PowerWorld Transmission Line Parameter Calculator



Similar documents
PowerWorld Transmission Line Parameter Calculator Version 2

Estimating Line-Flow Limits

Modeling of Transmission Lines

Radial Distribution Test Feeders

Voltage Loss Formula s

1 = 13.8 kv. 1 = 69 kv

EEL303: Power Engineering I - Tutorial 4

EARTHING SYSTEM CALCULATION

Transmission Lines. Smith Chart

6 ELECTRICAL PARAMETERS

Critical thin-film processes such as deposition and etching take place in a vacuum

Basic Electrical Technology Dr. L. Umanand Department of Electrical Engineering Indian Institute of Science, Bangalore. Lecture phase System 4

Measurement of Capacitance

Bill is the author of 15 papers and lectures on transmission lines and other power system topics.

Times Microwave Systems Hermetically Sealed Assemblies

Voltage Drop. Voltage Drop 1

Power Technology Issue 104. Modeling of Two-Winding Voltage Regulating Transformers for Positive Sequence Load Flow Analysis in PSS E

Static Analysis of Power Systems. Lennart Söder and Mehrdad Ghandhari

High Voltage Transient Analysis

Fault Analysis I PowerWorld Corporation

EDS KV TRIPLEX CABLE

Standex-Meder Electronics. Custom Engineered Solutions for Tomorrow

Simple Methods for Calculating Short Circuit Current Without a Computer By Dennis McKeown, PE GE Senior System Application Engineer

Comparison of Power Título Transmission Line Models with Finite Elements

Digital Energy ITI. Instrument Transformer Basic Technical Information and Application

DIMENSIONING OF CURRENT TRANSFORMERS FOR PROTECTON APPLICATION

ACADEMIC INTERGRITY POLICY

DRIVING LOOOONG CABLES

Three phase circuits

Introduction to PowerWorld Simulator: Interface and Common Tools

Coupled Inductors. Introducing Coupled Inductors

Electrician s Math and Basic Electrical Formulas

Short Circuit Current Calculations

RLC Series Resonance

ε: Voltage output of Signal Generator (also called the Source voltage or Applied

LAB1 INTRODUCTION TO PSS/E EE 461 Power Systems Colorado State University

Experiment #11: LRC Circuit (Power Amplifier, Voltage Sensor)

Voltage Drop (Single-Phase)

Trigonometry for AC circuits

Understanding Power Factor and How it Affects Your Electric Bill. Presented by Scott Peele PE

Selecting Current Transformers Part 1 By Darrell G. Broussard, P.E.

Lecture Notes ELE A6

CHAPTER 2 EXAMPLES AND TABLES

Inductors in AC Circuits

1. Metric system- developed in Europe (France) in 1700's, offered as an alternative to the British or English system of measurement.

Power Technology Issue 106. Modeling of Three-Winding Voltage Regulating Transformers for Positive Sequence Load Flow Analysis in PSS E

Physical Quantities, Symbols and Units

MV CABLE TYPE C

Chapter 24. Three-Phase Voltage Generation

Simulation of Cable Overloading Problem on a University Distribution System

Basic Laws Circuit Theorems Methods of Network Analysis Non-Linear Devices and Simulation Models

Cables, Cable Laying & Accessories Manual

Objectives 200 CHAPTER 4 RESISTANCE

How To Understand And Understand The Theory Of Electricity

Application Note. So You Need to Measure Some Inductors?

ECE 431. Experiment #1. Three-Phase ac Measurements. PERFORMED: 26 January 2005 WRITTEN: 28 January Jason Wells

Ohm's Law and Circuits

Simulation of Ungrounded Shipboard Power Systems in PSpice

Wireless Power Transfer System Design. Julius Saitz ANSYS

SYNCHRONOUS MACHINES

Induction Motor Theory

Electrical Considerations for HVDC Transmission Lines. Joe Mooney, PE

Fundamentals of Power

Tutorials Drawing a 555 timer circuit

Cable Tray Selection-

Direction of current flow through conductor. Fig. 1 Magnetic field generated by current flow

45. The peak value of an alternating current in a 1500-W device is 5.4 A. What is the rms voltage across?

PROPER SELECTION OF CONTROL CIRCUIT TRANSFORMERS WHITE PAPER BULLETIN 1497, 1497A, AND 1497B

Copper wire figures. AWG Table

EXTENDING THE LIFE OF POWER FACTOR CAPACITORS

Perimeter, Area, and Volume

MATH 110 Landscape Horticulture Worksheet #4

The W5JCK Guide to the Mathematic Equations Required for the Amateur Extra Class Exam

Impedance Matching. Using transformers Using matching networks

Application Note. Troubleshooting Communications

Safety technique. Emergency stop module BO 5988 safemaster

2/20/ Transmission Lines and Waveguides.doc 1/3. and Waveguides. Transmission Line A two conductor structure that can support a TEM wave.

