EXPANDED POLYSTYRENE (EPS) INSULATION BOARD SPECIFICATIONS



Similar documents
Dubai Municipality Standard DMS 1: Part 5: 2004

Guide Specification STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM

Fiberglas, Exterior Wall Thermal Insulation

Built to Last. Built for Beauty. Good. Solid. Logix. TM

SECTION PRE-ENGINEERED BUILDING BLANKET INSULATION

COMMERCIAL ITEM DESCRIPTION PACKAGING MATERIAL, SHEET

Product Guide Specification

Re-Cover Board-3. Insulation for Above the Deck ROOF WALL SPECIALTY

THIRD PARTY INSPECTION GUIDELINES FOR OWNERS AND GENERAL CONTRACTORS/CONSTRUCTION MANAGERS DS150

ENGINEERING SPECIFICATION PULTRUDED DYNAFORM FIBERGLASS STRUCTURAL SHAPES. July 1, 2008 Revision 2

THE DOW CHEMICAL COMPANY Issued: August 1, LARKIN CENTER 1605 JOSEPH DRIVE MIDLAND MICHIGAN (989)

09/07/07 GLASSFIBER REINFORCED CEMENT (GRC) C. S. I. Spec Master Spec Page 1

Colorado State University. Durrell Center Roof Repair

COMMERCIAL BUILDING APPLICATIONS

COMMERCIAL ITEM DESCRIPTION CUSHIONING MATERIAL, PACKAGING, CLOSED CELL FOAM PLANK

ENGINEERING SPECIFICATION FIBERGRATE MOLDED GRATING. January 24,

Backstop NT. Backstop NT Specifications DS180. A High Performance, Polymer-Based, Noncementitious Water-Resistive Membrane and Air Barrier

GigaCrete Specification PlasterMax

Specifications, Product Testing and Terminology

NAPCA BULLETIN APPLICATION PROCEDURES FOR CONCRETE WEIGHT COATING APPLIED BY THE COMPRESSION METHOD TO STEEL PIPE

Building Envelope Design by Roxul (BEDR ) FireWall and Roxul Plus MB. Fire Rated Board Insulation for Pre-Engineered Metal Buildings

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS REPORT HOLDER: FIRESTONE BUILDING PRODUCTS COMPANY, LLC

ROXUL Board Insulation Section Master Guide Specification (CAVITYROCK ) Page 1 April 2016

ENGINEERING SPECIFICATION PULTRUDED DYNARAIL FIBERGLASS LADDER & LADDER CAGES

How To Test For Premer Retardant

Building Envelope Design using ROXUL. FIREWALL and ROXUL PLUS MB. Fire Rated Board Insulation for Pre-Engineered Metal Buildings

Fire 2This Technical Bulletin has been commissioned by the UK SIP Association in

INSULATION FOR PRE-ENGINEERED METAL BUILDINGS. ROXUL SAFE 55 & 65 and ROXUL PLUS MB. Insulation for Pre-Engineered Metal Buildings

INSTRUCTIONS FOR COORDINATION SECTION SOLID SURFACE FABRICATIONS

Double Coated Urethane Foam Tapes

Standard Specification for Cellular Glass Thermal Insulation 1

LEGACY REPORT. (800) (562) A Subsidiary of the International Code Council. *Corrected March 2014

SPREFIX SPRAY INSULATION _ in the marine market.

Product Guide Specification

s ation lic app ntial Foamular sideor RE uide F Ily G am ation F sul In

2.18 INTERIOR & EXTERIOR FINISHES VAPOR & AIR BARRIERS

EcoTouch Insulation with PureFiber Technology

CHAPTER 7: Building Systems ROOFING SYSTEMS

IHSS-N1 WELDED HONEYCOMB CORE SPECIFICATION. Generated: Sergiy Papyshev Engineering. Approved: Don Prysi Manufacturing. Approved: Merzuk Ramic Quality

Requirements for Fire Protection of Light Weight Floor Systems **Act 1 Revisited**

Approval Standard for Plastic Suspended Ceiling Panels

VA25014B0516 VA CINCINNATI PROJECT NO INPATIENT BED TOWER ADDITION (4 TH AND 5 TH FLOORS) SECTION GYPSUM BOARD

SECTION PLAYGROUND SURFACING TILES

Roof Insulation Building. Energy. Environment friendly e-library

SECTION MODIFIED BITUMINOUS MEMBRANE ROOFING. A. Vapor barrier (base ply); cover board at existing roof deck.

