Fan Convector Technical Specifications January 2006 Rev A
|
|
|
- Camron Ray
- 9 years ago
- Views:
Transcription
1 Boost Off Normal Off Fan Convector Technical Specifications Boost Normal January 2006 Rev A Boost Off Normal Whispa II Whispa 50 Whispa E Hi-Line Lo-Line Lo-Line HC Slim-Line CSU
2 Hydronic Fan Convectors Fan Convectors are designed to provide heat in a minimum of space using forced convection. s efficient tangential fan design forces air uniformly across a low pressure drop heat exchanger, resulting in a high heat output from a very compact space. Fan Convectors all have several features in common: Fan bearings are porous bronze sleeves for longer life and quieter service Heat exchangers feature copper tubing expanded onto aluminum fins for greater heat transfer efficiency Each model has been certified by independent testing by ATL* to deliver 100% of the published heat output Each unit is manufactured to the high standards of s certification Each unit comes with at least a 3 year warranty; coverage for heat exchangers is extended to 10 years Technical specifications for the Fan Convector family are given on the following pages, showing specific dimensions and configuration, heat output, weights and head requirements. COMPARISON OF MAJOR FEATURES Whispa II Whispa II Whispa II Whispa 50 Whispa E Hi-Line Lo-Line Lo-Line HC Slim-Line CSU Kickspace Recessed Wall Recessed Floor Kickspace Kickspace Fan Fan Fan Fan Heater Heater Heater Heater Heater Convector Convector Convector Convector Page Fan Unit Bearings Controls 2 Speed 2 Speed 2 Speed 2 Speed 2 Speed 2 Speed 3 Speed 3 Speed 3 Speed 2 Speed Heat Exchanger Construction Zinc-coated, Zinc-coated, Aluminum with Zinc-coated, Zinc-coated, Zinc-coated, Zinc-coated, Zinc-coated, Zinc-coated, Zinc-coated, painted steel, painted steel, mild steel grill & hardened painted steel painted steel painted steel painted steel painted steel epoxy/polyester hardened hardened epoxy/polyester aluminum grill, baked-on finish aluminum grill, aluminum grill, baked-on finish epoxy/polyester epoxy/polyester epoxy/polyester baked-on finish baked-on finish baked-on finish Water 1/2" Sweat 1/2" Sweat 1/2" Sweat 1/2" Sweat 1/2" Sweat 1/2" Sweat 1/2" Sweat 1/2" Compression 1/2" Sweat Connections Right Rear Corner Bottom Left Corner Side Right Rear Corner Upper Right Lower Left Corner Lower Left Corner Lower Left Corner Upper Left Corner Electric Rear 110V Rear 110V Rear 110V Rear 110V Left Rear 110V Right Rear 110V Right Rear 110V Right Rear 110V Right Rear 110V Connections 60Hz 60Hz 60Hz 60Hz 60Hz 60Hz 60Hz 60Hz 60Hz Tamper- Proof Cover Warranty 10 Year 10 Year 10 Year 10 Year 10 Year 10 Year 10 Year 10 Year 10 Year 10 Year Heat Exchanger, Heat Exchanger, Heat Exchanger, Heat Exchanger, Heat Exchanger, Heat Exchanger, Heat Exchanger, Heat Exchanger, Heat Exchanger, Heat Exchanger, 3 Year Fan Motor 3 Year Fan Motor 3 Year Fan Motor 3 Year Fan Motor 3 Year Fan Motor 3 Year Fan Motor 3 Year Fan Motor 3 Year Fan Motor 3 Year Fan Motor 3 Year Fan Motor Approvals Certifications ATL Certified* ATL Certified* ATL Certified* ATL Certified* ATL Certified* ATL Certified* ATL Certified* ATL Certified* ATL Certified* ATL Certified* BTU Range** W 5000 FM WH 50 EWH HC SL 16 CSU-10M 4,247-6,188 3,736-5,308 4,279-6,010 2,583-3,167 2,731-5,462 11,143-18,600 13,852-21,398 13,738-21,324 9,072-15,293 5,319-7, W HC CSU-15M 8,639-10,875 6,522-9,571 8,688-15,542 11,873-17,458 11,896-17,504 7,317-10, HC 9-6 CSU-23M 6,461-9,640 8,917-11,363 9,038-11,506 9,518-16, HC 6-4 3,666-5,156 4,986-6,976 5,001-6,899 *ATL = Automated Test Labs, Philadelphia, PA **Based on entering water temperature of 3GPM meets the highest quality manufacturing standards. Myson, Inc
3 Boost Off Normal Boost Off Normal WHISPATM II A New Generation in Kickspace Heaters WHISPA II KICKSPACE HEATER CERTIFIED BTU/HR OUTPUT ENTERING 65 F MODEL FLOW RATE FAN AIR DELIVERY # GPM SPEED CFM WH II Boost 93 Normal Boost 93 Normal 62 WH II Boost 134 Normal Boost 134 Normal 95 reserves the right to make changes or improvements to our products which may affect these specifications. NOTE: For proper sizing, use the rating at normal speed. ENTERING WATER TEMPERATURE ( F), OUTPUT (BTU/hr) 110** 120** 130** ,744 2,240 2,737 3,234 3,731 4,228 4,724 5,310 5,718 6,215 1,496 1,889 2,282 2,675 3,068 3,461 3,853 4,247 4,639 5,032 2,057 2,643 3,229 3,815 4,401 4,987 5,573 6,188 6,745 7,331 1,667 2,105 2,543 2,980 3,418 3,856 4,293 4,730 5,169 5,606 4,090 4,999 5,907 6,815 7,723 8,631 9,539 10,431 11,356 12,264 3,246 4,026 4,806 5,585 6,365 7,145 7,925 8,639 9,485 10,265 4,269 5,217 6,165 7,113 8,060 9,008 9,956 10,875 11,852 12,799 3,403 4,221 5,038 5,856 6,674 7,491 8,309 9,055 9,944 10,762 **For output at these water temperatures, optional 107 F low temperature cut-off required. HEAT OUTPUT 180 F WATER TEMP MODEL FLOW RATE FAN BASEBOARD C.I. RADIATORS # GPM SPEED (525 BTU/FT) (225 BTU/SQ FT) WH II Boost/Normal 11.7 ft / 9.0 ft 27 sq ft / 21 sq ft WH II Boost/Normal 20.8 ft / 17.4 ft 49 sq ft / 41 sq ft MODEL UNIT WEIGHT # WEIGHT PACKED WH II WH II MODEL FLOW RATE FT WG # GPM WH II / / 1.20 WH II / / 2.77 WH II 5000 Kickspace Heater Electrical Panel Cover WH II 9000 Kickspace Heater Electrical Panel Cover 12 1 /8" and return piping 16" and return piping 14 1 /4" Top View 17 3 /4" Top View 4" 19 3 /4" 4" Front View Grill 23 3 /4" Front View Grill 8" 12 1 /8/ " Side View " 16" Side View WHISPA II KICKSPACE FAN CONVECTOR SPECIFICATIONS Engineered to be efficient. Controls... Units have a two-speed Boost/Off/Normal fan switch. For installations without a separate thermostat, all models have low-limit thermostats which close at 129 F and reopen at 109 F (±7 F). from zinc-coated painted steel. The grill is hardened aluminum with a baked epoxy polyester finish for strength and durability. Available in black or white. Warranty... offers a full ten year Myson, Inc
4 Boost Normal MonoFlo Tees Simple and easy installation Off For installation detail, see MonoFlo or One Pipe System on page 13. EZ-HoseTM Kit Flexible Hose Connectors s EZ-Hose kit is specifically designed for installation with Fan Convectors. It allows the unit to be easily removed from the cabinet for quick connection and easy-access maintenance. These flexible hoses can save time and money, and they quickly solve those difficult access problems. EZ-Hose Kit... save time and money. s hose kit is so easy to use. The flexible hoses allow you to install the Fan Convectors from outside the cabinet. There s no need to remove the cabinet or cut ugly access doors in the bottom of the cabinet. EZ-Hose Kit... easy access installation. s two-hose system installs in minutes. Two MonoFlo tees (not included in kit) are installed in the heating loop. The hoses are then used to connect the convector to the heating loop. EZ-Hose Kit... maintenance is hassle-free. If you should need to service the Fan Convector, the EZ-Hose has an ample 30 inches of flexible hose so you can slide the unit completely out for maintenance. The Ball Valve with the slotted shut-off, enables you to disconnect the unit while maintaining the pressure of the system and you do not have to drain the system. Features: Flexible Designed with installation in mind, these 30" hoses with a 1 /2" female compression fitting on one end and a ball valve with screwdriver slot on the other end, provide enough length to allow installation outside of the cabinet. Tested Maximum operating temperature of 250 F and working pressure of 100psi. Easy Installation Installs in a fraction of the time required for conventional pipe installation... that saves time and money. Backed with confidence guarantees 100% satisfaction. Compatibility May be used with both water- and antifreezeprotected heating systems. 2 Myson, Inc
