Aliseo Anesthesia system



Similar documents
Boaray 700 Anesthesia Machine

Understanding Anesthetic Delivery Systems Dean Knoll, CVT, VTS (Anes.) Anesthesia Technician Supervisor University of Wisconsin Madison, WI May 2003

Anesthesia Solutions. Prima SP2 Anesthesia Systems. The Future of Anesthesia. Partnership for Life

OMNI TOUCH SCREEN PATIENT MONITOR

Operator s Instruction Manual

Aespire View. User s Reference Manual. Software Revision 6.X

S/5 Anesthesia Monitor. The clinician s choice

Fabius GS. Inhalation Anesthesia Machine Software 3.n Operating Instructions. Because you care

The centrepiece of a complete anaesthesia workstation

Impact Uni-Vent 754 Portable Ventilator

Your personal anesthesia assistant DRÄGER PRIMUS

GE Healthcare. Avance Carestation. Innovating with you, shaping exceptional care

Sensors / Modules / Monitors. Breath Gas Sensing and Monitoring. For life supporting systems in intensive, emergency and ambulant care

Datex-Ohmeda Critical Care Monitor

Aestiva Anesthesia Machine. Technical Reference Manual

DATA SHEET. Capnography option. November 2013 V2.2

GE Healthcare. Aespire Essential performance Compact design

Online Infrared Flue Gas Analyzer Gasboard 3000

Aespire User s Reference Manual Part 2. Setup, Cleaning and Sterilization, Maintenance and Troubleshooting

Oxylog 3000 plus Emergency & Transport Ventilation

Impact Uni-Vent 750 Portable Ventilator

Scope: Applies to the various anesthesia vaporizers used to deliver a known concentration of vaporized liquid. Sample. Type Interval Time Required

«The compact and mobile testing device for ventilators.»

Datex Ohmeda. Centiva /5. Service Manual Software rev. 2.1n

For over 40 years, the leader in. nitrous oxide. equipment technology.

IFC 070 Technical Datasheet

Instruction Manual. T3111 T3111L T3111P T3111Ex

2/ These vacuum switches are used in measuring ranges between -1 and 0 bar.

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

For every breath he takes. Trilogy200 ventilator s added sensitivity lets you breathe easier knowing your patients are where they belong home.

The Anesthesia Ventilator

MEDICAL SYSTEMS. Monnal T60. Touch and Breathe.

Experiment HE-6: Breath by Breath Measurement of Respiratory Exchange Ratio (RER)

T Substation Maintenance and Commissioning Test Equipment

Oxygenation and Oxygen Therapy Michael Billow, D.O.

T0118 T2118 T3118. Instruction Manual

SpO2 PULSE OXYMETER MD-300

Instruction Manual Dräger MSI ALV

VENTILATION SERVO-s EASY AND RELIABLE PATIENT CARE

RRV934. Multi-controller. Synco living

SHARKY 775 COMPACT ENERGY METER ULTRASONIC

The Anesthesia Ventilator

Veterinary Clinics and Hospitals

ServoCare PRODUCTS AND ACCESSORIES CATALOG ISSUED OCTOBER 2004 CRITICAL CARE

Description TERMINAL UNIT AFNOR NF S

MP-4000 Alarm List (Software version or later)

Prima SP2 Anaesthetic Machine Range. Service Manual. Partnership for Life

Artificial Ventilation Theory into practice

Digital pressure gauge for industrial applications Model DG-10-S, Standard version Model DG-10-E, Enhanced version

A/C refrigerant system, overview

Vroom Hardware manual ver Code 114VROOHWE00. Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR

MEDUMAT Easy CPR The Guiding Emergency Ventilator

Laerdal Patient Monitor Help Page 1 June 14, 2012, Rev E

INNOC. Innocare-T. Innomed. Innomed s intensive and anesthesiological monitor system can be used both as a transport or bed-side care unit

Typical Aluminum GFM Mass Flow Meter

DM70 Hand-Held Dewpoint Meter for Spot-Checking Applications

2000 Respironics, Inc. All rights reserved.

DEBSON TM2 OXYGEN THERAPY FLOWMETERS WITH PRE ADJUSTED FLOWRATES MORE SAFETY GAS FLOW BETWEEN TWO POSITION. English version 11/ 2 010

