1 198 Kezhu Road, Scientech Park, Guangzhou Economic & Technological Development District, Guangzhou, China Telephone: +86 (0) Fax: +86 (0) Page: 1 of 58 1 Cover Page Application No.: Applicant: TEST REPORT GZEM IT Shenzhen Gembird Electronics Ltd. Equipment Under Test (EUT): EUT Name: Item No.: Trade mark: Standards: Universal laptop power adapter NPA-AC2, NPA-AC2D, NPA-120D Please refer to section 3 of this report which indicates which item was actually tested and which were electrically identical. Gembird EN 55022:2006+A1:2007, EN 55024:1998+A1:2001+A2:2003, EN :2006+A2:2009, EN :2008. Date of Receipt: Date of Test: to Date of Issue: Test Result : Pass* * In the configuration tested, the EUT complied with the standards specified above. The CE mark as shown below can be used, under the responsibility of the manufacturer, after completion of an EC Declaration of Conformity and compliance with all relevant EC Directives. Stephen Guo Manager The manufacturer should ensure that all products in series production are in conformity with the product sample detailed in this report. If the product in this report is used in any configuration other than that detailed in the report, the manufacturer must ensure the new system complies with all relevant standards. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government. All test results in this report can be traceable to National or International Standards. This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at and, for electronic format documents, subject to Terms and Conditions for Electronic Documents at Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company s findings at the time of its intervention only and within the limits of Client s instructions, if any. The Company s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only

2 Page: 2 of 58 2 Version Revision Record Version Chapter Date Modifier Remark Original Authorized for issue by: Tested By to (Kobe Jian) /Project Engineer Date Prepared By (Millie Li) /Clerk Date Checked By (Stephen Guo) /Reviewer Date

3 Page: 3 of 58 3 Test Summary Electromagnetic Interference (EMI) Test Test Requirement Test Method Class / Severity Result Conducted Emission (150KHz to 30MHz) Conducted Emission on Telecommunication (150KHz to 30MHz) Radiated Emission, (30MHz to 1GHz) Radiated Emission above 1 GHz Harmonic Emission on AC, (100 Hz to 2 khz) EN 55022:2006 +A1:2007 EN 55022:2006 +A1:2007 EN 55022:2006 +A1:2007 EN 55022:2006 +A1:2007 EN :2006 +A2:2009 EN 55022:2006 +A1:2007 Class B PASS N/A Class B N/A EN 55022:2006 +A1:2007 Class B PASS ** N/A Class B N/A EN :2006 +A2:2009 Flicker Emission on AC EN :2008 EN :2008 Electromagnetic Susceptibility (EMS) ESD Radiated Immunity, (80MHz to 1 GHz) Electrical Fast Transients (EFT) on AC Class D Clause 5 of EN PASS PASS Test Test Requirement Test Method Class / Severity Result Surge Immunity on AC Surge Immunity on telecommunication Injected Currents on AC,(150kHz to 80MHz) Power Frequency Magnetic Field Voltage Dips and Interruptions on AC * U T is the nominal supply voltage EN 55024:1998 +A1:2001+A2:2003 EN 55024:1998 +A1:2001+A2:2003 EN 55024:1998 +A1:2001+A2:2003 EN 55024:1998 +A1:2001+A2:2003 EN 55024:1998 +A1:2001+A2:2003 EN 55024:1998 +A1:2001+A2:2003 EN 55024: A1:2001+A2:2003 EN 55024:1998 +A1:2001+A2:2003 EN :2009 EN :2006 +A1: 2008 Contact ±4 kv Air ±8 kv 3V/m 80%, 1kHz, AM PASS PASS EN :2004 AC ± 1.0kV PASS EN :2006 ±1kV D.M. ±2kV C.M. PASS N/A ±1kV C.M. N/A EN :2009 N/A EN :2004 D.M. Differential Mode C.M. Common Mode EUT In this whole report EUT means Equipment Under Test. 3Vrms (emf), 80%, 1kHz Amp. Mod. 50 Hz 1 A/m 0 % U T * for 0.5per 0 % U T * for 250per 70 % U T * for 25per PASS N/A PASS

4 Page: 4 of 58 Remark : N/A: Not applicable, please refer to section 7.2 & 7.4 & 8.6 & 8.8 of this report for details. Item no.: NPA-AC2, NPA-AC2D, NPA-120D According to the confirmation from the applicant, two models are for India version and they are totally identical in mechanical and electrical construction, except for the item No. for the marketing requirement. Therefore only one model NPA-120D was tested in this report. **: The EUT passed Radiated Emission, (30MHz to 1GHz) test after the modification as the below: Add two ferrite cores (4*4*1.6) for the switching tube as the following picture shown.

5 Page: 5 of 58 4 Contents 1 COVER PAGE VERSION TEST SUMMARY CONTENTS GENERAL INFORMATION Client Information General Description of E.U.T Details of E.U.T Description of Support Units Test Facility Test Location Deviation from Standards Abnormalities from Standard Conditions Monitoring of EUT for All Immunity Test EQUIPMENT USED DURING TEST EMISSION TEST RESULTS Conducted Emissions Mains Terminals, 150 KHz to 30MHz Conducted Emissions at Telecommunication ports, 150 KHz to 30 MHz Radiated Emissions, 30MHz to 1GHz Radiated Emissions above 1 GHz Harmonics Test Results Flicker Test Results IMMUNITY TEST RESULTS Performance Criteria Description in Clause 7 of EN ESD Radiated Immunity Electrical Fast Transients (EFT) Surge Surge immunity on telecommunication port Conducted Immunity 0.15 MHz to 80 MHz Power Frequency Magnetic Field Immunity Voltage Dips and Interruptions... 47

6 Page: 6 of 58 9 PHOTOGRAPHS Conducted Emissions Mains Terminals Test Setup Radiated Emissions, 30MHz to 1GHz Test Setup Harmonics and Flicker Test Results Test Setup ESD Test Setup Radiated Immunity Test Setup EFT, Surge, Voltage Dips and Interruptions on AC Test Setup Conducted Immunity on AC Test Setup EUT Constructional Details

7 Page: 7 of 58 5 General Information 5.1 Client Information Applicant: Address of Applicant: Shenzhen Gembird Electronics Ltd. 2nd Floor, Building B, Shifeng industry District, Huaning Road, Dalang Street, Longhua, Shenzhen 5.2 General Description of E.U.T. EUT Name: Item No.: Trade mark: 5.3 Details of E.U.T. Universal laptop power adapter NPA-AC2, NPA-AC2D, NPA-120D Gembird Power Supply: Input: AC V Output: DC 12-20V, Max: 6A DC 5V, Max: 0.5A Max output power: 120W Power Cord: 5.4 Description of Support Units 1.8 m x 3 wires unscreened AC cable 1.2 m unscreened DC output with ferrite core cable 1.2 m unscreened USB DC output cable supply by SGS The EUT has been tested with resistor as load and current meter as monitor. Mode Voltage Current Power Full load(1.875ω) 15 V 8 A 120 W Half load(3.75ω) 15 V 4 A 60 W

8 Page: 8 of Test Facility The test facility is recognized, certified, or accredited by the following organizations: NVLAP (Lab Code: ) SGS-CSTC Standards Technical Services Co., Ltd., Guangzhou EMC Laboratory is recognized under the National Voluntary Laboratory Accreditation Program (NVLAP/NIST). NVLAP Code: ACMA SGS-CSTC Standards Technical Services Co., Ltd., EMC Laboratory can also perform testing for the Australian C-Tick mark as a result of our NVLAP accreditation. SGS UK(Certificate No.: 32), SGS-TUV SAARLAND and SGS-FIMKO Have approved SGS-CSTC Standards Technical Services Co., Ltd., EMC Laboratory as a supplier of EMC TESTING SERVICES and SAFETY TESTING SERVICES. CNAS (Lab Code: L0167) SGS-CSTC Standards Technical Services Co., Ltd., EMC Laboratory has been assessed and in compliance with CNAS-CL01:2006 accreditation criteria for testing laboratories (identical to ISO/IEC 17025:2005 General Requirements) for the Competence of Testing Laboratories. FCC (Registration No.: ) SGS-CSTC Standards Technical Services Co., Ltd., EMC Laboratory has been registered and fully described in a report filed with the (FCC) Federal Communications Commission. The acceptance letter from the FCC is maintained in our files. Registration , May 31, Industry Canada (Registration No.: 4620B-1) The 3m/10m Alternate Semi-anechoic chamber of SGS-CSTC Standards Technical Services Co., Ltd., has been registered by Certification and Engineering of Industry Canada for radio equipment testing with Registration No. 4620B-1. VCCI (Registration No.: R-2460 and C-2584) The 10m Semi-anechoic chamber and Shielded Room of SGS-CSTC Standards Technical Services Co., Ltd. have been registered in accordance with the Regulations for Voluntary Control Measures with Registration No.: R-2460 and C-2584 respectively. CBTL (Lab Code: TL129) SGS-CSTC Standards Technical Services Co., Ltd., E&E Laboratory has been assessed and fully comply with the requirements of ISO/IEC 17025:2005, the Basic Rules, IECEE 01: and Rules of procedure IECEE 02: , and the relevant IECEE CB-Scheme Operational documents.

