Type FTS/FTC. A.03.431e. Compliance with Standards. Uses. Features



Similar documents
Airfield Lighting. 8" Uni- or Bidirectional High-Intensity Inset Light (ILP-T) Product Description

PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES

PRODUCT SPECIFICATION

Nightspot High performance floodlights for discharge lamps and LEDs

LED LEONARDO 120 W. LED Fresnel SPOTLIGHT White light, either Tungsten or Daylight balanced Correlated Color Temperature

Industrial Linergy LED

morelux QUALITY HIGH & LOW BAY LIGHTING CATALOGUE 2003/04

Medical Lighting. XL4 Patient Light

Low Bay LED Light - 250W Metal Halide Equivalent - 12 LEDs - 40 Watt High Output LEDs

Nightspot A2 Floodlights for LEDs and high pressure discharge lamps

Searchlights - Introduction

STANDARD MICRO-D CONNECTORS

Toroidal Conductivity Sensor

AirFilm Camera Systems

POINT OBSTRUCTION LIGHTS POL INCANDESCENT POINTSPEC SERIES

Airfield Lighting Product Description F2.1 F22. Low Intensity Obstruction Light

V47 Series Temperature Actuated Modulating Water Valves

LEVEL GAUGES WITH MAGNETIC JOINT L 14 - L 22 - L 34

Structural Bolting. Notice the Grade 5 has a much smaller head configuration and a shorter shank then the A325 structural bolt. Rev.

Pressure monitoring equipment for oil-sf 6. bushings, type GOEK

SPECIFICATIONS FOR TENDER NO: PSNR/SCP/VKS/E 1635 ANNEXURE I TECHNICAL SPECIFICATIONS FOR LIGHTING HIGH MAST

ETC130 / 140 Inground Uplights - Gimbal LED. Presentation Overview

CRN5-5 A-FGJ-G-E-HQQE 3x230/400 50HZ

How To Use A Ds340 (Dsp)

ponto trasso DESCRIPTION CHARACTERISTICS - FLOODLIGHTS ADVANTAGES VERSIONS

Dialight. Vigilant LED High Bay - UL for Indoor and Outdoor Industrial Applications

Terminal Boxes Series 8146

Nightspot LED High performance floodlights for LEDs

Superlight Compact LED LED floodlights

Bringing good things ahead

INSTRUCTIONS THOROUGHLY BEFORE BEGINNING***************

CRN A-F-G-E-HQQE 3x400D 50 HZ

Outdoor Use Waterproof I/O Connectors (Optical / Modular / Electrical) FO-BH, FO-BC, NT5, JN2 / W Series

IEC Connectors. Introduction

NEW SIX-SEALS CUTTING RING. INTERNATIONAL INDUSTRIAL PATENT Nr of the 10/03/99 FLANKS AND DOES NOT REPLACE THE STANDARD RING CURRENTLY IN USE

CLICKBOND FASTENER OVERVIEW:

Volkswagen B3 Passat General-Engine 4 CYL. 19 Engine - Cooling System (Page GR-19)

Disabled Toilet Alarm. Contractor Pack. Installation & Operating Instructions

Standard Buccaneer - Ethernet

SHOT BLAST CABINET MODEL NO: CSB20B

design Mario Cucinella MAXIWOODY

Operating Instructions

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

Cable Plug acc. to DIN EN , Form A

Superlight Compact Nano

DANGER DANGER. General Information. Safety Is Your Responsibility. Ordering Parts. Contact Information

Flue Options. Ace Finest Finest Gold Best 30/40/50/60 Best 80. Flue Options Flue Options Flue Options Flue Options

PAINT BOOTH LIGHTING

MVX-Series Diesel Engine Air Shut Down Valves

Items Supplied. Frequency. Designation Description / Delivery Unit Order Number

SELECTION, APPLICATION & MAINTENANCE

HID/FLOODLIGHT: ATEX/IECEx FLAMEPROOF. Applications

LED Module SPECIFICATION. LED Module for Modular Platform Series. LED Platform Module with Fin

StorMax Cable and Interconnect Installation Instructions

SITRANS F flowmeters SITRANS F M

Bolted Connectors & Terminals

DOUBLE GATE KNIFE GATE VALVE

Chapter 9. Bonding and Grounding

System 8. ü ( System 8

FLEX by 3M Light Module System

ALARI LED PARKING, ROADWAY & AREA LIGHTING

Linkeo 19" freestanding cabinets

SMA Interface Mating Dimensions (Per MIL-STD-348)

SMARTY 160 POWER page 4-5 SMARTY 180 / 220 XL page 4-6 SMARTY TX 250 page 4-7. SMARTY TX 160 Alu page 4-8 SMARTY TX 220 Alu page 4-9

CUSTOM AUXILIARY FORWARD LIGHTING KIT

Two most common lock nut groups: 1-Prevailing Torque Type Lock Nuts:

Furniture Fittings Furniture Handles and Knobs

Linear Luminaire with LED Series EXLUX 6402/2

HID H4 BI-XENON FITTING GUIDE. Carefully read the following notes before starting work.