SECTION GUARDA SECURITY WINDOW SCREENS

SECTION HVAC INSULATION. A. All work specified in this Section is subject to the provisions of Section

CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C Date of issue , Updated July 1, 2011

FLEX-WRAP Foam Pipe Wrap

INSTALLATION INSPECTION GUIDE FOR 3RD PARTY INSPECTORS FOR PAREX USA EXTERIOR INSULATION AND FINISH SYSTEMS

SPECIFICATION Section Insulated Precast Concrete Wall Panels

Third Party Inspection Guidelines For Inspectors As Part of the dryvitcare EIFS Repair/Restoration

3 Single-Coated Foam Tapes

RACQUETBALL, HANDBALL OR SQUASH COURTS AND GYMNASIUM WALL SURFACES

also in this issue Automatic Doors for the People Calculating Roof Insulation R-values Waterproofing and Concrete Balconies

FOAMULAR LT40, 400 and 600 insulations with minimum compressive strengths of

LEGACY REPORT. (800) (562) A Subsidiary of the International Code Council RETAINED ON U.S.

SFI SPECIFICATION 28.1 EFFECTIVE: SEPTEMBER 23, 2011 *

THERMAL INSULATION MATERIALS TEST METHOD SELECTION LIST

B. ASTM C 533 Calcium Silicate Block and Pipe Thermal Insulation. C. ASTM C 547 Mineral Fiber Preformed Insulation

Annex of the certificate (Page 1/6) Accreditation Scope

Underwriters Laboratories Testing Information

Know the Code: Using Spray Foam Insulation In Attics and Crawl Spaces

MASTERFORMAT SPECIFICATION

Class Number May FM Approvals LLC. All rights reserved.

SECTION METAL WALL PANELS

SECTION 1 GENERAL REQUIREMENTS

SECTION FIBERGLASS INSULATION

THERMAL BARRIERS FOR THE SPRAY POLYURETHANE FOAM INDUSTRY

NCMA TEK CONCRETE MASONRY FOUNDATION WALL DETAILS. TEK 5-3A Details (2003)

Tremco Fire Protection Systems Group Technical Bulletin

Gridstone Gypsum Ceiling Panels

SECTION ALUMINUM FRAMED ENTRANCES and STOREFRONTS. System 402 Flush-Glazed Screw Spline Storefront

1.02 DESCRIPTION A. This Section specifies furnishing and installing Cast in Place Detectable/Tactile Warning Surface tiles where indicated.

Sumitomo Electric Wiring Systems, Inc. Part Identification and Labeling Requirements

SECTION SANITARY SEWER AND STORM DRAIN SYSTEMS

ICC-ES Evaluation Report. ESR-3493 Reissued September 2014 This report is subject to renewal September 2015.

SECTION FLUID APPLIED ROOFING (LIGHT TRAFFIC DECKS OVER CONCRETE)

POLYURETHANE LINING AND COATING ON PIPE RAW WATER

Formwork Direct International Ltd Phone No +44 (0151) Fax no +44 (0151)

Understanding BS EN 771-3: Aggregate concrete masonry units

SPECIFICATION Aluminum Module Frames. Allowed anodization before fabrication for clear frames.

SECTION PRECAST CONCRETE STRUCTURES

09990 MOLD REMEDIATION, LEAD-BASED PAINT ABATEMENT AND ENCASEMENT OF ASBESTOS

The better way to build TM. Installation Manual. EXTERIOR WALL SIPs

Mold Preventing I nterior System

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: ICYNENE, INC.

