1 GREENGUARD Environmental Institute 2211 Newmarket Parkway, Suite 110 Marietta, GA Specification Indoor Air Quality Management This Master Specification section is intended for use in preparation of a project specification covering indoor air quality requirements. The specification includes the requirements of LEED-NC, LEED-EB and includes specifications for construction products, construction site management, construction sequencing, HVAC operation during construction, product installation, building flush-out and IAQ testing. Indoor Air Quality Management GREENGUARD Environmental Institute
2 SECTION INDOOR AIR QUALITY MANAGEMENT This section includes editing notes to assist the user in editing the section to suit project requirements. These notes are included as hidden text, and can be revealed or hidden by one of the following methods: Microsoft Word: From the pull-down menus select TOOLS, then OPTIONS. Under the tab labeled VIEW, select or deselect the HIDDEN TEXT option. Corel WordPerfect: From the pull-down menus select VIEW, then select or deselect the HIDDEN TEXT option. PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Product requirements for indoor construction and finishing materials. 2. Final Construction Products List. 3. Construction site management. 4. Indoor Environmental Consultant qualifications. 5. Scheduling and product installation sequencing. 6. Operation of HVAC systems during construction. 7. Product installation. 8. Building flush out. 9. Indoor air quality testing. 10. Documentation and reporting. 1.2 REFERENCES A. American Conference of Government Industrial Hygienists (ACGIH). B. American National Standards Institute/American Society of Heating, Refrigeration, and Air- Conditioning Engineers (ANSI/ASHRAE): Method of Testing General Ventilation Air-Cleaning Devices for Removal Efficiency by Particle Size Thermal Environmental Conditions for Human Occupancy Ventilation for Acceptable Indoor Air Quality Ventilation and Acceptable Indoor Air Quality for Low-Rise Residential Buildings. Indoor Air Quality Management GREENGUARD Environmental Institute
3 C. GREENGUARD Environmental Institute (GREENGUARD) - Indoor Air Quality Certification Program. D. U.S. Green Building Council (USGBC) - Leadership in Energy and Environmental Design (LEED) 2009 for New Construction and Major Renovations. D. U.S. Green Building Council (USGBC) - Leadership in Energy and Environmental Design (LEED) 2009 for Commercial Interiors. E. Sheet Metal and Air Conditioning Manufacturer s Association International (SMACNA) F. United States Environmental Protection Agency (EPA): 1. Compendium of Methods for the Determination of Air Pollutants in Indoor Air. 2. National Ambient Air Quality Standard, Code of Federal Regulations, Title 40, Part DEFINITIONS A. Dry Products: Products used in a solid state, including gypsum board, carpet, acoustical panels and tiles, and textiles. B. MERV: Minimum Efficiency Reporting Value. C. Priority Products: Products known to be high chemical emitters, long term emitters, and those expected to present emissions in high amounts (high surface area). D. Threshold Limit Value (TLV): Industrial Work Place Standard as defined by ACGIH. E. Wet Products: Products used in a liquid or semi-liquid state, including adhesives, joint sealers, paints, and coatings. 1.4 SUBMITTALS A. Final Construction Products List: 1. Submit list of proposed indoor construction and finishing products. 2. Include strategies for minimizing use of wet products. 3. Obtain approval by [Architect] [Interior Designer] [Commissioning Agent] [ ] prior to installation of products. B. Indoor Air Quality Test Report: 1. Provide copies of Indoor Air Quality Test Report from Indoor Environmental Consultant. 2. Include in report: a. Study design including methodology for determination of air sampling locations and duration of sampling. b. Summary of sampling and analytical methods employed. c. Copy of field sampling logs. Indoor Air Quality Management GREENGUARD Environmental Institute
4 1.5 QUALITY ASSURANCE d. Summary of methods and results used to determine that ventilation system was started at normal daily start time and operated at minimum outside airflow rates for occupied mode for duration of air testing. e. Laboratory analytical data for each contaminant and summary table showing compliance with specified criteria. A. Provide written notification of product requirements to subcontractors and suppliers of interior construction and finishing products. B. Indoor Environmental Consultant Qualifications: 1. [Owner will] [Contractor shall] employ and pay for an Indoor Environmental Consultant to perform specified indoor air quality testing. 2. Minimum 5 years experience in conducting indoor environmental quality evaluations of non-industrial buildings. 3. Retain Certified Industrial Hygienist (CIH) on staff to review and sign test reports. 1.6 DELIVERY, STORAGE AND HANDLING A. Storage Area: 1. Designate secure storage area to facilitate protection of stored absorptive products. 2. Clearly identify storage area. Keep dry, clean, and orderly; prevent contamination of products. 3. Monitor storage areas for contamination; correct problems and implement preventative measures. B. Products: 1. Protect absorptive products from moisture damage before, during, and after installation. 2. Immediately remove products exhibiting stains, mold, mildew, or other evidence of water or moisture damage from site. PART 2 - PRODUCTS 2.1 GENERAL A. Interior Construction and Finishing Products; in purchasing products, give preference to: 1. Products designed and manufactured in manner to produce least harmful and irritating effects. 2. Products certified by GREENGUARD Environmental Institute as Low Emitting. For products that are not GREENGUARD Certified, provide a test, which at maximum is performed one year prior to installation, to ensure conformance to GREENGUARD standard emission values. 3. Products providing lowest practical yet technologically achievable emissions of particulates and chemical vapors, as defined in following paragraphs. B. Maximum Chemical emission Values for Products In Commercial or Retail Buildings: Indoor Air Quality Management GREENGUARD Environmental Institute
