instabus KNX / EIB System System E F G H



Similar documents
is then retained absolutely without interruption.

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

Emergency lighting units EM powerled

Modular I/O System Analog and Digital Interface Modules

Safety technique. Emergency stop module BO 5988 safemaster

DALI RC BASIC SO. Control unit Operating instructions

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

PCS0100en Persy Control Services B.V. Netherlands

Product and functional description

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in

Smoke and Heat Vent Control Unit A

ST Series POWER SUPPLIES USER INSTRUCTIONS

How To Use A Power Supply Unit (Upu)

mecotron Safety relay ESTOP-2 For emergency stop monitoring

Operating instructions Diffuse reflection sensor. OJ50xx / / 2004

ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG R0011

Thyristor-controlled power supplies and battery chargers

ABB i-bus KNX SA/S Switch Actuators Product Manual

Fire Alarm Control Panel. Family. Operating Manual

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

LINETRAXX VMD460-NA. Network and system protection (NS protection) for monitoring the power feed-in of power generation systems

Shutter Actuator Standard, 4-fold, 230 VAC, MDRC RA/S , GH Q R0111. ABB i-bus EIB

Voltage Regulator SPAU 341 C. Product Guide

Preset Counter signo 721

MANUAL D250S DUAL. Solar panel + Vehicle ground/solar panel

Quick Connect. quick - simple - efficient.

PHOENIX CONTACT - 01/2007

Mobile Data Power Model: MDP-25

PUSH BUTTON START INSTALLATION MANUAL

CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems

*.ppt 11/2/ :48 PM 1

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Electrical connection

VEO. V4PF480Y/277VSYTK02 Art.Nr.: V4PF480Y/277VSYTK02P Art.Nr.: TECHNICAL DATA

ANTI-THEFT SYSTEM Volvo 850 DESCRIPTION & OPERATION BASIC ALARM ACCESSORIES & EQUIPMENT Volvo Anti-Theft Systems

FIREDEX Conventional Fire Panels

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

ACS-30-EU-EMDR-10-MOD

DEK-REL- 24/1/SEN. Extract from the online catalog. Order No.:

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT Spur 2. Spur 1. Zone 1. Zone 0

UM-X Field display for continous level sensors

48 SERIES Relay interface modules 10 A

Electronic overload relay EF19 and EF45

USER S MANUAL. MaxPower UPS. Uninterruptible Power System 28-2MAXPO0018

MANUAL. * Supply plugs may differ to suit your wall socket. EN 3. Continue to press the MODE-button to combine charging program with charging options.

Light scene push button 8gang comfort flush-mounted xx

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories

Push button 3gang standard flush-mounted xx

HERZ-Thermal Actuators

MINI MCR-SL-R-UI(-SP)

ALARM ANNUNCIATOR ME INSTRUCTION MANUAL

13 SERIES. Electronic step relays A

Instruction Bulletin. MCS025 Sync-Check Module Installation Sheet

MONITORING RELAYS. w VOLTAGE MONITORING RELAY UR5U1011. w SCHRACK-INFO. w TECHNICAL DATA

TMS TANK MANAGEMENT SYSTEM

HAM841K ALARM CONTROL PANEL FOR COMMERCIAL AND RESIDENTIAL SECURITY SYSTEMS

ABB i-bus EIB Shutter Actuators JA/S , JA/S , JA/S , JA/S M, JA/S M, JA/S

PSU-U-24V/AC-6A/10/FTA-TR-MC PSAC 0624

Electronic overload relay EF65, EF96 and EF146

BARDIC. 4 & 8 Zone Fire Panels Zircon range. Data, installation, operation and maintenance. by Honeywell

Photovoltaic Solar Energy Unit EESFB

EN 3 ABSORPTION, READY TO USE ANALYSE BULK DESULPHATION SOFT START. L: 2000 mm MODE- BUTTON SUPPLY PLUG* SUPPLY

User s Manual Before using the inverter, you need to read and save the safety instructions.

15 Series - Electronic step relay and dimmer. Features SERIE

INSTALLATION MANUAL. SAILOR 5080 AC Power Supply

ABB i-bus KNX Security Terminals MT/U , MT/S M and M Product Manual

Operating Manual for the Electronic Built-in Interval Timer. Micro II (Countdown Timer)

ADM1TE 5/30A DIN rail single phase two wire energy meter

SYSTEM 4C. C R H Electronics Design

Thermistor motor protection

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

Residential Gateway (RG) Battery Backup

ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01

Emergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN , VDE 0113 Part 1

1. Connect the charger to the battery. 2. Connect the charger to the wall socket. 3. Press the MODE-button to select charging program.

