Reversing starter circuit for single phase induction motors Updated 1 st September 2008



Similar documents
conventional system operation

SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original

Chapter 5. Components, Symbols, and Circuitry of Air-Conditioning Wiring Diagrams

Unit 24: Applications of Pneumatics and Hydraulics

SECTION 4 ELECTRIC MOTORS UNIT 17: TYPES OF ELECTRIC MOTORS

3BASIC RELAY INSTRUCTIONS

..OR How To Protect your 3-Phase Equipment Investment with 3-Phase Monitors from Time Mark...

REB 1 REB 3 REB 5 REB 6 REB 8 REB 10 REB 12 REB 16

GROUND DETECTION CIRCUITS FOR STATIONARY APPLICATIONS (IN PLAIN DOWN TO EARTH LANGUAGE)

3.0 CHARACTERISTICS. AR Auxiliary Relay High Speed, High Threshold C

3PH2 or 3PHE 3 Phase Control Board

Motor Fundamentals. DC Motor

CHECK LIST OF SITE INSPECTION ON LV ELECTRICAL INSTALLATION (Basic Information to be filled by Consultant)

ELECTRICAL CIRCUITS. Electrical Circuits

AND8008/D. Solid State Control Solutions for Three Phase 1 HP Motor APPLICATION NOTE

!Operation:!1. Connect an external power source to J1 (+ and - IN terminals). The

GLOLAB Two Wire Stepper Motor Positioner

DIRECT CURRENT GENERATORS

Standex-Meder Electronics. Custom Engineered Solutions for Tomorrow

Rotary Phase Converters

Programming A PLC. Standard Instructions

PUSH BUTTON START INSTALLATION MANUAL

Equipment: Power Supply, DAI, Synchronous motor (8241), Electrodynamometer (8960), Tachometer, Timing belt.

LG Air Conditioning Multi F(DX) Fault Codes Sheet. Multi Split Units

ATS - Automatic Changeover

Type: DILM115(RAC240) Article No.: Sales text Contactor,55kW/400V,AC operated. Ordering information

DC Motor control Reversing

Wires & Connections Component Circuit Symbol Function of Component. Power Supplies Component Circuit Symbol Function of Component

73 Chevy C10 Ammeter to Volt Gauge Conversion Mark and Michael Olson 2013 Rev 1.0

Electronic overload relay EF65, EF96 and EF146

Motors and Generators

Comparison of NEMA and IEC schematic diagrams

Oil and Coolant Circulating Heating System. Model - OCSM

Whale 3. User Manual and Installation Guide. DC Servo drive. Contents. 1. Safety, policy and warranty Safety notes Policy Warranty.

Induction Motor Theory

Electronic overload relay EF19 and EF45

Objectives. Capacitors 262 CHAPTER 5 ENERGY

INSTALLATION & SERVICE MANUAL. Display Panel

, User s Manual

AC motor control circuits

Equipment: Power Supply, DAI, Wound rotor induction motor (8231), Electrodynamometer (8960), timing belt.

SYSTEM 4C. C R H Electronics Design

Sentron Series Circuit Breakers

Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000

Electrical Symbols and Line Diagrams

Circuit Breakers. NRC Series. NRC Series

SYSTEM 45. C R H Electronics Design

Measuring Electric Phenomena: the Ammeter and Voltmeter

JANUS INTERNATIONAL CORPORATION INSTALLATION INSTRUCTIONS Pantheon Mini Operator

Section B: Electricity

Product Description Primary Resistance Starting Electric Fire Pump Controllers FTA1500

2. A conductor of length 2m moves at 4m/s at 30 to a uniform magnetic field of 0.1T. Which one of the following gives the e.m.f. generated?

Bypass transfer switch mechanisms

ETZGAR CONVEYOR COMPANY Controls Section v12.05

Solid Core and Split Core Adjustable Current Status Switches CSS-O, CSS-C; CSP-O, CSP-C

Impedance Matching and Matching Networks. Valentin Todorow, December, 2009

Windshield Wiper Motors

EET272 Worksheet Week 8

Torque control MSF Softstarter

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller

Chapter 22: Electric motors and electromagnetic induction

ABB ! CAUTION. Type COQ Negative Sequence Generator Relay. (50/60 Hertz) J. Instruction Leaflet

SYNCHRONOUS MACHINE TESTING WITH MOTOR CIRCUIT ANALYSIS INSTRUMENTATION

A.Y. McDonald Mfg. Co. Troubleshooting Submersible and Jet Pumps

MODEL 5010 DUAL CHANNEL SMOKE/FIRE DETECTION MODULE

STUDY GUIDE: ELECTRICITY AND MAGNETISM

Single Channel Loop Detector

Modular I/O System Analog and Digital Interface Modules

INTRODUCTION. The data provided is for The Standard Products and any variation will be dealt with at the end of this manual.