Vista 120 Patient Monitor

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

Fully Automated Distillation of Petroleum Products including Biofuels OptiDist - the Optimal Solution

TMS TANK MANAGEMENT SYSTEM

Principles of the Anesthetic Machine

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

SALES SPECIFICATION. SC7640 Auto/Manual High Resolution Sputter Coater

ACE. Automated Soil CO 2 Exchange System. Soil flux: an important component of total carbon budget

SHARKY 775 COMPACT ENERGY METER ULTRASONIC

HIGH PRESSURE TECHNOLOGY HYDRAULICS PNEUMATICS TESTING EQUIPMENT

ADU 5. Automatic Distillation Unit

REGSON TM2 OXYGEN-THERAPY PRESSURE REGULATORS WITH FLOWMETER WITH PRE-ADJUSTED FLOWRATES MORE SAFETY GAS FLOW BETWEEN TWO POSITION

ECOCIAT. Domestic hot water heat recovery unit

FLIGHT MEDICAL INNOVATIONS LTD. FLIGHT 60 Ventilator. Operator's Manual

T U R B I N E G A S M E T E R

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Waveguide Access Point WGA631. Product Guide

Digital input modules

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

Medical Air Systems: Scroll

ECMO AND LIFE SUPPORT SYSTEMS QUADROX PLS AND ROTAFLOW HARDWARE AND ACCESSORIES

Centro-Matic Automatic Lubrication Systems System Controls

DC Electronic Loads 8500 series

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

You can also call our customer service department at (Press 3) Monday Friday, 8:30am-6:00pm EST.

DiwiTherm, Resistance Thermometers Model TR75, with digital Display Battery or Solar Powered

Agilent N8973A, N8974A, N8975A NFA Series Noise Figure Analyzers. Data Sheet

Ventilators/Transport*

FLR 1000 & 1000-BR Series Flow Sensors & Meters For Gases

Common Ventilator Management Issues

E4E PILOT OPERATED DIRECTIONAL CONTROL VALVE WITH ELECTRIC PROPORTIONAL CONTROL SERIES 51

How To Use A Flowmeter

GREISINGER electronic GmbH

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

The first desktop system for easy and accurate Cardio Pulmonary Exercise Testing. VO 2 max and sub-max V0 2

FLIGHT MEDICAL INNOVATIONS LTD. FLIGHT 50 Ventilator. Service Manual. DOC-0004 Rev B. Sep 2012

Bedside Monitor BSM-9101K

Pressure transmitter For general industrial applications Model A-10

Porter Instrument Division

Proportional pressure regulators VPPE

Digital inductive conductivity transmitter

Transcription:

Aliseo Anesthesia system Cost effective technology in anesthesia Features Ventilator Electrically driven Volume controlled, ACV, electronic PEEP Ventilation with ambient air Stand-by mode at end case Direct manual ventilation capability Integrated monitoring Ventilatory monitoring (Aliseo Basic) Ventilatory & Haemodynamic monitoring (Aliseo Haemo) ECG, NIBP, Temp, SpO2 Ventilatory & Respiratory gas analysis (Aliseo Full-Gas) CO2, O2, N2O, AA with automatic identification, MAC & Balance Gas mixer Aliseo Anesthesia System 3 gases with 5 flowmeter tubes mixer Holder for 2 vaporizers Independent mixed fresh gas outlet System management 10.4" LCD color display Flat panel keyboard Easy and intuitive controls Innovative patient circuit Integrated flow sensors Selectable Open or Circle circuit ventilation Fully autoclavable and "latex-free" Simple disassembly without tools Active/passive or Venturi scavenging system integrated in the patient circuit block