Mining Cable Engineering Handbook. 2nd Edition

Chapter 12: Three Phase Circuits

1 Introduction. 2 Two Phases. J.L. Kirtley Jr.

Quick Connect. quick - simple - efficient.

AC Power. by Prof. Dr. Osman SEVAİOĞLU Electrical and Electronics Engineering Department

Chapter 10. RC Circuits ISU EE. C.Y. Lee

Tallahassee Community College PERIMETER

1 Introduction. 2 The Symmetrical Component Transformation. J.L. Kirtley Jr.

Table of Contents. The Basics of Electricity 2. Using a Digital Multimeter 4. Testing Voltage 8. Testing Current 10. Testing Resistance 12

5. Measurement of a magnetic field

The Critical Length of a Transmission Line

Chapter 11. Inductors ISU EE. C.Y. Lee

Introduction to the Smith Chart for the MSA Sam Wetterlin 10/12/09 Z +

Power measurement in balanced 3 phase circuits and power factor improvement. 1 Power in Single Phase Circuits. Experiment no 1

Power System Simulation for Engineers (PSS/E version 33)

AMFA-27 AMFA-29. Operator s Manual & Installation Instructions. Rev. 2.5

PHYSICAL METHODS, INSTRUMENTS AND MEASUREMENTS - Measurements Of Electrical Quantities - Ján Šaliga MEASUREMENTS OF ELECTRICAL QUANTITIES

(3 )Three Phase Alternating Voltage and Current

Steady-State Power System Security Analysis with PowerWorld Simulator

Gulf Cable & Electrical Ind. Co.

General Calculations. Excerpt from PRYSMIAN S WIRE AND CABLE ENGINEERING GUIDE

Joule Equivalent of Electrical Energy

Transcription:

PowerWorld Transmission Line Parameter Calculator Introduction The PowerWorld Transmission Line Parameter Calculator is a tool designed to compute characteristic line parameters given the type of the conductor and the tower configuration of a three-phase overhead transmission line. The parameters computed are the resistance R, reactance X, susceptance, and conductance G. These values are computed as distributed (per unit of distance), lumped or total (for a specific line distance), and in per-unit. Calculations The following controls are part of the calculations section: Parameters Calculation This section is to enter the necessary data to compute the characteristic line parameters that are shown in the Results panel. Input ata Conductor Type: Tower Configuration: Line Length: Line Length Units: This is the combo box that lists all the conductor types available in the Conductors table. To add, remove or edit a specific conductor and its characteristics, see Conductor Type section below. This combo box lists all the tower configurations available in the Tower Configurations table. To add, remove or edit a specific tower configuration, please go to the Tower Configuration section below. This is the value of the distance of the transmission line. The units are miles when using English system, or kilometers when using the Metric (SI) system. The line length units specify the measurement system to use when entering the line length. The options are English system or Metric (SI) system. The final and intermediate results will also be shown in the system specified here. Page 1 of 13

Power ase: Voltage ase: Impedance ase: Admittance ase: The system voltampere base in MVA. The line-line voltage base in KV. The impedance base in Ohms. This value is automatically computed when the power base and the voltage base are entered or modified. The admittance base in Siemens. It is also automatically computed as the inverse of the impedance base. Final Results When all the input data is entered, the results automatically will be displayed. The values for R, X, and G are shown in three different sections, each section corresponding to istributed, Lumped or Total, and Per Unit values, respectively. The Power Surge Impedance Loading is calculated only for the lumped section. Intermediate Results The intermediate values calculated to compute the R, X,, and G values are displayed here. The computed geometric mean radius and geometric mean distance are shown in the istributed values section. The characteristic impedance and propagation factor are displayed in the Lumped values section. ote: To see the specific calculations used in this program, see the Calculations section, at the end of this document. Ampere to MVA Limit Conversion This section converts the limits of the transmission line from Amperes to MVAs, given the voltage base, and vice versa. Page 2 of 13