1 Safety instructions. 2 Device components. 3 Function. Leader in Led solutions. Compact presence detector. Operating instructions

ML 1012 v.1.2 ML13,8V/1A Buffer power supply module, linear.

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

ABB i-bus KNX Switch Actuator, x-fold, 16 A, MDRC SA/S x , 2CDG1101xxR0011

DRM75A 230V 20/100A DIN rail single phase two wire energy meter

Solar Home System. User Manual. AEH-SHS01-10W2L Solar Home System 2 Lamps

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

IO-RM3 3-Stage Relay Module

Safety Relays ESM/ESM-F

PERCEDOS. Instruction Manual/Technical Information PERCEDOS

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

WxGoos-1 Climate Monitor Installation Instructions Page 1. Connections. Setting an IP Address

Charge Controller CC611/CC612 Preliminary datasheet

victron energie USER MANUAL GEBRUIKSAANWIJZING GEBRAUCHSANWEISUNG Victron Atlas 12/850

MANUAL EN 3 SUPPLY PLUG* MAINS CABLE CTEK COMFORT CONNECT ABSORPTION, READY TO USE ANALYSE FLOAT, FULLY CHARGED PULSE, MAINTENANCE CHARGING

HM-W536 Install Guide

PC INTERFACE MODULES FOR TOLL-PLAZA CLASSIFICATION SENSORS

3RT1015-1BB41 CONTACTOR, AC-3 3 KW/400 V,

Your automation should be permanently supplied Our compact PROeco power supplies offer that as part of an economical concept Let s connect.

Transcription:

Product name: Uninterruptible power supply (USV) 640 ma Design: REG (rail-mounted device) Article-no.: 1079 00 ETS search path: Gira Giersiepen / system components / power supply / power supply 640mA DRA uninterruptible Scope of application: The uninterruptible KX/EIB power supply 640 ma (USV) generates and monitors the KX/EIB system voltage. The power supply is designed to ensure the interruption-free supply of max. 64 bus devices (1 line) directly via the integrated choke and is therefore suitable for use especially in KX/EIB security systems. The device is connected to the system by means of the bus connecting terminal at the front of the device (no data rail required). The bus output is overload- and short-circuit-protected in acc. with the KOEX specification and offers protection against overvoltage. The KX/EIB voltage can be buffered with a 12 V DC gelled lead-acid storage battery which is connected to the device by means of a pre-assembled 4-wire connecting cable. When the mains voltage is on, the storage battery is recharged via the uninterruptible power supply in a temperature-controlled mode. In case of mains voltage failure, the KX/EIB power supply and with it all connected bus devices are supplied with power from the storage battery. To increase the buffering time during a mains failure, a second storage battery can be connected to the system with a pre-assembled 2-wire connecting cable. Storage batteries and cable sets must be ordered separately as accessories. A potential-free change-over contact can be employed for fault signalling puposes in the event of mains failures, battery trouble, overvoltage / overloading and short-circuits. Up to 5 different LEDs on the front of the device inform the user about the different states of operation of the power supply. Layout: A 1 2 3 4 5 6 L1 E F G H 230V OK ϑ OK 12 V Code / 150 ma 650 ma 7 8 9 10 D Dimensions: Width: 144 mm (8 modules) Height: 90 mm Depth: 66 mm Betrieb B Überlast Reset 30V DC µ µ C I Controls and indicators: A: mains connection (L,, PE) B: connection for potential-free change-over contact (fault signalling contact) C: bus connection D: connecting terminals for storage battery and external temperature sensor (cf. wiring diagrams) E: LED "230 V OK" (green): lit up when mains voltage is OK. F: LED " OK" (green): lit up when storage battery is connected and OK. G: LED "Operation" (green): lit up when bus voltage is on and OK. Goes out in the event of bus voltage failure. H: LED "Overload" (red): Lights up in the event of overload (e.g. too many devices on the bus line) and of shortcircuit. Eliminate short-circuit / reduce load. Flashes when overvoltage at bus connection. Device switches off automatically (reset), Locate cause and rectify I: reset button and LED (red): LED lit up during reset state. 07/06 1079-00 Page 1/10

