Prepared for Dorman Long Engineering Technology Consultant (Shanghai) Co., Ltd.



Similar documents
Test Report. Prepared for: Technologic Systems, Inc. Model: TS-8820

Rated Power(W) 8W 2. EG-LED W 3. EG-LED W

TEST REPORT EN (1997) +A1 (2001)

SHENZHEN GEMBIRD ELECTRONICS LTD EMC REPORT

EN v1.2.1 TEST REPORT FOR ag/Draft n WLAN PCI-E Mini Card MODEL NUMBER: BCM94322MC REPORT NUMBER: 07U

Test Report #: Date: April 8, 2005

Declaration of Conformity.

FCC PART 15B CLASS A MEASUREMENT AND TEST REPORT

EMC TEST REPORT For. Webcam. Model Number: CAM67U

Declaration of Conformity.

Declaration of Conformity.

Declaration of Conformity.

Standard: EN :1995, EN :1996, ENV :1993, & EN :1995 Solid State Energy Meter

SGS-CSTC Standards Technical Services (Shanghai) Co., Ltd.

EMC TEST REPORT For. Shenzhen Homelux Security Equipment Co., Ltd. Auto Dialer. Model No.: HX-GD20

Declaration of Conformity.

TEST REPORT Rapporto di prova EMC N Test facility site: via L. da Vinci, 92, Caravaggio (BG), Italy Sede laboratorio

Measurement of RF Emissions from a Final Coat Electronics Corrosion Module

Declaration of Conformity.

Electromagnetic Compatibility Test Report Test results of Floww equipment

EMC Test for Compliance with EU EMC Directive 2004/108/EU

Variant Model No. The equipment under test has found to be compliant with the applied standards. (Refer to the attached test result for more detail.

MYRICOM, INC. TEST REPORT FOR THE LAN INTERFACE CARD, M3F2-PCIXE-2

EMC TEST REPORT. Page: 1 of 38. Reference No.: WT S-E

CERTIFICATE. Issued Date:May. 18, 2006 Report No.: 065L043-IT-CE-P07V03. MGate MB318n(-T) (n=0~9,a~z)

TEST REPORT. CONCLUSION: The submitted sample was found to COMPLY with the test requirement

Electromagnetic Compatibility Test Report. DC DC umodule Regulator LTM4613

MYRICOM, INC. TEST REPORT FOR THE SERVER RACK, 10G-PCIE2-8B2-2S & 10G-PCIE2-8B2-2QP FCC PART 15 SUBPART B SECTIONS AND CLASS A TESTING

CE-EMC TEST- REPORT TEST REPORT NUMBER: EFSN E-E01 EUROFINS TESTING TECHNOLOGY (SHENZHEN) CO., LTD.

TEST REPORT. Please refer to section 3 of this report which indicates which item was actually tested and which were electrically identical.

EMC STANDARDS STANDARDS AND STANDARD MAKING BODIES. International. International Electrotechnical Commission (IEC)

BioStation Mifare OC(BSM-OC) NONE. Receipt Date 21-Feb-08 Receipt Number. Issued Date 18-Mar-08 Tested Date

FCC PART 15 SUBPART C EMI MEASUREMENT AND TEST REPORT

AN Surging Ideas TVS Diode Application Note PROTECTION PRODUCTS. TRANSIENT IMMUNITY STANDARDS: IEC x

RAPPORTO DI PROVA / TEST REPORT

IEC ESD Immunity and Transient Current Capability for the SP72X Series Protection Arrays

Report No R-RFCEP02V01. Test Report. MS-6633, VS12489, NetOn AP1900. Transmitter Module. MSI / MS-6894

Clamp Filters that Suppress Emission Noise Provide Immunity Against Surge Noise

ELECTROMAGNETIC COMPATIBILITY TEST. Report reference N R-255 EMC 2010

Telephone- and leased line modem for industrial applications TD-36

LAB 1 TECHNICAL DOC 3 IN ONE LAB DEVICE. Velleman Legen Heirweg Gavere Belgium

40 Years of experience in EMC testing

Declaration of Conformity.

STRATO LED Drivers 70W, Single output

Waveguide Access Point WGA631. Product Guide

Jens-EMC ApS. Randersvej 6 DK-8600 Silkeborg Denmark. EMC test report SeaCom. AC48/SeaCom1000 & AC128/SeaCom2100

Cond-IS RF Conducted Immunity System

CE EMC Test Report. : Texas Instruments Incorporated : WiFi and Bluetooth Evaluation Board

UNDERSTANDING AND CONTROLLING COMMON-MODE EMISSIONS IN HIGH-POWER ELECTRONICS

Report No R-RFCEP76V01-A. Test Report. Model No. MS-AE12, AE2420 3D, MS-AE31 3D, MS-AE31, AE2420. Date of Receipt June 15, 2010

Teseq ESD Simulator Verification

Applications in EMC testing. Outline. Antennas for EMC Testing. Terminology

Dual Chamber Temporary External Pacemaker

30 In Compliance October

NMI M 6-2 Electricity Meters. Part 2: Test Report Format

RADIO TEST REPORT. EN SRD radio equipment to be used in the 1 GHz to 40 GHz frequency range. DAkkS - Registration number : D-PL

Rules for Classification and Construction Additional Rules and Guidelines

Rack mounted telephone- and leased line modem for industrial applications

Report No R-RFCEP76V01. Test Report. Product Name All in one PC Model No. MS-6657,AE2220 Transmitter Module Realtek / RTL8191SE

Foxboro Evo Process Automation System

AN003. Evaluation of Anechoic Chambers For EMC Measurements Using A CNE. Overview. CNE III 9kHz to 2GHz Conducted and radiated output

DATA SHEET DVI - HDCP Extension Cable

PESDxU1UT series. 1. Product profile. Ultra low capacitance ESD protection diode in SOT23 package. 1.1 General description. 1.

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 1

Predicting radiated emissions from cables in the RE02/RE102/DO- 160/SAE J test set up, using measured current in NEC and simple TX equations.

