VERA VERIFICATION STATEMENT



Similar documents
VERA VERIFICATION STATEMENT

European Technical Assessment ETA-15/0652 of 27/10/2015

Working Party on Control of Medicines and Inspections. Final Version of Annex 15 to the EU Guide to Good Manufacturing Practice

European Technical Assessment ETA-10/0153 of 10/06/2015

Solar air collectors for industry and larger halls S Ø. Efficient dehumidification and air heating for free...

ETV Joint Verification Statement

ETV Joint Verification Statement

Temporary Batch Plants

THE ENVIRONMENTAL TECHNOLOGY VERIFICATION PROGRAM

European Technical Assessment ETA-15/0028 of 23/02/2015

Eurovent Certification for Air Handling Units : Five Energy Efficiency classes to make the right choice

ITE. Indirect calorifier ITE - 400/500/600/750/1000. Installation, User and Service Manual. Innovation has a name.

CCS achievements at TCM. Managing Director Frank Ellingsen

Storm Drain Inlet Protection

HEPA FILTER DEFECTS ARE COMMON

ETV Joint Verification Statement

GENERAL GUIDANCE FOR INSPECTORS ON HOLD-TIME STUDIES

GUIDELINES FOR IMPLEMTING GMP IN FOOD PROCESSING

ABC CIRCUITS 10 Circuit Drive Circuit Town, IN SLUG CONTROL PLAN

DHI DANETV Test Centre Quality Manual

Prevent Blockages in the Sanitary Sewer System

RULE ORGANIC COMPOUNDS - WASTEWATER COLLECTION AND SEPARATION SYSTEMS

The German Bio-Siegel

THE ENVIRONMENTAL TECHNOLOGY VERIFICATION PROGRAM ANALYSIS OF TOTAL COLIFORMS AND E. COLI IN DRINKING WATER

FAST Owner s Manual. MicroFAST NitriFAST HighStrengthFAST RetroFAST

IAC 7/2/08 Agriculture and Land Stewardship[21] Ch 44, p.1

Spillemyndigheden s change management programme. Version of 1 July 2012

PUBLICATIONS. Introduction

TYPE CERTIFICATION OF WIND TURBINES

The Use and Application of the Benchmarking Assessment Tool for the Recovery and Recycling of Used Lead Acid Batteries in India

Prescriptive, Custom, New Construction and Data Center

UDOT SPILL PREVENTION and RESPONSE PLAN for CONSTRUCTION SITES

As simple as and as secure as postal mail.

STREAMLINE. Products for the Pure Water Cleaning Industry INSTRUCTION MANUAL

FAST Owner s Manual. MicroFAST NitriFAST HighStrengthFAST RetroFAST

A Guide to Specifying Reed Beds and Constructed Wetland Systems

Facts about the production of Poultry Meat in Denmark 4. July 2014

Revised April (May) 2015

Fuel Treatment and Conditioning Systems


OWNER S MANUAL MODEL NUMBERS M-6-A M-8-A M-1050-A M-1200-A M-2000-A

How To Get A Passive House

Portable Compressors MOBILAIR M122 With the world-renowned SIGMA PROFILE Free air delivery 11.1 m³/min.

SOLICITATION STATEMENT OF WORK CONSTRUTING OVERHEAD ROOF COVER ON THE TENT AT DTFS. US. Embassy, Sawan Street, Himyar Zone

