IEC 61439-1 & 2 standard. The reference for safe and reliable LV switchboards



Similar documents
P System Cubicles. Certified for more safety

IEC >>> IEC GUIDE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

More than just OK. Okken: Low voltage switchboard for electrical distribution and motor control

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & Instructions For Installation, Operation & Maintenance

know-how Giant in distributing electricity for industry Prisma GK

Securing your electrical installations Prisma,

IEC specifications for LV assembly switchboards

Unified requirements for systems with voltages above 1 kv up to 15 kv

FAQs-Main switchboard design criteria

The easy way to build switchgear and controlgear assemblies in compliance with the regulations

Type-Tested Power Distribution Board 8PT with Rear Busbars. sivacon

Low voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application.

LV MCC LOW VOLTAGE SWITCHGEAR MOTOR CONTROL CENTRE PRODUCT GUIDE

The Intelligent AX1 Switchgear for Medium Voltage

12 SOLAR PHOTOVOLTAIC POWER SUPPLY SYSTEMS by John Ware. PV modules are current-limiting

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV

SURGE PROTECTIVE DEVICES

Coordination and protection of busbar distribution

Siemens AG Power Transmission and Distribution Medium Voltage Division Mozartstr. 31c Erlangen Germany.

Application Switchgear for industrial and commercial applications. U e V AC 230/ (per pole)

METAL-CLAD AND METAL-ENCLOSED SWITCHGEAR 3.6KV~40.5KV. tgood.com. Energy. Fast.

SIVACON The Versatile Low-Voltage Switchboard

2 The installation system

The power distribution board that sets new standards

SAFETY ALERT SWITCHBOARD INTERNAL SEGREGATION AND IP RATING. May 2014 BACKGROUND

Comparative study for cables and busbars

Technicaldata General

ALTERNATIVE METHODS FOR INTERNAL ARC TESTS ON 12 KV AND 24 KV METAL-ENCLOSED SWITCHGEARS WITH COMPACT RMU

HIGH VOLTAGE SHORE CONNECTION

ELEKTROTEHNI KO PODJETJE Leskoπkova cesta 12, 1000 Ljubljana, SLOVENIA

Changing industry standards: friend or foe?

R.C.C.B. s two-pole LEXIC

Submit shop drawings for equipment provided under this section Shop drawings shall indicate:

SIVACON Low Voltage Switchboard

Technical Application Papers No.11 Guidelines to the construction of a low-voltage assembly complying with the Standards IEC Part 1 and Part 2

Gain energy insight and control with PowerLogic. PowerLogic EGX300 integrated gateway-server

Andre Gretler, LPLS BU Function Operation and Sales Low Voltage Systems ANSI vs IEC. BU 3101 Low Voltage Systems June 27, 2013 Slide 1

Nothing s BetterThan the Original MODAN Power Distribution Systems

Modular Systems wind portfolio overview Power Collection and Grid Connection products

Electrical Shore Connections / Cold Ironing

NATUS NES / NES-H Draw-out Type Medium Voltage Switchgear Systems. Safe energy distribution that meets the highest industrial requirements

NEW RANGE OF CABINETS DRIVIATM. Innovation at your service. THE GLOBAL SPECIALIST in electrical and digital building infrastructures

An Alternative Approach to Improving SAIDI and SAIFI Indicators

High-Voltage Compact Switchgear 3AP1 DTC for 145 kv and 245 kv

High-Voltage Circuit-Breakers 3AP1/ kv up to 550 kv. Power Transmission and Distribution

New SACE Emax 2 for UL 1066 From Circuit Breaker to Power Manager

Eaton Safety & Reliability Solutions in the Oil & Gas Industry Electrical

COMPARISON OF ANSI/IEEE AND IEC REQUIREMENTS FOR LOW- VOLTAGE SWITCHGEAR

Easily connect your switchboards to facility management solutions

What are the basic electrical safety issues and remedies in solar photovoltaic installations?

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

Standard-compliant switchgear and controlgear production

SUGGESTED SPECIFICATION for Series 185 Service Entrance Rated Automatic Transfer Switches

Functional system Prisma P

Low Voltage Switchboards The Best Technical Solution for Your Ship

Modular Systems, PPMV, 2014 UniPack-G Glass Fiber Reinforced Polyester Compact Secondary Substation

Power transformers. Generator step-up and system intertie power transformers Securing high-quality AC transmission

Secondary Unit Substations

Guide to the electrical parameter classifications of IEC and IEC safety standards

Guidance for upgrading to GB (IEC : 2005, MOD)

Dielectric Withstand Testing in a Production Environment

CHECKING AND TESTING ELECTRICAL INSTALLING WORK

Power Voltage Transformers for Air Insulated Substations. THE PROVEN POWER.

