StorMax Cable and Interconnect Installation Instructions
|
|
|
- Barnaby Stokes
- 9 years ago
- Views:
Transcription
1 StorMax Cable and Interconnect Installation Instructions 1 StorMax Cable and Interconnect Installation Instructions StorMax Cable and Interconnect Installation Instructions... 2 Welcome to the StorMax System... 2 Cable Addressing and Display Names... 2 Cable Type... 3 Deciding on Uni or Multi-Cable Installation... 3 Roof Loading`... 3 Suspension Type... 5 For All Cable Installations... 7 Cable Installation with Angle Base Style Suspension... 7 Cable Installation with Hanger Style Suspension... 7 Cable Installation with Puck Style Suspension in CDR/HDR Cables... 7 LEAD ROUTING... 8 Options for Lead Routing... 8 CAP100 Rule... 8 Lead and Interconnect Routing... 8 Lead Routing for UNI Cable applications... 8 Lead/Interconnect Routing for Multi Cables with INT2-XXLD Hub Termination... 9 Interconnect Routing from INT2-XXLD Hub... 9 Cable Tie-Down... 9 Cable Tie-down... 9 Do not... 9
2 StorMax Cable and Interconnect Installation Instructions 2 StorMax Cable and Interconnect Installation Instructions Welcome to the StorMax System Thanks for your purchase, and welcome to StorMax family of products. You have invested in a technology that will grow with your evolving storage management needs. There are a couple of things you need to understand about the system, so please take a few minutes to read these instructions prior to installation. Cable Addressing and Display Names Every cable must be programmed to a different address. Cables can be re-programmed multiple times, with either the StorMax monitor or through the PC with the StorMaxPro system. The address enables the system to recognize the cable, so as to display and store data in the right place. There is a label stuck to the head of the cable with an A number, which by default is A1, unless pre-programmed otherwise. Once the cables have been programmed with addresses, the A# becomes a background part of the system. Cables will then be associated by a Display Name such as Bin 26 Cable 3, which you program into the monitor only, and not the cable. In multi-cable applications, the display name of the center cable is typically C1. If no center cable, C1 is the north most cable in the inner ring of cables, or the first cable clockwise from the roof ladder, with the balance of cables following suit in a clockwise direction (refer to StorMax cables installation diagrams).! Important: A unique address must be programmed into each cable prior to connecting cables together. To learn more about programming, refer to the StorMax monitor instruction book.
3 StorMax Cable and Interconnect Installation Instructions 3 Cable Type OPI offers a range of cable types, depending on grain depth and application. Be sure you have selected the appropriate cable for you application. Unit MDR2 CDR2 HDR2 SE3 Cross Section (Actual Size) Size (LxW) inch mm 0.67 x x x x x x Ø 5.0 Ø Tube ID (min.) inch mm Steel Construction inch 2 x 1/8 2 x 3/16 2 x 7/32 - Tensile lb Strength kg Theoretical lb/ft Load *** kg/m Maximum lb Tie-down kg Application Range feet m > 100 > 30 All XDR2 Tubes ***Important: Theoretical Load is the typical load per foot or meter of cable, based on dry, clean, flowable cereal grain. Loads will increase significantly due to tough, damp, dirty, frozen, bridged or high density grain, as well as cable location, anchoring mechanism, bin or unloading type and discharge rate. Read StorMax Instructions for proper cable installation and consult Bin Manufacturing Co. for cable support recommendations. OPIsystems Inc. is in no way liable for damage caused by excessive loading and/or cable failure. Deciding on Uni or Multi-Cable Installation OPI recommends one centre cable in bins diameters less than 24 (7.3m). Bins 24 and over require 3 or more cables/bin. Please refer to the Multi-Cable Recommendation brochure and Installation instructions for recommendations on number and placement of multi-cables. Roof Loading! Important: MDR2 cables can generate loads exceeding 16lbs/ft (24kg/m) of depth. CDR2/HDR2 cables can generate loads exceeding 20lbs/ft (30kg/m) of depth. OPI will not be responsible for roof failure. Consult your Bin Supplier to be sure the structure is designed to withstand the design load. Although grain bins are designed for peak loads, they cannot withstand any measurable load away from the peak or sidewall. These load estimations are based on normal applications, such as dry, flow-able small grains. Certain conditions, which may generate even higher cable loads, should be avoided. Examples include:
4 StorMax Cable and Interconnect Installation Instructions 4 Never secure cables with a tie-down material that is more than 25% of the cable breaking strength. This equates to; o 850 lbs (385 kgs) for the MDR2 series o 2100 lbs (950 kgs) for the CDR2 series o 2,800 lbs (1,270 kgs) for the HDR2 series. Do not freeze grain, particularly tough grain that can ball-up on the cable and generate extreme loads, especially during unloading. If grain temperatures are at or below freezing, be sure to re-warm prior to unloading. Outer radius cables in hopper-bottom bins can generate extreme loads, due to the unloading characteristics of hopper-bottomed bins. It is recommended to not extend outer radius cables into the hopper on larger diameter bins. This means using free weights, rather than tie-down, to secure the cable bottom. OPI offers external cable support brackets that can be used with MDR2 Tubes to a maximum grain depth of 50 (10m); CABL-BRK3 two-rib bracket up to 35 maximum cable length CABL-BRK1 four-rib bracket for cables less than 12 from centre, application CABL-BRK2 four-rib bracket for cables more than 12 from centre, application Refer to OPI Temperature Cable Support Spec Sheet.