Marine after-treatment from STT Emtec AB

OMCL Network of the Council of Europe QUALITY MANAGEMENT DOCUMENT

National Precast Concrete Association

European Technical Approval ETA-12/0500

European Technical Approval ETA-10/0153

Managing Heat Stress in Poultry

SEPARATING DUST PARTICLES USING AN AERODYNAMIC DEDUSTER

TETRA Chemicals Europe

SE-10 STORM DRAIN INLET PROTECTION. Objectives

SWIMMING POOL AIR-HANDLING UNITS KU-DB Series

Permit with introductory note

PRODUCT SELECTOR Pollution Control, Pumping and Rainwater Harvesting Systems

HUBER Vacuum Rotation Membrane VRM Bioreactor

European Technical Assessment ETA-16/0277 of 19/05/2016

SECTION EARTH MOVING

MOBILE HOME LAW. Revised November 2001

Installation & Operating Instructions

Mold Alert... Operation Manual P0270

European Technical Approval ETA-10/0124

IMPACT OF TRAUMA HELICOPTERS ON AIR QUALITY INSIDE HOSPITALS. J.F.W. Koopmans Peutz bv, Mook, The Netherlands,

ETV Joint Verification Statement

Which filter class for supply air is required in a typical HVAC system?

Tips for a Successful Diesel Retrofit Project

PROPAK AquaBio Complete Water Restoration Systems

MATERIAL SAFETY DATA SHEET High Pressure Laminate Fire Retardant

Hackney Biomass Boiler Information Request Form

Retardants Inc. The Decision You Make May Save A Life! 123 Columbia Court North Suite 201 Chaska, MN 55318

Microbiological Laboratory Quality Assurance

Disposal of Fats, Oils, Grease and Food Waste Best Management Practice for Catering Outlets

MITSUBISHI MOT PROTECTION YOUR TERMS AND CONDITIONS

Organic Action Plan for Denmark. Working together for more organics

ENVIRONMENTAL MANAGEMENT ACCOUNTING IMPLEMENTATION GUIDELINE

Troubleshooting Salt Generators

Concrete Waste Management

1. IDENTIFICATION OF THE SUBSTANCE/PREPARATION AND OF THE COMPANY/UNDERTAKING.

British Domestic Drivers Hours Regulations

ORDINANCE NO

GFE pretreatment/nix Concept Pre-treatment of biomass for anaerobic digestion

Instruction Manual. Window Wiper AFW900. (Read carefully before use)

Safety Data Sheet UN-GHS (Rev.4) (2011) Update: Version: 1.2

BEST PRACTICES IN LEAK DETECTION AND REPAIR (LDAR) PROGRAMS. November 06, 2014 By: François Thibodeau, Eng.

Managing Systems for Tilapia Culture

C18 ACERT Fire Pump Tier bkw/ rpm

Official Journal of the European Union L 182/19 DIRECTIVES

IMPORTANT SAFETY RULES TO FOLLOW

Operation manual and Spare parts list EL PUMP. November

Specification. Indoor Air Quality Management

UV Disinfection Systems A Series. Main Applications: Drinking Water, Process Water, Warm Water / Legionellae. IT T Industries Engineered for life

Risø-R-1512(EN) Green Technological Foresight on Environmental Friendly Agriculture: Executive Summary

AIR CONDITIONING MAINTENANCE

What is a Tracking Chart?

Executive Order amending the Executive Order on the Publication of the Danish Building Regulations 2010 (BR10) 1)

GUIDANCE FOR DEVELOPMENT OF SPILL AND SLUG PREVENTION CONTROL PLANS AND FACILITIES FOR THE CITY OF ATTLEBORO SEWER USERS

College ter Beoordeling van Geneesmiddelen / Medicines Evaluation Board. Graadt van Roggenweg AH Utrecht The Netherlands

Creating Added Value with EMAS

How Does Fortron Air Conditioning Treatment Work?

