SHARKY 775 COMPACT ENERGY METER ULTRASONIC



Similar documents
SHARKY 775 COMPACT ENERGY METER ULTRASONIC

CORONA E / FLYPPER ELECTRONIC METER MULTI-JET

HYDRUS ULTRASONIC METER

SONOMETER TM 1000 Ultrasonic compact heat meter

AMTRON E-30 Compact heat and cooling meter

How To Use A Corona Mdi 110

SHARKY 775 Ultrasonic Compact Energy Meter. Installation and User Guide

The multi-functional integrator Supercal 531

A project to optimise quality and energy efficiency must include metering

Instructions for assembly and use MULTICAL 601

MULTICAL 602 DATA SHEET

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

IFC 070 Technical Datasheet

MOUNTING AND OPERATING INSTRUCTIONS

Heat meters Cooling meters

Electro-Magnetic Flowmeters COPA-XT 2-Wire DT43

Typical Aluminum GFM Mass Flow Meter

SENSORS. Miniature Sensors - S3Z. Advanced line of miniature Asian style of photoelectric sensors mm background suppression

An internal gyroscope minimizes the influence of dynamic linear acceleration on slope sensor readings.

AVL FUEL MASS FLOW METER & FUEL TEMPERATURE CONTROL

Heating, air-conditioning, cooling

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

Measurement. SITRANS F US Inline. Transmitter FUS080/FUE080 4/219

OZW30. Central Unit SYNERGYR

Intelligent chart recorder for compressed air and gases. Measurement - control - indication - alarm - recording - evaluation

Technical Specifications: The specifications represent a particular hardware platform. Application-specific software is provided.

Preset Counter signo 721

Electronic Control Devices The European Product Catalogue 2007

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

LLB-OCMFM 2000 PORTABLE DOPPLER AREA-VELOCITY FLOWMETER

BM SERIES WAVE COMPACT 6.3 GHZ CW SERIES PULSE RADAR LEVEL INSTRUMENTS (6.3 GHz)

SWITCH! DESCRIPTION. ENVIRONMENTAL SPECIFICATIONS Operating Temperature: 0 C to +40 C SPECIFICATION SHEET:

Programmable Terminal. NPSeries. Easy Setup with the Low-cost, Compact NP Series

Battery Powered Thermal Mass Flow Meters for Gases

Polyphase kwh Electricity Meter

UMEC International Corporation

Installation manual. Generator Paralleling Controller GPC multi-line C

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

Temperature & Humidity SMS Alert Controller

Series DFMT Digital Paddlewheel Flowmeter

Static energy meters

Visions become real. Temperature control and cooling systems. The innovative and reliable solution

User Manual V SDM220MODBUS. Single-Phase Two Module DIN rail Meters

Position Transducers with Restoring Spring 10, 25, 50, 75, 100 mm TR, TRS Series

How To Use A Multi-Line Calculator With A Power Supply And Power Supply (Kamstrup)

DREXELBROOK. USonic-R Series. Ultrasonic Level Measurement System. User Friendly

OEM Pressure Transmitters for heavy-duty applications, Type MBS 1200 and MBS 1250

KACO-monitoring. onlinecomponents.com. Integrated monitoring available. Monitor up to 32 inverters per prolog. Reliable and accurate data

SITRANS F flowmeters SITRANS FUS080. Flowmeter FUE380 with approval. 4/202 Siemens FI Overview

CONTOIL DFM 8EDM. Table of contents. Mounting and operating instructions

Certified according to DIN EN ISO 9001 Technical Datasheet C-Flow Coriolis Mass Flow Meter

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

Nardalert S3 Non-Ionizing Radiation Monitor

Battery Powered Thermal Mass Flow Meters for Gases

red-y smart series product information Thermal Mass Flow Meters and Controllers for Gases

NC-12 Modbus Application

O C M III. Open Channel Flow Monitor

How To Use A Flowmeter

PRO-CLEAN. Technical Description. Specifications. Space-saving design with minimum heat loss (melamine resin insulation)

4-Channel Thermometer / Datalogger

GeoMax GNSS Zenith10 & Zenith20 Series

Turbine Flow Sensor Series VTR

Technical data. General specifications. Indicators/operating means. Electrical specifications Operating voltage U B Power consumption P 0 Interface

Temperature sensor with integrated transmitter for industrial applications, MBT 3560

Quick Connect. quick - simple - efficient.

