SFG spectrometers. Sum Frequency Generation Vibrational Spectroscopy. More than 20 years experience



Similar documents
Raman Spectroscopy Basics

Radiant Dyes Laser Accessories GmbH

Raman spectroscopy Lecture

Nano-Spectroscopy. Solutions AFM-Raman, TERS, NSOM Chemical imaging at the nanoscale

Scanning Near-Field Optical Microscopy for Measuring Materials Properties at the Nanoscale

ULTRAFAST LASERS: Free electron lasers thrive from synergy with ultrafast laser systems

PUMPED Nd:YAG LASER. Last Revision: August 21, 2007

Status of the Free Electron Laser

Introduction to Fourier Transform Infrared Spectrometry

It has long been a goal to achieve higher spatial resolution in optical imaging and

Time out states and transitions

FTIR Instrumentation

5. Scanning Near-Field Optical Microscopy 5.1. Resolution of conventional optical microscopy

Experiment 5. Lasers and laser mode structure

Development of Optical Wave Microphone Measuring Sound Waves with No Diaphragm

Laboratory #3 Guide: Optical and Electrical Properties of Transparent Conductors -- September 23, 2014

Spectroscopy. Biogeochemical Methods OCN 633. Rebecca Briggs

Physics 441/2: Transmission Electron Microscope

Scanning Near Field Optical Microscopy: Principle, Instrumentation and Applications

DIODE PUMPED CRYSTALASER

Near-field scanning optical microscopy (SNOM)

Agilent Cary 4000/5000/6000i Series UV-Vis-NIR

Measurement of Enhanced Specular Reflector (ESR) Films Using a LAMBDA 1050 UV/Vis/NIR Spectrometer and URA Accessory

Synthetic Sensing: Proximity / Distance Sensors

MCAL Spectrophotometry. Spectrophotometry

Spectral Measurement Solutions for Industry and Research

RAY TRACING UNIFIED FIELD TRACING

Millijoules high master-slave pulse ratio 532 nm picosecond laser

Application Report: Running µshape TM on a VF-20 Interferometer

Lecture 20: Scanning Confocal Microscopy (SCM) Rationale for SCM. Principles and major components of SCM. Advantages and major applications of SCM.

Lab 9: The Acousto-Optic Effect

Experiment #5: Qualitative Absorption Spectroscopy

Pump-probe experiments with ultra-short temporal resolution

Fundamentals of modern UV-visible spectroscopy. Presentation Materials

Acousto-optic modulator

UV/VIS/IR SPECTROSCOPY ANALYSIS OF NANOPARTICLES

Infrared Spectroscopy: Theory

Agilent Cary 60 UV-Vis

Self-Guided Intense Laser Pulse Propagation in Air

Fibre Bragg Grating Sensors An Introduction to Bragg gratings and interrogation techniques

Efficiency, Dispersion and Straylight Performance Tests of Immersed Gratings for High Resolution Spectroscopy in the Near Infra-red

Single Mode Fiber Lasers

Advanced Research Raman System Raman Spectroscopy Systems

A Guide to Acousto-Optic Modulators

WAVELENGTH OF LIGHT - DIFFRACTION GRATING

A More Efficient Way to De-shelve 137 Ba +

Infrared Viewers. Manual

Interference. Physics 102 Workshop #3. General Instructions

MEMS mirror for low cost laser scanners. Ulrich Hofmann

Study of the Human Eye Working Principle: An impressive high angular resolution system with simple array detectors

Alignement of a ring cavity laser

Development and Commissioning of the Orion Laser Facility

SGS: Das Scanning Grating Spektrometer Ein kleines, günstiges Spektrometermodul auf Basis eines dispersiven Mikrosystems

The Fundamentals of Infrared Spectroscopy. Joe Van Gompel, PhD

Using light scattering method to find The surface tension of water

Problem Set 6 UV-Vis Absorption Spectroscopy Express the following absorbances in terms of percent transmittance:

Blackbody Radiation References INTRODUCTION

Raman Spectroscopy. 1. Introduction. 2. More on Raman Scattering. " scattered. " incident