Conductor Type This section is used to add, remove, rename, and edit the information related to the conductor types. This can be done in two ways: using the form for an individual conductor type, or using the table for all the conductor types available. Edit y Form Conductors are identified by a unique code word. All the available conductors are listed in the Conductor Code Word combo box. y selecting one conductor, all its properties are displayed in the form. There, the user is able to modify any of those values. After modification of any value, the user has to save the changes by clicking on the button Save before changing tabs, otherwise the changes will be lost. y clicking on ew, a message prompting for a name for a new conductor will be shown. y clicking on Rename, a new name for the current conductor type is required. In order to save the current conductor type with a different name is necessary to click on Save As. Finally, to remove the current conductor the user can do so by clicking on the elete button. Edit y Table In this tab, all the conductor types are shown as records in a table, where every field is a characteristic of the conductor. In order to edit the records in this table, use the atabase button described in the atabase section. While editing the table, the user can not change of tab until changes are posted or discarded. Conductor Properties The available properties of the conductors are the following: Code Word: Area: Aluminum strands: Steel layers: Code name for the type of conductor. The names of bird species are typically used. Code Word has to be unique. The area of aluminum conductor in circular mils. A circular mil is the cross-sectional area of a circular conductor having a diameter of 1 mil. One mil is one thousandth of an inch (0.001 ). umber of aluminum strands. umber of steel strands. Page 3 of 13

Aluminum layers: External diameter: GMR: C Resistance: AC Resistance 25: AC Resistance 50: AC Resistance 75: Inductive Reactance: umber of aluminum layers. Outside diameter of the conductor in inches. Geometric Mean Radius in feet. C resistance of the conductor at 20 C per 1 mile in Ohms. AC resistance of the conductor at 60 Hz and 25 C per 1 mile in Ohms. AC resistance of the conductor at 60 Hz and 50 C per 1 mile in Ohms. AC resistance of the conductor at 60 Hz and 75 C per 1 mile in Ohms. Inductive reactance per conductor at 1 foot spacing at 60 Hz in Ohms/mile. Capacitive Reactance: Capacitive reactance per conductor at 1 foot spacing at 60 Hz in MegaOhms/mile. Page 4 of 13

Tower Configuration This part is used to add, remove, rename, and edit the information related to the tower configurations. This can be done in two ways: using the form for an individual tower configuration, or using the table for all the tower configurations available. Edit y Form Tower configurations are identified by a unique name. All the available tower configurations are listed in the Tower Configuration ame combo box. y selecting one specific tower configuration, all its characteristics are displayed in the form. There, the user can modify any of those characteristics. After modification of any value, the user has to save the changes by clicking on the button Save before changing tabs, otherwise the changes will be lost. y clicking on ew, a message prompting for a name for a new tower configuration will be shown. y clicking on Rename, a new name for the current tower configuration is required. In order to save the current tower configuration with a different name is necessary to click on Save As. Finally, to remove the current tower configuration the user can do so by clicking on the elete button. Edit y Table In this tab, all the tower configurations are shown as records in a table, where every field is a value of the tower configuration. In order to edit the records in this table, use the atabase button described in the atabase section. While editing the table, the user can not change of tab until changes are posted or discarded. Tower Configuration Values The values of the tower configuration are the following: ame: Phase spacing: ame for the tower configuration. ame has to be unique. x and y coordinates of phases A, and C positions. Values are in feet for English system and meters for Metric (SI) system. When these values are modified, the phase spacing graph is automatically updated. raw axis has to be checked for x and y axis to be drawn in the graph. Page 5 of 13

Conductors per bundle: This section specifies the number of conductors (either single conductor or a bundle of conductors) per phase. The maximum number of conductors per bundle allowed is 4. Use regular spacing: Conductors spacing: Temperature: Frequency: System of units: When using a bundle of conductors, checking the Use Regular Spacing of check box will use the specified value as a regular spacing among the conductors. If the Use Regular Spacing of check box is not checked, then the custom conductors spacing section has to be used. x and y coordinates of the conductors in the bundle. Values are in feet for English system and meters for Metric (SI) system. When these values are modified, the bundle spacing graph is automatically updated. raw axis has to be checked for x and y axis to be drawn in the graph. Assumed temperature in Fahrenheit degrees for English system and Celsius degrees for Metric (SI) system. Frequency of the system in Hertz. The system of units used to specify the values of the tower configuration. The options are English system or Metric (SI) system. The units specified here not necessarily have to math the units specified in the Input ata section. Page 6 of 13

atabase The conductor type and tower configurations tables are read by default from the file conductors.mbd, which is a MS Access database. This database can be read from another *.mdb file by clicking on the Select Conductors and Configurations atabase button. ote: The conductors.mdb file can also be viewed and edited in MS Access. In order to edit a record in the database tables, the user can use the toolbar designed to do that. Following there is a figure showing this toolbar: The First, Prior, ext, and Last buttons are used to move among records. The Insert, elete and Edit buttons are used to insert, delete or edit the current record, respectively. While editing a record, the user can not change of tab until modifications are posted through the Post edit button or canceled with the Cancel edit button. The Refresh data button just refreshed the data of the entire table. Page 7 of 13