5 WHISPATM Recessed Wall Heaters WHISPA II RECESSED WALL HEATER CERTIFIED BTU/HR OUTPUT ENTERING 65 F MODEL FLOW RATE FAN AIR DELIVERY # GPM SPEED CFM WH II 5000W 1.0 Boost 93 Normal Boost 93 Normal 62 WH II 9000W 1.0 Boost 134 Normal Boost 134 Normal 95 reserves the right to make changes or improvements to our products which may affect these specifications. NOTE: For proper sizing, use the rating at Normal speed. II ENTERING WATER TEMPERATURE ( F), OUTPUT (BTU/hr) 110** 120** 130** ,728 2,139 2,555 2,976 3,400 3,827 4,257 4,689 5,125 5,562 1,393 1,721 2,051 2,384 2,719 3,056 3,396 3,736 4,079 4,422 2,008 2,472 2,939 3,409 3,881 4,354 4,830 5,308 5,786 6,267 1,619 1,988 2,359 2,731 3,104 3,478 3,853 4,229 4,605 4,983 3,068 3,805 4,553 5,309 6,072 6,842 7,618 8,400 9,186 9,977 2,417 2,988 3,566 4,149 4,736 5,328 5,923 6,522 7,123 7,728 3,558 4,396 5,244 6,098 6,958 7,825 8,696 9,571 10,451 11,335 2,717 3,356 4,001 4,652 5,307 5,966 6,628 7,294 7,963 8,635 **For output at these water temperatures, optional 107 F low temperature cut off required. HEAT OUTPUT 180 F WATER TEMP MODEL FLOW RATE FAN BASEBOARD C.I. RADIATORS # GPM SPEED (525 BTU/FT) (225 BTU/SQ FT) WH II 5000W 3.0 Boost/Normal 10.1 ft / 8.1 ft 24 sq ft / 19 sq ft WH II 9000W 3.0 Boost/Normal 18.2 ft / 13.9 ft 43 sq ft / 32 sq ft MODEL UNIT WEIGHT # WEIGHT PACKED WH II 5000W WH II 9000W MODEL FLOW RATE FT WG # GPM WH II 5000W 1.0 / / 1.20 WH II 9000W 1.0 / / 2.77 WH II 5000 Recessed Wall Heater WH II 9000 Recessed Wall Heater 17 3 /4" WH II 5000 Recessed Wall Heater 17 3 /4" WH II 9000 Recessed Wall Heater 3 5 /8" 14 3 /8" 3 /8" 3 5 /8" /16" 3 /8" Top View Top View 14 1 /2" 18 1 /4" Wall Opening Wall Opening Air Vent Screw Additional Fixing Holes for 9000 Model (2 at top and bottom) Fixing Holes 3 each side Electrical Panel Cover Fixing Screws (8 offset) 19 1 /8" 16 1 /2" Front View Grill 19 1 /8" 19 1 /2" Front View Grill Piping Entry Wiring Entry 3 /4" 1 3 /8" 1 /8" 1 3 /8" Back View Front Cover 1" Piping 2 3 /4" 3 /4" Piping 2 3 /4" Wiring Bottom View Wiring Bottom View WHISPA II RECESSED WALL FAN CONVECTOR SPECIFICATIONS Engineered to be efficient. Controls... Units have a two-speed Boost/Off/Normal fan switch. For installations without a separate thermostat, all models have low-limit thermostats which close at 129 and reopen at 109 ( ± 7 F). from zinc-coated painted steel. The grill is hardened aluminum with a white, baked epoxy polyester finish for strength and durability. Warranty... offers a full ten year Myson, Inc
6 WHISPATM II A Recessed Floor Fan Convector WHISPA II 5000 RECESSED FLOOR FAN CONVECTOR BTU/HR HEAT OUTPUT ENTERING 65 F MODEL FLOW RATE FAN SPEED AIR DELIVERY # GPM (CFM) Whispa II 1.0 Boost FM Normal 62 Whispa II 3.0 Boost FM Normal 62 NOTE: For proper sizing, use the rating at Normal speed. ENTERING WATER TEMPERATURE ( F) 110* 120* 130* ,995 2,473 2,957 3,447 3,941 4,440 4,942 5,448 5,957 6,469 1,597 1,972 2,350 2,731 3,115 3,601 3,889 4,279 4,671 5,064 2,200 2,728 3,262 3,803 4,348 4,898 5,462 6,010 6,572 7,136 1,762 2,175 2,592 3,013 3,436 3,862 4,290 4,721 5,153 5,587 *For output at these water temperatures, optional 120 F low temperature cut-off required. HEAT OUTPUT 180 F WATER TEMP MODEL FLOW RATE FAN SPEED BASEBOARD C.I. RADIATORS # GPM (525 BTU/FT) (225 BTU/SQ FT) WHISPA II 1 Boost/Normal 10.4 ft / 8.2 ft 24 sq ft / 19 sq ft 5000 FM 3 Boost/Normal 11.4 ft / 9.0 ft 26 sq ft / 21 sq ft MODEL UNIT WEIGHT # WEIGHT PACKED WHISPA II 5000 FM 15 lbs 18 lbs WHISPA II 5000 GAL/MIN (GPM) FT WG /16" Flange Depth 9 5 /8" Flange Width 9 7 /16" 3 /4" Electrical Knockout 9 7 /16" 3 3 /4" 2 1 /4" 1 /2" Connection 1 /2" Connection 1 5 /8" 14 1 /4" 5 /8" 14 1 /4" Connections 1 5 /8" 8 1 /4" Dimensional View 9 3 /4" 15 7 /8" Grill NOTE: All connections accessible from the top of the unit. WHISPA II 5000 RECESSED FLOOR FAN CONVECTOR SPECIFICATIONS Engineered to be efficient. Controls... Units may be wired to a wall switch or thermostat. All models have low-limit thermostats which close at 129 F and reopen at 109 F (±7 F). Optional low temperature thermostat is available. from aluminum. The grill is mild steel with a baked epoxy polyester finish for strength and durability. Available in classic beige. Warranty... offers a full ten year 4 Myson, Inc
7 Boost Off Normal WHISPATM 50 Kickspace Heaters from WHISPA 50 FAN CONVECTOR BTU/HR HEAT OUTPUT ENTERING 65 F MODEL FLOW RATE FAN SPEED AIR DELIVERY # GPM CFM WH Boost 46 Normal Boost 46 Normal 38 reserves the right to make changes or improvements to our products which may affect these specifications. NOTE: For proper sizing, use the rating at Normal speed. KICKSPACE 180 F WATER TEMP MODEL GPM SPEED BASEBOARD C.I. RADIATORS # (525 BTU/FT) (225 BTU/SQ FT) WH 50 3 Boost / Normal 6.0 ft / 5.3 ft 14 sq ft ENTERING WATER TEMPERATURE ( F) 110** 120** 130** ,135 1,372 1,606 1,839 2,070 2,299 2,527 2,754 2,980 3,204 3, ,145 1,377 1,612 1,850 2,093 2,336 2,583 2,833 3,083 3,336 1,305 1,578 1,847 2,115 2,380 2,644 2,906 3,167 3,427 3,685 3, ,225 1,473 1,725 1,980 2,239 2,500 2,764 3,031 3,299 3,570 **For output at these water temperatures, optional 107 low temperature cutoff required. MODEL UNIT PACKED # WEIGHT WEIGHT WH GAL/MIN(GPM) FT. WG Electrical Panel Cover and return piping 7 1 /2/ " 14" Top View 3" Grill 7 1 /2/ " Side View WHISPA 50 KICKSPACE FAN CONVECTOR SPECIFICATIONS Engineered to be efficient. Controls... Units have a two-speed Boost/Off/Normal fan switch. For installations without a separate thermostat, all models have low-limit thermostats which close at 129 F and reopen at 109 F (±7 F). from zinc-coated painted steel. The grill is hardened aluminum for strength and durability. Warranty... offers a full ten year Myson, Inc
8 DO NOT COVER DO NOT COVER IMMEDIATELY DISCONNECT FROM THE MAINS BEFORE REMOVING THIS COVER WHISPATM E Electric Kickspace Heater from WHISPA E KICKSPACE HEATER COMPARISON TO BASEBOARDS & RADIATORS* BASEBOARD C.I. RADIATORS MODEL SETTINGS V/Hz WATTS BTUs AMPS (525 BTU/FT) (225 BTU/SQ FT) EWH High 110V/60Hz , ft sq. ft. Low 110V/60Hz 800 2, ft sq. ft. *For comparison, a water temperature of 180 F has been assumed. NOTE: For proper sizing, use the rating at Medium or Low speeds. A Width 20" B Height 4" (min.) C Depth 16" D Base Shelf Overhang 1" INSTALLATION DIMENSIONS A B D Be sure to provide sufficient space around the unit to allow for adequate air circulation. C UNIT WEIGHT UNIT WEIGHT MODEL WEIGHT PACKED EWH 8.1 lbs 10 lbs CONTROLS Power/Fan Settings: OFF ON Indicated by red light. Heater Settings: OFF LOW (Either Position) HIGH WHISPA E KICKSPACE HEATER DIMENSIONS Model # EWH " 14" WHISPA-E FACE 4" 8 7 8" WHISPA-E " WARNING PLINTH HEATER WHISPA-E VOLTS-120VAC. 60 HZ AMPS-13 WATTS-1600 MADE IN THE U.K. USE ONLY ON 20 AMPERE BRANCH CIRCUIT Front view with unit height " Top view WHISPA E ELECTRIC KICKSPACE HEATER SPECIFICATIONS Engineered to be efficient. Fan Unit... A highly efficient 110 cfm tangential fan extends the full width of the heating element, giving extremely quiet, trouble-free operation. All units have aluminum fans, sealed motor bearings, and permanently lubricated bearings. Controls... Units have a lighted fan switch to indicate power ON. Heat is controlled using a dual rocker switch both switches OFF for fan only, either switch ON for 800 Watts (Low), and both switches ON for 1600 Watts (High). Each unit has a high temperature limit switch to shut off power in the event of excessive temperature resulting from restricted airflow. 6 Myson, Inc from zinc-coated painted steel. The grill is hardened aluminum for strength and durability. Electrical connections... Wiring connections are supplied through the rear of each unit. Motor is 110V, 60Hz and is ETL listed. Dual heating elements draw a total of 15 amps on the high setting.