5 StorMax Cable and Interconnect Installation Instructions 5 Is Cable Length > 50 Feet? Does the application involve extreme conditions such as: Tough grain being cooled or frozen Extremely high density material being stored Is the cable being tied down with a material greater than 25% of the cable tensile strength? Is the customer open to purchasing OPIsystems' cable support brackets? Recommend OPIsystems bracket supports for the simplicity of installation from the bin exterior and least cost alternative. Is Cable Length > 35 feet? Is the radius cable more than 12 feet from the center? Recommend bin manufacturer's cable support system. (OPIsystems can help with this information) Recommend OPIsystems CABL-BRK3 Recommend OPIsystems CABL-BRK1 Recommend OPIsystems CABL-BRK2 Suspension Type There are 3 possible methods of cable suspension; Angle Bases are used to a maximum cable length of 50 (15 m) for MDR2; 100 (30m) for CDR2. This is a simple installation, done from the outside of the bin. Application examples include centre cables drilled in through the roof-cap collar, or outer cables with
6 StorMax Cable and Interconnect Installation Instructions 6 external cable support brackets. Angle bases cradle the suspension head, and pivot to the slope of the roof, allowing for installation from an angle of 0-45 degrees. Hanger Suspension, for all cable series. Used when hanging cable directly from a suspension structure, typically on the underside of the roof. Puck style base for HDR2 cables, whereby the suspension head rests atop a suspension structure, either inside a CABL-E01 (OPI supplied) cast enclosure, or other suitable suspension surface.
7 StorMax Cable and Interconnect Installation Instructions 7 StorMax Cable Installation For All Cable Installations To avoid damage, cables must be free hanging and away from sharp surfaces. Keep in mind that grain movement will cause cables to drift, even if cables have been anchored. Cables should also be suspended out of the path of incoming grain to minimize wear. In bins with spreaders, adjust cable length according to where cables need to be installed to avoid mechanical interference and wear. Metal or heavy wall plastic tubing should also be placed over the cable along the zone of direct grain impact. Cable Installation with Angle Base Style Suspension 1. Drill a 1-1/8 (29 mm) hole vertically at the point of suspension. If drilling through multiple layers, be sure to drill holes straight up and down to avoid damage caused by cables rubbing against sharp surfaces. 2. If using Angle suspension, be sure to drill far enough away from vertical edge to allow for sufficient clearance and position the angle base with the raised printing pointing away from centre. If the bin cap interferes with the angle base, the angle can be moved down the rib and secured to the flat surface. 3. Install the cable by slowly uncoiling. Never drop the cable into the bin. 4. Secure the angle base by drilling self-tapping screws through the bottom section into the roof sheet. 5. Use the supplied rubber gasket to seal off the hole. Use silicone to complete the seal if necessary. 6. Be sure the top suspension is well seated into the angle base. Cable Installation with Hanger Style Suspension 1. For outer cable installation, make sure you have first read the Roof Loading section and consulted your bin supplier to be sure the suspension structure is of sufficient strength. 2. Select a suspension method that provides complete 360 free movement of the hanger. Lack of free movement can result in hanger and/or cable failure. 3. Loop the Hanger U bolt through a suspension hole on the rafter or through an eyebolt. When using eyebolts, be sure that the eyebolt is rated in excess of the cable breaking strength and installed with the eye parallel to the roof sheet rib, not on an angle so as to cause potential eyebolt failure. Also be sure to completely tighten and double-nut the U- bolt nuts after installation. 4. Install the cable by manual uncoiling. Never drop the cable into the bin. Cable Installation with Puck Style Suspension in HDR2 Cables 1. Be sure the suspension structure design exceeds the cable tensile strength. 2. Be sure the cable has free movement and is not rubbing against other surfaces. 3. Install the cable by manual uncoiling. Never drop the cable into the bin. 4. Bolt the puck to the base to eliminate movement. 5. Properly ground the cable head to a proven earth ground.
8 StorMax Cable and Interconnect Installation Instructions 8 LEAD ROUTING Options for Lead Routing 1. Uni-cable lead-out is the simplest application, whereby a single lead or interconnect cable is run to a StorMax hand-held monitor connection point. 2. Multi-cable with cable-cable-cable interconnect, whereby cables are joined by one common line in series. This method is used with a row of single-cable bins, or in flat stores. 3. Multi-cable to a central hub. This is the preferred method of routing, in that it is easier to perform diagnostics and service from one central access point. From here, interconnects can either be run to the interface, or to/from another bin. CAP100 Rule CAP100 refers to the maximum number of cables and leads or interconnects that can be joined per 2-Wire line, whether in series or to an INT2-XXLD Hub. The sum total of all devices grouped together onto a single 2-Wire line cannot exceed 100, based on; 1.33 per sensing cable 0.19 per sensor 0.12/foot (0.40/m) Retractable series sensing element (MDR2, CDR2,HDR2) 0.09/foot (0.30/m) lead or 2-Wire Interconnect cable 0.00 for INT2-XXLD. If the 2-Wire line is to exceed 100, the line has to be terminated into 3-Wire line on an INT3-XXLE 3-Wire Line Expander. CAP100 rules do not apply after the 2-Wire line has been switched into a 3-Wire line. Lead and Interconnect Routing Sensing cables can be ordered with lead attached and/or can be connected with INT2-XXXX 2- Wire Interconnect cable. Always run cables with the yellow tabbed male end pointing towards the next cable or interface device, whether an INT2-XXLD Line Divider, and INT3-XXLE Line Expander, RTU, or StorMax monitor. All interface devices are equipped with female sockets to receive more male tabs. Lead Routing for Uni Cable applications 1. If the sensing cable comes equipped with both male and female connectors, plug the female socket with silicone. 2. Run the male yellow tab end to the side of the bin. 3. Use the clips and self-tapping screws every 3-4 (1 m), to secure the lead. 4. Run the lead to a convenient location for plugging into the monitor. 5. An INT2-DOCK-SHORT docking station is required to protect the connector from weather and provide electrical protection to the cable assembly.! Important Cables must be plugged into docking station at all times when not in use.
