SUNON SPECIFICATION FOR APPROVAL DESCRIPTION : DC BRUSHLESS FAN. DIMENSIONS : 60X60X15 mm M O D E L : KD0506PHS2



Similar documents
SUNON SPECIFICATION FOR APPROVAL

SPECIFICATION FOR APPROVAL

APPROVAL SHEET. Chip Coolers. Spire Corp.

Filterfans. Air Flow data: PF 1000 PF 2000 PF 2500 PF 3000 PF 5000 PF 6000 PF 7000

Once you know the volume of air and the static pressure of the system to be cooled, you can determine the fan specifications for your product.

POWER ROCKER SWITCH UL, CSA, VDE, TÜV, ÖVE, KEMA, SEMKO, NEMKO, DEMKO, FIMKO, SEV UL, CSA, VDE, TÜV, SEMKO, NEMKO, DEMKO, FIMKO, SEV, KEMA, ÖVE

Surface Technology. Centrifugal Fan GMD

- CONSTRUCTIONS 300 SECTIONAL VIEW 300 MECHANICAL SEAL DIMENSIONS AND WEIGHT 400 PUMP 400 PACKING 401

Miniatur Radial Gebläse mit integrierter Elektronik Miniature Radial Blower with integrated electronic

G7SA. Ordering Information. Slim Plug-In Safety Relay. Slim Safety Relay for Machine Control. H Slim body only 13 x 24 x 50 mm

Type Sealing Poles Contacts Rated voltage Model Standard d Flux-tight 4 poles oes 3PST-NO, SPST-NC 24 VDC G7SA-3A1B 3PST-NO, 3PST-NC

Application Information

PM734F - Technical Data Sheet Winding 28

Outer Diameter 23 φ mm Face side Dimension 20.1 φ mm. Baffle Opening. Normal 0.5 Watts Maximum 1.0 Watts Sine Wave.

AMP CO Plus Insert for Cat. 6 A Applications


Energy Saving ECM Motors and Fans Ventilation Catalogue

PI734D - Technical Data Sheet

PI734B - Technical Data Sheet

CDX. EBARA PUMPS EUROPE S.p.A. CENTRIFUGAL PUMPS. Page - CONTENTS 100

ECM Motors Manufactured By Regal Beloit. Products and Applications- What s an ECM? GEXPRO Regal Beloit s distribution arm for all ECM motor products

Telefon (+45) Telefax (+45) Installation and operating manual

Understanding Insulation Resistance Testing

SKR - industry relay

O-I DUBI PLANT FANS Quotation Spec Data & Specifications

Thermal-Magnetic Circuit Breaker M1-..

DRAIN PUMPS. Synchronous Drain Pumps DPS / DPO

DISCONTINUED (1998) FBR46 SERIES. MINIATURE RELAY 2 POLES 1 to 2 A (FOR SIGNAL SWITCHING) RoHS compliant FEATURES

SPST-NO SPDT DPST-NO DPDT

帝 聞 企 業 股 份 有 限 公 司 DEE VAN ENTERPRISE CO., LTD. SP DSL-20WA Revision: A Date: FOR AC-DC LED DRIVER MODEL NO.

MEMBRANE VACUUM MINI PUMPS

Basic Nameplate Information

pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2, /0.65/0.

8W! SILENT-100 Series. 26,5 db BATHROOM EXTRACT FANS. Bathroom and toilet extract fans SILENT-100. Low noise! Water protected! Energy efficient!

Fresh Air Enclosure Cooling Filter Fans

OPERATING MANUAL. Table of contents. 2 Phase Stepping Motor Driver 2M542. Rev. A. Introduction page 2. Specifications page 2 Timing chart page 3

O WA-120U series IP W Single Output Switching Power Supply. Features. Aplications

SIRIUX. SINGLE AND DOUBLE HIGH EFFICIENCY CIRCULATORS Heating Air-conditioning OPERATING LIMITS APPLICATIONS. 28 m 3 /h* Heads up to: Flows up to:

QPM3 Low pressure pump for circulation of oil in hydraulic and lubricating systems

SX460. Generator Automatic Voltage Regulator Operation Manual

Digital Ground Resistance Tester. Models 4620 & Digital Ground Resistance Tester

Two Position Cable-to-Board Power Connector System (Right Angle/Straight) with Coding Contacts

48 SERIES Relay interface modules 10 A

Technical Specification. Generating Set with Waukesha engine burning natural gas

VAQ. Built-in V-series Miniature Basic Switch for Compatibility with Business and Consumer Equipment. Pushbutton Switch (Cylindrical 10.5-dia.