DDX 7000 & Digital Partial Discharge Detectors FEATURES APPLICATIONS

AN3353 Application note

RoHS APPROVAL SHEET. ituner 12V/6.6A SERIES NO. (E17) EA10953A. ( ) Edac Power Electronics (Suzhou) Co., Ltd. 59 No.59, Chang Sheng Road, Sheng Pu,

DDX 7000 & Digital Partial Discharge Detectors FEATURES APPLICATIONS

CAN bus ESD protection diode

CE MARK TECHNICAL FILE

DUAL%CHANNEL BROADBAND%LINEAR%AMPLIFIER Model&A800D

EMC Standards: Standards of good EMC engineering

Agilent N8973A, N8974A, N8975A NFA Series Noise Figure Analyzers. Data Sheet

Single-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

Current Probes. User Manual

COUPLING / DECOUPLING NETWORK (CDN) FOR UNSCREENED BALANCED PAIRS

The EMI-Receiver according to CISPR

EMC for test engineers by. Laplace Instruments Ltd. An introduction to the world of EMC compliance testing for engineers new to the topic.

1587/1577. Insulation Multimeters. Technical Data. Two powerful tools in one.

SDC15. TVS Diode Array for ESD Protection of 12V Data and Power Lines. PROTECTION PRODUCTS Description. Features. Mechanical Characteristics

Espotel Test Laboratory Services. November 20, 2014

MCR-VDC-UI-B-DC. Voltage Transducer for DC Voltages. INTERFACE Data Sheet _en_01. 1 Description

Declaration of Conformity.

Charged cable event. 1 Goal of the ongoing investigation. 2 Energy sources for the CDE. Content

Pre-Compliance Test Method for Radiated Emissions of Automotive Components Using Scattering Parameter Transfer Functions

15 Series - Electronic step relay and dimmer. Features SERIE

RClamp0821P. Ultra-Low Capacitance 1-Line ESD protection. PROTECTION PRODUCTS - RailClamp Description. Features. Mechanical Characteristics

Verizon NEBS TM Compliance: HVAC Systems NEBS Requirements Verizon Technical Purchasing Requirements VZ.TPR.9808 Issue 1, April 2014

Workbench EMC Measurements by Henry W. Ott Henry Ott Consultants

Fibre Optic Solutions for your Test and Instrumentation needs

FREQUENCY RESPONSE ANALYZERS

LIN-bus ESD protection diode

Isolated AC Sine Wave Input 3B42 / 3B43 / 3B44 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Model BiConiLog Antenna MANUAL EMC TEST SYSTEMS, L.P. MARCH 2002 REV C PN

Advancements in Lightning Test Services

Draft ETSI EN V1.2.1 ( )

CONDUCTED EMISSION MEASUREMENT OF A CELL PHONE PROCESSOR MODULE

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

Transcription:

www.ecmg-global.com EMC TEST REPORT On Model Name: DL-P40 Computer Control System Model Number: Release 3.0 Hardware and Software Brand Name: Dorman Long Technology Ltd. Trade Mark: DLT Prepared for Dorman Long Engineering Technology Consultant (Shanghai) Co., Ltd. According to EN 61326-1: 2006 Electrical equipment for measurement, control and laboratory use - EMC requirements Part 1: General requirements (IEC 61326-1: 2005) Test Report #: Prepared by: Reviewed by: QC Manager: DOR-0907-8294-CE Chris Huang Harry Zhao Paul Chen Test Report Released By: 2009, August 4 Paul Chen Date

Test Location Tests performed in a Certified ANSI Semi-Anechoic Chamber and Shielded Room performed testing. Test Site Location #1: ECMG Worldwide Certification Solution, Inc. (China) Building 2, 1298 Lian Xi Road, Pu Dong New Area, Shanghai, P.R. China 201204 Tel: 86-21-51909300 Fax: 86-21-51909333 FCC Registration Number: 172634 Test Site Location#2: Shanghai Institute of Quality Inspection and Technicl Research No.627, Yongjia Road, Shanghai, PRC. Tel: 86-21-62335275 Fax: 86-21-64317195 CNAS Certificate Number: L0128 Accreditation Bodies The report is prepared by ECMG Worldwide Certification Solution, Inc., which is a fully accredited Test Laboratory for ITE, ISM, MIL-STD and Telecommunications Products.

Table of Contents DISCLAIMER NOTICE 1 REPRODUCTION CLAUSE 1 ADMINISTRATIVE DATA 2 EUT DESCRIPTION 2 TEST SUMMARY 3 PERFORMANCE CRITERIA 5 TEST MODE JUSTIFICATION 6 EUT EXERCISE SOFTWARE 6 EQUIPMENT MODIFICATION 6 EUT SAMPLE PHOTOS - RELEASE 3.0 HARDWARE AND SOFTWARE 7 TEST SYSTEM DETAILS 12 CONFIGURATION OF TESTED SYSTEM 13 ATTACHMENT 1 - CONDUCTED EMISSION TEST RESULTS 14 ATTACHMENT 2 - RADIATED EMISSION TEST RESULTS 19 ATTACHMENT 3 - ESD IMMUNITY TEST 23 ATTACHMENT 4 - RADIATED SUSCEPTIBILITY IMMUNITY TEST 29 ATTACHMENT 5- EFT IMMUNITY TEST 32 ATTACHMENT 6 - SURGE IMMUNITY TEST 35 ATTACHMENT 7 - CONDUCTED IMMUNITY TEST 38 ATTACHMENT 8 - POWER FREQUENCY MAGNETIC FIELD IMMUNITY TEST 41-43

Disclaimer Notice When government drawing, specification, or other data are used for any purpose other than in connection with a definitely related government procurement operation, the United States Government thereby incurs no responsibility nor any obligation whatsoever; and the fact that the Government may have formulated, furnished, or in any way supplied the said drawing, specifications, or other data, is not to be regarded by implication or otherwise in any manner licensing the holder or any other person or corporation, or conveying any rights or permission to manufacture, use, or sell patented invention that may in any way be related thereto. This report must not be used to claim product endorsement by any agency of the U.S. Government. Reproduction Clause Any reproduction of this document must be done in full. No single part of this document may be reproduced without permission from ECMG Worldwide Certification Solution, Inc., 684 West Maude Avenue Sunnyvale, CA 94085. Prepared by ECMG Worldwide Certification Solution, Inc. Page 1 of 43