9 StorMax Cable and Interconnect Installation Instructions 9 Lead/Interconnect Routing for Multi Cables with INT2-XXLD Hub Termination 1. If the sensing cable comes equipped with both male and female connectors, plug the female socket with silicone. 2. Route the lead back to center. Be sure to leave sufficient slack, so as to avoid stress during cable movement, particularly in Hanger applications. 3. Mount the INT2-XXLD Hub/s in a location that is both a) central to all the cables being collected and b) accessible to future service. Although it is best to group the cables per the side of the structure they are being collected from, it does not matters which cable goes into which 2-Wire input. 4. More than one INT2-XXLD Hub can be joined together on one 2-Wire Line, either when the bin has multiple hubs, or when joining from one bin to the next, so long as the CAP100 limit is not exceeded. In either case, INT2-XXXX Interconnect cables will be required to join from one hub to the next. N.B. When joining multiple dividers, an extra divider line is required to receive the male tab from the previous divider. Interconnect Routing from INT2-XXLD Hub 1. If running Interconnect from one bin to the next, be sure to secure the lead cable, through conduit or to a steel cable, to avoid damage by wind etc. 2. If running to ground for read-out with a StorMax monitor, use the clips and self-tapping screws every 3-4 (1 m), to secure the lead. 3. Run the lead to a convenient location for plugging into the monitor. 4. Both an INT2-GRND grounding cable and an INT2-DOCK-SHRT docking station are required when plugging two or more cables together. Cable Tie-Down Cables bottoms should be secured to minimize drift during loading and unloading, either by; a. Tie-down with a breakable material no stronger than 25% of the cable breaking strength, which is 850 lbs. (385 kg) for the MDR2 cable, 2100 lbs. (950 kg) for the CDR2 cable and 2800 lbs. (1270 kg) for the HDR2 cable. This will enable the bottom of the cable to break away under load so as not to impose excess loads on the cable and/or roof support. b. Free weights affixed to the bottom of the cable. Be sure the free weights are slender enough so as not to impose excessive additional load. Do not 1. Tie cables together in a horizontal ring. 2. Tie cables down with a material stronger than 25% of the cable strength. The tie-down must be the weakest part of the system, providing a break-point for the system and protection for the cable and suspension structure. 3. Use a large weight on the bottom of the cable, as this will generate unnecessary loads on cables and suspension.
Arctic Leash Instruction Manual Alaskan Products Company LLC.
Retractable Cord Reel for Engine Block Heaters Arctic Leash Instruction Manual Alaskan Products Company LLC. INSTALLATION INSTRUCTIONS This instruction manual is a reference guide for installing and operating
RATCHET RELEASE SHACKLE
RATCHET RELEASE SHACKLE INNOVATIVE PILING EQUIPMENT HYDRAULIC PILING HAMMERS EURO RATCHET RELEASE SHACKLE FOR STEEL ERECTION OPERATORS INSTRUCTIONS & SPARE PARTS LIST EXCAVATOR MOUNTED VIBRATORS EXCAVATOR
Volkswagen Jetta, Golf, GTI 1999, 2000 Brake System 46 Brakes - Mechanical Components (Page GR-46)
46 Brakes - Mechanical Components (Page GR-46) Front brakes Brake pads, removing and installing Brake pads, removing and installing FN 3 brake caliper, servicing FS III brake caliper, servicing Rear wheel
PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES
PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES BUSHING WITH PLUG CONNECTION WITH OUTER CONE PPS CHARACTERISTICS The PPS bushing can be used as a fixed section for the entry of medium
INSTALLATION OF A BAY WINDOW
INSTALLATION OF A BAY WINDOW Installation of a Bay Window These instructions relate to the replacement of an existing bay window or replacement of a straight window with a new bay window, in an opening
FG MOISTURE MONITOR Installation & Operation Manual
FG MOISTURE MONITOR Installation & Operation Manual Issue 3.0 7/20/10 1 Contents SERVICE AND TECHNICAL SUPPORT... 2 INSTALLATION:... 3 MOISTURE SENSOR INSTALLATION:... 3 SENSOR CONNECTOR:... 5 MONITOR
STEADYfast Stabilizer Installation Notes Fifth Wheel and Travel Trailers 11/23/13
STEADYfast Stabilizer Installation Notes Fifth Wheel and Travel Trailers 11/23/13 (See Supplemental Instructions for trailers with heavy duty round footplates and/or Power Leveling Systems) PHONE SUPPORT
INFRARED QUARTZ WALL HEATER
INFRARED QUARTZ WALL HEATER MODEL NO: IQ2000 PART NO: 6939004 MOUNTING & OPERATION INSTRUCTIONS GC0715 INTRODUCTION Thank you for purchasing this CLARKE Infrared Wall Heater. Before attempting to use this
