Fire Resisting Rolling Shutters & Doors



Similar documents
Security Shutters, Retractable Security Gates, SeceuroBar & Aluminium Folding Shutter

FIRE RATED GLAZING System Guide

MODEL HSR-007 Direct Drive Rolling Steel

CATALOGO PRODOTTI PORTONI INDUSTRIALI COIBENTATI

SECTION COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here)

LPCB Red Book Listed Products and Passive Fire Protection Installer Schemes Answering the needs of the market

Schlüter -KERDI-BOARD Substrate, structural panel, bonded waterproofing

Loss Prevention Standard

STANDARD FOR NON-FIRE RATED ROLLING DOORS

V1504 Vertical Platform Lift OWNER S MANUAL

Fire. The Fire Installers Mate. A guide to fire alarm systems design

Architectural Specifications* MODEL HDE

V1504 Vertical Platform Lift OWNER S MANUAL

Relevant British, European and International standards

DESIGN CLARIFICATION (DC)

Fire 2This Technical Bulletin has been commissioned by the UK SIP Association in

Composite Panel Firewall Systems

PUBLIC VERTICAL PLATFORM LIFT PLANNING GUIDE

ModuSec. Secure and efficient IT room solutions. Turnkey Modular Construction Fast clean build to any size or shape

Fire Safety Requirements for Child Care Centre

SECTION SECTIONAL OVERHEAD DOORS 521 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS

(B613) VERTICAL PLATFORM LIFT PLANNING GUIDE

SHUTTER INSTALLATION INSTRUCTIONS. AUGUST 2006 Version 2

Approved Document Q: Security

High-speed folding doors. F Series

- 5 - Table1. Maximum Compartment Volumes

Manual piston sampler...m 11

Architectural Specifications MODEL HDXL Fairview Road, Unit #2, Barrie, Ontario L4N 8Z8

AVAILABLE TO DOWNLOAD ON THE APOLLO APP. Fire Alarm Systems Design. a guide to BS5839

BUILDING CONTROL GUIDANCE SHEET REPLACEMENT WINDOWS AND DOORS Last updated 16/11/2010

Belt Conveyor System

ABLOY DOOR AUTOMATICS Easy access for all types of swing doors

Product Data Sheets. Belt Conveyor System

PART 1 GENERAL 1.1 SECTION INCLUDES

Building Control Guidance Note

LOADING DOCK EQUIPMENT. A. Section Concrete Forms and Accessories: Placement of anchors into concrete.

Office of the State Fire Marshal. Fire Rated Doors

Display hidden notes to specifier. (Don't know how? Click Here) A. Advanced Upcoiling Security Grilles, power operated.

Excerpts from the Canadian National Building Code (NBC)

Ontario Fire Code SECTION 5.13 DIP TANKS. Illustrated Commentary. Office of the Ontario Fire Marshal

DIAMOND Retractable Rodding Robot Model SPRAYROD-R

Code of Practice for fire resisting metal doorsets

Drayton Digistat +2RF/+3RF

39HQ Airovision Air Handling Units

Fire precautions in dwellings. Private sector housing Providing homes building communities

TPM 006/99 Revision 1 VALID FROM: 8/2/2013 REPLACEMENT FOR TPM 006/99 FIRE SHUTTER

plumbing products guide

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & Instructions For Installation, Operation & Maintenance

Technical data sheet PVC Bi-fold doors

Automatic Door Selection Guide

PHA 2000 PHB 3000 EXIT PAD

Glass partitions SFB 3074

FIRERAY 2000 Installation Guide

Services Enclosures and Protected Shafts - Maintaining Compartmentation

SELF OR MANUALLY CLOSING FLOOD BARRIER PRODUCT INFORMATION

Tel: Sales: STORAGE CABINETS. PREMIERSHIELD anti-bacterial powder coating system. quality products made in the UK

FIRE DAMPER APPLICATION GUIDE

CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C Date of issue , Updated July 1, 2011

Flash Butt Welding Machines

SECTION FireGard ROLLING FIRE DOORS / SMOKESHIELD FIRE DOORS

Cannon T4 Modular Data Centres. For Outside Deployment & Challenging Environments

Installation Instructions

RADAR

SECTION G2: CABLE PROCESSOR MODULE MAINTENANCE

Installation Instructions

Profiles in stock Standard catalogue. Discover the possibilities with aluminium profiles from Sapa

garage door operators

Guidance on loft conversions in two-storey houses

Fire Resistant Systems

Awning Instructions. Full Cassette 1.5m to 6m

Quality Operators for Garage Doors and Entrance Gates. Garage door operator LIFTRONIC for up-and-over doors and sectional doors

Morgue refrigeration unit

BOQ SPECIFICATIONS. The Blind system consist of a coated aluminium tube of 38 mm diameter with provision of fabric clamping.