9 Page: 9 of Test Location All tests were performed at: SGS-CSTC Standards Technical Services Co., Ltd., Guangzhou EMC Laboratory, 198 Kezhu Road, Scientech Park, Guangzhou Economic & Technology Development District, Guangzhou, China Tel: Fax: No tests were sub-contracted. 5.7 Deviation from Standards All Immunity tests to EN were performed in accordance with EN x and not IEC x. (x=2, 3, 4, 5, 6, 8, 11). 5.8 Abnormalities from Standard Conditions The EUT passed Radiated Emission, (30MHz to 1GHz) test after the modification. 5.9 Monitoring of EUT for All Immunity Test Audio: N/A Visual: Current meter and LED light display

10 Page: 10 of 58 6 Equipment Used during Test Conducted Emission No. Test Equipment Manufacturer Model No. Cal. Date (YYYY-MM-DD) Cal.Due date (YYYY-MM-DD) EMC0306 Shielding Room Zhong Yu 8 x 3 x 3.8 m 3 N/A N/A N/A EMC0118 Two-line v-netwok R&S ENV EMC0506 EMI Test Receiver Rohde & Schwarz ESCS EMC0107 Coaxial Cable SGS 2m N/A EMC0106 Voltage Probe SGS N/A N/A N/A N/A EMC0120 EMC0121 EMC Line ISN 4 Line ISN 2 Line ISN Fischer Custom Communications Inc. Fischer Custom Communications Inc. Fischer Custom Communications Inc. FCC-TLISN-T8-02 FCC-TLISN-T4-02 FCC-TLISN-T2-02 Serial No RE in Chamber No. Test Equipment Manufacturer Model No. Serial No. EMC0525 Compact Semi- Anechoic Chamber ChangZhou ZhongYu Cal. Date (YYYY-MM-DD) Cal.Due date (YYYY-MM-DD) N/A N/A EMC0522 EMI Test Receiver Rohde & Schwarz ESIB EMC0056 EMI Test Receiver Rohde & Schwarz ESCI N/A EMI Test Software Audix E3 N/A N/A N/A EMC0514 Coaxial cable SGS N/A N/A EMC0524 Bi-log Type Antenna Schaffner -Chase CBL6112B EMC0519 Bilog Type Antenna Schaffner -Chase CBL EMC0518 Horn Antenna Rohde & Schwarz HF EMC GHz Pre-Amplifier Agilent 8449B 3008A EMC0049 Amplifier Agilent 8447D 2944A EMC N Amplifier Sonama 310N EMC0523 Active Loop Antenna EMCO EMC m Semi- Anechoic Chamber ETS N/A N/A

11 Page: 11 of 58 Harmonics / Flicker test No. Test Equipment Manufacturer Model No. Serial No. Cal. Date (YYYY-MM-DD) Cal.Due date (YYYY-MM-DD) EMC0608 AC Power Source California 50001iX EMC0607 Power Analyzer California PAXS Electrostatic Discharge No. Test Equipment Manufacturer Model No. Serial No. Cal. Date (YYYY-MM-DD) Cal.Due date (YYYY-MM-DD) EMC0809 ESD Simulator EM Test AG Dito V EMC0804 ESD Ground Plane SGS 3m x 3m N/A N/A N/A EMC0077 Temperature, & Humidity Shanghai Meteorological Instrument factory Co., Ltd. ZJ1-2B Radiated Immunity No. Test Equipment Manufacturer Model No. Serial No. EMC0525 Compact 3m Semi- Anechoic Chamber Cal. Date (YYYY-MM-DD) Cal.Due date (YYYY-MM-DD) Changzhou zhongyu N/A N/A EMC0516 Signal Generator Rohde & Schwarz SMR EMC0915 Amplifier 20M-1GHz EMPOWER BBS2E4ALP EMC0914 Amplifier 800M- 2.5GHz EMPOWER BBS3Q5KIN EMC0904 Power Meter Rohde & Schwarz NRVS / EMC0071 URV5-Z2 Insert. Unit R&S URV5-Z EMC0917 EMC0907 EMC0908 Dual Directional Coupler Electric Field Probe Oscilloscope Type 485 EMCA Wandel & Goltermann EMC-20 M Tektronix 485 B EMC0909 Monitor System Mitsubish Corp. M-0552AB N/A N/A SEL0075 High Gain Horn Antenna (0.8-5GHz) Amplifier Research AT4002A N/A N/A N/A

12 Page: 12 of 58 EFT, Surge, Voltage dips and Interruption No. Test Equipment Manufacturer Model No. Serial No. EMC1010 EMC2012 EMC Immunity Test System Power-Electronics Measurement System Cal. Date (YYYY-MM-DD) Cal.Due date (YYYY-MM-DD) Thermo KeyTek Pro-Plus Tektronix TDS 744A N/A Conducted Immunity No. Test Equipment Manufacturer Model No. Serial No. Cal. Date (YYYY-MM-DD) Cal.Due date (YYYY-MM-DD) EMC1101 Signal Generator Rohde & Schwarz SMY / EMC1102 Amplifier MHz Ophirrf GRF EMC1103 Power Meter Rohde & Schwarz NRVS / EMC0071 URV5-Z2 Insert. Unit R&S URV5-Z EMC1105 EMC0908 Dual Directional coupler Oscilloscope Type 485 Werlatone Inc. C Tektronix 485 B EMC1108 CDN M3 Schaffner Chase CDN-M EMC1107 CDN M2 Schaffner Chase CDN-M EMC1120 Immunity S/W Ver 4.31 Schaffner Chase CIS9942 WHHPKB N/A N/A EMC1116 Current Probe Schaffner Chase CIP EMC1117 Current Probe Schaffner Chase CSP General used equipment No. Test Equipment Manufacturer Model No. Serial No. Cal. Date (YYYY-MM-DD) Cal.Due date (YYYY-MM-DD) EMC0006 DMM Fluke EMC0007 DMM Fluke

13 Page: 13 of 58 7 Emission Test Results 7.1 Conducted Emissions Mains Terminals, 150 KHz to 30MHz Test Requirement: EN Test Method: EN Test Voltage: 230V AC, 50Hz Test Date: Frequency Range: Detector: Class / Limit: 150KHz to 30MHz Peak for pre-scan Quasi-Peak and Average at frequency with maximum peak (9 khz resolution bandwidth) Class B Frequency range MHz Quasi-peak Class B Limits db (µv) Average 0.15 to to to to to NOTE 1 :The limit decreases linearly with the logarithm of the frequency in the range 0.15 MHz to 0.50 MHz. NOTE 2: The lower limit is applicable at the transition frequency E.U.T. Operation Operating Environment: Temperature: 23.0 C Humidity: 51 %RH Atmospheric Pressure: 1003 mbar EUT Operation: Pre-test the EUT in On Mode with full load and half load to find the worse case, compliance test the EUT in On Mode with full load as the worse case was found.

14 Page: 14 of Test Setup and Procedure 1. The mains terminal disturbance voltage test was conducted in a shielded room. 2. The EUT was connected to nominal power supply through a LISN 1 (Line Impedance Stabilization Network) which provides a 50Ω/50µH + 5Ω linear impedance. The power cables of all other units of the EUT were connected to a second LISN 2, which was bonded to the ground reference plane in the same way as the LISN 1 for the unit being measured. A multiple socket outlet strip was used to connect multiple power cables to a single LISN provided the rating of the LISN was not exceeded. 3. The tabletop EUT was placed upon a non-metallic table 0.8m above the ground reference plane. And for floor-standing arrangement, the EUT was placed on the horizontal ground reference plane, but separated from metallic contact with the ground reference plane by 0.1m of insulation. 4. The test was performed with a vertical ground reference plane. The rear of the EUT shall be 0.4 m from the vertical ground reference plane. The vertical ground reference plane was bonded to the horizontal ground reference plane. The LISN 1 was placed 0.8 m from the boundary of the unit under test and bonded to a ground reference plane for LISNs mounted on top of the ground reference plane. This distance was between the closest points of the LISN 1 and the EUT. All other units of the EUT and associated equipment was at least 0.8 m from the LISN 2.

15 Page: 15 of Measurement Data Pre-scan was performed with peak detected on both live and neutral cable. Quasi-peak & average measurements were performed at the frequencies which maximum peak emission level was detected. Please see the attached Quasi-peak and Average test results. Live Line: Peak Scan: Level (dbµv) Quasi-peak and Average measurement Level = Read Level + LISN Factor + Cable Loss.