Administrative Data Test Sample Model Number Brand Name Trade Mark Serial Number Date Tested Applicant : DL-P40 Computer Control System : Release 3.0 Hardware and Software : Dorman Long Technology Ltd. : DLT : Engineering Sample : 2009, July 27 th and 28 th : Dorman Long Engineering Technology Consultant (Shanghai) Co., Ltd. 19D, Yujia Building, 1336 Huashan Road, 200052, P.R.China Telephone : 86-21-62110500 Fax : 86-21-62110523 Manufacturer : Dorman Long Engineering Technology Consultant (Shanghai) Co., Ltd. 19D, Yujia Building, 1336 Huashan Road 200052, P.R.China EUT Description Dorman Long Engineering Technology Consultant (Shanghai) Co., Ltd. model tested Release 3.0 Hardware and Software (referred to as the EUT in this report) is a Heavy Lift Controller. The control unit contains 1 power pack node and 1~2 jack node and connected by CAN B. The control units are connected by CAN A. Prepared by ECMG Worldwide Certification Solution, Inc. Page 2 of 43

Test Summary The Electromagnetic Compatibility requirements on model Release 3.0 Hardware and Software for this test are stated below. All results listed in this report relate exclusively to this above-mentioned model as the Equipment under Test. This report confers no approval or endorsement upon any other component, host or subsystem used in the test set-up. Emission Tests Specifications Description Test Results Test Point Remark CISPR 11: Edition 4.1:2006, Group 1, Class B Conducted Emission Passed by 13.51 db of QP Passed by 8.60 db of AVE DC Input Port Attachment 1 CISPR 11: Edition 4.1:2006, Group 1, Class B Radiated Emission Passed by 8.45 db of QP Enclosure Attachment 2 IEC 61000-3-2 Edition 3.0: 2005 Power Harmonics Emission The EUT is DC Powered, test is not applicable IEC 61000-3-3, Edition 1.1: 2002 Continue on to next page Voltage Fluctuation/Flick er Prepared by ECMG Worldwide Certification Solution, Inc. Page 3 of 43

Immunity Test Requirements for equipment intended for use in industrial locations Specifications Description Test Results Test Point Remark IEC 61000-4-2, Edition 2.0 (2008) Electrostatic Discharge Passed Level 3, Air Passed Level 2, Contact Air 8kV / Contact 4kV Enclosure Meets Performance Criteria B Attachment 3 IEC 61000-4-3: Edition 3.1 (2008) RF Immunity Passed Level 2 10V/m (80MHz-1000MHz), 3V/m (1.4GHz-2GHz), 1V/m(2.0GHz-2.7GHz) Enclosure Meets Performance Criteria A Attachment 4 IEC 61000-4-4: Edition 2.0 (2007) EFT/Bursts Immunity Passed Level 3 DC Power line: 2kV I/O Line: 1kV DC Input Port I/O Port Meets Performance Criteria B Attachment 5 IEC 61000-4-5: Edition 2.0 (2005) Surge Immunity Passed Level 2, Differential mode DC Power Line: Line - Line 1kV Passed Level 3, Common mode DC Power Line: Line - Ground 2kV DC Input Port I/O Port Meets Performance Criteria B Attachment 6 Passed Level 2, Common mode I/O Line: Line Ground 1kV IEC 61000-4-6: Edition 3.0 (2008) Conducted Immunity Passed Level 2 DC Power Line: 3V 0.15MHz-80MHz I/O Line: 3V 0.15MHz-80MHz DC Input Port I/O Port Meets Performance Criteria A Attachment 7 IEC 61000-4-8: Edition 1.1 (2001) IEC 61000-4-11: Edition 2.0 (2004) Power Frequency Magnetic Field Immunity Voltage Dips & Short Interruption 30A/m Enclosure Meets Performance Criteria A Attachment 8 The EUT is DC Powered, test is not applicable Prepared by ECMG Worldwide Certification Solution, Inc. Page 4 of 43

Performance Criteria As described in EN61326-1: 2006 Performance Criteria A: The apparatus shall continue to operate as intended during and after the test. No degradation of performance or loss of function is allowed below a performance level specified by the manufacturer, when the apparatus is used as intended. The performance level may be replaced by a permissible loss of performance. If the minimum performance level of the permissible performance loss is not specified by the manufacturer, either of these may be derived from the product description and documentation and what the user may reasonably expect from the apparatus if used as intended. Performance Criteria B: The apparatus shall continue to operate as intended after the test. No degradation of performance or loss of function is allowed below a performance level specified by the manufacturer, when the apparatus is used as intended. The performance level may be replaced by a permissible loss of performance. During the test, degradation of performance is however allowed. No change of actual operating state or stored data is allowed. If the minimum performance level of the permissible performance loss is not specified by the manufacturer, either of these may be derived from the product description and documentation and what the user may reasonably expect from the apparatus if used as intended. Performance Criteria C: Temporary loss of function is allowed, provided the function the function is self-recoverable or can be restored by the operation of controls. Prepared by ECMG Worldwide Certification Solution, Inc. Page 5 of 43

Test Mode Justification The EUT is powered by 24V power or 24V DC battery. The EUT runs in communicating mode during the test. EUT Exercise Software The EUT run the software that is named by Release 3.0 Hardware and Software during the test. Equipment Modification Any modifications installed previous to testing by Dorman Long Engineering Technology Consultant (Shanghai) Co., Ltd. will be incorporated in each production model sold or leased in Europe. There were no modifications installed by ECMG Worldwide Certification Solution, Inc. (China) test personnel. Prepared by ECMG Worldwide Certification Solution, Inc. Page 6 of 43

