1 Oxylog 3000 plus Emergency & Transport Ventilation Offering high ventilation performance with features such as AutoFlow integrated capnography and non-invasive Ventilation, the compact and robust Oxylog 3000 plus helps you transport your patients safely and provides feedback on correctness of intubation and ventilation effectiveness. The Oxylog 3000 plus gives you confidence to master even the most demanding situations. MT
2 02 Oxylog 3000 plus Benefits High confidence during transport Whether you are transporting critically ill patients in your hospital or in the field, with new features such as AutoFlow, integrated capnography, full paediatric support and enhanced data connectivity, you don't have to compromise on therapy during transport. Wide range of ventilation modes and AutoFlow The Oxylog 3000 plus offers a complete range of volume- and pressure controlled ventilation modes, including VC-CMV, VC-AC, VC-SIMV, Spn-CPAP and PC-BIPAP*. Non-invasive ventilation with sophisticated leak compensation and pressure support is also provided as standard. With the AutoFlow option, you can provide volume controlled ventilation with minimised peak inspiratory pressure for advanced patient care. Integrated capnography Monitoring patients in the field can be challenging. Available with integrated mainstream CO 2 monitoring, the Oxylog 3000 plus helps you confirm correct intubation and ventilation performance at all times. Ready for paediatric patients A specially designed, dedicated paediatric patient circuit with reduced dead space and low compliance is available for use with the Oxylog 3000 plus. This enables you to provide quality ventilation to an even wider range of patients with a single device. Automatic altitude compensation (BTPS) Tested for use in fixed and rotary wing aircraft, the Oxylog 3000 plus automatically compensates for altitude, adjusting provided- and measured patient volumes accordingly, eliminating the need for manual calculation and reducing the risk of error. Dräger user interface and family platform The Oxylog 3000 plus uses the same intuitive user interface common to most current Dräger products. The select-adjust-confirm operating system facilitates a rapid user familiarization process. Many accessories can be shared between Oxylog systems. This increases your efficiency and saves you valuable storage space and training time. Advanced data export functionality With its advanced data export functions, the Oxylog 3000 plus can not only export ventilation parameter data to external monitors and data management systems in real time, but it can also take full advantage of Dräger
3 Oxylog 3000 plus 03 Benefits Remote Service. This innovative concept lets you transfer status information from your Oxylog 3000 plus to DrägerService for analysis. This supports you in increasing equipment up-time. * Trademark used under license Accessories Oxylog Trolley With the easy-to use functional Oxylog trolley system intensive care patients can quickly and smoothly be transported throughout the hospital without interrupting therapy. D D Allround wallholder (for use with Carrying System) Order-no
4 04 Oxylog 3000 plus Accessories Alduk IV Order-no (configuration) D D Automatic Oxygen Switch Order-no (configuration) Carrying System This ergonomically designed Carrying System provides an integrated solution for carrying and transporting an Oxylog 3000 plus or an Oxylog 2000 plus and an oxygen cylinder with a minimum of effort. The frame is small and light with rounded corners to prevent any discomfort in carrying. MT
5 Oxylog 3000 plus 05 Related Products Oxylog 1000 The Oxylog has been the natural choice of emergency care ventilator for more than 25 years. The Oxylog 1000 is the most compact ventilator in the Oxylog range. MT MT Oxylog 2000 plus Step up your performance with Oxylog 2000 plus. The Oxylog 2000 plus supports you in your daily challenge of saving peoples lives, no matter where the call takes you. Invasive or non-invasive, Oxylog 2000 plus can meet this challenge by putting essential ventilation tools at your fingertips. The Oxylog 2000 plus can make all the difference.