9 Hi-LineTM Fan Convector from HI-LINE FAN CONVECTORS BTU/HR HEAT OUTPUT ENTERING 65 F MODEL FLOW RATE FAN SPEED AIR DELIVERY # GPM1 CFM Boost 197 Normal Boost 164 Normal Boost 106 Normal Boost 55 Normal 34 ENTERING WATER TEMPERATURE ( F) 110** 120** 130** ,940 8,569 10,213 11,870 13,538 15,217 16,904 18,600 20,303 22,013 4,141 5,118 6,104 7,099 8,101 9,109 10,123 11,143 12,168 13,197 5,778 7,140 8,516 9,903 11,300 12,706 14,120 15,542 16,970 18,405 3,224 3,985 4,755 5,531 6,313 7,100 7,892 8,688 9,488 10,292 3,578 4,422 5,276 6,137 7,005 7,878 8,757 9,640 10,528 11,419 2,397 2,963 3,535 4,112 4,694 5,280 5,869 6,461 7,056 7,654 1,912 2,364 2,821 3,281 3,746 4,213 4,683 5,156 5,631 6,108 1,357 1,678 2,003 2,331 2,662 2,994 3,329 3,666 4,004 4,345 1 NOTE: Correction factor for 1.0 gpm, multiply by 0.87 **For output at these water temperatures, optional 107 low temperature cut-off required. NOTE: For proper sizing, use the rating at Normal speed. reserves the right to make changes or improvements to our products which may affect these specifications. FAN CONVECTOR 180 F WATER TEMP MODEL FLOW RATE FAN SPEED BASEBOARD C.I. RADIATORS # GPM (525 BTU/FT) (225 BTU/SQ FT) Boost/Normal 35/21 ft 83/50 sq ft Boost/Normal 30/17 ft 69/39 sq ft Boost/Normal 18/12 ft 43/29 sq ft Boost/Normal 10/7 ft 23/16 sq ft MODEL UNIT WEIGHT # WEIGHT PACKED MODEL FT WG # 1 GPM 3 GPM / 8 " 2 DIMENSIONS Water Connection 2" MODEL # A B " " " " 3 1 /8/ " Wiring Connection Top View " " " " 2 1 8" Wiring 1 1 /8" 1 /4/ " 5" 2 1 /4/ " 4 3 / 4 " 2 /4/ " 3 " 5" 7" Mounting Holes 14 1 /4/ " Pipe Wiring Pipe B NOTE: For surface mounting application only. A 5" Front View Side View NOTE: Piping and wiring openings are accessible from either top or back. Controls... Units have a two-speed Boost/Off/Normal fan switch. For installations without a separate thermostat, all models have low-limit thermostats which close at 129 F and reopen at 109 F (±7 F). HI-LINE FAN CONVECTOR SPECIFICATIONS Engineered to be efficient. from zinc-coated painted steel. Warranty... offers a full ten year Myson, Inc
10 Lo-LineTM Fan Convector from LO-LINE FAN CONVECTORS BTU/HR HEAT OUTPUT ENTERING 65 F MODEL FLOW RATE FAN SPEED AIR DELIVERY # GPM 1 (CFM) Boost Medium 179 Low 132 Boost Medium 138 Low 94 Boost Medium 69 Low 52 Boost Medium 42 Low 28 1 NOTE: Correction factor for 1.0 gpm, multiply by 0.87 NOTE: For proper sizing, use the rating at Medium or Low speeds. FAN CONVECTOR 180 F WATER TEMP MODEL FAN SPEED BASEBOARD C.I. RADIATORS # (525 BTU/FT) (225 BTU/SQ FT) Boost/Med/Low 41/33/26 ft 95/77/61 sq ft Boost/Med/Low 33/27/23 ft 78/64/53 sq ft 9-6 Boost/Med/Low 22/20/17 ft 51/46/40 sq ft 6-4 Boost/Med/Low 13/11/10 ft 31/26/22 sq ft ENTERING WATER TEMPERATURE ( F) 110** 120** 130** ,715 10,560 12,392 14,212 16,021 17,821 19,613 21,398 23,176 24,948 7,026 8,513 9,989 11,454 12,912 14,361 15,805 17,242 18,674 20,101 5,647 8,841 8,027 9,204 10,374 11,539 12,698 13,852 15,002 16,148 7,118 8,624 10,118 11,602 13,077 14,544 16,004 17,458 18,908 20,352 5,812 7,041 8,260 9,471 10,674 11,872 13,063 14,250 15,432 16,610 4,846 5,870 6,885 7,893 8,896 9,893 10,885 11,873 12,857 13,838 4,637 5,617 6,589 7,554 8,513 9,488 10,417 11,363 12,305 13,244 4,196 5,081 5,959 6,831 7,698 8,559 9,417 10,271 11,122 11,969 3,642 4,410 5,173 5,930 6,682 7,431 8,175 8,917 9,856 10,392 2,815 3,418 4,017 4,614 5,207 5,799 6,388 6,976 7,562 8,146 2,382 2,885 3,383 3,878 4,370 4,859 5,345 5,830 6,313 6,793 2,040 2,470 2,896 3,319 3,739 4,157 4,572 4,986 5,398 5,809 **For output at water temperatures below 140 F, optional 107 F low temperature cut-off required. MODEL UNIT WEIGHT # WEIGHT PACKED MODEL FT WG # 0.5 GPM 1.25 GPM DIMENSIONS A 2 1 /16" MODEL # A " " 18 1 /2" /16" 9 7 /16" Water Connections " " Front View 3 3 /16" 6" Side View Pipe Entry 1 7 / 8 " 5 1 /2" Cable Entry 1 11 /16" 2 9 /16" 4 5 /8" NOTE: For surface mounting application only. Bottom View Controls... Units have a three-speed Boost/Medium/Low fan switch and built-in thermostat. All models have low-limit thermostats which close at 129 F and reopen at 109 F (±7 F). LO-LINE FAN CONVECTOR SPECIFICATIONS - Engineered to be efficient. from zinc-coated painted steel. Tamper-Proof Controls Cover... All units include a tamper-proof controls cover which conceals all electrical controls from unauthorized usage. Warranty... offers a full ten year 8 Myson, Inc
11 Lo-LineTM HC Heating and Cooling from a Single Convector LO-LINE HC FAN CONVECTORS BTU/HR HEAT OUTPUT ENTERING 65 F MODEL FLOW RATE POWER FAN SPEED AIR DELIVERY ENTERING WATER TEMPERATURE ( F) # GPM 1 WATTS (CFM) 110** 120** 130** Boost 221 7,817 9,654 11,525 13,429 15,357 17,316 19,305 21,324 23,372 25,448 HC Medium 179 6,381 7,871 9,385 10,924 12,487 14,074 15,683 17,315 18,969 20,645 Low 132 5,064 6,246 7,447 8,668 9,908 11,166 12,443 13,738 15,049 16,374 Boost 186 6,383 7,886 9,418 10,979 12,569 14,187 15,832 17,504 19,203 20,928 HC Medium 138 5,237 6,468 7,722 8,999 10,299 11,618 12,954 14,309 15,685 17,080 Low 94 4,376 5,399 6,440 7,498 8,573 9,664 10,772 11,896 13,036 14,191 Boost 96 4,209 5,198 6,207 7,233 8,279 9,342 10,416 11,506 12,613 13,735 HC Medium 69 3,836 4,732 5,644 6,572 7,514 8,471 9,442 10,427 11,426 12,438 Low 52 3,331 4,109 4,900 5,703 6,519 7,346 8,186 9,038 9,902 10,775 Boost 60 2,518 3,110 3,714 4,329 4,956 5,593 6,241 6,899 7,569 8,246 HC Medium 42 2,133 2,635 3,147 3,668 4,199 4,739 5,288 5,846 6,413 6,985 Low 28 1,821 2,250 2,688 3,134 3,589 4,052 4,522 5,001 5,487 5,981 1 NOTE: Correction factor for 1.0 gpm, multiply by 0.87 **For output at water temperatures below 140 F, optional 107 F low temperature cut-off required. NOTE: For proper sizing, use the rating at Medium or Low speeds. FAN CONVECTOR 180 F WATER TEMP MODEL FAN SPEED BASEBOARD C.I. RADIATORS # (525 BTU/FT) (225 BTU/SQ FT) HC Boost/Med/Low 41/33/26 ft 95/77/61 sq ft HC Boost/Med/Low 33/27/23 ft 78/64/53 sq ft HC 9-6 Boost/Med/Low 22/20/17 ft 51/46/40 sq ft HC 6-4 Boost/Med/Low 13/11/10 ft 31/26/22 sq ft MODEL UNIT WEIGHT # WEIGHT PACKED HC HC HC HC MODEL FT WG # 0.5 GPM 1.25 GPM HC HC HC HC /2" Pipe Entry 1 7 / 8 " 5 1 /2" A Front View Cable Entry Bottom View 1 11 /16" 2 9 /16" 4 5 /8" 2 1 /16" /16" 3 3 /16" 9 7 /16" Side View Water Connections 6" NOTE: For surface mounting application only. DIMENSIONS MODEL # A HC " HC " HC " HC " COOLING MODE: ENTERING WATER/AIR TEMP. DIFF. ºF Model Flow Fan Latent* BTU/hr Sensible BTU/hr # Rate Speed 25ºF 35ºF 45ºF 25ºF 35ºF 45ºF HC gpm Boost 6,430 10,638 15,488 5,239 6,263 7,157 Medium 6,080 10,035 14,588 4,774 5,806 6,719 Low 5,466 8,995 13,042 4,333 5,163 5,886 HC gpm Boost 4,932 8,088 11,706 4,166 5,075 5,882 Medium 4,034 6,588 9,503 3,449 4,132 4,731 Low 3,359 5,485 7,853 2,934 3,608 4,211 HC gpm Boost 2,662 4,314 6,187 2,169 3,013 3,849 Medium 2,218 3,585 5,132 1,961 2,324 2,638 Low 1,822 2,939 4,204 1,626 1,943 2,218 HC gpm Boost 1,810 2,921 4,178 1,459 2, Medium 1,409 2,271 3,243 1,275 1,561 1,816 Low 1,147 1,845 2,633 1,047 1,300 1,527 *These figures are at 50% relative humidity. LO-LINE HC FAN CONVECTOR SPECIFICATIONS - Engineered to be efficient. Fan Unit... A highly efficient tangential fan extends the full width of the heat exchanger, giving extremely quiet, trouble-free operation. All units have aluminum fans, sealed motor bearings, and permanently lubricated porous bronze sleeve fan bearings. Controls... The Lo-Line Heater Cooler has a three speed fan, best controlled by a 110V AC heat/cool thermostat with 3-speed sub-base. (By others.) Heat Exchanger... Fin tube heat exchanger is a manifold design with copper water conduits expanded to create firm contact with the surrounding aluminum fins. Special air turbulator design maximizes the rate of heat transfer. All units are hydraulically tested to 300 psi. Tamper-Proof Controls Cover... All units include a tamper-proof controls cover which conceals all electrical controls from unauthorized usage. from zinc-coated painted steel. Water Connections and return are 1 /2" copper to compression isolation valves in the lower left corner of the unit. An air vent(s) for bleeding the convector is easily accessed through the front of the unit with a screwdriver. No special key is needed. Warranty offers a full ten year Myson, Inc
