IEC 1000-4-2 ESD Immunity and Transient Current Capability for the SP72X Series Protection Arrays



Similar documents
Automotive Electronics Council Component Technical Committee

SM712 Series 600W Asymmetrical TVS Diode Array

CAN Bus Transceivers Operate from 3.3V or 5V and Withstand ±60V Faults

Features. Symbol JEDEC TO-220AB

PS323. Precision, Single-Supply SPST Analog Switch. Features. Description. Block Diagram, Pin Configuration, and Truth Table. Applications PS323 PS323

AN Surging Ideas TVS Diode Application Note PROTECTION PRODUCTS. TRANSIENT IMMUNITY STANDARDS: IEC x

High-Speed, 5 V, 0.1 F CMOS RS-232 Driver/Receivers ADM202/ADM203

CAN bus ESD protection diode

4-bit binary full adder with fast carry CIN + (A1 + B1) + 2(A2 + B2) + 4(A3 + B3) + 8(A4 + B4) = = S1 + 2S2 + 4S3 + 8S4 + 16COUT

TS555. Low-power single CMOS timer. Description. Features. The TS555 is a single CMOS timer with very low consumption:

8-bit binary counter with output register; 3-state

+5 V Powered RS-232/RS-422 Transceiver AD7306

SM Series 400W TVS Diode Array

MM74HC4538 Dual Retriggerable Monostable Multivibrator

AP331A XX G - 7. Lead Free G : Green. Packaging (Note 2)

NUP2105L, SZNUP2105L. Dual Line CAN Bus Protector SOT 23 DUAL BIDIRECTIONAL VOLTAGE SUPPRESSOR 350 W PEAK POWER

Charged cable event. 1 Goal of the ongoing investigation. 2 Energy sources for the CDE. Content

Optocoupler, Phototransistor Output, Dual Channel, SOIC-8 Package

74HC238; 74HCT to-8 line decoder/demultiplexer

SG6516 PC Power Supply Supervisors

On/Off Controller with Debounce and

SMD version of BUK118-50DL

A p p l i c a t i o n N o t e

INTEGRATED CIRCUITS. NE558 Quad timer. Product data Supersedes data of 2001 Aug Feb 14

SDC15. TVS Diode Array for ESD Protection of 12V Data and Power Lines. PROTECTION PRODUCTS Description. Features. Mechanical Characteristics

Quad, Rail-to-Rail, Fault-Protected, SPST Analog Switches

NE555 SA555 - SE555. General-purpose single bipolar timers. Features. Description

74HC02; 74HCT General description. 2. Features and benefits. Ordering information. Quad 2-input NOR gate

NE555 SA555 - SE555. General-purpose single bipolar timers. Features. Description

PESDxU1UT series. 1. Product profile. Ultra low capacitance ESD protection diode in SOT23 package. 1.1 General description. 1.

Features. V PP IN V CC3 IN V CC5 IN (opt) EN0 EN1 MIC2562

PRTR5V0U2F; PRTR5V0U2K

MCR-VDC-UI-B-DC. Voltage Transducer for DC Voltages. INTERFACE Data Sheet _en_01. 1 Description

INTEGRATED CIRCUITS. 74LVC08A Quad 2-input AND gate. Product specification IC24 Data Handbook Jun 30

D-PAK version of BUK117-50DL

AMIS High-Speed 3.3 V Digital Interface CAN Transceiver

Theory of Operation. Figure 1 illustrates a fan motor circuit used in an automobile application. The TPIC kω AREF.

Following are definitions for major parameters to consider when selecting a power line polarity protection diode for an automotive application.