CLEAR-DIVISIONS CENTERFOLD

CHESTERFLEX ROOF WATERPROOFING MEMBRANES

INTERNATIONAL ASSOCIATION OF CLASSIFICATION SOCIETIES. Interpretations of the FTP

Meeting the Fire Code with Continuous Foam Plastic Insulation

Aramid Fibre/Phenolic Honeycomb

ROXUL TOPROCK DD & MONOBOARD. Roofing Insulation for Commercial Construction. ROXUL TOPROCK DD and MONOBOARD

HexWeb CR III Corrosion Resistant Specification Grade Aluminum Honeycomb

Preformed Metal Roofing and Siding

European technical approval

A. The CONTRACTOR shall provide pipe coating, complete and in place, in accordance with the Contract Documents.

Division 9. SignaFlor Pad and Pour Flooring System

fire & soundproofing Insulation Roxul Safe n Sound Fire and Soundproofing Insulation for Interior Partition Walls and Floors

Transcription:

EXPANDED POLYSTYRENE (EPS) INSULATION BOARD SPECIFICATIONS 1. SCOPE 1.1 This specification covers the type, physical properties and dimensions of Expanded Polystyrene Insulation Board intended for use in Dryvit Exterior Insulation and Finish Systems (EIFS). 1.2 The use of the Expanded Polystyrene Insulation Board covered by this specification is regulated by building codes. 2. APPLICABLE DOCUMENTS 2.1 ASTM Standards: C 578 Standard Specification for Rigid, Cellular Polystyrene Thermal Insulation D 1623 Standard Test Method for Tensile and Tensile Adhesion Properties of Rigid Cellular Plastics D 2863 Standard Test Method for Measuring the Minimum Oxygen Concentration to Support Candle-Like Combustion of Plastics (Oxygen Index) E 84 Standard Test Method for Surface Burning Characteristics of Building Materials E 2430 Standard Specification for Expanded Polystyrene (EPS) Thermal Insulation Boards for Use in Exterior Insulation and Finish Systems (EIFS) 2.2 Dryvit Systems, Inc. Requirements for Insulation Board Suppliers 2.3 Quality Control Standards Requirements 2.3.1 Quality Control Manual and Inspection Procedures for Molders Supplying Dryvit Systems, Inc. 2.3.2 ICC-ES AC12 Acceptance Criteria for Foam Plastic Insulation 2.4 Hold Harmless and Indemnification Agreement for Insulation Board Suppliers 3. TERMINOLOGY 3.1 Description of terms specific to this specification. 3.1.1 Dryvit Exterior Insulation and Finish System (EIFS) - a nonload bearing exterior wall cladding system consisting of an insulation board, an adhesive and/or mechanical attachment of the insulation board to the substrate, an integrally reinforced base coat on the face of the insulation board, a protective finish applied to the surface of the base coat and applicable accessories that interact to form an energy-efficient exterior wall. 3.1.2 EPS - Expanded Polystyrene Insulation Board, which is affixed to the substrate and creates a layer of continuous insulation. 3.1.3 PB System - a class of EIFS where the base coat varies in thickness depending on the number of layers or thickness of reinforcing material. The thickness can range from a nominal 1/16 in (1.6 mm) to 1/4 in (6.4 mm). The reinforcing material is typically glass fiber mesh, which is embedded in the base coat at the time of installation. 3.1.4 PM System - A class of EIFS where the reinforcing material is typically glass fiber mesh, which is applied over the insulation board and mechanically fastened to the substrate. The base coat is applied over the reinforcing mesh at a nominal thickness of 3/16 in (4.8 mm) to 1/4 in (6.4 mm) and contains fiber reinforcement. 4. CLASSIFICATION 4.1 This specification covers Type I Expanded Polystyrene Insulation Board (as defined by ASTM C 578) intended for use in Dryvit Exterior Insulation and Finish Systems (EIFS). 5. ORDERING INFORMATION 5.1 Standard board sizes. The following are nominal dimensions. See Section 8 for dimensions and permissible variations. Specify: 5.1.1 Thickness: 3/4 in (19 mm) min. 5.1.2 Width: 24 in (610 mm) 5.1.3 Length: 48 in (1219 mm) for PB Systems; 96 in (2438 mm) for PM Systems 5.2 Number of pieces and thickness required 5.3 Job name 5.4 Job address 5.5 Shipping address 5.6 Required delivery date 5.7 Contractor name 5.8 Contractor address 5.9 Billing information 5.10 Certificate of Compliance 5.11 Special Shapes

