Data sheet Thermostatic sensors type RA 2000



Similar documents
Data sheet Radiator Thermostats type RA 2000 Valve bodies type RA-FN and RA-G

Radio controlled, programmable radiator thermostat RA PLUS-w

Thermostatic Sensor RAS-C² with RA-FN Radiator Valve (Fixed Capacity)

Thermostatic Actuators

Thermostatic element RAVV for 2-way valves

Thermostatic actuator RAVV - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16)

Thermostatic actuator RAVK - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16) - for 3-way valves KOVM (PN 10), VMV (PN 16)

Thermostatic actuator RAVK - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16) - for 3-way valves KOVM (PN 10), VMV (PN 16)

Integrated Presetting Valves for Normal 013G0372 and Small 013G0373 Volume Flows

Thermostatic actuator RAVI - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16) - for 3-way valves KOVM (PN 10), VMV (PN 16)

Integrated Presetting Valves - for Normal Volume Flows RA-N and for Small Volume Flows RA-U

2-Port Self-acting Temperature Control Valve Selection for Heating and Cooling Applications

THERMOSTATIC ACTUATORS WITH LIQUID-FILLED SENSITIVE ELEMENTS AND TEMPERATURE LOCKING

Installers and specifiers seeking information and advice on radiator thermostats and their application will find no better source than Danfoss.

Valve range. To be precise.

PRODUCT PRODUCT CODE TECHNICAL INSTRUCTIONS PAGE

E v e r i n c r e a s i n g i n n o v a t i o n. R A R a n g e. C o m m e r c i a l T R V s

Data sheet ECC 12 and 22

HERZ-Thermal Actuators

Thermostats. Technical information

Low-H2O valves Y EARS

Radiator valve accessories

MAKING MODERN LIVING POSSIBLE. Thermostatic valve AVTA. Technical brochure

Selection Chart T-4000 Series Accessories (Part 1 of 5) Code Number Figure Description Application (High or Low Volume)

Digital inductive conductivity transmitter

Self-operated Temperature Regulators Temperature Regulator Type 1u

Automatic Bypass Control AVDO

Powers Controls TH 192 S Single Temperature Room Thermostat

MAKING MODERN LIVING POSSIBLE. living connect. Installation and User Guide. Danfoss heating

REGULATORS 175/153 Series

RADIATOR VALVES / MANIFOLD ASSEMBLIES AND DIVERTERS

MAKING MODERN LIVING POSSIBLE. living connect. Installation and User Guide. Danfoss Heating Solutions

Thermostatic valve Type AVTA

Powers Controls TH 192 HC Heating/Cooling Room Thermostat

Technical catalogue convectors POLAND 2012

Comfort Compact Controller ZG 215N

1. Taboe Sani 2. Taboe 3. Taboe Freestanding

EMO T. Thermal actuator for heating, ventilation and air conditioning systems

Thermostatic expansion valves type TR6 REFRIGERATION AND AIR CONDITIONING. Technical leaflet

1. Geo Vertical 2. Geo Horizontal

RVL470. Heating Controller. Building Technologies HVAC Products. Series B

Technical Guide. Thermostats Air Conditioning

STABITHERM INSTALLATION & SERVICE BOOKLET

Floor Heating Warehouse.co.uk

Frequently Asked Questions

Solenoid valves Type EVU

Operators manual Basic water heater

CAST IRON THE BASICS. Heatline - Cast Iron Radiators SMOOTH FLAT FILE TO REMOVE ANY SWARF. ONE TIME. ASSEMBLY. JOINTS SHOULD BE TIGHTENED.

GB/DAS User Instruction

COMMERCIAL GAS DRYER

Solenoid valves 2/2-way direct-operated Type EV210A

SHOWER WATER HEATER MODEL BS 35 / 45 / 60 BS 35 E / 45 E / 60 E OPERATION AND INSTALLATION INSTRUCTIONS

TOBY DVR5 OIL CONTROL & SAFETY VALVE

ECOSTYLE RADIANT PANELS Installa on and Opera on Manual 2013

COMMERCIAL GAS DRYER

INSTRUCTION MANUAL HYDRAULIC GATE TRANSMISSION SYSTEM ECO240-ECO360

1. RANGE OF APPLICATION 3. SAFETY INSTRUCTIONS 4 4. DESIGN 4

Powers Controls Free Energy Band TH 193 HC Heating/Cooling Room Thermostat

1 DESCRIPTION OF THE APPLIANCE

Flow controller with integrated control valve (PN 16, 25, 40*) AFQM, AFQM 6 - return and flow mounting

ES-LCD User Control SD Card Location

Assisted lift operated 2/2-way solenoid valves Type EV250B

Specifications. Model Flow type Pressure type. Air Maximum operating pressure. 1.0 MPa Ambient and fluid temperature. 3% F.S.