Guide rail bracket (for adjustable heads)

API Flanged Safety Relief Valves Series 526 CATALOG

6000 Series Buccaneer. 30 twist locking Tamperproof lock prevents accidental un-mating. Cat 5e shielded coupler Maintains shielding

1ZSE en, Rev. 8. Transformer bushings, type GOE and GOE(2) Technical guide

Product catalogue, pipe and sewer cleaning systems

RUBBER SLEEVE KNIFE GATE VALVE

POINT OBSTRUCTION LIGHTS POL EX LED v5 HAZARDOUS LOCATION

SMZ type 43 INTRODUCTION. The Radiall Type 43 coaxial connector range. Type 43 series - Features and benefits

LED DOWNLIGHT ONE 50XX SERIES

AXLE SHAFTS - FRONT Pontiac Bonneville MODEL IDENTIFICATION DESCRIPTION & OPERATION TROUBLE SHOOTING REMOVAL & INSTALLATION

Mini USB and USB 2.0-IP67 Connector System

Flanged and Butt-= Weld Type

Rittal s Comprehensive Family Of... NETWORK RACK SOLUTIONS

Technical Data. 7. Bearing Fits. 7.1 Interference. 7.2 Calculation of interference F B LLLLLLLLL( A-54

Guideline Laser Series

3-Component Measuring System

Smart Electromagnetic Flowmeter Open channel Flowmeter Detector

Explosion-Proof Electric Unit Heaters

Linear Luminaire for Fluorescent Lamps Series EXLUX 6001

Proportional pressure regulators VPPE

QM (1.78mm-.070") CONNECTORS-"MICRO 70"

T A B L E T 1 T E S T S A N D I N S P E C T I O N C A B L E P C U T A N D P C U T - A

DSD 70 Dual Channel Hall Effect Speed Sensor for Railway Applications, compliant with EN 50155

TechCut 4 Precision Low Speed Saw

Accessories for GF and RA machines

STEERING SYSTEM - POWER

Clear Glass Sensor. Ordering Information E3S-CR67/62. Optimum Sensor for Detecting Transparent Glass and Plastic Bottles

INFRARED RADIANT HEATERS. air heaters

Inrush Apparent power (VA) Flow Characteristics/Weight. Port size Rc. Valve model VS VS VS VS VS

Section 21. Telecommunication Hardware. BuyLog Catalog 21-1

Residential Deck Safety, Construction, and Repair

Transcription:

Fig. : FTS--065 Taxiway Centre Line, Stop Bar and Intersection Medium Intensity Inset Light Type FTS/FTC Compliance with Standards FAA: Fittings for straight sections in compliance with FAA L-85A and L-85C specification, AC50/55-6 (current edition) Fittings for curves in compliance with FAA L-85B and L-85D, except horizontal light distribution. ICAO: In compliance with Annex, Vol. I, para 5.. NATO: In compliance with STANAG 6. Fig. Uses Centre line taxiway lights, on straight and curved sections and on rapid exit taxiways. Taxiway stop bar and intermediate holding position. Apron lights, to assist aircraft docking manoeuvres. Guard lights where required. Features Part of a comprehensive range of 8 and inch diameter inset lights covering all aviation ground lighting requirements. Lightweight, sturdy, low-energy and environment friendly lighting fixtures (no cadmium plating). Designed and built with simplicity and ease of maintenance in mind. Extensive use of aluminium alloys reduces fixture weight and eases handling in the field. Many components are common to all F-range lights. Low protrusion above ground (0 mm) reduces vibrations induced in aircraft landing gear and in lighting fixture itself, thereby increasing lifetime, particularly for the lamps. Shallow gully in front of lens windows maintains optimal light output under heavy rainfall. Smooth outer surface of light cover avoids tire damage and makes light less sensitive to snowplows. Outer lenses mechanically clamped to light cover through moulded, replaceable seals. Lens replacement by airport maintenance personnel is fast and easy and does not require any sealing compound or resin. No optical adjustment required after replacement of lamp, lens or reflector. Long life halogen lamps. 000 hours at full intensity, up to 000 hours in practical use. Standard adaptor rings for installation on FAA deep bases. Specific rings available to fit mounting bases and seating rings to other standards. Specific tools have been developed to ease installation and subsequent maintenance. Plug for pressure-testing of fixture after overhaul. Low-temperature lights. Temperature elevation at centre of top cover remains below 60 C ICAO specified limit. A.0.e