16 Page: 16 of 58 Neutral Line: Peak Scan: Level (dbµv) Quasi-peak and Average measurement: Level = Read Level + LISN Factor + Cable Loss.

17 Page: 17 of Conducted Emissions at Telecommunication ports, 150 KHz to 30 MHz Test Requirement: EN Frequency Range: Class / Limit: Test Date: Remark: 150 KHz to 30 MHz Class B N/A: See Remark Below There is no need for Conducted Emission at telecommunication port test to be performed on this product in accordance with EN 55022:2006+A1:2007 because there is no telecommunication port in the product.

18 Page: 18 of Radiated Emissions, 30MHz to 1GHz Test Requirement: EN Test Method: EN Test Voltage: Test Date: Frequency Range: Measurement Distance: Detector: Class / Limit: 230V AC, 50Hz (initial test) (test after modification) 30MHz to 1GHz 10 m Peak for pre-scan Quasi-Peak if maximised peak within 6dB of limit (120 khz resolution bandwidth) Class B Frequency range MHz Quasi-peak limits db (µv/m) 30 to to At transitional frequencies the lower limit applies E.U.T. Operation Operating Environment: Temperature: 21.0 C Humidity: 57 %RH Atmospheric Pressure: 1009 mbar EUT Operation: Pre-test the EUT in On Mode with full load and half load to find the worse case, compliance test the EUT in On Mode with full load as the worse case was found.

19 Page: 19 of Test Setup and Procedure 1. The radiated emissions test was conducted in a semi-anechoic chamber. 2. Biconical and log periodic antenna was used for the frequency range from 30MHz to 1GHz 3. The EUT was connected to nominal power supply through a mains power outlet which was bonded to the ground reference plane; The mains cables were draped to the ground reference plane. The tabletop EUT was placed upon a non-metallic table 0.8m above the ground reference plane. And for floor-standing arrangement, the EUT was placed on the horizontal ground reference plane, but separated from metallic contact with the ground reference plane by 0.1m of insulation. 4. Before final measurements of radiated emissions, a pre-scan was performed in the spectrum mode with the peak detector to find out the maximum emissions spectrum plots of the EUT. 5. The frequencies of maximum emission were determined in the final radiated emissions measurement. At each frequency, the EUT was rotated 360, and the antenna was raised and lowered from 1 to 4 meters in order to determine the maximum disturbance. Measurements were performed for both horizontal and vertical antenna polarization.

20 Page: 20 of Measurement Data Vertical: Peak scan Level (dbµv/m) Quasi-peak measurement Level = Read Level + Antenna Factor + Cable Loss Preamp Factor.

21 Page: 21 of 58 Horizontal: Peak scan Level (dbµv/m) Quasi-peak measurement Level = Read Level + Antenna Factor + Cable Loss Preamp Factor.

22 Page: 22 of Radiated Emissions above 1 GHz Test Requirement: EN Frequency Range: 1 GHz to 6 GHz Measurement Distance: 3 m Class / Limit: Class B Test Date: N/A: See Remark Below Remark: There is no need for Radiated Emissions (above 1G) test to be performed on this product in accordance with EN 55022:2006+A1:2007 because the highest internal source is less than 108 MHz. For further details, please refer to Clause 6.2 of EN which states: If the highest frequency of the internal sources of the EUT is less than 108 MHz, the measurement shall only be made up to 1 GHz.

23 Page: 23 of Harmonics Test Results Test Requirement: EN Test Method: EN Test Voltage: Test Date: Frequency range: Measurement Time: 230V AC, 50Hz (initial test) (test after modification) 100Hz to 2kHz 3 min Detector: As per EN Class / Limit: E.U.T. Operation Operating Environment: Class A Temperature: 25.0 C Humidity: 50 %RH Atmospheric Pressure: 1005 mbar EUT Operation: Pre-test the EUT in On Mode with full load and half load to find the worse case, compliance test the EUT in On Mode with full load as the worse case was found.

24 Page: 24 of Test Setup and Procedure 1. The EUT was tested with the equipment configured to its rated current. 2. The measurements were carried out under steady conditions. When a piece of EUT is brought into operation or is taken out of operation, manually or automatically, harmonic currents and power are not taken into account at first 10s following the switching event. EUT shall not be in standby mode for more than 10% of any observation period. 3. Harmonics of the fundamental current were measured using a digital power meter with an analogue output and frequency analyser which was integrated in the harmonic and flicker test system. For each harmonic order, measure the 1.5 s smoothed r.m.s. harmonic current in each DFT time window and calculate the arithmetic average of the measured values from the DFT time windows, over the entire observation period. Each harmonic order, all 1.5 s smoothed r.m.s. harmonic current values and the average values for the individual harmonic currents, taken over the entire test observation period shall be less than or equal to the applicable limits.

25 Page: 25 of Measurement Data Harmonics Class-A per Ed. 3.0 (Run time) Test Result: Pass Source qualification: Normal Current & voltage waveforms Current (Amps) Voltage (Volts) Harmonics and Class A limit line European Limits Current RMS(Amps) Harmonic # Test result: Pass Worst harmonic was #9 with 88.03% of the limit.

26 Page: 26 of 58 Current Test Result Summary (Run time) Test Result: Pass Source qualification: Normal THC(A): 1.02 I-THD(%): POHC(A): POHC Limit(A): Highest parameter values during test: V_RMS (Volts): Frequency(Hz): I_Peak (Amps): I_RMS (Amps): I_Fund (Amps): Crest Factor: Power (Watts): Power Factor: Harm# Harms(avg) 100%Limit %of Limit Harms(max) 150%Limit %of Limit Status Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass

27 Page: 27 of Flicker Test Results Test Requirement: EN Test Method: EN Test Voltage: 230V AC, 50Hz Test Date: Measurement Time: 10 mins Detector: As per EN Class / Limit: Clause 5 of EN E.U.T. Operation Operating Environment: Temperature: 25.0 C Humidity: 50 %RH Atmospheric Pressure: 1005 mbar EUT Operation: Test in on mode with full load and then switch On/Off once Test Setup and Procedure 1. The test supply voltage (open-circuit voltage) was the rated voltage of the EUT. The test voltage was maintained within ±2 % of the nominal value. The frequency was 50 Hz ±0.5 %. 2. The voltage fluctuations and flicker were measured at the supply terminals of the EUT. 3. The observation period, Tp, for the assessment of flicker values by flicker measurement, flicker simulation, or analytical method was: for Pst, Tp = 10 min; for Plt, Tp = 2 h. The observation period included that part of the whole operation cycle in which the EUT produces the most unfavorable sequence of voltage changes.

28 Page: 28 of Measurement Data Flicker Test Summary per EN/IEC (Run time) Test Result: Pass Status: Test Completed Pst i and limit line European Limits Pst :23:12 Parameter values recorded during the test: Vrms at the end of test (Volt): Highest dt (%): 0.36 Test limit (%): 3.30 Pass Time(mS) > dt: 0.0 Test limit (ms): Pass Highest dc (%): 0.13 Test limit (%): 3.30 Pass Highest dmax (%): Test limit (%): 4.00 Pass Highest Pst (10 min. period): Test limit: Pass

29 Page: 29 of 58 8 Immunity Test Results 8.1 Performance Criteria Description in Clause 7 of EN Criterion A: Criterion B: Criterion C: The equipment shall continue to operate as intended without operator intervention. No degradation of performance or loss of function is allowed below a performance level specified by the manufacturer when the equipment is used as intended. The performance level may be replaced by a permissible loss of performance. If the minimum performance level or the permissible performance loss is not specified by the manufacturer, then either of these may be derived from the product description and documentation, and by what the user may reasonably expect from the equipment if used as intended. After the test, the equipment shall continue to operate as intended without operator intervention. No degradation of performance or loss of function is allowed, after the application of the phenomena below a performance level specified by the manufacturer, when the equipment is used as intended. The performance level may be replaced by a permissible loss of performance. During the test, degradation of performance is allowed. However, no change of operating state or stored data is allowed to persist after the test. If the minimum performance level (or the permissible performance loss) is not specified by the manufacturer, then either of these may be derived from the product description and documentation, and by what the user may reasonably expect from the equipment if used as intended. Loss of function is allowed, provided the function is self-recoverable, or can be restored by the operation of the controls by the user in accordance with the manufacturer s instructions. Functions, and/or information stored in non-volatile memory, or protected by a battery backup, shall not be lost.