5 1. Emission rate calculations: Assume 32 cubic meters as volume for determination of product loading. 2. Product emission rates and modeling for predicted exposure concentrations: As measured in milligrams/square meter per hour (mg/m 2 hr) at anticipated loading (square meter/cubic meter [m 2 /m 3 ] within building. Predicted indoor concentrations shall be based on building modeling parameters of 0.72 air changes per hour (ACH). The product shall produce indoor air concentration levels less than the amounts specified for each substance within seven (7) days of installation. 3. Total VOC emission rate: Maximum total volatile organic compounds (VOC) of 0.05 milligrams/cubic meter (mg/m 3 ). 4. Total aldehydes: Maximum 0.1 parts per million (ppm). 5. Formaldehyde: Maximum 0.05 parts per million (ppm) Phenylcyclohexene (4-PC): Maximum milligrams/cubic meter (mg/m 3 ) or 0.1 parts per billion (ppb). 7. Styrene: Maximum 0.07 milligrams/cubic meter (mg/m 3 ). 8. For individual Volatile Organic Compounds (VOCs) not listed above: Shall produce an air concentration level less than 1/10th of the Threshold Limit Value (TLV) at the anticipated product loading in the building within seven (7) days of installation. 9. Regulated pollutants: Maximum air concentration as promulgated by National Ambient Air Quality Standard for primary and secondary outdoor air pollutants. 10. Identified carcinogens and reproductive toxins: Below levels of no significant risk according to evaluation protocols established by EPA or approved State and public health organizations. B. Maximum Chemical and Particle emission Values for Products In Educational, Daycare, Healthcare, or Otherwise Sensitive Environments: 11. Emission rate calculations: Assume 231 cubic meters as volume for determination of product loading. 12. Product emission rates and modeling for predicted exposure concentrations: As measured in milligrams/square meter per hour (mg/m 2 hr) at anticipated loading (square meter/cubic meter [m 2 /m 3 ] within building. Predicted indoor concentrations shall be based on building modeling parameters of 0.9 air changes per hour (ACH) and a 0.9 ventilated volume fraction. The product shall produce indoor air concentration levels less than the amounts specified for each substance within seven (7) days of installation except for formaldehyde. Formaldehyde criteria are established so that emission levels reach ppm (13.5 ppb) within 14 days of installation (meeting CA 1350 requirements). 13. Total VOC emission rate: Maximum total volatile organic compounds (VOC) of milligrams/cubic meter (mg/m 3 ). 14. Total aldehydes: Maximum parts per million (ppm). 15. Formaldehyde: Maximum parts per million (ppm) within 14 days of installation. 16. Total Phthalates: Maximum 0.01 milligrams/cubic meter (mg/m 3 ). Total phthalates are defined as the total response of a specific target list of phthalates including dibutyl (DBP), diethylhexyl (DEHD), diethyl (DEP), butylbenzyl(bbp), di-octyl (DOP), and dimethyl (DMP) phthalates (conducted using a modified phthalate specific analytical method, OSHA 104). 17. Total Particles: Maximum 0.02 milligrams/cubic meter (mg/m 3 ). This is applicable only to fibrous, particle-releasing products with exposed surface area in air streams (determined using a forced air test with specific test method). 18. For individual Volatile Organic Compounds (VOCs) not listed above: Shall produce an air concentration level less than 1/100 of the Threshold Limit Value (TLV) and less than ½ of the California Chronic REL at the anticipated product loading in the building within seven (7) days of installation. Indoor Air Quality Management GREENGUARD Environmental Institute
6 PART 3 - EXECUTION 3.1 CONSTRUCTION SITE MANAGEMENT A. If weather or plumbing leaks result in interior of building becoming wet: 1. Ensure that building is properly dried out prior to installation of any additional materials into the space. 2. Inspect installed materials for mold and mildew. 3. Affected materials less than 10 square feet in area: Remediate materials according to accepted industry practices. 4. Affected materials 10 square feet or more in area: Employ certified remediation firm to remove materials from site. B. For projects incorporating new construction in an existing space, follow the procedures outlined in the Sheet Metal and Air Conditioning National Contractors Association (SMACNA) IAQ Guidelines for Occupied Buildings Under Construction, Chapter 3, also see section 3.3 below. 