Venture Lighting Bright Ideas Bold Innovations



Similar documents
Kolorlux. GE Lighting DATA SHEET

Multi-Vapor Metal Halide Lamps

Rated Lumen [lm] Nominal. Volts [V] [lm]

Petrol Station Canopies

SYLVANIA METALARC Pulse Start Metal Halide Lamps

ConstantColor CMH MR16

GE ConstantColor CMH Precise MR16 20 & 35W

Metal Halide Pulse Start vs. Probe Start. By Dick Erdmann GE Specification Engineer

Applications. Architectural

PPL Electric Utilities Energy Efficiency and Conservation Program

LIGHTING and LIGHTING SYSTEMS

T5 LongLast. GE Lighting DATA SHEET

Session 15 Lighting Fundamentals

Biax S and S/E. Compact Fluorescent Lamps Non-Integrated 5W, 7W, 9W and 11W. GE Lighting DATA SHEET. Product information. Features.

DuroSite TM High Bay Lighting

induction lighting toll free: tel: fax:

T5 Watt-Miser Linear Fluorescent lamps

IPS HIGH-BAY / LOW-BAY LIGHTING

(Refer Slide Time: 00:01:43 min)

GE Lighting. Spectrum Catalogue 2013/14

Leaders In Industrial LED Lighting Solutions. CleanLED Highbay/Lowbay. Energy Efficient LED Lighting Solutions For Industry

Lumination LED Luminaires

Guide to new, energy-efficient lighting technologies for your business

HANDY INFORMAL LIGHTING GLOSSARY

C2D LowBay: All the power, none of the bulk. C2D Advantage

T5 Fluorescent Lamps SYLVANIA PENTRON & PENTRON HO

High Pressure Mercury

Property Risk Management HIGH INTENSITY DISCHARGE ELECTRICAL LIGHTING

CHAPTER 10: APPLIANCES AND LIGHTING

Retrofit HID High Bay Fixtures to Long Life High Efficiency LED

Why Philips LEDtube? LED Lamps EMEA February February 2015_BG LS & E LEDlamps

Biax T/E. Triple Biax Compact Fluorescent Lamps Non-Integrated 13W, 18W, 26W, 32W and 42W. GE Lighting. Product description.

Lumination LED Luminaires

Do not touch glass part of the bulb with your hands during installation.

Halogen Lamps. Lamp Construction

Lumination LED Luminaires

5YR. Advanced LED lighting. High performance industrial lighting. 50% energy against traditional fittings Up to 75% energy saving with sensing

LicensedArchitect. $6.00 Volume 15, No. 3 Fall Association of Licensed Architects

The right. LEDtube. every time. LEDlamps

Photosynthesis Light for Horticulture

Twin EL Wall luminaires for halogen lamps or ceramic metal halide lamps

Nightscape High performance floodlights and spotlights for discharge lamps

LED DOWNLIGHT ONE 50XX SERIES

Nashville Electric Service

Technical Information. Lamp Data - Light tubes

OPEN OFFICE T8 HP FLUORESCENT HIGH PERFORMANCE LENSED

GE Lighting Solutions. Albeo LED Luminaire. Modular High & Low Bay Lighting. (ABHX - Series) imagination at work

Cree Edge and LEDway by Cree Compared to Induction Lamp Luminaires

In the following Temperature Profile Data Charts when a T code is used, this chart explains the temperature maximum (in degrees Celsius).

LED Tubular Lamp / Kit Guide

A Guide to Energy Efficient and Cost Effective Lighting

LED Retro Fit the next generation in energy efficiency. Converting existing 12v systems to LED

Energy efficient lighting for your home find out more.

9W T8 LED TUBE 2FT GENERAL INFORMATION

INDUSTRIAL & SPORTS LIGHTING

A Philips Ledalite Chopstick LED Semi-Indirect Luminaire

ENERGY EFFICIENT LIGHTING

General Lighting Recommendations

Industrial Solutions. Made to order. Imagine lighting as versatile as the industries it serves.

Middle Power LM231A LM231B LM561A LM561B LM362A

Features. High Brightness LED Light source

GE Lighting. Albeo LED Luminaire. Modular High & Low Bay Lighting. (ABH2 - Series) imagination at work

Codes and Standards Enhancement (CASE) Initiative For PY2008: Title 20 Standards Development

The most sustainable lighting solution. QL 85W Induction Lighting System

Universal Fibre Optics L E D L I G H T S O U R C E S

Small Commercial Business Energy Audits. Recognizing and addressing the special requirements of the small business market segment.

SkyBay LED Low & High Bay 1

GE Lighting. Lighting the future. Your guide to changing to energy efficient lamps

Frequently Asked Questions About OHP Lamps

Product specifications

LED HIGHBAY COMMERCIAL & INDUSTRIAL DESIGNED MANUFACTURED AND WARRANTED IN AUSTRALIA

Flexible LED system approach

CHM-27 COB Arrays White LED

PRODUCTS IN FOCUS SPECIALIST PRODUCTS AND TOP SELLERS FOR INDIVIDUAL LIGHTING SOLUTIONS ISSUE 1 MODILITE COLORLITE TOPFLOOD REFLEKTO CLEAR

KATO. LED Lighting High Bay und Low Bay

Indoor/Outdoor Sign Lighters Energy-efficient, modular fixtures for commercial signage and retail displays

Linear Fluorescent Lamp Guide

Distributed Array LED Modules High efficacy solutions for diffuse ambient lighting

Energy-efficient lighting

Nightspot A2 Floodlights for LEDs and high pressure discharge lamps

The new generation of energy saving tube lighting

LED. Light source of the future. Ten things you should know about LED

Why Philips LEDtube? Leander Bloot Product marketing LEDtubes LED Lamps EMEA January January 2014_BG LS & E LEDlamps

MASTER LEDluster. MASTER LEDluster D 4-25W E14. Product data

LG LED Road & Street Lighting

Contrast 2 LED. Performance Compactness Complete flexibility NEW

Invue ECM/EMM EPIC MEDIUM W

More light where it is needed.

denver elite bollard Patent Pending REGISTERED EUROPEAN DESIGN

`ÉàÉÜvçvÄxÅxàtÄAvÉÅ \ÇvA 5490 S.W. 42nd St. Davie, FL Toll free Local

Better Vision with LED lights

1247 Norwood Avenue, Itasca, IL (800)

Discontinued. LUXEON V Portable. power light source. Introduction

ENERGY EFFICIENCY IN STREET LIGHTING

C W COB Series

LED Module SPECIFICATION. LED Module for Modular Platform Series. LED Platform Module with Fin

Transcription:

Venture Lighting Bright Ideas Bold Innovations NEW! Ceramic Master-PLUS lamp range see Pages 0 - European HID Lighting Systems Catalogue

Who is Venture? - An Innovator and Worldwide Manufacturer Venture Lighting, the fastest growing metal halide lighting company in the world, is the only one concentrated on this technology. Since 98, we ve created a constant stream of new systems for our customers. Our range of optimized lamps and control gear, including the revolutionary Uni-Form pulse start system, has grown to encompass lamp wattages 5 to,000. This unique focus offers you peak performance lighting solutions. Our North American headquarters includes a state-of-the-art development and new products manufacturing center to support our leadership in originating new systems. The company is part of Advanced Lighting Technologies Inc. (ADLT) Our sister companies feature complementary capabilities: APL Engineered Materials (APL) is a strategic supplier of halides, amalgams and other components to the lighting industry. Deposition Sciences, Inc. (DSI) is a leader in sophisticated thin film coatings and deposition systems to the lighting industry. Global Perspective Venture maintains a worldwide network of low cost, lean manufacturing facilities. Quality is sustained through control systems constructed to meet ISO 900 standards. Along with our premier lamp facility in North America. Our Indian facility, the largest metal halide plant in the Pacific Rim, produces both lamps and control gear. +() 085-0 Fax +() 085-0077 www.venturelightingeurope.com E-mail: sales@venturelighting.co.uk

Contents Venture Lighting Europe Simply a Better Metal Halide Lamp 5 The Secret is in the Shape 6 Additional Protection 7 White-Lux HPS Replacement Lamps 8 Open Rated Horizontal Tubular Lamps 9 White-Lux Plus 0 White-Lux Plus Energy Saving Lamps Uniform Pulse Start Energy Saving Uniform Pulse Start High Performance Tubular Lamps 5 Euro Metal Halide 6 Euro Metal Halide 7 Natural White Full Spectrum 8 Natural White 9 New Ceramic Master-PLUS Metal Halide 0 New Ceramic Master-PLUS Metal Halide CWA High Wattage Lamps Double Ended and G Designer Colour 5 Aquatic and Special Purpose Lamps 6 Description Codes and Ordering Information 7 Ventronic Dimmable HID Control Gear 8 Ventronic POD Ventronic Low Wattage Ventronic HID Control Gear Venture Parmar Ballasts The P-Range HID Ballasts 6 The MCi Series Ignitor 7 Control Gear for HPS, MH & Ceramic MH Lamps 5W 50W & 70W 8 Control Gear for HPS, MH & Ceramic MH Lamps 00W 50W &00W 0 Control Gear for HPS, MH & Ceramic MH Lamps 50W Control Gear for HPS, MH & Ceramic MH Lamps 00W Control Gear for MH &Ceramic MH Lamps 50W 00W & 50W Control Gear for HPS, MH Lamps 600W 000W 500W & 000W Control Gear for Mercury Lamps / SOX Lamps 50W - 000W Mercury Lamps 5W - 5W SOX Lamps 5 Control Gear for CWA, MH, Other Lamps, Lamp Detecting Device & Auto Transformers 6 High Power Factor Conversion Kits 7 Ignitors 8 Capacitors 9 Circuit Diagrams 5 Glossary of Terms 5 Warranty 55 +() 085-0 Fax +() 085-0077 www.venturelightingeurope.com E-mail: sales@venturelighting.co.uk