Cable Discharge Event

74HC138; 74HCT to-8 line decoder/demultiplexer; inverting

SELF-OSCILLATING HALF-BRIDGE DRIVER

DM74121 One-Shot with Clear and Complementary Outputs

RClamp0522PA RClamp0524PA

Advanced Monolithic Systems

74HC154; 74HCT to-16 line decoder/demultiplexer

74HC165; 74HCT bit parallel-in/serial out shift register

Spread-Spectrum Crystal Multiplier DS1080L. Features

How to design SMPS to Pass Common Mode Lightning Surge Test

Features. Applications

28V, 2A Buck Constant Current Switching Regulator for White LED

How To Make An Electric Static Discharge (Esd) Protection Diode

74HCU General description. 2. Features and benefits. 3. Ordering information. Hex unbuffered inverter

ICL V Powered, Dual RS-232 Transmitter/Receiver. Description. Features. Ordering Information. Applications. Functional Diagram.

DESCRIPTIO FEATURES APPLICATIO S TYPICAL APPLICATIO. LT1180A/LT1181A Low Power 5V RS232 Dual Driver/Receiver with 0.1µF Capacitors

N-channel enhancement mode TrenchMOS transistor

74HC393; 74HCT393. Dual 4-bit binary ripple counter

0.9V Boost Driver PR4403 for White LEDs in Solar Lamps

1.5A Very L.D.O Voltage Regulator LM29150/29151/29152

74HC107; 74HCT107. Dual JK flip-flop with reset; negative-edge trigger

74HC4040; 74HCT stage binary ripple counter

74HC377; 74HCT General description. 2. Features and benefits. 3. Ordering information

INTEGRATED CIRCUITS. 74F153 Dual 4-line to 1-line multiplexer. Product specification 1996 Jan 05 IC15 Data Handbook

RClamp0504P RailClamp Low Capacitance TVS Array

RClamp0514M RailClamp Low Capacitance TVS Diode Array PRELIMINARY Features

Discontinued Product For Reference Only

7-41 POWER FACTOR CORRECTION

DATA SHEET. TDA1543 Dual 16-bit DAC (economy version) (I 2 S input format) INTEGRATED CIRCUITS

Hex buffer with open-drain outputs

ESD9X3.3ST5G Series, SZESD9X3.3ST5G Series. Transient Voltage Suppressors Micro Packaged Diodes for ESD Protection

74HC2G02; 74HCT2G General description. 2. Features and benefits. 3. Ordering information. Dual 2-input NOR gate

3-to-8 line decoder, demultiplexer with address latches

CA723, CA723C. Voltage Regulators Adjustable from 2V to 37V at Output Currents Up to 150mA without External Pass Transistors. Features.

VN05N. High side smart power solid state relay PENTAWATT. Features. Description

Analog outputs. Public Document. VS10XX AppNote: Connecting analog outputs

3-input EXCLUSIVE-OR gate. The 74LVC1G386 provides a 3-input EXCLUSIVE-OR function.

IN1M101 Precision AC Brown-out Supervisor IC

uclamp3301h Low Voltage μclamp TM for ESD and CDE Protection PRELIMINARY Features

AAT3520/2/4 MicroPower Microprocessor Reset Circuit

MIC2940A/2941A. Features. General Description. Applications. Pin Configuration. 1.2A Low-Dropout Voltage Regulator

ESD Line Ultra-Large Bandwidth ESD Protection

RClamp0821P. Ultra-Low Capacitance 1-Line ESD protection. PROTECTION PRODUCTS - RailClamp Description. Features. Mechanical Characteristics

STCS2A. 2 A max constant current LED driver. Features. Applications. Description

RFG70N06, RFP70N06, RF1S70N06, RF1S70N06SM

38 SERIES. Relay interface modules A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.

74HC175; 74HCT175. Quad D-type flip-flop with reset; positive-edge trigger

Tone Ringer SL2410 LOGIC DIAGRAM PIN ASSIGNMENT SLS

AN1826 APPLICATION NOTE TRANSIENT PROTECTION SOLUTIONS: Transil diode versus Varistor

Features. Applications. Truth Table. Close

74HC123; 74HCT123. Dual retriggerable monostable multivibrator with reset

Low-power configurable multiple function gate

PINNING - TO220AB PIN CONFIGURATION SYMBOL

BUZ11. 30A, 50V, Ohm, N-Channel Power MOSFET. Features. [ /Title (BUZ1 1) /Subject. (30A, 50V, Ohm, N- Channel. Ordering Information