6 06 Oxylog 3000 plus Technical Data The Oxylog 3000 plus is a time-cycled, volume-controlled and pressure-controlled emergency and transport ventilator for patients requiring mandatory or assisted ventilation with a tidal volume from 50 ml upwards. Dimensions (W x H x D) Weight 290 x 184 x 175 mm (without handle and protection bracket) Approximately 5.8 kg (including internal battery) Gas supply Supply gas Gas supply O2 service pressure Gas consumption for internal control Medical Oxygen From a pipeline system or from an O2 cylinder 270 kpa to 600 kpa at 100 L/min Average 0.5 L/min Operating data Ventilation Modes VC-CMV, VC-AC, VC-SIMV, SpnCPAP, PC-BIPAP Additional settings for ventilation Pressure support: in the ventilation modes VCSIMV, PC-BIPAP* and SpnCPAP Apnoea ventilation: in the ventilation mode SpnCPAP AutoFlow (optional): in the ventilation modes VC-CMV, VC-AC and VC-SIMV NIV: in the ventilation modes: SpnCPAP (/PS), PC-BIPAP (/PS), VC-CMV /AF, VC-AC /AF and VC-SIMV/AF Special procedures Inspiration hold O2 inhalation (optional), with an inhalation mask 100% O2 Options Integrated mainstream CO2 measurement** CPR-behavior Ventilation Respiratory Rate Tidal volume VT Ti / I:E Real time data export via RS232, MEDIBUS protocol** AutoFlow : volume targeted - pressure controlled ventilation** Pressure-limited, non-constant-volume ventilation during inspiration time when Pmax is reached 2 to 60/min (VC-SIMV, PC-BIPAP) 5 to 60/min (VC-CMV, VC-AC) 12 to 60/min for apnoea ventilation 0.05 to 2.0 L; BTPS**** Ventilation time ratio I:E 1:100 to 50:1 Inspiration time Ti Inspiratory pressure Pinsp O2 concentration PEEP / CPAP Trigger sensitivity (flow trigger) Pressure support ΔPsupp Slope (pressure rise time) Max. inspiratory flow Displayed measured values Display type Curve display Patient hose types I:E or Ti configurable, for all ventilation modes 0.2 to 10 s PEEP +3 to +55 mbar 40 to 100 Vol.%**** 0 to 20 mbar 1 to 15 L/min 0 to 35 mbar (relative to PEEP) Slow, standard, fast 100 supply pressures > 350 kpa / 51 PSI; 80 supply pressures < 350 kpa / 51 PSI; 39 supply pressures <270 kpa / 39 PSI MVe, FiO2, RR, VTe, PEEP, Pmean, PIP, Pplat, MVesp, RRspon, etco2. Technology Electro-luminescence (EL) Pixels 240 x 128 Visible area 108 x 56 mm Airway pressure Paw curve, flow curve, CO2 curve (optional) Reusable adult hose (1,5 m / 3 m), Disposable adult hose (1,5 m / 3 m),
7 Oxylog 3000 plus 07 Technical Data Power supply Oxylog 3000 plus input voltage Disposable pediatric hose (1,9 m) 24 V ±6 VDC Input voltage AC/DC power pack 100 to 240 V~ / 50 to 60 Hz / 0.9 to 0.4 A~ Input voltage DC/DC converter Battery type Operating time (fully charged, typical ventilation), without CO2 sensor, reduced display brightness Operation time (fully charged, typical ventilation) Battery charging time Main alarms 12 / 24 / 28 VDC; 5 A / 2.5 A / 2.1 A Lithium ion battery Approximately 9.5 hours Approximately 7.5 hours Approximately 4 hours Airway pressure (Paw) high Adjustable from 20 to 60 Airway pressure (Paw) low Apnea back-up ventilation Leakage High Respiratory Rate etco2 high/low MVe high/low Incorrect patient hose Supply pressure low Operating Conditions Temperature range Temperature range for CO2 sensor Atmospheric pressure Relative humidity Electromagnetic compatibility (EMC) When pressure difference between Insp. and Exp. < 5 mbar or when the set pressure level is not reached When respiratory activity is no longer detected, adjustable time from 15 to 60 s VTe. is approx. 60% lower than VTi (not applicable in NIV) Patient breathes at a high spontaneous rate When the alarm limits for end-expiratory CO2 concentration have been exceeded. When the alarm limits for expiratory minute volume have been exceeded. Ventilator detects if incorrect patient hose type is connected Supply pressure < 270 kpa -20 to +50 C for basic device +10 to +40 C 570 to 1,200 hpa for basic device 5 to 95 % (no condensation) In accordance with IEC/EN :2007, EN and ISO Airworthiness In accordance with RTCA DO-160F, sections 7, 8, 16.6, , 17, 19.31, 20, 21, 25 Mechanical strength In accordance with MIL STD 810F, method Classification according to MDD 93/42/EEC Class IIb UMDNS-Code * Trademark used under License ** Options can be purchased during the initial ordering process or as future upgrades. *** BTPS: Body Temperature, Pressure, Saturated. Measured values referred to the conditions of the patient's lungs, body temperature 37 C / 99 F, airway pressure, water-vapour-saturated gas. **** Indirect measurement of O2 concentration (calculated from two measured flows).