12 Slim-LineTM Fan Convector from MODEL FLOW RATE FAN SPEED AIR DELIVERY # GPM CFM SL Boost 186 Medium 127 Low 97 SL Boost 186 Medium 127 Low 97 Slim-Line Fan Convector SLIM-LINE FAN CONVECTOR BTU/HR HEAT OUTPUT ENTERING 65 F reserves the right to make changes or improvements to our products which may affect these specifications. NOTE: For proper sizing, use the rating at Medium or Low speeds. FAN CONVECTOR 180 F WATER TEMP MODEL FLOW RATE FAN SPEED BASEBOARD C.I. RADIATORS # GPM (525 BTU/FT) (225 BTU/SQ FT) SL Boost 22 ft 52 sq ft Medium 20 ft 46 sq ft Low 17 ft 40 sq ft SL Boost 29 ft 68 sq ft Medium 26 ft 60 sq ft Low 23 ft 53 sq ft ENTERING WATER TEMPERATURE ( F) 120* 130* ,663 6,657 7,661 8,664 9,668 10,572 11,678 12,680 13,684 14,687 4,881 5,887 6,745 7,651 8,559 9,567 10,374 11,281 12,186 13,096 4,207 5,018 5,829 6,639 7,450 8,261 9,072 9,883 10,694 11,504 7,404 8,719 10,034 11,349 12,663 13,978 15,293 16,608 17,923 19,237 6,457 7,646 8,831 10,023 11,411 12,399 13,588 14,776 16,280 17,153 5,510 6,572 7,634 8,696 9,758 10,820 11,882 12,944 14,005 15,068 *For output at these water temperatures, optional 107 F low temperature cut-off required. MODEL UNIT WEIGHT # WEIGHT PACKED SL FLOW RATE FT WG GPM " 3 /4" 6 11 /16" 15 9 /16" 31 7 /8" 3 1 /4" 6 7 /8" NOTE: For surface mounting application only. 1 7 /8" 1 3 /8" Side View 5" Centerlines of pipe entry Minimum space required (floor to bottom of Slim-Line) 2 5 /16" C L Centerline of pipe entry Front View Controls... Units have a three-speed Boost/Medium/Low fan switch and built-in thermostat. All models have low-limit thermostats which close at 129 F and reopen at 109 F (±7 F). SLIM-LINE FAN CONVECTOR SPECIFICATIONS Engineered to be efficient. from zinc-coated painted steel. Tamper-Proof Controls Cover... All units include a tamper-proof controls cover which conceals all electrical connections from unauthorized usage. 10 Myson, Inc Warranty... offers a full ten year
13 CSUTM Economical Fan Convector from MODEL FLOW RATE FAN SPEED AIR DELIVERY # GPM1 CFM CSU-10M 3.0 Boost 99 Normal 62 CSU-15M 3.0 Boost 91 Normal 66 CSU-23M 3.0 Boost 129 Normal 92 1 Note: Correction factor for 1.0 gpm, multiply by 0.87 reserves the right to make changes or improvements to our products which may affect these specifications. CSU FAN CONVECTOR BTU/HR HEAT OUTPUT ENTERING 65 F FAN CONVECTOR 180 F WATER TEMP MODEL FLOW RATE FAN SPEED BASEBOARD C.I. RADIATORS # GPM (525 BTU/FT) (225 BTU/SQ FT) CSU-10M 3.0 Boost/Normal 11/16 ft 27/38 sq ft CSU-15M 3.0 Boost/Normal 16/23 ft 37/53 sq ft CSU-23M 3.0 Boost/Normal 21/36 ft 48/85 sq ft ENTERING WATER TEMPERATURE ( F) 120** 130** ,437 3,226 4,173 5,195 6,040 6,852 7,763 8,659 9,500 10,341 1,190 1,954 2,529 3,165 3,823 4,481 5,319 5,973 6,609 7,245 1,928 3,886 4,994 6,102 7,203 8,715 10,331 11,947 14,000 15,053 1,524 2,484 3,452 4,418 5,385 6,352 7,317 8,282 9,240 10,198 4,400 6,481 8,573 10,665 12,750 14,838 16,947 19,027 21,000 23,235 2,018 3,461 4,687 5,751 6,983 8,260 9,518 10,813 12,262 13,771 **For output at these water temperatures, optional 107 low temperature cut-off required. NOTE: For proper sizing, use the rating at Normal speed. MODEL UNIT WEIGHT # WEIGHT PACKED CSU-10M CSU-15M CSU-23M MODEL FT WG # 1 GPM 3 GPM CSU-10M CSU-15M CSU-23M CSU Fan Convector DIMENSIONS A MODEL # A B CSU-10M " " CSU-15M " " Top View CSU-23M " " 4 23 /32" 1 1 /2" 3 3 /4" A B Air Out 6 1 /4" Back panel mounting holes 13 1 /4" 2 9 /16" Optional legs provided with unit Air In Wall Side Front View Side View Water connections 7 /8" conduit hole 3" 5 /8" NOTE: For surface or floor mounting application only. 9 /16" 1 9 /16" Bottom View 1 9 /16" Controls... Units have a two speed Boost/Normal fan switch and built-in thermostat. All models have low-limit thermostats which close at 129 F and open at 109 F (± 7 F). Optional low temperature thermostat is available. CSU FAN CONVECTOR SPECIFICATIONS Engineered to be efficient. from zinc coated steel with a baked epoxy polyester. Warranty... offers a full ten year Myson, Inc
14 Kickspace Fan Convector Installation 1. A kickspace heater must have a free flow of air through the unit. We have designed our grills to allow for sufficient airflow. The opening in the kickspace must allow unrestricted airflow. (See drawing below.) Looking at the grill, you should not be able to see any part of the kickboard. Failure to do so will cause the motor to overheat and void the warranty. 2. The kickspace heater needs to be sized appropriately for the job. For proper sizing, use the ratings at normal speed. If the unit needs to be in the boost or high setting to heat the room adequately, then the kickspace heater is too small. Running the unit in boost or high for extended periods of time will shorten the motor fan assembly life. If the heating unit is below the main or more than 4 1 /2 feet horizontally from the main, install two MonoFlo tees with the supply arrows facing each other. Keep and Tees 12" apart Water Flow Water Flow 12" Water Flow Mounting Screws Cut cabinet kick plate so make up air can get in. Cabinet Kick Plate Cool Air Intake Fan Motor Assembly Cool Air Intake Cut cabinet kick plate so make up air can get in. WH II 5000 rough opening is 18 3 /4" WH II 9000 rough opening is 22 3 /4" Cabinet Kick Plate Cool Air Intake Cool Air Intake ON/OFF Switch Hot Air EZ-Hose Kit The EZ-Hose Kit is designed specifically for use with the WH II 5000 and WH II 9000 Kickspace Heaters. While it may be used for other hydronic products, will not be responsible for compatibility. Components: 2-30" braided stainless steel hoses, 1 /2" compression x 1 /2" MPT 2 - Screwdriver slot ball valves, 1 /2" compression x 1 /2" FPT Assemble the male end of the hose to the female end of the ball valve using the recommended Loctite #565 thread sealant. Connect the compression end of the hoses to the stub-outs on the kickspace unit. Make sure that the return side hose is connected to the top stub-out so that air will be forced through the heat exchanger to where it can be removed at the air vent. Connect the compression ends of the ball valves to the appropriate supply and return pipes from the heating system. Copper Pipe Copper Pipe 12 Myson, Inc
15 and Fan Convector Installation Optional Piping Arrangements The following drawings are general examples. Consult a certified heating professional for your specific application. recommends TRV valves on all layouts except series loop system for maximum comfort and control of radiators. This does not apply to Fan Convectors. General information on the use of MonoFlo tees: Scoop type is installed on the supply Venturi type is installed on the return Boiler MonoFlo Tee Circulation Pump 12" Regular MonoFlo or Tee Venturi Tee Loop pipe size varies with load MonoFlo or One Pipe System Acceptable for all heating applications, balancing valves required. If heating unit is below the main or more than 4 1 /2 feet horizontally from the main, install two MonoFlo tees with the supply arrows facing each other Fan Convectors and Cast Iron s have different heating characteristics. Therefore, it is recommended that the Fan Convector be on a separate controlled heating zone. Circulation Pump Boiler Boiler Circulation Pump Circulation Pump Regular Tee 12" MonoFlo Tee Series Loop System Not compatible with fan convectors. Limited to 15K btuh on panel radiators. A single Fan Convector may be added using MonoFlo tees as shown. Two Pipe Reverse System Acceptable for all heating applications, balancing valves required when a Fan Convector is used with radiators. Radiant Manifold Circulation Pump Boiler Circulation Pump Regular Tee Boiler Two Pipe Direct System Acceptable for all heating applications, balancing valves required. Home Run System Myson, Inc