3.2 SCHEDULING AND PRODUCT INSTALLATION SEQUENCING A. Schedule shipment and delivery of products based on actual construction progress to minimize time products are stored on site. B. Prepare and staff building site for delivery of products. C. Inspect products upon delivery for conformance to Final Construction Materials List and to ensure that they are free from water and moisture damage and properly stored. D. Use the least practical amount of wet materials. E. Do not install dry materials until wet materials have been installed and allowed to dry to greatest extent practical. F. Choose drying times so that specified pollutant emission rates are achieved prior to installation of dry materials. G. Install solvent containing materials during periods during which building is unoccupied. Schedule installation as early as possible during construction to allow for maximum offgassing prior to building occupancy or re-occupancy. H. Install high-voc emitting products prior to installation of porous and fibrous products, or protect with polyethylene sheeting, properly sealed. I. Complete installation of interior finishing materials two to four weeks prior to building occupancy. Continuously flush out building with fresh air for two to four weeks. J. Provide temporary ventilation during touch-up operations; extend building flush-out for minimum of four days after touch-up is complete. 3.3 OPERATION OF HVAC SYSTEMS DURING CONSTRUCTION IN OCCUPIED BUILDINGS A. Depressurize construction area at rate at least 10 percent greater than rate of supply or pressurize existing spaces, whichever is more feasible. B. Erect supplemental containment barriers if pressurization is not adequate to control construction dust and odors in occupied areas. Indoor Air Quality Management GREENGUARD Environmental Institute
7 C. Ensure that construction equipment and staging areas are away from air intakes for existing construction. D. Temporarily seal intake dampers for existing space when high-emitting construction activities are performed near outdoor air intakes for existing construction. E. During demolition or construction in existing spaces: 1. Do not operate building HVAC systems in affected areas. 2. Temporarily seal supply and return openings with plastic sheeting. 3. If system must be operational during demolition or construction, install temporary MERV 8 filters in return openings in accordance with LEED Guidelines; maintain in clean condition. 3.4 BUILDING FLUSH-OUT A. If building meets Clearance Criteria immediately following construction, building flush-out is not required. B. Following completion of interior finishes and installation of new furnishings, flush building with 100 percent clean outdoor air for two to four weeks prior to occupancy. If time does not permit a two to four week flush-out period, the design and construction team shall designate whatever time is available for building flush (even if it is as minimal as 24 hours). C. Install new MERV 13 filtration media prior to beginning the flush-out procedure. D. After flush-out, install new MERV 13 filtration media, except for those filters processing only outdoor air. 3.5 INDOOR AIR QUALITY TESTING A. Perform testing after completion of construction and installation of new furnishings, but before Owner occupancy, using protocols established by reputable standard setting or method development organizations such as state and federal agencies and reputable nongovernmental organizations such as the GREENGUARD Environmental Institute or ASTM. B. Conduct testing prior to Owner occupancy but during normally occupied hours. C. Operate building HVAC system at normal daily start and stop times at minimum outside airflow for occupied mode for duration of testing. D. Number of Air Sampling Locations: Minimum of one per 25,000 square feet or for each contiguous floor area, whichever is greater. Include areas with least ventilation and greatest presumed source strength. E. At each location, collect samples at to 6 feet above floor over minimum 4 hour period. F. Demonstrate that contaminant concentrations do not exceed following maximum concentration limits: Contaminant Maximum Concentration Limit Carbon Dioxide * 10,300/ventilation rate Indoor Air Quality Management GREENGUARD Environmental Institute
8 Contaminant Maximum Concentration Limit Carbon Monoxide Total Volatile Organic Compounds (TVOC) Formaldehyde 4-Phenylcyclohexene (4-PCH) Other Individual VOC s Total Aldehydes Total Particles (PM 10) 9 ppm and maximum 2 ppm above outdoor levels Maximum 500 micrograms/cubic meter Maximum 27 parts per billion Maximum 6.5 micrograms/cubic meter Below odor and/or sensory irritation threshold and maximum 1/10 TLV Maximum 100 parts per billion Maximum 50 micrograms/cubic meter * Carbon dioxide monitoring is required only if building is occupied during testing. Ventilation rate is outdoor air requirement per person. Carbon dioxide measurement is differential between indoor and outdoor conditions, based on occupancy type as defined by ANSI/ASHRAE 62.1 and G. For each sampling location where maximum concentration limit is exceeded, conduct additional flush-out with outside air and retest specific contaminant until maximum concentration limit is achieved. Collect samples for retesting from original sampling location. END OF SECTION Indoor Air Quality Management GREENGUARD Environmental Institute
IEQ Management Plan. Denver Museum of Nature and Science ECF Addition
IEQ Management Plan GH Phipps Construction Companies 5995 Greenwood Plaza Blvd., Suite 100 Greenwood Village, Colorado 80111-4710 303.571.5377 PHONE www.ghphipps.com Denver Museum of Nature and Science