Secure your electrical network. PACiS The Safety Solution for Healthcare Institutions

White Paper SolarEdge Three Phase Inverter System Design and the National Electrical Code. June 2015 Revision 1.5

National Craft Assessment and Certification Program S P E C I F I C A T I O N S

Automation Products. Low Voltage Switchgear MNS System Overview

Permissible ambient temperature Operation Storage, transport

DEVICES OF PROTECTION AND COMMAND

NZECP 14: 1995 ISSN COVER PAGE

Industrial Process Plants. Residential & Commercial Buildings. Roads & Tunnels. Airports & Seaports

Insulation resistance

e 2 ALPHA Medium Voltage Switchgear Data Sheet K EN

Choosing for tranquility

employed to ensure the continuing reliability of critical systems.

Product overview brochure. ABB Medium Voltage Products Our one-stop approach for every medium voltage application

Power factor correction and harmonic filtering. Rectimat 2 Automatic capacitor banks. Catalogue. Building a New Electric World

Paper on Basbar Trunking System for Electrical Supply to Industrial & commercial Installation

High Voltage Circuit Breakers 3AP Type 72.5 kv to 800 kv Answers for energy.

Hyperlinks are Inactive

METER REQUIREMENTS GENERAL REQUIREMENTS SECTION D

Union County Public Schools. Facilities Department. Electrical. Safe Work Practices

Explosion proof enclosures

ELECTRICAL INSPECTION BULLETIN (Effective )

White paper. ABB solutions for switching and protection of low speed wind turbines

Switchgear and Metal-Enclosed Bus

ST Series POWER SUPPLIES USER INSTRUCTIONS

MV vacuum circuit breaker Evolis. When trust guides your steps

Sample - No Commercial Use

HAZARDS, INCLUDING SHOCK, ARC FLASH AND FIRE

Advantages of Fixed Circuit Breaker Switchgear

AUTOMATIC TRANSFER SWITCH. Changeover Type from 250A to 2500A

Installation and safety instructions for AC/DC built-in devices

13. Electrical network design methodology and application example

Power transformers. Special transformers Railway

UNIVERSITY OF WASHINGTON Facilities Services Design Guide. Electrical. Metering and Monitoring. Basis of Design

What will MV switchgear look like in the future? by Jean-Marc Biasse

(PREVIEW) Indian Standard COMMON SPECIFICATION FOR HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR STANDARDS

DOMESTIC ELECTRICAL INSTALLATION CERTIFICATE (Requirements for Electrical Installations BS 7671 IEE Wiring Regulations)

Transcription:

IEC 61439-1 & 2 standard The reference for safe and reliable LV switchboards

IEC61439-1 & 2 The power of a standard adapted to your needs IEC standards are today legal or market references. The new IEC 61439-1 & 2 is the reference for the construction of electrical LV switchboards. IEC 61439 fully satisfies the requirements of designers and users of new generation LV switchboards: safety of persons and equipment, electrical availability, long-term reliability and conformity. To guarantee these essential values, the standard sets a wide range of requirements. These include designing a system compliant in all aspects, checking interactions and consistency between switchgear and equipment, providing protection against electrical, mechanical and structural hazards, and simplifying system maintenance and upgrading cycles. Schneider Electric/IEC Standard: a long success story Ever since the construction of its first electrical switchboard, has never ceased its commitment to Assembly Manufacturers to guarantee fully compliant systems, and so much more. has always considered that conformity of its solutions to IEC standards was a minimum, a springboard allowing it to go further still in its offer to users. And indeed, in its role as Original Manufacturer, constantly proves on an everyday basis that it does so. 30 years experience in the construction of tested switchboards (and the associated standards). 100% of switchboard architectures are tested and conform to IEC standards. Full support For panel-builders and contractors 3 million tested LV electrical distribution switchboards in operation world-wide. 2

Original Manufacturer and Assembly Manufacturer: Both involved in tested assemblies Standard IEC 61439 clearly defines the type of verifications that must be conducted by both organisations involved in final conformity of the solution: the Original Manufacturer, guaranteeing assembly system design and the Assembly Manufacturer, responsible for the final conformity of the switchboard. Project specification* Specifier > Specifies the needs and constraints for design, installation, operation and upgrading of the complete system. > Checks that its requirements have been fully integrated by the Assembly Manufacturer. Depending on the application, the specifier could be the end-user or a design office. Original Manufacturer The organisation that has carried out the original design and the associated verification of an assembly system. He is responsible for the "Design verifications" listed by IEC 61439-2 including many electrical tests. Assembly System Assembly Manufacturer (Panel builder) The organisation (whether or not the same as the OM) responsible for the completed assembly. He is responsible for "Routine verifications" on each panel produced, according to the standard. If he derivates from the instructions of the original manufacturer he has to carry out again design verifications. Tested Assembly End-User Should ask for a certified LV switchboard. By systematically requesting routine verifications, he ensures that the assembly system used is compliant. * has developed a specification guide. 3