Energy Management Energy Meter Type EM23 DIN

Applications. diris_826_a_1_gb_cat

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument D

MULTICAL 21 DATA SHEET. Electronic ultrasonic cold and hot water meter

Product Data. Thermal Comfort Data Logger Type Including Application Software Type 7301

Operating Manual UWAPS-TINY Series

SITRANS F flowmeters SITRANS FUS080. SITRANS FUS380/FUE380/SONOCAL /179. flow sensor pipe, 4 transducers/transducer cables and a transmitter

EGSTON Standard E2xFxWx 12W

14.5GHZ 2.2KW CW GENERATOR. GKP 22KP 14.5GHz WR62 3x400V

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

MPR-Systems. Mini Power Racks 1200 W W

Electromagnetic Flow Meter

THERMAL ENERGY METER MC 108/ET

Non-invasive CLAMP-ON ultrasonic flowmeter for liquids

USB-500 Series Stand-Alone, Low-Cost Data Loggers

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION

MLC TM Maximum Productivity and Versatility for Control without Compromise!

Telephone- and leased line modem for industrial applications TD-36

Top Microsystems Proprietary Specification P/N: W090015HK-XP RB V.A0 SPECIFICATION

Ensto Chago Master EVM300 and EVM500 Operational description

QFP910. Water detector. Building Technologies. CE1N2732en. Synco living

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

Emergency lighting units EM powerled

MAJORSINE Power Inverter

THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES

Thyristor-controlled power supplies and battery chargers

DS 600. A contact free flux gate based current measurement sensor 600A rms

T Substation Maintenance and Commissioning Test Equipment

Certified according to DIN EN ISO 9001 Technical Datasheet KVO Series Vortex Flow Meter

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

U LED modules, converters and systems GENERAL ILLUMINATION. Umodule SPOT P330-2 umodule SPOT PHASED OUT NTC

Description. Dimensions. Features. precision works better

siemens.com/mobility Radar detectors of the Heimdall family High detection rate, easy installation

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

U LED modules, converters and systems GENERAL ILLUMINATION. Umodule SPOT P340-2 umodule SPOT PHASED OUT NTC

Transcription:

APPLICATION The ultrasonic compact energy meter can be used for measuring the energy consumption in heating / cooling application for billing purposes. FEATURES 4 Approval for ultrasonic meter with dynamic range of 1:250 (qi:q p) in class 2 4 Improved power consumption --> longer battery lifetime 4 Approved according MID in class 2 and 3 and PTB K 7.2 (cooling) 4 High long term stability, tested and verified at independent AGFW test 4 Insensitive against dirt 4 Versatile possibility of power supply 4 Integrated Radio, Real Data or Open Metering Standard (868 or 434 MHz) 4 Inidividual remote reading (AMR) with add on modules Plug & Play 4 Extensive readable data memory 4 2 communication ports (e. g. M-Bus + Radio) 4 Significantly improved radio performance