Venture Lighting - Europe Our modern European Headquarters are based in Rickmansworth, Hertfordshire just two miles away from the M5, 0 minutes from Heathrow and close to Rickmansworth station with its links to central London. That's why we strive to offer our customers, large and small, a level of service unequalled in the industry. Our dedicated UK customer service team supported by our experienced technical department is always there to provide expert product advice and to help you with all your Metal Halide requirements. The offices house our sales and marketing operations, administration offices, as well as our customer service teams for the UK and our European Distribution network. We also pride ourselves on excellent stock availability and a next day delivery service that's the envy of the industry. Our new purpose-built warehousing and distribution facilities have been designed to improve our service even more. Our new Technical and Distribution Centre located in Castle Donington, Derbyshire offers full technical support on all our products In fact our emphasis on quality service is just one further reason why more and more installers, specifiers and OEMs are switching to Venture Lighting for all their Metal Halide requirements. We believe that the best products in Metal Halide today should be complemented by the very best service and support. As a Venture Lighting customer, you're assured the very best technology combined with the very highest level of service. In short, everything you'd expect from a global leader in the industry. +() 085-0 Fax +() 085-0077 www.venturelightingeurope.com E-mail: sales@venturelighting.co.uk

Simply a Better Metal Halide Lamp Quality Exclusive formed body arc tube for consistency beyond ceramic metal halide Patented stronger weldless mount construction to minimise delivery and handling breakages 'Tipless' arc tube improves performance for maximum colour and light output uniformity Performance Longer lamp life Enhanced lumen maintenance Excellent system colour uniformity Hot restart in less than half the time of standard pinch body metal halide systems 50% faster warm-up Safety Shrouded 'open-rated' lamps to provide protection for luminaires without lenses UV Shield - blocks up to 80% UV, 50% more than most UV-reducing lamps Reduces UV damage to merchandise and signage Additional GlassGuard coating available for additional protection against breakage Selection Venture's Uni-Form pulse start series of lamps has the greatest selection of lumen packages: 50W to 50W Most comprehensive range of open-rated products available in the industry CCY Color Uniformity - MacAdam Ellipses.0.0.06.008 0 -.008 -.06 -.0 -.0 -.0 -.0 -.06 -.008 0.008.06.0.0 Standard MH 0-step ellipse CCX Ceramic MH 6-step ellipse Uni-Form MH -step ellipse Exclusive tipless arc tube - totally uniform shape further improves performance for maximum colour and light output uniformity Unique formed body arc tube - shaped to follow the curve of the arc stream to deliver superior lamp efficacy Safety shroud with UV Shield - blocks up to 80% UV, 50% more than most UV-reducing lamps to prevent Polycarbonate fixtures from yellowing Patented stronger weldless mount construction - no welds mean less breakage during shipping and handling 5Lamps +() 085-0 Fax +() 085-0077 www.venturelightingeurope.com E-mail: sales@venturelighting.co.uk

The Secret is in the Shape Lamps Venture s Unique Formed Body Arc Tube Technology Superior colour uniformity, less deviation from lamp to lamp - Consistency beyond ceramic metal halide Highest lamp efficacy Patented stronger weldless arc tube mounting technology Higher maintained lumens, longer lamp life Hot restart in less than half the time of regular metal halide 50% faster warm-up The Tipless Difference Unique formed body arc tube - shaped to follow the curve of the arc stream delivers superior lamp efficacy Exclusive tipless arc tube - Totally uniform shape further improves performance for maximum colour and light output uniformity 6 +() 085-0 Fax +() 085-0077 www.venturelightingeurope.com E-mail: sales@venturelighting.co.uk

Additional Protection for your Metal Halide Lamps Open Luminaire Rated HIPE lamps Incorporating an internal shroud to prevent the outer envelope from shattering in the unlikely event of a lamp malfunction Arc tube surrounded by an internal shroud Continuous operation no shut off required Eliminates the need for a luminaire lens, to provide more light UV Shield the solution to polycarbonate yellowing Incorporating an impregnated quartz shroud to absorb ultraviolet light Prevents 'yellowing' of polycarbonate lenses Blocks up to 80% of damaging UV Light With UV Shield Ruptured arc tube contained in the intact outer jacket of a Venture HIPE open rated lamp Can extend the life of the fitting lens up to 0 times Without UV Shield GLASS GUARD * fragment retention technology Prevents a lamp from shattering if dropped or mishandled Broken and shattered lamps are completely retained within the lamps additional protective coating. Completely prevents glass contamination or injury from a broken lamp Protects personnel, products and profits Available for any elliptical lamp operating vertically * GlassGuard is a registered trademark of Fotolec Technologies plc 7Lamps +() 085-0 Fax +() 085-0077 www.venturelightingeurope.com E-mail: sales@venturelighting.co.uk

White-Lux - HPS Replacement Lamps Lamps It s quick and simple to get rid of old, high-pressure sodium lighting with White-Lux Plus Metal Halide lamps from Venture Lighting. White-Lux Plus lamps can operate directly from existing HPS control gear. Even difficult 70W HPS lamps with internal starters can be directly replaced, using a simple conversion kit. So why put up with murky yellow-tinged sodium lighting when it s never been easier or more cost effective to switch and enjoy the clean, fresh and natural white light of metal halide lamp technology! From the world leaders in metal halide technology Unique Venture Uni-Form formed body arc tube Faster warm-up and hot restart Increased efficiency Long life up to 0,000 hours Better lamp-to-lamp consistency A full range of ratings from 50 to 00 watts A choice of tubular and elliptical designs Clear or coated outer jackets For use in open or enclosed fittings No thermal cut-out ballasts required Environmentally friendly UV shields available for fittings with poly-carbonate lenses 8 +() 085-0 Fax +() 085-0077 www.venturelightingeurope.com E-mail: sales@venturelighting.co.uk

Features: Clear tubular lamps with UV Shield for Horizontal operation in open luminaires. Open Rated Reactor Control Gear 00 HIPT 00W/H75/UVS/T5/PS/K 007 9000 5000 000 - -5 68 Clear HOR±75 A 50 HIPT 50W/H75/UVS/T5/PS/K 008 000 0000 000 - -5 68 Clear HOR±75 B Open Rated Open Rated Horizontal Tubular Lamps Applications: For use in Low Bay luminaires for warehouses, retail sheds, showrooms and other commercial and industrial applications. White-lux are direct replacements for HPS lamps. Mercury Control Gear 50 HIPT 50W/H75/UVS/T5/PS/K 005 000 000 000 - -5 68 Clear HOR±75 A 00 HIPT 00W/H75/UVS/T5/PS/K 006 8000 0000 000 - -5 68 Clear HOR±75 B Open Rated White-Lux Tubular HPS Control Gear Watts Description No. Lumens Hours * (K) (Min) (Min) RA Finish Pos. Fig. Qty 50 HIPT 50W/H75/LU/UVS/T5/K 009 0000 000 000 - -5 68 Clear HOR±75 A 00 HIPT 00W/H75/LU/UVS/T5/K 0050 6000 0000 000 - -5 68 Clear HOR±75 B Some lamp descriptions include the digit International Ra/CCT Code Lamps Uni-Form Pulse Start/White-Lux A T5 Dia. = 5mm MOL = mm LCL = mm B T5 Dia. = 5mm MOL = 85mm LCL = 6mm 9 +() 085-0 Fax +() 085-0077 www.venturelightingeurope.com E-mail: sales@venturelighting.co.uk

