2008 powertrack and floorboxes



Similar documents
Masterseal Plus TM. ingress protected wiring devices. technical hotline +44 (0) IP66. Improved catch.

Complete units. Complete underfloor box for one Modul 45 socket and two data connection sockets. Complete service outlets

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & Instructions For Installation, Operation & Maintenance

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV

GE Power Controls. MiniFORM Switchboards

1. Description. 2. List of Accessories included A B C F G H

KAM A Lighting Busbar System KAP A Plug-in Busbar Distribution System

Masterseal TM. Compact. Ingress Protected IP66

P System Cubicles. Certified for more safety

electrics P OW E R E N T RY B A S I C S P OW E R & C O M M U N I C AT I O N S B A S I C S P OW E R D I S T R I B U T I O N B A S I C S

This unit is a pump that will clear the waste from a domestic shower and washbasin, bath, washing machine, glass washer and a sink.

Distribution Boards & Consumer Units

Voltage Rated operating voltage [kv] Rated power frequency withstand voltage [kv] Rated lightning impulse withstand voltage [kv]

ADS8 IP54 Direct-On-Line Starter Technical Focus. Replaces ADS7 Rated up to 9kW

Contractors Guide Central Inverter System Installation

19" GERMANY EXPORT RACK QUALITY PRODUCT FOR THE BEST WORK NEW DESIGN CABLE MANAGEMENT PANEL WALL RACK CABINET 15 U VENTILATING FAN

LIEBERT VNSA Installation Sheet

Slimline Plus. Catalogue No. R6

New Media Power Socket Outlets. New Media Power Socket Outlets

GENUINE PARTS INSTALLATION INSTRUCTIONS

Depending on which elastic support you have you can secure the V2 power unit to the following seat bracket tubes: EXTERNAL DIAMETER 27.

Decorative Metal Wiring Accessories in Assorted Plate Finishes

OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE

Back-Up Camera Installation Guide

Switchboard system. NorLine 800

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

INFRARED QUARTZ WALL HEATER

REB 1 REB 3 REB 5 REB 6 REB 8 REB 10 REB 12 REB 16

COMPACT DATA FAST AND SIMPLE DATA CABLE TRUNKING. Building Solutions Automotive Industry

Transformers from 25va to 500kva. Standard despatch in days not weeks

Trade of Electrician. Three-phase Distribution Boards And Socket Circuits

Stainless Steel and Mild Steel Enclosures. Stainless Steel and Mild Steel Enclosures

INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks

ATTENTION This is a general warning that failure to follow instructions could result in poor functioning of the unit.

Replacing the vacuum tube

Installation and User Instructions Unvented Electric Storage Water Heater Models: S10UNV, S15UNV.

Installation and User Instructions Aquarius Undersink Vented Water Heaters Models: AU7/3, AU7/1, AU10/3, AU10/1.

GUIDE TO THE AM2 EXAM

Submit shop drawings for equipment provided under this section Shop drawings shall indicate:

All work must conform to the National Electric Code, latest edition, and all other applicable codes and regulations.

Time needed: ~3h for lid replacement only. Add 1h for operation harness in lid and ~2h more for installing drive unit and cable harness in trunk.

Digital input modules

Document number RS-PRD Revision 05 Date 20/10/2009 Page 1/30

2a. IEM Indoor Metal Clad Medium Voltage Switchgear 15KV a. Section INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std.

Laserlyte-Flex Alignment System

IEC Connectors. Introduction

NEW RANGE OF CABINETS DRIVIATM. Innovation at your service. THE GLOBAL SPECIALIST in electrical and digital building infrastructures

2003/2004/2005 TOYOTA COROLLA

Installation Manual For Support Call or

ELECTRONICS G H I J K L M

Category 6 Solutions. 4. Category 6 Solutions. 09/ IN TrueNet Structured Cabling. Introduction Cable Patch Panels... 4.

Medical Lighting. XL4 Patient Light

OUTDOOR DISCONNECTORS A division of ACTOM (Pty) Ltd

Awning Instructions. Full Cassette 1.5m to 6m

Linear Luminaire with LED Series EXLUX 6402/2

Please also see 10 golden rules for correct Saniflo installation on

Linkeo 19" freestanding cabinets

SOLAR PV STANDARD ELECTRICAL PLAN Microinverter Systems for Single Family Dwellings

Linear Luminaire for Fluorescent Lamps Series EXLUX 6001

Tyan Computer. Transport PX22. Service Engineer s Manual

4.3-inch Back-Up Camera

WIND ALARM. Wind Speed Alarm. Wind Speed. Set Point 2. Set Point 1 NEW BEDFORD, MA USA