Insulated Roof & Wall Panels. Product Data Sheet. Trapezoidal Insulated Roof Panels KS1000 RW

TARIFF CODE and updates standard

Windows, French doors, folding windows, terrace doors SFB 1074 with low U-values

Built to Last. Built for Beauty. Good. Solid. Logix. TM

TELESCOPE Motorized Lighting Suspension

Vario Roof. Model R HO 04 Vario Roof (CrullG)

SECTION MediaStation Model 125 Electric Lateral Files (ELF)

NRG 75 CRF NRG GREENBOARD WALL SYSTEM

TFL CUSTOM FIREPLACES WITH MASONRY BRICK LININGS. standard INSTALLATION SPECIFICATION INTO TIMBER FRAMING

CERTIFICATE OF APPROVAL No CF 291 SCHOTT UK LIMITED

IH E Sigma Island 90

Variety of Control Options Control is possible via wall switches, remote control systems or integration into building management systems.

1-Way Chilled Water Cassettes KCO 60, 90 & 120. Technical Brochure. TM KCO-W.1GB Date : November 2005 Supersedes : None

/CHI BUYLINE Rolling Steel. Buyer s Guide THE DOOR TO QUALITY.

How To Use A Power Supply On A Powerline 2.2 (Ai)

The replacement or modification of existing windows shall comply with the following requirements:

Dubai Municipality Standard DMS 1: Part 5: 2004

contents Leading the way in intelligent automation INELS Wireless? Why Click Accessories Complete control

Safety Storage Cabinets

Sliding and Folding Door Fittings Sliding Door Accessories

FIRE DETECTION AND ALARM SYSTEMS

Decree of the Ministry of the Environment on fire safety of ventilation systems

ModuSec. Secure and efficient IT room solutions Composite Panel Systems Compared. Panel Systems are not all the same!

!!!!!! !!! Decra Plus DPSW010 DPSTW011 DPSW012 DPSW013 DPSW014 DPSW015 DPSW016 DPSW020 DPSW021 DPSW024 DPSW030 DPSW031 DPSW035 DPSW030 DPSW031 DPSW035

QUICK BUILD DEMOUNTABLE CONTAINERS & WAREHOUSES. Construct the Quick-Build Container in under 5 minutes!

Transcription:

Fire Resisting Rolling Shutters & Doors

Fire Resisting Rolling Shutters What is a fire resisting rolling shutter? A traditional single skin fire resisting rolling shutter looks and operates in a similar way to a standard steel rolling shutter. The physical differences are that the materials used are heavier and there are more fixings required. Syston Doors can also provide alternative physical fire shutter products as shown in this brochure. Fire Shutter Structural Recommendations The structure supporting the rolling shutter must be a fire resistant separating element (to BS476, Part 20, 21, 22, 1987), having a fire resistance equal or greater than that required of the rolling shutter itself and must be capable of supporting the rolling shutter for the required fire resistance period without compromising the fire performance of the rolling shutter. Consideration must be given to the loads imposed by the various rolling shutter components, i.e. end plates and the barrel support brackets. Fixing to Masonry Openings. Opening to be constructed from masonry, reinforced concrete or dense concrete blocks (7 Nm and above) and have a fire resistance equal or greater to that of the door. Lightweight and hollow blocks are NOT suitable. All concrete/masonry elements must be designed in accordance with BS5628: Part 3:1985 and have a density of > 600kg/m 3. Lintels spanning the structural opening should comply with BS8810: Part 1:1997. Client to ensure that openings are plumb and square and that the structure will accept rawlbolt type fixings without cracking. Subject to the fire shutter being fitted to a flat surface, gaps of up to 6mm are acceptable (for a distance of 150mm), but if, due to an uneven structural finish, larger gaps are apparent, they must be sealed with a suitable fire retardant material, e.g. plaster, fire retardant mastic seal (non-intumescent). Syston Doors do not include this sealing. Fixing to Steel Openings Where fire resisting rolling shutters are fitted to steel, the steel must be insulated and thermal bridging effects considered where insulation has been breached. It is recommended that a critical steel temperature of 400 0 C and steel sections with an Hp/A below 230m-1 are used for designing fire resisting steel supporting structures. Fixing to Timber Partitions Fire resisting rolling shutters can be fixed to non-loadbearing timber framed or steel framed partitions (with suitable timber inserts all round) up to 2750mm wide x 3250mm high, (maximum area 10m 2 ), for up to 60 minutes under cover of BRE test certificate FG 7941 N. The opening must be capable of carrying the weight of the shutter and be equal or greater than the fire resistance of the rolling shutter assembly. It is most important that the Contractor adheres to the opening construction details, as these are also covered by the assessment and as such become the CONTRACTOR S RESPONSIBILITY. Fire testing We do not as standard include for a return journey involving a fire test after the original installation. We can include this at extra cost. Maintenance Please note that it is a requirement under Regulatory Reform (Fire Safety) Order 2005, that fire resisting Rolling Shutters are tested every six months. Full width access should therefore be maintained to the shutter to enable this to be carried out. Syston Doors can offer routine testing and maintenance contracts on application. If no contract is entered into we cannot take any responsibility for the working condition of the shutters after the guarantee period. Fire Shutters over fire exits and escape routes Appendix B of the Buildings Regulations Approved Document B states that roller shutters across a means of escape should only be released by a heat sensor, such as a fusible link or electric heat detector, in the immediate vicinity of the door. Closure of shutters in such locations should not be initiated by smoke detectors or a fire alarm system, unless the shutter is also intended to partially descend to form part of a boundary to a smoke reservoir. Note Removable guides, bottom rubber seals, brush seals, safety edges and wicket gates cannot be fitted to fire shutters. 2

Shutter shown with optional key lock 76mm laths 50mm laths Flame Shield 120 Tubular Motor Operated Fire Shutter Application Flameshield 120 240v single phase tubular motor operated fire shutters provide an attractive and space friendly fire shutter solution with a fire resistance as standard of up to 120 minutes (2 hours) and for openings up to 4800mm wide x 1900mm high (see size grid). The shutter is constructed to Warrington Fire Research Centre WARRES No. 145904, the test is in accordance with clause 8 of BS476 Part 22. The attractive 50mm flat faced lath for openings up to 3500mm wide x 2500mm high, make it most suitable for servery type openings or where aesthetic appearance is important. Over this size a traditional 76mm curved lath is used, but still offers the benefits of a space friendly coil casing and guide detail. General Specification Curtain Shutter curtains are constructed from 50mm flat faced laths up to 3500mm wide x 2500mm high or 76mm traditional curved laths over this size, with a standard Tee bottom rail. (If smaller openings are adjacent to larger openings the laths on the smaller openings would normally be 76mm to ensure all match). Hood (Coil Casing) A profiled galvanised sheet steel hood is included as standard. A fascia can be included at extra cost on fit within applications. Dependent on the fire rating of the shutter and the size of the opening, the shutter could require a hood support bracket. 3

Guides Vertical guides are fabricated from 50mm deep galvanised steel channels. Wider openings will use 65mm deep channels. Finish Standard finish is, curtain, bottom rail, guides & hood galvanised, end plates and fixing angles are finished in one coat of primer paint. Powder coated finish to a standard range of BS/RAL colours available at extra cost. Locking A lock is not normally included. A centre bottom rail key lock which sends a bolt into each side guide can be included at extra cost. Operation Powered by a single phase 240v tubular motor with normal day to day operation of the shutter by rocker switch. Manual override by hand crank can be included at extra cost. Available Modes of Activation Fusible Link release On activation of the fusible link from a local heat source of 68 C, this will send a signal to the relay which will signal the shutter to power down from the maintained supply or alternatively from the optional battery back up unit. Fire Alarm link By use of a fire alarm relay the shutter will close under power. The unit will require a maintained supply or alternatively we can supply with a Battery Back Up unit. Volt free fire alarm signal required. Syston Doors do not include for connecting into the fire alarm system. Audio Visual Warning Closure For use when an audio & visual warning is required of the shutter closing. The unit also includes a facility for a delayed closing of the shutter. The fire alarm signal is connected directly into this unit. On activation from the fire alarm the unit starts to flash & sound with the shutter closing after a pre-determined delay (10-240 seconds). Fixing to Partitions Flameshield 120 can be fixed to non-loadbearing timber framed or steel framed partitions (with suitable timber inserts all round) up to 2750mm wide x 3250mm high (maximum area 10m 2 ) up to 60 minutes under cover of the above certification. For larger openings see our Flame Shield 240 range of fire shutters. Clear Height 700 900 1100 1300 1500 1700 1900 2100 2300 2500 2700 2900 3100 3300 3500 3700 3900 4100 Sizes available for Flame Shield 120 Clear Width 800 1000 1200 1400 1600 1800 2000 2200 2400 2600 2800 3000 3200 3400 3600 3800 4000 4200 4400 4600 4800 50mm flat laths within yellow area or 75mm traditional (curved) laths 75mm Traditional(curved) laths 4

