Building Technologies



Similar documents
For UK only RXL39.1 and the applications package SP-03 are sold in the United Kingdom only.

Answers for infrastructure. HVAC control with Synco simple and energy-efficient

3873P01. Room controllers. For fan-coil applications FC-10, FC-11, FC12 with Konnex bus communications (S-mode and LTE mode)

Application Sheet Fan coil unit with staged fan, heating/cooling coil (2 pipe) on analog output

RDG/RDF room thermostats

RRV934. Multi-controller. Synco living

KNX for building and room automation simple and efficient

Semi flush-mount room thermostat with KNX communications For VAV heating and cooling systems

How To Build A Hotel Solution System

The ABB i-bus KNX Room Master Concept Your first step into the KNX world

Room thermostats wide variety and high energy efficiency

Desigo PX Automation system for HVAC and building services

ABB i-bus KNX Fan Coil Controller FC/S 1.1

Desigo building automation flexible and energy-efficient

Energy efficiency in building automation and control

Efficient building technology for retirement and nursing homes

VAV compact controller KNX / PL-Link

Desigo PX Automation system for HVAC and building services

Cooling with CHW (fan coil Heating with LTHW radiator Modulating control of heating and cooling valve Automatic or manual fan control

HVAC Processes. Lecture 7

UNIFIED FACILITIES GUIDE SPECIFICATIONS

Heating Controller. Building Technologies HVAC Products

Controls for fan coil units and cassettes

RVL470. Heating Controller. Building Technologies HVAC Products. Series B

Answers for infrastructure. HVAC building technology quality and energy effi ciency from strong partners

On/off room thermostats range. On/off V30 range. Master/slave PI V200 range. V3000 KNX networked PID range

3466 Building Energy Management Training Systems

VAV compact controller KNX / PL-Link

Product and Application Description

Communication in building automation

Flush-mounted room thermostats

T7560A,B,C Digital Wall Module

HVAC and Lighting Control Products for Open Building Automation Systems

More efficiency in office buildings with HVAC, lighting and security

Synco Central Communication Unit OZW771 Basic Documentation

ABB i-bus KNX. Room Solutions. ABB STOTZ-KONTAKT GmbH - 2CDC N0202, page 1

KNX. Siemens Building Technologies HVAC Products. Synco Konnex bus. For devices of the Synco 700 / RXB ranges

CRK24-B1 Heated/chilled ceiling system

ELABOTrainingsSysteme. Aus- und Weiterbildung GmbH. Home and Building Control KNX / EIB.

Thermostat with display

Heating / Ventilation / Air Conditioning Room Climate Control with ABB i-bus KNX

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

LMS The modular management system for condensing boilers. Control Products & Systems OEM. Answers for infrastructure.

Highly flexible the right KNX/DALI gateway for every requirement

ComfortPoint Open Building Management System. For consultants and specifiers. The Simply Smart way to optimize building control and performance

Communicating Thermostats. Add More Flexibility to Building Automation with New. Communicating Thermostats

SEZ220. Signal Converter. Synco 200. With preprogrammed standard applications Freely programmable Menu-driven operation. Use

User Manual. Air-conditioner Controller SB-DN-HVAC (MAC01.331)

Inwall Room Temperature Unit

Lighting and Fire Alarm Training System Add-On

TX OPEN RS232/485 module

More efficiency in hotels with HVAC, lighting and security

ADDENDUM TO THE CONTRACT. for the. Bartlett Regional Hospital Server Room Cooling System Replacement. Contract No. E12-149

More efficiency in schools with HVAC, lighting and security

Fundamentals of HVAC Control Systems

Building Technologies. Thermostats and room controllers. General Product range overview Thermostats

HVAC central apartment unit with consumption data acquisition

Designer. of control solutions NA O7.124A

PRODUCT PRODUCT CODE TECHNICAL INSTRUCTIONS PAGE

The THERMOSTAT THE EVOLUTION OF CAPABILITIES INTO A PLATFORM FOR ENERGY MANAGEMENT

Comfort and superior energy efficiency through intelligent home automation

siemens.gr/buildingtechnologies Answers for infrastructure.