GENERAL Application Heating - cooling - heating/cooling Approval MID (DE-10-MI004-PTB013) and PTB K7.2 (cooling) Mounting position flow sensor Any position Protection class flow sensor Heating: IP 54; cooling, heating/cooling: IP 68 Battery supply 3.6 VDC - A-cell max. 11 years lifetime; 3.6 VDC- D-cell 16 years lifetime Mains supply 24 VAC; 230 VAC Temperature sensor type Pt 100 or Pt 500 with 2-wire leads; Ø 5.2 / 6 mm or direct sensor Cable length of temperature sensor Pt 100: 2 m; Pt 500: 2 / 3 1 / 5 m Volume measuring cycle With mains unit: ⅛ s; with A-cell battery: 2 s; with D-cell battery: 1 s Test possibilities via display, optical test pulses, test output or via NOWA software 1 : Only for meters with PTB K 7.2 approval CALCULATOR - BASIC FEATURES Ambient class Class E1 + M1 Ambient temperature C 5... 55 Ambient storage temperature C -25... +70 Protection class IP 54 Communication 2 communication slots (e. g. M-Bus + M-Bus; 2 primary adresses, 1 secondary adress) Integrated Radio Optional Interfaces standard Optical ZVEI interface Interfaces optional Temperature range heatmeter C 5... 130 / 150 Temperature range cooling meter and heating/cooling meter C 5... 105 2 Slots for modules with M-Bus, L-Bus, RS232, RS485, pulse output, pulse input, combined pulse in-/output or analogue output Extensive readable data memory Monthly memory 1 ; historical LOG memory; event memory 1 : Programmable storage interval (daily, weekly, monthly,...) CALCULATOR - INTEGRATED RADIO Frequency band 868 or 434 MHz Type of radio telegram Real Data or Open Metering Standard (OMS) Transmission data updating Online - no time delay between value measurement and data transmission Data transmission Unidirectional Sending interval 12... 20 s; depending on length of telegram (duty cycle) 15.10.2010 2

DISPLAY Display indication LCD, 8-digit Units MWh - kwh - GJ - Gcal - MBtu - gal - GPM - C - F - m³ - m³/h Total values 99,999,999-9,999,999.9-999,999.99-99,999.999 Values displayed Energy - Power - Volume - Flow rate - Temperature and more INTERFACES Optical ZVEI interface, for communication and testing, M-Bus protocol. M-Bus L-Bus RS232 RS485 Pulse output Pulse input Combined pulse in-/output Analogue output Configurable telegram, according to EN13757-3, data reading and parametrization are via two wires with polarity reversal protection, auto baud detect (300 and 2400 baud), 2 M-Bus with 2 primary adresses. Adapter for external radio module, configurable telegram, according to EN13757-3, data reading and parametrization are via two wires with polarity reversal protection. Serial interface for communication with external devices, a special data cable is required, M- Bus protocol, 300 and 2400 baud. Serial interface for communication with external devices, power supply with 12V ± 5V, M-Bus protocol, 2400 baud. Module with 2 Open Collector pulse outputs (potential-free), output 1: 4 Hz (pulse width 125 ms), pulse or static conditions (e.g. errors), output 2: 100 Hz (pulse width 5 ms), ratio: pulse duration / pulse break ~ 1:1, configurable via IZAR@SET software. Module with 2 pulse inputs, max. 20Hz, configurable via IZAR@SET software, data can be transferred remotely. Module with 2 pulse inputs and 1 pulse output, configurable via IZAR@SET software, needed for leak detection. Module for 4... 20 ma with 2 programmable passive outputs, programmable value in case of error. TEMPERATURE INPUT Sensor current ma Pt 100 peak < 8; rms < 0.015, Pt 500 peak < 2; rms < 0.012 Measuring cycle T s With mains unit: 2 s; with A-cell battery: 16 s; with D-cell battery: 4 s Starting temperature difference ΔΘ K 0.125 Min. temperature difference ΔΘ min K 3 Max. temperature difference ΔΘ max K 177 Absolute temperature measuring range Θ C 1... 180 15.10.2010 3