White-Lux Lamps White-Lux Plus White-Lux Plus metal halide lamps in 50,70, 00, 50, 50, 00, 600 and 000 wattages offer increased lumen efficiency over existing White-Lux metal halide lamps. These lamps can be used to convert the harsh yellow light of sodium lamps in existing installations to clean white metal halide light. Enclosed Rated Features: High lumen efficiency Long lamp life Enclosed and open fixture designs Uni-Form formed body arc tube for faster starting UV Shield option available (UVS) HPS Control Gear 50 HIE 50W/U/LU/K 67 00V 0000V 000 - - 68 Clear U A 70 HIE 70W/U/LU/K 77 5600V 5000V 000 - - 68 Clear U A 70 HIE 70W/C/U/LU/K 67 500V 5000V 700 - - 70 Coated U A 70 HIE 70W/U/LU/K 660 5600V 5000V 00 - - 68 Clear U A 70 HIE 70W/C/U/LU/K 9670 500V 5000V 00 - - 70 Coated U A 00 HIE 00W/U/LU/K 500 9000V 5000V 000 - - 68 Clear U A 00 HIE 00W/C/U/LU/K 90 8500V 5000V 700 - - 70 Coated U A 00 HIE 00W/U/LU/K 7957 9000V 5000V 00 - - 68 Clear U A 00 HIE 00W/C/U/LU/K 557 8500V 5000V 00 - - 70 Coated U A 50 HIE 50W/U/LU/K 05 000V 5000V 000 - - 68 Clear U A 50 HIE 50W/C/U/LU/K 056 00V 5000V 700 - - 70 Coated U A 50 HIE 50W/C/U/LU/K 69876 00V 5000V 00 - - 70 Coated U A Open Rated HPS Control Gear 70 HIPE 70W/C/U/LU/UVS/K 590 5000V 5000V 00 - - 70 Coated U B 70 HIPE 70W/C/V/LU/UVS/7K 869 5000V 5000V 700 - - 70 Coated V±5 B 70 HIPE 70W/U/LU/UVS/K 000 500V 5000V 000 - - 68 Clear U B 70 HIPE 70W/C/U/LU/UVS/K 000 5000V 5000V 700 - - 70 Coated U B 00 HIPE 00W/U/LU/UVS/K 859 8500V 5000V 00 - -5 68 Clear U B 00 HIPE 00W/C/U/LU/UVS/K 65850 800V 5000V 00 - -5 70 Coated U B 00 HIPE 00W/C/V/LU/UVS/7K 968 800V 5000V 700 - -5 70 Coated V±5 B 00 HIPE 00W/U/LU/UVS/K 000 8500V 5000V 000 - -5 68 Clear U B 00 HIPE 00W/C/U/LU/UVS/K 0005 800V 5000V 700 - -5 70 Coated U B 00 HIPE 00W/U/LU/E90/UVS/K 0050 8500V 5000V 000 - -5 68 Clear U C 50 HIPE 50W/U/LU/UVS/K 8 00V 5000V 00 - -5 68 Clear U B 50 HIPE 50W/C/U/LU/UVS/K 8 600V 5000V 00 - -5 70 Coated U B 50 HIPE 50W/C/V/LU/UVS/7K 700 600V 5000V 700 - -5 70 Coated V±5 B 50 HIPE 50W/U/LU/E90/UVS/K 005 00V 5000V 000 - -5 68 Clear U C 50 HIPE 50W/C/U/LU/E90/UVS/K 008 600V 5000V 700 - -5 70 Coated U C 50 HIPE 50W/U/LU/UVS/K 0006 00V 5000V 000 - -5 68 Clear U B 50 HIPE 50W/C/U/LU/UVS/K 0007 600V 5000V 700 - -5 70 Coated U B Conversion Kit (Lamp and Ignitor) They also provide the added benefit of a formed body arc tube for faster starting. White-Lux Plus metal halide lamps operate on standard HPS ballasts and ignitors. HPS Control Gear 70 HIPE 70W/U/LU/UVS/K 00 500V 5000V 000 - - 68 Clear U D 70 HIPE 70W/C/U/LU/UVS/K 00 5000V 5000V 700 - - 70 Coated U D Some lamp descriptions include the digit International Ra/CCT Code A B C D E 0 E5 Dia. = 5mm MOL = mm LCL = 89mm Base = E7 EX5 Dia. = 5mm MOL = mm LCL = 89mm Base = E7 E90 Dia. = 90mm MOL = 5mm LCL = mm KIT Dia. = 5mm MOL = mm LCL = 89mm Base = E7 E90 Dia. = 90mm MOL = 5mm LCL = mm +() 085-0 Fax +() 085-0077 www.venturelightingeurope.com E-mail: sales@venturelighting.co.uk

Applications: Floodlighting Factories Car Parks Enclosed Rated White-Lux Plus HPS Control Gear 50 HIE 50W/V/LU/K 668 000 0000 000 - -5 68 Clear V±5 E 50 HIE 50W/C/V/LU/K 5666 000 0000 700 - -5 70 Coated V±5 E 50 HIE 50W/C/H75/LU/K 6 0000 0000 700 - -6 70 Coated HOR±75 E 00 HIE 00W/V/LU/K 60 000 0000 000 - -6 68 Clear V±5 F 6 00 HIE 00W/C/V/LU/K 5695 000 0000 700 - -6 70 Coated V±5 F 6 00 HIE 00W/C/H75/LU/K 680 8000 0000 700-5-8 70 Coated HOR±75 F 6 000 HIE 000W/V/LU/BT0/K 005 90000 8000 000-0-5 68 Clear V±5 P 6 Open Rated HPS Control Gear 50 HIPE 50W/HBU/LU/UVS/K 006 000V 0000V 000 - -6 68 Clear V±5 C 50 HIPE 50W/C/HBU/LU/UVS/K 0076 0000V 0000V 700 - -6 70 Coated V±5 C 50 HIPE 50W/C/H75/LU/UVS/K 986 0000 0000 700 - -6 70 Coated HOR±75 C 00 HIPE 00W/V/LU/UVS/K 0077 000 0000 000-5-8 68 Clear V±5 G 6 00 HIPE 00W/C/V/LU/UVS/K 00 0000 0000 700-5-8 70 Coated V±5 G 6 00 HIPE 00W/C/H75/LU/UVS/K 05 8000 0000 700-5-8 70 Clear HOR±75 G 6 Open Rated (High Output) Retail warehouses Security lighting Showrooms/Warehouses For Tubular Open Rated Lamps See Page HPS Control Gear 00 HIPE 00W/V/LU/UVS/HO/K 598 7000 0000 000-5-8 68 Clear V±5 G 6 00 HIPE 00W/C/V/LU/UVS/HO/K 067 5000 0000 700-5-8 70 Coated V±5 G 6 Enclosed Rated White-Lux Tubular HPS Control Gear 70 HIT 70W/U/LU/K 7 500V 5000V 000 - - 68 Clear U H 00 HIT 00W/U/LU/T8/K 7678 9000V 5000V 000 - - 68 Clear U H 00 HIT 00W/U/LU/T6/K 8768 9000V 5000V 000 - - 68 Clear U I 50 HIT 50W/U/LU/T8/K 67 000V 5000V 000 - - 68 Clear U H 50 HIT 50W/U/LU/T6/K 7 000V 5000V 000 - - 68 Clear U I 50 HIT 50W/U/LU/K 8768 9000V 0000V 000-5 5-0 68 Clear U J 50 HIT 50W/U/LU/5K 0855 6800V 0000V 500-5 5-0 75 Clear U J 50 HIT 50W/H75/LU/K 7965 0000 5000 000-5 5-0 68 Clear HOR±75 N 00 HIT 00W/U/LU/K 9878 6000V 0000V 000-5 5-0 68 Clear U K 00 HIT 00W/U/LU/5K 0 000V 0000V 500-5 5-0 75 Clear U K 00 HIT 00W/H75/LU/K 898 0000 5000 000-5 5-0 68 Clear HOR±75 O 600 HIT 600W/U/LU/K 56 55000V 000V 000-5 5-0 68 Clear BU±90 L 6 000 HIT 000W/U/LU/K 865 90000V 8000V 000-5 0-5 68 Clear U M 6 000 HIT 000W/U/LU/5K 0008 80000V 8000V 5000-5 0-5 68 Clear U M 6 Lamps White-Lux Some lamp descriptions include the digit International Ra/CCT Code F G H I J E0 Dia. = 0mm MOL = 96mm LCL = 8mm E0 Dia. = 0mm MOL = 96mm LCL = 8mm T8 Dia. = 8mm MOL = 56mm LCL = 0mm Base = E7 T8 T6 Dia. = 6mm MOL = mm LCL = mm T6 Dia. = 6mm MOL = 5mm LCL = 6mm K T6 Dia. = 6mm MOL = 85mm LCL = 75mm L T76 Dia. = 76mm MOL = 8mm LCL = 75mm M T76 Dia. = 76mm MOL = 0mm LCL = 0mm N T8 T6 Dia. = 6mm MOL = 5mm LCL = 6mm O T8 T6 Dia. = 6mm MOL = 85mm LCL = 75mm P BT0 Dia. = 0mm MOL = 96mm LCL = 8mm +() 085-0 Fax +() 085-0077 www.venturelightingeurope.com E-mail: sales@venturelighting.co.uk

Lamps Energy Saving Lamps - With Achievable Savings of Almost 50% There is now a rapidly growing demand for ever more energy efficient lighting systems to help the environment. Venture Lighting is leading the way worldwide in developing innovative new energy efficient lighting products to help reduce overall energy usage costs but without compromising on lighting quality. Now, Venture s pulse start metal halide lighting systems are widely regarded as the most advanced available. They offer more light than conventional systems, excellent colour uniformity, longer life and most important of all significant energy savings +() 085-0 Fax +() 085-0077 www.venturelightingeurope.com E-mail: sales@venturelighting.co.uk