Calculations istributed Parameters Resistance R t R25 R50 R ( t ) 25 + 25 25 50 R50 R75 R ( t ) 50 + 50 50 75 R t 0 t 50 50 t R t t R 25 R 50 R 75 AC resistance at temperature t per phase per 1 mile in Ohms Assumed temperature in Celsius degrees AC resistance of the conductor at 60 Hz and 25 C per 1 mile in Ohms AC resistance of the conductor at 60 Hz and 50 C per 1 mile in Ohms AC resistance of the conductor at 60 Hz and 75 C per 1 mile in Ohms umber of conductors per phase Inductive Reactance X L 4π f 10 7 ln eq SL X L Inductive reactance in Ohms/meter f Frequency of the system in Hertz Geometric mean distance between phases in meters eq SL Geometric mean radius between conductors of one phase in meters The geometric mean distance between phases is defined as: eq 3 d, d, d istances between phases a-b, b-c, c-a, respectively in meters ab bc ca d ab d bc d ca Page 8 of 13

The geometric mean radius between conductors of one phase is defined as: SL GMR For 1 stranded conductor SL 4 1/ e r For 1 solid cylindrical conductor SL d km k 1 m 1 1 2 For more then 1 conductor bundle SL Geometric mean radius in meters r External radius of conductor in meters GMR Geometric mean radius given in tables for one stranded conductor d istance between conductors k and m in meters. km Susceptance ote: If k m, then conductor. d km SL for one stranded or solid cylindrical 2πε 2π f eq ln SC Susceptance in Siemens/meter f Frequency of the system in Hertz ε Constant permittivity 8.85418 10-12 Geometric mean distance between phases, defined as above eq SC Geometric mean radius between conductors of one phase using external radius in meters The geometric mean radius between conductors of one phase using external radius is defined as: SC r For 1 conductor SC d km k 1 m 1 1 2 For more then 1 conductor bundle Page 9 of 13

SC Geometric mean radius in meters r External radius of conductor in meters d istance between conductors k and m in meters. km ote: If k m, then d km r. Conductance Assumed G 0 G Conductance in Siemens/meter Lumped (Total) Parameters Resistance, Inductive Reactance, Conductance and Susceptance, using the equivalent π circuit (long line) Z R + jx Z c sinh γ l Y G + j 2 γ l tanh 2 Z c Z Total series impedance of line in Ohms Y Total series admittance of line in Siemens R Total series resistance of line in Ohms X Total series inductive reactance of line in Ohms G Total series conductance of line in Siemens Total series susceptance of line in Siemens Z c Characteristic impedance in Ohms γ Propagation constant in meters -1 l Line length in meters The characteristic impedance and propagation constant are defined as: Z c z y Page 10 of 13

γ zy z y istributed series impedance in Ohms/meter istributed series admittance in Siemens/meter The distributed series impedance and distributed series admittance are defined as: z R + jx y G + j R X G istributed series resistance in Ohms/meter istributed series inductive reactance in Ohms/meter istributed series conductance in Siemens/meter istributed series susceptance in Siemens/meter Surge Impedance Loading The surge impedance loading is defined as the power delivered by a lossless line to a load resistance equal to the surge (or characteristic) impedance Z c, and is given by: P SIL V Z C 2 P SIL V Total surge impedance loading in a three-phase line in VA Line-line nominal voltage in Volts Page 11 of 13

ase Values Impedance ase Z ( V ) ll 2 3φ S Z Impedance base in Ohms 3φ ll S Power base in VA V Line-line voltage base in Volts Admittance ase Y 1 Z Y Admittance base in Siemens Z Impedance base in Ohms Per Unit (PU) Parameters Resistance, Inductive Reactance, Conductance, Susceptance R X G PU PU PU PU R Z X Z G Y Y R PU Per unit resistance R Total series resistance in Ohms X PU Per unit Inductive reactance Page 12 of 13

X Total series inductive reactance in Ohms X PU Per unit conductance G Total series conductance in Siemens PU Per unit susceptance Total series susceptance in Siemens Z Impedance base in Ohms Admittance base in Siemens Y MVA To Ampere and Ampere To MVA Limits Conversion MVA to Ampere Limit Conversion Lim Amp Lim MVA 3V 10 6 Lim Amp Limit in Amperes Lim MVA Limit in MVAs V ominal voltage in Volts Ampere to MVA Limit Conversion Lim Lim MVA Amp 3V 6 10 Lim Amp Limit in Amperes Lim MVA Limit in MVAs V ominal voltage in Volts References [1] J.. Glover and M. S. Sarma, Power Systems analysis and design, rooks/cole, 3 rd edition, 2002. [2] A. R. ergen and V. Vittal, Power System Analysis, Prentice Hall, 2 nd edition, 2000. Page 13 of 13