MANUFACTURER DATA SHEET Analog I/O Module Manufacturer: Allen-Bradley/Rockwell Model Number: 1746-NI4 See www.geomartin.com for additional PDF datasheets Martin Part Number: E-014624-18 VendorPartNumber: AB # 1746-NI4 Chapters 4,5, 6 and Appendix B and C are being removed. PDF File: Doc_000002_Cover.pdf
This page is intentionally left blank
Allen-Bradley SLC 500 Analog I/O Modules (Cat. Nos. 1746-NI4, -NIO4I, -NIO4V, -NO4I, and -NO4V) User Manual
Important User Information Because of the variety of uses for the products described in this publication, those responsible for the application and use of this control equipment must satisfy themselves that all necessary steps have been taken to assure that each application and use meets all performance and safety requirements, including any applicable laws, regulations, codes and standards. The illustrations, charts, sample programs and layout examples shown in this guide are intended solely for purposes of example. Since there are many variables and requirements associated with any particular installation, Allen-Bradley does not assume responsibility or liability (to include intellectual property liability) for actual use based upon the examples shown in this publication. Allen-Bradley publication SGI-1.1, Safety Guidelines for the Application, Installation, and Maintenance of Solid-State Control (available from your local Allen-Bradley office), describes some important differences between solid-state equipment and electromechanical devices that should be taken into consideration when applying products such as those described in this publication. Reproduction of the contents of this copyrighted publication, in whole or in part, without written permission of Allen-Bradley Company, Inc., is prohibited. Throughout this manual we use notes to make you aware of safety considerations:! ATTENTION: Identifies information about practices or circumstances that can lead to personal injury or death, property damage or economic loss. Attention statements help you to: identify a hazard avoid the hazard recognize the consequences Important: Identifies information that is critical for successful application and understanding of the product. SLC, SLC 5/01, SLC 5/02, SLC 100, and SLC 500 are trademarks of Allen Bradley Company, Inc.
2 2 Quick Start Procedures 1. Check the contents of shipping box. Reference Unpack the shipping box making sure that the contents include: Analog I/O module (Catalog Number 1746- Series) user manual (Publication 1746-6.4) If the contents are incomplete, call your local Allen-Bradley representative for assistance. 2. Determine your power requirements for the modular controller. Reference Review the power requirements of your system to see that your chassis supports placement of the analog module. For modular style systems, calculate the total load on the system power supply using the procedure described in the SLC Installation & Operation Manual for modular style controllers (Publication Number 1747-6.2) or the SLC 500 Family System Overview (Publication Number 1747-2.30). For fixed SLC 500 controllers, refer to table 3.B on page 3 3. Chapter 3 (Installing and Wiring Your Analog Module) Appendix A (Specifications) Backplane Current External 24V dc Power Catalog Number Draw Supply Tolerance 5V (max.) 24V (max.) 1746-NI4 35 ma 85 ma NA 1746-NIO4I 55 ma 145 ma NA 1746-NIO4V 55 ma 115 ma NA 1746-NO4I 55 ma 195 ma 1746-NO4V 55 ma 145 ma 24 ±10% at 195 ma max. (21.6 to 26.4V dc) ➀ 24 ±10% at 145 ma max. (21.6 to 26.4V dc) ➀ ➀ Required for some applications. Publication 1746-6.4 January 1996
Quick Start 2 3 3. 3. Configure the module using the DIP switches (analog inputs only). Reference Each analog input channel can be configured for either voltage or current. Locate the DIP switches on your module and set them for your application. Chapter 3 (Installing and Wiring Your Analog Module) ON Configures channel for current input Off Configures channel for voltage input 1746-NI4 Current 1 234 O N Voltage Switch 1 = Channel 0 Switch 2 = Channel 1 Switch 3 = Channel 2 Switch 4 = Channel 3 1746-NIO4I, NIO4V Current 1 2 O Switch 1 = Channel 0 N Switch 2 = Channel 1 Voltage External 1746-NO4I, NO4V 24V dc Power Selector Sw 1 Backplane Publication 1746-6.4 January 1996
2 4 Quick Start 5.4. Install your module. Reference When selecting a slot for an analog module, position the module: in a slot away from ac or high voltage dc modules in the chassis closest to the bottom of the enclosure where the SLC 500 system is installed away from the chassis power supply if installed in a modular system Chapter 3 (Installing and Wiring Your Analog Module)! ATTENTION: Never install, remove, or wire modules with power applied to the chassis or devices wired to the module. Make sure system power is off; then insert the analog module into your 1746 chassis. In this example procedure, local slot 1 is selected. Top and Bottom Module Release(s) Card Guide Publication 1746-6.4 January 1996
Quick Start 2 5 8.5. Wire the module. Reference Important: Follow these guidelines when wiring the module. Use shielded communication cable (Belden 8761) and keep length as short as possible. Connect only one end of the cable shield to. Channels are not isolated from each other. All analog commons are connected together internally. The module does not provide power for analog inputs. Use a power supply that matches the transmitter (sensor) specifications. Chapter 3 (Installing and Wiring Your Analog Module) NI4 NIO4I & NIO4V NO4I & NO4V + analog source + analog source + analog source Load 24V dc power supply if external power is selected. Cable length from external 24V dc power supply to analog module must be less than 10m. Jumper unused inputs. Jumper unused inputs. Do not jumper unused outputs. Ext. pwr. sup. 0 1 2 3 4 5 6 7 8 9 10 11 0 1 2 3 4 5 6 7 8 9 10 11 0 1 IN 0 + IN 0 IN 1 + IN 1 IN 2 + IN 2 IN 3 + IN 3 IN 0 + IN 0 IN 1 + IN 1 not used OUT 0 not used OUT 1 +24V dc dc COM Load Load Analog commons are internally connected in the module. Channels are not isolated from each other. Do not jumper unused outputs. 0 1 2 3 4 5 6 7 OUT 0 OUT 1 OUT 2 OUT 3 Publication 1746-6.4 January 1996
2 6 Quick Start 9. 6. Configure system I/O configuration. Reference Configure your system I/O configuration for the particular slot the analog module is in. When assigning an I/O module to a slot location, select the module from the displayed list. If not listed, select OTHER at the bottom of the list and enter the module s ID code at the prompt. Chapter 4 (Module Operation and System Considerations) Catalog No. Module ID Code 1746-NI4 4401 1746-NIO4I 3201 1746-NIO4V 3202 1746-NO4I 5401 1746-NO4V 5402 10. 7. Check that the module is operating correctly. Reference! ATTENTION: Machine motion during system checkout can be hazardous to personnel. During all checkout procedures, you must disconnect all devices which, when energized, might cause machine motion. Chapter 5 (Testing Your Module) Apply power to the fixed or modular system. The analog module LED (red) should be illuminated, indicating that the module is receiving 24V dc power. Publication 1746-6.4 January 1996