, smoothing, 1st through 4th derivatives, 1/Y, logarithmic conversion, data printout (with or without activity value computation), peak pick, point pick, area calculation, averaging (in quantitation), generation of calibration curves of 1st through 3rd order Save, recall, and delete of data. Conversion into ASCll and DIF formats. Wavelength accuracy Light source compensation Sensitivity ±1.5 nm Dynode feedback system with monochromatic light monitoring The SN ratio is 150 or higher for the Raman line of distilled water (350 nm excitation wavelength, 5 nm spectral bandwidth, and 2-second response for 98% of the full scale). Data output Maintenance Automatic scale adjustment, readout of data at user-specified point, data printout (preview function provided), selection of colors and types of curves Automatic monitoring of signal-to-noise ratio, monitoring of the run time of light source lamp Wavelength scanning Wavelength slewing speed Response 7-step selection of Survey (about 5500 nm/min), Super (about 3000 nm/min), Very Fast, Fast, Medium, Slow and Very Slow About 20,000 nm/min. 8-step selection of 0.02, 0.03, 0.1, 0.25, 0.5, 2, 4 and 8 seconds for 98% of the full scale User interface Other functions PC requirements SpeedBox (assign icons for commonly used menu commands) Data exchange via clipboard, auto response control, automatic shutter CPU: 1GHz or higher OS : Windows 7 Professional, Windows XP Professional (SP2/SP3), Windows Vista Business (SP1) 32 bit Sensitivity selection 2 steps of HIGH and LOW (The sensitivity at HIGH is about 50 times that of LOW.) Interface RS-223C interface, interface for autosampler, and interface for sipper unit. Dimensions and weight W667 D530 H270 mm; 43 kg. Power requirements 100, 120, 220, 240 V; 50/60 Hz; 400 VA. Operational temperature range C Operational humidity range 40-80% (Below 70% with temperature higher than 30 C). RF-5301PC Spectrofluorophotometer 7
8 Wide Variety of Optional Accessories Provides Powerful Support for Measurement and Analysis Intracellular Calcium Measurement System This measurement system uses a fluorescence probe to measure real-time changes in concentrations of Ca 2+, H +, and other intracellular messengers. Measures up to 4 wavelengths, allowing measurements using multiple fluorescence probes. High-speed switching between wavelengths enables switching from 340 nm to 380 nm in a minimum 0.5 seconds, using a Fura-2 probe. Displays real-time changes in fluorescence intensity (maximum of 4) and ratios (maximum of 4) during measurements. Support for quantitation using single-wavelength quantitation, two-wavelength quantitation, and calibration curves enables measurement using Fluo-3, Fura-2, BCECF, and other fluorescence probes. Compatible with Window 7 Professional / XP Professional (SP2 / SP3) and Vista Business (SP1). System Contents P/N RF-5301PC Spectrofluorophotometer Intracellular Ca 2+ Measurement Software (Super Ion Probe) Constant-Temperature Cell Holder with Stirrer Constant-Temperature Water Circulator Syringe Adapter Computer and printer P/N
9 Options NTT-2200P Constant- Temperature Water Circulator P/N Constant-Temperature Single Cell Holder with Stirrer P/N (100V) P/N (120V) P/N (220/240V) High Sensitivity Cell Holder P/N Circulates temperature-controlled water to a constant-temperature cell holder. -Temperature range: Ambient + 5 C to + 80 C -Temperature control precision: 0.05 C~ -Max. pumping rate: 27/31 L/min, 9.5/13 m (50/60 Hz) -External circulation nozzle: 10.5 mm OD (both outlet and return) -Tank capacity: About 10 L (9 L during use) -Safety features: Detection of over-temperature of Upper or Lower limits, Detection of heater wire malfunction, Protection of heating too little circulating water, Detection of sensor malfunction, Independent overheat protection, Over current circuit protector -Standard accessories: Lid with handles, Rubber hose (4 m, 9 mm ID), Hose clamps (4 pc.), Instruction manual -Dimensions: W270 H560 D400 (mm) -Power requirements: 100 VAC, 1250 VA, with 1.7 m power cord and grounded plug Note: Piping to Constant-Temperature Cell Holder (P/N xx) is possible by the hose (9 mm ID). Keeps the sample at the desired constant temperature during measurement by circulating temperature-controlled water (5-70 C) around the sample cell. The stirring option has variable speed control and the minimum sample volume is 2 ml. Effective for fluorometry of suspended cell samples. Note: Does not include the Temperature Controlled Water Bath. Not applicable to samples having a specific gravity greatly different from that of the solvent. Note: The hose joint is applied to the 6-9 mm ID tube. Constant-Temperature Four Cell Holder P/N Keeps four sample cells at the desired constant temperature via connection to a water bath. Note: Requires the Temperature Controlled Water Bath. This cell holder enhances the sensitivity two to three times or more. This