FRET Basics and Applications an EAMNET teaching module



Similar documents
Molecular Spectroscopy

Leica TCS SP5 Confocal Laser Scanning Microscope User Guide 1. BASIC IMAGE ACQUISITION

CyAn : 11 Parameter Desktop Flow Cytometer

Fluorescent dyes for use with the

Applications of confocal fluorescence microscopy in biological sciences

ZEISS Microscopy Course Catalog

Distinguishing GFP from Cellular Autofluorescence

Confocal Fluorescence Microscopy

Zeiss 780 Training Notes

Technical Note. Roche Applied Science. No. LC 19/2004. Color Compensation

Two-photon FCS Tutorial. Berland Lab Department of Physics Emory University

Chapter 12 Filters for FISH Imaging

COMPENSATION MIT Flow Cytometry Core Facility

Multicolor Flow Cytometry: Setup and Optimization on the BD Accuri C6 Flow Cytometer

QDot Nanocrystals Insights

Single Defect Center Scanning Near-Field Optical Microscopy on Graphene

Tandem Scanner. Leica TCS SP5 II: The Broadband Confocal High Speed and High Resolution All in One

Technical Note. Roche Applied Science. No. LC 18/2004. Assay Formats for Use in Real-Time PCR

AxioCam MR The All-round Camera for Biology, Medicine and Materials Analysis Digital Documentation in Microscopy

Zecotek S Light Projection Network Marketing

Optimizing Performance of the Transcreener ADP Assay for the BioTek Synergy 2 and 4 Multi-Mode Microplate Readers

Three Rules for Compensation Controls

Super Resolution Optical Microscopy. Bo Huang

Goat Anti Mouse IgG Antibodies

Recording the Instrument Response Function of a Multiphoton FLIM System

Goat Anti Rabbit IgG Antibodies

Exciton Diffusion. Exciton Diffusion

Technical Bulletin. An Introduction to Compensation for Multicolor Assays on Digital Flow Cytometers

Katharina Lückerath (AG Dr. Martin Zörnig) adapted from Dr. Jörg Hildmann BD Biosciences,Customer Service

Fluorescence Microscopy for an NMR- Biosensor Project

FluoProbes dyes. FluoProbes dyes directly conjugated to secondary antibodies

Lecture 4 Scanning Probe Microscopy (SPM)

FlowSight. Flow cytometry with vision

Z-Stacking and Z-Projection using a Scaffold-based 3D Cell Culture Model

By: Christine Labno, Ph.D. Assistant Director, AB129 site Office: AB129 (Abbott Hall) Phone: x

Lecture 1: Basic Concepts on Absorption and Fluorescence

Advances in scmos Camera Technology Benefit Bio Research

Products - Microarray Scanners - SpotLight Two-Color Microarray Fluorescence Scanners New! SpotLight 2 now available!

Chapter 10 Immunofluorescence

MiSeq: Imaging and Base Calling

Instrument Characterization and Performance Tracking for Digital Flow Cytometers

TCSPC for FLIM and FRET in Microscopy

CAMÉRAS EMCCD POUR LA QUANTIFICATION DE FLUORESCENCE IN VIVO

FLUORESCENT PROTEINS - XFPs

Compensation in Flow Cytometry

Confocal Microscopy and Atomic Force Microscopy (AFM) A very brief primer...

AxioCam HR The Camera that Challenges your Microscope

Alignment and Preprocessing for Data Analysis

Co Extra (GM and non GM supply chains: Their CO EXistence and TRAceability) Outcomes of Co Extra

Fluorescence and Fluorescence Applications

AxioCam MRm Pure Sensitivity

Introduction to flow cytometry

Webex-based remote instrument control guide

SmartFlare RNA Detection Probes: Principles, protocols and troubleshooting

Lecture 20: Scanning Confocal Microscopy (SCM) Rationale for SCM. Principles and major components of SCM. Advantages and major applications of SCM.

Advantages of the Alexa Fluor 488 secondary antibody conjugates

Introduction to Confocal Laser Scanning Microscopy (LEICA)

CyFlow Space Your flexible flow cytometer

N-STORM. Super-resolution Microscope. Operation Manual

Flow cytometry basics fluidics, optics, electronics...