Enclosed Rated Reactor Control Gear 00 HIE 00W/U/PS/70 887 000V 5000V 000 - - 68 Clear U A 00 HIE 00W/C/U/PS/77 0058 0000V 5000V 700 - - 70 Coated U A 50 HIE 50W/V/PS/70 08 7000 0000+ 000 - -6 68 Clear V±5 C 6 50 HIE 50W/C/V/PS/77 0056 5000 0000+ 700 - -6 70 Coated V±5 C 6 50 HIE 50W/H75/PS/70 9607 000 5000 000 - -6 68 Clear HOR±75 C 6 Open Rated Reactor Control Gear 00 HIPE 00W/V/UVS/PS/70 0067 0000 5000 000 - -5 68 Clear V±5 B 50 HIPE 50W/V/UVS/PS/70 0068 5000 0000+ 000-5-8 68 Clear V±5 D 6 Open Rated Energy Saving Uni-Form Pulse Start The 00 and 50 watt Uni-Form Energy Saving lamps are designed to replace standard 50 and 00 watt metal halide lamps. These lamps operate on reactor/ignitor ballast systems specifically designed to realise the best performance from these light sources, including longer life and better lumen maintenance. Features: Higher lumens vs. standard designs System savings, up to 50 watts Longer life (up to 0,000 hours) Faster warm-up and hot restrike Improved lumen maintenance Reduced colour shift Better cold temperature starting (-0 C) UV Shield option available (UVS) Applications: Petrol station canopies Industrial high bay and low bay fittings Larger retail areas Reactor Control Gear 00 HIPE 00W/C/V/UVS/PS/77 0059 9000 5000 700 - -5 70 Coated V±5 B 50 HIPE 50W/C/V/UVS/PS/77 0057 000 0000+ 700-5-8 70 Coated V±5 D 6 NOTE: A life rating of 0,000+ hours means that 70% of the lamps initially installed will still be operating after 0,000 hours. Lamps Uni-Form Pulse Start Enclosed Rated Pulse Start Tubular Reactor Control Gear 00 HIT 00W/H75/PS/K 0085 0000 5000 000-5-8 68 Clear HOR±75 H 50 HIT 50W/H75/PS/K 008 000 0000 000-5-8 68 Clear HOR±75 I Open Rated 0 HIPE 0W/C/V/UVS/EL/PS/77 090 0000 0000+ 700-5-8 70 Coated V±5 D 6 0 HIPE 0W/V/UVS/EL/PS/70 9786 000 0000+ 000-5-8 70 Clear V±5 D 6 Some lamp descriptions include the digit International Ra/CCT Code A B C D H I E90 Dia. = 90mm MOL = 5mm LCL = mm E90 Dia. = 90mm MOL = 5mm LCL = mm E0 Dia. = 0mm MOL = 965mm LCL = 8mm E0 Dia. = 0mm MOL = 96mm LCL = 8mm T8 T6 Dia. = 6mm MOL = 5mm LCL = 6mm T6 Dia. = 6mm MOL = 85mm LCL = 75mm +() 085-0 Fax +() 085-0077 www.venturelightingeurope.com E-mail: sales@venturelighting.co.uk

Uni-Form Pulse Start Lamps Uni-Form Pulse Start Enclosed Rated Mercury Control Gear 50 HIE 50W/V/PS/70 8980 5000 5000 000 - -5 68 Clear V±5 A 50 HIE 50W/C/V/PS/77 65 800 5000 700 - -5 70 Coated V±5 A 50 HIE 50W/C/H75/PS/77 997 0000 5000 700 - -5 70 Coated HOR±75 A 00 HIE 00W/V/PS/70 9008 000 0000+ 000 - -6 68 Clear V±5 C 6 00 HIE 00W/C/V/PS/77 60 000 0000+ 700 - -6 70 Coated V±5 C 6 00 HIE 00W/C/H75/PS/77 6859 0000 0000 700 - -6 70 Coated HOR±75 C 6 Open Rated Mercury Control Gear 50 HIPE 50W/V/UVS/PS/70 0008 800 5000 000 - -6 68 Clear V±5 B 00 HIPE 00W/V/UVS/PS/70 005 000 0000+ 000-5-8 68 Clear V±5 D 6 Open Rated HPS Control Gear 50 HIPE 50W/V/UVS/PS/70 7 7000 0000+ 000-5-8 68 Clear V±5 D 6 Open Rated Mercury Control Gear 50 HIPE 50W/C/V/UVS/PS/77 00 000 5000 700 - -6 70 Coated V±5 B 00 HIPE 00W/C/V/UVS/PS/77 00 0000 0000+ 700-5-8 70 Coated V±5 D 6 Open Rated HPS Control Gear 50 HIPE 50W/C/V/UVS/PS/77 757 5000 0000+ 700-5-8 70 Coated V±5 D 6 Enclosed Rated Uni-Form 50, 00 and 50 Watt High Performance lamps are designed to out perform standard pinch body 50W and 00W metal halide lamps. These lamps operate on reactor/ignitor ballast systems specifically designed to realise the best performance from these light sources, including longer life and better lumen maintenance. 50W lamps operate on HPS Control Gear High Performance Features: Higher lumens vs. standard designs System savings, up to 50 watts Longer life ( 0,000+hours) Faster warm-up and hot restrike Improved lumen maintenance Reduced colour shift Better cold temperature starting (-0 C) UV Shield option available (UVS) Impact GuardTM coating available for base-up application- call for details Mercury Control Gear 50 HIT 50W/H75/PS/70 60 000 5000 000-5-8 68 Clear HOR±75 E 00 HIT 00W/H75/PS/70 568 000 0000 000-5-8 68 Clear HOR±75 F Some lamp descriptions include the digit International Ra/CCT Code A B C D E F E90 Dia. = 90mm MOL = 5mm LCL = mm E90 Dia. = 90mm MOL = 5mm LCL = mm E0 Dia. = 0mm MOL = 96mm LCL = 8mm E0 Dia. = 0mm MOL = 96mm LCL = 8mm T8 T6 Dia. = 6mm MOL = 5mm LCL = 6mm T8 T6 Dia. = 6mm MOL = 85mm LCL = 75mm +() 085-0 Fax +() 085-0077 www.venturelightingeurope.com E-mail: sales@venturelighting.co.uk

Tubular Metal Halide Features: Full range of wattages Unique tubular lamps Compact light source Choice of colour temperatures Applications: Floodlighting Sports lighting General lighting Street lighting For Tubular Open Rated Lamps See Page Enclosed Rated Pulse Start Tubular Reactor Control Gear 00 HIT 00W/H75/PS/K 0085 0000 5000 000-5-8 68 Clear HOR±75 H 50 HIT 50W/H75/PS/70 60 000 5000 000-5-8 68 Clear HOR±75 H 50 HIT 50W/H75/PS/K 008 000 0000 000-5-8 68 Clear HOR±75 I 00 HIT 00W/H75/PS/70 568 0000 0000 000-5-8 68 Clear HOR±75 I Enclosed Rated White-Lux Plus Tubular HPS Control Gear 70 HIT 70W/U/LU/K 7 500V 5000V 000 - - 68 Clear U A 00 HIT 00W/U/LU/T8/K 7678 9000V 5000V 000 - - 68 Clear U A 00 HIT 00W/U/LU/T6/K 8768 9000V 5000V 000 - - 68 Clear U B 50 HIT 50W/U/LU/T8/K 67 000V 5000V 000 - - 68 Clear U A 50 HIT 50W/U/LU/T6/K 7 000V 5000V 000 - - 68 Clear U B Enclosed Rated White-Lux Tubular HPS Control Gear 50 HIT 50W/U/LU/K 8768 9000V 0000V 000-5 5-0 68 Clear U C 50 HIT 50W/U/LU/5K 0855 6800V 0000V 500-5 5-0 75 Clear U C 50 HIT 50W/H75/LU/K 7965 9000 5000 000-5 5-0 68 Clear HOR±75 H 00 HIT 00W/U/LU/K 9878 6000V 5000V 000-5 5-0 68 Clear U D 00 HIT 00W/U/LU/5K 0 000V 5000V 500-5 5-0 75 Clear U D 00 HIT 00W/H75/LU/K 898 0000 5000 000-5 5-0 68 Clear HOR±75 I 600 HIT 600W/U/LU/K 56 55000V 000V 000-5 5-0 68 Clear U E 6 000 HIT 000W/U/LU/K 865 90000V 8000V 000-5 0-5 68 Clear U F 6 000 HIT 000W/U/LU/5K 0008 80000V 8000V 5000-5 0-5 68 Clear U F 6 Lamps Tubular Metal Halide Enclosed Rated Euro Tubular Mercury Control Gear 50 HIT 50W/U/EURO/K 950 000V 0000V 000-5 5-0 68 Clear U C 50 HIT 50W/HOR/EURO/K 577 000 0000 000-5 5-0 68 Clear HOR±5 C 50 HIT 50W/U/EURO/5K 000 9000V 7500V 5000-5 5-0 68 Clear U C 00 HIT 00W/U/EURO/5K 000 000V 5000V 5000-5 5-0 68 Clear U D 00 HIT 00W/U/EURO/K 580 6000V 5000V 000-5 0-5 68 Clear U D 00 HIT 00W/HOR/EURO/K 880 0000 5000 000-5 0-5 68 Clear HOR±5 D Enclosed Rated Tubular Reactor Control Gear Lamp Watts Description Current No. Lumens Hours (K) (Min) (Min) RA Finish Pos. Fig. Qty 000 HIT 000W/U/EURO/K Note ➀ 8. 00008 90000V 8000V 000-5 0-5 68 Clear U F 6 000 HIT 000W/U/EURO/5K Note ➀ 8. 008 80000V 8000V 5000-5 0-5 68 Clear U F 6 000 HIT 000W/U/K Note ➀ 8.8 00066 0000V 5000V 000-5 0-5 68 Clear U G 6 000 HIT 000W/U/0V/5K Note ➀ 6.5 00067 85000V 5000V 500-5 0-5 68 Clear U G 6 Some lamp descriptions include the digit International Ra/CCT Code A T8 Dia. = 8mm MOL = 56mm LCL = 0mm Base = E7 B T6 Dia. = 6mm MOL = mm LCL = mm C T6 Dia. = 6mm MOL = 5mm LCL = 6mm C T6 Dia. = 6mm MOL = 5mm LCL = 6mm PO D T6 Dia. = 6mm MOL = 85mm LCL = 75mm Notes Note ➀ Ignitor can be supplied with lamp D T6 Dia. = 6mm MOL = 85mm LCL = 75mm PO E F G H I T76 Dia. = 76mm MOL = 8mm LCL = 75mm T76 Dia. = 76mm MOL = 0mm LCL = 0mm T00 Dia. = 00mm MOL = 0mm LCL = 0mm T8 T6 Dia. = 6mm MOL = 5mm LCL = 6mm T8 T6 Dia. = 6mm MOL = 85mm LCL = 75mm 5 +() 085-0 Fax +() 085-0077 www.venturelightingeurope.com E-mail: sales@venturelighting.co.uk