is recommended for low concentrations. It repeatedly reflects the excitation and emission beams through the sample to increase the excitation efficiency. Solid (Powder) Sample Holder P/N Provides a means to examine the fluorescence of a solid sample. The angle of the holder is designed to limit the reflected excitation beam from the emission monochromator. Standard accessories include a sample holder, quartz plate, powder sample plate, spacers and a sample fixing bar. Cutoff filters are included to reduce scattering (U-340, IHU-310, L-42, Y-50, O-56, R-60). Rectangular Flow Cell, 120µL P/N Used for fluorescence monitoring of effluents in column chromatography. Made of fused silica. Requires adapter (P/N ). RF-5301PC Spectrofluorophotometer 9
10 Options Polarizer Attachment (for UV/Vis region) P/N Polarizer Attachment (for Vis region) P/N Quartz Cell Polished on Four Sides P/N Non-Fluorescent Cell P/N Flow Cell Unit (120L) for LC Application P/N Measurement of fluorescence polarization provides information on the size, fluidity and environments of fluorescent molecules. Permits reliable measurement of polarization characteristics over a wide wavelength range from 240 nm to 800 nm. Micro Cell Holder with Micro Cell P/N Provides a 10 mm square non-fluorescent cell, polished on four sides. This cell is recommended for trace analysis, particularly when using low UV wavelengths for excitation. Does not fluoresce when excitation wavelengths from 240 to 260 nm are used. Flow-Thru Cell Unit for HPLC (12L) P/N The square micro-flow cell has an inner volume of 120 µl and is made of silica to ensure minimum light scattering. The inlet and outlet tubes are both made of vinyl resin and are 0.5 mm I.D. and 2 mm O.D. R Photomultiplier P/N Permits measurement of samples as small as 400 µl in volume. The cell is installed in an adapter of the same dimensions as an ordinary 10 mm square cell, so it can be placed in the standard cell holder. With this attachment, the RF-5301PC is used as a highly sensitive spectral fluorescence monitor in HPLC. Free selection of the excitation and emission wavelengths permits selective detection. The mobile phase stream can be stopped for spectral measurement, so that chromatographic peaks can be qualitatively determined with higher reliability. The flow-thru cell is a square type with an inner volume as small as 12 µl and is made of silica, ensuring minimized light scattering. Extends the measuring wavelength range from 750 to 900 nm. Filter Set P/N Includes 8 filters: two broad-band interference filters U-340 and B-390 for isolation of excitation wavelengths of and nm, respectively. Six cutoff filters: UV-29, L-41, Y-46, Y-50, O-56 and R-60 with approximately 50%T at 300, 420, 460, 500, 560 and 600 nm, respectively. 10
11 8mm dia. Test Tube Holder P/N Bottom Rise Sample Stage P/N Sipper Unit 5300 P/N Holds a test tube, 8 mm outer diameter and 45 mm-100 mm long. The minimum sample volume required is 400 µl. Raises the sample cell position in order to reduce the minimum sample volume to 1.5 ml. Aspirates solution samples using a peristaltic pump driven by a stepping motor, to be measured successively. Minimum sample volume is 2 ml. Linked operation with the ASC-5 Auto Sampler possible. 12mm dia. Test Tube Holder P/N Spectra Correction Accessory P/N Used to correct excitation and emission spectra in the wavelength region from 250 nm to 600 nm, using rhodamine solution as the reference (quantum counter). ASC-5 Auto Sample Changer P/N xx Holds a test tube, 12 mm outer diameter and 60 mm-100 mm long. Builds an automatic multi sample spectrophotometry system in combination with a sipper unit. Up to 100 test tubes are set together on the rack. The aspirating nozzle is programmable to move X, Y and Z (vertical) direction. RF-5301PC Spectrofluorophotometer 11
12 RF-5301PC Company names, product/service names and logos used in this publication are trademarks and trade names of Shimadzu Corporation or its affiliates, whether or not they are used with trademark symbol TM or. Third-party trademarks and trade names may be used in this publication to refer to either the entities or their products/services. Shimadzu disclaims any proprietary interest in trademarks and trade names other than its own. For Research Use Only. Not for use in diagnostic procedures. The contents of this publication are provided to you as is without warranty of any kind, and are subject to change without notice. Shimadzu does not assume any responsibility or liability for any damage, whether direct or indirect, relating to the use of this publication. Shimadzu Corporation, 2013 Printed in Japan AIT
C125-E008H RF-5301PC. Shimadzu Spectrofluorophotometer
C125-E008H RF-5301PC Shimadzu Spectrofluorophotometer World s Highest Level Performance and Windows TM Software From Routine Analysis to Research Employing the Highest Level of Sensitivity in the World!