Traditional Sonar and DSI Sonar Installation
Traditional Sonar and DSI Sonar Installation This document covers the installation of the transducer and display unit installation, which includes connecting the unit to power and installing the unit on
INSTALLATION INSTRUCTIONS FOR 2006-2009 VW MK5
CI100018 INSTALLATION INSTRUCTIONS FOR 2006-2009 VW MK5 Rabbit, Jetta 2.5L These instructions are applicable to vehicles equipped with either manual or automatic transmissions Thank you for choosing to
Awning Instructions. Standard Manual 1.5m to 4.5m
Awning Instructions Standard Manual 1.5m to 4.5m English Standard Manual Instructions Contents Warning 1.5m 3.0m Awnings 4 x Expansion bolts (2 per bracket)** 2 x brackets 1 x Awning 1 x Winder handle
AM/FM ANTENNA RELOCATION KIT
-J0 REV. 008-09-0 AM/FM ANTENNA RELOCATION KIT GENERAL Kit Number 766-09 Models This kit is used to relocate a fender-mounted AM/FM antenna to a Detachable Tour-Pak on specific model motorcycles. For model
5800 Temperature Sensor Cable Assembly
5800 Temperature Sensor Cable Assembly Removal and Replacement Instruction Sheet #60-4702-070 Revision D, January 14, 2013 Overview The 5800 has two refrigeration temperature sensors, one attached to the
Chapter 10 - Scaffolding Systems
Chapter 10 - Scaffolding Systems Contents Chapter 10 - Scaffolding Systems... 10-1 Check and Oil the Pump Jacks... 10-4 Set Pump Jack Brackets... Error! Bookmark not defined. Set Pump Jack Poles... 10-5
ADDING AN ELECTRIC AUXILIARY FAN TO RADIATOR STACK ON 03 ALPINE COACH
ADDING AN ELECTRIC AUXILIARY FAN TO RADIATOR STACK ON 03 ALPINE COACH The original design of the 03 Alpine Coaches (and perhaps other years as well) did not include any kind of engine fan engage mechanism
Dock Hardware & Accessory Products Catalog
Dock Hardware & Accessory Products Catalog Product Page # Product Page # Angle Brackets/Clips 8 Back Up Plate 5 Backing Plate/Hurricane Stop 10 Carriage Bolt Sets 4 Chain Retainer 10 Connector Pin Set
tidesmarine Smart Seal Temperature Alarm System Generation II Installation Instructions Starboard side cable
tidesmarine Smart Seal Temperature Alarm System Generation II Installation Instructions Starboard side cable Port side cable (with black cable tie attached) Power cable Preparing for Installation 1 Overall
1.8 CRANKSHAFT OIL SEALS
SERIES 60 SERVICE MANUAL 1.8 CRANKSHAFT OIL SEALS An oil seal is fitted between each end of the crankshaft and the bores of the flywheel housing and gear case cover to retain the lubricating oil in the
1000-LB. TRAILER JACK OWNER S MANUAL
1000-LB. TRAILER JACK OWNER S MANUAL WARNING: Read carefully and understand all INSTRUCTIONS before operating. Failure to follow the safety rules and other basic safety precautions may result in serious
Auto-belay Cable Replacement Process
Auto-belay Cable Replacement Process Version 2.00 WARNING: The air pressure in the auto-belay system is what causes the cable to be retracted when releasing the cable or climbing the wall with the cable
with installation dynafact boost GAUGE this manual is for use with systems 64050-64054
owners manual with installation instructions dynafact boost GAUGE this manual is for use with systems 64050-64054 GENERAL INSTALLATION PRACTICES This manual is an installation guide for all 1. Banks DynaFact
IMPORTANT DOCUMENTATION DO NOT DISCARD!
PART NO.: 6441-263C SERIES GRT 3 JAW PARALLEL GRIPPERS INFORMATION SHEET IMPORTANT DOCUMENTATION DO NOT DISCARD! Use this information sheet to assist with gripper installation and setup. File with maintenance
METHOD STATEMENT FOR INSTALLATION OF CABLE TRAY/TRUNKING/LADDER
Page 1 of 6 FOR INSTALLATION OF CABLE TRAY/TRUNKING/LADDER 0 Issued for Review & Comments Rev. Date Description Eng. A.H Prepared by Checked by Approved by Page 2 of 6 REVISION CONTROL SHEET REV. NO. DATE
Front axle components, overview
just a test. Front axle components, overview 40-1 General Information Load bearing components and parts of the suspension must not be welded or straightened. Vehicles without drive axle must not be moved,
AM/FM ANTENNA KIT (TOUR-PAK MOUNT)
-J077 REV. 008-0-0 AM/FM ANTENNA KIT (TOUR-PAK MOUNT) GENERAL Kit Number 7-98A Models For model fitment information, see the P&A Retail Catalog or the Parts and Accessories section of www.harley-davidson.com
Installation Manual. Solar Pool Heating System. Read the complete manual before beginning the installation
Solar Pool Heating System Installation Manual Read the complete manual before beginning the installation 1. Sizing the System Visit www.techno-solis.com to size the system using the sizing calculator.
