IMPORTANT: BEFORE INSTALLING ANY HEATING TERMINAL UNIT TO A DOMESTIC WATER HEATER, CONSULT THE LOCAL PLUMBING CODES.



Similar documents
The space saving solution.

Fan Convector Technical Specifications January 2006 Rev A

TWIN-FLOIII HEATER INSPECT THE SHIPMENT IMMEDIATELY WHEN RECEIVED TO DETERMINE IF ANY DAMAGE HAS OCCURRED DURING SHIPMENT.

INSTALL INSTRUCTIONS KK-C-HVAC-1 HVAC UNIT CHEVROLET/GMC VANS FOR

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS & HOME OWNERS MANUAL EEMAX ELECTRIC TANKLESS WATER HEATERS IMPORTANT SAFETY INFORMATION

INSTALLATION INSTRUCTIONS GEO-BOOSTER TM

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

Contractors Guide Central Inverter System Installation

Your safety and the safety of others are very important.

INSTALLATION INSTRUCTIONS & HOME OWNERS MANUAL ECO 18 ECO 24 ECO 27 IMPORTANT SAFETY INFORMATION

Digi-Motor Installation Guide

E2 Series Electric Furnaces

ELECTRIC CONVECTION BUILT-IN OVEN

OVEN PARTS For Models:GSC308PJB05, GSC308PJQ05, GSC308PJT05, GSC308PJS05 (Black) (White) (Biscuit) (Black Stainless)

I N S T ALLATION INSTRUCTIONS & HOME OWNERS MANUAL IMPORTANT SAFETY INFORMATION

Heating, Ventilation, Air Conditioning and Refrigeration (HVACR)

Oil and Coolant Circulating Heating System. Model - OCSM

Cooling Capacity CFM in. w.c. (125 Pa)

PART 8: FIELD WIRING. n WARNING NOTICE. Boiler Manual

TABLE 1. Rugged cast aluminum alloy casing,celcon waterways with nichrome parts White (unless stainless steel housing)

Owner Retain this manual in a safe place to provide your serviceman information if it becomes necessary.

Ceiling Mount Air Handler Manual

Heat Surge Model X5C Fire Place Insert Service Manual Applies to all units w/ circuit board

Roof Top Air Conditioner INSTALLATION AND OPERATING INSTRUCTIONS

WMSLW / WMBLWH Series Hydronic Upflow/Horizontal Left or Right, Heating and Cooling Air Handler

RECON WATER HEATER INSTALLATION FORM

Commercial Gas Furnace Upflow

COMMERCIAL GAS DRYER

INSTALLATION AND OPERATION INSTRUCTIONS - (LOW FLOW MODELS) (Before installation, compare electrical needed for the model of heater selected)

USER MANUAL WARNING! CONTENTS MODEL 1 SPECIFICATIONS READ ALL INSTRUCTIONS BEFORE PROCEEDING. Non-Programmable Single Stage Heat/Cool Thermostat

EVANS ELECTRONIC TEMPERATURE CONTROL TROUBLESHOOTING GUIDE for systems equipped with electric coolant valve and external PC board.

Gas Unit Heaters Duct Furnaces Horizontal - 60 HZ Form No. LF (10/2011) LF24 Standard

VC Series Zone Valves BALANCED 2-WAY AND 3-WAY HYDRONIC VALVES

Installation Instructions

Service manual. Website: CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL.

SHOWER WATER HEATER MODEL BS 35 / 45 / 60 BS 35 E / 45 E / 60 E OPERATION AND INSTALLATION INSTRUCTIONS

INSTRUCTION MANUAL A REVISION A. Series E1 and E3 Instant Hot Water Recirculating Systems

DTM04 TANK MONITOR DTM08 TANK MONITOR Dtm12 TANK MONITOR. Installation and Operation Manual

SET1E. Installation & User Instructions. Electronic timeswitch for heating & hot water. Certification Mark

Installation and User Instructions Unvented Electric Storage Water Heater Models: S10UNV, S15UNV.

NO-FROST CUSTOMER SUPPORT INFORMATION INFORMATION ON THE NO-FROST TECHNOLOGY WHITE GOODS

Water Fired Chiller/Chiller-Heater. WFC-S Series: 10, 20 and 30 RT Cooling

THERMOSTATIC MIXING VALVE TRIM K-T9493, K-T9494

BATHROOM HEATER. User's Manual. Page 2...A515 Page 9...A716

UB1 AIR CONDITIONING UNIT INSTALLATION INSTRUCTIONS

CARING FOR YOUR WATER HEATER

SECTION HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT

OVEN PARTS For Models:GMC305PDB07, GMC305PDQ07, GMC305PDT07, GMC305PDS07 (Black) (White) (Biscuit) (S.Steel)

Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp.