Construction Indoor Air Quality Management Plans for LEED. Matt Gregg, PE, LEED AP
Construction Indoor Air Quality Management Plans for LEED Matt Gregg, PE, LEED AP Agenda What is a Construction IAQ Management Plan? What are the LEED Requirements? What is the Mechanical Contractor s
Toward Better Buildings. Resources for Managing IAQ during Construction
Toward Better Buildings Resources for Managing IAQ during Construction 26 BY DONALD WEEKES, WANE A. BAKER, AND JACK SPRINGSTON EEPA estimates that, on a yearly basis, many Americans spend an average of
Radford University. Indoor Air Quality Management Plan
Radford University Indoor Air Quality Management Plan Spring 2015 Introduction Concerns with Indoor Air Quality (IAQ) have increased since energy conservation measures were instituted in office buildings
WATER DAMAGE INVESTIGATION. Massachusetts Gaming Commission 101 Federal Street Boston, Massachusetts
WATER DAMAGE INVESTIGATION Massachusetts Gaming Commission 101 Federal Street Boston, Massachusetts Prepared by: Massachusetts Department of Public Health Bureau of Environmental Health Indoor Air Quality
WATER DAMAGE INVESTIGATION. Massachusetts Department of Public Utilities 1 South Station Boston, Massachusetts
WATER DAMAGE INVESTIGATION Massachusetts Department of Public Utilities 1 South Station Boston, Massachusetts Prepared by: Massachusetts Department of Public Health Bureau of Environmental Health Indoor
LEED PRESENTATION OUTLINE
16902 BOLSA CHICA STREET, SUITE 101 HUNTINGTON BEACH, CA 92649 TELEPHONE (714) 840-8230 FACSIMILE (714) 840-2490 LEED PRESENTATION OUTLINE I. Overview of Green Building and Risks Involved with Sustainability
FEDERAL LEADERSHIP IN HIGH PERFORMANCE and SUSTAINABLE BUILDINGS MEMORANDUM OF UNDERSTANDING
FEDERAL LEADERSHIP IN HIGH PERFORMANCE and SUSTAINABLE BUILDINGS MEMORANDUM OF UNDERSTANDING PURPOSE: With this Memorandum of Understanding (MOU), signatory agencies commit to federal leadership in the
KEY ELEMENTS IN PREVENTING AND MITIGATING MOLD CLAIMS
KEY ELEMENTS IN PREVENTING AND MITIGATING MOLD CLAIMS By Jerome E. Spear, CSP, CIH Effective January 1, 2005, consultants who prepare mold management plans for buildings located in Texas must be licensed
CONSTRUCTION IAQ MANAGEMENT PLAN During Construction
CONSTRUCTION IAQ MANAGEMENT PLAN During Construction The LEED requirements with which this Indoor Air Quality Plan complies are as follows: OVERVIEW EQc3.1 Construction IAQ Management Plan During Construction
NADCA GENERAL SPECIFICATIONS FOR THE CLEANING OF COMMERCIAL HEATING, VENTILATING AND AIR CONDITIONING SYSTEMS
NADCA GENERAL SPECIFICATIONS FOR THE CLEANING OF COMMERCIAL HEATING, VENTILATING AND AIR CONDITIONING SYSTEMS National Air Duct Cleaners Association 1518 K Street, N.W. Suite 503 Washington, DC 20005 (202)
Mold Response and Remediation Plan
1.0 Policy Statement The University of New Haven has developed a mold response and remediation plan in accordance with best practices set forth by the Environmental Protection Agency (EPA), Occupational
MOLD RESPONSE AND REMEDIATION PLAN
MOLD RESPONSE AND REMEDIATION PLAN Prepared By: Triumvirate Environmental Developed: April 2011 Last Revised: March 2015 Program Approval Associate Vice President of Public Safety & Administrative Services
ASBESTOS MANAGEMENT PROGRAM
ASBESTOS MANAGEMENT PROGRAM Prepared By: Triumvirate Environmental Program Approval Developed: August 2011 Updated: June 2015 Associate Vice President of Public Safety & Administrative Services Date Associate
The Finnish Classification of Indoor Environment and Material Emissions
The Finnish Classification of Indoor Environment and Material Emissions Jorma Säteri Finnish Society of Indoor Air Quality and Climate, FiSIAQ Finnish Classification of Indoor Environment 2008 An update
NORMI Professional Guidance for DIY Projects
NORMI Professional Guidance for DIY Projects In general, a well-trained and experienced indoor mold remediation professional (CMR) should be consulted when performing remediation. You may find a NORMI
Mold Management Plan Operations & Maintenance
Document #: SAFETY_015 Revision Date: October 4, 2010 Mold Management Plan Operations & Maintenance Developed by: Environmental Health & Safety Approved by: Associate VP of Facilities & Campus Services
INDOOR AIR QUALITY POST-OCCUPANCY ASSESSMENT. Massachusetts Department of Revenue 100 TradeCenter, Suite 760 Woburn, MA
INDOOR AIR QUALITY POST-OCCUPANCY ASSESSMENT Massachusetts Department of Revenue 100 TradeCenter, Suite 760 Woburn, MA Prepared by: Massachusetts Department of Public Health Bureau of Environmental Health
SECTION 23 01 30.51 HVAC AIR-DISTRIBUTION SYSTEM CLEANING
SECTION 23 01 30.51 HVAC AIR-DISTRIBUTION PART 1 - GENERAL 1.1 SUMMARY A. Section includes cleaning of interior surfaces of HVAC equipment. The HVAC equipment cleaning work includes the following: 1. Air
DuPont Surfaces. Suitable for both horizontal and vertical applications, Corian solid surfaces and Zodiaq
DuPont Surfaces contributing to sustainable design and leed Durable, easy to maintain, and low-voc emitting, DuPont Corian solid surfaces and DuPont Zodiaq quartz surfaces can contribute to your sustainable
Innovation #9/12. of all Formaldehyde for up to
Innovation #9/12 of all Formaldehyde for up to Gyproc Activ Air Benefits of Activ Air Improves the indoor air quality, providing healthier interior environments Permanently reduces Formaldehyde and other
ASBESTOS SCIENCE TECHNOLOGIES, INC.