Operating Temperature Range: -30 to +85ç (Note 1) Operating Humidity Range: 40 to 80%

How To Read A Pipe From A Sensor

8W! consumption. 26,5 db IP45. BATHROOM EXTRACT FANS SILENT-100 DESIGN 3C Series

Absolute Rotary Encoder E6CP

INSTALLATION AND MAINTENANCE INSTRUCTIONS FOR THREE PHASE INDUCTION MOTORS

Technical Concept. Filter Fan Unit COMPACT. Type COMPACT AC Type COMPACT EC

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

BASIS RANGE TMB SERIES

BCI184E - Technical Data Sheet

POWER RELAY. FTR-K1-KS Series. 1 POLE - 16A / Inrush 120A relay FTR-K1 SERIES FEATURES

Liquid Leakage Sensor Amplifier

Sierra Dual 24 Volt Brushless DC Motor Controller Product Specification

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

49 Series - Relay interface modules A. Features

REGULINE 600VA / 1000VA REGULATOR USER MANUAL

Motor Fundamentals. DC Motor

Unit 33 Three-Phase Motors

Single-Phase AC Synchronous Generator

I STAR COMPUTER CO., LTD

CRK A-W-A-BUBV

FASTERCNC CO,. LTD. FASTERCNC CO,. LTD.

Harmonic Drive acutator P r e c i s i o n G e a r i n g & M o t i o n C o n t r o l

Preset Counter signo 721

HB Hysteresis Brakes and MHB Matched Brakes

User s Manual Before using the inverter, you need to read and save the safety instructions.

SENSORS. Miniature Sensors - S3Z. Advanced line of miniature Asian style of photoelectric sensors mm background suppression

Rotating Machinery Diagnostics & Instrumentation Solutions for Maintenance That Matters

Brushless DC Motors Intro duction BLF BLU BLH Installation. Brushless DC Motors. DC Input. AC Input DC Input. BLH Series. Page. BLH Series B-52 B-51

SPEED CONTROL SYSTEM

C ole s quality Open Frame Instrument Rotary Switch provides low

BITMAIN. APW PSU Series User Guide

A S Y N C H R O N O U S M O T O R S

D.C. Motors. Products and specifications subject to change without notice.

PART 1 - INTRODUCTION...

CRN5-5 A-FGJ-G-E-HQQE 3x230/400 50HZ

MICRO SWITCH EJF SERIES

RY2 miniature industrial relays

I-PEX MHF4 Micro Coaxial Connector

HCM434F - Winding 311 APPROVED DOCUMENT. Technical Data Sheet

Relays High Capacity 50 Amp Mini Relays Standard Mini Relays Micro Relays Power Relays Connector Modules

DSD 70 Dual Channel Hall Effect Speed Sensor for Railway Applications, compliant with EN 50155

38 Series - Relay interface modules A

Compact Sensors - S8 Series. Compact size and high performance for the most challenging detection applications

TIG INVERTER INSTRUCTION MANUAL

Operating instructions

AZ420 MINIATURE GENERAL PURPOSE RELAY

Charge Regulator SCR 12 Marine

Filter Fan Unit SILENT. Type SILENT AC Type SILENT EC

3. ELECTRICAL PERFORMANCE PROPERTY TEST CONDITION PERFORMANCE 3. 1 Contact Resistance 1) Center Push 100mΩ Max

Chen. Vibration Motor. Application note

Automotive BL-DC Fans for Commercial Vehicles. Edition

Annex-A TECHNICAL SPECIFICATION

Certificate of Compliance

Fundamentals of Inverter Fed Motors

CRN A-F-G-E-HQQE 3x400D 50 HZ

Transcription:

SPECIFICATION FOR APPROVAL CUSTOMER : DESCRIPTION : DC BRUSHLESS FAN DIMENSIONS : 60X60X15 mm M O D E L : KD0506PHS2 APPROVED NO : APPROVED BY : (AUTHORIZED) SPEC.NO D600023 ISSUE DATE 08.06.1998 DAWN. Hui CHKD. APPD. 8/6 EDITION 0 REVISE DATE E.SPEC ED60074 SUNONWEALTH ELECTRIC MACHINE INDUSTRY CO., LTD. 12FL., 120 CHUNG CHENG 1ST RD., TEL:886-7-7163069(41 LINES) KAOHSIUNG, TAIWAN, R. O. C. FAX:886-7-7163086~89