Euro Metal Halide Lamps Euro Metal Halide Euro Lamps make up a range of metal halide lamps suitable for mercury ballasts with either 600-900 volt -wire parallel ignitors, or 000-500 volt ignitors. The 5W Mercury Retrofit lamp operates on a mercury ballast with an 800-500 volt ignitor. Enclosed Rated 5W Mercury Retrofit Mercury Control Gear 5 HIE 5W/C/HBU/K 97765 000V 000V 700 - - 70 Coated BU±90 A 5 HIE 5W/C/HBD/K 597 000V 000V 700 - - 70 Coated BD±90 A Enclosed Rated Features: Operates on mercury ballast with standard metal halide ignitor Vertical and horizontal lamps provide high performance and long life Tubular and elliptical design Clear and coated bulb finishes Mercury Control Gear 75 HIE 75W/U/E5/EURO/K 897 000V 0000V 000-5 5-0 68 Clear U B 75 HIE 75W/C/U/E5/EURO/K 79 00V 0000V 700-5 5-0 70 Coated U B 75 HIE 75W/U/EURO/K 679 000V 0000V 000-5 5-0 68 Clear U C 75 HIE 75W/C/U/EURO/K 0698 00V 0000V 700-5 5-0 70 Coated U C 50 HIE 50W/BU/EURO/K 80 000V 0000V 000-5-0 68 Clear BU±5 C 50 HIE 50W/C/BU/EURO/K 80 000V 0000V 700-5-0 70 Coated BU±5 C 50 HIE 50W/U/EURO/K 886 000V 0000V 000-5 5-0 68 Clear U C 50 HIE 50W/C/U/EURO/K 0 0000V 0000V 700-5 5-0 70 Coated U C Enclosed Rated Tubular Mercury Control Gear 50 HIT 50W/U/EURO/K 950 000V 0000V 000-5 5-0 68 Clear U D 50 HIT 50W/U/EURO/5K 000 9000V 7500V 5000-5 5-0 75 Clear U D 50 HIT 50W/HOR/EURO/K 577 000 0000H 000H -5 5-0 68 Clear HOR±5 D Some lamp descriptions include the digit International Ra/CCT Code Applications: Petrol station canopies Industrial high bay and low bay fittings Larger retail areas A B C D D 6 E5 Dia. = 5mm MOL = mm LCL = 89mm Base = E7 E5 Dia. = 5mm MOL = mm LCL = 89mm Base = E7 E90 Dia. = 90mm MOL = 5mm LCL = mm T6 Dia. = 6mm MOL = 5mm LCL = 6mm T6 Dia. = 6mm MOL = 5mm LCL = 6mm PO +() 085-0 Fax +() 085-0077 www.venturelightingeurope.com E-mail: sales@venturelighting.co.uk

Euro Metal Halide Enclosed Rated Mercury Control Gear 00 HIE 00W/BU/EURO/K 5 0000 5000 000-5 0-5 68 Clear BU±5 B 6 00 HIE 00W/C/BU/EURO/K 55 8000 5000 700-5 0-5 70 Coated BU±5 B 6 00 HIE 00W/C/HOR/EURO/K 6958 8000 5000 700-5 0-5 70 Coated HOR±5 B 6 00 HIE 00W/U/EURO/K 07 6000V 5000V 000-5 8-68 Clear U B 6 00 HIE 00W/C/U/E90/EURO/K* 58 000V 5000V 700-5 8-70 Coated U A 00 HIE 00W/C/U/EURO/K 88787 000V 5000V 700-5 8-70 Coated U B 6 * Reduced jacket Open Rated Mercury Control Gear 00 HIPE 00W/BU/EURO/K 99 8000 5000 000-5 0-5 68 Clear BU±5 D 6 00 HIPE 00W/C/BU/EURO/K 90 6000 5000 700-5 0-5 70 Coated BU±5 D 6 Enclosed Rated Tubular Mercury Control Gear 00 HIT 00W/U/EURO/K 580 6000V 5000V 000-5 0-5 68 Clear U C 00 HIT 00W/U/EURO/5K 000 000V 5000V 5000-5 0-5 75 Clear U C 00 HIT 00W/HOR/EURO/K 880 0000 5000 000-5 0-5 68 Clear HOR±5 C Lamps Euro Metal Halide Enclosed Rated Tubular Reactor Control Gear Lamp Watts Description Current No. Lumens Hours (K) (Min) (Min) RA Finish Pos. Fig. Qty 000 HIT000W/U/EURO/K Note ➀ 8. 00008 90000V 8000V 000-5 0-5 68 Clear U E 6 000 HIT000W/U/EURO/5K Note ➀ 8. 008 80000V 8000V 5000-5 0-5 68 Clear U E 6 000 HIT 000W/U/K Note ➀ 8.8 00066 0000V 5000V 000-5 0-5 68 Clear U F 6 000 HIT 000W/U/0V/5K Note ➀ 6.5 00067 85000V 5000V 500-5 0-5 68 Clear U F 6 Some lamp descriptions include the digit International Ra/CCT Code Notes Note ➀ Ignitor can be supplied with lamp A B B C C E90 Dia. = 90mm MOL = 5mm LCL = mm E0 Dia. = 0mm MOL =96mm LCL = 8mm E0 Dia. = 0mm MOL = 96mm LCL = 8mm PO T6 Dia. = 6mm MOL = 85mm LCL = 75mm T6 Dia. = 6mm MOL = 85mm LCL = 75mm PO D E F BT0 Dia. =0mm MOL = 96mm LCL = 8mm T76 Dia. = 76mm MOL = 0mm LCL = 0mm T00 Dia. = 00mm MOL = 0mm LCL = 0mm 7 +() 085-0 Fax +() 085-0077 www.venturelightingeurope.com E-mail: sales@venturelighting.co.uk

Natural White Full Spectrum Natural White Lamps New Natural White lamps offer light output in all parts of the visual spectrum to provide better colour than ceramic metal halide lamps. With Natural White lamps blues are true blue and reds are more vibrant; whites are whiter and skin tones look like they're under sunlight. More consistent lamp to lamp colour Light output in all parts of the visual spectrum Excellent colour uniformity and stability for the life of the lamp Provides better colour than ceramic metal halide Ideal for daylight harvesting applications Lamps feature superior Uni-Form pulse start technology Ceramic Metal Halide 000K - 90 CRI Uni-Form Natural White 5000K - 90+ CRI Compact Fluorescent 500K - 80 CRI 8 +() 085-0 Fax +() 085-0077 www.venturelightingeurope.com E-mail: sales@venturelighting.co.uk

Natural White Features: Lamps with improved Colour Rendering Index (Ra) for high bay luminaires without protective cover glasses. Open Rated Natural White Applications: Retail stores or commercial and industrial applications requiring excellent colour rendering and colour matching. Museums, Art Galleries. Lamp Product Intitial Avg. Life CCT Warm-Up Restrike Oper. Case Note ➀ 5 HIT 5W/G/UVS/950 6750 00 0000V 5000 - - 90+ Clear U C 5 50 HIT 50w/G/UVS/950 5897 000 0000V 5000 - - 90+ Clear U B 5 50 HIPE 50w/C/U/950 95 000 5000V 5000 - - 90+ Coated U D 5 HIPE 5W/BU/UVS/PS/950 Note ➂ 99 000 0000+ 5000 - -6 90+ Clear BU±5 E 0 HIPE 0W/BU/UVS/PS/950 Note ➃ 586 8500 0000+ 5000-5-8 90+ Clear BU±5 A 6 65 HIPE 65W/C/V/UVS/PS/950 Note ➁ 56 00 0000+ 5000-5-8 90+ Coated V±5 A 6 Some lamp descriptions include the digit International Ra/CCT Code Notes Note ➀ Scotopically Enhanced Task Lumens (S/P) 0.78 Note ➁ Lamp operates at 65W on 00W Mercury ballast Note ➂ Lamp operates on 50W Mercury ballast Note ➃ Lamp operates on 50W ballast Lamps Natural White A E0 Dia. = 0mm MOL = 96mm LCL = 8mm B G Dia. = mm MOL = 0mm LCL = 56mm Base = G C G Dia. =9mm MOL = 90mm LCL =56mm Base = G D E5 Dia. = 5mm MOL = mm LCL = 89mm Base = E7 E E90 Dia. = 90mm MOL = 5mm LCL = mm 9 +() 085-0 Fax +() 085-0077 www.venturelightingeurope.com E-mail: sales@venturelighting.co.uk