EUT Sample Photos - Release 3.0 Hardware and Software For Power Pack Node Front view Back View Prepared by ECMG Worldwide Certification Solution, Inc. Page 7 of 43

Main Board Front View Main Board Rear View Prepared by ECMG Worldwide Certification Solution, Inc. Page 8 of 43

For Jack Node Front view Back View Prepared by ECMG Worldwide Certification Solution, Inc. Page 9 of 43

Main Board Front View Main Board Rear View Prepared by ECMG Worldwide Certification Solution, Inc. Page 10 of 43

CAN A Signal Line View CAN B Signal Line View Prepared by ECMG Worldwide Certification Solution, Inc. Page 11 of 43

Test System Details EUT Model Number: Trade Mark: Input Voltage: Serial Number: Description: Manufacturer: Release 3.0 Hardware and Software Dorman Long Technology Ltd. DC 24V Engineering Sample DL-P40 Computer Control System Dorman Long Engineering Technology Consultant (Shanghai) Co., Ltd. EUT Power Supply Model : S-100-24 Input Voltage : 200~240V AC 0.8A Output Voltage : DC 24V 4.5A Manufacturer : Meanwell Support Equipment Description Model Number Serial Number Manufacturer Power Cable Description (Meters) Notebook LATITUDE D630 8K8GB2X DELL 1.8m USB to CAN Converter USB-to-CAN compact 1.01.0087.1020 0 IXXAT N/A Cable Description Name From To Length Shielded (Y/N) Ferrite Loaded (Y/N) CAN A PP Node PC 30m Y Y (*5) CAN B PP Node Jack Node 30m Y N Prepared by ECMG Worldwide Certification Solution, Inc. Page 12 of 43

Configuration of Tested System Prepared by ECMG Worldwide Certification Solution, Inc. Page 13 of 43

ATTACHMENT 1 - CONDUCTED EMISSION TEST RESULTS CLIENT: Dorman Long Engineering Technology Consultant (Shanghai) Co., Ltd. TEST STANDARD: EN 61326-1: 2006 MODEL NUMBER: Release 3.0 Hardware and Software PRODUCT: DL-P40 Computer Control System SERIAL NO.: Engineering Sample EUT DESIGNATION: Control Equipment TEMPERATURE: 22 C HUMIDITY: 56%RH ATM PRESSURE: 101.1 kpa GROUNDING: Grounding TESTED BY: Edison Li DATE OF TEST: 2009, July 27 TEST REFERENCE: TEST PROCEDURE: TESTED RANGE: TEST VOLTAGE: RESULTS: CISPR 11 Edition 4.1:2006 Group 1 Class A The EUT is set up according to the guideline of CISPR 11 Edition 4.1:2006 for conducted emissions. The measurement is using a LISN line on each line and an EMI receiver peak scan is made at the frequency measurement range. The three highest significant peaks are then marked, and these signals are then quasipeaked and averaged. The frequency range investigated is from 150kHz to 30MHz. 150kHz to 30MHz 24V DC The EUT meets the requirements of test reference for Conducted Emissions on line L by 13.51 db of Quasi-Peak detector and by 8.60 db of Average Detector. The test results relate only to the equipment under test provided by client. CHANGES OR MODIFICATIONS: There were no modifications installed by ECMG Worldwide Certification Solution, Inc. (China) test personnel. M. UNCERTAINTY: Freq. ± 2x10-7 x Center Freq., Amp ± 2.6 db Prepared by ECMG Worldwide Certification Solution, Inc. Page 14 of 43

Line L Conducted Emission Graph Line N Conducted Emission Graph Prepared by ECMG Worldwide Certification Solution, Inc. Page 15 of 43

Line L (Hot Lead) Signal Frequency (MHz) Corrected QP Level (dbuv) Limits QP (dbuv) Margin QP (db) Frequency (MHz) Corrected AVE Level (dbuv) Limits AVE (dbuv) Margin AVE (db) 1 0.1694 57.88 79.00-21.12 0.1694 43.42 66.00-22.58 2 0.2336 59.71 79.00-19.29 0.2336 53.65 66.00-12.35 3 0.4160 64.89 79.00-14.11 0.4160 57.40 66.00-8.60 4 0.5109 59.35 73.00-13.65 0.5109 38.05 60.00-21.95 5 0.5417 59.49 73.00-13.51 0.5417 48.88 60.00-11.12 6 0.9911 53.96 73.00-19.04 0.9911 50.92 60.00-9.08 Line N (Hot Lead) Signal Frequency (MHz) Corrected QP Level (dbuv) Limits QP (dbuv) Margin QP (db) Frequency (MHz) Corrected AVE Level (dbuv) Limits AVE (dbuv) Margin AVE (db) 1 0.2357 55.33 79.00-23.67 0.2357 49.17 66.00-16.83 2 0.5500 50.93 73.00-22.07 0.5500 41.02 60.00-18.98 3 0.5645 55.46 73.00-17.54 0.5645 29.56 60.00-30.44 4 0.9910 51.91 73.00-21.09 0.9910 49.05 60.00-10.95 5 3.5560 39.39 73.00-33.61 3.5560 26.60 60.00-33.40 6 11.6800 36.26 73.00-36.74 11.6800 32.91 60.00-27.09 Prepared by ECMG Worldwide Certification Solution, Inc. Page 16 of 43

Test Equipment Manufacturer Model No. Serial No. Last Cal. Cal. Due EMI Receiver HP 85462A 3704A00349 11/29/07 11/28/09 AMN R&S ESH3-Z5 844249/018 12/04/07 12/03/09 Note: All testing were performed using internationally recognized standards. All test instruments were calibrated. SIGNED BY: ENGINEER REVIEWED BY: SENIOR ENGINEER Prepared by ECMG Worldwide Certification Solution, Inc. Page 17 of 43

EUT Model: Release 3.0 Hardware and Software Conducted Emission Test Set-up Front View Conducted Emission Test Set-up Side View Prepared by ECMG Worldwide Certification Solution, Inc. Page 18 of 43