All work must conform to the National Electric Code, latest edition, and all other applicable codes and regulations.

SECTION FIRE AND SMOKE ALARM SYSTEM. City of San Diego, CWP Guidelines

Overnight Sensations Speaker Kit


Installation and User Instructions Aquarius Undersink Vented Water Heaters Models: AU7/3, AU7/1, AU10/3, AU10/1.

INSTALLATION INSTRUCTIONS COMMERCIAL ROOM VENTILATORS WITH EXHAUST

COMMERCIAL GAS DRYER

OASIS-PLUS 120V READ ALL INSTRUCTIONS BEFORE OPERATING READ ALL INSTRUCTIONS BEFORE OPERATING OZONE IS A POWERFUL OXIDIZER AND MUST BE USED WITH CARE

TECHNICAL SERVICE DEPARTMENT Technical Service Bulletin Tankless Electric (RTE) Troubleshooting

Explosion-Proof Electric Unit Heaters

Pre-Fab Easy Installation For Models: 006-CT-USK, 008-CT-USK Installation and Operating Instructions for Existing Homes with Standard Piping

Installation and maintenance instructions. Danfoss Vent

SERVICE MANUAL RESIDENTIAL ELECTRIC AND LIGHT DUTY COMMERCIAL ELECTRIC WATER HEATERS. Troubleshooting Guide and Instructions for Service

LIEBERT VNSA Installation Sheet

Auxiliary HVAC RAM ProMaster. Standard Tie-in Extreme Climate System

Low Profile Unit Cooler

Installation and Troubleshooting Instructions for Electric Tankless Residential Water Heaters.

GENERAL SUPPLEMENT 410. Radiantec CONTROLS FOR RADIANT HEATING CONTROLS PURPOSE OF RADIANTEC CONTROLS

Use & Care Manual. Electric Tankless Water Heaters. With Installation Instructions for the Installer AP15447 (10/10)

The Ultimate Truck Stock Motor

HM-W536 Install Guide

TS93 EMR T/PT/TDE. Surface applied door closer

Instruction / Installation Sheet DataComm Electronics WH-KIT Flat Panel TV Cable Organizer Kit with Duplex Power Solution

OWNER S GUIDE OPERATION & INSTALLATION

specializing in AIR CONDITIONING, PARTS AND SYSTEMS for your classic vehicle PERFECT FIT IN-DASH HEAT/ COOL/ DEFROST CHEVROLET PICKUP

Installation Instructions

Cooling system components, removing and installing

Installer s Guide WARNING: 18-GJ11D1-2. Ultraviolet (UV-C) Lamp Kit for 2-5 Ton Air Handlers HAZARDOUS VOLTAGE - DISCONNECT POWER BEFORE SERVICING

TANKLESS WATER HEATER INSTALLATION DIAGRAMS

WON0502-B INSTALLATION INSTRUCTIONS FOR ELECTRIC FURNACES. Bulletin / March 2013

36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve

SF15K SF05KSS, SF10KSS

prestige Condensing Water Boiler SERVICE TECHNICIAN S TROUBLE SHOOTING GUIDE TSG-PRESTIGE Date revised: 12/6/10

Andersen Electric Window Opener for Andersen Awning and Roof Windows

Installation Manual. Thermomax Solar Water Heater ... Installation Procedure for Flatroof and Ground. Revision 8

Installation Instructions

Install Guide CT100. Caution. Caution ENGLISH. disconnect the power supply before beginning work.

COMMERCIAL GAS DRYER

A&A CORVETTE PERFORMANCE C6 BOOST & FUEL GAUGE INSTALLATION INSTRUCTIONS

High kw Electric Tankless Water Heater Troubleshooting Guide

Air Conditioner Water Heater - A Product of HotSpot Energy LLC

Cooling Capacity CFM in. w.c. (125 Pa)

PERFECT FIT SERIES IN-DASH HEAT/ COOL/ DEFROST 1967 CHEVROLET IMPALA

Providing Temperature. Regulated Warm Water. to your Sanicare. Hand Spray Bidet

I N S T A L L A T I O N I N S T R U C T I O N S F O R T H E H i l k o i l Energy S aving Hot Water Kit