Transcription:

VERA VERIFICATION STATEMENT VERIFICATION OF ENVIRONMENTAL TECHNOLOGIES FOR AGRICULTURAL PRODUCTION It is hereby stated (verified) that Technology: Farm AirClean BIO Flex 2-stage (with maximum capacity of 3.600 m 3 air m -2 front surface h -1 ) Manufactured by: SKOV A/S has been tested according to the VERA test protocol for Air Cleaning Technologies version 1, September 2010. The following main results have been documented through the test: Verified environmental efficiency: Ammonia emission reduction efficiency at 88 % when applied for pigs Odour emission reduction efficiency at 74 % when applied for pigs Total dust emission reduction efficiency at 70 % when applied for pigs Dust, PM2,5 emission reduction efficiency at 87 % when applied for pigs Dust, PM10 emission reduction efficiency at 79 % when applied for pigs Verified operational stability: The Farm AirClean BIO Flex has demonstrated a satisfactory operational stability Issued on 2015-05-28 Mr. Thomas Bruun, Managing Director, ETA-Danmark A/S

Exemption of liability ETA-Danmark A/S does not endorse, certify or approve technologies. VERA verifications are based on an evaluation of the technology performance under specific, predetermined criteria and the appropriate quality assurance procedures. VERA as a representative for the Danish EPA, the German Federal Ministry of Food, Agriculture and Consumer Protection and the Dutch Ministry of Infrastructure and Environment make no expressed or implied warranties as to the performance of the technology and do not certify that a technology will always operate as verified. The end user is solely responsible for complying with any and all applicable federal, state, and local requirements. Further the end user must be aware that the countries involved in VERA are having different legal requirements which will influence the status and use of this verification statement in each country. Page 2 of 9

The VERA Organisation VERA Verification of Environmental Technologies for Agricultural Production is an international organisation for test and verification of environmental technologies for agricultural production. VERA is established as a co-operation between the Danish Environmental Protection Agency, the Dutch Ministry of Infrastructure and Environment and the German Federal Ministry of Food, Agriculture and Consumer Protection. The purpose of VERA is to enhance a well-functioning market for environmental technologies to increase the environmental protection of agricultural production by substantially accelerating the acceptance and use of improved and cost-effective environmental technologies. VERA verifies the performance of technologies by carrying out tests according to pre-defined test protocols. A VERA Verification Statement secures validated documentation for the environmental efficiency and operational stability of the technology and is an important step in introducing the technology to the market. Based on information from the test reports, the VERA Verification Statement gives a general and short description of the technology, its principle of operation, and the main results and conclusions from the VERA test. Applicant Data Technology type Applied for Technology name Company Contact person Address Website Biological air with maximum capacity of 3600 m 3 air m -2 front surface h -1 for pigs Reduction of ammonia, odour and dust from exhaust air of forced-ventilated animal housing systems Farm AirClean BIO Flex 2-stage SKOV A/S Lise Bonne Guldberg Hedelund 4, DK-7870 Roslev, Denmark www.skov.com Phone +45 7217 5555 E-mail Test institute lgu@skov.dk Pig Research Centre (VSP), Danish Agriculture and Food Council, Denmark and LUFA Nord-West, Jägerstrasse 23 27, DE-26221 Oldenburg, Germany Page 3 of 9