8 08 Oxylog 3000 plus Notes Communications & Sales Marketing PP LE Chlorine-free environmentally compatible Subject to modifications 2016 Drägerwerk AG & Co. KGaA CORPORATE HEADQUARTERS Drägerwerk AG & Co. KGaA Moislinger Allee Lübeck, Germany Manufacturer: Drägerwerk AG & Co. KGaA Moislinger Allee Lübeck, Germany REGION EUROPE CENTRAL AND EUROPE NORTH Drägerwerk AG & Co. KGaA Moislinger Allee Lübeck, Germany Tel Fax [email protected] REGION EUROPE SOUTH Dräger Médical S.A.S. Parc de Haute Technologie d'antony 2 25, rue Georges Besse Antony Cedex, France Tel Fax [email protected] REGION MIDDLE EAST, AFRICA Drägerwerk AG & Co. KGaA Branch Office P.O. Box Dubai, United Arab Emirates Tel Fax [email protected] REGION ASIA / PACIFIC Draeger Medical South East Asia Pte Ltd. 25 International Business Park #04-27/29 German Centre Singapore , Singapore Tel Fax [email protected] REGION NORTH AMERICA Draeger Medical, Inc Quarry Road Telford, PA , USA Tel Toll-free Fax [email protected] REGION CENTRAL AND SOUTH AMERICA Dräger Panama Comercial S. de R.L. Complejo Business Park, V tower, 10th floor Panama City Tel Fax [email protected] Locate your Regional Sales Representative at:
Dräger Evita Infinity V500 ventilator ICU Ventilation and Respiratory Monitoring
Dräger Evita Infinity V500 ventilator ICU Ventilation and Respiratory Monitoring Combine fully-featured, high-performance ventilation with Infinity Acute Care System integration to meet the challenges
Your personal anesthesia assistant DRÄGER PRIMUS
D-16232-2009 Your personal anesthesia assistant DRÄGER PRIMUS 02 DRÄGER PRIMUS An entire world of care You re playing a vital role in an increasingly complex healthcare system. Your job is to provide state-of-the-art
Dräger Babylog VN500 Neonatal Open Care
Dräger Babylog VN500 Neonatal Open Care For generations to come. The Babylog VN500 combines our years of experience with the latest technology. The result is a complete, integrated ventilation solution
AutoFlow The Oxylog 3000 plus incorporates the benefits of pressure controlled ventilation into volume controlled ventilation
D-9125-2009 AutoFlow The Oxylog 3000 plus incorporates the benefits of pressure controlled ventilation into volume controlled ventilation Foreword Dear reader, Performing mechanical ventilation during
Polaris 5xx/7xx Medical Lights and Video
Polaris 5xx/7xx Medical Lights and Video Without light, surgery just isn t possible. Sufficient light is one of the fundamental requirements for the operating theatre. The Polaris lights were designed
Sekusept Cleaner Liquid Cleaning Agent Cleaning, Desinfecting and Drying
Sekusept Cleaner Liquid Cleaning Agent Cleaning, Desinfecting and Drying Concentrated liquid cleaning agent for manual cleaning of respiratory masks, respiratory protection equipment, diving apparatus
D-1188-2009. Move life-critical patient data on your existing network INFINITY ONENET
D-1188-2009 Move life-critical patient data on your existing network INFINITY ONENET 02 One Network rather than two MT-1351-2007 Patient monitoring data is life-critical. That s why hospitals have traditionally
Moving beyond telemetry INFINITY M300
D-19757-2009 Moving beyond telemetry INFINITY M300 02 MT-4187-2006 MT-4488-2006 D-19730-2009 03 Transforming telemetry into patient-worn monitoring From the standpoint of patient monitoring, today s busy
D-19673-2015. A cost effective monitor that meets your clinical needs VISTA 120
D-19673-2015 A cost effective monitor that meets your clinical needs VISTA 120 02 VISTA 120 03 Part of a complete departmental solution A comprehensive monitor at exceptional value D-3533-2011 Hospitals
Dräger PSS 3000 Self Contained Breathing Apparatus
Dräger PSS 3000 Self Contained Breathing Apparatus The Dräger PSS 3000 is a new generation of high performing breathing apparatus for firefighters. Combining comfort with exceptional pneumatic performance,
Vista 120 Central Monitoring System
Vista 120 Central Monitoring System Today, hospitals seek to improve their quality of care and work as efficiently as possible. The easy-to-use Vista 120 Central Monitoring System lets you centrally monitor
D-370-2010. Non-Invasive Ventilation (NIV) with the Oxylog 2000 plus and Oxylog 3000 plus
D-370-2010 Non-Invasive Ventilation (NIV) with the Oxylog 2000 plus and Oxylog 3000 plus 02 NON INVASIVE VENTILATION WARNING This booklet is not a substitute for the Instructions for Use of the Oxylog
Carina Pocket Guide Software version 3.n. The Carina Pocket Guide is not a replacement or substitute for the Instructions for Use.