Features INVERTING. 0.6mA NONINVERTING INVERTING. 0.6mA NONINVERTING

LIN-bus ESD protection diode

MADR TR. Quad Driver for GaAs FET or PIN Diode Switches and Attenuators. Functional Schematic. Features. Description. Pin Configuration 2

SG2525A SG3525A REGULATING PULSE WIDTH MODULATORS

ESDLIN1524BJ. Transil, transient voltage surge suppressor diode for ESD protection. Features. Description SOD323

AAT4280 Slew Rate Controlled Load Switch

Inrush Current. Although the concepts stated are universal, this application note was written specifically for Interpoint products.

Transcription:

IEC 00-4-2 ESD Immunity and Transient Current Capability for the SP72X Series Protection Arrays Application Note July 1999 AN9612.2 Author: Wayne Austin The SP720, SP721, SP723, and SP724 are protection ICs with an array of SCR/Diode bipolar structures for ESD and over-voltage protection of sensitive input circuits. They have 2 protection SCR/Diode device structures per input. The SP720 is supplied in 16 lead DIP and SOIC packages and has a total of 14 available inputs that can be used to protect up to 14 external signal or bus lines. The SP721 and SP723 are 8 pin devices with the same protection structures and have the same package options. The SP723 has dual cell structures for each input to achieve substantially improved ESD and Transient Current capability. The SP724 is a four section array in a 6-lead SOT-23. Its cell structure has been redesigned for improved ESD immunity. The SCR structures are designed for fast triggering at a threshold of one +V BE diode threshold above V+ (positive supply terminal) or a -V BE diode threshold below (negative or ground). A clamp to V+ is activated at each protection input if a transient pulse causes the input to be increased to a voltage level greater than one V BE above V+. A similar clamp to is activated if a negative pulse, one V BE less than, is applied to an input. Various standards for testing the ESD capability of semiconductor products have been developed in recent years. Each standard was generated with regard to a specific need related to the electromagnetic compatibility of the system environment. They include the Human Body Model (HBM), Machine Model (MM) and the Charged Device Model (CDM). Each such standard relates to the nature of electrostatic discharge generated within a system application and the potential for damage to the IC. For these better known standards, the actual results for ESD tests on the SP720 and SP721 are as follows: 1. Human Body Model using a modified version of the MIL-STD-883, Method 3015.7; with V+ and grounded and ESD discharge applied to each individual pin - Passed all test levels from ±9kV to ±16kV (1kV steps). 2. Human Body Model using the MIL-STD-883, Method 3015.7 (with only grounded) and ESD discharge applied to each individual pin - Passed all test levels to ±6kV, failed ±7kV (1kV steps). 3. Machine Model using EIAJ IC121 (R D = 0Ω); discharge applied to pins with all others grounded - Passed all test levels to ±1kV, failed ±1.2kV; (200V steps). 4. Human Body Model using the IEC 00-4-2 standard with V+ and grounded and ESD discharge applied to each individual pin - Passed test Level 2. The SP723 capability surpasses those of the SP720 and SP721 and meets the Level 4 requirements of the IEC 00-4-2 HBM standard. IEC 00-4-2 ESD Standard One of the more recent standards to be developed is the IEC (International Electrotechnical Commission) 00-4-2. The IEC document relates to the HBM but encompasses a range of normal environmental conditions. Testing for ESD immunity is more broadly defined to include a device, equipment or system. Both direct contact and air discharge methods of testing are used with four discrete steps in the severity level ranging up to 8kV and 15kV respectively. In its simplest form, the Figure 1 test circuit provides for a means of charging the 150pF capacitor, R C through the charge switch and discharging ESD pulses through the 330Ω resistor, R D and discharge switch to the Equipment or Device Under Test (EUT, DUT) under test. ±DC HV E C CHARGE SWITCH R C 50-0MΩ R D 330Ω C D 150pF DISCHARGE SWITCH EUT OR DUT FIGURE 1. SIMPLIFIED IEC 00-4-2 ESD TEST ENERGY SOURCE The test equipment for the IEC 00-4-2 standard is constructed to provide the equivalent of an actual human body ESD discharge and has the waveform shown in Figure 2. CURRENT 0% 90% I AT 30ns I AT 60ns % I PEAK t R = 0.7 TO 1ns 30ns 60ns FIGURE 2. TYPICAL WAVEFORM OF THE OUTPUT CURRENT OF THE HBM ESD GENERATOR AS SPECIFIED THE IEC 00-4-2 STANDARD TIME -61 1-800-999-9445 or 1-847-824-1188 Copyright Littelfuse, Inc. 1999