Physical specifications Complete system dimensions Trolley base Pendant base 160 cm 96 cm 70 cm 70 cm 78 cm 68 cm Typical weight: 95 Kg 90 Kg Upper shelf and holder for S/5 AM (optional) Shelf Holder - 16,4 cm 33,5 cm 32 cm 31,2cm 25 cm Weight limit: 25 kg 20 kg Anesthetic gas mixer Typical weight: Lung ventilator Typical weight: Table top Drawer 34 cm 49 cm 30 cm 20 Kg (without vaporizers) 26 cm 56 cm 52 cm 30 Kg 37 x 31 cm 25 cm 49 cm 30 cm * Shelves include fixing system to the monitors Ceiling mount Typical weight: 96 cm 70 cm 68 cm 37 Kg * Compatible with Soxil and Ondal ceiling columns Video display Type: Resolution: Displaying: * Depending on configuration Gas Mixer specifications 10.4" LCD color VGA (640 x 480 pixel) Up to three waveforms*, 10 hours graphical and numerical trends* Side rails Standard DIN: 10 x 25 mm Fresh gas outlet Standard connector: 22 mm OD, 15 mm ID, ISO Wheels Diameter: Brakes: Cylinder holders Optional cylinders: Positioning: Upper shelf (optional) Weight limit: 125 mm Single lever on frontal wheels Up to 2: O2 and N2O holder for two cylinders with fixing belts CC II - S/5 CM - CC5 - Light 32,7 cm 26 cm 20 kg Gas supply Medical gases: O2, N2O and Air Pipeline input range: min 350 kpa - max 500 kpa (± 20%) Gauges: Pipeline connections: Aux. outlet (optional): Inlet safety valve: O2 flush: O2 supply failure alarm: O2, N2O and Air (0-600kPa, ± 4% f.s.) NIST type. Connection for O2, N2O and Air with filter and inlet check valve O2 and Air Opening pressure 600-650 kpa 40 l/min Auditory alarm. Minimum alarm time: 8 seconds.

Flowmeters Range O2: Range N2O: Range Air: Gas mixture selection: Fresh gas relief valve: Hypoxic guard system Method: Minimal O2 concentration and N2O cut-off Anesthetic agents delivery Holder: Vaporizers: Ventilator specifications Ventilation modes Two flowmeter tubes - from 0.1 to1 l/min and from 1 to 10 l/min Two flowmeter tubes - from 0.1 to1 l/min and from 1 to 10 l/min One flowmeter tube - from 0.2 to 15 l/min ±10% (O2 and N2O) ±10% (Air from 0.6 to 15 l/min) ±15% (Air from 0.2 to 0.4 l/min) O2 and Air or O2 and N2O Opening pressure 90 hpa Electrically powered automatic ventilator Volume controlled ventilation AUTO (CMV) Assisted ventilation ACV Man/Spont Ventilatory performances Tidal volume: Steps: Minute volume: N2O flow control by mechanical link with O2 flow regulation and by O2 pressure 25% O2 in O2/N 2O mixture. Complete N2O shut-off during O2 missing Holder for 2 vaporizers with Selectatec coupling Datex-Ohmeda TEC 4, TEC5 and TEC 6 or vaporizers having compatible Interlock system from 50 to 1600 ml (Volume controlled mode) 50-300 (10 ml steps) 300-1000 (25 ml steps) 1000-1600 (50 ml steps) Max 20 l/min I:E ratio: 1:4, 1:3, 1:2, 1:1, 2:1, 3:1, 4:1 Peak gas flow: Respiratory rate: Plateau: Sigh: Inspiratory flow shapes: ACV trigger level: ACV inspiratory time: PEEP (electronic): Working pressure: 75 l/min from 6 to 60 breaths/min OFF, 10% of the breathing cycle OFF, 1/50, 1/100, 1/150 breaths, 1.5 x TV Constant, decreasing, increasing, sinusoidal from -2 to -14hPa below PEEP from 1 to 3 seconds OFF (0 hpa), from 3 to12 hpa from 3 to 70 hpa Delivering accuracy Tidal volume delivered: ±10% Respiratory rate: ±3% I:E ratio ±5% PEEP: ±2 hpa Ventilatory monitoring Flow-volume detection: Expiratory volume measurements: ±8% Airways pressure : Pressure measurements: 2 hot wire flow sensors (one on the expiratory line, the other one on the fresh gas inlet line) Bar graph indication for Tidal volume Digital indication for minute volume Tidal volume from 0 to 3000 ml Minute volume from 0 to 30 l/min Front panel gauge indication. 2 pressure transducers (one on the inspiratory line and one on the expiratory line). Numerical indication of Peak and Mean pressure; Airways pressure waveform display Gauge from -10 to +100 hpa Pressure transducers from -5 to 70 hpa Gauge ±2.5%. Pressure transducers ±1.5% Respiratory rate detection: ±3% O2 Concentration * : Sampling rate * : Fi O2 value * : Electronically detected by flow and airways pressure signals. Numerical indication. from 3 to 90 breaths per minute Galvanic cell O2 sensor 180 ml/min Bar graph and numerical value Range * : from 10 to 110% Accuracy * : ±2% Sensor lifetime * : Aliseo Basic and Haemo Ventilatory alarms Maximum airways pressure limit: Minimum airways pressure limit: Apnea: Tidal volume limits: Minute volume limits: Minimum 6 months, maximum 12 months from 15 to 70 hpa from 3 to 15 hpa (automatically added to the PEEP) Lasting more than 16 seconds without crossing the Paw min alarm level. Automatically set at -20% and +20% of the set value in AUTO and ACV mode. Not active in MAN-SPONT mode Automatically set at -20% and +20% of the set value in AUTO. The minimum limit is automatically set at 20% in ACV mode. The maximum limit can be set from +50% to +100% by steps of 10% Not active in MAN-SPONT mode