Cooktop Low-Profile Ventilation Hoods

Volkswagen B3 Passat General-Engine 4 CYL. 19 Engine - Cooling System (Page GR-19)

SET3M. electro-mechanical 24 programmer for heating & hot water. Installation & User Instructions

Cooling system components, removing and installing

Installation Instructions

Transcription:

QUIET-ONE Environmental Products 2000 Kickspace Heater Series Models: KS 2004, KS 2006 KS 2008, KS 2010 INSTALLATION OPERATING MAINTENANCE Please read these instructions thoroughly before beginning your installation! Smith s Quiet-One 2000 Series kickspace heaters are designed for installation in a forced hot water (hydronic) heating system. They may also be used with conventional gas, oil, electric, or solar powered water heaters. IMPORTANT: BEFORE INSTALLING ANY HEATING TERMINAL UNIT TO A DOMESTIC WATER HEATER, CONSULT THE LOCAL PLUMBING CODES. When installing a kickspace heater, an accurate heat loss calculation of the space is required. Match unit selection with BTUH output at system water temperature and flow rate. See the capacity chart below for output at various water temperatures and flow rates. Flow Rate Pressure Entering Water Temperature (in degrees F) - BTU/hrs. Unit GPM Drop (ft) 130 140 150 160 170 180 190 200 210 1.06 2095 2410 2700 3000 3350 3650 3860 4000 4105 KS 2004 3.422 2240 2650 3000 3350 3765 4350 4350 4530 4635 5 1.026 2350 2755 3140 3530 3940 4590 4590 4810 4935 1.12 3410 4050 4655 5265 5860 6700 6700 7110 7270 KS 2006 3 1.19 3735 4395 5060 5735 6330 7120 7120 7530 7790 5 2.6 3860 4540 5225 5910 6560 7415 7415 7800 8010 1.12 4300 5000 5765 6500 7370 8400 8400 8735 8920 KS 2008 3 1.19 4580 5380 6195 7050 7930 9010 9010 9445 9740 5 2.6 4760 5625 6450 7290 8200 9360 9360 9785 10020 1.41 5530 6350 7150 7975 8780 9975 9975 10330 10520 KS 2010 3 2.78 5880 6710 7740 8710 9625 11060 11060 11530 11740 5 3.92 6070 7030 8000 9030 10025 11525 11525 11995 12180 All capacities are rated by RTS with the kickspace installed under a cabinet and all capacities include the heat effect factor. For low speed ratings use:.85 for the KS2004,.75 for the KS2006,.70 for the KS2008 and.65 for the KS2010. Heat throw: KS2004 = 10 @ 50 CFM; KS2006 = 10 @ 75 CFM; KS2008 = 10 at 90 CFM; KS2010 = 10 @ 125 CFM. NOTE: All kickspace heaters include a low limit aquastat which shuts off power to the fan when water temperature falls to 110 o F. Power is restored when water temperature rises to 130 o F. When installing units with low temperature systems (radiant or water heater), it may be necessary to change the aquastat to a special (90 o /110 o F) low temperature unit (part #S10046). UNIT INSPECTION Before starting the installation, carefully remove the kickspace heater from its box. Inspect for any damage caused in handling. The box should include: (1) Kickspace unit (2) Molded grille endcaps (KS 2004 only) (2) Mounting screws (2) Screw covers LOCATING THE KICKSPACE HEATER Quiet-One 2000 Series kickspace units are designed for installation under kitchen cabinets, bathroom vanities, built-in shelves or benches, and stairways. An available recessed wall mounting kit enables vertical installation with a flush mounted grille. Consideration should be given in regards to perishable goods stored in the cabinet above the unit.