MT-0569-2008 Carina Pocket Guide Software version 3.n The Carina Pocket Guide is not a replacement or substitute for the Instructions for Use. Any use of the device requires full understanding and strict
Dräger X-dock Release Notes Software-Update 01.07.00 and Manager Software 1.7.0
Supported operating system (X-dock Manager) Windows 7 Windows 8 Windows Server 2008 R2 Windows Server 2012 R2 Supported firmware versions (X-dock Manager) X-am 2000: > = v6.0 X-am 2500/5x00: > = v6.6 Pac
MEDICAL SYSTEMS. Monnal T60. Touch and Breathe. www.airliquidemedicalsystems.com
MEDICAL SYSTEMS Monnal T60 Touch and Breathe www.airliquidemedicalsystems.com Close to the emergency Monnal T60 has been designed for mobile medical intervention in all intensive care environments, both
Dräger Alcotest 9510 Evidential Alcohol Measuring Device
Dräger Alcotest 9510 Evidential Alcohol Measuring Device The Dräger Alcotest 9510 is an advanced breath alcohol measuring instrument for evidential applications. It is designed to comply with national
Agila Ceiling Supply Unit Medical Supply Units
Agila Ceiling Supply Unit Medical Supply Units Featuring a wide range of configurations and options to choose from, the compact and highly ergonomic Dräger Agila family uses a minimum of precious care
The Anesthesia Ventilator
The Anesthesia Ventilator Why is the piston replacing the bellows? For many decades, and millions of anesthetics, the bellows anesthesia ventilator has been a safe and effective clinical device. Indeed,
Movita Ceiling Supply Unit Medical Supply Units
Movita Ceiling Supply Unit Medical Supply Units Featuring a wide range of configurations and options to choose from, the versatile Dräger Movita family gives you enhanced loading capacity together with
Dräger Globe-Trotter GT5400 Neonatal Transport
Dräger Globe-Trotter GT5400 Neonatal Transport The Globe-Trotter GT5400 is the result of Dräger s ongoing commitment to developing a safer and more stable neonatal transport system. This system meets global
DATA SHEET. Capnography option. www.airliquidemedicalsystems.com. November 2013 V2.2
November 2013 V2.2 DATA SHEET www.airliquidemedicalsystems.com [1] Monnal T75 (CO 2 )/ Air Liquide Medical Systems APPLICATION AREA OPERATING CONDITIONS Application: Patient categories: Weight: Intensive
Dräger Ventilation Mini Manual Brief explanation of ventilation modes and functions
Dräger Ventilation Mini Manual Brief explanation of ventilation modes and functions 1 TABLE OF CONTENTS 3 Table of contents PC-BIPAP vs. PC-AC Pressure Control Biphasic Positive Airway Pressure vs. Pressure
The bridge to more efficient care PONTA SUPPLY BEAMS
MT-4159-2007 The bridge to more efficient care PONTA SUPPLY BEAMS 02 PONTA SUPPLY BEAMS more versatile MT-4056-2007 MT-3978-2007 MT-3965-2007 MT-3987-2007 Uniting improved care with individual flexibility
Reference Case: Continuous mobile patient monitoring
Reference Case: Continuous mobile patient monitoring Significantly lower investment costs, increased telemetry coverage, and efficient project implementation. According to the management team at Memorial
MT-2439-2003. Monitoring and IT Solutions for supporting patient safety and care INFINITY IN-HOSPITAL TRANSPORT SOLUTIONS
MT-2439-2003 Monitoring and IT Solutions for supporting patient safety and care INFINITY IN-HOSPITAL TRANSPORT SOLUTIONS 02 Save time and effort MT-6943-2006 Continuous monitoring, uninterrupted surveillance
D-39740-2011. Next-generation LED phototherapy NanoBlu 500
D-39740-2011 Next-generation LED phototherapy NanoBlu 500 02 Is there a powerful phototherapy device that s really compact? D-3534-2011 03 BETTER TREaTMENTS SuPPoRT BETTER outcomes The effective treatment
Dräger PARAT Escape Hoods
Dräger PARAT Escape Hoods Airborne toxins present an immediate danger to the health of a workforce. When environments turn toxic, a fast, safe escape is crucial. Dräger PARAT Escape Hoods are designed
Vista 120 Patient Monitor
Vista 120 Patient Monitor The Vista 120 offers essential monitoring capabilities at an exceptional value and meets the needs of a variety of care environments for adult, paediatric and neonatal patients.
Ventilation modes in intensive care
Ventilation modes in intensive care Karin Deden Important note This brochure does not replace the instructions for use. Prior to using a ventilator the corresponding instructions for use must always be
Dräger Communication Systems
Dräger Communication Systems Clear and trouble-free communication is a must during deployments. Especially when it comes to environments with high noise levels such as fires and other disasters, it s crucial
D-36-2011. Curves and Loops in Mechanical Ventilation Frank Rittner Martin Döring
D-36-2011 Curves and Loops in Mechanical Ventilation Frank Rittner Martin Döring Curves and Loops in Mechanical Ventilation Frank Rittner Martin Döring 5 Contents Ventilation curve patterns 6 n Pressure-time
Infinity Acute Care System Monitoring Solution
Infinity Acute Care System Monitoring Solution Transform your clinical workflow with the Infinity Acute Care System monitoring solution. This innovative two-screen solution opens the door to a new dimension
D-9282-2009. Gas supply secure at a glance DRÄGER ALARM MANAGEMENT SYSTEM
D-9282-2009 Gas supply secure at a glance DRÄGER ALARM MANAGEMENT SYSTEM 02 Alarm Management System The central gas supply is one of the hospital s life support systems, and as such is subject to special
Auto Flow 20 Questions 20 Answers. Joseph Fitzgerald
Auto Flow 20 Questions 20 Answers Joseph Fitzgerald Important Notice: Medical knowledge changes constantly as a result of new research and clinical experience. The author of this introductory guide has
«The compact and mobile testing device for ventilators.»