The IEC 00-4-2 severity level of testing is defined by stepping the DC High Voltage rather than changing the R C discharge components. The severity levels are separately defined for plus and minus polarity of direct contact discharge (preferred) and air discharge as shown in Table 1. Other voltage levels may be specified for the IEC 00-4-2 test equipment and conditions. LEVEL TABLE 1. IEC 00-4-2 SEVERITY TEST VOLTAGE, kv CONTACT DISCHARGE TEST VOLTAGE, kv AIR DISCHARGE 1 2 2 2 4 4 3 6 8 4 8 15 As a subsystem component, the SP720, SP721 and SP723 may be used at the PC board or module interface for protection. In a typical application, the ESD Protection Arrays would be used to protect more sensitive circuits at the line interface or input terminals to a board or module. Normally, the circuit configuration of Figure 3 is the recommended way to protect ESD sensitive inputs which relates to the IEC 00-4-2 definitions for equipment, systems, subsystems and peripherals. To determine the capability of ESD Protection Arrays to protect an active circuit, the ESD Protection Arrays were tested as single devices. Following the conditions of the IEC 00-4-2 specification, both direct contact and air discharge ESD tests were performed. general, the SP720 and SP721 have the capability to withstand Level 2 direct contact ESD discharge for the test conditions defined in the IEC 00-4-2 standard. In Table 2C, all pins on six SP720 and four SP721 devices were tested for ESD Air Discharge Capability and passed without failures up to 16.5kV. This is better than the IEC 00-4-2 standard to Level 4 severity requirements. The SP723 was tested using the same conditions given for the SP720 and SP721. TABLE 2A. SP720 TESTS TO IEC 00-4-2 USG DIRECT CONTACT (+) DIRECT CONTACT TO EACH P V CC = 0V, 5 Devices Tested (-) DIRECT CONTACT TO EACH P 1, 2, 3 All Pass All Pass 4 All Pass 2 Fail V CC = 5.5V, 20 Devices Tested 1, 2 All Pass All Pass 3 All Pass 8 Fail 4 All Pass Remaining 12 Fail V CC = 15V, 6 Devices Tested 1, 2 All Pass All Pass 3 All Pass 3 Fail 4 All Pass Remaining 3 Fail TABLE 2B. SP721 TESTS TO IEC 00-4-2 USG DIRECT CONTACT SYSTEM SUBCIRCUIT OR MODULE V CC OR V+ V+ SUPPLY (+) DIRECT CONTACT TO EACH P V CC = 5.5V, 20 Devices Tested (-) DIRECT CONTACT TO EACH P SIGNAL PUT ACTIVE CIRCUIT 1, 2 All Pass All Pass 3 All Pass 8 Fail 4 All Pass Remaining 12 Fail SP720 1 OF 14 CELLS IEC 00-4-2 ESD Test Evaluation GND OR SUPPLY FIGURE 3. ONE PROTECTION CELL OF THE SP720 SHOWN AS PROTECTION TERFACE ON A CIRCUIT ESD Direct Contact and Air Discharge Capability For = Ground, V+ = V CC (varied) and T A = 25 o C, single pulse ESD testing was done at each pin of the SP720 and SP721. The results are shown in Tables 2A and 2B. In TABLE 2C. SP720 AND SP721 TESTS TO IEC 00-4-2 USG AIR DISCHARGE (+) AIR DISCHARGE TO EACH P V CC = 15V, 6 SP720, 4 SP721 Devices Tested (-) AIR DISCHARGE TO EACH P 1 All Pass All Pass 2 All Pass All Pass 3 All Pass All Pass 4 All Pass All Pass The SP723 was tested using the same conditions given for the SP720 and SP721. -62