PREPARING THE SITE Once the location has been selected, it will be necessary to cut a 15 X 15 opening in the bottom shelf of the cupboard. This piece should be saved for replacement after installation, and may be hinged to ease access to the unit. NOTE: WHEN USING THE QUICK FIT HOSE KIT ACCESSORY ITEM, THIS STEP IS NOT REQUIRED. REFER TO SEPARATE SHEET FOR INSTRUCTIONS. The front kickboard must be cut to the A and B dimension listed for each unit. The box that your kickspace heater came in has a handy template to ensure accurate cuts. Holes must be drilled in the floor or back wall of the cabinet to allow for supply and return piping (1/2 ) and electrical connection. A B KS 2004 14 3 1/2 KS 2006 18 1/2 3 1/2 KS 2008 18 1/2 3 1/2 KS 2010 22 1/8 3 13/16 INSTALLING THE KICKSPACE HEATER Place the molded grille endcaps on either side of the grille (KS 2004 only). Slide the kickspace unit backwards into the opening in the kickboard until the endcaps and grille are flush with the finished surface of the kickboard. Secure the unit with screws provided through holes in the endcaps (or grille), and place screw covers over the screws. Check to ensure that unit is both secure and level. NOTE: UNLIKE COMPETITIVE MODELS, IT IS NOT NECESSARY TO SCREW THE QUIET-ONE UNITS TO THE FLOOR. KS 2004 KS 2006, 2008, 2010 PIPING Water supply and return connections are 1/2 copper tube. The water supply is the bottom tube and must be soldered first. After soldering the return connection (top tube), check that both connections are leak free. NOTE: ISOLATION VALVES ARE RECOMMENDED ON BOTH SUPPLY AND RETURN PIPING TO ALLOW FOR SERVICE AND BALANCING IF NECESSARY. When filling the kickspace unit with system water, it will be necessary to remove the air from it. A built in bleeder air vent is accessible through the front of the unit by removing the rubber grommet. This vent may be operated with a screwdriver through the grille. Be careful as some water may be bled along with air. See diagrams for recommended piping arrangements.

Piping Diagrams Two Pipe Reverse Return One Pipe Series Loop (Note: Monoflo fittings may be required) Water Heater As A Source

Replacement Parts Part Description Replacement Part Number KS 2004 KS2006 KS 2008 KS 2010 1 Coil S10007 S10123 S10123 S10126 2 + Grille S10008 S10130 S10130 S10131 3 * Fan motor S10009 S10124 S10125 S10127 4 * Outboard bearing S10010 S10010 S10010 S10010 5 * Blower wheel S10011 S10011 S10011 S10128 6 ** Aquastat S10012 S10012 S10012 S10012 7 Rocker switch S10013 S10013 S10013 S10013 + Grille parts for the KS 2004 are the end caps only. * Available as a complete unit (KS 2004-10229; KS 2006-10230; KS 2008-10231; KS 2010-10232). ** Available as a kit (Part #S10028-110 o F-130 o F) (Part #S10046-90 o F -110 o F) Environmental Products

ELECTRICAL CONNECTIONS ALL ELECTRICAL CONNECTIONS MUST COMPLY WITH LOCAL AND/OR NATIONAL REGULATIONS. IF IN DOUBT, CONSULT A QUALIFIED ELECTRICIAN. Smith s Environmental Products kickspace heaters are UL approved. Remove the electrical junction box cover through the screw provided. There are two knockouts in the back and side of the junction box. Select the most convenient and bring wiring through it. Supply conductors should be 14 AWG and protected by a 15 AMP over current protector. Connect line input to black lead, neutral to white lead, and ground to pillar marked G inside the junction box. Refer to diagram below for complete wiring instructions. Internal Wiring Diagram 120V-60HZ ph A.C. supply white low limit thermostat white fan motor Ground Pillar G black red boost off yellow normal Field wiring enclosure control switch OPERATION Before replacing the access cover in the cabinet bottom, ensure that the unit is operating properly. Activate the system thermostat and place speed switch on the front of the kickspace unit on MIN. Because of the low limit aquastat, it may take several minutes before the fan is activated. When the fan does come on, ensure that the switch is operational by moving position to OFF, then MAX. Best results are obtained by leaving the switch in the MIN position and reserving MAX for quick heat up or extreme conditions. If the unit is not operating, see troubleshooting tips at the end of this manual. UNIT MAINTENANCE The Quiet-One 2000 Series kickspace heaters are designed for years of trouble free operation with very little maintenance. It is recommended however that the unit be vacuumed occasionally through the front grille. This is especially important in areas with lots of dust, pet hair and dirt. If servicing is required beyond this, contact the installing contractor or Smith s Environmental Products Customer Service 1875 Dewey Ave. Benton Harbor, MI 49023 (269) 925-8818 www.smiths-env.com TROUBLESHOOTING TIPS If the kickspace heater fan does not operate: 1. Verify that supply voltage is 120 VAC, all wires are connected, and fan switch is in MIN or MAX position. 2. Verify that hot water is going to and through the unit at 130 o F or above. Both supply and return pipes should be hot. An air bound coil will prevent the fan from operating. Bleed air from the coil if necessary. 3. By pass the low limit aquastat using a jumper wire. If the fan now runs, replace the aquastat. 4. If the fan does not run while the aquastat is jumped, replace the motor assembly.