Technical data: Mains supply Voltage: Power rating: Power loss: Terminals: Bus output umber: Voltage: Rated current: Sustained short-circuit current: Connection: Max. line lengths: Mains buffering : Potential-free change-over contact Switched nominal voltage: Max. switched current: Min. switched current: Terminals: Battery and temperature sensor connection Type of storage battery: umber: Rated voltage: Battery capacity: Rated charging current: Temperature control: 195 V to 255 V AC, 45 / 65 Hz max. 50 VA max. 10 W screw terminals: 0.2 2.5 mm² stranded wire 0.2 4.0 mm² single-wire 1 line (integrated choke) 28 V to 31 V DC SELV max. 640 ma, withstanding continued short circuit max. 1.4 A KX/EIB bus connecting terminal 350 m between power supply and 'last-in-line' bus device 700 m between any two bus devices 1000 m overall bus line with storage battery: depending on total battery capacity: 1 x battery 12 V / 12 Ah: ca. 5.5 hours * 2 x battery 12 V / 12 Ah: ca. 11 hours * *: battery as new and full line loading. no battery connected: 200 ms 230 V AC or 12 / 24 V AC/DC 6 A AC or 4 A DC 100 ma (at U < 30 V AC/DC) screw terminals: 0.2 2.5 mm² stranded wire 0.2 4.0 mm² single-wire gelled lead-acid battery max. 2 of the same type in parallel 12 V DC preferably 12 Ah (also possible: 1 Ah, 7 Ah, 12 Ah, 17 Ah) 650 ma with total battery capacity > 5 Ah (terminals "Code / 650 ma -" and "12 V +") 150 ma with total battery capacity < 5 Ah (terminals "150 ma -" and "12 V +") temperature-controlled charging voltage regulation by means of external temperature sensor. sensor connection for total battery capacity > 5 Ah (terminals "150 ma -" and " ϑ") sensor connection for total battery capacity < 5 Ah (terminals "Code / 650 ma -" und " ϑ") Terminals: screw terminals: 0.2 2.5 mm² stranded wire 0.2 4.0 mm² single-wire Type of protection: IP 20 Mark of approval: KX / EIB Operating temperature range: -5 C... +45 C Storage / transport temperature: -25 C... +70 C (storage above +45 C reduces the lifetime) Type of fastening: snap-fastening on DI rail 35 mm as per DI E 50 022 (no data rail required). 1079-00 Page 2/10 Stand 07/06

Technical data "Gelled lead-acid storage battery 12 Ah" Rated voltage: 12 V DC Capacity: 12 Ah Dimensions: 94 x 151 x 98 (W x H x D [mm]) Weight: 4.2 kg Service life: 5 years Operating temperature range: -20 C... +50 C Storage / transport temperature: -20 C... +50 C Technical data "Basic cable set" Design: 4-wire connecting cable, pre-assembled, including temperature sensor and fuse Wire cross-section: 0.75 mm² Length of cable: 2 m Wire coding Battery connection: red: "+ 12 V DC battery" black: "- GD battery" Ferrules for connection to the uninterruptible power supply (USV). Faston receptacles and pole tabs for connection to battery. Connections to be made in acc. with the wiring diagram. Sensor connection: yellow: "- GD temperature sensor" white: "+ 12 V temperature sensor " Ferrules for connection to the uninterruptible power supply (USV). Connections to be made in acc. with the wiring diagram. Fuse Design: User replaceable fuse in in-line fuse holder with bayonnet lock. Type: 5 x 20 mm, time-delay type "T 6,3 H 250 V" Interrupting capacity 1,500 A Technical data "Extension cable set" Design: 2-wire connecting cable, pre-assembled, including fuse Wire cross-section: 0.75 mm² Length of cable: 2 m Wire coding Battery connection: red: "+ 12 V DC battery" black: "- GD battery " Ferrules for connection to the uninterruptible power supply (USV). Faston receptacles and pole tabs for connection to battery. Connections to be made in acc. with the wiring diagram. Fuse Design: User replaceable fuse in in-line fuse holder with bayonnet lock. Type: 5 x 20 mm, time-delay type "T 6,3 H 250 V" Interrupting capacity 1.500 A 07/06 1079-00 Page 3/10

Wiring diagram and assignment of terminals: Connection with storage batteries with a capacity of > 5 Ah (recommended) L PE L PE e.g. signal lamps 1 2 3 4 5 6 L1 µ µ change-over contact: no fault: contacts 4/5 closed, 5/6 open fault: contacts 4/5 open, 5/6 closed 230V OK OK Betrieb Überlast ϑ 12 V Code / 150 ma 650 ma 7 8 9 10 Reset 30V DC wh ye bk rd bk rd KX / EIB basic cable set (required) extension cable set (optional) bk rd bk rd ϑ storage battery additional storage battery 1079-00 Page 4/10 Stand 07/06