Spectrofluorophotometer RF-6000 C125-E009
Spectrofluorophotometer RF-6000 C125-E009 Striving for the Ultimate in Accuracy and Easy Operability By combining new technologies with those cultivated over Shimadzu's long history, the Shimadzu spectrofluorophotometer
UV-VIS Spectrophotometer
UV-VIS Spectrophotometer C101-E130 UV-VIS Spectrophotometer Easy to Operate Easy-to-see LCD and buttons ensure simple measurement and instrument validation operations. A Wealth of Measurement Modes From
Hitachi Double Beam Spectrophotometer
Hitachi Double Beam Spectrophotometer Spectrophotometer simpler to use and higher in dependability thanks to mounting of a large-size color LCD. High resolution satisfying European Pharmacopoeia (spectral
JASCO. FP-6000 Series Spectrofluorometer. Fluorescence Spectrophotometer
JASCO Fluorescence Spectrophotometer FP-6000 Series Spectrofluorometer The FP-6000 Series meets the demands of both research and routine analysis by combining a highly sensitive and flexible optical system.
Agilent Cary 60 UV-Vis
Agilent Cary 60 UV-Vis Efficient. Accurate. Flexible. Specifications Introduction The Agilent Cary 60 UV-Vis spectrophotometer is efficient, accurate and flexible, and is designed to meet both current
UV-Vis spectrophotometers
UV-Vis spectrophotometers an Advanced Digital Technology EXPERIENCE SECOMAM is proud to provide the new fourthgeneration UVIKON ultraviolet-visible spectrophotometers.with more than five decades of experience
UVC LEDs for. Environmental Monitoring
UVC LEDs for Environmental Monitoring Environmental monitoring relies extensively on molecular spectroscopy for tracking air quality, water and wastewater quality, and detecting hazardous substances. Advances
VWR SPECTROPHOTOMETERS
VWR SPECTROPHOTOMETERS Reliable Accurate Easy to Use New_Spectrophotometry_v2.indd 2 Your first choice for spectrophotometry 5/9/2014 2:22:18 PM Quality Guaranteed VWR SPECTROPHOTOMETERS Single Beam Units
Shimadzu UV-VIS User s Guide
Shimadzu UV-VIS User s Guide 1) Push the F4 button on the UV-VIS instrument keypad. This will enable PC control. Push the F4 Button 2) Log into the UV-VIS software with your username and password. 3) After
Cary 100 Bio UV-Vis Operating Instructions 09/25/2012 S.V.
1234 Hach Hall 515-294-5805 www.cif.iastate.edu Cary 100 Bio UV-Vis Operating Instructions 09/25/2012 S.V. Location: Contact: 1240 Hach Hall Steve Veysey, 1234 Hach Hall Safety All researchers working
DENSITY MEASURING SYSTEMS
SHIBAYAMA SCIENTIFIC CO., LTD. DENSITY MEASURING SYSTEMS Density Gradient Tube Method Direct Reading Type A / Type B Comply with the standards below: JIS K-0061-1992, K-7112 1980 ASTM D1505 Type A /Left
Agilent Cary 4000/5000/6000i Series UV-Vis-NIR
Agilent Cary 4000/5000/6000i Series UV-Vis-NIR Guaranteed specifications Design overview Double beam, ratio recording, double out-of-plane Littrow monochromator UV-Vis-NIR spectrophotometer (Agilent Cary
Fiber Optic Sampling by UV/Vis and UV/Vis/NIR Spectroscopy
Fiber Optic Sampling by UV/Vis and UV/Vis/NIR Spectroscopy UV/VIS AND UV/VIS/NIR SPECTROSCOPY A P P L I C A T I O N N O T E Introduction The availability and applications of fiber optic sampling in UV/Vis
Amino Acid Analyzer L-8900
Amino Acid Analyzer L-8900 VWR - Hitachi Your Partner in Amino Acid Analysis Hitachi has manufactured more than 1800 Amino Acid Analysers for over 40 years. The new Amino Acid Analyser Model L-8900 is
Appendix 5 Overview of requirements in English
Appendix 5 Overview of requirements in English This document is a translation of Appendix 4 (Bilag 4) section 2. This translation is meant as a service for the bidder and in case of any differences between
Copyright 1999 2010 by Mark Brandt, Ph.D. 12
Introduction to Absorbance Spectroscopy A single beam spectrophotometer is comprised of a light source, a monochromator, a sample holder, and a detector. An ideal instrument has a light source that emits
Multifunctional Autosampler AOC-6000 C146-E272A
Multifunctional Autosampler C146-E272A Multifunctional Autosampler Multifunctional Autosampler Dramatically Improves GC/MS Analysis Productivity Automatic Switching Between Three GC/MS Sample Injection
Fundamentals of modern UV-visible spectroscopy. Presentation Materials
Fundamentals of modern UV-visible spectroscopy Presentation Materials The Electromagnetic Spectrum E = hν ν = c / λ 1 Electronic Transitions in Formaldehyde 2 Electronic Transitions and Spectra of Atoms
Hitachi Spectrophotometer
Hitachi Spectrophotometer Spectrophotometer Meeting a Wide Range of Analytical Needs from Liquid to Solid Sample Measurements Single monochromator U-3900 Stray light : 0.015% or less Photometric range
instruments Analytical Instruments for Science
instruments Analytical Instruments for Science instruments Contents PAGE NO. Introduction 4 T60 UV-Vis Spectrophotometer 6 T70 UV-Vis Spectrophotometer 10 T80 UV-Vis Spectrophotometer 14 T90+ UV-Vis Spectrophotometer
Quick Start Guide Chromeleon 7.2
Chromeleon 7.2 7229.0004 Revision 1.0 July 2013 Table of Contents 1 Introduction... 1 1.1 About this Document... 1 1.2 Other Documentation... 2 2 Using Chromeleon... 3 2.1 Overview... 3 2.2 Starting Chromeleon...
