GeneXpert Technology. Indira Soundiram 2012



Similar documents
Mobile Lab-Diagnostik

Epstein Barr Virus (Human Herpes virus 4) nonglycosylated membrane protein (BNRF1) gene. genesig Advanced Kit. DNA testing

Epstein Barr Virus (Human Herpes virus 4) genesig Standard Kit. DNA testing. Everything... Everyone... Everywhere...

Human Herpes Virus 4 (Epstein Barr)

Genomic DNA detection assay

Validating Microarray Data Using RT 2 Real-Time PCR Products

Quantifiler Human DNA Quantification Kit Quantifiler Y Human Male DNA Quantification Kit

Human Herpes Virus 1 (Herpes simplex type 1) genesig Standard Kit. DNA testing. Everything... Everyone... Everywhere...

Dengue Virus subtypes 1,2 3 and 4. genesig Standard Kit. DNA testing. Everything... Everyone... Everywhere... 3 Untranslated Region (3 UTR) 150 tests

Factors Influencing Multiplex Real-Time PCR

HBV Quantitative Real Time PCR Kit

User Manual. CelluLyser Lysis and cdna Synthesis Kit. Version 1.4 Oct 2012 From cells to cdna in one tube

HBV PCR detection Kit USER MANUAL

Quantification of Mycobacterium Tuberculosis. 150 tests

Real-Time PCR Vs. Traditional PCR

ncounter Gene Expression Assay Manual Total RNA and Cell Lysate Protocols

Lyme Disease. RecA gene. 150 tests. Quantification of Lyme Disease genomes. Advanced kit handbook HB

Hepatitis B Virus. genesig Advanced Kit. DNA testing. Everything... Everyone... Everywhere... Core Protein Region. 150 tests.

Co Extra (GM and non GM supply chains: Their CO EXistence and TRAceability) Outcomes of Co Extra

Real-time quantitative RT -PCR (Taqman)

TaqMan Fast Advanced Master Mix. Protocol

BacReady TM Multiplex PCR System

RealLine HCV PCR Qualitative - Uni-Format

Lyme Disease RecA gene. genesig Advanced Kit. DNA testing. Everything... Everyone... Everywhere tests. Primerdesign Ltd.

SYBR Green Realtime PCR Master Mix -Plus-

Genomic DNA Extraction Kit INSTRUCTION MANUAL

Path-ID Multiplex One-Step RT-PCR Kit

Optimizing and Analyzing Real-Time Assays on the SmartCycler II System

CRE. BD MAX CRE Assay REF For Research Use Only (RUO). Not for use in diagnostic procedures

RealStar HBV PCR Kit /2012

Borrelia burgdorferi

GenScript BloodReady TM Multiplex PCR System

Protocol. Introduction to TaqMan and SYBR Green Chemistries for Real-Time PCR

Streptococcus pneumoniae

ab Hi-Fi cdna Synthesis Kit

Mitos P-Pump. product datasheet

Quantification of Hepatitis B Virus. Core Protein Region. 150 tests

Introduction To Real Time Quantitative PCR (qpcr)

MystiCq microrna cdna Synthesis Mix Catalog Number MIRRT Storage Temperature 20 C

Quantification of Propionibacterium acnes. Standard kit 150 tests

altona altona RealStar Clostridium difficile PCR Kit 1.0 always a drop ahead. 11/2012 altona Diagnostics GmbH Moerkenstr Hamburg Germany

RT rxns. RT rxns TRANSCRIPTME Enzyme Mix (1) 40 µl 2 x 50 µl 5 x 40 µl

FastLine cell cdna Kit

HISTO SPOT SSO System

Beginner s Guide to Real-Time PCR

Table of Contents. I. Description II. Kit Components III. Storage IV. 1st Strand cdna Synthesis Reaction... 3

DNA Sequence Analysis

BD Affirm VPIII. Microbial Identification System

Application Guide... 2

SEQUENCING. From Sample to Sequence-Ready

TIANquick Mini Purification Kit

Essentials of Real Time PCR. About Sequence Detection Chemistries

Klebsiella oxytoca. Outer membrane protein II (ompa) gene. 150 tests. Quantification of Klebsiella oxytoca genomes. Advanced kit handbook HB10.03.