SOLUTIONS FOR THE CONTROL OF THE WHOLE BUILDING

QFP910. Water detector. Building Technologies. CE1N2732en Synco living

Technical Manual. FAN COIL CONTROLLER COOLING or HEATING ANALOG or PWM Art A

LGAC-KNX PROGRAMMING MANUAL. Integrations V1.0 TECHNICAL SUPPORT. Tel (+34)

Synco 700 Central Control Unit RMB795 for use with RXB... room controllers

FIREDEX Conventional Fire Panels

MM8000 safety and security with smart danger management. A scalable and flexible management station for any requirement. Answers for infrastructure.

What s the Difference? 2 Pipe vs 4 Pipe Fan Coil

PXM20-E. Operator unit DESIGO PX

HERZ-Thermal Actuators

Operating instructions. RCD flat 4-fold, 6-fold

Company Profile. Building Automation / Management system: Capabilities: Supply,Testing and Commissioning

KNX Panasonic Air Conditioners


sip Sanyo Modbus Guide Technical Specification Pinouts, Cable Connections & Wiring Issue 2: February 2009 Synapsys Solutions Ltd, all rights reserved

TABLE 1: Wiring Terminals. Connect to... 1C 1H 2C 2H 1H1C 2H1C 2H2C 3H2C

Web-Server OZW V5.2

PRODUCT LIST Facility DDC Access WebXL DDC

OZW30. Central Unit SYNERGYR

T 3 Series VAV Diffusers Analog Diffuser Steel Square Panel Horizontal Pattern Model: T 3 SQ

HOTEL ROOM MANAGEMENT SYSTEM - specifications OVERVIEW

Energy Saving Tips. Adjust set point temperature up a few degrees... Window contact. Occupancy sensor. A Programmable Thermostat

HVAC central apartment unit with consumption data acquisition

B.IQ push button 3-5gang with room thermostat and display V2, flush-mounted x, x, x

C-Bus Application Messages & Behaviour Chapter 25 Air Conditioning

FX07 Field Controller

Workshop 7 PC Software - Tracker

OZW V2.0. Web server. Synco TM, Synco TM living

T5000 T000 LCD Digital Fan Coil Thermostat

Improved comfort and a green energy balance for your building

ABB i-bus KNX Switch Actuators SA/S Product Information

TAC I/NETTM MR-VAV-AX. Application Specific MicroRegulator TM

PC Software for VAV compact and modular controllers

A. The Commissioning Authority (CxA) has been contracted or will be contracted directly with the Owner for this project.

contents Leading the way in intelligent automation INELS Wireless? Why Click Accessories Complete control

ABB i-bus KNX Switch Actuators SA/S Product Information

Transcription:

Building Technologies RXB room automation system System overview

Contents Comfort and well-being in every room...5 Range overview...6 Coordinated room controllers...7 The room units: the key to individual comfort...8 Applications...10 Installation...11 Engineering and commissioning...12 Integration into building automation and control systems...15 RXB overview...18 3

4

Comfort and well-being in every room Most people in the industrial world spend 90 % of their time indoors. About one third of this time is spent at work. In this context it is clear that good indoor air quality, the right room temperature and draughtfree air renewal are vital prerequisites for motivation and a sense of well-being. The RXB room automation system ensures individual demand-based comfort for room users in public buildings, offices, schools, hotels and so on. The RXB controllers provide control and monitoring of the specific comfort conditions in rooms and other enclosed spaces. These functions are individually adapted to suit the requirements of each area of application (room or zone). This makes it possible to satisfy the demand for individual comfort and create a sense of well-being, while at the same time saving energy. One bus for HVAC, lighting and blinds The RXB controllers perform all the HVAC functions, while, for the control of lighting and blinds, various solutions are available on the market from different manufacturers. This third-party equipment is easy to combine with the RXB controllers, due to the clarity of the KNX specifications, the certification procedure and the use of ETS, the KNX Tool software. Stand-alone operation at field level, or integration into a building automation and control system The RXB controllers use the standard KNX protocol to communicate with each other and with other KNX devices. Devices at the field level can be integrated seamlessly into a building automation and control system. This is where all the higher-level control and coordination tasks, such as time scheduling, display, or energy optimization are performed. 10380z03 M Operation of HVAC equipment, lighting and blinds 5