Ceramic Metal Halide Lamps Ceramic Master-PLUS Metal Halide Ceramic Master-PLUS Metal Halide lamps from Venture offer an unbeatable combination of performance and reliability, as you'd expect from the world's leading name in Metal Halide technology. Features: Excellent light quality Exceptional colour rendering and consistency Increased lamp life Lower maintenance requirements Reduced heat output Significantly less power consumption than halogen equivalents Ideal for use with quality interior décors Ceramic Master-PLUS Conventional Arc Tube Venture Ceramic Master-PLUS lamps use the latest in ceramic arc tube design. Our slip cast arc tube provides excellent reliability due to its factory formed construction. The single piece arc tube with contours similar to Venture lamps offers better colour control, higher Lumens and longer life Energy Efficient Venture Ceramic lamps are highly energy efficient and offer truly exceptional performance, delivering up to 00 lumens per watt. They therefore consume considerably less energy and generate less heat than a halogen equivalent. Maintenance requirements are reduced too, as the lamps are both robust and reliable and offer a life expectancy of up to 8,000 hours. Excellent Light & Colour The quality and consistency of light generated by Venture Metal Halide lamps has always been at the forefront of our design technology. The Venture Ceramic Master-PLUS range offers a clean white light and excellent colour rendering, making it ideal for display use and for accentuating quality interiors and decors. Colours, features and textures really stand out. Lamp-to-lamp colour uniformity is comparable to Venture lamps, so the effect you want is never lost. 0 +() 085-0 Fax +() 085-0077 www.venturelightingeurope.com E-mail: sales@venturelighting.co.uk

Ceramic Master-PLUS Metal Halide Ceramic Lamp G8.5 Lamp Product Initial Avg. Life CCT Burn Ctn. Watts Description No. Lumens Hours (K) RA Pos. Fig Qty 0W CM-PLUS TC 0W/U/UVS/G8.5/80 005 800 9000 000 80+ U A 0W CM-PLUS TC 0W/U/UVS/G8.5/9 0055 800 9000 00 90+ U A 5W CM-PLUS TC 5W/U/UVS/G8.5/80 0056 00 000 000 80+ U A 5W CM-PLUS TC 5W/U/UVS/G8.5/9 0057 00 000 00 90+ U A 70W CM-PLUS TC 70W/U/UVS/G8.5/80 0058 7000 000 000 80+ U A 70W CM-PLUS TC 70W/U/UVS/G8.5/9 0059 6600 000 00 90+ U A Ceramic Lamp G Lamp Product Initial Avg. Life CCT Burn Ctn. Watts Description No. Lumens Hours (K) RA Pos. Fig Qty 0W CM-PLUS T 0W/U/UVS/G/80 0060 800 0000 000 80+ U B 0W CM-PLUS T 0W/U/UVS/G/9 006 650 0000 00 90+ U B 5W CM-PLUS T 5W/U/UVS/G/80 006 00 000 000 80+ U B 5W CM-PLUS T 5W/U/UVS/G/9 006 00 000 00 90+ U B 70W CM-PLUS T 70W/U/UVS/G/80 006 7000 000 000 80+ U C 70W CM-PLUS T 70W/U/UVS/G/9 0065 6600 000 00 90+ U C 00W CM-PLUS T 00W/U/UVS/G/80 0066 9500 000 000 80+ U D 00W CM-PLUS T 00W/U/UVS/G/9 0067 9000 000 00 90+ U D 50W CM-PLUS T 50W/U/UVS/G/80 0068 5000 000 000 80+ U D 50W CM-PLUS T 50W/U/UVS/G/9 0069 500 000 00 90+ U D Ceramic Lamp MH-DE Lamp Product Initial Avg. Life CCT Burn Ctn. Watts Description No. Lumens Hours (K) RA Pos. Fig Qty 70W CM-PLUS TD 70W/U/UVS/RX7s/80 0070 7000 5000 000 80+ U E 70W CM-PLUS TD 70W/U/UVS/RX7s/9 007 6600 5000 00 90+ U E 50W CM-PLUS TD 50W/U/UVS/RX7s/80 007 000 5000 000 80+ U F 50W CM-PLUS TD 50W/U/UVS/RX7s/9 007 500 5000 00 90+ U F Ceramic Lamp Tubular Lamp Product Initial Avg. Life CCT Burn Ctn. Watts Description No. Lumens Hours (K) RA Pos. Fig Qty 70W CM-PLUS TT 70W/U/UVS/80 007 7000 8000 000 80+ U H 70W CM-PLUS TT 70W/U/UVS/9 0075 6600 8000 00 90+ U H 00W CM-PLUS TT 00W/U/UVS/80 0076 9500 8000 000 80+ U G 00W CM-PLUS TT 00W/U/UVS/9 0077 9000 8000 00 90+ U G 50W CM-PLUS TT 50W/U/UVS/80 0078 000 8000 000 80+ U G 50W CM-PLUS TT 50W/U/UVS/9 0079 500 8000 00 90+ U G Ceramic Lamp Elliptical Lamp Product Initial Avg. Life CCT Burn Ctn. Watts Description No. Lumens Hours (K) RA Pos. Fig Qty 70W CM-PLUS ED 70W/U/UVS/80 0080 7000 8000 000 80+ U I 70W CM-PLUS ED 70W/U/UVS/9 008 6600 8000 00 90+ U I 00W CM-PLUS ED 00W/U/UVS/80 008 9500 8000 000 80+ U I 00W CM-PLUS ED 00W/U/UVS/9 008 9000 8000 00 90+ U I 50W CM-PLUS ED 50W/U/UVS/80 008 000 8000 000 80+ U I 50W CM-PLUS ED 50W/U/UVS/9 0085 500 8000 00 90+ U I All performance data is based on operation on Ventronic electronic ballasts Some lamp descriptions include the digit International Ra/CCT Code Lamps Cermic Metal Halide A B C D E F G8.5 Dia. =.5mm MOL = 85mm LCL =5mm G Dia. =.5mm MOL = 90mm LCL = 56mm Base = G G Dia. = 9mm MOL = 90mm LCL = 56mm Base = G G Dia. = 9mm MOL = 00mm LCL = 56mm Base = G CMP70 Dia. = mm MOL = 0mm LCL = 57mm Base = RX7S CMP50 Dia. = mm MOL = 5mm LCL = 66mm Base = RX7S G T6 Dia. = 6mm MOL = mm LCL = mm H T8 Dia. = 8mm MOL = 56mm LCL = 0mm Base = E7 I E5 Dia. = 5mm MOL = mm LCL = 89mm Base = E7 +() 085-0 Fax +() 085-0077 www.venturelightingeurope.com E-mail: sales@venturelighting.co.uk

CWA Metal Halide Lamps CWA Metal Halide Direct replacement for Multi-vapor and Super Metal Arc lamps. Operate on CWA control gear. Enclosed Rated Features: Full range of wattages Clear and coated bulb finishes Reduced jacket options Choice of colour temperatures 00 watt lamps are open rated when operated base up ±5 Asymmetric arc tube design allows horizontal ±5 operation Applications: Universal Floodlighting Sports lighting General lighting Vertical Architectural area lighting Commercial downlighting Industrial highbay Horizontal Advertising hoardings Petrol station canopies Indoor sports CWA Control Gear Watts Lamp Description Product No. Initial Lumens Avg. Life Hours CCT (K) Warm-Up (Min) Restrike (Min) RA Finish Oper. Pos. Fig. Case Qty 75 HIE 75W/U/E5/EURO/K 897 000V 0000V 000-5 5-0 68 Clear U H 75 HIE 75W/C/U/E5/EURO/K 79 00V 0000V 700-5 5-0 70 Coated U H 75 HIE 75W/U/EURO/K 679 000V 0000V 000-5 5-0 68 Clear U A 75 HIE 75W/C/U/EURO/K 0698 00V 0000V 700-5 5-0 70 Coated U A 50 HIE 50W/BU/EURO/K 80 000 0000 000-5-0 68 Clear BU±5 A 50 HIE 50W/C/BU/EURO/K 80 000 0000 700-5-0 70 Coated BU±5 A 50 HIE 50W/U/EURO/K 886 000V 0000V 000-5 5-0 68 Clear U A 50 HIE 50W/C/U/EURO/K 0 0000V 0000V 700-5 5-0 70 Coated U A Enclosed Rated CWA Control Gear Watts Lamp Description Product No. Initial Lumens Avg. Life Hours CCT (K) Warm-Up (Min) Restrike (Min) RA Finish Oper. Pos. Fig. Case Qty 00 HIE 00W/BU/EURO/K 5 0000 5000 000-5 0-5 68 Clear BU±5 B 6 00 HIE 00W/C/BU/EURO/K 55 8000 5000 700-5 0-5 70 Coated BU±5 B 6 00 HIE 00W/C/HOR/EURO/K 6958 8000 5000 700-5 0-5 70 Coated HOR±5 C 6 00 HIE 00W/U/EURO/K 07 6000V 5000V 000-5 8-68 Clear U B 6 00 HIE 00W/C/U/E90/EURO/K* 58 000V 5000V 700-5 8-70 Coated U A 00 HIE 00W/C/U/EURO/K 88787 000V 5000V 700-5 8-70 Coated U B 6 * Reduced jacket Open Rated CWA Control Gear Watts Lamp Description Product No. Initial Lumens Avg. Life Hours CCT (K) Warm-Up (Min) Restrike (Min) RA Finish Oper. Pos. Fig. Case Qty 00 HIPE 00W/BU/EURO/K 99 8000 5000 000-5 0-5 68 Clear BU±5 E 6 00 HIPE 00W/C/BU/EURO/K 90 6000 5000 700-5 0-5 70 Coated BU±5 E 6 Enclosed Rated Tubular CWA Control Gear Watts Lamp Description Product No. Initial Lumens Avg. Life Hours CCT (K) Warm-Up (Min) Restrike (Min) RA Finish Oper. Pos. Fig. Case Qty 50 HIT 50W/HOR/EURO/K 577 000 0000 000-5 5-0 68 Clear HOR±5 I 00 HIT 00W/HOR/EURO/K 880 0000 5000 000-5 0-5 68 Clear HOR±5 D Enclosed Rated CWA Control Gear Watts Lamp Description Product No. Initial Lumens Avg. Life Hours CCT (K) Warm-Up (Min) Restrike (Min) RA Finish Oper. Pos. Fig. Case Qty 000 HIE 000W/U/K 609 0000V 000V 000-5 0-5 68 Clear U F 6 000 HIE 000W/C/U/K 75 05000V 000V 700-5 0-5 70 Coated U F 6 000 HIE 000W/U/BT0/K* 6 05000V 000V 000-5 0-5 68 Clear U G 6 * Reduced jacket Some lamp descriptions include the digit International Ra/CCT Code I T6 Dia. = 6mm MOL = 5mm LCL = 6mm PO A E90 Dia. = 90mm MOL = 5mm LCL = mm B E0 Dia. = 0mm MOL = 96mm LCL = 8mm C E0 Dia. = 0mm MOL = 96mm LCL = 8mm PO D T6 Dia. = 6mm MOL = 85mm LCL = 75mm PO E BT0 Dia. = 0mm MOL = 96mm LCL = 8mm F BT80 Dia. = 80mm MOL = 95mm LCL = 5mm G BT0 Dia. = 0mm MOL = 96mm LCL = 8mm H E5 Dia. = 5mm MOL = mm LCL = 89mm Base = E7 +() 085-0 Fax +() 085-0077 www.venturelightingeurope.com E-mail: sales@venturelighting.co.uk