ASBESTOS SCIENCE TECHNOLOGIES, INC. P.O. Box 505 Bangor, CA 95914 Phone (530) 518-0934 Email - [email protected] Report for Lincoln Elementary School 1582 Lincoln Road Yuba City, Ca. 95993 Mold Report
INDOOR AIR QUALITY ASSESSMENT MOLD INVESTIGATION. Department Of Children and Family 810 Memorial Drive Cambridge, Massachusetts
INDOOR AIR QUALITY ASSESSMENT MOLD INVESTIGATION Department Of Children and Family 810 Memorial Drive Cambridge, Massachusetts Prepared by: Massachusetts Department of Public Health Bureau of Environmental
APPENDIX B. EPA s Investigating, Evaluating, and Remediating Moisture and Mold Problems (see EPA website for complete details)
APPENDIX B. EPA s Investigating, Evaluating, and Remediating Moisture and Mold Problems (see EPA website for complete details) Table 1: Water Damage - Cleanup and Mold Prevention Table 1 presents strategies
Building and Grounds Maintenance Checklist
Building and Grounds Maintenance Checklist Name: School: Room or Area: Date Completed: Signature: Instructions 1. Read the IAQ Backgrounder and the Background Information for this checklist. 2. Keep the
THE LEADER IN PERFORMANCE INDOOR AIR QUALITY MEASUREMENTS
THE LEADER IN PERFORMANCE INDOOR AIR QUALITY MEASUREMENTS INDOOR AIR QUALITY INSTRUMENTS UNDERSTANDING, ACCELERATED BREATHE A LITTLE EASIER WITH TSI Indoor air quality is a growing concern. With the increasing
How To Prevent And Manage A Flood And Mold
Flood Response and Mold Prevention Program Prepared by the Berea College Department of Environmental Health and Safety Revised May 2010 Contents I. Introduction II. III. IV. Flood and Mold Hazards Roles
Mold and Mildew Mold and mildew can be detected by sight, smell and touch.
Mold and Mildew Mold and mildew can be detected by sight, smell and touch. Molds are usually black (not unlike the molds that grow in showers and between grout), green or tan in color, but can be in various
Indoor Air Quality Issues for Hotels
Indoor Air Quality Issues for Hotels Chai chen Chao DEA 670 Spring, 2000 Thermal Control Relative Humidity Winter Temperature Summer Temperature 30% 68.5 F - 76.0 F 74.0 F - 80.0 F 40% 68.5 F - 75.5 F
There are several types of air cleaning devices available, each designed to remove certain types of pollutants.
Please Note: EPA neither certifies nor recommends particular brands of home air cleaning devices. While some home air cleaning devices may be useful in some circumstances, EPA makes no broad endorsement
Public Employees Occupational Safety and Health Program
Public Employees Occupational Safety and Health Program Public Employer s Guide and Model Written Program for The Indoor Air Quality Standard (N.J.A.C. 12:100-13) (2007) Fred M. Jacobs, M.D., J.D. Jon
Staff shall ensure that airflow is not obstructed by the blocking of ventilators with posters, furniture, books, or other obstacles.
1 Environmental Safety AR 3514 The Superintendent may designate and train one or more employees to oversee and coordinate the district's environmental safety program(s). The responsibilities of the coordinator(s)
School Renovation and Construction: What you Need to Know to Protect Child and Adult Environmental Health
School Renovation and Construction: What you Need to Know to Protect Child and Adult Environmental Health Healthy Schools Network, Inc. www.healthyschools.org 2000, 2012 www.cleaningforhealthyschools.org
INDOOR AIR QUALITY REASSESSMENT. Sgt. William H. Carney Memorial Academy 247 Elm Street New Bedford, Massachusetts
INDOOR AIR QUALITY REASSESSMENT Sgt. William H. Carney Memorial Academy 247 Elm Street New Bedford, Massachusetts Prepared by: Massachusetts Department of Public Health Bureau of Environmental Health Indoor
Controlling Condensation On CWP Insulation BY ED LIGHT, MEMBER ASHRAE; JAMES BAILEY, P.E., MEMBER ASHRAE; AND ROGER GAY
This article was published in ASHRAE Journal, Decemeber 2014. Copyright 2014 ASHRAE. Posted at www.ashrae.org. This article may not be copied and/or distributed electronically or in paper form without
MOLD REMEDIATION KEY STEPS
MOLD REMEDIATION KEY STEPS The EPA has developed the following guidelines for mold remediation managers. These guidelines are generally helpful, but we believe an expert in the industry should be consulted
1. Certification: Employ an ASCS certified by NADCA on a full-time basis. 2. Supervisor Qualifications: Certified as an ASCS by NADCA.
PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to this Section.
INDOOR AIR QUALITY INTRODUCTION WHAT ARE THE SYMPTOMS OF SICK BUILDING SYNDROME? WHEN DID POOR INDOOR AIR QUALITY BECOME A PROBLEM?
INDOOR AIR QUALITY Public Employees Occupational Safety and Health Program Richard J. Codey Acting Governor November, 2004 INTRODUCTION The average person sends approximately 90% of their time indoors.