60 Series - General purpose relays 6-10 A. Features

Specifying a Variable Frequency Drive s

Q1-750 Q Q Q Q2-200 Q4-90 Q4-120 HIGH PERFORMANCE AMPLIFIER

FUEL-16, Troubleshooting Fuel Supply Problems

Short Range Wireless Switch System Handheld 8 Installation and Operations Guide

TECHNICAL SUPPORT MANUAL 3 Phase Air Conditioner Component R2A3**GHR

LG Air Conditioning - Universal Split Fault Codes Sheet. Universal Split Systems

Industrial Automation Commonly-Used Terms

Product Guide. Low voltage grounding system. Answers for industry.

Permanent Magnet Motor Kit, Magnetic Reed Type. (SKY-ReedMotorKit) Instructions

Induced voltages and Inductance Faraday s Law

NATIONAL CERTIFICATE (VOCATIONAL)

Renewable Energy Monitor User Manual And Software Reference Guide. (979)

Generator Stator Protection, under/over voltage, under /over frequency and unbalanced loading. Ramandeep Kaur Aujla S.NO

Essential Electrical Concepts

US Breaker Brand 3 Pole AC Contactors (Square D Telemecanique LC1 Replacements)

Parts list and Notes for making a 10 hp 240V single phase to 240V 3-phase converter.

Section 9.5 Electric Motors

FLORIDA STATE COLLEGE AT JACKSONVILLE NON-COLLEGE CREDIT COURSE OUTLINE

Product Guide AC Voltage Control Devices. Guide Guide. Popular Variable Transformers and AC Power Supplies.

Michelin North America

INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks

An Easy to Build and Operate Induction Generator

Inverter / Charger Installation General Operations and AC and DC Connections

Circuit Breakers. Next Generation of Protection Capabilities

Line Reactors and AC Drives

Medium Voltage (MV) & High Voltage (HV) Training Module 6. Date of the presentation

TS510 & TS500. Installation & User Guide. Compatible Equipment

OPERATION MANUAL VALVE CHECKER G

Principles of Adjustable Frequency Drives

Understanding Power Factor and How it Affects Your Electric Bill. Presented by Scott Peele PE

Transcription:

Reversing starter circuit for single phase induction motors Updated st September 008 Most single phase electric motors fitted to machine tools, compressors etc. are squirrel cage induction type which can be reversed by re-arranging connections to their terminals. Drum or rotary switches are often used to select direction of rotation of single phase motors but they are expensive, do not have a No Volt Release (NVR), nor overload protection and are not ideal for switching motors on or off. Basic circuit - figure There are Stop, Forward and Reverse buttons, two low current double pole double throw relays for the control circuit (thin wire lines) and the power circuit (thick wire lines) which uses a double pole single throw relay (R) and a double pole double throw relay (RDIR). The circuit is drawn with the control circuit isolated from the power section; that enables the use of relays with coils that operate at a different voltage from the mains. Where that is done, the relay coils must all operate at the same voltage and power for them is applied to A and B. Where the relay coils operate at mains voltage simply link L to A and N to B. When R is energised and RDIR is unenergised the motor runs in one direction but, if RDIR is energised, the motor runs in the reverse direction. The contacts to 7 of RF and RR act as NVR (No volt release) latches for the Fwd & Rev buttons and to 7 of RR energise the coil of RDIR when the Rev button is pressed or latched. Contacts to remove power to the Rev button when the motor is running forward and vice