30 Page: 30 of ESD Test Requirement: EN Test Method: EN Test Voltage: 230V AC, 50Hz Criterion Required: B Test Date: Discharge Impedance: 330 Ω / 150 pf Discharge Voltage: Air Discharge: 2, 4, 8 kv VCP, HCP: 4 kv Contact Discharge: 4 kv Polarity: Positive & Negative Number of Discharge: Minimum 10 times at each test point Discharge Mode: Single Discharge Discharge Period: 1 second minimum E.U.T. Operation Operating Environment: Temperature: 24.0 C Humidity: 52 %RH Atmospheric Pressure: 1008 mbar EUT Operation: Test the EUT in On Mode with full load and half load Test Setup and Procedure

Rated Power(W) 8W 2. EG-LED0840-01 8W 3. EG-LED1027-01 10W

Rated Power(W) 8W 2. EG-LED0840-01 8W 3. EG-LED1027-01 10W 14713221 001 Seite 2 von 37 Page 2 of 37 Model List: No Model Rated Voltage(V) 1. EG-LED0827-01 Rated Power(W) 8W 2. EG-LED0840-01 8W 3. EG-LED1027-01 10W 4. EG-LED1040-01 AC 100-240V, 10W 5. EG-LED1027-02

More information

SHENZHEN GEMBIRD ELECTRONICS LTD EMC REPORT

SHENZHEN GEMBIRD ELECTRONICS LTD EMC REPORT Shenzhen BST Technology Co., Ltd. SHENZHEN GEMBIRD ELECTRONICS LTD EMC REPORT Prepared For : Product Name: Model : Prepared By : SHENZHEN GEMBIRD ELECTRONICS LTD 5th Floor, Building B, Shifeng Industry

More information

EMC TEST REPORT For. Webcam. Model Number: CAM67U

EMC TEST REPORT For. Webcam. Model Number: CAM67U EMC TEST REPORT For Webcam Model Number: CAM67U Prepared for : Gembird Europe B.V. Wittevrouwen 56, 1358CD Almere, The Netherlands. Phone: +31-36-5211588 Prepared By : Shenzhen Meihua Electronic Technology

More information

SGS-CSTC Standards Technical Services (Shanghai) Co., Ltd.

SGS-CSTC Standards Technical Services (Shanghai) Co., Ltd. 588 West Jindu Road,Songjiang District,Shanghai,China Telephone: +86 (0) 21 6191 5666 Fax: +86 (0) 21 6191 5678 ee.shanghai@sgs.com Page: 1 of 23 1 Cover Page Application No.: Applicant: Manufacturer:

More information

Test Report. Prepared for: Technologic Systems, Inc. Model: TS-8820

Test Report. Prepared for: Technologic Systems, Inc. Model: TS-8820 Test Report Prepared for: Technologic Systems, Inc. Model: TS-8820 Description: Single Board Computer with Analog and Digital Inputs and Outputs, Relays, and RS-232/485 Ports To IEC 61000-6-1 (2005-03)

More information

EMC TEST REPORT For. Shenzhen Homelux Security Equipment Co., Ltd. Auto Dialer. Model No.: HX-GD20

EMC TEST REPORT For. Shenzhen Homelux Security Equipment Co., Ltd. Auto Dialer. Model No.: HX-GD20 EMC TEST REPORT For Shenzhen Homelux Security Equipment Co., Ltd Auto Dialer Model No.: HX-GD20 Prepared for : Shenzhen Homelux Security Equipment Co., Ltd Address : 4 th Floor, Building 5, Jiademaluan

More information

Test Report #: 1981-3 Date: April 8, 2005

Test Report #: 1981-3 Date: April 8, 2005 Test Report #: 1981-3 Date: April 8, 2005 CERTIFICATE #2316.01 Issued To: Bill Burks American Power Conversion 85 Rangeway Road North Billerica, MA 01862 USA 978-670-2440 Product Name/Description Model

More information

EMC TEST REPORT. Page: 1 of 38. Reference No.: WT08010091-S-E

EMC TEST REPORT. Page: 1 of 38. Reference No.: WT08010091-S-E Page: 1 of 38 EMC TEST REPORT Reference No. Applicant Address : WT08010091-S-E : Gembird Electronics Ltd. : Room 1709 A, News Building, #2 Shennan Zhong Lu, Shenzhen, China Equipment Under Test (EUT) :

More information

EN 301 489-17 v1.2.1 TEST REPORT FOR. 802.11ag/Draft 802.11n WLAN PCI-E Mini Card MODEL NUMBER: BCM94322MC REPORT NUMBER: 07U11529-5

EN 301 489-17 v1.2.1 TEST REPORT FOR. 802.11ag/Draft 802.11n WLAN PCI-E Mini Card MODEL NUMBER: BCM94322MC REPORT NUMBER: 07U11529-5 EN 301 489-17 v1.2.1 TEST REPORT FOR 802.11ag/Draft 802.11n WLAN PCI-E Mini Card MODEL NUMBER: BCM94322MC REPORT NUMBER: 07U11529-5 ISSUE DATE: JANUARY 29, 2008 Prepared for BROADCOM CORPORATION 190 MATHILDA

More information

Standard: EN 61000-4-2 :1995, EN 61000-4-3 :1996, ENV 50204 :1993, & EN 61000-4-4 :1995 Solid State Energy Meter

Standard: EN 61000-4-2 :1995, EN 61000-4-3 :1996, ENV 50204 :1993, & EN 61000-4-4 :1995 Solid State Energy Meter Standard: EN 61000-4-2 :1995, EN 61000-4-3 :1996, ENV 50204 :1993, & EN 61000-4-4 :1995 Model: Solid State Energy Meter Prepared for: Analog Devices, Inc. 804 Woburn Street Wilmington, MA 01887 Date of

More information

CE-EMC TEST- REPORT TEST REPORT NUMBER: EFSN14040316E-E01 EUROFINS TESTING TECHNOLOGY (SHENZHEN) CO., LTD.

CE-EMC TEST- REPORT TEST REPORT NUMBER: EFSN14040316E-E01 EUROFINS TESTING TECHNOLOGY (SHENZHEN) CO., LTD. EUROFINS TESTING TECHNOLOGY (SHENZHEN) CO., LTD. CE-EMC TEST- REPORT TEST REPORT NUMBER: EFSN14040316E-E01 Phone: +86-755-83585700 3A, F1.6, Tianfa Building, Tian an Cyber Park, Fax: +86-755-83585701 Futian

More information

TEST REPORT EN 55014-2 (1997) +A1 (2001)

TEST REPORT EN 55014-2 (1997) +A1 (2001) Page 1 of 23 TEST REPORT EN 55014-2 (1997) +A1 (2001) Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus Part 2: Immunity Report Reference No....

More information

Electromagnetic Compatibility Test Report Test results of Floww equipment

Electromagnetic Compatibility Test Report Test results of Floww equipment Electromagnetic Compatibility Test Report Test results of Floww equipment Reference number Status test report Brand Model number : 10C00357RPT01.doc : Final : Floww : mobilefloww screenfloww pocketfloww

More information

FCC PART 15B CLASS A MEASUREMENT AND TEST REPORT

FCC PART 15B CLASS A MEASUREMENT AND TEST REPORT FCC PART 15B CLASS A MEASUREMENT AND TEST REPORT For SAMBO HI TECH CO., LTD. 616-15, GANSUK4-DONG, NAMDONG-GU, INCHUN 405-810, KOREA Model: LSR700, SCI545HV1EF, SCI545HVEF This Report Concerns: Original

More information

CERTIFICATE. Issued Date:May. 18, 2006 Report No.: 065L043-IT-CE-P07V03. MGate MB318n(-T) (n=0~9,a~z)

CERTIFICATE. Issued Date:May. 18, 2006 Report No.: 065L043-IT-CE-P07V03. MGate MB318n(-T) (n=0~9,a~z) CERTIFICATE Issued Date:May. 18, 2006 Report No.: 065L043-IT-CE-P07V03 This is to certify that the following designated product Product Trade name Model Number : 1 Port Device Server : Moxa : NPort 5150(-T),

More information

Declaration of Conformity.

Declaration of Conformity. Declaration of Conformity. Type of equipment: Brand Name /Trade Mark: Type designation /model: Applicant: Network Camera SAMSUNG SND6011RP SAMSUNG TECHWIN CO., LTD. In accordance with the following Directives:

More information

Prepared for Dorman Long Engineering Technology Consultant (Shanghai) Co., Ltd.