MCAL Spectrophotometry. Spectrophotometry
MCAL Spectrophotometry Instruments include: Cary 50 UV-vis Spectrophotometer Eclipse Spectrofluorometer HPLC Diode Array and Fluorescence ICP-OES with CCD detection Spectrophotometry The instruments all
University of Wisconsin Chemistry 524 Spectroscopic Applications (GFAA, ICP, UV/Vis, Fluorescence)
University of Wisconsin Chemistry 524 Spectroscopic Applications (GFAA, ICP, UV/Vis, Fluorescence) For this laboratory exercise, you will explore a variety of spectroscopic methods used in an analytical
73 Series Spectrophotometers
73 Series Spectrophotometers The 73 series introduces four new spectrophotometers to the extensive Jenway range. These spectrophotometers use icon driven software and have an improved navigation system
Overview. Triple quadrupole (MS/MS) systems provide in comparison to single quadrupole (MS) systems: Introduction
Advantages of Using Triple Quadrupole over Single Quadrupole Mass Spectrometry to Quantify and Identify the Presence of Pesticides in Water and Soil Samples André Schreiber AB SCIEX Concord, Ontario (Canada)
UV-VIS VARIAN, INC. Cary 100/300 UV-Vis. S p e c t r o p h o t o m e t e r s
UV-VIS VARIAN, INC. Cary 100/300 UV-Vis S p e c t r o p h o t o m e t e r s Unmatched quality and performance Outstanding performance, flexibility, and ease of use are what you can expect from Varian s
FRACTION COLLECTOR. Microcomputer Controlled CHF122SC
FRACTION COLLECTOR Microcomputer Controlled CHF122SC From open column to HPLC liquid chromatography and general liquid samplings, the Super Fraction Collector, model CHF122SC has a wide range of uses.
Spectroscopy. Biogeochemical Methods OCN 633. Rebecca Briggs
Spectroscopy Biogeochemical Methods OCN 633 Rebecca Briggs Definitions of Spectrometry Defined by the method used to prepare the sample 1. Optical spectrometry Elements are converted to gaseous atoms or
AMD Analysis & Technology AG
AMD Analysis & Technology AG Application Note 120419 Author: Karl-Heinz Maurer APCI-MS Trace Analysis of volatile organic compounds in ambient air A) Introduction Trace analysis of volatile organic compounds
Determining the Quantity of Iron in a Vitamin Tablet. Evaluation copy
Determining the Quantity of Iron in a Vitamin Tablet Computer 34 As biochemical research becomes more sophisticated, we are learning more about the role of metallic elements in the human body. For example,
Products - Microarray Scanners - SpotLight Two-Color Microarray Fluorescence Scanners New! SpotLight 2 now available!