The main 10 functions of All the verifications proposed by standard IEC 61439 safety, continuity of service and compliance with end - Safety Voltage stress withstand capability Insulation to withstand long-term voltages, transient and temporary overvoltages guaranteed through clearances, creepage distances and solid insulation. > Measurement of clearances and creepage distances > Power frequency dielectric test > Impulse withstand voltage test, when clearances are greater than specified values > Visual inspection of clearances (subject to design conditions and creepage distances) > Power frequency dielectric test Current-carrying capability Protect against burns by limiting > Temperature rise tests > Visual inspection excessive temperatures: > Or comparison with a tested reference design, > when any single circuit is continuously under restrictive conditions > Random verification of tightness loaded to its rated current and > Or, under very restrictive conditions, calculations > when any circuit is continuously loaded to with safety margins (including 20% derating of its rated current multiplied by its rated devices) diversity factor. Short-circuit withstand capability Withstand short-circuit thanks to short-circuit protection devices, short-circuit coordination, and capability to withstand the stresses resulting from short-circuit currents in all conductors. > Short-circuit tests (Icc and Icw) of the main circuit, including the neutral conductor, and of the protection circuit > Or comparison with a tested reference design under restrictive conditions > Visual inspection Protection against electric shock Hazardous live parts are not accessible (basic insulation protection) and accessible > IP XXB test and verification of insulating materials > Mechanical operation tests > Visual inspection of basic and fault protection conductive parts are not hazardous for life > Verification of dielectric properties > Random verification of (fault protection, and continuity of protective > Measurement of the resistance between each tightness of the protective equipotential bonding). exposed conductive part and the PE terminal circuit connections > Short-circuit strength of the protection circuit Protection against fire or explosion hazard Protect persons against the fire hazard: > Glow wire test None resistance to internal glowing faulty elements, > Special test according to IEC TR 61641, through selection of materials and various where specified design provisions. 4

standard IEC 61439 contribute to the achievement of 3 basic goals: user requirements Continuity of service Maintenance and modification capability Capability to preserve continuity of supply without impairing > IP tests safety during Assembly maintenance or modification. Through basic and fault protection and optional removable parts. > Mechanical operation tests (especially for removable parts) > Effectiveness of mechanical actuating elements > Check protection of persons against electric shocks Electro-Magnetic Compatibility Properly function and avoid generation of EMC disturbances through incorporation of electronic devices complying with the relevant EMC standard, and their correct installation. > EMC tests according to product standards or generic EMC standards None Compliance with end-user requirements Capability to operate the electrical installation Properly function, according to: > By inspection > Visual inspection > The The electrical diagram and the specifications (voltages, co-ordination, etc.) by selecting, installing and wiring the appropriate switching devices. > The specified operating facilities (Access to Man-Machine Interfaces, etc.) through accessibility and identification. Capability to be installed on site > Impulse withstand voltage test of isolating distance for optional withdrawable units > Effectiveness of mechanical actuating elements and function test (where relevant) Withstand handling, transport, storage and installation constraints, > By inspection > Number, type and and be capable to be erected and connected through selection or > Lifting test, taken from identification of terminals design of the enclosure and the external terminals, and by means IEC 62208 for external conductors of provisions and documentation. Protection of the Assembly against environmental conditions Protect the Assembly against mechanical and atmospheric conditions through selection of materials and various design provisions. > IP test > IK test > Corrosion test > UV test (outdoor only) None 5