Prepared for Dorman Long Engineering Technology Consultant (Shanghai) Co., Ltd. www.ecmg-global.com EMC TEST REPORT On Model Name: DL-P40 Computer Control System Model Number: Release 3.0 Hardware and Software Brand Name: Dorman Long Technology Ltd. Trade Mark: DLT Prepared for Dorman

More information

Measurement of RF Emissions from a Final Coat Electronics Corrosion Module

Measurement of RF Emissions from a Final Coat Electronics Corrosion Module Engineering Test Report No. 37802-02 Rev. A Measurement of RF Emissions from a Final Coat Electronics Corrosion Module For : Canadian Auto Preservation, Inc. 390 Bradwick Drive Concord, Ontario CANADA

More information

MYRICOM, INC. TEST REPORT FOR THE LAN INTERFACE CARD, M3F2-PCIXE-2

MYRICOM, INC. TEST REPORT FOR THE LAN INTERFACE CARD, M3F2-PCIXE-2 MYRICOM, INC. TEST REPORT FOR THE LAN INTERFACE CARD, M3F2-PCIXE-2 EN55024 (1998), EN61000-3-2 (2001), EN61000-3-3 (1995 W/A1: 98), EN55022 (1998) CLASS A, CISPR 22 (1997) CLASS A & FCC PART 15 SUBPART

More information

TEST REPORT Rapporto di prova EMC N 060406. Test facility site: via L. da Vinci, 92, Caravaggio (BG), Italy Sede laboratorio

TEST REPORT Rapporto di prova EMC N 060406. Test facility site: via L. da Vinci, 92, Caravaggio (BG), Italy Sede laboratorio TEST REPORT Rapporto di prova EMC N 060406 EUT: Organic Carbon Analyzer Analiuzzatore Carbonio Organico Model: TOCMETER Serial N : TM602 Client: TRE-ESSE s.r.l. Cliente Piazzale Europa 8 16036 Recco (GE),

More information

Declaration of Conformity.

Declaration of Conformity. Declaration of Conformity. Type of equipment: Brand Name /Trade Mark: Type designation /model: Applicant: PTZ CAMERA SAMSUNG SCP2371HP SAMSUNG TECHWIN CO., LTD. In accordance with the following Directives:

More information

Declaration of Conformity.

Declaration of Conformity. Declaration of Conformity. Type of equipment: Brand Name /Trade Mark: Type designation /model: Applicant: Network Camera SAMSUNG SNP-6200RHP SAMSUNG TECHWIN CO., LTD. In accordance with the following Directives:

More information

Declaration of Conformity.

Declaration of Conformity. Declaration of Conformity. Type of equipment: Brand Name /Trade Mark: Type designation /model: Applicant: Network Camera SAMSUNG SNO-6011RP SAMSUNG TECHWIN CO., LTD. In accordance with the following Directives:

More information

Variant Model No. The equipment under test has found to be compliant with the applied standards. (Refer to the attached test result for more detail.

Variant Model No. The equipment under test has found to be compliant with the applied standards. (Refer to the attached test result for more detail. EMC TEST REPORT Project No. LBE091881 Revision No. NONE Name of organization Samsung Electronics Co., Ltd. Applicant Address 416 Maetan 3-Dong,Yeongtong-Gu,Suwon-Si, Gyeonggi-Do, 443-742 Korea Date of

More information

TEST REPORT. CONCLUSION: The submitted sample was found to COMPLY with the test requirement

TEST REPORT. CONCLUSION: The submitted sample was found to COMPLY with the test requirement TEST REPORT Applicant Address Shenzhen Gembird Electronics Ltd. 5F, Building B, Shi-Feng Industrial Zone, Hua-Ning Rd., Xin-Wei Village, Da-Lang Street, Long-Hua, Bao-An Area, Shenzhen 518109, Guangdong

More information

Declaration of Conformity.

Declaration of Conformity. Declaration of Conformity. Type of equipment: Brand Name /Trade Mark: Type designation /model: Applicant: PTZ CAMERA SAMSUNG SNP-5300P SAMSUNG TECHWIN CO., LTD. In accordance with the following Directives:

More information

Declaration of Conformity.

Declaration of Conformity. Declaration of Conformity. Type of equipment Brand Name /Trade Mark Type designation /model Applicant Network Camera SAMSUNG SND-5083P SAMSUNG TECHWIN CO., LTD. In accordance with the following Directives

More information

EMC Test for Compliance with EU EMC Directive 2004/108/EU

EMC Test for Compliance with EU EMC Directive 2004/108/EU EMC Test for Compliance with EU EMC Directive 2004/108/EU Partial Test 12-12-2012 Standards Description EN 55022:2011 Information technology equipment - Radio disturbance characteristics - Limits and methods

More information

ELECTROMAGNETIC COMPATIBILITY TEST. Report reference N R-255 EMC 2010

ELECTROMAGNETIC COMPATIBILITY TEST. Report reference N R-255 EMC 2010 ELECTROMAGNETIC COMPATIBILITY TEST Report reference N R-255 EMC 2010 Constructor. Address Reference person. C LUCE S.r.l. Via Marmolada 5/11 20060 Truccazzano (MI) Italy ---- Product....... Model......

More information

MYRICOM, INC. TEST REPORT FOR THE SERVER RACK, 10G-PCIE2-8B2-2S & 10G-PCIE2-8B2-2QP FCC PART 15 SUBPART B SECTIONS 15.107 AND 15.109 CLASS A TESTING

MYRICOM, INC. TEST REPORT FOR THE SERVER RACK, 10G-PCIE2-8B2-2S & 10G-PCIE2-8B2-2QP FCC PART 15 SUBPART B SECTIONS 15.107 AND 15.109 CLASS A TESTING TESTING CERT #803.01, 803.02, 803.05, 803.06 MYRICOM, INC. TEST REPORT FOR THE SERVER RACK, 10G-PCIE2-8B2-2S & 10G-PCIE2-8B2-2QP FCC PART 15 SUBPART B SECTIONS 15.107 AND 15.109 CLASS A TESTING DATE OF

More information

Current Probes. User Manual

Current Probes. User Manual Current Probes User Manual ETS-Lindgren L.P. reserves the right to make changes to any product described herein in order to improve function, design, or for any other reason. Nothing contained herein shall

More information

Report No. 091028R-RFCEP02V01. Test Report. MS-6633, VS12489, NetOn AP1900. Transmitter Module. MSI / MS-6894

Report No. 091028R-RFCEP02V01. Test Report. MS-6633, VS12489, NetOn AP1900. Transmitter Module. MSI / MS-6894 Test Report Product Name All in one PC Model No. Transmitter Module. MSI / MS-6894 MS-6633, VS12489, NetOn AP1900 Applicant Address MICRO-STAR INT L Co., LTD. No. 69, Li-De St., Jung-He City, Taipei Hsien,

More information

LAB 1 TECHNICAL DOC 3 IN ONE LAB DEVICE. Velleman Legen Heirweg 33 9890 Gavere Belgium

LAB 1 TECHNICAL DOC 3 IN ONE LAB DEVICE. Velleman Legen Heirweg 33 9890 Gavere Belgium LAB 1 TECHNICAL DOC 3 IN ONE LAB DEVICE Velleman Legen Heirweg 33 9890 Gavere Belgium SPECIFICATIONS DIGITAL MULTIMETER 3 1/2 backlit LCD Automatic polarity indication DC voltage 200mV to 600V in 5 steps

More information

Electromagnetic Compatibility Test Report. DC DC umodule Regulator LTM4613

Electromagnetic Compatibility Test Report. DC DC umodule Regulator LTM4613 Report No.: 0000091428 31160742.001 Page 1 of 36 Electromagnetic Compatibility Test Report Prepared in accordance with EN 55022: 2006, +A1: 2007 On DC DC umodule Regulator LTM4613 For Linear Technology

More information

EMC STANDARDS STANDARDS AND STANDARD MAKING BODIES. International. International Electrotechnical Commission (IEC) http://www.iec.

EMC STANDARDS STANDARDS AND STANDARD MAKING BODIES. International. International Electrotechnical Commission (IEC) http://www.iec. EMC STANDARDS The EMC standards that a particular electronic product must meet depend on the product application (commercial or military) and the country in which the product is to be used. These EMC regulatory

More information

Rules for Classification and Construction Additional Rules and Guidelines

Rules for Classification and Construction Additional Rules and Guidelines VI Rules for Classification and Construction Additional Rules and Guidelines 7 Guidelines for the Performance of Type Approvals 2 Test Requirements for Electrical / Electronic Equipment and Systems Edition

More information

Cond-IS RF Conducted Immunity System

Cond-IS RF Conducted Immunity System Cond-IS RF Conducted Immunity System About RF Conducted Immunity In the global contest of EMC testing for residential and industrial EUTs (Equipments Under Test) RF Conducted Immunity compliance verification

More information

RAPPORTO DI PROVA / TEST REPORT

RAPPORTO DI PROVA / TEST REPORT RAPPORTO DI PROVA / TEST REPORT Rif./Ref.No. FCCTR_130738-0 Data / Date: 17/09/2013 Pagine / Pages : 15 Scopo delle prove /Test object : Richiedente / Applicant : Persona di riferimento / Applicant s referee

More information

Clamp Filters that Suppress Emission Noise Provide Immunity Against Surge Noise

Clamp Filters that Suppress Emission Noise Provide Immunity Against Surge Noise TDK EMC Technology Product Section Clamp Filters that Suppress Emission Noise Provide Immunity Against Surge Noise TDK Shonai Corporation Satoru Saito Reduce Emission Noise from Cables Even if an electronic

More information

Waveguide Access Point WGA631. Product Guide

Waveguide Access Point WGA631. Product Guide Waveguide Access Point Product Guide Waveguide Access Point Contents 1. Description............................ 3 2. Application............................ 3 3. Technical data... 4 4. Physical interfaces......................