Products - Microarray Scanners - SpotLight Two-Color Microarray Fluorescence Scanners New! SpotLight 2 now available! Arrayit SpotLight Two-Color Microarray Scanners provide the market s most affordable
Shimadzu Simulated Distillation Gas Chromatograph System C184-E030
Shimadzu Simulated Distillation Gas Chromatograph System C184-E030 Meets All Simulated Distillation Gas Chromatograph Standards - Provides Highly Accurate Analysis Results with Excellent Reproducibility-
Measurement of Enhanced Specular Reflector (ESR) Films Using a LAMBDA 1050 UV/Vis/NIR Spectrometer and URA Accessory
FIELD APPLICATION REPORT UV/Vis/NIR Spectroscopy Author: Frank Padera Shelton, CT Contributor: Chris Lynch Shelton, CT Measurement of Enhanced Specular Reflector (ESR) Films Using a LAMBDA 1050 UV/Vis/NIR
We bring quality to light. MAS 40 Mini-Array Spectrometer. light measurement
MAS 40 Mini-Array Spectrometer light measurement Features at a glance Cost-effective and robust CCD spectrometer technology Standard USB interface Compatible with all Instrument Systems measuring adapters
Ultraviolet-Visible (UV-Vis) Spectroscopy Background Information
1 Ultraviolet-Visible (UV-Vis) Spectroscopy Background Information Instructions for the Operation of the Cary 300 Bio UV-Visible Spectrophotometer See the Thermo OMNIC Help reference on page 49. Ultraviolet-Visible
DAS202Tools v1.0.0 for DAS202 Operating Manual
DAS202Tools v1.0.0 for DAS202 Operating Manual DAT102Tools 1.0.0 Manual Table of context 2 Table of Contents 1 General Information... 3 2 PC... Configuration Requirements 3 3 Software Installation... 3
Manual Analysis Software AFD 1201
AFD 1200 - AcoustiTube Manual Analysis Software AFD 1201 Measurement of Transmission loss acc. to Song and Bolton 1 Table of Contents Introduction - Analysis Software AFD 1201... 3 AFD 1200 - AcoustiTube
Type-D EEG System for Regular EEG Clinic
Type-D EEG System for Regular EEG Clinic Type-D EEG amplifier Specifications 1. For Type-D Amplifier Input channels: 12/24/36/48 Monopolar EEG + 12channels Bipolar EEG+12 channels PSG. Power supply: Internal
Fiber Optic Distributed Temperature Sensor (B-DTS)
Fiber Optic Distributed Temperature Sensor (B-DTS) Low-cost Brillouin BOTDA scattering version For more information about our strain and temperature sensor system and related products, please visit www.ozoptics.com
C101-E087J UV-2450 UV-2550. Shimadzu UV-VIS Spectrophotometers
C101-E087J UV-2450 UV-2550 Shimadzu UV-VIS Spectrophotometers Ultra low stray light in the world's best double monochromator instrument UV-2550 High performance single monochromator instrument UV-2450
Introduction. Methods. Sample Processing
PO-CON1656 High-sensitivity, high-throughput quantitation of catecholamines and metanephrine in plasma by automated WCX-SP coupled to LC/MS/MS for clinical research ASMS 2016 MP-080 Ichiro HIRANO 1, Atsuhiko
MCP 100 MCP 150. Modular Compact Polarimeters. ::: Superior Optical Instruments
MCP 100 MCP 150 Modular Compact Polarimeters ::: Superior Optical Instruments Your Promise Anton Paar's Solution You have always made sure that your optically active substances meet all quality standards.
Mitos P-Pump. product datasheet
product datasheet page Product description 2 Main benefits 3 Why choose the Mitos P-Pump? 3 Closed-loop flow control 4 Product specifications 5 Accessories - overview 6 Mitos P-Pump Basic 7 Mitos P-Pump
Split Controller. User Manual SM-SS-F 2009/01/04
Split Controller SM-SS-F User Manual 2009/01/04 Table of contents 1. Parts illustration.... 1 2. Electrical technical data...... 2 3. Electrical connection...3 4. Assemble parts...4 4.1 Assemble the fixed
Gas Custody Transfer Calibration
Gas Custody Transfer Calibration Using multi variable temperature / pressure calibrators for flowmeter calibration 2013 Introduction Gas custody transfer flow computers require special calibration to perform
AMINO ACID ANALYSIS By High Performance Capillary Electrophoresis
AMINO ACID ANALYSIS By High Performance Capillary Electrophoresis Analysis of Amino Acid Standards Label free analysis using the HPCE-512 ABSTRACT Capillary electrophoresis using indirect UV detection
UV-VISIBLE SPECTROPHOTOMETER
instruments UV-VISIBLE SPECTROPHOTOMETER PRODUCT BROCHURE Analytical Instruments for Science Contents PAGE NO. Introduction 4 T60 UV-Vis Spectrophotometer 6 T70 UV-Vis Spectrophotometer 10 T80 UV-Vis Spectrophotometer
A compact, lightweight, portable optical spectrum analyzer for DWDM system installation and maintenance.