16 The Limited Warranty warrants the original purchaser that products manufactured and/or supplied by them will be free from defects in materials and workmanship under normal conditions of use, when properly installed and maintained in accordance with s instructions for a period of 36 months. During this warranty period, will, at its option, repair or replace any product, or part thereof, which shall be returned to the factory and determined by to be defective. THE PARTS WARRANTY: warrants replacement parts, when properly installed and maintained for a period of 120 days from the date of purchase. There are no warranties, expressed or implied, that extend beyond this warranty description. In no event will be liable for labor or consequential damages. HEATING PRODUCTS Myson, Inc. 948 Hercules Drive Colchester, VT Fax: M /2006
IMPORTANT: BEFORE INSTALLING ANY HEATING TERMINAL UNIT TO A DOMESTIC WATER HEATER, CONSULT THE LOCAL PLUMBING CODES.
QUIET-ONE Environmental Products 2000 Kickspace Heater Series Models: KS 2004, KS 2006 KS 2008, KS 2010 INSTALLATION OPERATING MAINTENANCE Please read these instructions thoroughly before beginning your
Select Radiators Installation Guide
Select Radiators Installation Guide Table of Contents Informational Symbols...3 Before You Begin...4 Select Rough-In... 5 Connection Installation...6 Optional Piping Arrangements...7 Conventional Wall
The space saving solution.
10 KICKSPACE KICKSPACE. Over 70% of people think that they would benefit from additional kitchen space (ICM Research 2012) Kitchen kindly supplied by Second Nature kitchens - www.sncollection.co.uk The
TABLE 1. Rugged cast aluminum alloy casing,celcon waterways with nichrome parts White (unless stainless steel housing)
CHRONOMITE INSTANT-FLOW MICRO WATER HEATER INSTALLATION AND OPERATION INSTRUCTIONS - (LOW FLOW MODELS) (Before installation, compare electrical needed for the model of heater selected) TABLE 1 Model No.
Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS
Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS Contents Page Ratings and Specifications..................... 2 Installation Requirements......................
INSTALLATION AND OPERATION INSTRUCTIONS - (LOW FLOW MODELS) (Before installation, compare electrical needed for the model of heater selected)
CHRONOMITE INSTANT-FLOW WATER HEATER INSTALLATION AND OPERATION INSTRUCTIONS - (LOW FLOW MODELS) (Before installation, compare electrical needed for the model of heater selected) TABLE 1 Model No. Wattage
Convection Ovens. BX Classic. Models BX4 / FG 189C, BX4-6040 / FG 158C, BX10 / FG 180C. Operator's Manual
Convection Ovens BX Classic Models BX4 / FG 189C, BX4-6040 / FG 158C, BX10 / FG 180C Operator's Manual Belshaw Bros., Inc. 814 44 th Street NW, Suite 103 Auburn, WA 98001 USA Phone: 206-322-5474 Fax: 206-322-5425
Low Profile Unit Cooler
Super-Flo Now available with EC Motors High Efficiency / High Reliability Low Profile Unit Cooler Publication No. 411.4 November, 2008 S A N I T A T I O N F O U N D A T I O N A L N A T I O N Air Defrost
Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW
Portable Air Conditioner OWNER S MANUAL Read these instructions before use 8 Model: MN12CES / MN10CESWW Voltage rating: 120V~60Hz Power rating : 1100W (MN12CES) Power rating : 900W (MN10CESWW) Customer
Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W
Portable Air Conditioner OWNER S MANUAL Read these instructions before use Model: MM14CCS Customer Support : 1-800-474-2147 Voltage rating: 115V~60Hz Power rating : 1400W For product inquiries or support
TANKLESS WATER HEATER INSTALLATION DIAGRAMS
TANKLESS WATER HEATER INSTALLATION DIAGRAMS Installation Diagrams Tankless Installation / Optional Return Small 10-15 Gallon Point-of-Use Water Single and Optional Return : One single, small capacity water
BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS
BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS PLEASE READ COMPLETE INSTRUCTIONS BEFORE YOU BEGIN LEAVE INSTALLATION INSTRUCTIONS AND USER'S GUIDE WITH OWNER ALL ELECTRIC WIRING AND PLUMBING MUST BE DONE
Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CHCSCS
Portable Air Conditioner OWNER S MANUAL Read these instructions before use Model: MM14CHCSCS Voltage rating: 120V~60Hz Power rating : 1400W(Cooling) Power rating : 1350W(Heating) Customer Support : 1-800-474-21477
REGULATORS 175/153 Series
175/153 Series 175 HEATING 153 COOLING Watson McDaniel reserves the right to change the designs and/or materials of its products without notice. 2002 Watson McDaniel Company Revised 7/2002 175 / 153 Screwed
ECOSTYLE RADIANT PANELS Installa on and Opera on Manual 2013
ECOSTYLE RADIANT PANELS Installa on and Opera on Manual 0 QUALITY 0 YEAR GUARANTEE Exclusively distributed by: Table of contents Panel radiators General / Guarantee Technical data and radiator dimensions
Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W
MODE ALARM Portable Air Conditioner OWNER S MANUAL Read these instructions before use 8 Model: MF08CESWW Voltage rating: 115V~60Hz Power rating : 800W Customer Support : 1-800-474-2147 For product inquiries
Cast Iron Radiator Heating Capacity Guide
Columbia Heating Products Company 1409 Rome Rd Baltimore, Maryland 21227 410-242-5300 Toll Free 800-645-7845 www.columbiaheating.com Use this handy guide to determine how much heat existing "old style"
M SERIES REFRIGERANT COIL MODULE REFRIGERANT COILS for R-22, R-407C, R-410A
Bulletin 20-20.2 / July 2012 M SERIES REFRIGERANT COIL MODULE REFRIGERANT COILS for R-22, R-407C, R-410A ➀ ➁ ➂ Model Number Key M 2430 C L 1 - A - ➀ Unit Type M=Modular Nominal Capacity 2430=24000 to 30000
Installation Instructions - For the following HEATER model numbers: 200, 300, 400, 500 Series Hydronic Heaters
Marine Heater Installation Instructions - For the following HEATER model numbers: 200, 300, 400, 500 Series Hydronic Heaters Approximate Installation Time: 3-5 Hours Tools Required: #2 Phillips Screw Driver;
WMSLW / WMBLWH Series Hydronic Upflow/Horizontal Left or Right, Heating and Cooling Air Handler
WMSLW / WMBLWH Series Hydronic Upflow/Horizontal Left or Right, Heating and Cooling Air Handler Installation Operation Maintenance The WMSLW/WMBLW series is designed for installation in a closet, utility
Light Duty Commercial Electric Water Heater
Features Heavy Duty Construction Hydrastone cement lining provides longer tank life Copper-silicon tappings cannot rust or corrode High impact composite jacket eliminates damage during installation and
OWNER S MANUAL FORCE 10 MARINE COMPANY 23080 HAMILTON ROAD RICHMOND, BC CANADA V6V 1C9 TEL: (604) 522-0233 FAX: (604) 522-9608
Electric Water Heater OWNER S MANUAL FORCE 10 MARINE COMPANY 23080 HAMILTON ROAD RICHMOND, BC CANADA V6V 1C9 TEL: (604) 522-0233 FAX: (604) 522-9608 If your water Heater is Damaged or you have questions
Glossary of Heating, Ventilation and Air Conditioning Terms