MOLD REMEDIATION PROCEDURES
Page: 1 of 5 1.0 PROGRAM OBJECTIVE The purpose of this procedure is to define the responsibilities, methods, procedures and training required to safely and effectively remove or clean mold-contaminated
March 2007. Get The Mold Out: Mold Clean-Up Guidance for Residences. Introduction
March 2007 Connecticut Department of Public Health Environmental Health Section Environmental & Occupational Health Assessment Program 410 Capitol Avenue MS # 11EOH, PO Box 340308 Hartford, CT 06134-0308
Old Dominion University Mold Management Plan
OFFICE OF ENVIRONMENTAL HEALTH AND SAFETY 5255 Hampton Blvd. Spong Hall, suite 2501 Norfolk, Virginia 23529 Phone: (757) 683-4495 Fax: (757) 683-6025 Occupational Safety & Health Environmental Health Laboratory
Guidelines for Mold Remediation (Removal)
Guidelines for Mold Remediation (Removal) Indoor mold growth, water damage, or musty odors should be addressed quickly. Removing mold growth and correcting the underlying cause of water accumulation can
FEDERAL LEADERSHIP IN HIGH PERFORMANCE and SUSTAINABLE BUILDINGS MEMORANDUM OF UNDERSTANDING
FEDERAL LEADERSHIP IN HIGH PERFORMANCE and SUSTAINABLE BUILDINGS MEMORANDUM OF UNDERSTANDING PURPOSE: With this Memorandum of Understanding (MOU), signatory agencies commit to federal leadership in the
Restoring your Property: How to be prepared for Rapid Response to Flood Damage
Restoring your Property: How to be prepared for Rapid Response to Flood Damage After a flood, the restoration process can be long and complex, particularly for large commercial properties. Failure to apply
IEQ-15 Air Distribution System
AIM OF CREDIT To encourage and recognise the design and maintenance of air distribution systems that minimise the risk of particulate and microbial contamination to the internal air supply. CREDIT CRITERIA
ASBESTOS MANAGEMENT PROGRAM
ASBESTOS MANAGEMENT PROGRAM September 2015 Asbestos Management Program Table of Contents I. Purpose II. III. IV. Definitions Identification of Asbestos Asbestos Sampling V. Notification and Labeling VI.
DESERT RESEARCH INSTITUTE MOLD ASSESSMENT AND REMEDIATEION PROCEDURE
1.0 Introduction DESERT RESEARCH INSTITUTE This Desert Research Institute (DRI) Mold Assessment and Remediation Procedure was established to assure that consistent and uniform information is provided to
BUILDING ASSESSMENT QUESTIONNAIRE. B. TENANTS Is there more than one tenant in the building? YES
Department of Health and Human Services, Division of Public Health Occupational and Environmental Epidemiology Branch 1912 Mail Service Center, Raleigh, North Carolina 27699-1912 BUILDING ASSESSMENT QUESTIONNAIRE
Why Measure Carbon Dioxide Inside Buildings? By Rich Prill, Washington State University Extension Energy Program
Why Measure Carbon Dioxide Inside Buildings? By Rich Prill, Indoor air quality Workers and students spend about half their waking hours at work or school. Therefore, maintaining adequate indoor air quality
THE APPLICATION OF OZONE FOR AIR TREATMENT: CASE STUDY OF A BINGO HALL HVAC SYSTEM
1 Application Note AT-102 THE APPLICATION OF OZONE FOR AIR TREATMENT: CASE STUDY OF A BINGO HALL HVAC SYSTEM Lawrence B. Kilham 1 and Randall M. Dodd 2 1 Eco Sensors, Inc. Santa Fe, New Mexico, USA [email protected]
North Carolina State University. Asbestos Management Plan
North Carolina State University 1.0 Introduction Purpose The purpose of this plan is to establish the polices and procedures to be used at North Carolina State University (NCSU) in the management of building
Material Safety Data Sheet
Company Department Address Material Safety Data Sheet COMPANY IDENTIFICATION LANXESS Corporation Product Safety & Regulatory Affairs 111 RIDC Park West Drive Pittsburgh, PA 15275-1112 USA TRANSPORTATION
Lead Exposure Management Plan
Lead Exposure Management Plan 1.0. Policy CSUF has developed the Lead Exposure Management Plan to reduce occupational and environmental exposure to lead, a potent neurotoxin and carcinogen that causes
Fans That Sense & Extract Volatile Organic Compounds and Humidity
Premium Choice Ventilation Fans Featuring Fans That Sense & Extract Volatile Organic Compounds and Humidity Indoor Air Quality Concerns Today s homes are built to be tighter and more energy efficient than
University of Vermont
University of Vermont Department of Physical Plant Burlington, Vermont WATER INTRUSION GUIDELINES In accordance with: IIRC S500 IIRC S520 EPA Document 402-K-01-001 REVISED AND DISTRIBUTED BY: THE UNIVERSITY
MOLD ASSESSMENT. Charles A. Bernazzani Elementary School 701 Furnace Brook Parkway Quincy, Massachusetts
MOLD ASSESSMENT Charles A. Bernazzani Elementary School 701 Furnace Brook Parkway Quincy, Massachusetts Prepared by: Massachusetts Department of Public Health Bureau of Environmental Health Indoor Air
Questions & Answers (Q & A) Regarding Asbestos Treatment with the Fire Suppression and Renovation Project
Questions & Answers (Q & A) Regarding Asbestos Treatment with the Fire Suppression and Renovation Project The Watergate Community is currently in the process with the fire suppression and interior renovations
Risk Bulletin. Mold Prevention and Control for Mechanical and HVAC Contractors. XL Group Insurance
XL Group Insurance Risk Bulletin Mold Prevention and Control for Mechanical and HVAC Contractors Mechanical contractors have an inherent risk of mold claims arising out of the heating, ventilation, and
Fungal Assessment. Smith Recreation Community Centre 1019 Hwy 2A, Smith, Alberta