Mounting Tripod Kit Installation Manual
Mounting Tripod Kit Installation Manual For use with Davis s wireless and cabled Vantage Pro2 weather stations, the Mounting Tripod simplifies installation. The tripod supports the Integrated Sensor Suite
DirectCommand Installation DirectCommand 3-Channel Spreader Kit
Note: Indented items indicate parts included in an assembly listed above Part Name/Description Part Number With Switch Box Quantity With Remote Switch Display Cable Kit 4100814 1 1 Power Control Relay
EZ-Steer Assisted Steering System
EZ-Steer Assisted Steering System Installation Instructions Platform Kit P/N 53059-21 Case IH Puma 165 Puma 180 Puma 195 Puma 210 New Holland T7030 T7040 T7050 T7060 Revision A June 2007 Part Number 53345-21-EU2
POLE MOUNT SYSTEM-3 INSTALLATION
1 May 2014 POLE MOUNT SYSTEM-3 INSTALLATION The Pole Mount System-3 is an easy to install and flexible system designed to allow ONE SYSTEMS loudspeaker products to be mounted to pole structures. The only
Installation Instructions
Installation Instructions S50-310 (Semi-Circular) S50-311 (Circular) Accu-Zone Infrared Control Conversion Kit for Terrazzo & Stainless Steel Classic Washfountains (Non-sectional) Table of Contents Pre-Installation
BILLET HEADLAMP WITH SHORT/TALL MOUNTS
-J099 REV. 00-0- BILLET HEADLAMP WITH SHORT/TALL MOUNTS GENERAL Kit Number 9-0, 9-0 Models Kit 9-0 is a -/ inch headlamp and kit 9-0 is a -/ inch headlamp. Both kits will fit the models listed in Table.
BBWX1 Satellite Weather Receiver. Installation and Maintenance Guide
BBWX1 Satellite Weather Receiver Installation and Maintenance Guide Rev FUSA 15JUL2007 Table of Contents Safety Precautions 3 Disclaimer. 3 Contents of Package. 4 Tools Required..4 Installation General
CAST IRON THE BASICS. Heatline - Cast Iron Radiators SMOOTH FLAT FILE TO REMOVE ANY SWARF. ONE TIME. ASSEMBLY. JOINTS SHOULD BE TIGHTENED.
CAST IRON THE BASICS 1. DO NOT LIFT ON YOUR OWN. 2. ONLY LIFT THE RADIATOR VERTICALLY. 3. DO NOT LIFT MORE THAN 8/10 SECTIONS AT ANY ONE TIME. 4. POSITION THE RADIATOR BEFORE FINAL ASSEMBLY. 5. THIS PRODUCT
Operations Manual SledStart H4 HID Light Kit
Operations Manual SledStart H4 HID Light Kit ` Table of Contents INTRODUCTION...1 SAFETY WARNING...1 PACKAGE CONTENTS...1 INSTALLATION INSTRUCTIONS...2 NOTES... 7 Copyright 2010 SledStart LLC All Rights
Canopy Surge. User Manual
Canopy Surge Suppressor User Manual SS00-UM-en Issue 2 May 2003 2003 Motorola, Inc. All rights reserved. Printed in the U.S.A Notices Safety Precautions: Before beginning your installation, please read
INSTALLATION MANUAL. Installation Instructions
INSTALLATION MANUAL Power-Pole Signature Series Shallow Water Anchor Installation Instructions CAUTION: Read this instruction manual carefully. Become familiar with the controls and know how to operate
UNIVERSAL MOUNTING SET (UMS) FOR ARTOLINK FSO EQUIPMENT
UNIVERSAL MOUNTING SET (UMS) FOR ARTOLINK FSO EQUIPMENT 1. DESIGNATION AND COMPOSITION OF THE SET. The present manual is meant for familiarizing with construction, mounting and operational regulations
BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS
BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS PLEASE READ COMPLETE INSTRUCTIONS BEFORE YOU BEGIN LEAVE INSTALLATION INSTRUCTIONS AND USER'S GUIDE WITH OWNER ALL ELECTRIC WIRING AND PLUMBING MUST BE DONE
DETACHABLE WINDSHIELD AND DOCKING HARDWARE KIT
-J00 REV. 00-- DETACHABLE WINDSHIELD AND DOCKING HARDWARE KIT GENERAL Kit Number -A, 0-, -, 0-, -, - 0, -0 Models These kits fit and later FXST, FXSTB, FXSTC, and and later FXDWG Harley-Davidson model
Transducer Installation
Transducer Installation This document covers the installation of all 83/200kHz, 50/200kHz and Downscan transducers using transom and shoot-thru hull installation methods, where applicable. This manual
ReachFree ID Installation Instructions For Portal TI, Sentinel and C-Start. Unitec www.startwithunitec.com
ReachFree ID Installation Instructions For Portal TI, Sentinel and C-Start Unitec www.startwithunitec.com Proprietary Information and Materials of Unitec, Inc. Such proprietary information and materials
Rear wheel brakes, servicing. Стр. 1 из 45. Note:
Volkswagen Touareg - Rear wheel brakes, servicing Стр. 1 из 45 46-2 Rear wheel brakes, servicing Rear brakes, FN 44 brake caliper, servicing Note: After replacing brake pads, depress brake pedal firmly
POLE MOUNT SYSTEM EX-3 INSTALLATION
May 2014 POLE MOUNT SYSTEM EX-3 INSTALLATION The Pole Mount System EX-3 is an easy to install and flexible system designed to allow ONE SYSTEMS loudspeaker systems to be mounted to pole structures. The
Florida Building Code 2004 SECTION 1009 STAIRWAYS AND HANDRAILS
Florida Building Code 2004 SECTION 1009 STAIRWAYS AND HANDRAILS 1009.1 Stairway width. The width of stairways shall be determined as specified in Section 1005.1, but such width shall not be less than 44
INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks
Securitron Magnalock Corp. www.securitron.com ASSA ABLOY, the global leader Tel 800.624.5625 [email protected] in door opening solutions INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate
FRONT BUMPER INSTALLATION INSTRUCTIONS 2007-2011 DODGE / MERCEDES SPRINTER
Aluminess Products Inc 9402 Wheatlands Ct. #A Santee, CA 92071 619-449-9930 FRONT BUMPER INSTALLATION INSTRUCTIONS 2007-2011 DODGE / MERCEDES SPRINTER Please read before beginning Stainless steel hardware
Cable Support System Guide for Andersen Bow, Bay, and Box Projecting Window Units
for Andersen Bow, Bay, and Box Projecting Window Units Congratulations! You have just purchased one of the many fine Andersen products. Proper assembly, installation and maintenance are essential if the