A compact, lightweight, portable optical spectrum analyzer for DWDM system installation and maintenance. Bulletin -01E http://www.yokogawa.com/tm/... Visit our website to sign for e-mail updates Compact,
Image Area EXCEPTIONAL PERFORMANCE FOR CHALLENGING MERCURY ANALYSES. FIMS 100 and 400. Flow Injection Mercury Systems
Image Area EXCEPTIONAL PERFORMANCE FOR CHALLENGING MERCURY ANALYSES FIMS 100 and 400 Flow Injection Mercury Systems Delivering the Performance You Need The determination and monitoring of sub-ppb concentrations
Experiment #5: Qualitative Absorption Spectroscopy
Experiment #5: Qualitative Absorption Spectroscopy One of the most important areas in the field of analytical chemistry is that of spectroscopy. In general terms, spectroscopy deals with the interactions
ATOMIC ABSORTION SPECTROSCOPY: rev. 4/2011 ANALYSIS OF COPPER IN FOOD AND VITAMINS
1 ATOMIC ABSORTION SPECTROSCOPY: rev. 4/2011 ANALYSIS OF COPPER IN FOOD AND VITAMINS Buck Scientific Atomic Absorption Spectrophotometer, Model 200 Atomic absorption spectroscopy (AAS) has for many years
IFC. A new perspective i l ifi ti. p p g p. Single softw FractPAL software plug-in for Agilent ChemStation. Medicinal Chemistry.
IFC A new perspective i l ifi ti Medicinal Chemistry p p CombiChem Compound Isolation Autopurification Drug Discovery y y q p p p p g p Single softw FractPAL software plug-in for Agilent ChemStation The
SPECTROSCOPY. Light interacting with matter as an analytical tool
SPECTROSCOPY Light interacting with matter as an analytical tool Electronic Excitation by UV/Vis Spectroscopy : X-ray: core electron excitation UV: valance electronic excitation IR: molecular vibrations
How To Read A Pipe From A Sensor
Liquid Level Sensor Installation on pipes. Sensing by means electrostatic capacity and is not influenced by the color of the pipe or liquid. Available in 8 to mm dia. and to mm dia. models to enable sensing
Online Infrared Flue Gas Analyzer Gasboard 3000
Online Infrared Flue Gas Analyzer Gasboard 3000 O 2 CO CO2 SO 2 NO NO x Use of measurement methods Proprietary Infrared NDIR Detectors - Micro-flow in ppm range: CO, NO, SO2, CO2 - Dual beam in % volume
BB-18 Black Body High Vacuum System Technical Description
BB-18 Black Body High Vacuum System Technical Description The BB-18 Black Body is versatile and is programmed for use as a fixed cold target at 80 K or variable target, at 80 K- 350 K no extra cost. The
2 Spectrophotometry and the Analysis of Riboflavin
2 Spectrophotometry and the Analysis of Riboflavin Objectives: A) To become familiar with operating the Platereader; B) to learn how to use the Platereader in determining the absorption spectrum of a compound
G4 ICARUS HF. Innovation with Integrity. Simultaneous Determination of Carbon and Sulfur in Solids. Combustion Method
G4 ICARUS HF Simultaneous Determination of Carbon and Sulfur in Solids Innovation with Integrity Combustion Method High Performance Carbon & Sulfur Analyzer Combustion Method with High-Frequency Furnace
THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES
TSI and TSI logo are registered trademarks of TSI Incorporated. SmartTune is a trademark of TSI Incorporated. THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES IFA 300 Constant Temperature Anemometry
ZEISS Axiocam 506 color Your Microscope Camera for Imaging of Large Sample Areas Fast, in True Color, and High Resolution
Product Information Version 1.0 ZEISS Axiocam 506 color Your Microscope Camera for Imaging of Large Sample Areas Fast, in True Color, and High Resolution ZEISS Axiocam 506 color Sensor Model Sensor Pixel
Beckman Coulter DTX 880 Multimode Detector Bergen County Technical Schools Stem Cell Lab
Beckman Coulter DTX 880 Multimode Detector Bergen County Technical Schools Stem Cell Lab Room 213 Beckman Coulter DTX 880 Multimode Detector Information The Beckman Coulter DTX 880 Multimode Detector is
The Measurement of Sensitivity in Fluorescence Spectroscopy
The Measurement of Sensitivity in Fluorescence Spectroscopy Among instrumental techniques, fluorescence spectroscopy is recognized as one of the more sensitive. In fluorescence, the intensity of the emission
GC-xt. The most flexible GC /GC-MS liquid sample injector
GC-xt Prep and Load Platform The most flexible GC /GC-MS liquid sample injector Environmental Foods/Beverages Consumer Products Forensics Petrochemicals/Polymers Pharmaceuticals GC-xt Liquid mode Prep