Table 2D shows the results for direct contact discharge and Table 2E show the SP723 capability for air discharge. Where each SP723 input has a dual input structure equal to the SP720 and SP721 which pass Level 4 air discharge conditions, the capability of the SP723 will exceed that by a wide margin but testing was not done due to test equipment limitations. TABLE 2D. SP723 TESTS TO IEC 00-4-2 USG DIRECT DISCHARGE (+) DIRECT DISCHARGE TO EACH P V CC = 15V, 8 Devices Tested (-) DIRECT DISCHARGE TO EACH P 1, 2, 3, 4 All Pass All Pass TABLE 2E. SP723 IEC 00-4-2 LEVEL CAPABILITY USG AIR DISCHARGE (+) AIR DISCHARGE TO EACH P Results based on SP720, SP721 Data (-) AIR DISCHARGE TO EACH P 1, 2, 3, 4 All Pass All Pass Measured Peak Current in Direct Discharge ESD Testing Verification for peak current calibration during testing for the ESD direct contact discharge was done for ESD Tests in Table 2. The measured peak currents occurs in 1ns and the 50% discharge occurs in 30ns as shown in Figure 2. The verified results as shown below in Table 3. These test levels conform to the IEC 00-4-2 standard requirement for peak current to be within ±%. TABLE 3. SP720 TESTS TO IEC 00-4-2 LEVEL Level 1 Level 2 Level 3 Level 4 Level 4 plus 1kV VOLTAGE +2kV -2kV +4kV -4kV +6kV -6kV +8kV -8kV +9kV -9kV PEAK CURRENT 0.7ns TO 1ns RISE TIME, MEASURED +7.5A -8A +15A -16A +22A -22A PEAK CURRENT 0.7ns TO 1ns RISE TIME, STANDARD ±7.5A ±15A ±22.5A - ±30A at 8kV +34A -34A The 9kV level was measured (instead of 8kV) to verify the extended range level of performance, which is the limit of the test equipment. A linear increase beyond the specified standard of 30A at 8kV would be equivalent to 33.75A at 9kV. Multiple Pin Input ESD Test Evaluation While the SP723 would be a preferred choice to extend the range of ESD protection, by using 2 or more input pins of the SP720 or SP721 also increases the range of ESD immunity. For example, by connecting adjacent SP720 pins in parallel using the dual pin combinations 1+2, 3+4, 5+6, 7+9, +11, 12+13 and 14+15, the IEC 00-4-2 voltage capability is increased to better than ±9kV. (The ±9kV level is an equipment limited maximum voltage.) Peak Current Capability While the primary purpose of the SP720, SP721 and SP723 are for ESD protection, there is an implied need for surge current immunity in some circuit applications. As noted by the high peak currents recorded during ESD testing (Table 3), it can be expected that peak transient current capability rises sharply as the width of the current pulse narrows. Destructive testing was done to fully evaluate device ability to withstand a wide range of peak current pulses vs time. The circuit used to generate current pulses is shown in Figure 4. The test circuit of Figure 4 is shown with a positive pulse input as it would apply to the SP720. For a negative pulse input, the (-) current pulse input goes to an SP720 input pin and the (+) current pulse input goes to the SP720 pin. The V+ to supply of the SP720 must be allowed to float. (i.e., It is not tied to the ground reference of the current pulse generator.) + V X - R 1 VOLTAGE PROBE R 1 ~ Ω TYPICAL V X ADJ. V/A TYPICAL C1 ~ 0µF (+) VARIABLE TIME DURATION CURRENT PULSE GENERATOR CURRENT SENSE 1 2 3 4 5 6 7 8 V+ 16 15 SP720 14 13 12 11 9 FIGURE 4. TYPICAL SP720 PEAK CURRENT TEST CIRCUIT WITH A VARIABLE PULSE WIDTH PUT Figure 5 shows a connected curve for each point of overstress as defined by increased leakage in the SP720 to well over the published limits of the data sheet. Using the similar connection test circuit configuration, the SP723 capability is shown on the same curve. The SP723 curve for a 15V supply shows a capability of A peak current for the µs pulse and 4A peak current for the 1ms pulse. The complete curve for a single pulse time up to 1 second is shown. (-) C1 + - -63