Principles of Flowcytometry

Microscopy: Principles and Advances

Time out states and transitions

NyONE - Cell imaging in a bird s eye view 4. NyONE...resolution matters! 8. Features & benefits 10. Fluorescence excitation channels 12

DNA Detection. Chapter 13

Measuring the Point Spread Function of a Fluorescence Microscope

Cell Viability Assays: Microtitration (MTT) Viability Test Live/Dead Fluorescence Assay. Proliferation Assay: Anti-PCNA Staining

Near-field scanning optical microscopy (SNOM)

Application Note. Selecting Reagents for Multicolor Flow Cytometry. Holden Maecker and Joe Trotter BD Biosciences, San Jose

University of Cyprus Biomedical Imaging and Applied Optics Laboratory Light-Tissue Interaction

5.33 Lecture Notes: Introduction to Spectroscopy

Colorful choices for your bright ideas

Reversible Dimerization of Aequorea victoria Fluorescent Proteins Increases the Dynamic Range of FRET-Based Indicators

Wide range of applications from Real time imaging of low light fluorescence to Ultra low light detection

TECHNICAL BULLETIN. FluoroTag FITC Conjugation Kit. Product Number FITC1 Storage Temperature 2 8 C


Nano Optics: Overview of Research Activities. Sergey I. Bozhevolnyi SENSE, University of Southern Denmark, Odense, DENMARK

Raman Spectroscopy Basics

2012 HORIBA Scientific. All rights reserved HORIBA Scientific. All rights reserved.

Realization of a UV fisheye hyperspectral camera

PHYSICAL METHODS, INSTRUMENTS AND MEASUREMENTS Vol. IV Femtosecond Measurements Combined With Near-Field Optical Microscopy - Artyom A.

Labeling and Detection. The best and brightest Alexa Fluor dyes

WESTERN BLOT DETECTION KIT Buffers and detection reagents for up to ten 10 x 10 cm 2 blots. Fluorescent detection via: Goat anti-mouse SureLight P3

IMMUNOFLUORESCENCE MODULE 62.1 INTRODUCTION. Notes

Collagen I Self-Assembly: Revealing the Developing Structures that Generate Turbidity. Supporting Material

A Brief History of the Microscope and its Significance in the Advancement of Biology and Medicine

Hidex Sense. Hidex Triathler Multi-technology Microplate Reader. Hidex AMG. Consumables. Hidex 300 SL.

Fundamentals of modern UV-visible spectroscopy. Presentation Materials

Leica TCS SP5 The Multi-User Confocal Microscope

Transcription:

FRET Basics and Applications an EAMNET teaching module Timo Zimmermann + Stefan Terjung Advanced Light Microscopy Facility European Molecular Biology Laboratory, Heidelberg http://www.embl.de/almf/ http://www.embl.de/eamnet/

Overview 1) Fluorescence Resonance Energy Transfer Basics 2) Confocal FRET detection techniques 3) FRET and fluorescent proteins 4) A new GFP FRET pair with increased efficiency

The resolving power of light microscopes is limited to distances of hundreds of nanometers (<organelles). Fluorescence Resonance Energy Transfer (FRET) allows the detection of molecule-molecule interactions in the nanometer range with light microscopy. FRET is sometimes also called Förster Resonance Energy Transfer, as Förster was the first who published quantitative theory of molecular resonance energy transfer (Förster 1946, Förster 1948). Organelles Cells Worm Housefly Human FRET 1 Å 10-10 m 1 nm 10-9 m 1 µm 10-6 m 1 mm 10-3 m 1 cm 10-2 m 1 m light microscopy resolution limit

Fluorescence Resonance Energy transfer (FRET) FRET is a non-radiative transfer of energy from an excited donor molecule to a suitable acceptor molecule in close proximity. Fluorescence Resonance Energy Transfer Wouters et al. (2001), TICB 11/5 In the case of FRET, excitation of the donor fluorophore results not only in donor emission, but partially also in emission characteristic for the acceptor fluorophore.