1. SAFETY RULES. 8. Avoid placing objects in the path of the blades.
1 1. SAFETY RULES 1. To reduce the risk of electric shock, insure electricity has been turned off at the circuit breaker or fuse box before beginning. 2. All wiring must be in accordance with the National
EZ-48-3AB-125-35 Weather Station Mounting Tripod and Mast
EZ-48-3AB-125-35 Weather Station Mounting Tripod and Mast EZ-125-35M 35 Mast Extension (Optional) EZ-125-SK Stake Kit (Optional) EZ-46-3 Tar Pad Kit (Optional) EZ-GWA Guy Wire Kit (Optional) Ambient Weather
In-Ground Basketball System Owners Manual
In-Ground Basketball System Owners Manual Customer Service Center N53 W4700 South Corporate Circle Sussex, WI 53089 U.S.A. Write Model Number From Box Here: WARNING! 3 Capable Adults REQUIRED TOOLS AND
Andersen Electric Window Opener for Andersen Awning and Roof Windows
W A Electric Window Opener Electric Window Opener for Awning and Roof Windows Congratulations! You have just purchased one of the many fine products. For ease of installation and continued enjoyment of
Awning Instructions. Full Cassette 1.5m to 6m
Awning Instructions Full Cassette 1.5m to 6m English Full Cassette Manual & Electric Instructions Contents Warning 1.5m - 3.5m Awnings 8 x Expansion bolts ** 2 x brackets 1 x Awning 1 x Winder 4.0m -
Part Name/Description Part Number Quantity. Power Cable 4000950-5 1
Note: Indented items indicate parts included in an assembly listed above Part Name/Description Part Number Quantity Power Cable 4000950-5 1 Raven Harness Adapter Kit 4100525 1 Installation Instructions
CUSTOM AUXILIARY FORWARD LIGHTING KIT
-J0 REV. 0--0 CUSTOM AUXILIARY FORWARD LIGHTING KIT GENERAL Kit Number -0, 0000 Models This Custom Auxiliary Lighting Kit adds lamps and turn signals to 00 and later FLHX model motorcycles. Additional
Step by step guide to installing your own Ku Band satellite dish
Step by step guide to installing your own Ku Band satellite dish If you don't feel comfortable installing your own system, your local TV Aerial or Handyman can easily follow these helpful guidelines for
Installation Instructions
Installation Instructions Page 1 of 16 January 2008 Equipment Parts, Trailer Hitch Ver 3.0 Accessory Development SUBJECT TRAILER HITCH KIT (US Only) - P/N 71 60 0 413 359 MODEL X5 (E70): Select Vehicle
LED MOTION ACTIVATED FLOOD LIGHT
Utilitech & UT Design are registered trademarks of LF, LLC. All Rights Reserved. ITEM #0611551, #0611550 LED MOTION ACTIVATED FLOOD LIGHT MODEL #SE1036-BP2-02LF0-U, SE1036-WH3-02LF0-U Français p. 10 Español
Air Conditioner Duct Construction & Repair
PROPER ROOF AIR CONDITIONER MOUNTING At Newmar, there are two different models of air conditioners available on all towable and motorized units. The different models are the Dometic Brisk and Penguin models,
This mount uses concrete parking bumpers and a Davis tripod to create a mounting solution for nonpenetrable
NON-PENETRATING FLAT ROOF MOUNT Application Note 18 For Any Davis Weather Station Installed on a Mounting Tripod Introduction This application note describes various mounting solutions for non-penetrable
Time needed: ~3h for lid replacement only. Add 1h for operation harness in lid and ~2h more for installing drive unit and cable harness in trunk.