Theremino System Theremino Spectrometer Technology

Infrared Spectroscopy 紅 外 線 光 譜 儀

Atomic Force Microscope

Zeiss 780 Training Notes

Polarization of Light

Modern Classical Optics

Realization of a UV fisheye hyperspectral camera

Module 13 : Measurements on Fiber Optic Systems

Nano Optics: Overview of Research Activities. Sergey I. Bozhevolnyi SENSE, University of Southern Denmark, Odense, DENMARK

Encoders for Linear Motors in the Electronics Industry

Basic principles and mechanisms of NSOM; Different scanning modes and systems of NSOM; General applications and advantages of NSOM.

product overview pco.edge family the most versatile scmos camera portfolio on the market pioneer in scmos image sensor technology

S2000 Spectrometer Data Sheet

SPATIAL-TIME PATTERN OF ELECTRICAL FIELD OF TERAHERTZ PULSE IN THE FAR FIELD

GRID AND PRISM SPECTROMETERS

Chapter 13 Confocal Laser Scanning Microscopy C. Robert Bagnell, Jr., Ph.D., 2012

- thus, the total number of atoms per second that absorb a photon is

Fig.1. The DAWN spacecraft

Optical Communications

Measuring Laser Power and Energy Output

E190Q Lecture 5 Autonomous Robot Navigation

Flame Direct Attach UV-VIS Integrated Sampling System Installation and Operation Instructions

Group Theory and Chemistry

Raman Scattering Theory David W. Hahn Department of Mechanical and Aerospace Engineering University of Florida

International Year of Light 2015 Tech-Talks BREGENZ: Mehmet Arik Well-Being in Office Applications Light Measurement & Quality Parameters

Helium-Neon Laser. Figure 1: Diagram of optical and electrical components used in the HeNe laser experiment.

Designing and Manufacturing Femtoseconds Ultra-broadband Lasers: Proven, Hands-free Reliability

ILLUSTRATIVE EXAMPLE: Given: A = 3 and B = 4 if we now want the value of C=? C = = = 25 or 2

UV-Vis spectrophotometers

Quasi-Continuous Wave (CW) UV Laser Xcyte Series

Back to Basics Fundamentals of Polymer Analysis

Using the Spectrophotometer

5.33 Lecture Notes: Introduction to Spectroscopy

LabRAM HR. Research Raman Made Easy! Raman Spectroscopy Systems. Spectroscopy Suite. Powered by:

Introduction to reflective aberration corrected holographic diffraction gratings

ENGINEERING METROLOGY

Non-Contact Vibration Measurement of Micro-Structures

Chapter 8. Low energy ion scattering study of Fe 4 N on Cu(100)

NEAR FIELD OPTICAL MICROSCOPY AND SPECTROSCOPY WITH STM AND AFM PROBES

P R E A M B L E. Facilitated workshop problems for class discussion (1.5 hours)

RL HW / RL HW+ / RL HGW / RL HV / RL HVPW/RL HVPW-G

instruments Analytical Instruments for Science

Transcription:

Sum Frequency Generation Vibrational Spectroscopy More than 20 years experience

Sum Frequency Generation Vibrational Spectroscopy Sum Frequency Generation Vibrational Spectroscopy (SFG-VS) is powerful and versatile method for in-situ investigation of surfaces and interfaces. In SFG-VS experiment a pulsed tunable infrared IR (ω IR) laser beam is mixed with a visible VIS (ω VIS) beam to produce an output at the sum frequency (ω SFG = ω IR + ω VIS). SFG is second order nonlinear process, which is allowed only in media without inversion symmetry. At surfaces or interfaces inversion symmetry is necessarily broken, that makes SFG highly surface specific. As the IR wavelength is scanned, active Spectra examples 0.4 vibrational modes of molecules at the interface give a resonant contribution to SF signal. The resonant enhancement provides spectral information on surface characteristic vibrational transitions. VIS 1.0 IR Z SFG X advantages Intrinsically surface specific Selective to adsorbed species Sensitive to submonolayer of molecules Applicable to all interfaces accessible to light Nondestructive Capable of high spectral and spatial resolution APPLICATIONS Investigation of surfaces and interfaces of solids, liquids, polymers, biological membranes and other systems Studies of surface structure, chemical composition and molecular orientation SFG signal, a.u. 0.3 0.2 0.1 SFG signal, a.u. 0.8 0.6 0.4 Remote sensing in hostile environment Investigation of surface reactions under real atmosphere, catalysis, surface dynamics 0 0.2 Studies of epitaxial growth, electrochemistry, material and environmental problems 1700 1710 1720 1730 1740 1750 1760 2800 3000 3200 3400 3600 3800 4000 Wavelength, cm -1 Wavelength, cm -1 SFG spectra of monoolein surface, 1 cm -1 scan step, 200 acquisitions per step. Water-air interface spectra, 200 acquisitions per step. Courtesy of University of Michigan