Dependence on distance and spectral overlap The efficiency of energy transfer strongly depends on the distance between the donor and acceptor molecules and on overlap of the donor molecule emission and acceptor molecule excitation spectra high specificity. FRET efficiency is depends on molecule distance The FRET efficiency depends on the distance between the two interacting molecules. At the distance of the Förster radius R 0 between the molecules, the FRET efficiency is 50%. The typical R 0 is around 3 nm.

Donor/Acceptor Pairs Examples for common FRET Donor/Acceptor pairs: Donor (Em.) Acceptor (Exc.) FITC (520 nm) Cy3 (566 nm) EGFP(508 nm) CFP (477 nm) EGFP (508 nm) TRITC (550 nm) Cy5 (649 nm) Cy3 (554 nm) YFP (514 nm) YFP (514 nm)

FRET detection methods A variety of FRET detection methods exist for light microscopy Acceptor photobleaching Donor photobleaching Ratio imaging Sensitized emission Fluorescence lifetime measurements

FRET detection methods The detection methods have different properties and are suited to different samples Detection of changes: Acceptor photobleaching Donor photobleaching Information self-contained: Ratio imaging Sensitized emission => fixed samples => in vivo Fluorescence lifetime measurements

Acceptor Photobleaching Experimental steps of acceptor photobleaching measurements In acceptor photobleaching, the acceptor molecule of the FRET pair is bleached, resulting in a brightening (unquenching) of the donor fluorescence. Prebleach Image Zoom 4x Bleaching Original Zoom Postbleach Image Median Filtering Subtraction: Postbleach Prebleach Division: Subtraction/ Postbleach GFP 488 488 488 GFP 543 Cy3 543 543 Cy3 An apparent FRET efficiency (product of the efficiency of the FRET pair and the amount of interacting donor) can be calculated Acquisition Processing

Acceptor photobleaching Shift Correction by Cross-Correlation helps avoiding edge artifacts in the comparison of pre- and postbleach images. Edge artifacts Without correction With correction

Donor photobleaching The bleaching rate of the donor fluorophore is affected by FRET. Measuring the bleaching of the donor in the presence/absence of acceptor is a possibility to detect FRET. Fluorescence lifetime FRET decreases donor fluorescence lifetime => decreased likeliness of bleaching => decreased bleaching rate An apparent FRET efficiency (product of the efficiency of the FRET pair and the amount of interacting donor) can be calculated. However: Quantitation is problematic due to direct and indirect bleaching of acceptor

Overview 1) Fluorescence Resonance Energy Transfer Basics 2) Confocal FRET detection techniques 3) FRET and fluorescent proteins 4) A new GFP FRET pair with increased efficiency

FRET and Fluorescent Proteins (FPs) Protein-Protein Interactions: - FRET between an FP and a dye -FRET betweenfps Cameleons: In vivo measurements of physiological changes (ratio imaging)

Measurement of Protein Phosphorylation by FRET Application example: An acceptor-labelled antibody against a phosphorylated residue can be used to detect the phosphorylation status of a GFP-fusion protein by FRET Cy3 anti-p-thyr d>ro GFP-Protein Not Phosphorylated P d<ro GFP-Protein Phosphorylated Verveer, et al. 2000

Acceptor photobleaching Receptor phosphorylation after EGF-Stimulation 0 min 2 min 5 min ErbB1-GFP/Cy3 FRET (receptor phosphorylation), Verveer, et al. 2000

CFP/YFP The combination of cyan and yellow fluorescent protein is the most commonly used fluorescent protein FRET pair

Fluorescence Resonance Energy Transfer Cameleon Tandem constructs CFP YFP Pollock and Heim TiCB 1999, Miyawaki et al. Nature 1997

In vivo CFP/YFP cameleon measurements Measurements caried out on the Leica SP2 AOBS at 405 nm excitation: 2 µm Ionomycin + 20mM CaCl 2 Histamine EGTA

Cross-talk and cross-excitation of two fluorophores is an intrinsic problem of multichannel measurements and is also present in FRET measurements Channel 1: 460-500 nm Channel 2: 460-500 nm RGB Overlay CFP only YFP only CFP+ YFP