Technical Information Flame Shield 120 Door Weight Typically 30 kg/m 2. Face Fitted Fit Within Minimum width available is 800mm overall end plates. Full width access to be maintained for future service and maintenance. 5

Flame Shield 240 Electrically Operated Fire Shutter Application Designed for use where the tube motor operated fire shutter is not suitable and providing 30, 60, 120 or 240 minutes of protection from fire this shutter has been tested to BS476 Part 22. Flame Shield 240 provides fire protection for all uses including department stores, shopping centres, warehouses, factories, schools and all other areas where protection from the spread of fire is required. Fixing to Partitions Flame Shield 240 can be fixed to non-load bearing timber or steel framed partitions (with suitable timber inserts all round) up to 2750mm wide x 3250mm high (Maximum area 10m 2 ) up to 60 minutes. General Specification Curtain Shutter curtains are constructed from 76mm curved section steel laths, which are securely held in place by end locks. Lath thickness vary dependant on opening size and fire rating. Bottom rails are roll formed galvanised Tee sections. Hood (Coil Casing) All fire shutters as standard include a galvanised sheet steel hood (coil casing). A motor cover will be included on all shutters under 2500mm high and optionally over this height. Guides 65mm x 3mm (minimum) mild steel channels mounted on rolled steel angles. Endplates Mild steel of appropriate thickness relative to door size. 6

Type of Operation Hand Chain Available up to 4000mm wide x 4000mm and suitable for applications where the shutter is held open, closing only in the event of a fire. Manual closing is achieved by releasing a pull cord, which allows a controlled descent via a gear unit at approximately 100mm/second. Operating by the hand chain is a slow process and power operation is recommended when everyday use is required. Electric Suitable for all sizes of shutter, the motor is either single phase (240 Volt 50 Hz) or 3 phase (415 Volt 50 Hz) dependant on size of door. A controlled descent of 100mm per second (approx.) is an inbuilt safety feature. In the event of power failure, manual override is achieved by pulling a pull cord to close the shutter under controlled descent and a hand chain to open. The handchain override is designed for emergency use only. As standard each shutter will include an open/stop/close push button station mounted on the motor side at approximately 1500mm above the finished floor allowing sight of the shutter during normal operation. Other control options available are shown under Options. All switchgear unless otherwise stated are surface mounted. Modes of Activation Option 1 Self closing by means of a thermal fusible link activated at a temperature of 68 C and mounted to the underside of the hood Option2 *24v DC auto resetting solenoid release device connected to the fire alarm/smoke detector. Solenoid automatically resets when the shutter is fully opened by pressing the up button and when the alarm has been turned off. (On hand chain operated shutters the solenoid is reset manually by pulling on a cable). Syston Doors do NOT include for connecting into the fire alarm. Option 3 All as Option 2 but with mechanical fusible link back up. Size Parameters Chain operated 4000 x 4000mm Power operated 7000 x 7000mm Larger sizes available on application. Finish All components other than curtain, bottom rail & hood finished primed. Curtain, bottom rail & hood (& motor cover if fitted) are galvanised. Powder coated finish to BS/RAL colours available at extra cost. Options Shutter Closing audio-visual warning panel with in-built time delay to one or both sides of shutter. Battery back up for solenoid release device. Fuse link back up for shutter fitted with solenoid release device. Key switch control. Galvanised sheet steel fascia. Motor cover (usually included if under 2500mm high). Part close facility using audio visual warning panel. (Shutter to act as smoke curtain with full closure after pre-set delay. Shutter MUST have a maintained power supply to accommodate this function). The fire alarm circuit must provide the supply for the solenoid (0.5 amps) with an initial supply of 3.5 amps for 20 30 m/seconds to release the shutter but only when in the alarm condition. (If the fire alarm circuit is unable to provide a 24v DC supply for the solenoid or ancillaries a battery back-up system can be provided at extra cost). Note! To comply with current legislation fire shutters cannot be linked to fire alarm systems if they are over fire exits or cover a fire exit route. They can only be fitted with a device, which will close the shutter, by a local heat source i.e. fusible link. 7 Flame Shield audio visual warning panel