«The compact and mobile testing device for ventilators.» Developed for mobile use simple. compact. reliable. Simple operation CITREX is simple and intuitive to operate. The colour screen offers excellent
Sunderby Hospital: implementing patient monitoring on an existing hospital network
Sunderby Hospital: implementing patient monitoring on an existing hospital network Sunderby Hospital in Luleå, Sweden, needed to replace its 12-year-old patient monitors hospital-wide and made the strategic
VENTILATION SERVO-s EASY AND RELIABLE PATIENT CARE
VENTILATION SERVO-s EASY AND RELIABLE PATIENT CARE Critical Care SERVO-s 3 SERVO-s SIMPLY MAKES SENSE MAQUET THE GOLD STANDARD Leading the way: MAQUET is a premier international provider of medical products
MEDUMAT Easy CPR The Guiding Emergency Ventilator
MEDUMAT Easy CPR The Guiding Emergency Ventilator MEDUMAT Easy CPR The Guiding Emergency Ventilator Safety is on Duty Although patient resuscitation is not part of your daily work, you are regularly confronted
For every breath he takes. Trilogy200 ventilator s added sensitivity lets you breathe easier knowing your patients are where they belong home.
For every breath he takes Trilogy200 ventilator s added sensitivity lets you breathe easier knowing your patients are where they belong home. Sensitive to your patients needs Trilogy200, a portable life-support
The column to efficient care DRÄGER GEMINA DUO
MT-0798-2008 The column to efficient care DRÄGER GEMINA DUO 02 Dräger a century of care competence Today, hospitals are under increased pressure to provide state-of-the-art care with less staff and on
Boaray 700 Anesthesia Machine
Boaray 700 Anesthesia Machine Features CE certification. 15 inch colored LCD, touch screen setting, big font display, free changeable angles of views. Various ventilation modes - VCV, PCV, SIMV+VCV, SIMV+PCV.
Infinity M540 monitor
Infinity M540 monitor Now you can streamline workflow and support patient safety with a single monitor that accompanies the patient from admission to discharge. The ergonomic Infinity M540 provides continuous
Monitoring and It solutions for supporting patient safety and care. InfInIty
D-1161-2009 Monitoring and It solutions for supporting patient safety and care InfInIty bedside solutions 2 D-1170-2009 Monitoring vital signs is integral to the care of critically ill patients. You need
The centrepiece of a complete anaesthesia workstation
The centrepiece of a complete anaesthesia workstation IntelliSave AX700 anaesthesia machine A slim design with rich functionality To develop the first Philips-branded anaesthesia machine, we listened to
D-94164-2013. Gentle for the newborn, efficient for you. DRÄGER JAUNDICE METER JM-105
D-94164-2013 Gentle for the newborn, efficient for you. DRÄGER JAUNDICE METER JM-105 2 Assessing jaundice risk without the trauma D-94313-2013 D-7346-2009 While neonatal jaundice or hyperbilirubinemia
Karlstad Central Hospital, Sweden Creating an infection-controlled NICU
Karlstad Central Hospital, Sweden Creating an infection-controlled NICU After extensive research, planning, and visits to other hospitals and the Dräger Design Center, Karlstad Central Hospital replaced
Aliseo Anesthesia system
Aliseo Anesthesia system Cost effective technology in anesthesia Features Ventilator Electrically driven Volume controlled, ACV, electronic PEEP Ventilation with ambient air Stand-by mode at end case Direct
Table of contents. Exercise 1 Passive exhalation port 13. Exercise 2 Active exhalation valve 15
Trilogy workshop Table of contents Trilogy Workshop Introduction 4 Trilogy100 circuit options 5 Trilogy200 circuit options 6 Breath types 6 Pressure modes 7 Volume modes 7 Waveforms 7 Sensitivity 7 User
Proton therapy Process support with anesthesia
Proton therapy Process support with anesthesia In October 2009, Dräger talked to Dr. Morten Eckermann, head/director of the anesthesia department for the Munich Rinecker Proton Therapy Center (RPTC, Fig.
INTRODUCING RESMED S. Home NIV Solutions. S9 VPAP ST-A with ivaps S9 VPAP ST. Why choose average when you can choose intelligent?