Expanded Polystyrene Insulation Board Specification 5.11.1 In addition to the ordering information required in Sections 5.1 through 5.10 above, dimensioned drawings or sketches shall be furnished for all special shapes. 5.12 All requests for insulation boards larger than the standard sizes or thicker than 4 in (102 mm) listed in Sections 5.1.2 and 5.1.3 above must be approved in writing by Dryvit Systems, Inc. Engineering Services Department. 5.13 EIF System to be used. 6. MATERIALS AND MANUFACTURE 6.1 Insulation board shall be molded closed cell in compliance with ASTM E 2430 and ASTM C 578 Type I. The boards shall be covered by Quality Control Manual and Inspection Procedures for Molders Supplying Dryvit Systems, Inc. or an ICC-ES report demonstrating compliance to the requirements of ICC-ES AC10. 6.2 Insulation board shall meet the oxygen index, flammability and smoke development requirements of this specification. See Table I. The boards shall be covered by third party certification of flame spread and smoke development requirements. 7. PHYSICAL REQUIREMENTS 7.1 Inspection Requirements 7.1.1 In accordance with the Third Party Certification and Quality Assurance Program. Third party certification shall include ASTM C 578, ASTM E 2430, and flame spread/smoke development. 7.1.2 As otherwise deemed necessary by Dryvit Systems, Inc. 7.1.3 Physical properties shall be in accordance with Table I. Tensile strength values are only required to be evaluated at the beginning of the program. 7.2 Qualification Requirements 7.2.1 All dimensional requirements are described in Section 8. 7.2.2 All workmanship, finish and appearance requirements are described in Section 9. 7.2.3 Combustibility Characteristics - Insulation board is an organic material and is, therefore, combustible. It should not be exposed to flames or other ignition sources. The values obtained by ASTM D 2863 and ASTM E 84/UL723 do not necessarily indicate or describe the fire risk of the materials in end use configuration and are used in this specification primarily to distinguish between insulation formulated with flame retardants and those not so formulated. 7.2.4 Molded billets shall be dimensionally stable prior to being cut into boards or special shapes. Molded billet conditioning shall comply with ASTM E 2430. NOTE: Suppliers furnishing insulation board or shapes conditioned under ASTM E 2430 Section 4.1.9.2 shall advise Dryvit Systems, Inc. and the Third Party Certification and Quality Assurance Agency in writing. The Block Molders plant shall be inspected by the Third Party Certification and Quality Assurance Agency and approved by Dryvit Systems, Inc. prior to the use of this conditioning method. 8. DIMENSIONS AND PERMISSIBLE VARIATIONS 8.1 Insulation board covered by this specification shall conform to the nominal dimensions in Section 5.1. 8.2 Dimensional Tolerances: Length: +/-1/16 in (+/- 1.6 mm) Width: +/-1/16 in (+/- 1.6 mm) Thickness: 3/4 in (19 mm) to 1 in (25 mm) + 1/16 in (+/- 1.6 mm); greater than 1 in (25 mm) +/-1/16 in (+/- 1.6 mm) 8.3 Edge Trueness - Unless otherwise specified and approved by Dryvit Systems, Inc., insulation board shall be furnished with true edges. Edges shall not deviate more than 1/32 in (0.8 mm) in 12 in (305 mm). 8.4 Face Flatness - Insulation board shall be furnished flat and shall not exhibit any bowing of more than 1/32 in (0.8 mm) in the length. 8.5 Squareness - Insulation board shall not deviate from squareness by more than 1/32 in (0.8 mm) in 12 in (305 mm) of total length or width. 9. WORKMANSHIP, FINISH AND APPEARANCE AT TIME OF DELIVERY 9.1 Defects - Insulation board shall have no defects that will adversely affect its service qualities. It shall be of uniform texture and free from foreign inclusions, broken edges or corners, slits or objectionable odors. 9.2 Crushing and Depressions - Insulation board shall have no crushed or depressed areas on any surface exceeding 1/16 in (1.6 mm) in depth on more than 5% of the total surface area. 9.3 Voids - Insulation board shall have no more than 8 voids having dimensions larger than 1/8 in (3.2 mm) x 1/8 in (3.2 mm) x 1/8 in (3.2 mm) per 8 ft 2 (0.74 m 2 ) of surface area. 9.4 Projections - Insulation board shall be free of surface projects or wire marks in excess of 1/16 in (1.6 mm). 2