Sensitized emission detection D D A D A D A A Ratiometric imaging can only be done in samples with a fixed stochiometry of donor and acceptor (e.g. Cameleons) A A A A D D D A A D D A In samples with variable stochiometries, the detected acceptor fluorescence has to be corrected for emission cross-talk and for cross-excitation A A

Sensitized emission detection Predetermined factors with pure samples of donor and acceptor: Donor cross-talk : R D Acceptor cross-excitation: R E Required images: Donor channel Donor excitation F D Acceptor channel Donor excitation F DA Acceptor channel Acceptor excitation F A F DA corr/f A => Donor cross-talk correction Acceptor cross-excitation correction corr

Overview 1) Fluorescence Resonance Energy Transfer Basics 2) Confocal FRET detection techniques 3) FRET and fluorescent proteins 4) A new GFP FRET pair with increased efficiency

CFP/YFP Cyan and yellow fluorescent protein is the most commonly used fluorescent protein FRET pair

Requirements for a good FRET pair -Maximal overlap of donor emission and acceptor excitation -Minimal direct excitation of the acceptor at the excitation maximum of the donor

Spectral overlap of FRET Pairs The spectral overlap of donor emission and acceptor excitation is only partial for CFP/YFP and much better for GFP/YFP pairs

Requirements for a good FRET pair -Maximal overlap of donor emission and acceptor excitation -Minimal direct excitation of the acceptor at the excitation maximum of the donor

Different Cross-Excitation of FRET Pairs Using a suitable laser excitation for CFP, YFP is directly excited significantly (=> high background signal) GFP2 is excitable around 400 nm, where YFP is almost not excitable (=> low background signal) 458 405

Comparison of CFP/YFP and GFP2/YFP FRET pairs CFP YFP glycine linker exc. 405/458 nm GFP2 YFP glycine linker exc. 405 nm

Acceptor photobleaching Comparison of CFP and GFP2 in the same construct Before After CFP-YFP: FRET efficiency 20% GFP2-YFP: FRET efficiency 30% => 50% increase

Improved FRET Efficiency significantly improves Detection Whereas the differences between FRET pairs are not significant at high transfer efficiencies, a more efficient FRET pair significantly improves the detectable FRET interaction in cases of low FRET efficiency.

Sensitized emission of GFP2-YFP FRET pairs GFP2 excitation GFP2 emission GFP2 excitation YFP emission YFP excitation YFP emission YFP (sensitized emission) YFP (direct excitation) GFP2+YFP Coexpression GFP2-YFP linked Data are shown after linear unmixing of the GFP2 and YFP emission signals.

Comparison of CFP/YFP and GFP2/YFP FRET pairs - 32% increased overlap of donor emission and acceptor excitation - Higher absorbance and quantum efficiency of the donor - Higher Foerster Radius (approx. 5.5 nm) - Increased FRET efficiency, especially at longer distances - Suitable for donor photobleaching - However: Linear unmixing of the strongly overlapping emission signals required

ALMF: Rainer Pepperkok Jens Rietdorf Stefan Terjung GFP2/YFP project: Andreas Girod Virginie Georget Spectral imaging and linear un-mixing enables improved FRET efficiency with a novel GFP2 -YFP FRET pair T. Zimmermann, J. Rietdorf, A. Girod, V. Georget, R. Pepperkok, FEBS Letters 531 (2002)245-249 http://www.embl.de/almf/ http://www.embl.de/eamnet/

Literature T. Förster (1946): Naturwissenschaften 6, 166 T. Förster (1948): Ann. Phys. (Leipzig) 2, 55 A. Miyawaki, J. Llopis, R. Heim, J. M. McCaffery, J. A. Adams, M. Ikura and R. Y. Tsien (1997): Nature 388, 882-887. B.A. Pollok and R. Heim (1999): Trends in Cell Biology 9, 57-60. P.J. Verveer, F.S. Wouters, A.R. Reynolds, P.I. Bastiaens (2000): Science 290, 1567-1570 F.S. Wouters, P. J. Verveer and P. I. H. Bastiaens (2001): Trends Cell Biol 11, 203-211. T. Zimmermann, J. Rietdorf, A. Girod, V. Georget, R. Pepperkok (2002): FEBS Letters 531, 245-249