INTRODUCING RESMED S Home NIV Solutions S9 VPAP ST-A with ivaps S9 VPAP ST Why choose average when you can choose intelligent? Now you can provide intelligent air through ResMed s intelligent Volume-Assured
Infinity Central Monitoring and Remote Access Solutions
Infinity Central Monitoring and Remote Access Solutions Reaching beyond the point of care Emergency Care Perioperative Care Critical Care Perinatal Care Home Care Because you care At Dräger, we re committed
Impact Uni-Vent 754 Portable Ventilator
Impact Uni-Vent 754 Portable Ventilator Description - Indications- Contraindications- Side Effects- Special Considerations- The Uni-Vent 754 Portable Ventilator is a portable electronically controlled,
Sample Usage Protocol Jaundice Meter JM-105
D-94164-2013 Sample Usage Protocol Jaundice Meter JM-105 This Sample Usage Protocol is provided as a template for creating a facility or department-specific protocol for using the Dräger Jaundice Meter
DrägerSensor EC Electrochemical Sensors Sensor for Fixed Gas Detectors
DrägerSensor EC Electrochemical Sensors Sensor for Fixed Gas Detectors Faster response higher accuracy greater stability longer life. Dräger electrochemical sensors offer all these benefits. The robust
The Anesthesia Ventilator
The Anesthesia Ventilator Why is the piston replacing the bellows? For many decades, and millions of anesthetics, the bellows anesthesia ventilator has been a safe and effective clinical device. Indeed,
The intelligent solution for the mobile ICU
The intelligent solution for the mobile ICU www.hamilton-medical.com/t1 Supporting you in saving lives! The HAMILTON-T1 ventilator features a compact, powerful design that increases the availability of
Anesthesia Solutions. Prima SP2 Anesthesia Systems. The Future of Anesthesia. Partnership for Life
Anesthesia Solutions The Future of Anesthesia Prima SP2 Anesthesia Systems The Penlon Anesthesia System Range provides the user with their choice of advanced, easy to use anesthesia systems u Advanced
Dräger X-plore 8000 Hoods, helmets, visors and masks
Dräger X-plore 8000 Hoods, helmets, visors and masks The innovative Dräger X-plore 8000 headpieces are an integral part of our new powered air-purifying respirator (PAPR). Both the loose- and tight-fitting
Rosemount 333 HART Tri-Loop
Product Data Sheet Rosemount 333 Rosemount 333 HART Tri-Loop HART-TO-ANALOG SIGNAL CONVERTER Convert a digital HART signal into three additional analog signals Easy to configure and install Accessory product
BIPAP Synchrony TM AVAPS
BIPAP Synchrony TM AVAPS Product Presentation V1.6 Contents Home NIV Solution introduction BiPAP Technology and Auto-Trak algorithm Consensus conference, Chest 1999 The AVAPS algorithm The AVAPS settings
Curves and Loops in Mechanical Ventilation. Frank Rittner Martin Döring
Curves and Loops in Mechanical Ventilation Frank Rittner Martin Döring Curves and Loops in Mechanical Ventilation Frank Rittner Martin Döring 5 Contents Ventilation curve pattern Pressure-time diagram
Trilogy200. Proximal pressure line. Exhalation valve line. Quick start guide. Overview. Circuit set-up. Set-up screen. Prescription set-up
Trilogy200 Proximal pressure line Exhalation valve line Quick start guide 1 2 3 4 Overview Circuit set-up Set-up screen Prescription set-up 1 Overview 4 Porting block Detachable battery Air inlet and grey
Two Steps forward in Ventilation. Ernst Bahns. Because you care
Two Steps forward in Ventilation Ernst Bahns Because you care Important Note: Medical knowledge changes constantly as a result of new research and clinical experience. The author of this introductory guide
Operator s Instruction Manual
Operator s Instruction Manual Part Number: 4117102-005 Rev: Fabius GS Software Version 1.3n Date: 12 September 2003 2003 Draeger Medical, Inc. Fabius GS Warning: For a full understanding of the performance
VELA. ventilator user guide. Critical care ventilation
VELA ventilator user guide Critical care ventilation Table of contents VELA ventilator model matrix...1-2 Panels...3-8 Circuit assembly...9-12 Primary controls...13-16 Extended Functions...17-19 Operational
Sensors / Modules / Monitors. Breath Gas Sensing and Monitoring. For life supporting systems in intensive, emergency and ambulant care
Sensors / Modules / Monitors Breath Gas Sensing and Monitoring For life supporting systems in intensive, emergency and ambulant care Your competent partner for breath gas sensing and monitoring EnviteC
Anesthesia Information Management DRÄGER INNOVIAN ANESTHESIA
D-24993-2010 Anesthesia Information Management DRÄGER INNOVIAN ANESTHESIA D-24994-2010 Imagine a solution that puts the focus back on the patient by automating the anesthesia patient record giving you
Impact Uni-Vent 750 Portable Ventilator