High Wattage Lamps Features include Compact linear lamp for excellent optical control Cooler base design for improved field performance High lumen output Applications: Sports lighting Stadia Large area floodlighting Open Rated Pulse Start Reactor Control Gear Lamp Watts Description Current No. Lumens Hours (K) (Min) (Min) RA Finish Pos. Fig. Qty 875 HIPE 875W/BU/PS/70.7 87588 95000 0000+ 000-5 8-68 Clear BU±5 I 6 875 HIPE 875W/C/BU/PS/K.7 TBA 90000 0000+ 700-5 8-70 Coated BU±5 I 6 Enclosed Rated Pulse Start Reactor Control Gear Lamp Watts Description Current No. Lumens Hours (K) (Min) (Min) RA Finish Pos. Fig. Qty 875 HIE 875W/BU/PS/K.7 850 00000 0000+ 000-5 8-68 Clear BU±5 I 6 Enclosed Rated Tubular White-Lux HPS Control Gear Lamp Product Lamp Initial Avg. Life CCT Warm-Up Restrike Oper. Case Watts Description Current No. Lumens Hours (K) (Min) (Min) RA Finish Pos. Fig. Qty 000 HIT 000W/U/LU/K 0. 865 90000V 8000V 000-5 0-5 68 Clear U G 6 000 HIT000W/U/LU/5K 0. 0008 8000V 8000V 5000-5 0-5 68 Clear U G 6 Enclosed Rated Double Ended (RSC-RX7s) Reactor Control Gear Lamp Watts Description Current No. Lumens Hours (K) (Min) (Min) RA Finish Pos. Fig. Qty 000 MBIL S 000W. 7 80000H 6000H 500-5-0 68 Frosted HOR±5 A 6 500 MBIL S 500W 6.7 5 0000H 6000H 500-5-0 68 Frosted HOR±5 B 6 Lamps High Wattage Enclosed Rated Reactor Control Gear Lamp Watts Description Current No. Lumens Hours (K) (Min) (Min) RA Finish Pos. Fig. Qty 000 HIE 000W/U/K. 609 0000V 000V 000-5 0-5 68 Clear U E 6 000 HIE 000W/C/U/K. 75 05000V 000V 700-5 0-5 70 Coated U E 6 000 HIE 000W/U/BT0/K Note ➁. 6 05000V 000V 000-5 0-5 68 Clear U F 6 Enclosed Rated Tubular Reactor Control Gear Lamp Watts Description Current No. Lumens Hours (K) (Min) (Min) RA Finish Pos. Fig. Qty 000 HIT000W/U/EURO/K Note ➀ 8. 00008 90000V 8000V 000-5 0-5 68 Clear U G 6 000 HIT000W/U/EURO/5K Note ➀ 8. 008 80000V 8000V 5000-5 0-5 68 Clear U G 6 000 HIT 000W/U/K Note ➀&➃ 8.8 00066 0000V 5000V 000-5 0-5 68 Clear U H 6 000 HIT 000W/U/0V/5K Note ➀ 6.5 00067 85000V 5000V 500-5 0-5 68 Clear U H 6 000 HIT 000/U/EURO/5K Note ➀&➂ 6.5 0087 85000V 5000V 500-5 0-5 68 Clear U H 6 Enclosed Rated Double Ended (Special Base) Reactor Control Gear Lamp Watts Description Current No. Lumens Hours (K) (Min) (Min) RA Finish Pos. Fig. Qty 000 MBIL S 000W 0. 5000H 6000H 500 0 5 68 Frosted HOR±5 C Enclosed Rated Double Ended (KS-6) Reactor Control Gear Lamp Watts Description Current No. Lumens Hours (K) (Min) (Min) RA Finish Pos. Fig. Qty 000 MH-TS 000W/L/K/K 0. 80 0000H 5000H 500-5 0-5 68 Frosted HOR±5 D Some lamp descriptions include the digit International Ra/CCT Code A MBIL S E BT80 Contacts = 56mm Effective arc length = 68mm Base = RSC (RX7s)) Dia. = 80mm MOL = 95mm LCL = 5mm B MBIL S F BT0 Contacts = 56mm Effective arc length = 68mm Base = RSC (RX7s)) Dia. = 0mm MOL = 96mm LCL = 8mm C MBIL S G T76 Contacts = mm Effective arc length = 88mm Base = SINGLE CONTACT-SPECIAL Dia. = 76mm MOL = 0mm LCL = 0mm D MH-TS H T00 MOL = 70mm Nominal Arc Length = mm Base = KS-6 Dia. = 00mm MOL = 0mm LCL = 0mm I E0 Dia. = 0mm MOL = 96mm LCL = 8mm Notes Note ➀ Ignitor can be supplied with lamp Note ➁ Reduced jacket Note ➂ Low voltage ignitor only Note ➃ High voltage ignitor only +() 085-0 Fax +() 085-0077 www.venturelightingeurope.com E-mail: sales@venturelighting.co.uk

Double Ended & G Lamps Double Ended & G Enclosed Rated Single Ended (G/BiPin) HPS Reactor Gear 70 HIT 70W/G/UVS/K 598 5600V 0000V 00 - - 70 Clear U A 5 70 HIT 70W/G/UVS/K 08 5600V 0000V 000 - - 70 Clear U A 5 50 HIT 50W/G/UVS/K 5779 000V 0000V 00 - - 70 Clear U A 5 50 HIT 50W/G/UVS/K 06 000V 0000V 000 - - 70 Clear U A 5 Enclosed Rated Double Ended (RSC-RX7s) HPS Reactor Gear 70 MH-DE 70W/UVS/K 608 5500 0000 00 - - 70 Clear HOR±5 B 5 70 MH-DE 70W/UVS/K 6786 500 0000 000 - - 70 Clear HOR±5 B 5 70 MH-DE 70W/UVS/FS/6K 7970 800 0000 6500 - - 90 Clear HOR±5 B 5 50 MH-DE 50W/UVS/K 7756 50 0000 00 - - 70 Clear HOR±5 C 5 50 MH-DE 50W/UVS/K 95 50 0000 000 - - 70 Clear HOR±5 C 5 50 MH-DE 50W/UVS/FS/6K 996 50 0000 6500 - - 90 Clear HOR±5 C 5 Enclosed Rated Double Ended (Fc) Features: Compact configuration Precise optical control Long life Excellent colour uniformity Uni-Form formed body arc tube The lamps on this page feature UV Shield ultraviolet protection (70, 00 and 50 Watt) Applications: Accent lighting Downlighting Retail environments Showrooms HPS Reactor Gear 50 MH-DE 50W/K/Fc 877 0000 0000 000-5-0 70 Clear HOR±5 D 5 50 MH-DE 50W/K/Fc 778 0000 0000 00-5-0 70 Clear HOR±5 D 5 Some lamp descriptions include the digit International Ra/CCT Code A B C D G Dia. = mm MOL = 0mm LCL = 56mm Base = G MH-DE MOL =.mm Base = RSC (R7s) MH-DE MOL = mm Base = RSC (RX7s) MH-DE MOL= 6mm Base= Fc +() 085-0 Fax +() 085-0077 www.venturelightingeurope.com E-mail: sales@venturelighting.co.uk