Technology Description The Farm AirClean BIO Flex 2-stage is a biological air cleaning system consisting of two rows of moistened cellulose pads, which are positioned vertically. Air is cleaned by a biological process that works by exhaust air being removed from the house through cleaning filters sprinkled with recirculated water. The unwanted substances in the air are absorbed by the water or decompose when they come in contact with the water and the layer of bacteria on the cleaning filters. Both the first and second stage of the air consists of 15 cm thick cellulose packed filters. Each filter is 2.0 m high. The width of the filters is designed according to the maximum ventilation rate and the maximum capacity of the air cleaning system. The air cleaning system has a maximum capacity of 3600 m 3 air m -2 front surface h -1 for pigs. In order to avoid accumulation of inhibitory compounds, water exchange control is based on measurements of conductivity. The two filter steps are sprinkled with water that is recirculated from a sump below each filter step. Clean water is fed into the sump below the second filter step, from which it over-flows into the sump below the first filter step. Addition of fresh water is controlled by the water level in the sump below the first filter step. All water from the air is discharged from the sump below the first filter step and is either collected or directed to the slurry storage tank. The discharge of water from the sump below the first filter step is regulated by the conductivity in the sump below the second filter step. An automatic washer washes the first filter at regular intervals. This removes dust and redundant biomass. A perforated plate is installed in front of the first filter as a flow straightener to ensure a uniform air distribution and to preseparate dust. Test Design The Farm AirClean BIO Flex 2-stage was tested in the Netherlands by LUFA Nord-West and in Denmark by the Pig Research Centre (VSP) in accordance with the VERA Test protocol for Air Cleaning Technologies. The two tests sites are in the following named test site A and B, respectively. In each country the biological air was tested at one farm location by installing the air in a pig finishing house. Measurements of ammonia, odour and dust were performed during an 8 weeks summer period and an 8 weeks winter period. Additionally, key parameters were continuously logged and the system was monitored over a period of one year to create a basis for an evaluation of the operational stability of the system In the test by LUFA (testsite A) the number of pig places was 900. measurements were carried out from August to September 2013 and the winter measurements were carried out from December 2013 to February 2014. The maximum capacity was 3600 m 3 air m -2 front surface h -1 for pigs and the width of the filter was 12,6 m. In the test by VSP (test site B) the number of animals in the house was 350 pigs. measurements were carried out from August to September 2010 and the winter measurements were carried out from February to April 2011. The maximum capacity was 3600 m 3 air m -2 front surface h -1 for finishing pig units and the width of the filter was 5.0 m. The two test reports from the two tests in combination constitute the foundation for a full VERA test. Page 4 of 9

Test Results Environmental Efficiency Ammonia reduction Table 1 presents the ammonia concentration measured at test the site. Table 2 presents the ammonia reduction efficiency of the Farm AirClean BIO Flex 2-stage for the test site and the overall mean for application at finishing pig units. Table 1: Ammonia concentration before and after the air during the summer and winter test periods together with ammonia removal efficiency. Test site A Ammonia concentration (ppm) 40,1 2,9 42,2 0,8 Ammonia reduction (%) 91,7 % 98,0 % Test site B Ammonia concentration (ppm) 5.97 1,9 a 17,5 1.35 b Ammonia reduction (%) 68,2 % 92,3 % a) Limit of quantification (LOQ) was 1.08 ppm b) Limit of quantification (LOQ) was 1.35 ppm Table 2: Reduction percentages of ammonia by the air given for test site, and as the overall mean. Ammonia reduction (%) Test site A Test Site B Mean 91,7 % 68,2 % 80,0 % 98,8 % 92,3 % 95,6 % Overall 94,8 % 80,3 % 87,6 % The ammonia emission was on average reduced with 88 %, when air was passed through the filter. Page 5 of 9

Odour reduction Table 3 presents the odour concentration measured at test site. Table 4 presents the odour reduction efficiency of the Farm AirClean BIO Flex 2-stage for the test site and the overall mean for application at finishing pig units. Table 3: Odour concentration before and after the air during the summer and winter test periods. Test site A Odour concentration (OUE/m 3 ) 338 114 1069 285 Test site B Odour concentration (OUE/m 3 ) Average of 8 measurement days 229 56 542 109 Table 4: Reduction percentages of odour by the air given for the test site, and as the overall mean. Odour reduction (%) Test site A Test Site B Mean 66 % 76 % 71 % 73 % 80 % 77 % Overall 70 % 78 % 74 % The odour emission was on average reduced with 74 %, when air was passed through the filter. The average odour concentration was reduced to below 300 OU/m 3 Page 6 of 9