IEC 61439 and From small tertiary to large industrial sites, requirements but also improving significantly safety, operating Small tertiary / buildings Offers Product inside* Safety Linergy busbar Providers optimum performance in Icw withstand (1s short circuit) with a third of the wieght of equivalent rating Copper busbar. Front access to all phase connections enables direct and safer maintenance approach. Some 3 times lighter than a standard copper busbar for equivalent short-circuit performances. Acti9 circuit-breakers Guarantee total safety during maintenance and absolute protection against electric shocks, provide zero-risk lockdown, protect loads, etc. Functional units and panel components Guarantee electrical continuity of Prisma Plus switchboards thanks to scribe system. Continuity of service Compact NSX circuit-breakers Total discrimination, remote indication of motor overloads and actuation of a contact switch (SDTAM module), direct access to maintenance indicators, etc. Polypact row splitter blocks For practical and reliable device rows: total insulation, reliable connection without maintenance. Distribloc centralised splitter blocks Modular quick-connection monobloc splitter blocks Compliance with end-user requirements Specifier guide A reference support designed by to guarantee fully compliant specifications (end-users) and assemblies (Assembly Manufacturer). Fastening grids Attached to front plates, door hinges and panels, they guarantee electrical continuity at the 1st assembly ¼ turn. * Using only devices guaranties the complience with IEC as well as the reliability of installations. 6

solutions: 100% compatible! designed a plenty of solutions answering to IEC61439-1 & 2 availibility and cost control...for a long time." inside* Large industrial sites Offers Product Safety Locking of live parts High level of safety and protection, preventing all on-load operations: IP20 shields, connections protected by a plug-in outlet, access possible to switchgear only after opening the circuit-breaker and withdrawing the drawers, status indicators to prevent risk of error, etc. Thermal monitoring Thermal monitoring of temperature rises using probes installed at the heart of the sensitive areas (e.g. busbars, drawer contacts), thus reducing the likelihood of failure and shortening maintenance times. PolyFast system The PolyFast partitioned terminals guarantee perfect insulation of connection against electric shocks. A exclusivity! Continuity of service Tesys U motor feeder Modular concept offering excellent open-endedness, without uncabling the power base. Functional units replaced or added easily, without need for tools. 3 in 1 systems are available: simple, open-ended and compact. Modularity of functional switchboards Can be modified or upgraded easily. Free spaces are provided for "last minute" addition of motor feeders or new functions. Masterpact circuit-breakers Designed to automatically monitor and manage the energy sources of the LV distribution network, thus guaranteeing installation reliability. Compliance with end-user requirements Specifier guide A reference support designed by to guarantee fully compliant specifications (end-users) and assemblies (Assembly Manufacturer). Withdrawable drawers All switchboard upgrades are possible with power on, without interruption of service and completely safely. 3 positions: connected, test and disconnected. Switchboard configurations and settings are made on the front face. Withstand to harsh environments Excellent mechanical strength for installations in seismic areas and for sensitive applications. Various degrees of protection (IP30, IP41 or IP54) for installations in corrosive atmospheres (e.g. cement works, iron and steel, etc.). 7

Few upgrades for enhanced safety and durability IEC 61439-1 & -2* = Only "Tested assemblies" General Rules IEC 61439-1 Power SC Ass. Distribution Boards Construction Sites Public networks Busbar Trunking IEC 61439-2 IEC 61439-3 IEC 61439-4 IEC 61439-5 IEC 61439-6 * IEC 61439-1 & -2 are published since January 2009, and IEC 61439-3 to -6 should be published in 2011. IEC 60439-1 = "Type Tested" & "partially Type Tested" General Rules + Type Tested Assemblies / Partially TTA old IEC 60439-1 Distribution Boards Construction Sites Cable Distrib. Cab. Busbar Trunking IEC 60439-3 IEC 60439-4 IEC 60439-5 IEC 60439-2 Overview of the main verification changes (IEC 61439 vs IEC 60439) > Design verification Increased requirements for insulating materials and transient overvoltages withstand tests. Temperature rise verification: Verification by test of each functional unit loaded alone with its rated current Clear methods for the selection of representative samples of an Assembly system to be tested Test done in 4 steps: individual functional units, main and distribution busbars, and complete Assembly Heating resistors only allowed to simulate circuits adjacent to a circuit under test Possible verification by comparison with a tested design under strict conditions, including derating Exemption of test (calculation) only allowed up to 1600 A instead of 3150 A under strict conditions, including a 20% derating. Possible short-cricuit withstand verification by comparison with a tested design under strict condition 200 operating cycles instead of 50 for locking, interlocking and withdrawable parts Lifting test (from IEC 62208) Corrosion resistance test for metallic parts (from IEC 62208). > Routine verification More detailed list of the verifications More severe requirements for clearances Industries SAS As standards, specifications and designs change from time to time, please ask for confirmation 35, rue Joseph Monier of the information given in this publication. CS 30323 F- 92506 Rueil Malmaison Cedex Printed on ecological paper RCS Nanterre 954 503 439 Capital social 896 313 776 www.schneider-electric.com Publication: Industries SAS Layout: SEDOC Printing: ART838060 2010 - - All rights reserved. DESWED101028EN 11-2010