POLYDIMETHYLSILOXANE
POLYDIMETHYLSILOXANE Prepared at the 37th JECFA (1990), published in FNP 52 (1992) superseding specifications prepared at the 29th JECFA (1985), published in FNP 34 (1986). Metals and arsenic specifications
Computer Controlled Vortex Tube Refrigerator Unit, with SCADA TPVC
Technical Teaching Equipment Computer Controlled Vortex Tube Refrigerator Unit, with SCADA TPVC Teaching Technique used EDIBON SCADA System 2 Control Interface Box 5 Cables and Accessories 6 Manuals 3
Tuning & Mass Calibration
Tuning & Mass Calibration 1 1 The Sample List Sample List Name Project Name 2 The sample list is the top level screen in the TurboMass Gold Software. Data storage is set up in PROJECT files and within
Using the Spectrophotometer
Using the Spectrophotometer Introduction In this exercise, you will learn the basic principals of spectrophotometry and and serial dilution and their practical application. You will need these skills to
MultiQuant Software 2.0 for Targeted Protein / Peptide Quantification
MultiQuant Software 2.0 for Targeted Protein / Peptide Quantification Gold Standard for Quantitative Data Processing Because of the sensitivity, selectivity, speed and throughput at which MRM assays can
globe reactions made easy Process perfection
globe reactions made easy Process perfection Benefits More reactions in less time: The Globe oil drain unit and quick clamp allow single hand vessel changes in seconds Space saving: 50ml, 100ml, 250ml,
PDA Software Getting Started Guide
PDA Software Getting Started Guide 34 Maple Street Milford, MA 01757 WAT053020TP, Revision 1 NOTICE The information in this document is subject to change without notice and should not be construed as a
Dual Laser InfraRed (IR) Thermometer
User s Manual Dual Laser InfraRed (IR) Thermometer MODEL 42511 Introduction Congratulations on your purchase of the Model 42511 IR Thermometer. This Infrared thermometer measures and displays non-contact
API 3200 LC/MS/MS SYSTEM. Performance, productivity and value combined
API 3200 LC/MS/MS SYSTEM Performance, productivity and value combined API 3200 LC/MS/MS SYSTEM Reliability, reproducibility, and confidence in your data. With an unmatched heritage of technological innovation
EXPERIMENT 11 UV/VIS Spectroscopy and Spectrophotometry: Spectrophotometric Analysis of Potassium Permanganate Solutions.
EXPERIMENT 11 UV/VIS Spectroscopy and Spectrophotometry: Spectrophotometric Analysis of Potassium Permanganate Solutions. Outcomes After completing this experiment, the student should be able to: 1. Prepare
Title: Standard Operating Procedure for Thermo-Miran SapphIRe portable gas analyzer
Procedure No: SOP-039 Revision No: 1.1 January 21, 2011 Page No.: 1 of 11 1. INTRODUCTION AND SCOPE This document will outline specifics with regards to portable sampling analysis utilizing and operating
Installation Qualification SWIFT II and SWIFT 1000, version 2.03
Installation Qualification SWIFT II and SWIFT 1000, version 2.03 Introduction and requirements This software operates in the Windows 95, 98, 2000 and NT environments and comprises a number application
Technical Note. Roche Applied Science. No. LC 19/2004. Color Compensation
Roche Applied Science Technical Note No. LC 19/2004 Purpose of this Note Color The LightCycler System is able to simultaneously detect and analyze more than one color in each capillary. Due to overlap
Micromass LCT User s Guide
Micromass LCT User s Guide 1) Log on to MassLynx with your username & password. 2) After you have logged in, the MassLynx software will automatically run. 3) After MassLynx has come up, open your project
Thermo Scientific Dionex UltiMate 3000 Variable Wavelength Detectors
Chromatography Thermo Scientific Dionex UltiMate 3000 Variable Wavelength Detectors Product Specifications Integrating hardware, software and separation chemistry, we offer UHPLC to everyone for all needs
Overview. Introduction. AB SCIEX MPX -2 High Throughput TripleTOF 4600 LC/MS/MS System
Investigating the use of the AB SCIEX TripleTOF 4600 LC/MS/MS System for High Throughput Screening of Synthetic Cannabinoids/Metabolites in Human Urine AB SCIEX MPX -2 High Throughput TripleTOF 4600 LC/MS/MS
Related concepts Kohlrausch s law, equivalent conductivity, temperature dependence of conductivity, Ostwald s dilution law.