ATTACHMENT 2 - RADIATED EMISSION TEST RESULTS CLIENT: Dorman Long Engineering Technology Consultant (Shanghai) Co., Ltd. TEST STANDARD: EN 61326-1: 2006 MODEL NUMBER: Release 3.0 Hardware and Software PRODUCT: DL-P40 Computer Control System SERIAL NO.: Engineering Sample EUT DESIGNATION: Control Equipment TEMPERATURE: 22 C HUMIDITY: 56%RH ATM PRESSURE: 101.1 kpa GROUNDING: Grounding TESTED BY: Edison Li DATE OF TEST: 2009, July 27 TEST REFERENCE: TEST PROCEDURE: CISPR 11 Edition 4.1:2006 Group 1 Class A The EUT is set up according to the guidelines of CISPR 11 Edition 4.1:2006 for radiated emissions. An EMI receiver peak scan is made at the frequency measurement range (pre-scan) in an Anechoic chamber. Signal discrimination is then performed and the significant quasi-peaked is then measured. The frequency investigated is from 30MHz to 1GHz. The following data lists the significant emission frequencies, measured levels, correction factors (including cable and antenna correction factors), and the corrected readings against the limits. Explanation of the Correction Factor is given as follows: FS= RA + AF + CF - AG Where: FS = Field Strength RA = Receiver Amplitude AF = Antenna Factor CF = Cable Attenuation Factor AG = Amplifier Gain TESTED RANGE: TEST VOLTAGE: RESULTS: 30MHz to 1,000MHz 24V DC The EUT meets the unrestricted distribution requirements of test reference for Radiated Emissions on vertical polarization by 8.45 db at 34.6500 MHz The test results relate only to the equipment under test provided by client. CHANGES OR MODIFICATIONS: There were some modifications installed by ECMG Worldwide Certification Solution, Inc. (China) test personnel. M. UNCERTAINTY: Freq. ± 2x10-7 x Center Freq., Amp ± 2.6 db Prepared by ECMG Worldwide Certification Solution, Inc. Page 19 of 43

Horizontal Radiated Emission Plot (Peak, Max Hold Mode) Vertical Radiated Emission Plot (Peak, Max Hold Mode) Prepared by ECMG Worldwide Certification Solution, Inc. Page 20 of 43

Horizontal Signal Frequency (MHz) Corrected Factor (db) Corrected QP Level db(uv/m) 3 Meter Limits db(uv/m) Margin (db) Angle of Turner (degree) Height of Tower (cm) 1 34.8500 16.89 33.59 50.00-16.41 105 105 2 396.1750 17.61 30.74 57.00-26.26 175 148 3 886.0250 24.96 35.71 57.00-21.29 164 139 Vertical Signal Frequency (MHz) Corrected Factor (db) Corrected QP Level db(uv/m) 3 Meter Limits db(uv/m) Margin (db) Angle of Turner (degree) Height of Tower (cm) 1 34.6500 17.02 41.55 50.00-8.45 188 112 2 93.0499 8.89 25.40 50.00-24.60 149 100 3 141.5500 11.62 27.92 50.00-22.08 203 100 Test Equipment Manufacturer Model Serial No. Last Cal. Cal. Due Date Test Receiver HP 85462A 3704A00349 11/29/07 11/28/09 Bilog Antenna Sunol JB5 A110503 03/28/08 03/27/10 Note: All testing were performed using internationally recognized standards. All test instruments were calibrated and traceable to the National Institute of Standards and Technology (NIST). SIGNED BY: ENGINEER REVIEWED BY: SENIOR ENGINEER Prepared by ECMG Worldwide Certification Solution, Inc. Page 21 of 43

EUT Model: Release 3.0 Hardware and Software Radiated Emission Test Set-up Front View Radiated Emission Test Set-up Back View Prepared by ECMG Worldwide Certification Solution, Inc. Page 22 of 43

ATTACHMENT 3 - ESD IMMUNITY TEST CLIENT: Dorman Long Engineering Technology Consultant (Shanghai) Co., Ltd. TEST STANDARD: EN 61326-1: 2006 MODEL NUMBER: Release 3.0 Hardware and Software PRODUCT: DL-P40 Computer Control System SERIAL NO.: Engineering Sample EUT DESIGNATION: Control Equipment TEMPERATURE: 22 C HUMIDITY: 56%RH ATM PRESSURE: 101.1 kpa GROUNDING: Grounding TESTED BY: Edison Li DATE OF TEST: 2009, July 27 TEST REFERENCE: IEC 61000-4-2, Edition 2.0 (2008) TEST PROCEDURE: The EUT was set up according to the guidelines of IEC 61000-4-2 for tabletop equipment. A calibrated ESD gun was then used to test a predetermined set of points of the EUT as described below. Air Discharge: The ESD was applied to all normally accessible points of the EUT. The test was performed as follows: - Single discharges; - ±8kV at Air Discharge (for nonconductive parts); - All severity levels were tested stepped up to the maximum required level; - At least 10 discharges each (positives and negatives); - Intervals of at least 1 second between successive discharges. Direct Contact Discharge: The discharges were applied to all conductive surfaces, to the horizontal coupling plane and on a vertical coupling metal plate of 50 cm x 50 cm at front, left and right of the EUT. (At 0.1 m from EUT) The test was performed as follows: - Single discharges; - ±4kV at Contact Discharge (for conductive parts); - All severity levels were tested stepped up to the maximum required level; - At least 10 discharges each (positives and negatives); - Intervals of at least 1 second between successive discharges. Continue on to next page Prepared by ECMG Worldwide Certification Solution, Inc. Page 23 of 43

TEST VOLTAGE: RESULTS: CHANGES OR MODIFICATIONS: 24V DC The EUT meets the requirements of IEC 61000-4-2 for Electrostatic Discharge ±4KV at Contact Discharge and ±4kV at Air Discharge. No performance degradation detected during this test. There were no modifications installed by ECMG Worldwide Certification Solution, Inc. (China) test personnel. M. UNCERTAINTY: Discharge: Current: ± 10% (first peak), ESD Voltage: ± 5% of reading ± 0.2kV Prepared by ECMG Worldwide Certification Solution, Inc. Page 24 of 43