Wiring diagram and assignment of terminals (continued): Connection with storage batteries with a capacity of < 5 Ah L PE L PE e.g. signal lamps 1 2 3 4 5 6 L1 µ µ change-over contact: no fault: contacts 4/5 closed, 5/6 open fault: contacts 4/5 open, 5/6 closed 230V OK OK Betrieb Überlast ϑ 12 V Code / 150 ma 650 ma 7 8 9 10 Reset 30V DC wh bk ye rd KX / EIB basic cable set (required) bk rd ϑ storage battery 07/06 1079-00 Page 5/10

Hardware remarks: Storage batteries and cable sets: - The storage batteries used should preferably have a capacity of 12 Ah each. Storage batteries with the following capacities can, however, also be used: 1 Ah, 7 Ah, 17 Ah. Observe the wiring diagrams! - The total buffering time in case of mains failures depends on the total capacity of the storage batteries connected and on the loading of the KX/EIB line. For lines operating at full load, the following buffering times can be expected when completely charged and as good as new 12 V DC / 12 Ah storage batteries are used: 1 x battery ca. 5.5 hours 2 x batteries ca. 11 hours - The gelled lead-acid may only be connected to the uninterruptible power supply with the preassembled cable sets! The basic cable set is always necessary when a storage battery is connected to the power supply. If a second storage battery is to be connected to the supply, the extension cable set must be used. - ot more than 2 storage batteries of the same type in parallel may be connected to the uninterruptible power supply. - The maximum charging time of the storage batteries (12 V / 12 Ah) connected to the power supplies is 1 x battery ca. 28 hours 2 x batteries ca. 56 hours After a mains failure (batteries discharged), the storage batteries must be recharged. For this purpose, the mains voltage must remain on for a sufficiently long time as the batteries can otherwise not ensure the supply during the maximum buffering time. - Because of service life limitations, the storage batteries used should be replaced about every four years in order to ensure the supply during the maximum buffering time in the event of mains failures. - The uninterruptible power supply performs an automatic battery test every 15 minutes. If a battery fault is detected during the test, the potential change-over contact is switched to the fault position (contact 5/6 closed) and the LED " OK" goes out. The LED flashes in case of reverse polarity connection of the storage battery. After removal of the battery fault, the potential-free change-over contact switches back to normal position and the storage battery LED is illuminated green. The fault message is not stored. A battery test is also performed after a reset so that a test can be performed on demand by pressing the reset button. ote: In the worst case, it may take up to 15 minutes after occurrence of the fault until a battery fault is detected and signalled. Likewise, it may take up to 15 minutes after removal of the fault until the change-over contact goes back its normal position. - The gelled lead-acid batteries should preferably be installed inside suitable universal distributions. The storage batteries can thus also be protected against unauthorized access, if lockable doors are used. - When no battery is connected to the power supply, the " OK" LED is permanently off. Temperature sensor: - If a storage battery is connected to the uninterruptible power supply, it is absolutely necessary to connect the temperature sensor as well. Only the temperature sensor integrated in the basic cable set may be used. - The temperature sensor should be in good thermal contact with the battery connected to the cable set. The best solution is to fix the sensor with adhesive tape to the battery housing. 1079-00 Page 6/10 Stand 07/06