EVC40 EMERGENCY VOICE COMMUNICATION SYSTEM

ABB. Installation Enclosures Meter Boxes. SMB s. DMB s. Enclosures

42U/45U 28" Wide Rack Installation & Service Guide

DOMESTIC ELECTRICAL INSTALLATION CERTIFICATE (Requirements for Electrical Installations BS 7671 IEE Wiring Regulations)

Rittal s Comprehensive Family Of... NETWORK RACK SOLUTIONS

LSA-PLUS Series 2 Connection and Disconnection Modules and Accessories

Electronics Ltd. Presenting. Power, Intelligence... with a sense of feeling

Electrical for Detached Garages: Updated Feb 19, 2016 for 2015 CE Code in force Jan. 1, Underground branch circuit feeding a detached garage:

How To Power A Power Supply On A Powerline From A Power Source To A Power Box

Low Voltage Switchboards The Best Technical Solution for Your Ship

Installation Guide for Hive Active Heating

KEYLESS ENTRY UPGRADE SECURITY SYSTEM for 2004 TOYOTA HIGHLANDER

Dlp-s & WIRING DEVICES. THE MAXIMUM FReeDOM OF ChOICe. SNAP-ON AND UNIVERSAL TRUNKING FOR high AND LOW CURReNt DIStRIBUtION

Processor. Installation Guide

Metallic and Non-Metallic Air Conditioning Disconnects. A Complete Family of. Disconnects with Exclusive Time Saving Features

Bathroom Cabinet. Installation & User Guide. Illuminated Mirrors.

19" Data Racks. Adjustable feet To compensate for uneven floors and assure great stability all feet can be up to 20 mm adjusted.

THERMONET UNDERFLOOR HEATING STANDARD THERMOSTAT KIT STOCK CODE 5260

LV MCC LOW VOLTAGE SWITCHGEAR MOTOR CONTROL CENTRE PRODUCT GUIDE

TriLine ASSEMBLY System PowerModules

SERVER ROOM CABINET INSTALLATION CONCEPTS

CORNER FRIDGE REFRIGERATION UNIT INSTALLATION AND OPERATION INSTRUCTIONS

Drayton Digistat +2RF/+3RF

3 IN 1 BATHROOM HEATER

FIRST STOP SAFETY 1 PAT-IT. Portable Appliance Tester. User Manual. Issue 1.6

Medium Voltage Products. ZN1 12 kv arc-proof air-insulated switchgear for primary distribution

Cabinets 101: Configuring A Network Or Server Cabinet

PANEL CUT-OUT DIMENSIONS

ELEKTROTEHNI KO PODJETJE Leskoπkova cesta 12, 1000 Ljubljana, SLOVENIA

Single Channel Loop Detector

IT&T Infrastructure Standards

AMFA-27 AMFA-29. Operator s Manual & Installation Instructions. Rev. 2.5

HMI display Installation Guide

SSG PRODUCTS FOR SHIPS AND OFFSHORE

Busbar Trunking Systems for Safe and Flexible Power Distribution up to 6300A. 8PS Busbar Short Form Catalogue sivacon 8PS BUSBAR SYSTEMS

VOYAGER 570G. 744A Sprayer Control

LANC Fibre Patch Panel Solution

INSTALLATION INSTRUCTIONS

Transcription:

ELECTRIUM SALES LIMITED Commercial Centre, Lakeside Plaza,Walkmill Lane, Bridgtown, Cannock WS11 0XE. email: info@electrium.co.uk Web: www.electrium.co.uk UK SALES Telephone: 01543 455218 Facsimile: 01543 455119 email: britmac.sales@electrium.co.uk EXPORT SALES Telephone: +44 1543 455049 Facsimile: +44 1543 455048 email: export@electrium.co.uk DUBAI OFFICE Telephone: +971 4 2666403 Facsimile:+971 4 2666031 DUBLIN OFFICE Telephone: +353 1 4513303 Facsimile:+353 1 4513242 Although every effort has been made to ensure accuracy in the compilation of the technical detail within this publication, specifications and performance data are constantly changing. Latest details can be obtained from Crabtree. Publication No. CMXXXX 03/08 Printed in England. 2008 powertrack and floorboxes