Design of the SFG Spectrometer Sum frequency generation (SFG) spectrometer is based on picosecond pump laser and optical parametric generator (OPG) with difference frequency generation (DFG) extension. Solid state mode-locked Nd:YAG laser featuring high pulse duration and energy stability is used in the system. Fundamental laser radiation splits into several channels in multichannel beams delivery unit. Two of these beams are used for pumping OPG and DFG. Small part of laser output beam, usually with doubled frequency (532 nm), is directed to VIS channel of SFG spectrometer. IR channel of spectrometer is pumped by DFG output beam. All system components are designed to operate in tandem. The sizes of individual compartments, positions of apertures and beams heights are fitted. As a result SFG spectrometer takes less space in laboratory. Standard versions usually fit on 1000 2400 mm optical table. No laser beams are passing across optical table. For example beam dedicated for VIS channel passes through OPG compartment only to minimize the risk of accident with dangerous high intensity laser radiation. It makes Ekspla spectrometer substantially safer comparing to home-made SFG-VS setups. Also optical parameters, like beam diameter, pulse energy, delays between channels are perfectly matched. We designed our spectrometer thinking about user friendly operation. Many components of the system are automated and controlled from PC. The opto-mechanical holders that need to be tuned often during routine operation are located around sample area and can be easily accessed without walking around the optical table. According to user needs different level of automation can be proposed, starting from most simple mechanical setup to most advanced fully motorized version. Detection system consists of monochromator with high stray light rejection and gated PMT based SF signal detector. The feature of such design is ability to perform measurements in room lighting. Second parallel detection channel is available as an option. All system components are controlled from single dedicated software. Program contains many useful instruments for automatic System Components Picosecond mode-locked Nd:YAG laser Multichannel beam delivery unit Picosecond optical parametric generator Spectroscopy module Monochromator PMT based signal detectors Data acquisition system Dedicated LabView software package for system control SFG spectra recording, dynamics monitoring, X-Y sample mapping, azimuthal scan and system parameters monitoring. Ekspla offers three common SFG spectrometer models for classical picosecond scanning SFG vibrational spectroscopy and several specialized models for most demanding users. Basic models are: SFG Classic, SFG Advanced and Double resonance SFG. They differ by IR beam tuning ranges and available VIS beam wavelengths (please see specifications page). Other models: Phase-sensitive SFG and SFG microscope provides unique features, which are described on next pages of this brochure. Signal detector SFG-Vx 440-515 nm (SFG) Monochromator Spectroscopy module PG501-DFGx 532/1064 nm (VIS) 2300-16000 nm (IR) PL2231 Optical parametric generator Picosecond laser 1064 nm 1064 nm 532/1064 nm (VIS) 532 nm Multichannel beams delivery unit SFGH500 Schematic layout of SFG Classic spectrometer.

SFG Spectrometer Modifications and Options Double resonance model Both IR and VIS wavelengths are tunable in Double resonance SFG spectrometer model. This twodimensional spectroscopy is more selective than single resonant SFG and applicable even to media with strong fluorescence. Double resonant SFG allows investigation of vibrational mode coupling to electron states at a surface. In Double resonance SFG spectrometer model second OPG is used to generate tunable VIS beam in UV and visible range. Modifications Double resonance SFG spectrometer allows investigation of vibrational mode coupling to electron states at a surface Phase sensitive SFG spectrometer allows measurement of the complex spectra of surface nonlinear response coefficients SFG microscope provides spectral and spatial surface information with micrometers resolution External view of Double resonance SFG spectrometer. SFG microscope SFG-VS spectroscopy combined with micrometers spatial resolution provides unique ability to investigate spatial and chemical variations across the surface as a function of time. An example of such application is chemical imaging of corrosion. SFG microscopy reveals presence of highly-coordinated complexes of molecules at particular stage of this process. SFG spectrometer offered by Ekspla uses far-field image formation technique. Illuminated area on the sample surface is substantially bigger than in regular SFG spectrometer. Using blazed grating and unique design optical system, image of surface plane is translated to matrix of ICCD camera. This way we can record distribution of SF signal at particular wavelength. For complete spectral and spatial information it is necessary to record multiple surface pictures at different wavelength. Integrated software package provides ability to visualize measured data making various cross sections: position-, wavelength- or time-dependent. Detection part of SFG microscope. OPTIONS Single or double wavelength VIS beam: 532 nm and/or 1064 nm One or two detection channels: main signal and reference Second harmonic generation surface spectroscopy option High resolution option down to 2 cm -1 Motorized VIS and IR beams alignment system