TECHNICAL DATA FLOW SENSOR Nominal flow rate qp m 3 /h 0.6 0.6 0.6 1.5 1.5 1.5 Nominal diameter DN mm 15 20 20 15 20 20 Overall length L mm 110 130 190 110 130 190 Starting flow rate l/h 1 1 1 2.5 2.5 2.5 Minimum flow rate q i l/h 6 6 6 6 6 6 Maximum flow rate q s m 3 /h 1.2 1.2 1.2 3 3 3 Overload flow rate m 3 /h 2.5 2.5 2.5 4.6 4.6 4.6 Operating pressure PN bar 16 1 16 1 16 1 16 1 16 1 16 1 Pressure loss at q p Δp mbar 85 85 85 75 75 75 Temp. range heating C 5... 130 5... 130 5... 130 5... 130 5... 130 5... 130 Temp. range cooling C 5... 50 5... 50 5... 50 5... 50 5... 50 5... 50 Temp. range heating/cooling C 5... 105 5... 105 5... 105 5... 105 5... 105 5... 105 Flow resistance coefficient Zeta 21.3 67.5 67.5 4.3 13.6 13.6 Nominal flow rate qp m 3 /h 2.5 2.5 3.5 3.5 6 6 Nominal diameter DN mm 20 20 25 32 25 32 Overall length L mm 130 190 260 260 260 260 Starting flow rate l/h 4 4 7 7 7 7 Minimum flow rate q i l/h 10 10 35 35 24 24 Maximum flow rate q s m 3 /h 5 5 7 7 12 12 Overload flow rate m 3 /h 6.7 6.7 18.4 18.4 18.4 18.4 Operating pressure PN bar 16 1 16 1 16 1 16 1 16 1 16 1 Pressure loss at q p Δp mbar 100 100 44 44 128 128 Temp. range heating C 5... 130 5... 130 5... 150 5... 150 5... 150 5... 150 Temp. range cooling C 5... 50 5... 50 5... 50 5... 50 5... 50 5... 50 Temp. range heating/cooling C 5... 105 5... 105 5... 105 5... 105 5... 105 5... 105 Flow resistance coefficient Zeta 4 4 2.8 7.4 2.8 7.4 Nominal flow rate qp m 3 /h 10 10 15 25 40 60 Nominal diameter DN mm 40 40 50 65 80 100 Overall length L mm 200 300 270 300 300 360 Starting flow rate l/h 20 20 40 50 80 120 Minimum flow rate q i l/h 40 3 /100 40 3 /100 60 3 /150 100 3 /250 160 240 3 /600 4 /1200 5 Maximum flow rate q s m 3 /h 20 20 30 50 80 120 Overload flow rate m 3 /h 24 24 36 60 90 132 Operating pressure PN bar 16 1 16 1 25 2 25 2 25 2 16/25 2 Pressure loss at q p Δp mbar 95 95 80 75 80 75 Temp. range heating C 5... 150 5... 150 5... 150 5... 150 5... 150 5... 150 Temp. range cooling C 5... 50 5... 50 5... 50 5... 50 5... 50 5... 50 Temp. range heating/cooling C 5... 105 5... 105 5... 105 5... 105 5... 105 5... 105 Flow resistance coefficient Zeta 3.8 3.8 3.5 3.4 3.4 3.8 1 : Also available in PN 25 bar 2 : Also available in PN 40 bar 3 : Only for horizontal installation 4 : Only in rising or falling pipes or tilted installation 5 : Only up side down installation 15.10.2010 4