POWER TRACK UNDERFLOOR SYSTEM The Power track module is a 63A single phase busbar unit with the facility to accept a tap-off unit every 300mm, this allows the removal or addition of tap off units without the need to isolate the complete system. The system has been designed with the electrical contractor in mind, where speed and ease of installation are paramount, with push fit connectors on both the track connections and feed units. There is a keying system on the track end which operates the shutter mechanism and allows correct location. The Britmac underfloor power track system has undergone some radical changes to meet the ever increasing power requirements of the workplace. The system consists of a series of fully enclosed single phase busbar module units and is designed to be assembled directly onto the floor slab of a cavity floor installation using the integral floor fixing brackets. The track modules have a simple and quick push fit connection allowing for rapid on site assembly. The modules are available as standard 2P+E, Clean Earth 2P+E+CE and dual system 4P+E+CE. The system has been designed with minimal parts to assist the contractor fitting out on site. Direct to floor assembly Universal cable feeder unit Standard Earth 2P+E - Blue Clean Earth 2P+E+CE - Yellow Dual system 4P+E+CE - Brown The modules come in standard lengths, all compatible with standard floor modules and cavity floor trunking sizes. Each length comes complete with an innovative method of track fixing. The fixing bracket simply swivels out to enable solid fixing to the floor screed. The standard tap off units comprises a 32A unfused plug fitted with flexible metal conduit. Where lengths longer than 3m are required, a fused tap off unit is fitted and wired with the appropriate length of cable. All tap offs have a keying system which ensures that the correct tap off is fitted, and that it is fitted correctly. Transparent dust covers are provided to enable easy recognition of the system installed. The dust cover slides along the track length to enable tap off plug insertion. Push fit 49mm clearance height Colour coded Non interchangeable pin configuration Pre-wired tap off unit Complies with BS 7671: 2008 regulation 543.7

UPFLH UNDERFLOOR POWER TRACK MODULES l Track Length Standard Clean Earth Dual Track 1200mm UPT12 UPT12TE UPT12DE 2400mm UPT24 UPT24TE UPT24DE 3600mm UPT36 UPT36TE UPT36DE Tap off socket at 300mm intervals complete with clear dust cover Track fixing brackets factory fitted 2 on 1.2m, 2 on 2.4m and 3 on 3.6m Each length comes with a shuttered interconnection and a track stop end Colour Coded: Blue - Standard Yellow - Clean Earth Brown - Dual Earth CABLE SUPPLY FEED IN l Feed unit for standard & clean Earth system Feed unit for Dual Track system CABLE SUPPLY FEED ON l Universal feed unit UPFLH UPFLH/DE UPFRH The Cable Supply feed end allows the termination of the incoming flexible cables. The generously sized terminals accept up to 16mm 2 cables 1 x 25mm diameter conduit entry hole TECHNICAL DATA UNDERFLOOR POWER TRACK MODULES Conditional Short Circuit Rating TRACK Short circuit protection provided by fuselinks BS-88 and BS 1361 100 amp maximum. Prospective current 16.5kA Mechanical withstand 10kA peak Thermal withstand 1200A for 0.1 seconds TAP-OFF UNITS Mechanical withstand 10kA peak Thermal withstand 1200A for 0.1 seconds Earth Fault Loop Impedance The IEE Wiring Regulations require accurate determination of the total earth loop impedance, which must be low enough to ensure that the protective device will operate within the specified time, which for circuits incorporating socket outlets is 0.4 seconds. The values for the Britmac System for calculating the earth fault loop impedance are as follows: Phase busbar 1.5mV/m Earth busbar & housing 0.65mV/m Earth busbar (Clean Earth) 1.5mV/m Track connector 0.4mV Supply connector 0.2mV 32A tap-off (4mm 2 x 3m), line & earth30mv Volt Drop, Combined Phase & Neutral Busbar (line & neutral) 3.3mV/A/m Track connector 0.44mV/A Supply connector 0.22mV/A 32A tap-off (4mm 2 x 3m), line & earth11.0mv/a/m Cable Capacity of Terminals Supply connector 16mm 2 Construction TRACK Body extrusion Galvanised Steel Track base Galvanised steel Busbar High conductivity copper Degree of protection Track IP4X; In-feed housing IP3X TAP-OFF UNITS Ordinary Clean Earth and Dual Track tap-offs are non-interchangeable. All types available in fused and unfused versions. 32A tap-off unit The 32A tap-off is unfused with 3 metres of 16mm diameter flexible conduit and 4mm 2 cables to BS 6004:1995 which are terminated in the tap-off via welded connections. Fused tap-off unit Required where conduit lengths greater than 3 metres are used. The tap-off unit is used as standard at 13 amps and is fitted to the specified length of 16mm diameter conduit and 2.5mm 2 cables to BS 6004:1995 which are terminated in the tap-off via welded connections. The flexible conduit is manufactured to BSEN 50086-1 STANDARDS BSEN 60439: Part 1 & Part 2. The track system enables compliance with the latest IEE Wiring Regulations, BS 7671. TRACK CURRENT RATING 63 amp, 240V ac; 50Hz single phase ambient temperature 25C. FLEXIBLE CORNER UNIT l Standard Clean Earth Dual Track FRONT ELEVATION SIDE ELEVATION 1 Metre Length UPFC UPFCTE UPFCDE Comes complete with feed in and feed on units The flexible corner unit is used for angled bends or to pass around or over an obstruction. The unit comprises a 1 metre length of 25mm flexible metal conduit and the appropriate 10mm 2 LSF cable STANDARD CLEAN EARTH 83 60 41.9 48 69 21.2 20.7 Tap-off unit Track Cable feed end DUAL TRACK 41.9 71 UPFCDE All dimensions in mm 72.4 124 32A TAP OFF UNIT l Standard Clean Earth Dual Track Minimum floor void 50mm 3M Unfused UPP3 UPP3TE UPP3DE 75 5M 13A Fused UPP5F UPP5FTE UPP5FDE 3.0m Unfused tap off wired with 4mm 2 LSF cable housed in a 1.6mm diameter flexible metal conduit 5.0m Fused tap offs incorporate a 13A Fuse and are wired with 2.5mm 2 LSF cable to Live and Neutral with the Earth wired using 4mm 2 LSF to comply with regulation 543.7 Tap off incorporates a keying system which ensures correct insertion is always achieved 83 96 Ctrs 83 Minimum floor void 73mm 71 48 UPP3 277 277