versa; this ensures that pressing either, or both, direction buttons, when the motor is running, has no effect. Contacts to of either energise the coil of R when a direction button is pressed or latched. A remote stop button may be wired in place of LK. Note that there is no protection for motor overload other than any fuse or circuit breaker in the mains supply. Enhanced circuit - figure R of fig. is replaced by a conventional motor contactor (CO) and overload device (OL). The N/C contact of OL is in series with the stop circuit so the motor stops when an overload occurs. Practical considerations Pin numbering The pin numbers in the figures are arbitrary and only drawn to assist in describing or tracing the function of the circuit. Motor types There are several varieties of single phase squirrel cage motors which are well described at http://www.leeson.com/products/techref/sphase.htm 0 Oct 00. The above link is no longer valid I have emailed Leeson to see if the page is available elsewhere Motor connections Most motors have a terminal box bolted to, or comprising part of, the main body. Wires from the windings or rotary switch (within the motor body) pass straight into the terminal box. Apart from split-phase motors, one or two capacitors are normally fixed to the outside of the body and their leads pass into the box via individual gland or grommet holes. A further gland or grommet hole is provided for the cable supplying power. You need to determine which terminals are connected to the main and start/aux windings of the motor. Quite often there will be a label inside the terminal box showing which are which.

They are also, sometimes, labelled but there is no standardised marking. Some quite common ones are: Start terminals Z and T Run terminals A and AZ or Start terminals Z and Z Run terminals U and U or Start terminals Z and Z Run terminals A and A Where no such identification is available, the terminals can be identified by measuring the resistance between pairs of terminals. The resistance of the start/aux winding is always greater than that of the main winding by, typically, a factor of or. As an example, a 00W motor s start winding is ohms and the main is. Values will be a lot lower for larger motors. Note that the reading between terminals & of the Cap start/cap run circuit will be 0 ohms so should not be confused with the low resistance of the main winding. Typical connection circuits for different motor types are given below but they may not apply to all configurations. For example, the connection between the rotary switch and start/aux switch may be done at an additional terminal instead of inside the motor body. IF IN DOUBT, ASK SOMEONE WHO KNOWS ABOUT S C C C AUX. CAP /CAP CAP /INDUCTION C AUX. PERMANENT SPLIT CAPACITOR SPLIT-PHASE Relays and contactor If the basic circuit is used then the contact rating (for inductive loads) of Rmain should be at least that of the starting current of the motor which may be several hundred percent of the full load current. Some figures are given in the link listed in Motor types. In practice you can probably get away with a lower rating for hobby use but it should be rated for at least the full load current.

A contactor intended for motor control only needs to be rated for the full load current of the motor as it is designed to handle larger make and break currents. The overload should be set to the full load current. Note that overloads are normally mounted directly to the contactor so do not try to mix devices from different manufacturers or ranges without checking that they mount satisfactorily. The contactor/overload is wired so that the line current passes through poles. This is because they are normally made in three pole version for three phase installations and some may trip if there is an imbalance of current through the overload poles as would occur if one phase of a three phase motor failed or became disconnected. For both the basic and enhanced circuits the contact rating of Rdir need only be the motor full load current of the motor and could, quite possibly, be less. For most configurations a contact rating of 00mA for RF & RR is adequate but if the coil voltage of relays is low or the enhanced circuit is used then a higher rating may be required check the current required to energise the coils. Bob Kellock bob@chainganger.co.uk August 008 Update st September 008 This is a variation which uses a way Fwd-Off-Rev switch and Start button instead of three buttons. L A FUSE A STOP LK R RDIR 8 7 RL B N SW FWD-OFF-REV SW POLE ON-OFF-ON TOGGLE OR SLIDE SWITCH OR POLE WAY ROTARY TYPICAL TOGGLE SWITCH = RS 90-070 TYPICAL ROTARY SWITCH = RS -88 The motor is turned off automatically when you switch from forward to reverse unless you move the switch extremely rapidly (in which case clouds of smoke may appear if it s a Cap start/cap run or Permanent split capacitor motor*). R can be replaced by a contactor and overload as for the three button version. * This would equally occur with the original circuit if you press Stop followed by the opposite direction button while the motor is still turning. There s nothing you can really do about it

without resorting to a device that would inhibit starting unless the motor is stationary; that would be complex. Yet another The following circuit is the simplest of all and acts just like an electro-mechanical reversing switch e.g. a Dewhurst. There is no No Volt Release so if you incorporate a contactor and overload (with the overload contact between the fuse and SW) the overload MUST BE manual reset. L A FUSE A SW R RDIR 8 7 REV-OFF-FWD B N SW POLE ON-OFF-ON TOGGLE OR SLIDE SWITCH OR POLE WAY ROTARY TYPICAL TOGGLE SWITCH = RS 90-070 TYPICAL ROTARY SWITCH = RS -88