9 PEAK CURRENT (A) 8 7 6 5 4 CAUTION: SAFE OPERATG CONDITIONS LIMIT THE MAXIMUM PEAK CURRENT FOR A GIVEN PULSE WIDTH TO BE NO GREATER THAN 75% OF THE VALUES SHOWN ON EACH CURVE. SP720 CURVES SP723 CURVE 3 2 0V 5V 30V 15V 15V 1 0 0.001 0.01 0.1 1 PULSE WIDTH TIME (ms) V+ TO SUPPLY 0 00 FIGURE 5. SP720 AND SP723 TYPICAL SGLE PULSE PEAK CURRENT CURVES SHOWG THE MEASURED POT OF OVER AMPERES vs PULSE WIDTH TIME MILLISECONDS (T A = 25 o C) 12 11 9 T A = 25 o C CAUTION: SAFE OPERATG CONDITIONS LIMIT THE MAXIMUM PEAK CURRENT FOR A GIVEN PULSE WIDTH TO BE NO GREATER THAN 75% OF THE VALUES SHOWN ON EACH CURVE. V+ TO SUPPLY = 15V PEAK CURRENT (A) 8 7 6 5 T A = 25 o C SP721 CURVES SP723 CURVE 4 3 T A = 5 o C 2 1 0 0.001 0.01 0.1 1 PULSE WIDTH TIME (ms) 0 00 FIGURE 6. SP721 AND SP723 TYPICAL SGLE PULSE PEAK CURRENT CURVES SHOWG THE MEASURED POT OF OVER AMPERES vs PULSE WIDTH TIME MILLISECONDS -64

Figure 6 shows the single pulse peak current capability of the SP721 for 5 o C ambient temperature conditions. The SP721 is an 8 pin package version of the SP720 but is otherwise has the same short pulse width peak current capability. The SP721 curve for 25 o C is shown for comparison. The reduction in maximum peak current attributed to an increase of ambient temperature from 25 o C to 5 o C is typically %. The overall effect of increased chip temperature, whether by ambient temperature increase or current induced dissipation, is to reduce the peak current ratings. The maximum rated operating ambient temperature for both the SP720 and SP721 is 5 o C. Multiple Pin Input Peak Current Test Evaluation Uniformity of design and processing in the SP720 provides the capability to use multiple pins for added input protection. The very short pulse test capability for the dual pins is approximately twice the peak current for a single pin. However, for the 0ms to 00ms pulses, the dual pin peak current stress capability decreases, approaching that of the single pin level. The longer pulse condition is limited by the heat capacity of the chip and eventually forces a more rapid increase in the chip temperature. Other Transient Conditions Conducted Susceptibility to Transients Conducted Susceptibility to Transients is a test defined by the automotive SAE J1113 standard. The waveform used to test devices simulates the transient caused by a parallel or series inductive load when the supply current is switched off. Figure 7 illustrates the pulse waveforms generated by a Schaffner 5000 Transient Pulse Test Generator used to test the SP720. For the purposes of this test, Test Pulse 1 and 2 were applied while the V+ and voltage to the SP720 was at ground. Destructive level testing at room temperature was conducted with a single 200µs pulse while applying the transient signal to each input pin. It should be noted that the width for the 200µs pulse is defined for the % turn-on levels. The sourced voltage from the generator, V S, was varied while the peak current was monitored. Test Results for Single Pin Testing Up to consecutive pulses were applied at a 5 second rate to verify the transient capability of each input. It was determined that levels of +5.5A and -8A were sufficient to damage the inputs. Peak current levels of +5A (+6.5V) and V t 2 V+ (GND) % t 3 % of PEAK; REF. 0V t V S 90% V 90% S S T T t 1 t 1 SP720 TEST CONDITIONS: V+ = = 0V V S = TRANSIENT PEAK VOLTAGE, VARIED R I = Ω TRANSIENT SOURCE IMPEDANCE t = 200µs S = 80V/µs t 1 = 0.5s TO 5s t 2 = 0.2 t 3 = TIME BETWEEN SUPPLY SWITCH OFF AND PULSE (TYPICALLY 0µs) V S % of PEAK; REF. 0V V+ (GND) % t t 2 FIGURE 7. TRANSIENT DUCTIVE vs TIME WAVEFORMS APPLIED TO THE SP720 PUT PS. THE TOP WAVEFORM IS APPLIED FOR THE A DUT PARALLEL WITH AN DUCTIVE LOAD AND THE BOTTOM WAVEFORM IS APPLIED FOR SERIES CONNECTED POWER TURN-OFF (REF. SAE J1113 STANDARD) -65