Construction. High tensile strength screw with washer (). Aluminium alloy cover. Lens with retainer and gaskets. Prefocus halogen lamp 5W, 65W or 00W - 6.6 A 5. Die cast aluminium alloy inner cover 6. Seal 7. FAA L-8 -pole plug moulded on heat resistant wires 8. Wire clamp with grommets 9. Terminal block 0. Film disc cut-out (optional). Optical assembly. Filter with filterspring. O ring seal. Finish Aluminium alloy cover, inner cover and optical assembly. Plain stainless steel hardware. Electrical supply 6.6 A through an isolating transformer (cat. leaflet A.06.0). Two or more fittings may be series-connected and fed from an isolating transformer making use of optional film disc or electronic cut-outs. 0 9 8 7 5 6 Fig. Fig. : FTC--065

Selection chart Use Description CAT. I - II CAT. III Taxiway centre line Intersection and guard lights Type Lamp power Filters Distribution curve Fig. FTS--05-W 5 W 6. FTC--05-W 5 W 6. FTS--05-N 5 W 6. FTS--065-W 6. 6.5 Type FTS--065-W FTC--065-W FTS--065-N FTS--00-W FTC--00-W Lamp power 00 W 00 W Stop Bar Filters HT HT Distribution curve Fig. 6.6 6.7 6.8 6.9 Use Description CAT. I - II CAT. III 6.0 Fig. 5 Photometric performances Lamps: 5, 65 or 00 W - 6.6 A PKX0d prefocus halogen lamp with nominal lifetime of 000 hrs. Taxiway centre line intersection and guard lights Colour Fig.* Performances (Typical data) Average Main beam spread Intensity Cd Horiz.( ) ( ) Stop bars Colour Fig.* Performances (Typical data) Average Main beam spread Intensity Cd Horiz.( ) ( ) CAT. I-II FTS--05-W FTS--05-W FTC--05-W FTC--05-W 6. 6. 0 97 76 5-0 to -0 to to to to to CAT. I-II FTS--065-W FTC--065-W 6.6 6.7 79 6-0 to to to CAT. III FTS--05-N FTS--05-N FTS--065-W FTS--065-W 6. 6. 6.5 85 68 7 89 8 -.5 to +.5 -.5 to +.5-0 to -0 to to 0 to 0 CAT. III FTS--065-N FTS--00-W FTC--00-W HT HT 6.8 6.9 6.0 5 7 -.5 to +.5-0 to to 0 * All curves shown are for green light.

light 5 W Lamp light Lamp Max. 70 Cd Min. 86 Cd -0 6 8 0 8 Hor. FTS--05-W Fig. 6. Max. 08 Cd Min. 5 Cd -0 6 8 0 8 Hor. FTS--065-W Fig. 6.6 light 5 W Lamp light Lamp Max. 0 Min. 8 Cd - 0 8 6 0 8 + Hor. FTC--05-W Fig. 6. Max. 79 Cd Min. Cd - 0 8 6 0 8 + Hor. FTC--065-W Fig. 6.7 Degr FTS--05-N Fig. 6. 00 Cd 00 Cd Max. 8 Cd Min. 76 Cd light 5 W Lamp -0 6 8 0 8 Hor. Degr FTS--065-N Fig. 6.8 00 Cd Max. 6 Cd 00 Cd Min. 8 Cd light Lamp -0 6 8 0 8 Hor. FTS--065-W Fig. 6. 00 Cd 00 Cd Max. 7 Cd Min. 7 Cd light Lamp -0 6 8 0 8 Hor. 0 FTS--00-W Fig. 6.9 00 Cd 00 Cd Max. 8 Cd Min. 9 Cd light 00 W Lamp -0 6 8 0 8 Hor. 0 Cd light Lamp 0 Cd light 00 W Lamp Max. 69 Cd Min. 88 Cd - 0 8 6 0 8 + Hor. Fig. 6.5 Max. 8 Cd Min. 80 Cd - 0 8 6 0 8 + Hor. FTC--00-W Fig. 6.0