Impact Uni-Vent 750 Portable Ventilator Description - Indications- Contraindications- Side Effects- Special Considerations- The Uni-Vent 750 Portable Ventilator is a portable electronically controlled,
Fabius GS. Inhalation Anesthesia Machine Software 3.n Operating Instructions. Because you care
Fabius GS WARNING: For a full understanding of the performance characteristics of this equipment, the user should carefully read this manual before operating. Inhalation Anesthesia Machine Software 3.n
From AARC Protocol Committee; Subcommittee Adult Critical Care Version 1.0a (Sept., 2003), Subcommittee Chair, Susan P. Pilbeam
AARC - ADULT MECHANICAL VENTILATOR PROTOCOLS 1. Guidelines for Using Ventilator Protocols 2. Definition of Modes and Suggestions for Use of Modes 3. Adult Respiratory Ventilator Protocol - Guidelines for
Effective Treatment for Obstructive Sleep Apnoea
Effective Treatment for Obstructive Sleep Apnoea The Series of Positive Airway Pressure devices from DeVilbiss Healthcare is designed to meet the varied needs of people suffering from Obstructive Sleep
DC Electronic Loads 8500 series
Data Sheet DC Electronic Loads 8500 series 2400W 600 W - 1200 W 300 W Versatile & Economical DC Electronic Loads The 8500 series Programmable DC Electronic Loads can be used for testing and evaluating
Count On Us For Your Safety Dräger at your service
1 IMG_2390 D-39882-2011 Count On Us For Your Safety Dräger at your service Dräger at your service D-6638-2014_1_NEU 03 Contents Because every minute counts 4 Maximum safety from a single source 6 Quality
Dräger PSS 7000 SCBA Self-Contained Breathing Apparatus
Dräger PSS 7000 SCBA Self-Contained Breathing Apparatus Before you can protect the lives of others, you have to protect yourself. The Dräger PSS 7000 SCBA breathing apparatus provides unmatched comfort,
30-120 3 Phase Modular Finally the benefits of Modular ups are for all
MUST 30-120 3 Phase Modular UPS Finally the benefits of Modular ups are for all MUST 30-120 MUST means Modular UPS System Three-phase MUST 30-120 is an uninterruptible power supply with double conversion
Datex Ohmeda. Centiva /5. Service Manual Software rev. 2.1n
Datex Ohmeda Centiva /5 Service Manual Software rev. 2.1n Table of Contents 1 Introduction 2 Theory of Operation 3 Post-Service Checkout 4 Tests and Calibrations 1.1 What this manual includes 1-2 1.1.1
Technical Service Manual Babylog 8000/8000SC/8000 plus Intensive Care Ventilator
Technical Service Manual Babylog 8000/8000SC/8000 plus Intensive Care Ventilator Revision 10.0 6173.3 9029623 Emergency Care Perioperative Care Critical Care Perinatal Care Home Care Because you care Copyright
Oxygenation and Oxygen Therapy Michael Billow, D.O.
Oxygenation and Oxygen Therapy Michael Billow, D.O. The delivery of oxygen to all body tissues is the essence of critical care. Patients in respiratory distress/failure come easily to mind as the ones
MECHINICAL VENTILATION S. Kache, MD
MECHINICAL VENTILATION S. Kache, MD Spontaneous respiration vs. Mechanical ventilation Natural spontaneous ventilation occurs when the respiratory muscles, diaphragm and intercostal muscles pull on the
Introduction Insurance Industry Overview and Major Trends
Page 01 of 13 Page 02 of 13 Page 03 of 13 Page 04 of 13 Page 05 of 13 Page 06 of 13 Page 07 of 13 Page 08 of 13 Page 09 of 13 Page 10 of 13 Page 11 of 13 Page 12 of 13 Page 13 of 13 India- Corporate Headquarters
How To Use An Irius Pid Detector
SIRIUS PID & 4-Gas Detector [ Compact and Versatile for all your needs] SIRIUS [ Maximum versatility in one hand] The new SIRIUS PID Detector combines incredible performance, versatility and ease of use
Airway Pressure Release Ventilation
Page: 1 Policy #: 25.01.153 Issued: 4-1-2006 Reviewed/ Revised: Section: 10-11-2006 Respiratory Care Airway Pressure Release Ventilation Description/Definition Airway Pressure Release Ventilation (APRV)
Common Ventilator Management Issues
Common Ventilator Management Issues William Janssen, M.D. Assistant Professor of Medicine National Jewish Health University of Colorado Denver Health Sciences Center You have just admitted a 28 year-old
Datex-Ohmeda Critical Care Monitor
GE Healthcare Datex-Ohmeda Critical Care Monitor Comprehensive monitoring for the challenging Critical Care environment Critical Care monitor offers a flexible range of module frame options, displays and
Critical Care Therapy and Respiratory Care Section
Category: Section: Title: Critical Care Therapy and Respiratory Care Section Policy #: 03 Revised: 5/02 1.0 DESCRIPTION Clinical Ventilator Management Invasive and Noninvasive Positive Pressure Ventilation
Vivo 50/60 PC Software Help (english), version 3.0. 1. Introduction. 3. Dialogs. 7. Year data view. 8. Alarm view. 2. User interface. 9.