-7A (-6V) were found to be a marginal safe level for single pulses applied to the inputs. Test Results for Double Pin Testing It was determined that paralleling input pins will permit twice the single pin current capability. Sustained testing at a 2Hz rate was done after paralleling pins 1+2, 3+5 and 6+7. The results for a +A, 200µs positive transient current pulse were: PS PARALLEL 1+2 3+5 6+7 Device 2 Failed at - 3500 5600 Pulses Device 3 Failed at 1150 230 340 Pulses Sustained safe peak current levels should be no more than 70% of the point of overstress. At higher ambient temperature up to the maximum rated conditions of 5 o C, the allowed maximum peak current should be further reduced by at least %. SP720 and SP723 Surge Immunity Test Capability per the 8/20µs Short Circuit Conditions of IEC 00-4-5 While the IEC 00-4-5 is a standard that generally implies higher levels of power than recommended for the SP720 and SP723, testing was done to determine the comparable level of capability. The test circuit conditions for an 8/20µs short circuit current pulse are shown in Figures 8A and 8B. It should be noted that the 8/20µs pulse is defined as 20µs wide from a delayed turn-on to a 50% turn-off. SP720 Test Results: The short circuit current marginal point of overstress at room temperature was determined to be: For + Positive Surge Polarity (upper unit): V CC = 6V Typically greater than 5A V CC = 15V Typically greater than 4.8A V CC = 35V Typically greater than 4.2A For - Negative Surge Polarity (lower unit): V CC = 15V Typically greater than 5.8A V CC = 35V Typically greater than 5.8A As previously noted, paralleling pins on the SP720 will increase the current capability to approximately twice that of a single pin. SP723 Test Results: The short circuit current marginal point of overstress at room temperature was determined to be: For + Positive Surge Polarity (upper unit): V CC = 6V Typically greater than 9.8A V CC = 15V Typically greater than 9.5A V CC = 35V Typically greater than 9A For - Negative Surge Polarity (lower unit): V CC = 6V Typically greater than 11.7A V CC = 15V Typically greater than 11.1A V CC = 35V Typically greater than.6a As previously noted, sustained safe peak current levels should be no more than 70% of the point of overstress. At higher ambient temperature up to the maximum rated conditions of 5 o C, the allowed maximum peak current should be further reduced by at least %. R C CHARGG RESISTOR C C ENERGY STORAGE CAPACITOR R S1, R S2 PULSE SHAPG RESISTORS L R RISETIME SHAPG DUCTOR CURRENT HIGH VOLTAGE R C R M L R EUT + - C C OR RS1 R S2 DUT FIGURE 8A. CIRCUIT DIAGRAM OF GENERATOR FOR 8/20µs PULSE WAVEFORM 1.0 0.9 0.5 0.1 0.0 t t 1 FRONT TIME: t 1 = 1.25xt = 8µs ±20% TIME TO HALF VALUE: t 2 = 20µs ±20% t 2 TIME FIGURE 8B. WAVE SHAPE FOR 8/20µs SHORT CIRCUIT CURRENT PULSE PER IEC 60-1 <30% -66