More information

RoHS APPROVAL SHEET. ituner 12V/6.6A SERIES NO. (E17) EA10953A. ( ) Edac Power Electronics (Suzhou) Co., Ltd. 59 No.59, Chang Sheng Road, Sheng Pu,

RoHS APPROVAL SHEET. ituner 12V/6.6A SERIES NO. (E17) EA10953A. ( ) Edac Power Electronics (Suzhou) Co., Ltd. 59 No.59, Chang Sheng Road, Sheng Pu, APPROVAL SHEET CUSTOMER ituner CUSTOMER P/N DESCRIPTION EDAC MODEL 12V/6.6A SERIES NO. (E17) EA10953A DATE 2010-06-22 REVISION 0 APPROVED DESIGN PREPARE RoHS CONCLUSION APPROVED CONDITON CUSTOMER S APP

More information

R&S ENY81-CA6 Coupling Network For radio disturbance and immunity measurements

R&S ENY81-CA6 Coupling Network For radio disturbance and immunity measurements R&S ENY81-CA6 Coupling Network For radio disturbance and immunity measurements on telecommunications ports Test & Measurement Data Sheet 01.00 R&S ENY81-CA6 Coupling Network At a glance The R&S ENY81-CA6

More information

Report Of. Shielding Effectiveness Test For. SafeSleeve Radiation Shielding Technology. Test Date(s): June 07 June 09, 2015

Report Of. Shielding Effectiveness Test For. SafeSleeve Radiation Shielding Technology. Test Date(s): June 07 June 09, 2015 Report Of Shielding Effectiveness Test For SafeSleeve Radiation Shielding Technology Test Date(s): June 07 June 09, 2015 Issue Date: June 10, 2015 UST Project No: 15-0137 Total Number of Pages Contained

More information

Report No. 099096R-RFCEP76V01. Test Report. Product Name All in one PC Model No. MS-6657,AE2220 Transmitter Module Realtek / RTL8191SE

Report No. 099096R-RFCEP76V01. Test Report. Product Name All in one PC Model No. MS-6657,AE2220 Transmitter Module Realtek / RTL8191SE Test Report Product Name All in one PC Model No. MS-6657,AE2220 Transmitter Module Realtek / RTL8191SE Applicant MICRO-STAR INT L Co., LTD. Address No. 69, Li-De St., Jung-He City, Taipei Hsien, Taiwan,

More information

FCC PART 15 SUBPART C EMI MEASUREMENT AND TEST REPORT

FCC PART 15 SUBPART C EMI MEASUREMENT AND TEST REPORT FCC PART 15 SUBPART C EMI MEASUREMENT AND TEST REPORT For AeroComm, Inc. 10981 Eicher Drive Lenexa, KS 66219 2003-05-22 This Report Concerns: Original Report Equipment Type: 900MHz Transceiver Test Engineer:

More information

Outer Diameter 23 φ mm Face side Dimension 20.1 φ mm. Baffle Opening. Normal 0.5 Watts Maximum 1.0 Watts Sine Wave.

Outer Diameter 23 φ mm Face side Dimension 20.1 φ mm. Baffle Opening. Normal 0.5 Watts Maximum 1.0 Watts Sine Wave. 1. MODEL: 23CR08FH-50ND 2 Dimension & Weight Outer Diameter 23 φ mm Face side Dimension 20.1 φ mm Baffle Opening 20.1 φ mm Height Refer to drawing Weight 4.0Grams 3 Magnet Materials Rare Earth Size φ 9.5

More information

AN003. Evaluation of Anechoic Chambers For EMC Measurements Using A CNE. Overview. CNE III 9kHz to 2GHz Conducted and radiated output

AN003. Evaluation of Anechoic Chambers For EMC Measurements Using A CNE. Overview. CNE III 9kHz to 2GHz Conducted and radiated output Evaluation of Anechoic Chambers For EMC Measurements Using A CNE Overview Anechoic chambers are used for EMC testing primarily for radiated emissions (RE) and radiated immunity (RI) in the frequency range

More information

Single-phase (220...240 V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

Single-phase (220...240 V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable Features 70.11 70.31 70.41 Electronic voltage monitoring relays for single and three-phase applications Multifunctional types, providing the flexibility of monitoring Undervoltage, Overvoltage, Window

More information

15 Series - Electronic step relay and dimmer. Features 15.91 15.51 15.81 SERIE

15 Series - Electronic step relay and dimmer. Features 15.91 15.51 15.81 SERIE Series - Electronic step relay and dimmer SERIE Features.91.51.81 Electronic step relay and dimmer for control of lighting levels Suitable for incandescent and halogen lighting loads (with or without transformer

More information

Verizon NEBS TM Compliance: Data Center Equipment NEBS Requirements Verizon Technical Purchasing Requirements VZ.TPR.9703 Issue 2, March 2012

Verizon NEBS TM Compliance: Data Center Equipment NEBS Requirements Verizon Technical Purchasing Requirements VZ.TPR.9703 Issue 2, March 2012 Verizon NEBS TM Compliance: Data Center Equipment NEBS Requirements Verizon Technical Purchasing Requirements VZ.TPR.9703 Issue 2, March 2012 CHANGE CONTROL RECORD: Version Date Action* Reason for Revision

More information

Telephone- and leased line modem for industrial applications TD-36

Telephone- and leased line modem for industrial applications TD-36 Telephone- and leased line modem for industrial applications TD-36 Modem for industrial PSTN- and leased line applications The TD-36 is an analogue V.34 PSTN modem as well as an industrial 2-wire leased

More information

RX-AM4SF Receiver. Pin-out. Connections

RX-AM4SF Receiver. Pin-out. Connections RX-AM4SF Receiver The super-heterodyne receiver RX-AM4SF can provide a RSSI output indicating the amplitude of the received signal: this output can be used to create a field-strength meter capable to indicate

More information

UNDERSTANDING AND CONTROLLING COMMON-MODE EMISSIONS IN HIGH-POWER ELECTRONICS

UNDERSTANDING AND CONTROLLING COMMON-MODE EMISSIONS IN HIGH-POWER ELECTRONICS Page 1 UNDERSTANDING AND CONTROLLING COMMON-MODE EMISSIONS IN HIGH-POWER ELECTRONICS By Henry Ott Consultants Livingston, NJ 07039 (973) 992-1793 www.hottconsultants.com hott@ieee.org Page 2 THE BASIC

More information

Automatic Distance/Time Speedmeter Handbook (Second Edition) Provisional

Automatic Distance/Time Speedmeter Handbook (Second Edition) Provisional Automatic Distance/Time Speedmeter Handbook (Second Edition) Provisional A Guide to Type-Approval Procedures for Automatic Distance/Time Speedmeters Used for Road Traffic Law Enforcement in Great Britain

More information

Predicting radiated emissions from cables in the RE02/RE102/DO- 160/SAE J113-41 test set up, using measured current in NEC and simple TX equations.

Predicting radiated emissions from cables in the RE02/RE102/DO- 160/SAE J113-41 test set up, using measured current in NEC and simple TX equations. Predicting radiated emissions from cables in the RE02/RE102/DO- 160/SAE J113-41 test set up, using measured current in NEC and simple TX equations. D. A. Weston RE02Tx.rep 14-6-2004 NARTE Certified EMC

More information

STRATO LED Drivers 70W, Single output

STRATO LED Drivers 70W, Single output Features STRATO switch mode driver technology is designed to generate one constant current output from a wide range AC input. The size and performance of these products make them the ideal choice for LED

More information

AN1200.04. Application Note: FCC Regulations for ISM Band Devices: 902-928 MHz. FCC Regulations for ISM Band Devices: 902-928 MHz

AN1200.04. Application Note: FCC Regulations for ISM Band Devices: 902-928 MHz. FCC Regulations for ISM Band Devices: 902-928 MHz AN1200.04 Application Note: FCC Regulations for ISM Band Devices: Copyright Semtech 2006 1 of 15 www.semtech.com 1 Table of Contents 1 Table of Contents...2 1.1 Index of Figures...2 1.2 Index of Tables...2

More information

认 证 之 家 http://www.ait0769.com

认 证 之 家 http://www.ait0769.com 认 证 之 家 http://www.ait0769.com EUROPEAN STANDARD EN 55022 NORME EUROPÉENNE EUROPÄISCHE NORM September 2006 ICS 33.100.10 Supersedes EN 55022:1998 + A1:2000 + A2:2003 English version Information technology