AIR DISCHARGE TEST LEVELS: LEVEL 1 LEVEL 2 LEVEL 3 LEVEL 4 1 kv 2 kv 3 kv 4kV 6 kv 8 kv 10 kv 12 kv 15 kv - + - + - + TO EUT: FRONT X X X X BACK X X X X SIDE X X X X DIRECT CONTACT DISCHARGE TEST LEVELS: LEVEL 1 LEVEL 2 LEVEL 3 LEVEL 4 1 kv 2 kv 3 kv 4 kv 5 kv 6 kv 7 kv 8 kv - + - + TO EUT: FRONT X X X X BACK X X X X SIDE THRU HCP: FRONT X X X X BACK X X X X LEFT X X X X RIGHT X X X X THRU VCP: FRONT X X X X BACK X X X X LEFT X X X X RIGHT X X X X Test Equipment Manufacturer Model Serial No. Last Cal. Cal. Due Date Electrostatic Discharge Haefely PSD25B 083706-23 12/04/07 12/03/09 Note: All testing were performed using internationally recognized standards. All test instruments were calibrated. SIGNED BY: ENGINEER REVIEWED BY: SENIOR ENGINERR Prepared by ECMG Worldwide Certification Solution, Inc. Page 25 of 43

EUT Model: Release 3.0 Hardware and Software Electrostatic Discharge Test Set-up Prepared by ECMG Worldwide Certification Solution, Inc. Page 26 of 43

For Power Pack Node Contact Discharge Air Discharge Contact and Air Discharge Test Points - Front View Contact Discharge Contact Discharge Test Points - Rear View Prepared by ECMG Worldwide Certification Solution, Inc. Page 27 of 43

For Jack Node Contact Discharge Air Discharge Contact and Air Discharge Test Points - Front View Contact Discharge Contact Discharge Test Points - Rear View Prepared by ECMG Worldwide Certification Solution, Inc. Page 28 of 43

ATTACHMENT 4 - RADIATED SUSCEPTIBILITY IMMUNITY TEST CLIENT: Dorman Long Engineering Technology Consultant (Shanghai) Co., Ltd. TEST STANDARD: EN 61326-1: 2006 MODEL NUMBER: Release 3.0 Hardware and Software PRODUCT: DL-P40 Computer Control System SERIAL NO.: Engineering Sample EUT DESIGNATION: Control Equipment TEMPERATURE: 22 C HUMIDITY: 56%RH ATM PRESSURE: 101.1 kpa GROUNDING: Grounding TESTED BY: Chen Yegang DATE OF TEST: 2009, July 28 TEST REFERENCE: IEC 61000-4-3: Edition 3.1 (2008) TEST PROCEDURE: The EUT was set up according to the guidelines of IEC 61000-4-3 for tabletop equipment. Four sides of the EUT were subjected successively to horizontal and vertical electric fields as described below. - frequency range was from 80 MHz - 2700 MHz; - 80 % amplitude modulated with a 1 khz sine-wave; - with a minimum 10V/m intensity at 3 meters for 80MHHz 1GHz, 3V/m intensity at 1 meter for 1.4GHz 2GHz, 1V/m intensity at 1 meter for 2.0GHz 2.7GHz; - step size of 1% of fundamental of linear interpolation between points; - Dwell time set to 4 sec.; - With 1 meter of the I/O cables and P/S cable exposed to the field if possible. TEST VOLTAGE: RESULTS: CHANGES OR MODIFICATIONS: 24V DC The EUT meets the requirements of IEC 61000-4-3 for Radiated Susceptibility requirement. No performance degradation detected during this test. There were no modifications installed by ECMG Worldwide Certification Solution, Inc. (China) test personnel. M. UNCERTAINTY: Freq.: ± 2 parts in 10 6, Amp. ± 4.0dB Prepared by ECMG Worldwide Certification Solution, Inc. Page 29 of 43

Test No.# Frequency [MHz] Test level [V/m] Amplitude Modulated Pass/Fail Performance criterion 1 80MHz~1000MHz 10 V/m 80%AM (1kHz) Pass A 2 1400MHz~2000MHz 3V/m 80%AM (1kHz) Pass A 3 2000MHz~2700MHz 1V/m 80%AM (1kHz) Pass A Test Equipment Manufacturer Model Serial No. Last Cal. Cal. Due Date Signal Generator IFN 2023B Power Amplifier Shaffner CBA9426 DZ-C-A1-04- 21-0 DZ-A-A1-52- 09-0 03/02/09 01/03/10 07/15/08 07/14/10 Log-Periodic Antenna Shaffner CBL6112B DZ-C-A1-2705- 27 07/17/07 07/16/10 Note: All testing were performed using internationally recognized standards. All test instruments were calibrated. SIGNED BY: ENGINEER REVIEWED BY: SENIOR ENGINEER Prepared by ECMG Worldwide Certification Solution, Inc. Page 30 of 43

EUT Model: Release 3.0 Hardware and Software Radiated Susceptibility Test Set-up View Prepared by ECMG Worldwide Certification Solution, Inc. Page 31 of 43