DIMENSIONS THREAD VERSION Nominal flow rate qp m 3 /h 0.6 0.6 0.6 1.5 1.5 1.5 Nominal diameter DN mm 15 20 20 15 20 20 Overall length L mm 110 130 190 110 130 190 Overall length with coupling L2 mm 190 230 290 190 230 290 Length of calculator L1 mm 150 150 150 150 150 150 Height H mm 14.5 18 18 14.5 18 18 Height H1 mm 82 84 84 82 84 84 Height of calculator H2 mm 54 54 54 54 54 54 Width of calculator B mm 100 100 100 100 100 100 Connection thread on meter Inch G¾B G1B G1B G¾B G1B G1B Connection thread of coupling Inch R½ R¾ R¾ R½ R¾ R¾ Weight kg 0.76 0.85 0.96 0.76 0.85 0.96 Nominal flow rate qp m 3 /h 2.5 2.5 3.5 3.5 6 6 Nominal diameter DN mm 20 20 25 32 25 32 Overall length L mm 130 190 260 260 260 260 Overall length with coupling L2 mm 230 290 380-380 - Length of calculator L1 mm 150 150 150-150 - Height H mm 18 18 23-23 - Height H1 mm 84 84 88.5-88.5 - Height of calculator H2 mm 54 54 54-54 - Width of calculator B mm 100 100 100-100 - Connection thread on meter Inch G1B G1B G1¼B - G1¼B - Connection thread of coupling Inch R¾ R¾ R1 - R1 - Weight kg 0.85 0.96 1.5-1.5 - Nominal flow rate qp m 3 /h 10 10 15 25 40 60 Nominal diameter DN mm 40 40 50 65 80 100 Overall length L mm 200 300 270 300 300 360 Overall length with coupling L2 mm 340 440 - - - - Length of calculator L1 mm 150 150 - - - - Height H mm 33 33 - - - - Height H1 mm 94 94 - - - - Height of calculator H2 mm 54 54 - - - - Width of calculator B mm 100 100 - - - - Connection thread on meter Inch G2B G2B - - - - Connection thread of coupling Inch R1½ R1½ - - - - Weight kg 2.4 3 - - - - 15.10.2010 5

DIMENSIONS FLANGE VERSION Nominal flow rate qp m 3 /h 0.6 0.6 0.6 1.5 1.5 1.5 Nominal diameter DN mm 15 20 20 15 20 20 Overall length L mm 110 130 190 110 130 190 Length of calculator L1 mm - - 150 - - 150 Height H mm - - 47.5 - - 47.5 Height H1 mm - - 84 - - 84 Height of calculator H2 mm - - 54 - - 54 Width of calculator B mm - - 100 - - 100 Flange dimension F mm - - 95 - - 95 Flange diameter D mm - - 105 - - 105 Hole circle diameter K mm - - 75 - - 75 Screwhole diameter D1 mm - - 14 - - 14 Number of screwholes pcs - - 4 - - 4 Weight kg - - 2.75 - - 2.75 Nominal flow rate qp m 3 /h 2.5 2.5 3.5 3.5 6 6 Nominal diameter DN mm 20 20 25 32 25 32 Overall length L mm 130 190 260 260 260 260 Length of calculator L1 mm - 150 150 150 150 150 Height H mm - 47.5 50 62.5 50 62.5 Height H1 mm - 84 88.5 88.5 88.5 88.5 Height of calculator H2 mm - 54 54 54 54 54 Width of calculator B mm - 100 100 100 100 100 Flange dimension F mm - 95 100 125 100 125 Flange diameter D mm - 105 114 139 114 139 Hole circle diameter K mm - 75 85 100 85 100 Screwhole diameter D1 mm - 14 14 18 14 18 Number of screwholes pcs - 4 4 4 4 4 Weight kg - 2.75 3.5 4.8 3.5 4.8 Nominal flow rate qp m 3 /h 10 10 15 25 40 60 Nominal diameter DN mm 40 40 50 65 80 100 Overall length L mm 200 300 270 300 300 360 Length of calculator L1 mm - 150 150 150 150 150 Height H mm - 69 73.5 85 92.5 108 Height H1 mm - 94 99 106.5 114 119 Height of calculator H2 mm - 54 54 54 54 54 Width of calculator B mm - 100 100 100 100 100 Flange dimension F mm - 138 147 170 185 216 Flange diameter D mm - 148 163 184 200 235 Hole circle diameter K mm - 110 125 145 160 180 1 /190 Screwhole diameter D1 mm - 18 18 18 19 19 1 /22 Number of screwholes pcs - 4 4 8 8 8 Weight kg - 6.8 7.6 9.6 11.2 17 1 : Values for PN16 housing 15.10.2010 6

PRESSURE LOSS GRAPH / TYPICAL ERROR GRAPH Pressure loss graph Typical error graph 15.10.2010 7