More information

AN96-07. Surging Ideas TVS Diode Application Note PROTECTION PRODUCTS. TRANSIENT IMMUNITY STANDARDS: IEC 61000-4-x

AN96-07. Surging Ideas TVS Diode Application Note PROTECTION PRODUCTS. TRANSIENT IMMUNITY STANDARDS: IEC 61000-4-x TRANSIENT IMMUNITY STANDARDS: IEC 61000-4-x On January 1, 1996, exports into Europe began facing some tough transient immunity standards. The International Electrotechnical Commission (IEC), a worldwide

More information

Rack mounted telephone- and leased line modem for industrial applications

Rack mounted telephone- and leased line modem for industrial applications Rack mounted telephone- and leased line modem for industrial applications TR-6 Rack modem for industrial PSTNand /-wire leased line applications The TR-6 is an analogue V. 9 -rack PSTN modem as well as

More information

AN3353 Application note

AN3353 Application note Application note IEC 61000-4-2 standard testing Introduction This Application note is addressed to technical engineers and designers to explain how STMicroelectronics protection devices are tested according

More information

Technical Datasheet Scalar Network Analyzer Model 8003-10 MHz to 40 GHz

Technical Datasheet Scalar Network Analyzer Model 8003-10 MHz to 40 GHz Technical Datasheet Scalar Network Analyzer Model 8003-10 MHz to 40 GHz The Giga-tronics Model 8003 Precision Scalar Network Analyzer combines a 90 db wide dynamic range with the accuracy and linearity

More information

Pre-Compliance Test Method for Radiated Emissions of Automotive Components Using Scattering Parameter Transfer Functions

Pre-Compliance Test Method for Radiated Emissions of Automotive Components Using Scattering Parameter Transfer Functions PreCompliance Test Method for Radiated Emissions of Automotive Components Using Scattering Parameter Transfer Functions D. Schneider 1*, S. Tenbohlen 1, W. Köhler 1 1 Institute of Power Transmission and

More information

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact Data sheet Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact The CT-AHD.12 is an electronic time relay with OFF-delay. It is from the CT-D range. With their MDRC profile and a width of only

More information

RF data receiver super-reactive ASK modulation, low cost and low consumption ideal for Microchip HCS KEELOQ decoder/encoder family. 0.

RF data receiver super-reactive ASK modulation, low cost and low consumption ideal for Microchip HCS KEELOQ decoder/encoder family. 0. Receiver AC-RX2/CS RF data receiver super-reactive ASK modulation, low cost and low consumption ideal for Microchip HCS KEELOQ decoder/encoder family. Pin-out 38.1 3 Component Side 1 2 3 7 11 13 14 15

More information

Evaluating Cell Phone and Personal Communications Equipment and their EMC Effects on Automotive Audio and In-Cabin Modules

Evaluating Cell Phone and Personal Communications Equipment and their EMC Effects on Automotive Audio and In-Cabin Modules Evaluating Cell Phone and Personal Communications Equipment and their EMC Effects on Automotive Audio and In-Cabin Modules Craig W. Fanning Elite Electronic Engineering, Inc. 1516 Centre Circle Downers

More information

RADIO TEST REPORT. EN 300 440-2 SRD radio equipment to be used in the 1 GHz to 40 GHz frequency range. DAkkS - Registration number : D-PL-12092-01-01

RADIO TEST REPORT. EN 300 440-2 SRD radio equipment to be used in the 1 GHz to 40 GHz frequency range. DAkkS - Registration number : D-PL-12092-01-01 RADIO TEST REPORT SRD radio equipment to be used in the 1 GHz to 40 GHz frequency range Report Reference No.... : G0M-1206-2043-TEU440G-V01 Testing Laboratory... : Eurofins Product Service GmbH Address...

More information

30 In Compliance October 2014 www.incompliancemag.com

30 In Compliance October 2014 www.incompliancemag.com 30 In Compliance October 2014 www.incompliancemag.com Medical Devices in a Wireless World BY IVAYLO TANKOV While wireless technology is now an integral component of a wide variety of manufactured products,

More information

Report No. 106262R-RFCEP76V01-A. Test Report. Model No. MS-AE12, AE2420 3D, MS-AE31 3D, MS-AE31, AE2420. Date of Receipt June 15, 2010

Report No. 106262R-RFCEP76V01-A. Test Report. Model No. MS-AE12, AE2420 3D, MS-AE31 3D, MS-AE31, AE2420. Date of Receipt June 15, 2010 Test Report Product Name All in one PC Model No. MS-AE12, AE2420 3D, MS-AE31 3D, MS-AE31, AE2420 Applicant MICRO-STAR INT'L Co., LTD. Address No. 69, Li-De St., Jung-He City, Taipei Hsien, Taiwan, R.O.C.

More information

Current Probes, More Useful Than You Think

Current Probes, More Useful Than You Think Current Probes, More Useful Than You Think Training and design help in most areas of Electrical Engineering Copyright 1998 Institute of Electrical and Electronics Engineers. Reprinted from the IEEE 1998

More information

APSYN420A/B Specification 1.24. 0.65-20.0 GHz Low Phase Noise Synthesizer

APSYN420A/B Specification 1.24. 0.65-20.0 GHz Low Phase Noise Synthesizer APSYN420A/B Specification 1.24 0.65-20.0 GHz Low Phase Noise Synthesizer 1 Introduction The APSYN420 is a wideband low phase-noise synthesizer operating from 0.65 to 20 GHz. The nominal output power is

More information

Power-monitoring unit PowerLogic System. Technical data sheet. Power Meter Series 800

Power-monitoring unit PowerLogic System. Technical data sheet. Power Meter Series 800 Power-monitoring unit PowerLogic System Technical data sheet 2003 Power Meter Series 800 Function and characteristics PB100313 The PowerLogic Power Meter Series 800 offers all the high-performance measurement

More information

Agilent N8973A, N8974A, N8975A NFA Series Noise Figure Analyzers. Data Sheet

Agilent N8973A, N8974A, N8975A NFA Series Noise Figure Analyzers. Data Sheet Agilent N8973A, N8974A, N8975A NFA Series Noise Figure Analyzers Data Sheet Specifications Specifications are only valid for the stated operating frequency, and apply over 0 C to +55 C unless otherwise

More information

Verizon NEBS TM Compliance: HVAC Systems NEBS Requirements Verizon Technical Purchasing Requirements VZ.TPR.9808 Issue 1, April 2014

Verizon NEBS TM Compliance: HVAC Systems NEBS Requirements Verizon Technical Purchasing Requirements VZ.TPR.9808 Issue 1, April 2014 Verizon NEBS TM Compliance: HVAC Systems NEBS Requirements Verizon Technical Purchasing Requirements VZ.TPR.9808 Issue 1, April 2014 CHANGE CONTROL RECORD: Version Date Action* Reason for Revision 1 4/14/2014

More information

ANSI Watthour Meter Testing & Certification Programs

ANSI Watthour Meter Testing & Certification Programs ANSI Watthour Meter Testing & Certification Programs By Jim Reed Manager, Meter Accuracy Lab and Manasi Bhandiwad Manager, EMC Lab Laboratories, Inc. First in Certification Accreditations and Recognitions

More information

Low-cost EMI Pre-compliance Testing Using a Spectrum Analyzer

Low-cost EMI Pre-compliance Testing Using a Spectrum Analyzer Low-cost EMI Pre-compliance Testing Using a Spectrum Analyzer Application Note EMI regulations are in place throughout the world to provide improved reliability and safety for users of electrical and electronic

More information

DUAL%CHANNEL BROADBAND%LINEAR%AMPLIFIER Model&A800D

DUAL%CHANNEL BROADBAND%LINEAR%AMPLIFIER Model&A800D ELECTRONICS AB DUAL%CHANNEL BROADBAND%LINEAR%AMPLIFIER Model&A800D & HIGH&VOLTAGE& FIXED&GAIN& BROADBAND & 800Vpp&60mA& 100x& DC&to&ca&200&kHz & LOW&OUTPUT&IMPEDANCE& HIGH&SLEW&RATE &

More information

for Communication Systems Protection EMI CD-ROM INCLUDED

for Communication Systems Protection EMI CD-ROM INCLUDED Krešimir Malarić EMI Protection for Communication Systems CD-ROM INCLUDED Contents Preface xiii CHAPTER 1 Communications Systems 1 1.1 Components of Communications Systems 1 1.2 Transmitter Systems 2 1.2.1

More information

Harmonics and Noise in Photovoltaic (PV) Inverter and the Mitigation Strategies

Harmonics and Noise in Photovoltaic (PV) Inverter and the Mitigation Strategies Soonwook Hong, Ph. D. Michael Zuercher Martinson Harmonics and Noise in Photovoltaic (PV) Inverter and the Mitigation Strategies 1. Introduction PV inverters use semiconductor devices to transform the