FLOOR BOX DISTRIBUTION The Britmac range of cable management products have been utilised in the design and installation of electrical systems in commercial and industrial projects for many years. The comprehensive fast-fit floor box provides a wide choice from which to select the most appropriate for a specific application. Units can be supplied fitted with accessories pre-wired to customers requirements and fully factory tested in the UK prior to delivery. The products are supported by a nationwide team of Sales Engineers and Stockists. Large capacity cable routing guides ensure cables exit the box safely and neatly Lid hinge design ensures that lid will always self-close Snap-out facility enables the lid to be removed for access to accessory plates Pre-wired saving time during site installation

3 COMPARTMENT FLOOR BOX & ACCESSORIES l TRIM COLOUR Grey GR03G The most popular size of raised access floor box for use in commercial office applications where power, voice and data services are required. Utilises 87mm wide accessory plates. For Floor Box Dimensions See page 204. 4 COMPARTMENT FLOOR BOX & ACCESORIES l TRIM COLOUR Grey GR04G Compact 4 compartment unit - utilises 66mm wide accessories. 4 compartment units can provide an attractive and economical solution for applications, where power, voice and data systems are to be accessed, particularly where both clean and utility power outlets are required or where more than one type of data system is required. For Floor Box Dimensions See page 204. GR03G GR04G GB3SRCD30/BG GB3SSN2/BG SWITCHED 13A SOCKETS l 13A 2 Gang switched socket Reg. 607 13A 2 Gang switched socket CLEAN EARTH 13A 2 Gang switched socket NON-STD Reg. 607 13A 2 Gang switched socket NON-STD CLEAN EARTH 13A 2 Gang switched safety socket 30mA 607 has dual earth terminals Clean Earth has a normal and an isolated earth. GB3SS2/BG GB3SS2CE/BG GB3SSN2/BG GB3SSN2CE/BG GB3SRCD30/BG GBSS2/BG GBSSN2/BG SWITCHED 13A SOCKETS l 13A 2 Gang switched socket Reg. 607 GBSS2/BG 13A 2 Gang switched socket CLEAN EARTH GBSS2CE/BG 13A 2 Gang switched socket NON-STD Reg. 607 GBSSN2/BG 13A 2 Gang switched socket NON-STD CLEAN EARTH GBSSN2CE/BG Power sockets supplied with rear entry terminals as standard. 607 sockets have dual earth system. Clean earth have a normal and an isolated earth. Only two 13A 2 gang Sockets can be fitted per Floor Box. UNSWITCHED 13A SOCKETS l 13A 2 Gang unswitched socket Reg. 607 13A 2 Gang unswitched socket CLEAN EARTH 13A 2 Gang unswitched socket NON-STD 607 has dual earth terminals Clean Earth has a normal and an isolated earth. GB3S2/BG GB3S2CE/BG GB3SN2/BG DATA AND COMMUNICATIONS l Plate to accept 4 LJU6C voice or 4 RJ45 data outlets Blank plate for on- site piercing Plate to accept 4x Alpha GBJ6C/BG GBBP/BG GBALPHA/BG Plate to accept 2x Euro modules GBEURO/BG (Will accept 4x Crabtree communication modules 25mm x 50mm). See page 23. All plates 66mm x 173mm. All accessory plates are supplied with fixing screws. GB3S2/BG GB3SN2/BG GBJ6C/BG GBBP/BG 13A accessory plates are supplied with the appropriate interior fitted. DATA AND COMMUNICATIONS l KNOCKOUT DIMENSIONS l GB3J6C/6BG GB32G/BG GB3J3/BG Accessory plate 4 knockout LJU6C/RJ45 GB3J6C/BG Accessory plate to accept 6x LJU6C/RJ45 GB3J6C/6BG Accessory plate to accept 2x 1G standard accessory GB3J3/BG Accessory plate to accept 2G standard accessory GB32G/BG Blank plate GB3BP/BG Accessory plate to accept 4x Alpha GB3ALPHA/BG Accessory plate to accept 2x Euro module GB3EURO/BG (Will accept 4x Crabtree communication modules 25mm x 50mm). See page 23. All plates 87mm x 173mm. All accessory plates are supplied with fixing screws. GBEURO/BG GBALPHA/BG LJU6C/RJ45 EURO ALPHA 36.6 50 47.6 22.2 50 23.7 GB3ALPHA/BG GB3EURO/BG