DC BRUSHLESS FAN MODEL: KD0506PHS2 CHARACTERISTICS SUNON 1. Motor Design : Patented single-coil DC brushless 4 poles motor design. 2. Insulation Resistance : More than 500M ohm between internal stator and lead wire(+) measured by DC 500V. 3. Dielectric Strength : Applied AC 500V for one minute or AC 600V for 2 seconds between housing and lead wire(+) 4. Noise Level : Measured in an semi-anechoic chamber with background noise level below 15 db(a). The fan is running in free air with microphone at a distance of one meter from the fan intake. 5. Input power, Current & Speed : Measured after continuous 30 minutes operation at rated voltage in clean air at ambient temperature of 25 degrees C. 6. Tolerances : ±15% on rated power and current. 7. Motor Protection : Polarity protected & Locked rotor protected. 8. Air Performance : Measured by a double chamber. The value are recorded when the fan speed is stabilized at rated voltage. MACHINE INDUSTRY CO., LTD. P A G E 2 OF 6

SPECIFICATIONS MODEL: KD0506PHS2 1-1. Rated Voltage : 5 VDC 1-2. Operating Voltage Range : 4-6 VDC 1-3. Starting Voltage : 4 VDC 1-4. Rated Speed : 4000 RPM ± 400 RPM 1-5. Air Delivery : 17.8 CFM 1-6. Static Pressure : 0.135 Inch-H2O 1-7. Rated Current : 0.39 AMP 1-8. Rated Power : 1.9 WATTS 1-9. Noise Level : 31 db(a) 1-10. Direction of Rotation : Counter-clockwise viewed front fan blade 1-11. Operating Temperature : -10 to +70 Deg.C 1-12. Storage Temperature : -40 to +70 Deg.C 1-13. Bearing System : Lubricated sleeve bearing system 1-14. Weight : 45g 1-15. Safety : UL/CSA/TUV Approvals 1-16. Vibration : Vibration of acceleration 1.5G and Frequency 5~50~5Hz is applied in the 3 directions(x,y,z) for 30 minutes, each Direction at the cycle of 1 minute. MACHINE INDUSTRY CO., LTD. P A G E 3 OF 6

MODEL : KD0506PHS2 PERFORMANCE CURVES STATIC PRESSURE mm-h2o Inch-H2O 6 4 0.20 5 VDC 2 0.10 0 0 10 20 0 0.28 0.56 CFM m 3 /min MACHINE INDUSTRY CO., LTD. P A G E 4 OF 6

MATERIAL 2-1. Frame : Thermoplastic PBT of UL 94V-0 2-2. Impeller : Thermoplastic PBT of UL 94V-0 2-3. Bobbin : Thermoplastic PBT of UL 94V-0 2-4. Lead Wire : UL2468,26AWG,+RED;-BLACK DIMENSIONS Air Flow Direction: Label side. UNITS:mm MACHINE INDUSTRY CO., LTD. P A G E 5 OF 6

Notes 1. SUNON will not guarantee the products if the application of our products is exceeded the limitation which is specified on this specification. 2. In case of change of the specification specified on this document, a written notice is requested in advance. 3. Please do not touch the impeller with pressure and never bring the fan with lead wire. The bearings and lead wire may be damaged. 4. No guarantee on the products against the safety problem or failure caused by powder dust, drop of water or insect. 5. If there is any data or related documentation different from this data sheet, this data sheet is the principal reference. 6. For the purpose of MIS, please indicate SPEC No. on every order. 7. In case of the fan has no polarity protection function, wires with same color (electrode) must be connected together during the assembly. (i.e. red + red, black + black) or the fan will be damaged immediately. 8. Please do not use the fan in the environment of corrosive gas or liquid or any detrimental gas. 9. Please do not store the fan in the environment of high / low temperature, high humidity or any detrimental gas. Please store the fan within 6 months, every 6 months, there shall be a linkage of electric current to the fan, even though the fan is stored in room temperature. 10.While the fan is in operation, please do not lock the fan intentionally for a long period of time, since the continuous stoppage will result in over-heat and thus burn-out of the fan. 11.During the installation of the fan, please pay substantial attention to possible noise cause by resonance vibration and vibration. 12.During the testing of the fan, please be sure to use finger guard to insure safety. MACHINE INDUSTRY CO., LTD. P A G E 6 OF 6