DIY for replacing trunk lid and/or retrofitting electrical operation of trunk lid. This document is meant to be a support and give advice on the procedure but I will take no responsibility for any damage
INSTALLATION INSTRUCTIONS HUSTLER 4-BTV, 5-BTV TRAP VERTICAL WARNING INSTALLATION OF THIS PRODUCT NEAR POWER LINES IS DANGEROUS
INSTALLATION INSTRUCTIONS HUSTLER 4-BTV, 5-BTV TRAP VERTICAL WARNING INSTALLATION OF THIS PRODUCT NEAR POWER LINES IS DANGEROUS FOR YOUR SAFETY, FOLLOW THE INSTALLATION DIRECTIONS GENERAL DESCRIPTION:
Residential Deck Safety, Construction, and Repair
Juneau Permit Center, 4 th Floor Marine View Center, (907)586-0770 This handout is designed to help you build your deck to comply with the 2006 International Residential Building code as modified by the
FLAT ROOF BOX SPAN CARPORTS
AGS/NC/03 FLAT ROOF BOX SPAN CARPORTS Thank you for choosing this quality product. We strongly recommend that you read these instructions thoroughly. Please take your time and do not rush the erection
Wanda Technology Inc. Side Post Aluminum Umbrella OWNER S MANUAL
Wanda Technology Inc. Side Post Aluminum Umbrella Portofino II Series OWNER S MANUAL US Patents: 6,439,249 ; 6,692,135 ; 6,598,990 ; 6,966,667 6,945,263 ; 6,923,194 ; 6,830,058 ; 6,565,060 6,511,033 ;
3 IN 1 BATHROOM HEATER
3 IN 1 BATHROOM HEATER MODEL NO.: A515 - SH MINI FUNCTION: HEATER, EXHAUST FAN AND LIGHT Dear customers, Thank you for selecting the AUPU 3 in 1 Bathroom Heater. Please read all instructions before commencing
UB1 AIR CONDITIONING UNIT INSTALLATION INSTRUCTIONS
UB1 AIR CONDITIONING UNIT INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS: Carefully read these instructions before installing your new air-conditioner. AUSTRALIAN AUTOMOTIVE AIR AL00500054E 1 Table
Ceiling Mounted Folding Attic Ladders Installation Instructions
Ceiling Mounted Folding Attic Ladders Installation Instructions WARNING Before you start installing your new Louisville Ceiling Mounted Folding Attic Ladder, you must read and understand the following:
DYNA RIDER FOOTBOARD KIT
-J0 REV. 0-0-0 DYNA RIDER FOOTBOARD KIT GENERAL Kit Number 000 Models For model fitment information, see the P&A Retail Catalog or the Parts and Accessories section of www.harley-davidson.com (English
Installation Instructions
VentilAire IV Whole-House Fresh Air Supply System Installation Instructions 914228 Flat Roof Kit 914229 Sloped Roof Kit 5" x 11' Class I Insulated Flexible Duct Plastic Clamps (2) Metal Clamps (2) Ceiling
Arecont Vision H.264 Color or Day/Night SurroundVideo Series Installation Manual
0 P a g e H.264 Color or Day/Night SurroundVideo Installation Manual Inside the box: A. Arecont Vision SurroundVideo camera B. Mounting template C. RJ45 female to female coupler D. Hex key E. Security
Cooling system components, removing and installing
Engine BHW Cooling system components, removing and installing Page 1 / 24 19-1 Cooling system components, removing and installing Warning! When doing any repair work, especially in the engine compartment,
Isola Steel Gutters Strength and design for extreme climate!
Isola Steel Gutters Strength and design for extreme climate! Dry and healthy buildings Isola Steel Gutters Steeled against wind and weath The four seasons Wide temperature variations and highly variable
Volkswagen New Beetle 2.0 Liter 4-cyl General, Engine (Engine Code AEG) 17 Engine-Lubrication system (Page GR-17)
17 Engine-Lubrication system (Page GR-17) Lubrication system components, removing and installing Oil pan, removing and installing Oil pressure and oil pressure switch, checking Dynamic oil pressure warning
430 Power/Electronics Replacement
Replacing the main board WARNING Before proceeding, turn off the main power switch and unplug the power cord. Caution Make sure you are properly grounded with an ESD strap before continuing. The main printed
INSTALL INSTRUCTIONS KK-C-HVAC-1 HVAC UNIT 2003-2014 CHEVROLET/GMC VANS FOR
INSTALL INSTRUCTIONS KK-C-HVAC-1 HVAC UNIT 2003-2014 CHEVROLET/GMC VANS FOR (For NEW 2007 ALL WHITE KWIK-KITS ONLY) Warning do not attempt to install A/C units unless you are experienced with servicing
INSTRUCTIONS: LocknCharge Laptop Carts
INSTRUCTIONS: LocknCharge Laptop Carts www.lockncharge.com Extra Tools required: Hammer, Philips head screwdriver, medium adjustable spanner. (Allen key supplied) (Panel colours for illustration purposes
Toroidal Conductivity Sensor
Instruction Sheet PN 51A-/rev.C June 2012 Toroidal Conductivity Sensor For additional information, please visit our website at www.emersonprocess.com/rosemountanalytical.com SPECIFICATIONS Wetted Materials:
BUILD A CARPORT. 2 - Planning the carport. 3 - Designing the carport
BUILD A CARPORT You only need basic DIY and woodworking skills to build a carport. The most important part of the job is setting the supporting posts truly vertical - a job for which another pair of hands
Lunette 2 Series. Curved Fixed Frame Projection Screen. User s Guide
Lunette 2 Series Curved Fixed Frame Projection Screen User s Guide Important Safety and Warning Precautions Please follow these instructions carefully to ensure proper maintenance and safety with your
EH-20 20m antenna. By VE3RGW
EH-20 20m antenna By VE3RGW Equivalent circuit of EH-20 (prototype 2A) antenna system. Upper cylinder Lower cylinder Ground Counter pose Phasing coil Impedance transformer and tune circuit Tune coil Feed
OPL BASIC. Dosing System for Professional Laundry machines. Contents
OPL BASIC Dosing System for Professional Laundry machines Contents 1 Getting Started. Page 2 2 Installation. Page 4 3 Set Up & Operation. Page 8 4 Maintenance & Accessories. Page 10 5 Troubleshooting Page
HOME GYM. Model. Retain This Manual for Reference OWNER'S MANUAL. www.hyper-extension.com
NOTE: Please read all instructions carefully before using this product Table of Contents Safety Notice www.hyper-extension.com HOME GYM 50036 Hardware Identifier Assembly Instruction Parts List Warranty
Installation guide for the SafeLine type anchorage device. Tested in compliance with EN 795: 1996. No.: SE-...