Glossary of Heating, Ventilation and Air Conditioning Terms Air Change: Unlike re-circulated air, this is the total air required to completely replace the air in a room or building. Air Conditioner: Equipment
VertiCool Space Saver 2 to 15 tons Water-Cooled and Chilled Water
2 to 15 tons Water-Cooled and Chilled Water Unique Solutions for Challenging HVAC Projects Your Choice for Limited Space Applications Water-Cooled Chilled Water The VertiCool Space Saver allows installation
Electric Flow Boiler
Electric Flow Boiler EHC offer the most comprehensive range of electric boilers in the market and with our wealth of knowledge and technical expertise we have designed the Slim Jim Electric Flow Boiler
TWIN-FLOIII HEATER INSPECT THE SHIPMENT IMMEDIATELY WHEN RECEIVED TO DETERMINE IF ANY DAMAGE HAS OCCURRED DURING SHIPMENT.
TFII-15 J17-63967 Beacon/Morris TWIN-FLOIII HEATER INSTALLATION INSTRUCTIONS TYPE K ATTENTION: READ THESE INSTRUCTIONS CAREFULLY BEFORE ATTEMPTING TO INSTALL, OPERATE, OR SERVICE THE BEACON MORRIS TWIN-FLO
Replacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS
Replacement parts DO NOT SERVICE THE BOILER WITHOUT A WM97+ MAINTENANCE KIT AVAILABLE Failure to adhere to these guidelines can result in severe personal injury, death or substantial property damage. The
MAC-120HE-01 Air-Cooled Chiller
MAC-120HE-01 Air-Cooled Chiller 10 Ton / 120,000 BTUH Air-Cooled Chiller 208/230-1-50/60 1 HVAC Guide Specifications Air-Cooled Liquid Chiller Nominal Size: 10 Tons Multiaqua Model Number: MAC-120HE-01
TECHNICAL GUIDE 95.5% SINGLE STAGE GAS-FIRED RESIDENTIAL MULTI-POSITION GAS FURNACES MODELS: TG9S DESCRIPTION FEATURES
TECHNICAL GUIDE 95.5% SINGLE STAGE GAS-FIRED RESIDENTIAL MULTI-POSITION GAS FURNACES MODELS: TG9S NATURAL GAS 40-130 MBH INPUT Due to continuous product improvement, specifications are subject to change
Gas Unit Heaters Duct Furnaces Horizontal - 60 HZ Form No. LF24-100-400 (10/2011) LF24 Standard
LF Standard Features Horizontal unit heaters are compact in design and easy to install. Steady State Efficiencies of up to 80.%. Ideal for economical commercial heating systems. Shipped completely assembled
High efficiency, cast-iron gas boiler
SENTRY High efficiency, cast-iron gas boiler LOWER PROFILE MAKES PROBLEM INSTALLATIONS EASY SENTRY High efficiency, cast-iron gas boiler A smarter choice for informed The boiler you choose for your home
Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling
Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling 250_P1 R10/7/2015 Copyright 2015 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice.
3Aftermarket Systems. Air Conditioners and Kombos.. 411. Heater/Pressurizer...440. System Matrix...441. Aftermarket System Requirements...
3Aftermarket Systems Air Conditioning & Heating Replacement Parts Aftermarket Systems Air Conditioners and Kombos.. 411 KA-300 Air Conditioner... 411 KK-315 Heater/Air Conditioner Kombo...412 KA-400 Air
Pump Specifications 405 Series Commercial Drain Pump (High-Temp) 2 Solids handling
Pump Specifications 405 Series Commercial Drain Pump (High-Temp) 2 Solids handling 405_P1 R1/27/2012 Copyright 2012 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice.
USER MANUAL WARNING! CONTENTS MODEL 1 SPECIFICATIONS READ ALL INSTRUCTIONS BEFORE PROCEEDING. Non-Programmable Single Stage Heat/Cool Thermostat
Builder MODEL 1010 Series Non-Programmable Single Stage Heat/Cool Thermostat USER MANUAL Compatible with low voltage single stage gas, oil or electric heating or cooling systems, including single stage
Explosion-Proof Electric Unit Heaters
Type FX4 FX4 Explosion-Proof Electric Air Heaters FX4 heaters are UL listed and/or CSA certified for use in hazardous locations. They are designed for dry indoor industrial applications such as oil refineries,
Overview of Baseboard Heating
Overview of Baseboard Heating If you live in an apartment equipped with a baseboard heating system, please take a moment to review the following sections so that you can better understand how your heating
Chilled Water Fan Coil Unit. Model:HFCA Size 03~14
Chilled Water Fan Coil Unit Model:HFCA Size 03~4 The Best Choice for Comfort =The Best Results Quiet Comfort Slope coil avoid air flow perpendicular impact Low noise permanent split capacitor motor Metal
PRODUCT PRODUCT CODE TECHNICAL INSTRUCTIONS PAGE
Table of Contents PRODUCT PRODUCT CODE TECHNICAL INSTRUCTIONS PAGE # Electric Room Comfort Controller NEW! RDY2000 Room Comfort Controller RDY 129-905 D-3 Electric for Specialized Applications Surface
Roof Top Air Conditioner INSTALLATION AND OPERATING INSTRUCTIONS
Roof Top Air Conditioner INSTALLATION AND OPERATING INSTRUCTIONS Ducted System RECORD THIS UNIT INFORMATION FOR FUTURE REFERENCE: Model Number: Serial Number: Date Purchased: This manual must be read and
KONRAD. Hybrid Fancoil Series
KONRAD Hybrid Fancoil Series Konrad is an innovative radiator which cools you down and warms you up. Indeed, it cools in summer and heats in winter; but it makes it with an incomparable quietness. Thanks
Pre-Fab Easy Installation For Models: 006-CT-USK, 008-CT-USK Installation and Operating Instructions for Existing Homes with Standard Piping
Instruction Sheet 102-140 Pre-Fab Easy Installation For Models: 006-CT-USK, 008-CT-USK Installation and Operating Instructions for Existing Homes with Standard Piping Plant I.D. 001-1024 EFFECTIVE: November
INSTALLATION INSTRUCTIONS GEO-BOOSTER TM
Table of Contents General Description 1 Parts list 1 Installation 2 New Ground Loop 2 Retrofit 4 Temporary 6 Troubleshooting 8 INSTALLATION INSTRUCTIONS GEO-BOOSTER TM General Description The Geo-Booster
NAVIEN AMERICA INC. 17855 FITCH AVENUE
Navien America Inc. Specification Details for the Navien models: CC-240 CC-240A For Potable Water Heating and Space Heating NAVIEN AMERICA INC. 17855 FITCH AVENUE IRVINE, CALIFORNIA, USA 92614 Toll Free:
Stainless Steel Single and Dual Circulation Kits
Instruction Sheet P/N 160780 01 Stainless Steel Single and Dual Circulation Kits Introduction The single and dual high-pressure circulation kits allow you to vary and control the circulation rate of coating
Domestic Hot Water Recirculation Systems Application, Selection & Installation Guide
Water Circulation Pumps & Circulators Domestic Hot Water Recirculation Systems Application, Selection & Installation Guide Taco Catalog # 100-41 Supersedes: 08/07/15 Effective Date: 09/01/15 Printed in
Residential/Commercial Gas Condensing High Efficiency Tankless Water Heaters
Residential/Commercial Gas Condensing High Efficiency Tankless Water Heaters FEATURES ULTRA-LOW NOx CONDENSING TECHNOLOGY PROVIDES UNPRECEDENTED 0.95 ENERGY FACTOR DURABLE HEAT EXCHANGER Primary Heat Exchanger
Seaward Products OWNER S MANUAL WATER HEATERS. Serial Number:
Seaward Products WATER HEATERS OWNER S MANUAL Serial Number: IMPORTANT SAFETY INSTRUCTIONS WARNING When using electrical appliances, basic safety precautions to reduce the risk of fire, electrical shock,
Foodservice Equipment Specialists P.O. Box 880 Saco, ME. / U.S.A. 04072 877-854-8006 * FAX (207) 283-8080
Foodservice Equipment Specialists P.O. Box 880 Saco, ME. / U.S.A. 04072 877-854-8006 * FAX (207) 283-8080 FOR SERVICE ASSISTANCE U.S. AND CANADA CALL: 1-877-854-8006 24 HOURS/DAY 7 DAYS/WEEK TABLE OF CONTENTS
ECOCIAT. Domestic hot water heat recovery unit
Heat recovery unit Domestic hot water High energy efficiency with R410A Compact and quiet Scroll compressors Brazed-plate heat exchangers Heating Heat recovery ENVIRONMENTALLY HFC R410A PROTECTION DE FRIENDLY
SPACE COOLERS. P.O. Box 956 Paoli, PA 19301 (800) 523-7590 FAX (610) 251-0805 www.coilcompany.com. The leader in packaged Space Cooling.