Conductivity of strong and weak electrolytes TEC Related concepts Kohlrausch s law, equivalent conductivity, temperature dependence of conductivity, Ostwald s dilution law. Principle It is possible to
SpecLine Offline Spectroscopy Analysis Software SPECLINE-P/SPECLINE-U. Installation and Operation Manual Document Number 000-20000-090-02-1209
SpecLine Offline Spectroscopy Analysis Software SPECLINE-P/SPECLINE-U Installation and Operation Manual Document Number 000-20000-090-02-1209 Offices: Ocean Optics, Inc. World Headquarters 830 Douglas
LightCycler 480 Real-Time PCR System
Roche Applied Science LightCycler 480 Real-Time PCR System Planned introduction of the LightCycler 480 System: September 2005 Rapid by nature, accurate by design The LightCycler 480 Real-Time PCR System
Trace Gas Exchange Measurements with Standard Infrared Analyzers
Practical Environmental Measurement Methods Trace Gas Exchange Measurements with Standard Infrared Analyzers Last change of document: February 23, 2007 Supervisor: Charles Robert Room no: S 4381 ph: 4352
Ultraviolet Spectroscopy
Ultraviolet Spectroscopy The wavelength of UV and visible light are substantially shorter than the wavelength of infrared radiation. The UV spectrum ranges from 100 to 400 nm. A UV-Vis spectrophotometer
The best lab standard. 1,4 Megapixels 2/3 inch sensor Giant pixel size 6 times optical zoom Massive 16-bit imaging for enhanced dynamic
1 AGENDA Product roadmap...3 Computer based system: PLATINUM..5 XPLORER.6 ESSENTIAL..7 Specifications Computer based system..8 Configuration Computer based system... 9 Software Computer based system...10
Measuring Protein Concentration through Absorption Spectrophotometry
Measuring Protein Concentration through Absorption Spectrophotometry In this lab exercise you will learn how to homogenize a tissue to extract the protein, and then how to use a protein assay reagent to
Chapter 28: High-Performance Liquid Chromatography (HPLC)
Chapter 28: High-Performance Liquid Chromatography (HPLC) Scope Instrumentation eluants, injectors, columns Modes of HPLC Partition chromatography Adsorption chromatography Ion chromatography Size exclusion
DMA-80 Direct Mercury Analyzer
DMA-80 Direct Mercury Analyzer Milestone Srl Milestone Srl 1 Introduction Mercury in the atmosphere can be from manmade sources (coal-fired power plants, municipal incinerators, industrial boilers) or
Waters Corporation. Waters 2690/5 USER & TROUBLESHOOTING GUIDE
Waters Corporation Waters 2690/5 USER & TROUBLESHOOTING GUIDE Contents 2690/5 Theory Setup procedures. Troubleshooting the 2690/5 User maintenance of the 2690/5 Spare Parts 2 2690/5 Theory 2690/5 Solvent
DUST EMISSION MONITORING SYSTEM
Applications Measurement of dust concentration in dry or moist, steamsaturated and corrosive stack gases Monitoring of municipal and hazardous waste and sewage sludge incinerators Monitoring of power plants
High Power Programmable DC Power Supplies PVS Series
Data Sheet High Power Programmable DC Power Supplies The PVS10005, PVS60085, and PVS60085MR programmable DC power supplies offer clean output power up to 5.1 kw, excellent regulation, and fast transient
NITRIC OXIDE and NITROGEN DIOXIDE 6014
NITRIC OXIDE and NITROGEN DIOXIDE 6014 NO MW: 30.01 CAS: 10102-43-9 RTECS: QX0525000 46.01 10102-44-0 QW9800000 METHOD: 6014, Issue 1 EVALUATION: FULL Issue 1: 15 August 1994 OSHA : 25 ppm NO; C 1 ppm
Dual Laser InfraRed (IR) Thermometer with Color Alert
User Manual Dual Laser InfraRed (IR) Thermometer with Color Alert MODEL 42509 Introduction Congratulations on your purchase of the Model 42509 IR Thermometer with Color Alert. This Infrared thermometer
haze-gard i The objective standard for a clear view Global communication Reliable and Precise
haze-gard i The objective standard for a clear view Transparent products can have a milky or fuzzy appearance dependent on its light scattering behaviour. The haze-gard i quantifies the visual perception
Zeiss 780 Training Notes
Zeiss 780 Training Notes 780 Start Up Sequence Do you need the argon laser, 458,488,514nm lines? No Turn on the Systems PC Switch Turn on Main Power Switch Yes Turn on the laser main power switch and turn
Lab 2 Biochemistry. Learning Objectives. Introduction. Lipid Structure and Role in Food. The lab has the following learning objectives.
1 Lab 2 Biochemistry Learning Objectives The lab has the following learning objectives. Investigate the role of double bonding in fatty acids, through models. Developing a calibration curve for a Benedict
GloMax Discover and Explorer. State-of-the-art multimode readers for luminescence, fluorescence and absorbance detection.
GloMax Discover and Explorer State-of-the-art multimode readers for luminescence, fluorescence and absorbance detection. Easy-To-Use The intuitive touchscreen display, preloaded protocols and automatic
Molecular Spectroscopy
Molecular Spectroscopy UV-Vis Spectroscopy Absorption Characteristics of Some Common Chromophores UV-Vis Spectroscopy Absorption Characteristics of Aromatic Compounds UV-Vis Spectroscopy Effect of extended
Fields of Application / Industry:
= Fields of Application / Industry: Chemistry / Polymer Industry Clinical Chemistry / Medicine / Hygiene / Health Care Cosmetics Electronics Energy Environment / Water / Waste Food / Agriculture Geology