ATTACHMENT 5- EFT IMMUNITY TEST CLIENT: Dorman Long Engineering Technology Consultant (Shanghai) Co., Ltd. TEST STANDARD: EN 61326-1: 2006 MODEL NUMBER: Release 3.0 Hardware and Software PRODUCT: DL-P40 Computer Control System SERIAL NO.: Engineering Sample EUT DESIGNATION: Control Equipment TEMPERATURE: 22 C HUMIDITY: 56%RH ATM PRESSURE: 101.1 kpa GROUNDING: Grounding TESTED BY: Chen Yegang DATE OF TEST: 2009, July 28 TEST REFERENCE: IEC 61000-4-4: Edition 2.0 (2007) TEST PROCEDURE: The EUT was set up according to the guidelines of IEC 61000-4-4 for tabletop equipment. The AC power supply line of the EUT was then coupled through a Capacitive Coupler using a waveform described in standard of a Fast Transient (EFT) generator. Burst signals described below were then introduced into the individual power lines and its combinations. The EUT was then monitored and evaluated for results. The burst are specified as follows: - 5 khz burst rate, 5ns rise-time, and 50ns hold-time; - 3 Hz burst repetition rate; - Test levels from 0.5kV to 2.0 kv (positive and negative bursts); - Dwell time set to 120 sec. TEST VOLTAGE: RESULTS: CHANGES OR MODIFICATIONS: 24V DC The EUT meets the requirements of IEC 61000-4-4 for Electrical Fast Transient/Burst to ±2.0kV for DC Power Supply line and at ±1kV for I/O line. No performance degradation detected during this test. There were no modifications installed by ECMG Worldwide Certification Solution, Inc. (China) test personnel. M. UNCERTAINTY: Voltage: ± 2% Pulse Duration ± 0.2% Prepared by ECMG Worldwide Certification Solution, Inc. Page 32 of 43

For DC Power Line Test Levels (kv) Inject Line +0.5-0.5 +1.0-1.0 +2.0-2.0 Result DC-mains (+&-) A A A A A A PASS *Performance criterion B For CAN A Line Test Levels (kv) Inject Line +0.5-0.5 +1.0-1.0 +2.0-2.0 Result (L) A A A A N/A N/A PASS *Performance criterion B For CAN B Line Test Levels (kv) Inject Line +0.5-0.5 +1.0-1.0 +2.0-2.0 Result (L) A A A A N/A N/A PASS *Performance criterion B Test Equipment Manufacturer Model No. Serial No. Cal Date Cal Due Fast Transient/ Burst Generator Schaffner NSG2025 DZ-A-A1-52- 12-0 07/14/08 07/13/10 Coupling Clamp Schaffner CDN126 DZ-A-A1-52- 12-1 Shielding Room --- JPH DZ-A-A1-73- 008 07/14/08 07/13/10 06/13/07 06/12/12 Note: All testing were performed using internationally recognized standards. All test instruments were calibrated and traceable to the National Institute of Standards and Technology (NIST). SIGNED BY: ENGINEER REVIEWED BY: SENIOR ENGINEER Prepared by ECMG Worldwide Certification Solution, Inc. Page 33 of 43

EUT Model: Release 3.0 Hardware and Software Electrical Fast Transient/Burst Test Set-up Prepared by ECMG Worldwide Certification Solution, Inc. Page 34 of 43

ATTACHMENT 6 - SURGE IMMUNITY TEST CLIENT: Dorman Long Engineering Technology Consultant (Shanghai) Co., Ltd. TEST STANDARD: EN 61326-1: 2006 MODEL NUMBER: Release 3.0 Hardware and Software PRODUCT: DL-P40 Computer Control System SERIAL NO.: Engineering Sample EUT DESIGNATION: Control Equipment TEMPERATURE: 22 C HUMIDITY: 56%RH ATM PRESSURE: 101.1 kpa GROUNDING: Grounding TESTED BY: Edison Li DATE OF TEST: 2009, July 27 TEST REFERENCE: IEC 61000-4-5: Edition 2.0 (2005) TEST PROCEDURE: The EUT was set up according to the guidelines of IEC 61000-4-5 for tabletop equipment. The AC power cord of the EUT was then plugged into a surge generator. Power surges described below were then introduced to differential line mode and common line mode. The EUT was then monitored and evaluated for results. The surge pulses are specifies as follows: - 1.2µs rise-time, 50µs hold-time; - 5 positive and negative pulsed per combination; - Pulse rate at one per minute; - Test levels from 0.5kV to 1.0kV for differential mode and from 0.5kV to 2.0kV for common mode TEST VOLTAGE: RESULTS: CHANGES OR MODIFICATIONS: 24V DC The EUT meets the requirements of IEC 61000-4-5 for Surge Immunity at ±1kV differential mode and ±2kV common mode for power line and at ±1kV for I/O line. No performance degradation detected during this test. There were no modifications installed by ECMG Worldwide Certification Solution, Inc. (China) test personnel. M. UNCERTAINTY Source Impedance: ± 0.25Ω; Amp.: ± 20% Prepared by ECMG Worldwide Certification Solution, Inc. Page 35 of 43

For DC Power Line Test Levels (kv) Test Points +0.5-0.5 +1.0-1.0 +2.0-2.0 DC Main (+ -- -) Differential Mode A A A A N/A N/A DC Main (+&- -- Ground) Common Mode A A A A A A *Performance criterion B For CAN A Line Test Levels (kv) Test Points +0.5-0.5 +1.0-1.0 +2.0-2.0 I/O Line(Shielding -- Ground) Common Mode A A A A N/A N/A *Performance criterion B For CAN B Line Test Levels (kv) Test Points +0.5-0.5 +1.0-1.0 +2.0-2.0 I/O Line(Shielding -- Ground) Common Mode A A A A N/A N/A *Performance criterion B Test Equipment Manufacturer Model No. Serial No. Cal Date Cal Due Surge Tester LIONCEL LSG-506A 001 05/13/09 05/12/10 Note: All testing were performed using internationally recognized standards. All test instruments were calibrated and traceable to the National Institute of Standards and Technology (NIST). SIGNED BY: ENGINEER REVIEWED BY: SENIOR ENGINEER Prepared by ECMG Worldwide Certification Solution, Inc. Page 36 of 43

EUT Model: Release 3.0 Hardware and Software Surge Test Set-up Prepared by ECMG Worldwide Certification Solution, Inc. Page 37 of 43