Top Q A DIVISION OF TOP QUALITY INSPECTIONS INC. Fungal Assessment Smith Recreation Community Centre 1019 Hwy 2A, Smith, Alberta 2012 P. O. B o x 8 3 0 2 4, E d m o n t o n, A B T 5 T 6 S 1 P h o n e :
34% 81% 84% 19% GOLD PROJECT HIGHLIGHTS. LEED Facts. Stubbs Laboratory
HARVARD UNIVERSITY FACULTY OF ARTS AND SCIENCES LEED-CI V3.0 STUBBS LABORATORY GORDON MCKAY LABS BUILDING Gordon McKay Building, 9 Oxford Street, Cambridge, MA 02138 GOLD The Stubbs Laboratory is a 2,035
Get The Mold Out: Mold Clean-Up Guidance for Residences. Introduction
Connec cut Department of Public Health Environmental & Occupa onal Health Assessment Program Environmental Health Sec on 410 Capitol Avenue, MS # 11EOH, PO Box 340308 Har ord, CT 06134-0308 Telephone:
POMONA COLLEGE Sustainability Integration Office Facilities and Campus Services
POMONA COLLEGE Sustainability Integration Office Facilities and Campus Services May 200 Table of Contents NEW CONSTRUCTION/MAJOR RENOVATION Process... Design... 3 MINOR RENOVATIONS/PROJECTS Process...
MOISTURE MANAGEMENT DURING THE CONSTRUCTION PROCESS
MOISTURE MANAGEMENT DURING THE CONSTRUCTION PROCESS Ed Light 1,*, James Bailey 1, and Roger Gay 1 1 Building Dynamics, LLC, Ashton, MD (USA) *Corresponding email: [email protected] Published
07 21 19 Guide Specification STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM
07 21 19 STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM 7819 Broadview Road Cleveland, OH 44131 800-522-4522 February, 2011 SPEC NOTE: This guide specification is intended for use when specifying
HVAC Systems and Indoor Air Quality. Douglas K. Spratt, M.Sc., P.Eng.
HVAC Systems and Indoor Air Quality Douglas K. Spratt, M.Sc., P.Eng. The 5 Senses Architecture Electrical Structural Mechanical Hearing Seeing Smelling Feeling Tasting HVAC Systems are Dynamic Heat Gains
Mold Basics. Why is mold growing in my home?
Mold Basics The key to mold control is moisture control. If mold is a problem in your home, you should clean up the mold promptly and fix the water problem. It is important to dry water-damaged areas and
SECTION 08 41 1 ALUMINUM FRAMED ENTRANCES and STOREFRONTS. System 402 Flush-Glazed Screw Spline Storefront
PART 1 GENERAL 1.01 Work Included SECTION 08 41 1 ALUMINUM FRAMED ENTRANCES and STOREFRONTS System 402 Flush-Glazed Screw Spline Storefront A. Furnish and install aluminum architectural storefront system
Guide to the (Non-Residential) California Green Building Standards Code. Including changes effective July 1, 2012
Guide to the (Non-Residential) California Green Building Standards Code An educational publication by the California Building Standards Commission Third Edition January 2012 CALGreen Section: 5.710.6.2
STANDARD OPERATING PROCEDURES FOR MOLD REMEDIATION
West Virginia University Environmental Health and Safety STANDARD OPERATING PROCEDURES FOR MOLD REMEDIATION Origination Date August 2013. Contents Purpose:... 2 Job Scope... 2 Definitions... 2 Roles/Responsibilities:...
Mould Mould A Basic Guide
Mould A Basic Guide Summary Mould is a fact of life. Moulds will grow practically everywhere people live and work. Mould is recognized as an occupational hazard for indoor workers as well as outdoor workers
University of Nevada, Reno Facilities Services Department STANDARD OPERATING PROCEDURE. Facilities Maintenance Services
University of Nevada, Reno Facilities Services Department STANDARD OPERATING PROCEDURE Facilities Maintenance Services Indoor Flood Cleanup and Mold Prevention DATE: 6/24/15 REVISED: PURPOSE This University
SMACNA s IAQ for Occupied Buildings Under Construction
16 th Annual Technical Conference Rocky Mountain Section AIHA/ASSE September 29. 2010 SMACNA s IAQ for Occupied Buildings Under Construction Bill Mele Indoor Environmental Solutions, Inc. 303-948-0500,
Mold. Guidelines for New Jersey Residents. Understanding Mold Investigations & Remediation
Mold Guidelines for New Jersey Residents Understanding Mold Investigations & Remediation What Services Should I Ask For? What Are Important Inspection Procedures? Is Mold Sampling Helpful? What Information
CENTER FOR ENVIRONMENTAL HEALTH Emergency Response/Indoor Air Quality Program
CENTER FOR ENVIRONMENTAL HEALTH Emergency Response/Indoor Air Quality Program Guidance Concerning Remediation and Prevention of Mold Growth and Water Damage in Public Schools/Buildings to Maintain Air
Asbestos Inspection Project Procedure
EOSMS 402 Date: 01/13/2014 Page 1 of 6 1) Purpose This document is intended to specify the scope of services required of Asbestos Contractor in asbestos inspection projects at Kennesaw State University
Asbestos in the Workplace: A Guide to Removal of Friable Asbestos Containing Material
Asbestos in the Workplace: A Guide to Removal of Friable Asbestos Containing Material Revised November 21, 2013 Application Code of Practice Where asbestos is present or believed to be present in a workplace
INDOOR AIR QUALITY ASSESSMENT. Dennett Elementary School 80 Crescent Street Plympton, Massachusetts
INDOOR AIR QUALITY ASSESSMENT Dennett Elementary School 80 Crescent Street Plympton, Massachusetts Prepared by: Massachusetts Department of Public Health Bureau of Environmental Health Assessment Emergency
Exposure and Control of Ten High Priority MSHA Contaminants in Metal Mines. Presented by: Shannon E. Newton, MPH, CIH
Exposure and Control of Ten High Priority MSHA Contaminants in Metal Mines Presented by: Shannon E. Newton, MPH, CIH Topics What are these hazards? How can they harm you? Why do we care? How do we tell
Water should be removed as soon as possible once the safety of the structure has been verified.