SFG signal from etched gold pattern. Image taken at ω IR = 3333 cm -1. Grid period 50 µm. An image of ODT covered etched gold sample. The lines are spaced, in order left-right 20, 5, 2, and 8 micrometers. Image taken at IR =2875 cm ¹ and acquired for 5000 laser shots. Courtesy of University of Houston SFG microscope provides spectral and spatial surface information with micrometers resolution.

Phase-sensitive SFG spectrometer In conventional SFG-VS intensity of SF signal is measured. It is proportional to the square of second order nonlinear susceptibility I SF ~ χ (2) 2. However, χ (2) is complex, and for complete information, we need to know both the amplitude and the phase. This will allow us to determine the absolute direction in which the bonds are pointing and characterize their tilt angle with respect to the surface. Measurement of the phase of an optical wave requires an interference scheme. Mixing the wave of interest with a reference wave of known phase generates an interference pattern, from which the phase of the wave can be deduced. In practice Phase-sensitive SFG experimental setup includes two samples generating SF signal simultaneously. One sample (usually called local oscillator) has well known and flat spectral response. Second one is investigated sample. The excitation beams are directed to first sample, where SFG beam is generated. Later all three beams are retranslated to the second sample, where another SFG beam is generated. Due to electromagnetic waves coherence both SFG beam are interfering. Setup contains the phase modular located on the SFG beam path between samples. We are able to change the phase of SFG beam by rotating it. This way we are recording two-dimensional interfererogram with wavelength and phase shift on x and y axis. Using fitting algorithms we are able to calculate the amplitude and phase of SF signal. Spectroscopy module of Phase-sensitive SFG spectrometer: internal view (left) and 3D drawing (right). Phase-sensitive SFG spectrometer software window showing interferograms of AZO (azophenylcarbazole) dyes on the Au surface and fitted SF spectra with amplitude and phase distinguished.

1064 nm 532 nm 355 nm Laser spectroscopy systems Main System Components Picosecond mode-locked Nd:YAG laser The heart of the spectrometer is solidstate picosecond laser. Its reliability is critical to perfect spectrometer operation and relevance of measured data. Two standard models of high energy lasers are dedicated for SFG spectrometers. Model PL2231 is fully diode pumped, which means that master oscillator and all following amplification stages are diode pumped. It features great long term parameters stability and minimal maintenance requirements. This model provides up to 40 mj per pulse output energy, which in most cases is enough for pumping OPG and VIS channel of SFG spectrometer. Model PL2251, which provides up to 100 mj per pulse output energy has similar internal structure to previously described PL2231, except power amplifier stage, which is flash lamp pumped in this case. This model usually is used for pumping of two independent OPG s. Such configuration is used in double resonance SFG version. It can be also considered in case, if SFG spectrometer must be optically synchronized with other experiment, e.g.: pump-probe and SFG simultaneous measurements. Multichannel beams delivery unit Fundamental laser radiation needs to be split into several channels and converted to different wavelenghts. Tunable IR radiation is generated in picosecond optical parametric generator (OPG). Large portion of laser output is converted into second or third harmonics and used for OPG pumping. Residual beam is spatially filtered, delayed and directed into SFG spectrometer as VIS channel. Usually it is converted into second harmonic (532 nm), but in some cases can be used also at fundamental wavelength (1064 nm) or tunable in visible range, when second OPG is used. Multichannel beams delivery unit SFGHX00 series provides all these features. Additionally it contains automatized VIS channel input energy monitoring and control. The VIS channel wavelength (if double wavelenght option is included) is changed manually. Setup also includes all needed separators and filters to block residual radiation and prevent it from reaching a sample. TO SFG SPECTROMETER AS VIS CHANNEL TO PG401 TO PG501 TO DFG FROM LASER 1064 nm Multichannel beam delivery unit 532 nm or/and 1064 nm SFGH1000 An example of Multichannel beams delivery unit used for Double resonance SFG spectrometer.