More information

BLACK BOX. T1/E1 Link Extenders OCTOBER 2007 MT195A-T1 MT196A-E1

BLACK BOX. T1/E1 Link Extenders OCTOBER 2007 MT195A-T1 MT196A-E1 BLACK BOX NETWORK SERVICES OCTOBER 2007 MT195A-T1 MT196A-E1 T1/E1 Link Extenders Important This is a Class A device and is intended for use in a light industrial environment. It is not intended nor approved

More information

Test result: SHENZHEN TIMEWAY TECHNOLOGY CONSULTING CO LTD. ISO/IEC17025Accredited Lab. Report No: FCC 1106180 File reference No: 2011-07-18

Test result: SHENZHEN TIMEWAY TECHNOLOGY CONSULTING CO LTD. ISO/IEC17025Accredited Lab. Report No: FCC 1106180 File reference No: 2011-07-18 Report No: FCC 1106180 File reference No: 2011-07-18 ISO/IEC17025Accredited Lab. Applicant: FUJIAN NAN AN BAOFENG ELECTRONICS CO., LTD Product: Model No: Trademark: Two Way Radio UV-3R BAOFENG Test Standards:

More information

DDX 7000 & 8003. Digital Partial Discharge Detectors FEATURES APPLICATIONS

DDX 7000 & 8003. Digital Partial Discharge Detectors FEATURES APPLICATIONS DDX 7000 & 8003 Digital Partial Discharge Detectors The HAEFELY HIPOTRONICS DDX Digital Partial Discharge Detector offers the high accuracy and flexibility of digital technology, plus the real-time display

More information

White Paper: Electrical Ground Rules

White Paper: Electrical Ground Rules Acromag, Incorporated 30765 S Wixom Rd, Wixom, MI 48393 USA Tel: 248-295-0880 Fax: 248-624-9234 www.acromag.com White Paper: Electrical Ground Rules Best Practices for Grounding Your Electrical Equipment

More information

Chrome DIN Rail Power Supply 24V 91.2W 1 Phase (Class II & NEC Class 2) / DRC-24V100W1AZ

Chrome DIN Rail Power Supply 24V 91.2W 1 Phase (Class II & NEC Class 2) / DRC-24V100W1AZ Highlights & Features Protection Class II, Double Isolation (No Earth connection is required) Universal AC input voltage without power de-rating Efficiency > 87.0% @ 115Vac, > 89.0% @ 230Vac NEC Class

More information

NMI M 6-2 Electricity Meters. Part 2: Test Report Format

NMI M 6-2 Electricity Meters. Part 2: Test Report Format NMI M 6-2 Electricity Meters Part 2: Test Report Format Commonwealth of Australia 2010 First edition September 2010 National Measurement Institute Bradfield Road, Lindfield, NSW 2070 PO Box 264, Lindfield,

More information

APPLICATION NOTE How to Deal with Electrical Noise and Interference in the Measuring Chain using a NEXUS

APPLICATION NOTE How to Deal with Electrical Noise and Interference in the Measuring Chain using a NEXUS APPLICATION NOTE How to Deal with Electrical Noise and Interference in the Measuring Chain using a NEXUS Conditioning Amplifier by Claus Lindahl and Bernard Ginn, Brüel&Kjær When making vibration measurements,

More information

Workbench EMC Measurements by Henry W. Ott Henry Ott Consultants www.hottconsultants.com

Workbench EMC Measurements by Henry W. Ott Henry Ott Consultants www.hottconsultants.com Workbench EMC Measurements by Henry W. Ott Henry Ott Consultants www.hottconsultants.com Workbench EMC measurements are simple, inexpensive precompliance tests that a product designer can perform early

More information

Coupling/Decoupling Networks (CDN)

Coupling/Decoupling Networks (CDN) Coupling/Decoupling Networks (CDN) For immunity testing according to IEC / EN 61000-4-6 Immunity testing CDNs are the preferred coupling and decoupling devices, for reasons of test reproducibility and

More information

CE EMC Test Report. : Texas Instruments Incorporated : WiFi and Bluetooth Evaluation Board

CE EMC Test Report. : Texas Instruments Incorporated : WiFi and Bluetooth Evaluation Board CE EMC Test Report APPLICANT EQUIPMENT BRAND NAME MODEL NAME : Texas Instruments Incorporated : WiFi and Bluetooth Evaluation Board : Texas Instruments : WL1835MODCOM8B STANDARD : ETSI EN 301 489-1 V1.9.2

More information

BioStation Mifare OC(BSM-OC) NONE. Receipt Date 21-Feb-08 Receipt Number. Issued Date 18-Mar-08 Tested Date

BioStation Mifare OC(BSM-OC) NONE. Receipt Date 21-Feb-08 Receipt Number. Issued Date 18-Mar-08 Tested Date Test Report for CE Report Number Applicant ESTCE0803-003 Company Name Address Product type Suprema Inc. 16F Parkview Office Tower, Jeongja-dong, Bundang-gu,Seongnam, Gyeonggi, 463-863 Korea FINGERPRINT

More information

1+1 PROTECTION WITHOUT RELAYS USING IDT82V2044/48/48L & IDT82V2054/58/58L HITLESS PROTECTION SWITCHING

1+1 PROTECTION WITHOUT RELAYS USING IDT82V2044/48/48L & IDT82V2054/58/58L HITLESS PROTECTION SWITCHING 1+1 PROTECTION WITHOUT RELAYS USING IDT82V2044/48/48L & IDT82V2054/58/58L APPLICATION NOTE AN-357 1.0 INTRODUCTION In today's highly competitive market, high quality of service, QOS, and reliability is

More information

Chrome DIN Rail Power Supply 24V 30W 1 Phase (Class II & NEC Class 2) / DRC-24V30W1AZ

Chrome DIN Rail Power Supply 24V 30W 1 Phase (Class II & NEC Class 2) / DRC-24V30W1AZ Highlights & Features Protection Class II, Double Isolation (No Earth connection is required) Universal AC input voltage without power de-rating Efficiency > 87.0% @ 115Vac & 230Vac NEC Class 2 / Limited

More information

COUPLING / DECOUPLING NETWORK (CDN) FOR UNSCREENED BALANCED PAIRS

COUPLING / DECOUPLING NETWORK (CDN) FOR UNSCREENED BALANCED PAIRS IEC / EN 61000-4-6 specifies the design and performance of a range of coupling / decoupling networks (CDNs). Each CDN is specific to the type of cable and the intended signal carried on the cable. Teseq

More information

Energy Management Energy Meter Type EM23 DIN

Energy Management Energy Meter Type EM23 DIN Energy Management Energy Meter Type EM23 DIN Class 1 (kwh) according to EN62053-21 Class B (kwh) according to EN50470-3 Class 2 (kvarh) according to EN62053-23 Accuracy ±0.5 RDG (current/voltage) Energy

More information

Applications in EMC testing. Outline. Antennas for EMC Testing. Terminology

Applications in EMC testing. Outline. Antennas for EMC Testing. Terminology Antennas for EMC Testing Zhong Chen ETS-Lindgren 1301 Arrow Point Drive Cedar Park, TX 78613 Zhong.Chen@ets-lindgren.com Outline EMC Terms and Definitions Typical EMC Antennas Calibration of EMC Antennas

More information

Network Analyzer for Low-, Medium- and High-Voltage Networks

Network Analyzer for Low-, Medium- and High-Voltage Networks Technical data Network nalyzer for Low-, Medium- and High-Voltage Networks Model PQ-Box 100 1 Fault detection 1 Evaluation of voltage quality according to EN50160 and IEC61000-2-2 (2-4) 1 Fault recorder

More information

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features: Application : RISH Master 3490 DS measures important electrical parameters of Utility (in normal mode) & Generators (in Power back up) in three phase and single phase Network & replaces the multiple analog

More information

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector Product datasheet Characteristics TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector Main Range of product Product or component type Range compatibility Enclosure material Bus

More information

EMC for test engineers by. Laplace Instruments Ltd. An introduction to the world of EMC compliance testing for engineers new to the topic.

EMC for test engineers by. Laplace Instruments Ltd. An introduction to the world of EMC compliance testing for engineers new to the topic. EMC for test engineers by An introduction to the world of EMC compliance testing for engineers new to the topic. Index: Introduction Page 3 The EU Directive Page 3 The EMC Standards. Page 3 Compliance

More information

Application Note: Spread Spectrum Oscillators Reduce EMI for High Speed Digital Systems

Application Note: Spread Spectrum Oscillators Reduce EMI for High Speed Digital Systems Application Note: Spread Spectrum Oscillators Reduce EMI for High Speed Digital Systems Introduction to Electro-magnetic Interference Design engineers seek to minimize harmful interference between components,

More information