Dust reduction The total dust concentration was measured at one test site during both summer and winter (Table 5). The total dust emission reduction is presented in table 6. Table 5: Total dust concentration measured over 24-hour periods at one test site before and after the air during the summer and winter test periods. N=2 on each measurement day. Test site A Total dust (mg/m 3 ) 0,97 0,16 2,97 0,60 Test site A Dust, PM 2,5 (mg/m 3 ) 0,24 0,02 0,41 0,08 Test site A Dust, PM 10 (mg/m 3 ) 0,39 0,08 0,74 0,18 Test site B Total dust (mg/m 3 ) 1,4 0,32 0,47 0,28 Test site B Total dust (mg/m 3 ) 1,6 0,7 2,3 0,95 Table 6: Reduction percentages of total dust in the air given for each summer and winter measurement day and as a mean for each season and the overall mean. Dust reduction (%) Test site A Test Site B Total Mean Dust, PM 2,5 Dust, PM 10 83,9 % 57,9 % 70,9 % 92,4 % 80,9 % 79,9 % 58,7 % 69,3 % 81,3 % 76,2 % Overall 81,9 % 58,3 % 70,1 % 86,9 % 78,6 % The air removed dust from the air passing the filters. The air showed a total dust removal efficiency of 70 %. Operational Stability The test proved that the air cleaning system had satisfying operational stability. The Farm AirClean BIO Flex 2-stage is delivered with a complete user manual, which describes relevant directions for system operation, maintenance and safety. The air cleaning process is monitored by a computer which monitors consumption and alarm limits (water level, conductivity, ph, washer, pressure, leakage, drainage). In addition to weekly inspections of the filter by the user, the test showed a periodic need for manual washing of the filter. Page 7 of 9

The functionality and the operational stability of the Farm AirClean BIO Flex system can be checked by relevant authorities by inspecting the run time, EC and water supply. These parameters can be controlled by checking the log files from the computer that regulate and monitors the system. As a starting point, the system should continuously consume water and keep EC below 15 ms/cm in filter 2 with reservation for temporary stops in relation to maintenance and service. A continuously addition of water is expected when house air is passing the air in order to compensate for humidification and drainage of water. The volume of water consumed will depend on operation and management of the house, batch plan of pigs, ventilation etc. Identified Side Effects None observed. Additional Results None observed. Additional Information No additional information. Test Institutes Pig Research Centre (VSP), Danish Agriculture and Food Council, Axeltorv 3, 1609 København V, Denmark. Tel: +45 3339 4000, E-mail: vsp-info@lf.dk LUFA Nord-West, Jägerstrasse 23 27, DE-26221 Oldenburg, Germany. Tel: +49 441 801 821, E-mail: lufa@lufa-nord-west.de Page 8 of 9

Validity and Terms of Use Validity This VERA Verification Statement is only valid for the specific verified product/technology and the tested animal category. There is no time limit for the validity of this VERA Verification Statement as long as the product/technology stays unmodified. ETA-Danmark A/S can, however, at any time invalidate the VERA Verification Statement if it is found to be misused or if significant modifications have been made to the product/technology that are estimated to have a negative effect on the environmental efficiency or operational stability. In regard to the latter ETA- Danmark A/S can require that a new VERA test should be performed. Terms of Use The use of this VERA Verification Statement must be in compliance with these terms: SKOV A/S must inform ETA-Danmark A/S if any modifications are applied to the technology that can significantly influence the environmental efficiency and/or the operational stability This verification cannot be considered an endorsement, approval, authorization or warranty of any kind, and the performance parameters provided cannot be extended to other applications or to other technologies SKOV A/S agrees not to use this VERA Verification Statement, the test reports, or to refer to those for any other technology than the one specified in the statement. The VERA Verification Statement will be made available for public access at the ETA-Danmark website: www.etadanmark.dk. All other information obtained or produced during the verification process is considered confidential and will not be made available for others than the part owning the intellectual property rights. Contact Information This VERA Verification Statement is issued by ETA-Danmark A/S Göteborg Plads 1 DK-2150 Nordhavn Denmark Phone: (+45) 72 4 59 00 E-mail: info@etadanmark.dk Web: www.etadanmark.dk Page 9 of 9