FACT SHEET Posted October 18 2005 Check List for Infection Control Concerns when Reopening Healthcare Facilities Closed due to Extensive Water and Wind Damage Prior to opening a healthcare facility that
BUREAU OF ENVIRONMENTAL HEALTH Emergency Response/Indoor Air Quality Program
BUREAU OF ENVIRONMENTAL HEALTH Emergency Response/Indoor Air Quality Program Use of Moisture Measuring Devices in Evaluating Water Damage in Buildings July 2007 The evaluation of mold colonization of building
What is LEED? Why pursue LEED accreditation? How does LEED accomplish these goals? Sustainable sites Water efficiency Energy and Atmosphere
Green AAON for What is LEED? Sustainability and green have recently become terms used within the building industry (and others) to refer to a construction project that has low environmental impact, or
RULE 1102. DRY CLEANERS USING SOLVENT OTHER THAN PERCHLOROETHYLENE
(Adopted January 6, 1978)(Amended August 3, 1979)(Amended July 11, 1980) (Amended August 3, 1990)(Amended December 7, 1990) (Amended November 17, 2000) RULE 1102. DRY CLEANERS USING SOLVENT OTHER THAN
Indoor Air Quality- What You Need to Know
Indoor Air Quality- What You Need to Know Overview Indoor air quality (IAQ) concerns present ever-mounting problems to facility managers and health and safety personnel. From toxic mold to carbon dioxide
Now that Your Building Experienced Water Damage What Must You and Your Water Damage Restoration Contractor Agree On?
w that Your Building Experienced Water Damage What Must You and Your Water Damage Restoration Contractor Agree On? By Completing a Building and Occupant Survey Hopefully Your Questions will be Answered
How To Test For Residual Dust
Experience on Measurement of Residual Dust as Quality Assurance Documentation During Mold Remediation AIHCE - Chicago, Illinois May 16, 2006 P. Morey & G. Crawford Boelter & Yates, Inc. Gettysburg, PA
Indoor Environmental Quality Management Plan
RILLION PUBLIC SCHOOL BOARD OF EDUCATION SERIES 700: SUPPORT SERVICES FILE: 737 Indoor Air Quality Management Brillion Public Schools Indoor Environmental Quality Management Plan 1. Mission Statement School
Why is my air conditioner dripping on my customers?
De-Mystifying HVAC Why is my air conditioner dripping on my customers? By Ron Prager One of the most frequent emergency service requests is a call for an air conditioner leaking water into the store. These
Carson Dorn, Inc. December 18, 2012. Patrick Holmes Associate Manager Juneau I, LLC 645 G Street, Suite 100-604 Anchorage, AK 99501. Dear Mr.
Carson Dorn, Inc. 712 West 12th Street Juneau, Alaska 9981 December 18, 212 Patrick Holmes Associate Manager Juneau I, LLC 645 G Street, Suite 1-64 Anchorage, AK 9951 Dear Mr. Holmes, The renovation of
Draft Healthy Home Environmental Assessment Principles
IAQA Home Health Committee Draft Healthy Home Environmental Assessment Principles Scope: This document provides the essential principles and concepts to conduct a healthy home environmental assessment.
ASBESTOS IN ROOFING SYSTEMS WORK PRACTICES AND DISPOSAL IN ASSOCIATION WITH ROOFING PROJECTS
ASBESTOS IN ROOFING SYSTEMS WORK PRACTICES AND DISPOSAL IN ASSOCIATION WITH ROOFING PROJECTS 1.0 GENERAL 1.1 SUMMARY A. The following procedures apply to the project manual and drawings for asbestos in
PEOSH. Indoor Air Quality Training for Asthma-Friendly Schools Part I PEOSH Indoor Air Quality Standard Overview. Eric Weren, MSIH
PEOSH Indoor Air Quality Training for Asthma-Friendly Schools Part I PEOSH Indoor Air Quality Standard Overview Eric Weren, MSIH Public Employees Occupational Safety and Health Unit IAQ Asthma-Friendly