Installation guide for the SafeLine type anchorage device Tested in compliance with EN 795: 1996 No.: SE-... Version: 09.10.2008 SE 67 Subject to technical alterations! Contents 1. General information
Cable Drum Installation
20 Cable Drum Installation COUNTERBALANCE None Shake the TorqueMaster spring tube gently to extend the winding shafts out about 5" on each side. For single spring applications, there will be no left hand
7. PRINCIPAL STEPS 8. POTENTIAL HAZARDS 9. RECOMMENDED CONTROLS
ACTIVITY HAZARD ANALYSIS (AHA) 1. Contract Number: 2. Contractor Name: 3. Date prepared: 4. Title/Activity Performed: FIXED SCAFFOLDING 5. Location: 6. Estimated Date of Completion: 7. PRINCIPAL STEPS
CHAPTER 65 TAIL ROTOR DRIVE SYSTEM. Section Title Page
CHAPTER 65 TAIL ROTOR DRIVE SYSTEM Section Title Page 65-00 Description........................................ 65.1 65-10 Tail Rotor Drive Fan Shaft.............................. 65.1 65-20 Tail Rotor
Table of Contents. www.hunterfan.com. What to Expect with. Preparation. Tools Needed. Wiring. Hanging the Fan. Blades. Motor Housing.
www.hunterfan.com Table of Contents What to Expect with Your Installation 30 inches Hanging the Fan Wiring 8 Maintenance, Operation & Cleaning Light Kit 13??? 14 1 9 Troubleshooting 11 5 Blades Motor Housing
2&3 SECTION LOFT LADDER
TWIST CATCH ASSEMBLY A4 A2 A1 A3 A7 A6 A5 2&3 SECTION LOFT LADDER Images feature the 3 section loft ladder, but the same instructions apply to both 2 & 3 section ladders Installation and Operating Instructions
EZ-Steer Assisted Steering System
EZ-Steer Assisted Steering System Installation Instructions Platform Kit P/N 53059-54 Case IH CVX 1135 CVX 1145 CVX 1155 CVX 1170 CVX 1190 CVX 1195 CVX 135 CVX 145 CVX 155 CVX 175 CVX 195 New Holland TVT
INSTALLATION INSTRUCTIONS
Rear Vision System Tailgate Handle Camera Mirror Display 2004-2014 Ford F-150 and 2008-2015 Ford Super Duty (Kit part numbers 9002-9521) Kit Contents: Mirror Tailgate Handle with camera and harness Interior
THE TRIMLINE 10' x 20' CANOPY
THE TRIMLINE 10' x 20' CANOPY Instructions for Assembly Please, assemble the TrimLine at home the first time, not at an event. Before beginning assembly of your TrimLine, please take time to review the
Thanks for choosing Toroidal. This file is developed to assist you in assembling and aligning Toroidal Dish.
Assembling Toroidal Thanks for choosing Toroidal. This file is developed to assist you in assembling and aligning Toroidal Dish. With Toroidal dish, you are aiming for more than 1 satellite and therefore
1. SAFETY RULES WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR PERSONAL INJURY, MOUNT FAN TO OUTLET BOX MARKED "ACCEPTABLE FOR FAN SUPPORT".
1 1. SAFETY RULES 1. To reduce the risk of electric shock, insure electricity has been turned off at the circuit breaker or fuse box before beginning. 2. All wiring must be in accordance with the National
AT&T. PARTNER Plus Door Phone. Installation and Operation Manual
AT&T PARTNER Plus Door Phone Installation and Operation Manual Copyright 1990 AT&T All Rights Reserved Printed in U.S.A. CIC# 999-500-317 OII722050-051 Issue 1 October 1990 PARTNER Plus Door Phone is a
SIMRAD SD10 Sailboat Drive
INSTALLATION MANUAL SIMRAD SD10 Sailboat Drive 20222683/A English Simrad SD10 Sailboat Drive About this document Rev. A First issue 2007 Navico AS. All rights reserved. No part of this work covered by
SUPERCHIPPER CASTING MAINTENANCE
INTRODUCTION By design, the Superchipper Rotor is clad in castings which wear during crushing. The castings wear at different rates depending on their location on the rotor, material feed rate, material
Guide for Installation and Maintenance of MacroAir (ME Series) High Volume Low Speed Fans
Guide for Installation and Maintenance of MacroAir (ME Series) High Volume Low Speed Fans Version 9.0 April 2014 1 Delivery: Upon receipt of fans, thoroughly inspect units for any damage sustained during
Slide the new steering column shaft through the steering column from the driver compartment.
Slide the new steering column shaft through the steering column from the driver compartment. Push the column shaft through the steering column until the machined end is out past the column lower bushing.
INSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS Accessory Application Publications No. AII 26327 2004 S2000 Issue Date OCT 2004 PARTS LIST Security System: P/N 08E51-S84-100 Attachment Kit: P/N 08E55-S2A-101 2 Remote controls