Range overview RXB is an innovative range of room controllers and room units. Data communications are based on KNX technology. The RXB devices are certified by the Konnex Association. The RXB hardware The range comprises room controllers and room units for HVAC operation. The input and output configurations of the compact controllers, and the style of housing are fully optimized to suit their field of application. The HVAC functions are operated via standard room units. HVAC Electrical Lighting Blinds VAV Chilled ceilings Radiator-type heating KNX components for electrical applications RXB24.1 e.g. DELTA profil Fan coil units RXB21.1 RXB22.1 QAX... 10380z05en Controllers Operation RXB software Each RXB controller is loaded with software (referred to in this document as the "application") comprising a set of HVAC applications. The application actually required is enabled in the commissioning phase. The Building Automation section of Siemens Building Technologies holds a library of applications, which is continuously being expanded (see Overview, page 10). For the engineering and commissioning of a network of RXB controllers, use is made of ETS3, ACS or a "HandyTool". 6

Coordinated room controllers RXB21.1 and RXB22.1 compact room controllers for fan-coil units The input/output configuration and mounting options of these room controller s makes them ideal for fan coil applications. They can be installed in fan coil units, in control panels or on ducting. RXB24.1 compact room controller for chilled ceilings and radiators This controller contains chilled ceiling and radiator applications, and is designed for installation in ceiling voids or for underfloor or sill mounting. Inputs and outputs The functions of the inputs and outputs are determined by the particular application and its parameters. So, for example, the AC 24 V outputs can be configured either for thermic valve actuators or for 3-position actuators (depending on the application). Connections / Functions RXB 21.1 22.1 24.1 Power supply AC 230 AC 230 AC 230 KNX bus PPS2 interface for standard room unit (PPS2) Digital inputs 1) 2 2 2 Analog input for LG-Ni 1000 temperature sensor 1 1 1 AC 24 V outputs 2) 4 2 4 Volt-free relay outputs 3) 3 3 Relay for electric heating coil 1 1) For window switches, presence detectors and dew point sensors 2) For control of valve actuators (2-position, 3-position or both, depending on application) 3) For fan control 7

The room units: the key to individual comfort The room units of the RXB range cover the widely varying requirements of individual room occupants. When designing these stylish room units, the designers also paid special attention to ergonomic factors. The HVAC system, lighting and blinds can be operated in various ways: In the conventional way, with standard room units for HVAC and electric switches to control lighting and blinds Wireless room units for HVAC, which can be located anywhere in the room KNX switches and KNX actuators from third-party manufacturers Conventional HVAC room operation The standard QAX room units are available for HVAC applications. They are connected to the RXB controller via a special (PPS2) interface. In addition to the built-in room temperature sensor, the QAX3... und QAX9 room units incorporate a bus socket for the interface to the tool. Wireless HVAC room operation Wireless room units are ideal for use in renovation projects (no wiring required) in rooms with flexible partitioning and furnishing The wireless room units, types QAZ90.1 and QAX91.1 are used in conjunction with the RXZ90.1 receiver. The wireless EnOcean room units, types QAZ95.1 and QAX96.1 are used in conjunction with the RXZ97.1/KNX gateway. Electrical room operation A wide range of KNX devices is available on the market for the control of lighting and blinds. Room operation, HVAC Room operation, electrical KNX QAX... KNX buttons RXB21.1 RXB22.1 RXB24.1 KNX actuators (lamps and blind motors) KNX valve actuator 10380z08en 8

Functions of the room units Type Functionality of the room units QAX 30.1, 31.1 QAX 32.1 QAX 33.1 QAX 34.1 QAX 34.3 QAX 84.1/ PPS2 QAX 39.1 QAX 90.1, 91.1 QAX 95.1, 96.1 Built-in room temperature sensor Room temperature setpoint adjustment QAX 31.1 QAX 91.1 Selection of operating mode ( /Auto) 1) Selection of operating mode ( /Auto) 1) and fan speed LCD display for room temperature, operating mode and fan speed PPS2 interface to RXB room controller Wireless room units 2) Batteryless EnOcean technology 3) KNX Bus communications "HandyTool" (Parameter setting for KNX RXB controllers) QAX 96.1 1) Operating mode Auto: Comfort mode : PreComfort (Standby) or Economy, depending on control from the building automation and control system (see page 15) 2) For the QAX90.1 and QAX91.1 room units, the PPS2 interface is the RXZ90.1 receiver 3) For the QAX95.1 and QAX96.1 EnOcean room units, the KNX interface is the RXZ97.1 KNX gateway 9