Picosecond optical parametric generator PG501 series picosecond optical parametric generator (OPG) feature high pulse energy and narrow linewidth. It is used for generation of tunable wavelength in broad spectral range. In SFG spectrometer it provides middle infrared radiation for IR channel. Optically this unit can be divided into several functional modules: traveling wave optical parametric generator (TWOPG); diffraction grating based linewidth narrowing system (LNS); optical parametric amplifier (OPA); difference frequency generator (DFG). The purpose of the TWOPG module is to generate parametric superfluorescence (PS). Spectral properties of the PS are determined by the properties of a nonlinear crystal and usually vary with the generated wavelength. In order to produce narrowband radiation, the output from OPG is narrowed by LNS down to 6 cm ¹ and then used to seed OPA. Output wavelength tuning is achieved by changing the angle of the nonlinear crystal(s) and grating. To ensure exceptional wavelength reproducibility, computerized control unit driven precise stepper motors rotate the nonlinear crystals and diffraction grating. Nonlinear crystal temperature stabilization ensures long term stability of the output radiation wavelength. In order to protect nonlinear crystals from damage, the pump pulse energy is monitored by built-in photodetectors, and the control unit produces an alert signal when pump pulse energy exceeds the preset value. DFG stage extends tuning range to mid IR, which corresponds to molecular vibrational fingerprints. Depending of OPG model, DFG output can cover spectral range 2.3 10 µm or 2.3 16 µm. All residual wavelengths are carefully filtered preventing residual radiation from reaching a sample. Visible laser pointer is installed inside each unit and aligned in-line with IR beam. It helps to manage invisible mid IR radiation and direct it through multiple optical elements into a sample. Some SFG-VS studies require better than 6 cm -1 spectral resolution. In such cases Ekspla offers unique design PG511 series OPG. In this system seed is generated in synchronously pumped optical parametric oscillator (SPOPO), which is temporally synchronized with laser regenerative amplifier. In this configuration radiation spectral width is narrowed down to 2 cm -1 in mid IR range. Pulse energy, µj 3-1 Wavenumber, 10 cm 5.00 3.33 2.50 2.00 1.66 1.43 1.25 1.11 1.00 350 300 250 200 150 100 DFG1P or DFG2 option 50 Air absorption DFG1 option 0 2000 3000 4000 5000 6000 7000 8000 9000 10000 Wavelength, nm Pulse energy, µj 120 100 80 60 40 20 0 Wavenumber, cm -1 1250.0 1000.0 833.3 714.2 625.0 8000 DFG2 10000 12000 14000 16000 Wavelength, nm Typical PG501-DFGx output energy curve in 2 300 10 000 nm and in 8 000 16 000 nm.

Spectroscopy module SFG spectroscopy module is designed with idea to make all adjustable components accessible within outspread hands. Most of them are located around sample area, when other components, which shouldn t be touched often, are hidden or located in more distant parts of the spectrometer. Some nodes, like IR polarization rotation system, which are rather difficult to align for unexperienced user, are motorized. Due to vertical beams plane geometry spectroscopy module is very convenient for practically all interfaces accessible by light. The size of spectroscopy module is adjusted to particular geometry of experiment and other options, which require some extra space. The most common experiment geometry is with co-propagating, non-collinear VIS and IR beams accessing the sample from top side. SFG beam is being caught reflected from the sample surface. The incidence angle of VIS and IR beams is around 55 60 deg., which guarantee best SFG efficiency. Such geometry is optimal for most samples, especially liquids and monolayers deposited on nontransparent substrates. VIS IR VIS IR LD VIS detector LD VIS detector HWP Periscope IR detector HWP Periscope IR detector Z-stage X-stage -rotation Principle optical schemes of SFG spectroscopy modules: top-bottom sample illumination geometry (top), tunable incidence angle geometry (bottom). Sample Tilt Y-stage Spacer Tilt Z-stage X-stage Y-stage -rotation Spacer SFG Sample SFG Large aperture parabolic mirror Glan prism Glan prism HWP Filter Notch filter To monochromator HWP Filter Notch filter To monochromator Useful utilities making spectrometer more user-friendly: motorized beam alignment and polarization control system (left) and camera with zooming objective for sample surface visualization (right).