Respiratory rate limits: FiO 2 limits*: * Aliseo Basic and Haemo Automatically set at -10% and +10% of the set value in AUTO mode. The minimum limit is automatically set at 10% in ACV mode. The maximum limit can be set from +30% to +100% by steps of 10% between 21 and 90% the lower limit; between 50 and 100% the higher limit Haemodynamic specifications (Aliseo Haemo only) ECG Leads: Filter: Resolution: Protection from the interference of the electrosurgical apparatus: Heart beat indication: Cable: Waveform: Waveform speed: SpO2 I, II, III 0.5 30 Hz from 30 to 250 bpm ± 5% or 5 bpm 1 bpm Yes Adjustable sound beat every QRS detection Three leads patient cable ECG or SpO2 selectable real time waveform 12.5 or 25 mm/s IEC Class I, type CF from 40 to 100% Resolution: 80 100% ±2 digits; 50 80% ±3 digits 40 50% unspecified 1 bpm Display averaging time: Beat-to-Beat; Normal (10 s); Slow (20 s) Waveform: Pulse curve scaling: NIBP Modes: Numeric display: Measurement intervals: Max. inflation pressure: Venous clamp: ECG or SpO2 selectable real time waveform 2, 5, 10, 20, 50, AUTO IEC Class I, type BF adult from 25 to 280 mmhg pediatric from 25 to 200 mmhg AUTO MANUAL Systolic, diastolic, mean 3, 5, 15, 30, 60 min 150, 200, 280 mmhg ON OFF IEC Class I, type BF Temperature from 10 C to 45 C Resolution: 0.1 C Alarms Alarm indication: HR max: HR min: ±0.1 C (25-45 C); ±0.2 C (10-25 C) IEC Class I, type CF Asystolia, Leads off, SpO2 probe disconnection from monitor and patient, Cuff loose, Cuff occluded, from 35 to 250 bpm from 30 to 245 bpm SpO2 min: from 50 to 100% NIBP sys max: NIBP sys min: NIBP dia max: NIBP dia min: OFF to 265 mmhg OFF to 260 mmhg OFF to 265 mmhg OFF to 260 mmhg TEMP min: from 10 to 40 C Gas module specifications (Aliseo Full-Gas only) Respiratory monitoring Gas module: Gas detected: Measurement methods: Sensor: Compact module, M-CAiO CO2, O2, N2O, Anesthetic Agents with automatic identification Side-stream analyzer Sampling rate: 200 ml/min ±20% Data display: Paramagnetic chamber for O2; infrared analyzer for CO2, N2O and Anesthetic Agents Numerical Fi and Et values of all gases MAC and Balance, real time waveforms display for CO2, O2 and AA. CO2 measuring range: from 0 to 15 vol% (0 15 kpa, 0 113 mmhg) ±1 vol% O2 measuring range: from 0 to 100% ±0.2 vol% N2O measuring range: from 0 to 100% AA measuring range: Identification threshold: MAC range: Respiratory rate: ±2 vol% from 0 to 6 vol% (Halothane, Enflurane and Isoflurane); from 0 to 8 vol% (Sevoflurane); from 0 to 20 vol% (Desflurane) ±0.2 vol% 0.15 vol% from 0 to 9.9 MAC from 4 to 60 breaths/min (1% CO2 deviation in Standby mode)