Applications The scope of the RXB controllers is defined by the pre-programmed application modules. The following is an overview of the various applications and associated controllers. The controllers are shipped from the factory pre-programmed with a set of applications. The required application is then enabled with a tool (ETS3, ACS or the "HandyTool"). Due to the fact that the applications are largely pre-defined, engineering simply involves the definition of a small number of parameters, e.g.: 2-position or 3-position control of valves and actuators (depending on application) Temperature setpoints Manual or automatic fan control Fan coil systems (examples) 01577 M T Raum-Controller T Appl. Description Controller FNC02 Two-pipe system with change-over RXB21.1 / FC-10 FNC04 Four-pipe system RXB21.1 / FC-10 FNC08 Four-pipe system with room supply air cascade control RXB21.1 / FC-10 FNC20 Four-pipe system with control of a single damper RXB21.1 / FC-10 FNC10 Two-pipe system with change-over outside air damper RXB21.1 / FC-11 FNC12 4-pipe system with outside air damper RXB21.1 / FC-11 FNC18 Two-pipe system with change-over and radiator RXB21.1 / FC-11 FNC03 Two-pipe system with change-over and electric heater RXB22.1 / FC-12 FNC05 Four-pipe system with electric heater RXB22.1 / FC-12 Common functions Window contact, presence detector, four operating modes Manual fan control via room unit Automatic 3-speed fan control Options with two-pipe systems: Heating only, cooling only or changeover via KNX bus For a detailed description of the applications available, refer to the Applications library, CM110385 und CM110672. Chilled ceiling and radiator (example) 01578 Appl. Description Controller CLC01 Chilled ceiling RXB24.1 / CC-02 CLC02 Chilled ceiling and radiator RXB24.1 / CC-02 RAD01 Radiator RXB24.1 / CC-02 Raum-Controller T Common functions Window contact, presence detector, four operating modes Dew point sensor (CLC) Downdraft compensation (radiator) For a detailed description of the applications available, refer to the Applications library, CM110384 und CM110671. 10

Installation The RXB controllers are designed for various types of installation (mounted with screws or on DIN rail): In fan coil units In control panels In ceiling voids Under floors In sill or floor ducting. 01654 Various options for installation Terminal covers are required when mounting the controllers outside control panels or fan coil units (see page 18, Accessories). 70227 Example: RXB21.1 with terminal covers 11

Engineering and commissioning The RXB controllers can be operated either as stand-alone controllers or in conjunction with a building automation and control system. They are commissioned with one of the following tools, depending on their intended function: ETS3 Professional ACS The "HandyTool" (parameter-setting function of the QAX34.3 room unit) Engineering involves defining the number of RXB controllers needed on the basis of the room partitioning and zoning of the building, and specifying how these controllers are to be connected to each other and to third-party equipment. Commissioning involves downloading the data defined at the engineering stage (network structure, application, parameters and KNX connections etc.) into the RXB controllers. Project structure Depending on the size of the building, it may be advisable to create a project structure, e.g. by dividing the building into floors or wings. ETS3 supports this process with its own "Building View". A suitable bus structure can also be created with the ACS tool. The "HandyTool" does not support this process. Instead, a separate "addressing tool" based on an Excel spreadsheet is used. The tools and their functions Tool ETS3 ACS "HandyTool" Activity Available from Konnex Association, SBT SBT Brussel www.konnex.org Create project X X AT *) Select room controllers X X AT *) Select applications X X X Address room controllers X X X Configure/set parameters of X X X room controllers Create Konnex S-mode X -- -- connections (for DESIGO and third-party systems) Create Konnex LTE-mode X X X connections based on zones (for Synco) Project documentation X X AT *) *) AT = Addressing Tool Utility based on Excel Supplied by SBT free of charge 12

Parameter setting For details, please refer to documents CM110384 and CM110385. Communications links For the integration in building automation and control systems, communications links are created by use of group addresses (ETS3). 13

Addressing Every device must have its own physical address. Addresses can be assigned with one of the three tools. Options for connecting the tools KNX Building autometion interface 1 *) 2 *) 3 *) PPS2 4 PPS2 5 10380z09en 1. ETS3 or ACS connected to standard room unit *) 2. ETS3 or ACS connected to RXB controller *) 3. ETS3 or ACS connected to KNX bus *) 4. "HandyTool" connected to standard room unit 5. "HandyTool" connected to RXB controller *) via OCI700 USB KNX port 14