Product and Application Description

SIBIR MANUAL V110 KE. English page 5 RKE - 1D

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

TP5000 Si Range Electronic 5/2 day programmable room thermostat Mains, Battery and RF versions Installation and User Instructions

ECL Comfort 110 Application 130. Weather compensated flow temperature control of heating and boiler systems. Instructions

AN500T, AN1000, AN1000T, AN1500, AN1500T AN2000, AN2000T

Pressure switches and thermostats, type KPS

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

Commercial Gas Cooking Thermostats

POWERS CONTROL RC 195 Single Input Receiver-Controller

NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

Your safety and the safety of others are very important.

T5000 T000 LCD Digital Fan Coil Thermostat

Typical Aluminum GFM Mass Flow Meter

Heat Pump Training System

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

SET-UP AND INSTALLATION FOR LEAD SCREW CARTRIDGE ASSEMBLY

Automatic balancing valves ASV

Smile. The All-In-One Heating Controller

REMOVAL AND INSTALLATION

Heating Controller. Building Technologies HVAC Products

I nstallation. M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications. Tools Needed.

For installation guide see reverse of book

Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS

COMMERCIAL GAS DRYER

Isotemp Basic, Slim/B & Slim Square

How To Use A Power Supply On A Powerline 2.2 (Ai)

Programmable Room Thermostat 7 Day (5-2 Day) Models: / Power Supply: Battery / Mains

Directory chapter 02 - DIN Power (to 6 A) Types D, E, F, FM, 2F, F9, interface connectors I/U Technical characteristics types D and E

Operating Instructions Bedienungsanleitung Mode d emploi

stainless steel pre-assembled manifolds

CONTENTS 1. IMPORTANT NOTICE 2 2. TECHNICAL SPECIFICATION 3 3. OPERATION DETAILS 4 4. WIRING DIAGRAM EXPLOSION VIEW 12 6.

JANUS INTERNATIONAL CORPORATION INSTALLATION INSTRUCTIONS Pantheon Mini Operator

Overview - Danfoss Link and living software versions

AFE424 SERVICE PARTS

Building Technologies. Thermostats and room controllers. General Product range overview Thermostats

Transcription:

Thermostatic sensors type RA 2000 EN 215-1 RA 2990 RA 2992 RA 2920 RA 5060 RA 5074 Application The RA series is a comprehensive programme of radiator thermostats which covers all central and district heating systems. RA is a self-actuating proportional controller with a small P-band. The RA sensor range includes: RA 2990 and RA 2940: built-in sensor with frost protection, temperature range 5-26 C, facilities for limiting and locking the temperature set-point. RA 2980 has an additional anti-theft facility. RA 2940 has positive shutt off feature. RA 2992: remote sensor with frost protection, temperature range 5-26 C, facilities for limiting and locking the temperature set-point. RA 2982 has an additional anti-theft facility. RA 2920: Tamperproof model with built-in sensor, frost protection, temperature range 5-26 C, facilities for limiting and locking the temperature set-point. RA 2922: Tamperproof model with remote sensor, frost protection, temperature range 5-26 C, facilities for limiting and locking the temperature set-point. RA 2992 and 2922 are equipped with 2 m of ultra-thin capillary tube, which is coiled up within the remote sensor housing. After sensor mounting capillary tube is pulled out to the required length. RA 5060/5070 Series: remote temperature adjuster with frost protection. Temperature range 8-28 C, facilities for limiting and locking the temperature set-point. - RA 5062: length of capillary tube 2 m - RA 5065: length of capillary tube 5 m - RA 5068: length of capillary tube 8 m - RA 5074: length of capillary tube 2 + 2 m All thermostatic sensors can be combined with all RA 2000 valve bodies. A union nut establishes a simple but strong connection between sensor and valve body. Anti-theft protection prevents the sensor from unauthorised removal. (See accessories). The technical data for RA valve bodies in combination with RA sensors meet Euronorm EN 215-1. Ordering and specifications RA thermostatic sensors Type Code no. Model Cap. tube Temp. range 2) RA 2940 013G2940 Standard, built-in sensor, positive shut off - 0-26 C RA 2990 013G2990 Standard, built-in sensor - 5-26 C RA 2992 013G2992 Standard, remote sensor 0-2 m 1) 5-26 C RA 2920 013G2920 Tamperproof, built-in sensor - 5-26 C RA 2922 013G2922 Tamperproof, remote sensor 0-2 m 1) 5-26 C RA 5062 013G5062 Remote temperature adjuster 2 m 8-28 C RA 5065 013G5065 Remote temperature adjuster 5 m 8-28 C RA 5068 013G5068 Remote temperature adjuster 8 m 8-28 C RA 5074 013G5074 Remote adjuster with remote sensor 2 + 2 m 8-28 C 1) The remote sensor is delivered with all of the capillary tube coiled up within the sensor. When mounting the sensor, only the capillary tube required is uncoiled. 2) Temperatures stated for Xp = 2K, i.e. the valve is closed at 2 C higher room temperature. DKCD VD.51.A5.02 Danfoss 1/2007 1