Gas monitoring alarms Alarm indication: CO2 alarm limits: O2 alarm limits AA alarm limits Resp. rate alarm limits General specifications gas module Weight: Operating temp: Atmospheric pressure: Humidity: Apnea (after 20 sec in standby mode), Replace D-Fend, Fi N2O max, sampling line occlusion, sampling gas exhaust outlet occlusion from 0 to 114 mmhg ETCO2; OFF from 0 to 22 mmhg FiCO2 OFF from 18 to 100 % FiO 2; OFF from 10 to 100 % ETO 2 OFF from 0 to 30 % ETAA; OFF from 0 to 30 % FiAA2 OFF from 4 to 60 breaths/min (Standby mode) 122 mm 75 mm 228 mm 1.6 Kg Electrical specifications Power supply Power input: Power consumption: Grounding: Fuses: Communication port Serial interface: Function: from +10 to +40 C from 660 to 1060 mbar (500-800 mmhg) from 10 to 95% (non condensing) IEC Class 1, type BF 230 Vac, (± 10%), 50/60 Hz 80 W Hospital grade T 1.6 H 250V IEC Class 1, type B 2 connectors male 9 pin Environmental specifications Connection to external printer and UPS Classification The Datex-Ohmeda Aliseo is classified as a Class IIb device, in accordance with EU Medical Device Directive 93/42 Operational modes Breathing circuit: Selectable open and circle circuit with integrated AGS System. Direct ventilation by to and from system with APL valve. Carbon dioxide absorbent canisters Single use canister: Length: Weight: Volume Soda lime: Reusable Canister: Length: Weight: Volume: Ports and connectors Expiratory line inlet: Inspiratory line outlet: Expiratory line exhaust: Fresh gas excess exhaust: Fresh gas inlet: Materials D-O Compact Absorber Single Use 108 mm 147 mm 90 mm net 550 g / tare 90 g Canister 850 ml; Max. soda lime 600 ml Sofnolime; granule size 2.5 5 mm; moisture content 12 19%; color indicator: white to violet D-O Compact Canister Reusable 108 mm 147 mm 90 mm net 550 g / tare 90 g Canister 900 ml; Max. soda lime 700 ml 22 mm OD, 15 mm, ID ISO 22 mm OD, 15 mm, ID ISO 30 mm OD, 22 mm, ID ISO 30 mm OD, ISO 22 mm OD, 15 mm, ID ISO All materials in contact with exhaled patient gases are autoclavable, except gas sample line and disposable airway adapter. All materials in contact with patient gas are latex free System operation Operating temp: Humidity: Atmospheric pressure: Storage temperature: Safety standards from +10 to +40 C from 10 to 85% (non condensing) from 660 to 1060 mbar from 10 to +60 C Electrical: EN 60601.1 Electromagnetic compatibility (EMC): EN 60601.1.2 Anesthesia workstation: EN 740 Breathing circuit parameters Compliance: Inspiratory limb resistance: Expiratory limb resistance: Fresh gas excess valve resistance: 1.2 ml/cmh 2O (with patient tubes 1.5 m length 5.5 hpa @ 60 l/min 5.8 hpa (open); 8.3 hpa (circle) @ 60 l/min 0.75 hpa @ 5 l/min,1.5 hpa @ 10 l/min, 6 hpa @ 30 l/min

Anesthetic gas scavenging Overpressure valve: Sub-ambient valve: Scavenging indicator: Passive system: Active scavenging with pipeline aspiration: Active scavenging ejector (Venturi): Connectors: 2 hpa @ 30 l/min, 4.7 hpa @ 75 l/min 0.3 hpa @ 15 l/min 4 liters reservoir bag Up to 6 meters long and minimum 22 mm ID disposal tube. Adjustable extracted flow: max 30 l/min Adjustable extracted flow with ejector: 30 l/min max. Driving gas air or oxygen Passive/Venturi: 30 mm OD, male, ISO and standard hose nipple for compressed gas. Central pipeline aspiration: nipple for 12 mm diam. hose Datex-Ohmeda Division Instrumentarium Corp. P.O. Box 900, FIN-00031 Datex-Ohmeda, Finland Tel. +358 9 39411 Fax +358 9 146 3310 www.datex-ohmeda.com Datex-Ohmeda S.p.A. Via Cassanese, 100, 20090 - Segrate (MI) - Italy Tel. +39 02216931 Fax +390226926226 www.it.datex-ohmeda.com Code 023S02 Subject to change without notice