However, in some experiments one layer of the sample can be transparent only for VIS beam, but not for IR beam and vice versa. In such case experimental setup requires different geometries. This problem can be solved, if we can access interface from different sides, for example directing VIS beam from the top and IR beam from the bottom. Ekspla offers several standard geometries: top side, bottom side, top-bottom side and total internal reflection. All of them can be implemented in single spectroscopy unit and easy interchangeable. The special design of SFG spectrometer provides possibility to change angles of interaction. This feature together with different polarization combinations helps better understand molecular dipoles orientation. In our spectrometer we use large aperture parabolic mirror. The sample is places in focal point of parabolic mirror. Such solution makes optical system extremely simple in operation, because it guarantee the same beams position on the sample surface and perfect overlap, when incidence angle is changed. Sample surface and beams overlap can be monitored using camera installed above sample area. This utility is integrated into every SFG spectrometer. On a special request sample visualization system can be combined with motorized beams adjustment. This allows to align SFG spectrometer from PC, even being physically far from it. It essentially solves safety issues and opens new possibilities for multiple long time experiments without accessing spectroscopy box. SFG Spectrometer Accessories Optional Accessories Six axis sample holder Sealed temperature controlled sample chamber Langmuir trough SFG spectrometer with Langmuir trough used for studies of the unique properties of molecules in monolayers. Compact and stable six axis manipulator for precise sample positioning. Hermetically sealed sample cell with heater, specially designed for SFG spectrometer, allows experiments under controlled environmental conditions. More detailed information about accessories for will be available soon. Please check Ekspla website: http://www.ekspla.com/product/sfg-spectrometer

Technical Specifications Version Classic Advanced Double resonance System (general) Spectral range 1000 4300 cm -1 625 4300 cm -1 1000 4300 cm -1 Spectral resolution < 6 cm -1 (optional: < 2 cm -1 ) < 10 cm -1 Spectra acquisition method Scanning Sample illumination geometry Top side, reflection (optional: bottom side, top-bottom side, total internal reflection) Incidence beams geometry Co-propagating, non-colinear (optional: colinear) Incidence angles Fixed, VIS ~60 deg, IR ~55 deg (optional: tunable) VIS beam wavelength 532 nm (optional: 1064 nm) Polarization (VIS, IR, SFG) Linear, selectable s or p, purity >1:100 Beam spot on the sample Selectable, ~150 600 µm Sensitivity Air-water spectra Tunable 420 680 nm (optional: 210 680 nm) Pump lasers Model PL2231 PL2251B Pulse energy 40 mj 80 mj (70 mj at 20 Hz) Pulse energy stability < 0.5 % < 0.8 % Pulse duration 28±3 ps 30±3 ps Pulse duration stability ±1.0 ps Pulse repetition rate 50 Hz 10 or 20 Hz Optical parametric generators IR source with standard linewidth (<6 cm -1 ) PG501-DFG1P PG501-DFG2 PG501-DFG1P IR source with narrow linewidth (<2 cm -1 ) PG511-DFG UV-VIS source for Double resonance SFG PG401 (optional: PG401-SH) For standard specifications please check the brochure of particular model Monochromators Model MS200 2xMS350 Type Czerny-Turner with single grating turret (optional: four grating turret) Focal length 200 mm 2 350 mm Slits 0 2.0 mm, manual Stray light rejection 10-5 10-10 Physical dimensions (footprint) Standard 2400 1000 mm 3600 1500 mm Extended (with special options or large accessories) 2700 1200 mm 3600 1500 mm

Why EKSPLA? Know-how in laser technology and nonlinear optics In house design and manufacturing Close partnership with scientific community Network of photonics companies in Vilnius Savanoriu Av. 237 LT-02300 Vilnius Lithuania Ph.: +370 5 264 96 29 Fax: +370 5 264 18 09 sales@ekspla.com www.ekspla.com Find local distributor at www.ekspla.com Revision number 150327