Expanded Polystyrene Insulation Board Specification 10. SAMPLING AND INSPECTION 10.1 Sampling shall be in accordance with the Third Party Certification and Quality Assurance Program. 10.2 As otherwise deemed necessary by Dryvit Systems, Inc. 11. REJECTION 11.1 Material that fails to conform to the requirements of this specification shall be rejected. 11.1.1 Rejection shall be reported in writing within five (5) days to the producer or supplier and Dryvit Systems, Inc. 11.2 The insulation board supplier may resubmit rejected materials after removal of that portion not conforming to this specification. 11.2.1 The reinspection and resubmittal shall be completed within three (3) days of notification by telephone or written communication. 12. CERTIFICATION 12.1 Upon request, certification of compliance with this specification shall promptly be forwarded to Dryvit Systems, Inc. or their designee. NOTE: See Appendix A for sample certification format. 13. PRODUCT MARKING 13.1 Insulation boards shall be marked (stamped) in accordance with the requirements of this section. 13.1.1 Each board shall be marked on one edge. 13.1.2 In addition, one board in each package shall be marked on both faces. 13.2 Stamp design and layout shall be in accordance with the requirements of the applicable building code. NOTE: Suppliers may add their company name if they so desire. 14. PACKAGING 14.1 All insulation boards shall be packaged in polyethylene bags as required by Dryvit Systems, Inc. 14.2 Alternate methods of packaging shall be submitted to Dryvit Systems, Inc. and approved in writing prior to use. 14.3 The supplier shall mark the lot number on each package as required. 15. INDEMNIFICATION 15.1 Insulation board supplier shall agree to indemnify and hold harmless Dryvit Systems, Inc. for any loss, cost or damage incurred by Dryvit Systems, Inc. as a result of the Insulation Board Supplier s and/or the insulation board s failure to meet these specifications. Information contained in this specification conforms to Dryvit Systems, Inc. s requirements as of the date of publication of this document. To ensure that you are using the latest, most complete information, contact Dryvit Systems, Inc. at: (401) 822-4100 3

EXPANDED POLYSTYRENE (EPS) INSULATION BOARD SPECIFICATIONS TABLE I Properties and Requirements of EPS for Use in Dryvit EIFS Classification (ASTM C 578) Type 1 Density, lb/ft 3 (kg/m 3 ) Thermal Resistance of 1.00 in (25 mm) thickness, min. F ft 2 h/btu (K m 2 /W) 40 F (4.4 C) 75 F (23.9 C) 0.95 (15.2) min. 1.25 (20.0) max. 4.00 (0.70) 3.60 (0.63) Compressive strength, min., psi (kpa) 10.0 (69) Tensile strength, min., psi (kpa) 15.0 (103) Flexural strength, min., psi (kpa) 25.0 (172) Water vapor permeance of 1.00 in (25 mm) thickness, max., perm (ng/pa s m 2 ) 5.0 (287) Water absorption by total immersion, max., volume % 4.0 Dimensional stability (change in dimensions), max. % 2.0 Oxygen index, min., volume % 24.0 Flame spread, max. 25.0 Smoke development, max. 450 Board thickness, Class PB and PM Maximum Minimum Board width, max. Class PB Class PM See Note* 3/4 in (19 mm) 24 in (610 mm) 24 in (610 mm) Board length, max. Class PB 48 in (1219 mm) Class PM 96 in (2438 mm) * NOTE: Contact Dryvit System, Inc. Engineering Department for thicknesses exceeding 4 inches. 4

APPENDIX A (To be typed on supplier s letterhead.) Dryvit Systems, Inc. Attention: RE: Insulation Board Certification Project Name: Address: City, State, Zip: To Whom It May Concern: This letter is to certify that the Expanded Polystyrene Insulation Board supplied to the abovereferenced project meets the requirements of the current edition of the Dryvit Specification for Expanded Polystyrene (EPS) Insulation Board published by Dryvit Systems, Inc. Company Name Owner, Principal or Corporate Officer Authorized Signature Title Date cc: Distributor Contractor Dryvit Systems, Inc. 800-556-7752 www.dryvit.com For more information on Dryvit Systems or Continuous Insulation, visit these links. Printed in USA. Issued 2-3-16 5 Dryvit Systems, Inc. 1992