1. Introduction 1.1 Quick guide 1.2 Software 1.3 Software help 1.4 Patient data handling 2. User interface 2.1 Select function 2.2 The PC Software screen 2.3 Menus 2.4 Toolbar 2.5 Views and functions 2.6
GE Healthcare. Welcome to the future of anesthesia Aisys * Carestation *
GE Healthcare Welcome to the future of anesthesia Aisys * Carestation * The way you practice today may be different from the past. Diverse patient types and co-morbidities make your world challenging.
A ANESTHESIA SYSTEMS. intuitive effortless precise
A ANESTHESIA SYSTEMS intuitive effortless precise A growing family of A Series anesthesia systems intuitive The A5 and A3 have an easy to use user interface and ergonomic design that simplifies workflows.
Type: EASY719 DC RC Article No.: 274119. Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description
Type: EASY719 DC RC Article.: 274119 Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC Description 12 digital inputs (4 inputs available as analog inputs) 6 relay outputs LCD display
Digital pressure gauge for industrial applications Model DG-10-S, Standard version Model DG-10-E, Enhanced version
Electronic pressure measurement Digital pressure gauge for industrial applications Model DG-10-S, Standard version Model DG-10-E, Enhanced version WIKA data sheet PE 81.66 Applications Machine building
MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features
Central 48 V DC Power Supplies for PoE-Components MICROSENS Description Active network equipment which is supporting the Power-over-Ethernet functions, typically requires a powerful 48 V DC power supply.
PIEZOMETER AIRFLOW MEASURING RING
PIEZOMETER AIRFLOW MEASURING RING M.K. Plastics is pleased to introduce The Piezometer Airflow Measuring Ring, now available as an accessory for our steel Axijet fans. The system consists of a Piezometer
Thyristor-controlled power supplies and battery chargers
Thyristor-controlled power supplies and battery chargers Input voltage: 115 / 230 VAC, single phase, 50 / 60 Hz or 208 / 400 / 480 VAC, three phases, 50 / 60 Hz Output voltage: 12 / 24 / 48 / 60 / 72 /
Volume Guarantee New Approaches in Volume Controlled Ventilation for Neonates. Jag Ahluwalia, Colin Morley, Hans Georg Wahle
Volume Guarantee New Approaches in Volume Controlled Ventilation for Neonates Jag Ahluwalia, Colin Morley, Hans Georg Wahle Important Notice: Medical knowledge changes constantly as a result of new research
T0118 T2118 T3118. Instruction Manual
Programmable indoor transmitter of temperature T0118 Programmable indoor transmitter of atmospheric pressure T2118 Programmable indoor transmitter of temperature, relative humidity and other derived humidity
Ventilators/Transport*
Ventilators/Transport* pneuton A (Pneumatic Transport Ventilator) pneuton (pronounced new ton ); a small, lightweight transport ventilator designed for use on patients from pediatric to adult in size.
Battery Powered Thermal Mass Flow Meters for Gases
red-y compact series product information Battery Powered Thermal Mass Flow Meters for Gases Digital advantage: Thermal Mass Flow Meters for Gases The flow meters red-y compact series are characterized
SINEAX U553 Transducer for AC Voltage
With power supply RMS value measurement Carrying rail housing P/0 Application he transducer SINEAX U55 (Fig. ) converts a sinusoidal or a distorted AC voltage into a load independent DC current or a load
ECMO AND LIFE SUPPORT SYSTEMS QUADROX PLS AND ROTAFLOW HARDWARE AND ACCESSORIES
ECMO AND LIFE SUPPORT SYSTEMS QUADROX PLS AND ROTAFLOW HARDWARE AND ACCESSORIES The Gold Standard Cardiovascular QUADROX PLS and ROTAFLOW 3 QUADROX PLS AND ROTAFLOW INNOVATIVE PERFORMANCE AND RELIABILITY
Ventilator Application of the Passy-Muir Valve David A. Muir Course Outline Benefits Review of the Biased Closed Position No Leak Passy-Muir Valves
Ventilator Application of the Passy-Muir Valve Michael S. Harrell, B.S., RRT Director of Clinical Education-Respiratory [email protected] (949) 833-8255 David A. Muir 23 year-old ventilator dependent