SPACE COOLERS P.O. Box 956 Paoli, PA 19301 (800) 523-7590 FAX (610) 251-0805 www.coilcompany.com The leader in packaged Space Cooling. 2 Table of Contents Description Space Cooler from Coil Company. A
CoolTop. A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60
CoolTop A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60 Application CoolTop is a new, unique air conditioning unit especially designed for datacenters.
LSA LSE, LSR & LST LPA LPE, LPG & LPH LAA LAE, LAG & LAH COMMERCIAL WALK-IN COOLERS AND FREEZERS
FOR COOLERS ABOVE +34ºF Low silhouette, draw through, high velocity units Capacity from 4,500 to 39,000 BTU/HR./10ºF TD LSA LSE, LSR & LST FOR COOLERS AND FREEZERS FROM -20ºF TO +34ºF Low silhouette, draw
E2 Series Electric Furnaces
E2 Series Electric Furnaces Service Manual Table of Contents Electrical Requirements... 10 Codes, Specifications Requirements... 10 Connection Supply Service Wires... 10 Furnace Sequence of Operation...
ALL WEATHER W-SERIES QUARTZ TUBE ELECTRIC INFRARED RADIANT HEATER INSTALLATION USE & CARE MANUAL
ALL WEATHER W-SERIES QUARTZ TUBE ELECTRIC INFRARED RADIANT HEATER TABLE OF CONTENTS: INSTALLATION USE & CARE MANUAL IMPORTANT INFORMATION Assembly Instructions 2 Wiring Instructions 2 Outdoor Installation
Installation & Maintenance Instructions
(400mm) 15-3/4" (35mm) 1-3/8" (95mm) 3-3/4" K Series (Model A) Fan Forced Wall Heaters (485mm) 19-1/8" (463mm) 18-1/4" FILE #E21609 Installation & Maintenance Instructions Dear Owner, Congratulations Thank
Filterfans. Air Flow data: PF 1000 PF 2000 PF 2500 PF 3000 PF 5000 PF 6000 PF 7000
Filterfans Patented Click & Fit design provides a hardware free installation! Poured-in foam gasket allows for quick NEMA 12 sealing against the enclosure (except PF 1000) Plastic made from strong (ABS-FR),
Your safety and the safety of others are very important.
NATURAL GAS TO PROPANE CONVERSION KIT 090 INSTALLATION INSTRUCTIONS FOR ALTITUDES 0 -,00 FT. ONLY PROPANE CONVERSION KIT SAFETY... INSTALLATION REQUIREMENTS... Tools and Parts... LP Gas Requirements...
DTM04 TANK MONITOR DTM08 TANK MONITOR Dtm12 TANK MONITOR. Installation and Operation Manual
DTM04 TANK MONITOR DTM08 TANK MONITOR Dtm12 TANK MONITOR Installation and Operation Manual 1 ENGLISH Safety Instructions 2 Features 2-3 Specifications 3 Installation 4-5 Wiring Diagrams 6-7 Warranty 8
PROAIR Water-Cooled Air Conditioner. CR43WC Model INSTRUCTION MANUAL. Rev. E 2013 Pentair Technical Products P/N 10-1008-167
PROAIR Water-Cooled Air Conditioner CR43WC Model INSTRUCTION MANUAL Rev. E 2013 Pentair Technical Products P/N 10-1008-167 87976466 TABLE OF CONTENTS HANDLING & TESTING THE AIR CONDITIONER...3 INSTALLATION
Water Pump Replacement
1 of 8 2/5/2008 6:36 AM Document ID# 713637 2001 Cadillac Seville Print Water Pump Replacement Tools Required 1. J 38816-A Water Pump Remover & Installer 2. J 38185 Hose Clamp Pliers
FOXAIR 60/50 ALL MODELS
FOXAIR 60/50 ALL MODELS OPERATION AND SERVICE MANUAL UNIT WEIGHT - ALL MODELS APPROX. 300 POUNDS FOXTRONICS, INC. 38 L x 28 W x 24 H Love Field-Dallas TX MADE IN THE USA 3448 West Mockingbird Lane Dallas,
Hot Water Boilers and Controls Why Condensing Boilers are Different. Presented Oct. 14, 2008 Long Island Chapter, ASHRAE
Hot Water Boilers and Controls Why Condensing Boilers are Different Presented Oct. 14, 2008 Long Island Chapter, ASHRAE H.W. Boilers and Controls Major types of boilers Advantages and disadvantages Resistance
Installation Manual CLIFC Fan & Coil Variable Speed
Installation Manual CLIFC Fan & Coil Variable Speed General Description GENERAL DESCRIPTION FANS EQUIPMENT Totally Factory assembled within the unit all piping, wiring, and required controls for operation
Cooktop Low-Profile Ventilation Hoods
INSTALLATION GUIDE Cooktop Low-Profile Ventilation Hoods Contents Wolf Cooktop Low-Profile Ventilation Hoods........ 3 Cooktop Low-Profile Hood Specifications.......... 4 Cooktop Low-Profile Hood Installation............
Boston, Venice, Kodiak. Enviro Wood Fireplace Inserts
Boston, Venice, Kodiak Enviro Wood Fireplace Inserts Why buy an Enviro Wood Insert? Up to 84.7% Efficiency - EPA approved and up to 84.7% efficiency - Enviro makes highly efficient wood inserts to help
STOVES & INSERTS PELLET. www.regency-fire.com PELLET STOVES & INSERTS. woo
PELLET www.regency-fire.com STOVES & INSERTS woo PELLET STOVES & INSERTS why choose Regency? Clean Burning Heating Solutions In 1979, I founded Regency Fireplace Products with a mission to produce the
Series GM. Peerless Boilers. Residential/Commercial Gas Boilers
Peerless Boilers Series GM Residential/Commercial Gas Boilers The Series GM cast iron, hot water boiler is ideal for use in large residences or commercial applications. This gas-fired, atmospheric boiler
SINGLE PACKAGE VERTICAL AIR CONDITIONERS
SINGLE PACKAGE VERTICAL AIR CONDITIONERS AIR CONDITIONERS l HEAT PUMPS l ELECTRIC HEAT QUIETER BY DESIGN SIMPLE TO INSTALL CONCEALED INSTALLATION www.friedrich.com VERT-I-PAK ideal for extended stay properties,
LOBOY 16 AIR CONDITIONERS
INSTRUCTION MANUAL FOR: LOBOY 16 AIR CONDITIONERS McLean Midwest Corp. dba: McLean Cooling Technology 11611 Business Park Blvd. N Champlin, MN 55316 Tel: 763-323-8200 Fax: 763-576-3200 www.mcleancoolingtech.com
Installation Manual. Features SMART SWITCH OCCUPANCY SENSOR. Maximum Energy savings
Features SMART SWITCH OCCUPANCY SENSOR Installation Manual Maximum Energy savings Sensitive 180º view passive infrared motion detector keeps lights on only when rooms are in use. No ON switch so lights
Centauri. Condensing Fire Tube Water Boiler 399 to 1000 MBH
Centauri Condensing Fire Tube Water Boiler 399 to 1000 MBH Pre-mix surface burner with up to a 7-to-1 turndown NOx levels as low a 5 ppm at full rate Operates on 4" gas pressure shown with optional gauges
Installation Instructions
Installation Instructions Built-In Dishwasher If you have questions, call 1-800-4-MY-HOME (1-800-469-4663) or visit our website at: www.sears.com BEFORE YOU BEGIN Read these instructions completely and
VC Series Zone Valves BALANCED 2-WAY AND 3-WAY HYDRONIC VALVES
VC Series Zone Valves BALANCED 2-WAY AND 3-WAY HYDRONIC VALVES PRODUCT DATA Design VC Series zone valves consist of: 2-way or 3-way valve housing available with various connection ends Spindle and cartridge
Mustang Series PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE. M115-2 (Globe) M1115-2 (Angle) Schematic. Standard Components
Schematic Throttles to reduce high upstream pressure to constant lower downstream pressure Throttles to maintain minimum upstream pressure PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE
Technical Data. Installation
Technical Services: Tel: (800) 81-91 / Fax: (800) 791-5500 Model 51 (1) Riser Manifold 1-1/ thru 6 Inch (DN40 thru DN150) For NFPA 1 Sprinkler Systems General Description The Figure 51 (1) Riser Manifolds
Condensing Boiler Efficiency
Condensing Boiler Efficiency Date: July 17, 2012 PRES E NT ED BY DO N L E O NA RDI LE O N A RD I I NC. HV AC T RAI N I N G & C ON SU LT IN G Concepts 1 The current state of evolution in boiler design 2
Electric Water Heater
Electric Water Heater Operation and Installation Manual (LIMITED WARRANTY AND TANK REPLACEMENT POLICY) The following information should be noted at time of installation and retained for future reference.