ATTACHMENT 7 - CONDUCTED IMMUNITY TEST CLIENT: Dorman Long Engineering Technology Consultant (Shanghai) Co., Ltd. TEST STANDARD: EN 61326-1: 2006 MODEL NUMBER: Release 3.0 Hardware and Software PRODUCT: DL-P40 Computer Control System SERIAL NO.: Engineering Sample EUT DESIGNATION: Control Equipment TEMPERATURE: 22 C HUMIDITY: 56%RH ATM PRESSURE: 101.1 kpa GROUNDING: Grounding TESTED BY: Chen Yegang DATE OF TEST: 2009, July 28 TEST REFERENCE: IEC 61000-4-6: Edition 3.0 (2008) TEST PROCEDURE: The EUT was set up according to the guidelines of IEC 61000-4-6 for tabletop equipment. A current injection clamp was then used to inductively couple the stimulus as described below into the power cable. The EUT was then monitored and evaluated for results. - Frequency range from 0.15 to 80MHz; - Step size of 1% of fundamental of linear interpolation between points; - Voltage level of minimum 3 Volts (rms) before adding modulation; - 80% amplitude modulated with a 1kHz sine-wave - Dwell time set to 4 sec. TEST VOLTAGE: 24V DC RESULTS: The EUT meets the requirements of IEC 61000-4-6 for Conducted Immunity at 3 V(rms) with 1kHz sine-wave amplitude modulation for DC power line and I/o line. No performance degradation detected during this test. CHANGES OR MODIFICATIONS: There were no modifications installed by ECMG Worldwide Certification Solution, Inc. (China) test personnel. M. UNCERTAINTY: Freq.: ± 12Hz; Amp.: ± 1.5dB Prepared by ECMG Worldwide Certification Solution, Inc. Page 38 of 43

For DC Power Line Test No.# Frequency [MHz] Test level [V] Amplitude Modulated Pass/Fail Performance criterion 1 150kHz~80MHz 3 V 80%AM (1kHz) Pass A For CAN A Line Test No.# Frequency [MHz] Test level [V] Amplitude Modulated Pass/Fail Performance criterion 1 150kHz~80MHz 3 V 80%AM (1kHz) Pass A For CAN B Line Test No.# Frequency [MHz] Test level [V] Amplitude Modulated Pass/Fail Performance criterion 1 150kHz~80MHz 3 V 80%AM (1kHz) Pass A Test Equipment Manufacturer Model No. Serial No. Cal Date Cal Due RF Generator Schaffner NSG2070 DZ-A-A1-52- 11-0 EM Clamp Schaffner KEMZ801 DZ-A-A1-52- 11-1 Shielding Room --- JPH DZ-A-A1-73- 008 07/14/08 07/13/10 07/14/08 07/13/10 06/13/07 06/12/12 Note: All testing were performed using internationally recognized standards. All test instruments were calibrated and traceable to the National Institute of Standards and Technology (NIST). SIGNED BY: ENGINEER REVIEWED BY: SENIOR ENGINEER Prepared by ECMG Worldwide Certification Solution, Inc. Page 39 of 43

EUT Model: Release 3.0 Hardware and Software Conducted Immunity Test Set-up Prepared by ECMG Worldwide Certification Solution, Inc. Page 40 of 43

ATTACHMENT 8 - POWER FREQUENCY MAGNETIC FIELD IMMUNITY TEST CLIENT: Dorman Long Engineering Technology Consultant (Shanghai) Co., Ltd. TEST STANDARD: EN 61326-1: 2006 MODEL NUMBER: Release 3.0 Hardware and Software PRODUCT: DL-P40 Computer Control System SERIAL NO.: Engineering Sample EUT DESIGNATION: Control Equipment TEMPERATURE: 22 C HUMIDITY: 56%RH ATM PRESSURE: 101.1 kpa GROUNDING: Grounding TESTED BY: Chen Yegang DATE OF TEST: 2009, July 28 TEST REFERENCE: IEC 61000-4-8: Edition 1.1 (2001) TEST PROCEDURE: The EUT was set up according to the guidelines of IEC 61000-4-8 for tabletop equipment. For tabletop equipment, a calibrated 1 square meter magnetic loop was used to test the EUT in its x, y, and z-axis. A current generator was used to provide power to the magnetic loop and generate the required magnetic field level. The EUT was centered in the loop and then monitored and evaluated for results. For the tabletop or equipment larger than the loop, the proximity method of testing was adopted to accomplish the test. The loop was moved as close as possible to the most probable susceptible areas of the EUT. The EUT was then monitored and evaluated for results The magnetic field are specified as follows: - Test levels of 30A/m, 50Hz - Dwell time set to 10 minutes. TEST VOLTAGE: RESULTS: CHANGES OR MODIFICATIONS: DC 24V The EUT meets the requirements of IEC 61000-4-8 for Power Frequency Magnetic Field Test at 30A/m, 50Hz. No performance degradation detected during this test. There were no modifications installed by ECMG Worldwide Certification Solution, Inc (China) test personnel. M. UNCERTAINTY: Voltage: ± 0.5% + 0.3V; Freq.: 0.01% + 0.01Hz Prepared by ECMG Worldwide Certification Solution, Inc. Page 41 of 43

Orientation Field Performance Criterion Result X 30 A/m, 50Hz A Pass Y 30 A/m, 50Hz A Pass Z 30 A/m, 50Hz A Pass Test Equipment Manufacturer Model No. Serial No. Cal Date Cal Due Power Supply Schaffner NSG1007 DZ-A-A2-32- 04-1 03/05/09 03/04/11 Power Frequency Generator Power Frequency Coil Schaffner INA2141 DZ-A-A2-32- 04-0 Schaffner INA702 DZ-A-A2-32- 04-2 03/05/09 03/04/11 03/05/09 03/04/11 Note: All testing were performed using internationally recognized standards. All test instruments were calibrated and traceable to the National Institute of Standards and Technology (NIST). SIGNED BY: ENGINEER REVIEWED BY: SENIOR ENGINEER Prepared by ECMG Worldwide Certification Solution, Inc. Page 42 of 43

EUT Model: Release 3.0 Hardware and Software Power Frequency Magnetic Field Test Set-up Prepared by ECMG Worldwide Certification Solution, Inc. Page 43 of 43