Single Nucleotide Polymorphisms (SNPs)

PreciseTM Whitepaper

quantitative real-time PCR, grain, simplex DNA extraction: PGS0426 RT-PCR: PGS0494 & PGS0476

PCR and Sequencing Reaction Clean-Up Kit (Magnetic Bead System) 50 preps Product #60200

Fluorescent dyes for use with the

ID kit. imegen Anchovies II. and E. japonicus) DNA detection by. User manual. Anchovies species (E. encrasicolus. sequencing.

First Strand cdna Synthesis

Technical Manual No Update Date

AmpliSens Toxoplasma gondii-frt PCR kit

Protocol v001 Page 1 of 1 AGENCOURT RNACLEAN XP IN VITRO PRODUCED RNA AND CDNA PURIFICATION

PCR Instruments and Consumables

The GeneAmp PCR System Results you can trust. A PCR platform you can grow with. GeneAmp. PCR System 9700

Recommended Procedures for the Extraction of RNA. Jan Pedersen USDA, APHIS, VS, National Veterinary Services Laboratories, Ames, IA 50010

Why Being Small? Savings in time & cost. Disposable Parallel processing Integration/Automation. Gain from the unique microscopic features

Quando si parla di PCR quantitativa si intende:

UltraClean PCR Clean-Up Kit

ABSTRACT. Promega Corporation, Updated September Campbell-Staton, S.

510(k) SUBSTANTIAL EQUIVALENCE DETERMINATION DECISION SUMMARY

Maxwell 16 Blood DNA Purification System

ncounter Leukemia Fusion Gene Expression Assay Molecules That Count Product Highlights ncounter Leukemia Fusion Gene Expression Assay Overview

Gene Expression Assays

BD MAX. System User's Manual

DNA Integrity Number (DIN) For the Assessment of Genomic DNA Samples in Real-Time Quantitative PCR (qpcr) Experiments

Biologic Air-Borne Particle Detection, Sampling, and Identification

Discover Cell-specific Genomics Arcturus PixCell IIe Laser Capture Microdissection System and RNA Isolation / Amplification Kits

HISTO SPOT SSO System. The most convenient automated HLA typing system. BAG Health Care the experts for HLA and blood group diagnostics

FULLY AUTOMATED AND VALIDATED HIGH VOLUME DNA EXTRACTION USING CHEMAGEN MAGNETIC BEADS BASED KITS

Speed Matters - Fast ways from template to result

QuantiFast Multiplex PCR Handbook

RNA Extraction and Quantification, Reverse Transcription, and Real-time PCR (q-pcr)

Application Note. Single Cell PCR Preparation

LightCycler 480 Real-Time PCR System

Molecular Assessment of Dried Blood Spot Quality during Development of a Novel Automated. Screening

Reconstituting and Diluting Primers and TaqMan Probes

MagExtractor -Genome-

PNA BRAF Mutation Detection Kit

REAL TIME PCR USING SYBR GREEN

Absolute Quantitation Using Standard Curve Getting Started Guide

Terra PCR Direct Polymerase Mix User Manual

History of Innovation

Melissa May. NetBio - Vice President Strategic Planning. Date: 22/10/2013

Automation in genomics High-throughput management of biological samples and nucleic acids. Valentina Gualdi Operational Scientist PGP

Six Trends in Robotics in the Life Sciences

Automated Nucleic Acid Extraction WorkStation Faster, cleaner,

Transcription:

GeneXpert Technology Indira Soundiram 2012

A Better Way to Platform Design GeneXpert Infinity-48 GeneXpert Module GX-I GX-II GX-IV GX-XVI 2

Defining Molecular Diagnostics Any Test Any Time Any Sample Any Place The GeneXpert Family of Systems GeneXpert Module ICORE Module SmartCycler System SmartCycler Tube GeneXpert Cartridge 3

Delivering A Better Way Delivering a Better Way to Realize the Benefits of Molecular Diagnostics ACCURATE Results FAST Answers EASY To Use 4

GeneXpert Dx System Components GeneXpert System includes: Modules Thermal and optical system Cartridge Self-Contained Disposable Computer System Software Barcode scanner Optional Accessories Printer UPS 5

GeneXpert Technology Integrated micro-fluidic based system comprised of Instrument platform Cartridges Protocols and Controls 6

GeneXpert Technology Employ random access fluidic systems that bridge microfluidics with macro fluidics Uses multiplex, rapid real-time PCR technique (6-colors) Precision of microfluidics-based reconstitution, and simplification of automated filling Exploits proven SmartCycler technology (Incorporate same solid-state thermal cycler/fluorometer module) Utilize families of cartridges to address wide range of applications and specimen types 7