200013GY CURRENT RANGE l GROSVENOR LID REPLACEMENT 3 & 4 GANG Lid assembly, Grey 200013GY BRITMAC FLOOR DISTRIBUTION SYSTEMS Materials All systems are constructed from high quality materials and are designed to meet relevant British and International Standards including the installation requirements of the IEE Wiring Regulations. Trunking conforms with the requirements of BS 4678 Part 2: 1973 as applicable. Extensive use is made of pre-galvanised steel sheet and, where this is not appropriate, a hard-wearing epoxy polyester paint is used. GROSVENOR SPARES Trim piece (plain), Grey 98950-1/A/2 Raised Access Floors Throughout this catalogue the term Raised Access Floor has been used to describe any modular flooring system which is supported on adjustable pedestals providing a service void. Other names frequently used are Cavity Floor, False Floor, Platform Floor, Access Floor, Computer Floor, etc. 98950-1/A/2 98347-1/A/2 Trim piece (handle), Grey - Complete Cable flap, Grey Cable retainer, Black 98347-1/A/2 98351-1/H/1 98496-2/E/1 GROSVENOR FAST FIT RAISED ACCESS FLOOR BOXES GROSVENOR RAISED ACCESS FLOOR BOXES Floorboxes The Grosvenor floorbox has been designed to withstand working loads of the MOB PF2 PS/SPU March 1992 specification for raised floors. The floorboxes listed within this catalogue are capable of accepting a very wide range of accessories fitted in any compartment. However, certain combinations do impose restrictions on positioning, due to the clashes of connectors, plug tops or the cables themselves. All accessory plates are supplied complete with the appropriate thread cutting screws. Each fixing hole in the unit frames is unthreaded and deep plunged for ease of location of fixing. The minimum plug clearance between accessory plate and underside of floor is 34mm. Accessories In addition to the extensive range of standard accessories illustrated, many alternative items can be incorporated when specified. Typical items are listed below: 98351-1/H/1 98496-2/E/1 314 227 POWER Non-standard sockets. Clean Earth sockets. American NEMA sockets. Schuko and other European sockets. FLOOR GROMMET l In the modern office environment where flexibility is vital, the BRITACCESS floor grommet can accommodate most requirements for accessing cables on flexible conduits up to cable managed desks etc. If the requirement is for a basic access point the top element will satisfy that need. To allow a desk module to pass through from a floor void whether it be a 3 core flexible cable or a flexible conduit, the BRITACCESS grommet is suitable for the job. FLOOR ACCESS GROMMET l Top Grommet Only BAG150 214 (cut out) GR03 3 compartment GR04 4 compartment 300 (cut out) 34 87 TELEPHONE Components for most British Telecom, Mercury and other national and international systems. DATA A wide range of components to suit virtually all systems in current use. These include IBM, Wang, Phillips, ICL and many others. Provision can also be made for the accommodation of fibre optic installations and their components. All dimensions in mm Tolerance on cut-out dimensions is ±1mm ROTATING TOP COVER FLOOR ACCESS GROMMET (3 PART) 106mm 2 x 28mm Outlet Holes SPECIFICATION Top Element (Grommet Only) Dimensions: 37mm 150mm Hole 127mm Dia ±2mm 65mm O/A Diameter 150mm Internal Diameter 120mm Depth 65mm Material: High Impact ABS Colour: RAL 7016 SECURITY CLAMP MECHANISMS