Technical Information Flame Shield 240 Face Fitted Fit Within Minimum fixing face if fitted to steel is 75mm Sideroom requirements A B 3000 x 3000 153 170 5000 x 5000 153 170 7000 x 7000 153 170 Headroom requirements X Y 3000 x 3000 350 550 5000 x 5000 400 600 7000 x 7000 450 650 Full width access to be maintained for future service and maintenance. Minimum width available is 800mm overall end plates. Arrangement Maximum size (mm) W x H 1 Hour 2 Hour 4 Hour Hand Chain/Electric 4000 x 2500 Electric 3000 x 5000 Roller Support Bracket Electric 4000 x 2500 1 1 Electric 5000 x 5000 1 1 Electric 6000 x 5000 1 2 Electric 6000 x 6000 1 1 2 Electric 7000 x 7000 1 2 3 Door Weight Varies with opening size dependant on lath/barrel/casing requirements but typically 45 kg/m 2 approximately. 8

Technical Information Further technical information is given on our website... Self-Coiling Fire Shutter Application Designed for smaller openings the Syston Doors self-coiling fire rolling shutter has been tested by the Loss Prevention Council (Report No.TE6697) and assesed by the BRE, Certificate CC10571, and can be face fixed or fitted within the opening. Operating via a counterbalanced sprung roller, the shutter will close automatically by fusible link at 68 C closing by means of a weight bar under gravity. We can also offer an automatic release system (solenoid) to allow the shutter to close on an alarm signal. The fire alarm must provide the supply for the solenoid (90m/amps). Syston Doors do not include for connecting into the fire alarm. *Maximum size: 1800mm clear width x 2100mm clear height. General Specification Curtain Shutter curtains are constructed from 50mm flat faced laths with a standard Tee bottom rail. Hood (Coil Casing) A galvanised sheet steel hood is included as standard. A fascia can be included if required at extra cost. Guides Vertical guides are fabricated from 50mm deep galvanised steel channels. Locking Standard locking is by bottom rail mounted shootbolts. Cylinder key operated locks are available at extra cost. Finish Standard finish is, curtain, bottom rail, guides & hood/fascia galvanised. Powder coated finish to a standard range of BS/RAL colours available at extra cost *N.B. The maximum clear opening height available with a push up fire rolling shutter is 2100mm. Above this size an electrically operated shutter must be used. Manual shutters can be used for normal security but will be heavier to lift than non fire rated shutters. This should be considered if doors are used regularly. For controlled descent and ease of use we recommend electrically operated fire shutters. 9 HEIGHT Y Z F 0-1200 230 290 50 1201-2000 254 314 65 2001-2100 280 340 65 ALL DIMENSIONS IN MILLIMETRES WEIGHT 30kg/m 2

Fireflex R Radiant Heat Reducing Fire Resisting Rolling Shutter Application Tested by the Loss Prevention Council (Test Report 220737) to an integrity of 240 minutes (4 hours) for openings up to 50 m 2 Fireflex is an obvious choice where increased risk of fire is a major concern. Fireflex provides a substantial safety barrier between the source of the fire and any precious or dangerously flammable stock. Fireflex is the perfect application for hospitals, shopping centres and industry. Designed for internal or external applications where increased fire protection is required. It provides radiant heat protection with reliable operation through a simple control panel that can be adapted for a range of activation methods. Fireflex is power operated with controlled descent following automatic activation. A safety brake is included as standard at the non motor end. Due to its unique construction, the radiant heat levels around Fireflex drop from 65kw m 2 to 2.7 kw m 2. This means that combustible materials can be stored 500mm away from a 1200 o C inferno, increasing floor space and reducing risk and break down of fire compartmentation. Fireflex R also has a weighted sound reduction of 18 db (BS5821 Part 3: 1984). General Specification Curtain Manufactured from pre galvanised material designed to provide a hollow section panel with ceramic infill. Each section is 100mm high with twin ribbed face for rigidity. The curtain is held in position with purposely designed end fittings which act as a curtain alignment system. The bottom panel is terminated with a galvanised steel plate with horizontal and vertical slots. Hood (Coil Casing) All Fireflex R shutters include a galvanised sheet hood as standard with optional motor cover. (Motor cover always included if less than 2500mm high). Guides Formed from pre galvanised steel. Endplates Mild steel of appropriate thickness relative to door size. Finish Standard finish to all parts is galvanised. Powder coated finish to a standard range of BS/RAL colours available at extra cost 10