Thermostatic sensors type RA 2000 Accessories Product Manual setting knob for RA valves, plastic Manual setting knob for RA valves, brass Limiting pins for RA 2990/92 (30 pcs.) Limiting pins for RA 2920/22 (30 pcs.) Anti-theft plugs for RA 2990/92 (20 pcs.) Scale cover for RA 2920/22 (20 pcs.) Toolkit, Allen key & locking pin tool Compact adaptor for RA 5062/65/68 to RA 2000 valves Adaptor for RA 5062/65/68 to RA 2000 valves Adaptor for RA 5062/65/68 to RAVL valves Adaptor for RA 5062/65/68 to RAV valves Code no. 013G5002 013G3300 013G1246 013G1237 013G5245 013G1672 013G1236 013G5190 013G5191 013G5192 013G5193 Setting the temperature The required room temperature is set by turning the setting dial. The temperature scales show the correlation between scale values and the room temperature. The temperature values stated are for guidance only as the obtained room temperature will often be influenced by installation conditions. The temperature scales are stated according to European standards at Xp = 2 C. This means that the radiator thermostats close at a sensor temperature which is 2 C higher than stated on the temperature scales. Locking and limitation of the temperature set-point of RA sensors are carried out using the limiter pins placed at the back of the sensor. Locking and max./min limitation of the remote temperature adjuster type RA 5060 are carried out by the limiter tabs. The limiter tabs will be covered by the setting dial. The procedure is described in the instruction. = Frost protection setting * 7 9,5 14 17 20 23 26 28 C l * 1 2 3 4 5 l RA 2990 /92 RA 2920/22 5 7,5 13 15 18 21 24 26 C RA 5062, RA 5065, RA 5068, RA 5074 * 10 14 18 22 26 30 C * 1 2 3 4 5 8 12 16 20 24 28 C = Frost protection setting Mounting 2 VD.51.A5.02 Danfoss 1/2007 DKCD

Thermostatic sensors type RA 2000 Choose the right sensor The thermostatic sensor should be selected on the basis of the following criteria: The sensor must always be able to register the temperature of the ambient air. Radiator thermostats with built-in sensors These should always be fitted horizontally so that the ambient air can pass freely over the sensor. Danfoss does not recommend the fitting of a built-in sensor in vertical position because heat effect from the valve body and possibly surface pipes will cause incorrect operation of the thermostat. Radiator thermostats with remote sensor These should be used when: - Curtains cover the sensor - Sensor is affected by surface pipes - Sensor is affected by draught - It is necessary to mount the sensor in vertical position if there are adjacent obstructions. The remote sensor must be mounted on the wall, away from curtains, or on the skirting board beneath the radiator if free of surface pipes. All remote sensors are now supplied with ultra-thin capillary tube. Simply pull out the length required (2 m maximum) and fix using clips provided or special tacker gun. Radiator valves with remote adjustment The remote temperature adjuster is used on radiators or convectors which are hidden in a cabinet or in other ways inaccessible to the user. In addition, the room temperature adjuster is used in integral sockets and installation ducts. The sensor and the setting part of a remote setting unit are integrated. The remote temperature adjuster is placed in an easily accessible place where the ambient air can at the same time pass freely over the sensor. This is ideal where the valve is inaccessible to the user. The temperature adjuster should be mounted between 1.2 and 1.6 m above the floor. DKCD VD.51.A5.02 Danfoss 1/2007 3

Thermostatic sensors type RA 2000 Sensor operation principle 1. Actuator 2. Bellows 3. Setting dial 4. Setting spring 5. Spindle 6. Remote sensor 7. Capillary tube 1. Actuator 2. Setting part 3. Setting bellows 4. Operation bellows 5. Valve adaptor 6. Capillary tube, rolled up 1 2 3 4 5 6 1. Valve adapter 2. Actuator 3. Setting bellows 4. Capillary tube, rolled up 5. Setting part 6. Capillary tube, rolled up Max. ambient sensor temperature: 60 C. 4 VD.51.A5.02 Danfoss 1/2007 DKCD

Dimensions Standard model RA 2990 Model with remote sensor RA 2992 Tamperproof model RA 2920 Remote temperature adjuster with adaptor for RA 2000 Adaptor for RAVL og RAV valve bodies (accesories) 35,6 Remote temperature sensor for RA 5074 DKCD VD.51.A5.02 Danfoss 1/2007 5

6 VD.51.A5.02 Danfoss 1/2007 DKCD

DKCD VD.51.A5.02 Danfoss 1/2007 7

8 VD.51.A5.02 Danfoss 1/2007 DKCD