Integration into building automation and control systems BACnet USB KNX / EIB Backbone PX KNX 1 PX KNX 2 OCI700 KNX Area 2 Area coupler 2.0.0 KNX 10380z10en Line coupler 2.3.0 Line coupler 2.7.0 RMH... RMU... RMB795 Bus supply Room controllers Bus supply Room controllers Bus supply Room controllers Third-party devices Third-party devices Third-party devices KNX Line 3 KNX Line 7 Standalone operation at field level The room automation system can be operated as a standalone system. All the necessary functions can be implemented by means of the KNX communications between RXB controllers, and between these and any KNX-compatible third-party equipment. Integration into the automation level There are different possibilities for integrating RXB controllers into a building automation and control system: The PX-KNX integration station, which converts the KNX communications objects into BACnet data points. Typically up to 45 RXB controllers can be integrated per PX KNX interface controller. The OCI700 interface, which converts KNX information into USB format. 15

Integration into the management level Depending on the degree of complexity required, a management station incorporates the following program modules for the user: Graphics-based operation of the site (plant graphics) Time schedules for a wide range of switching routines Display and modification of data point values Routing of alarm messages etc. Example of a graphic user interface. 16

Central and local control of operating mode The diagram below shows an example of how the central time schedules (Building use and Room occupancy) interact with the local /Auto control on the room unit (operating as an occupancy function in this case). It is also possible to use a presence detector for local control. Building use 10380z11en Room operating mode Room occupancy Comfort 1) Pre-Comfort (Stand-by) 2) Economy 3) Local /Auto Auto Auto Auto Auto 4) t Central Room occupancy 07.00 17.00 Central Building use 05.00 22.00 Example of the routines over a typical day: 1) Comfort In this mode, the room temperature is within the comfort range. 2) PreComfort (Standby) The heating or cooling output is slightly reduced (during the temporary absence of the room occupant) 3) Economy The heating or cooling output is reduced significantly. 4) Outside the times defined by the Building use schedule, local operation has no influence on the operating mode 17

RXB overview RXB room controllers Document RXB21.1, Room controller for fan-coil units CM2N3873 RXB22.1 RXB24.1 Room controllers for chilled ceilings and radiators CM2N3874 RXB room units QAX30.1 Room unit with temperature sensor CA2N1741 QAX31.1 Room unit with temperature sensor and setpoint adjuster CA2N1741 QAX32.1 Room unit with temperature sensor, setpoint adjuster and /Auto switch CA2N1641 QAX33.1 Room unit with temperature sensor, setpoint adjustment and /Auto/Fan switch CA2N1642 QAX34.1 Room unit with temperature sensor, setpoint adjustment, /Auto/Fan switch and CA2N1645 LCD QAX34.3 Room unit with temperature sensor, bias switches for setpoint adjustment/ CA2N1640 /Auto / fan speed and LCD display, with "HandyTool" function QAX39.1 Universal setpoint adjuster CA2N1646 QAX84.1 Flush-mounting room unit with temperature sensor, setpoint adjuster, /Auto CA2N1649 button / fan speed and LCD indication QAX90.1 Wireless room unit with temperature sensor CA2N1643 QAX91.1 Wireless room unit with temperature sensor and setpoint adjuster CA2N1643 RXZ90.1 Receiver with PPS2 interface, for wireless room units CA2N1644 QAX95.1 EnOcean room unit with temperature sensor CM2N1660 QAX96.1 EnOcean room unit with temperature sensor and setpoint adjuster CM2N1660 RXZ97.1/KNX EnOcean gateway with KNX interface CM2N1662 RXB commissioning aids RXT20.1 Service terminal CA2N3851 Integration interfaces PX KNX Comprises PXC00-U and PXA30-K11 CA1N9221 CM1N9280 OCI700 USB-KNX interface CE1N5655 Accessories RXZ20.1 Terminal covers for RXB21.1 and RXB22.1 and RXB24.1 CM2N3873 CM2N3874 UA1T Power amplifier for thermic valve actuators CA2N3591 ACX95.320/ALG Bus power supply 320 ma CE2Q3663 Other RXB documentation RXB (KNX) technical manual RXB integration S-Mode RXB / RXL integration Individual addressing Third-party integration Synco integration Working with ETS System description DESIGO System description Synco CM110389 CM1Y9775 CM1Y9776 CM1Y9777 CM1Y9778 CM1Y9779 CM110660 CE1S3110 18

19

Siemens Switzerland Ltd Building Technologies Division International Headquarters Gubelstrasse 22 CH-6301 Zug Tel. +41 41-724 24 24 Fax +41 41-724 35 22 www.buildingtechnologies.siemens.com Building Technologies Subject to technical change CM110380en_03 28 Feb 2009