Operation Fireflex Shutters are power operated by a 3 phase & neutral motor with various options of release: Level 1 Fusible Link Operation Normal operation by push button station or keyswitch with fuse link to close shutter at local heat source of 75 o C. *Level 2 Alarm activation with manual reset Normal operation by push button station or keyswitch with solenoid release to close shutter following fire alarm signal with manual reset of solenoid by pull cables. *Level 3 Alarm activation with automatic reset Normal operation by push button station or keyswitch with solenoid release to close shutter following fire alarm signal with automatic reset of solenoid once alarm is switched off by fully opening shutter. *Level 4 Alarm activation with automatic reset and part close facility Normal operation by push button station or keyswitch with solenoid release to close shutter following fire alarm signal with automatic reset of solenoid once alarm is switched off by fully opening shutter. Shutter can also part close to act as a smoke curtain, fully closing after an adjustable delay. Shutter must have maintained supply for this function. *For Level 2, 3 and 4 Audible Visual (with adjustable delay timer) can be included to one or both sides of the opening. Fire Alarm requirements The Fire Alarm circuit must provide the supply for the 24v DC solenoid (0.5 amps) with an initial supply of 3.5 amps for 20-30 m/seconds to release the shutter but only when in the alarm condition. If the fire alarm is unable to provide a 24v DC supply a battery back up system is available at extra cost. The 24v DC supply needs to be provided separately from that of the fire alarm system as under the requirements of BS5839 Clause 19, the connection of such equipment is specifically prohibited. Syston Doors DO NOT include for connecting into the fire alarm circuit. Note! To comply with current legislation fire shutters cannot be linked to fire alarm systems if they are over fire exits or are on a fire exit route. They can only be fitted with a device, which will close the shutter, by a local heat source i.e. fusible link. Fireflex audio visual warning device 11

Technical Information Fireflex R Elevation Plan Width Height A B C 2500 2500 430 525 With hood 635 3000 3000 500 705 support 715 4000 4000 500 705 over 3000mm 715 5000 5000 550 755 wide 865 6000 6000 600 805 915 7000 7000 650 855 915 Distance from the opening 6 5 4 3 2 1 Single Shutter Double Shutter 500mm Fireflex 0 1 2 3 4 5 6 7 Distance between structure in metres Radaint heat profile showning the safe distance storage of combustable materials for a 7m x7m opening. Irradiance - kw sq m 70 SINGLE SKINNED ROLLER SHUTTER 65 kw sq m 60 50 40 30 20 10 FIREFLEX 3.5 kw sq m 0 0 30 60 90 120 150 180 210 240 Time - Minutes Irradiance recorded 3 metres from centre of unexposed face 12

Syston Doors is a leading manufacturer and supplier of industrial doors, rolling shutters and associated products and has developed a comprehensive range to meet the requirements of the specifier, designer and end user. Established since 1920 and with a wealth of experience, Syston Doors is based in Syston, near Leicester at the heart of the motorway network, offering nationwide service. Our range includes: Rolling Shutters & Grilles in Steel, Aluminium and Timber Fire Resisting Rolling Shutters Rapid Action Doors Steel Doorsets Folding Shutter Doors Dock Shelters, Seals & Dock Levellers Insulated Rolling Shutters Insulated Sectional Doors Transparent Rolling Door Systems Sliding Folding Closures PVC Strip Curtains & Rubber Crash Doors Collapsible Grilles for Windows & Doorways Window Rolling Shutters Moveable Walls & Concertina Screens Domestic Garage Doors & Rolling Shutters Retractable Awnings & Shading Systems Nationwide Repair & Service to all makes & types of Industrial Door Albert Street, Syston, Leicester LE7 2JB, U.K. Telephone: (0116) 260 8841 Fax: (0116) 264 0846 email: sales@syston.com or visit www.syston.com We reserve the right to change or modify specification without alteration to this leaflet. Pictures shown for illustration purposes only. October 2006 E.&O.E. Please note, this brochure does not form part of any contract.