SECTION 23 81 43 HEAT PUMPS
SECTION 23 81 43 HEAT PUMPS PART 1 GENERAL 1.1 SUMMARY A. Section Includes: 1. Packaged rooftop heat pumps. 1.2 REFERENCES A. American Society of Heating, Refrigerating and Air-Conditioning Engineers:
Commercial Portable Air Conditioners
Commercial Portable Air Conditioners Air Rover commercial portable air conditioners provide the environmental stability and comfort required by today s sensitive equipment, allowing your business to avoid
Cooling Capacity CFM range @.5 in. w.c. (125 Pa)
N8MXL Product Specifications 80% ECM Single Stage Heating Furnace EASIER TO SELL 80% AFUE Flame roll out sensors standard Category I venting Blocked vent switch 24 VAC humidifier terminal Electronic air
OVEN PARTS For Models:GSC308PJB05, GSC308PJQ05, GSC308PJT05, GSC308PJS05 (Black) (White) (Biscuit) (Black Stainless)
OVEN PARTS 30" BUILT IN ELECTRIC COMBO SENSOR/SC (GOLD LINE) 3 05 Litho In U.S.A. (cre) 1 Part No. Rev.A OVEN PARTS 1 Literature Parts 4455994 Installation Instructions Use & Care Guide 8300346 Microwave
ELECTRONIC THERMOSTAT AND THERMOMETER With SPEED CONTROL
148 OLD CONCORD TURNPIKE, BARRINGTON NH 03825 USA TEL (603) 868-5720 FAX (603) 868-1040 1-800-435-6708 E-Mail:[email protected] www.seafrost.com ELECTRONIC THERMOSTAT AND THERMOMETER With SPEED CONTROL
Powers Controls TH 192 HC Heating/Cooling Room Thermostat
Powers Controls TH 192 HC Heating/Cooling Room Thermostat Technical Instructions Document No. 155-066P25 TH 192-2 50 60 70 80 70 TH0356R1 60 80 POWERS Description The TH 192 HC thermostats are proportional
Water Fired Chiller/Chiller-Heater. WFC-S Series: 10, 20 and 30 RT Cooling
Water Fired Chiller/Chiller-Heater WFC-S Series: 1, 2 and 3 RT Cooling W E A R E F R I E N D L Y T O T H E E A R T H Water Fired SINGLE-EFFECT Chiller or Chiller-Heater Absorption Principle Cooling Cycle
SunMaxx Solar Filling Station Operating Instructions
SunMaxx Solar Filling Operating Instructions Content 1. Declaration of conformity... 2 2. Introduction... 2 3. Transportation and unpacking... 4 4. Mounting and commissioning... 5 5. End of operation...
BASYS INSTALLATION INSTRUCTIONS FOR ELECTRONIC CAPACITANCE SENSING LAVATORY FAUCETS EFX-3XX Pedestal, Sensor Activated Lavatory Faucets
BASYS INSTALLATION INSTRUCTIONS FOR ELECTRONIC CAPACITANCE SENSING LAVATORY FAUCETS EFX-3XX Pedestal, Sensor Activated Lavatory Faucets Any Application. Any Environment. Code No: 0816407 Rev. 4 (07/12)
hore PRODUCT CATALOGUE nd Offsh arine an ms for Ma & Refrig AUTONOMOUS AIR CONDITIONERS HV VAC &
hore nd Offsh arine an ms for Ma geration System & Refrig HV VAC & PRODUCT CATALOGUE AUTONOMOUS AIR CONDITIONERS O ! "# $ % & " ' (! ) * +,+( -../01..2 PRODUCT CATALOGUE 72-17 AUTONOMOUS AIR CONDITIONERS
Commercial Semi-Instantaneous Water Heaters
FEATURES HWI Models A. O. Smith s HWI models are available for operation with steam or boiler water as the energy source. They are factory assembled with components sized, piped and checked at the factory
1. Geo Vertical 2. Geo Horizontal
1 2 1. Geo Vertical 2. Geo Horizontal 1 2 3 1. Geo Vertical 2. Geo Vertical with towel rail 3. Geo Vertical with cover plate Geo Vertical 47 Geo Vertical Dimensions Connections Range GEVW_Geo Vertical
PIPES AND TUBES FOR HVAC PIPING AND EQUIPMENT
PIPES AND TUBES FOR HVAC PIPING AND EQUIPMENT GENERAL INFORMATION 1.1 This section applies to piping systems for chilled water, hot water, condenser water, steam, condensate return, fuel oil, refrigerant
300 Series PA Pump and Cooler Assemblies
Type 300 Series PA Sizes 300 thru 370 (Page 1 of 9) 300 Series PA Pump and Cooler Assemblies Pump and Cooler Assemblies with Air/Oil Heat Exchanger When compact gear drives require assistance to dissipate
Commercial Gas Furnace Upflow
Commercial Gas Furnace Upflow Model G24-200 80% A.F.U.E. 200,000 Btuh Input Heating Cap. 7.5 or 10 Tons Nominal Add-On Cooling GUK FEATURES Certified by A.G.A./C.G.A. Laboratories. Heavy gauge painted
Nest Learning Thermostat Installation Guide. Installation step-by-step
Nest Learning Thermostat Installation Guide Installation step-by-step Contents Compatibility. 3 In the box. 4 Before you start. 5 Choose an installation method. 6 Replacing an existing wired thermostat.
Local Dealer: www.cebrands.com
Local Dealer: C.E. LLC - Miami, FL USA www.cebrands.com Res2012-Rev2 QUALITY YOU CAN FEEL Residential Product Line >TCA7,9 Tempstar SmartComfort TXT + Air Conditioner Featuring The Observer Communication
IMPORTANT SAFETY INSTRUCTIONS WARNING READ AND SAVE THESE OPERATING AND SAFETY INSTRUCTIONS BEFORE USING THIS HEATER.
THERMAWAVE CERAMIC HEATER Model HZ-850 Series Model HZ-860 Series IMPORTANT SAFETY INSTRUCTIONS WARNING READ AND SAVE THESE OPERATING AND SAFETY INSTRUCTIONS BEFORE USING THIS HEATER. Warning Failure to
36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve
Operator: Save these instructions for future use! FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE PERSONAL INJURY AND/OR PROPERTY DAMAGE. DESCRIPTION
Name of Equipment Silver King Model SKMCD1P/C1. This equipment chapter is to be inserted in the appropriate section of the Equipment Manual.
Name of Equipment Silver King Model SKMCD1P/C1 This equipment chapter is to be inserted in the appropriate section of the Equipment Manual. Manufactured exclusively for McDonald s By Silver King Refrigeration,
Chilled Water Fan Coil Unit
Chilled Water Fan Unit Model: HFCF02~HFCF14 Airflow Range: 200~2400m 3 /h Features and Benefits The Best Choice for Comfort The Best Results - Quiet Comfort Low noise permanent split capacitor motor. Metal
PRESSURE REDUCING CONTROL VALVE
Schematics Throttles to reduce high upstream pressure to constant lower downstream pressure Low Flow By-Pass controls at low flows 4 PRESSURE REDUCING CONTROL VALVE with LOW FLOW BY-PASS FEATURE Main Line