GeneXpert Design Approach No wet interface between instrument and cartridge to eliminate carry-over Integrated ultrasonic horn for rapid lysis of spores Total internal control of reagent system No separate external positive or negative controls required Smart fluidics Encoded software driven motors for valve movement and integral hydraulic drives Advanced micro fluidics technologies to enable complex sample prep processing protocols (many milliliters down to 10 micro liters) Automated data reduction and results interpretation 8

Cepheid Technology GeneXpert Washing DNA/RNA extraction DNA or RAN purification Patient Sample SmartCycler MasterMix Positive Négative Analysis Detection Amplification 9

Automated Xpert MTB/RIF Protocol in less than 2h 7. View/print results about 50 minutes later! 10

Platforms SmartCycler Instrument I-CORE module GeneXpert Instrument GX module 11 BDS

The I-Core Module Building Block of the Smart Cycler and GeneXpert 12

GeneXpert I-Core module Excitation & Detection 13

A micro lab: GeneXpert module + the cartridge Syringe Motor Motherboard I-CORE + Processing Chambers Reaction tube Module Door Valve Drive Motor Valve Body 14

Cepheid Technology GeneXpert SmartCycler 15

Cepheid Cartridge Syringe drive I-CORE Valve drive Ultrasonic horn 16

GeneXpert Module Motherboard Syringe Motor Uniframe I-CORE Cartridge Inserter Valve Drive Motor Ultrasonic Horn 17

Inside Chamber Syringe drive shaft ICORE tube insertion ¾ inches Valve drive (wedge) Ultrasonic horn 18

GeneXpert Cartridge GX cartridge has 11 chambers Lower numbered chambers are used for sample processing Higher numbered chamber are used for reagents There are basically two types of cartridges Cartridge A Pre-filter or Funnel Cartridge A only Cartridge C Both cartridge A and C has identical body construction. Only difference is the bottom part 19

Cartridge Side View 20

Cartridge Exploded View PCR Tube Ports for PCR tube Cartridge Body (11 Fluid Chambers and overmolded gasket) Valve body Ports.. Syringe Barrel Rotary Valve/Filter and Ultrasonic Lysis or SPB Region Cap/Ultrasonic Interface Cartridge Foot 21

Cartridge Valve Body Types Cartridge A Cartridge C 22

Cepheid Assay Control Strategy Each GeneXpert cartridge is a self-contained unit test device The use of external controls will have limited use in assuring proper assay performance Cepheid designed specific molecular methods to include internal controls that enable the system to detect specific failure modes Three elements of the molecular design were created to address all the key failure modes that could result in a false negative result Probe Check Specimen Processing Controls 23

Probe Check What is it? Just prior to starting thermal cycling, multiple fluorescence readings at different temperatures are made. The results are automatically compared to pre-established factory settings in the software. What does it do? Probe check verifies Bead re-hydration PCR tube filling Probe integrity Dye or quencher instability 24

Sample Processing Control (SPC) Intact organisms, DNA or RNA What is it? Detection probe: A fluorescently-labeled hybridization probe with different color reporter dye than that of the target probe(s) or the internal control (IC); present in primer-probe bead Primers: Can be the same as those for the target or IC or can be unique; present in primer-probe bead What does it do? Co-processed with target organism through entire sample prep process Co-amplified with targets - The SPC assesses the effectiveness of the sample processing steps, including and up to reaction tube filling - Detects degradation of enzyme(s) or other components of system - Detects sample inhibition 25

Regular Real-Time PCR Assay DNA Positive Control (PC) - Assay Run control Verifies reagent integrity DNA Negative Control (NC) - Assay Run control Detects environmental or reagent contamination and verifies reagent integrity. Internal control (IC) Tube control Detects PCR inhibition and verifies reagent integrity. Does not compete with target DNA. 26

GeneXpert Real-Time PCR Assay DNA Positive Control (PC) - Assay Run control ProbeCheck DNA Negative Control (NC) - Assay Run control No need! No wet interface between instrument and cartridge and 1 cartridge for 1 sample! Internal control (IC) Tube control Better : SPC, not only amplification but extraction too Does not compete with target DNA. 27

SPC does not compete with target DNA 28

SPC does not compete with target DNA SPC must be Positive when the Target is Negative SPC can be Positive or Negative when the Target is Positive 29

Interpretation of Results Pass Probe Check Fail Test Stopped No Value Target Error Pos No Value Positive SPC IC Pos Negative No Value Invalid 30