Fitting: - The uninterruptible power supply must be installed exclusively in distribution boxes or in control cabinets on a 35 mm DI rail. Sufficient ventilation is required to ensure that the admissible operating temperature range is not exceeded. - The uninterruptible power supply has no facility at the rear for making contact with a data rail. If data rails are to be supplied with power, additional data rail connectors must be used. Commissioning: - After correct connection of all lines, the mains voltage can be switched on. As a s short function test, all LEDs light up briefly three times. Thereafter, the green LED "230 V OK" is permanently on. If a storage battery is connected to the supply, the green LED " OK" lights up, too. The uninterruptible power supply is now ready for operation. If the storage battery is defective or if it has been connected with reverse polarity, the green LED " OK" flashes and the change-over contact goes to the fault position (contact 5/6 closed). In this case, the storage battery must be replaced altogether or properly reconnected with the correct polarity. ote: In the worst case, it may take up to 15 minutes after commissioning until a battery fault is detected and signalled. Likewise, it may take up to 15 minutes after removal of the fault cause until the green LED " OK" is on again permanently. - The uninterruptible power supply can also be put into operation without mains voltage in the buffering mode on condition that the storage battery is fully charged. After correct connection of the storage battery and the bus line, a battery test can be performed on demand by pressing the reset button. If no fault has been detected in the course of the test, the power supply switches over to battery operation and feeds the bus line. The power supply should not be run for too long on battery power without the mains being connected after commissioning to prevent discharging of the connected storage battery. Reset behaviour: - A press on the reset button generates a reset pulse on the connected KX/EIB line. In a reset, the bus line is disconnected from the power supply so that the connected bus devices are set back to their original state. To ensure a 'clean' reset procedure for all devices of the bus, the uninterruptible power supply maintains the reset condition for 20 seconds independent of how long the reset button is being pressed. During the reset, the red reset LED is on. Monitoring of the bus line: - Overload / short circuit: During an overload of the bus line, the red LED "Overload" is on. If the overload condition causes bus currents of more than 1.2 A (e.g. during a short circuit), the output voltage is automatically reduced and the green LED "Operation" goes out. A short-term overload will generally not cause any problems in the system. If the bus line is, however, overloaded or short-circuited for longer than 10 seconds, the potential-free change-over contact additionally switches to the fault position. The fault message is stored in the relay contact (cf. "Fault message" overleaf). - Overvoltage: If overvoltages occur on the bus line, the red LED "Overload" flashes. The potential-free changeover contact switches to the fault position. The uninterruptible power supply performs an automatic bus reset. During the reset, the red reset LED is on. The fault message is stored in the relay contact (cf. " Fault message" overleaf). - If overload and overvoltage occur at the same time, the overvoltage message has the higher priority, i.e. the red LED "Overload" flashes and the bus is automatically reset. The fault message is stored in the relay contact (cf. "Fault message" overleaf). 07/06 1079-00 Page 7/10

Fault message: - The uninterruptible power supply permanently monitors the connected bus line, the mains voltage and the storage battery voltage. In the event of faults, the green LED "Operation" goes out. The cause of the fault is indicated by means of the various LEDs on the front panel of the device and by the fault signalling contact in accordance with the following table: LED LED LED LED Fault signalling Reset LED State / fault cause "230 V OK" " OK" "Operation" "Overload" contact green green green off normal off normal operation green green green off normal red reset is active green green green flashes red fault red overvoltage, automatic reset is active. green green green flashes red fault off overvoltage fault stored, fault rectified off green green off fault off mains failure, battery operation green off green off fault off no battery, battery fault or battery empty off off off off fault off mains failure and no battery, battery fault or battery empty green green green off* red fault off green off green green off* red fault off off green off green off* red fault off green green green green off* flashes red fault off green off green green off* flashes red fault off off green off green off* flashes red fault off green green green green red fault off overload, output voltage OK off green green red fault off overload, output voltage OK, mains failure, battery operation green off green red fault off overload, output voltage OK, mains operation, no battery --- flashes green --- --- fault off battery defective or battery connected with reverse polarity *: green or off / ---: condition irrelevant. In the event of overload or overvoltage at the bus output, the fault message is stored. In this case, the potential-free change-over contact and the corresponding LED continue to remain in the fault state even if the cause of the fault message no longer exists and if the bus is again supplied with power. Although the system seems to work properly, the fault cause must be located and rectified by a service technician as the fault may be a recurrent fault. When the fault has been rectified, the stored alarm can be acknowledged and deleted by a single press on the reset button. The potentialfree contact switches back to normal position and the LED indicates the normal state of operation. Pressing the reset button a second time will reset the bus. If the fault has not been removed beforehand, a press on the reset button will result in a bus reset all right, but the fault remains stored and the potential-free change-over contact and the LED continue to remain in the fault state 1079-00 Page 8/10 Stand 07/06

- In the event of a mains failure, the bus line will be supplied from the connected storage battery, i.e the failure has no effect on the bus voltage. When the mains supply fails, the potential-free changeover contact switches to fault position and the LED "230 V OK" goes out. On return of the mains voltage, the potential-free change-over contact goes back to normal position and the LED is lit up green. The fault message is not stored. - If the fault messages are to be indicated, it is possible to connect LEDs or signal lamps to the fault signalling contact. A message can also be transmitted automatically to a service technician, if a suitable phone dialler is connected to the fault signalling contact. 07/06 1079-00 Page 9/10

Software description: ETS search path: system components / power supply / power supply 640mA DRA uninterruptible ETS-Symbol: Applications: Short description: ame: Date: Page: Data base o application! --- 09.03-10799110 1079-00 Page 10/10 Stand 07/06