Installation & Outline Dimensions (mm) Installation ) On a shallow base (Fig. 7-8). 9 0 dia. dia. 0 dia. 8 This method is used in existing pavements. The 8 or dia. base is sealed by means of resin. Correct positioning and levelling are obtained with a jig with sighting telescope. Wires between the light and the isolating transformer are installed in sawcuts in the pavement filled with resin. Mounting on existing or new larger diameter bases is made possible by means of dedicated adaptor rings. 75 5 5 Fig. 7 Installation on 8 dia. shallow base. Light. HPI Base. Secondary wires. Resin ) On a FAA L-868B size B steel base (Fig. 9). This method of installation is used when building new or resurfacing existing taxiways. The 8 dia. FTS or FTC light is mounted in a 8 to dia. adaptor ring bolted on the base. The bases are interconnected by means of conduits protecting the cables. The isolating transformer is installed under the light or better, in a separate pit. See catalogue leaflet A.05.0. For detailed information, please refer to the mounting instructions supplied with the fittings. ADB s technical team is at disposal of users and contractors to provide guidance and advice in order to help solving any particular dia.,5 installation problem. 0 dia. 0 dia. 8 Ordering code 55-60 7 Fig. 8 75 Standard: 60; Option: 00, 500. 0 9 dia. 0 Installation on dia. shallow base dia. 05 5. Light. Adaptor ring. Shallow base. Secondary wires 5. Resin 5 6 FTS 0 GY S Location Straight section = FTS Curved section = FTC Beams Unidirectional = Bidirectional = Lamp power x 5 W = 05 x = 065 x 00 W = 00 Beam width Narrow (FTS only) = N Wide = W Beam colour Left hand beam = G = Y Right hand beam = R HT = M Blank = N Mounting Without base = 0 With 8 shallow base = Special requirements to be specified in full text = S Options Film disc cut-out Electronic cut-out Special executions adapted to specific National Standards available. Please contact ADB for detailed information.. Light. Adaptor ring. Deep base. Primary connectors 5. Rubber grommet 6. Conduit Fig. 9 8 7 Installation on FAA L-868 base 7. Isolating transformer 8. Spacer 9. Outer earth terminal 0. Inner earth terminal. Secondary connector. Flange ring Complete, delete or modify as necessary. Packing Data FTS/FTC light with lamp, without shallow base nor adaptor ring: net weight:.7 kg. In cardboard box: 0 x 0 x 00 mm: gross weight:.9 kg. FTS/FTC light with lamp and shallow base: net weight: 5.5 kg. In cardboard box: 0 x 0 x 50 mm; gross weight: 5.7 kg.

Suggested specification The taxiway centre line, stop bar and inter-section inset lights shall comply with FAA L-85 specifi-cation (AC 50/55-6 current edition). Their performance shall meet all requirements of ICAO Annex, Vol. I, para. 5.. The lights shall be suitable for use under Category I, II and III conditions, when fitted with the proper lamp. The latter, rated 5, 65 or 00 W, shall be a prefocus halogen lamp with an expected life of not less than 000 hrs at full intensity. The prism shall be user-replaceable without need to apply sealing compound. The use of dichroic filters shall not be permitted in order to avoid colour shift-ing. The projection above ground level shall not exceed 0 mm. The absence of a negative slope in front of the lens shall guaran-tee an optimal light output even in the worst weather conditions. The top part of the lights shall be made from aluminium alloy. Watertightness shall be ensured by means of two seals. Grommets shall be used for the entry of the wires inside the inner cover to allow for easy replacement of accidentally damaged wires. All components shall be corrosion proof without using environment aggressive metal protective coatings. The lights shall resist all stresses imposed by impact, rollover and static loads of present day aircraft without damage to the light or aircraft or vehicle tires. The optical unit shall suit for mounting on a 8 dia. base or on larger diameter bases by means of adaptor rings. The lights shall use as far as possible the same components as those of the runway centre line and touchdown zone lights of the same family to reduce the quantity of spare parts. Registered Office: ADB Airfield Solutions Leuvensesteenweg 585 B-90 Zaventem Belgium Phone: + () 77 Fax: + () 776 info.adb@adb-air.com www.adb-air.com www.comith.be ADB all rights reserved order number DOCA0EV subject to modifications