Features: Primary colour generation - no filtration required Highly efficient - fewer fixtures required Operate on standard ballasts Compact size - good optical control Applications: Theme parks Architectural lighting Building facades Enclosed Rated Double Ended (RSC-RX7s) Lamp Op. Case Watts Description No. Colour Pos. Fig. Qty 70 MH-DE 70W/UVS/BDX 0077 Blue HOR±5 A 5 70 MH-DE 70W/UVS/GDX 0078 Green HOR±5 A 5 70 MH-DE 70W/UVS/PDX 0079 Pink HOR±5 A 5 70 MH-DE 70W/UVS/MDX 0080 Magenta HOR±5 A 5 50 MH-DE 50W/UVS/BDX 96 Blue HOR±5 B 5 50 MH-DE 50W/UVS/GDX 85 Green HOR±5 B 5 50 MH-DE 50W/UVS/PDX 008 Pink HOR±5 B 5 50 MH-DE 50W/UVS/MDX 008 Magenta HOR±5 B 5 Enclosed Rated Single Ended (G/BiPin) Lamp Op. Case Watts Description No. Colour Pos. Fig. Qty 70 HIT 70W/G/UVS/BDX 008 Blue U C 5 70 HIT 70W/G/UVS/GDX 008 Green U C 5 70 HIT 70W/G/UVS/PDX 0085 Pink U C 5 70 HIT 70W/G/UVS/MDX 0086 Magenta U C 5 50 HIT 50W/G/UVS/BDX 868 Blue U C 5 50 HIT 50W/G/UVS/GDX 6786 Green U C 5 50 HIT 50W/G/UVS/PDX 0087 Pink U C 5 50 HIT 50W/G/UVS/MDX 0088 Magenta U C 5 Designer Colour Lamps Designer Colour Enclosed Rated Single Ended (E7) Lamp Op. Case Watts Description No. Colour Pos. Fig. Qty 50 HIE 50W/U/LU/BDX 05 Blue U D 50 HIE 50W/U/LU/GDX 50 Green U D 50 HIE 50W/U/LU/PDX 0089 Pink U D 50 HIE 50W/U/LU/MDX 0090 Magenta U D Enclosed Rated Single Ended Tubular (E0) Lamp Op. Case Watts Description No. Colour Pos. Fig. Qty 50 HIT 50W/U/LU/BDX 006 Blue U E 50 HIT 50W/U/LU/GDX 006 Green U E 50 HIT 50W/U/LU/PDX 009 Pink U E 50 HIT 50W/U/LU/MDX 009 Magenta U E 00 HIT 00W/U/EURO/BDX 88 Blue U F 00 HIT 00W/U/EURO/GDX 690 Green U F 00 HIT 00W/U/EURO/PDX 975 Pink U F 00 HIT 00W/U/EURO/MDX 00 Magenta U F 00 HIT 00W/U/LU/BDX 009 Blue U F 00 HIT 00W/U/LU/GDX 000 Green U F 00 HIT 00W/U/LU/PDX 00 Pink U F 00 HIT 00W/U/LU/MDX 009 Magenta U F 000 HIT 000W/U/LU/BDX 0095 Blue U G 6 000 HIT 000W/U/LU/GDX 0096 Green U G 6 Some lamp descriptions include the digit International Ra/CCT Code A B C D E F G MH-E Contact to Contact=.mm Base = RSC (RX7s) MH-DE Contact to Contact= mm Base = RSC (RX7s) G Dia. = mm MOL = 0mm LCL = 56mm Base = G E5 Dia. = 5mm MOL = mm LCL = 89mm Base = E7 T6 Dia. = 6mm MOL = 5mm LCL = 6mm T6 Dia. = 6mm MOL = 85mm LCL = 75mm T76 Dia. = 76mm MOL = 0mm LCL = 0mm 5 +() 085-0 Fax +() 085-0077 www.venturelightingeurope.com E-mail: sales@venturelighting.co.uk

Aquatic & Special Purpose Lamps Aquatic & Special Purpose Lamps Lamps Enclosed Rated Double Ended Lamp Product Product Col. Op. Case Watts Description No. Temp. Pos. Fig. Qty 70 MH-DE 70W/6.5K 0055 6500 HOR±5 A 5 70 MH-DE 70W/0K 00 0000 HOR±5 A 5 70 MH-DE 70W/5K 0056 5000 HOR±5 A 5 70 MH-DE 70W/0K 0057 0000 HOR±5 A 5 50 MH-DE 50W/6.5K 0058 6500 HOR±5 B 5 50 MH-DE 50W/0K 00 0000 HOR±5 B 5 50 MH-DE 50W/5K 0059 5000 HOR±5 B 5 50 MH-DE 50W/0K 0060 0000 HOR±5 B 5 Enclosed Rated Double Ended Lamp Product Product Col. Op. Case Watts Description No. Temp. Pos. Fig. Qty 50 MH-DE 50W/6.5K 006 6500 HOR±5 C 5 50 MH-DE 50W/0K 005 0000 HOR±5 C 5 50 MH-DE 50W/5K 006 5000 HOR±5 C 5 50 MH-DE 50W/0K 006 0000 HOR±5 C 5 Enclosed Rated Tubular E7 Lamp Product Product Col. Op. Case Watts Description No. Temp. Pos. Fig. Qty 50 HIT 50W/6.5K 006 6500 U D 50 HIT 50W/0K 0065 0000 U D 50 HIT 50W/5K 0066 5000 U D 50 HIT 50W/0K 0067 0000 U D Enclosed Rated Tubular E0 Lamp Product Product Col. Op. Case Watts Description No. Temp. Pos. Fig. Qty 50 HIT 50W/6.5K 0068 6500 U E 50 HIT 50W/0K 006 0000 U E 50 HIT 50W/5K 0069 5000 U E 50 HIT 50W/0K 0070 0000 U E 00 HIT 00W/6.5K 007 6500 U F 00 HIT 00W/0K 007 0000 U F 00 HIT 00W/5K 007 5000 U F 00 HIT 00W/0K 007 0000 U F 000 HIT 000W/0K 007 0000 U G 6 Open Rated Lamp Product Product Col. Op. Case Watts Description No. Temp. Pos. Fig. Qty 50 HIPT 50W/0K 0075 0000 U H 00 HIPT 00W/0K 0076 0000 U I Please contact the sales office for details of suitable control gear. Some lamp descriptions include the digit International Ra/CCT Code A B C D MH-DE MOL =.mm Base = RSC (R7s) MH-DE MOL = mm Base = RSC (RX7s) MH-DE MOL= 6mm Base= Fc T8 Dia. = 8mm MOL = 56mm LCL = 0mm Base = E7 E F G H I 6 T6 Dia. = 6mm MOL = 5mm LCL = 6mm T6 Dia. = 6mm MOL = 85mm LCL = 75mm T76 Dia. = 76mm MOL = 0mm LCL = 0mm T5 Dia. = 5mm MOL = mm LCL = mm T5 Dia. = 5mm MOL = 5mm LCL = 6mm +() 085-0 Fax +() 085-0077 www.venturelightingeurope.com E-mail: sales@venturelighting.co.uk

Description Codes & Ordering Information Metal Halide Lamp Description Code: Your lamp has an imprinted code that identifies the important features you need to select a replacement. A complete explanation appears below. Lamp Description Example: HIPE 50W/C/U/LU/E90/UVS/K Lamp Type: 50 watt White-Lux Plus pulse start lamp, open luminaire rated, universal burning, coated, reduced outer jacket with UV Shield protection HIPE 50W C U LU E90 UVS K Metal halide Lamp Outer Operating White-Lux Bulb shape UV Shield Colour type wattage jacket position Plus lamp and diameter, lamp temperature finish if non-standard family Lamps LAMP DESCRIPTION CODES HIE HIPE HIPT HIT MBIL MH MH-DE MH-TS C BU V E7 or E0 European-based elliptical bulb, enclosed luminaire required E7 or E0 European-based elliptical bulb, protected arc tube for open luminaire operation E7 or E0 European-based tubular bulb, protected arc tube for open luminaire operation E0 European-based tubular bulb, arc tube for enclosed luminaire operation High wattage, double ended lamp E6 or E9 North American-based metal halide elliptical bulb, enclosed luminaire required Double-ended metal halide lamp Double-ended metal halide lamp with a fly-wire contact Lamps with a coated (diffuse) outer jacket Lamps designed for base up ( ±5 ) operating position Lamps designed for a vertical ( ±5 ) operating position H75 Lamps designed for horizontal operation ±75, HBU HO HOR EL Lamps designed for horizontal to base up operating position (or base up ±90 ) High Output Horizontal operating position Lamp optimised for Ventronic ballasts U LU EURO Universal operating position White-Lux metal halide lamp designed for use with HPS control gear Lamps designed to run on mercury reactor ballast with low pulse ignitors, usually in Europe. Euro lamps can also operate on CWA gear. See page 8-9 for more information. WLC White-Lux City metal halide lamp featuring UV Shield tubular lamps designed for horizontal operation and for use with HPS gear. E## K## T## UVS PS 7K K K 5K 6K Bulb shape (elliptical) and diameter in millimeters Spade connectors and the width of the fly-lead wire in millimeters Bulb shape (tubular) and diameter in millimeters UV Shield lamps with reduced ultraviolet output Uni-Form pulse start lamp featuring Venture s exclusive formed body arc tube designed to follow the curve of the arc stream 700K - 800K correlated colour temperature (nominal) 000K - 00K correlated colour temperature (nominal) 700K - 000K correlated colour temperature (nominal) 5000K correlated colour temperature (nominal) 6500K correlated colour temperature (nominal) CM-PLUS Ceramic Metal Halide TC Ceramic lamps with G8.5 base Positions of Operation Not Permitted Permitted Universal Any Position Vertical ±5 HOR±5 Horizontal BU ±5 Base Up HOR±5 Horizontal BU ±90 Base Up H75 Horizontal BU±05 Base Up T TD TT ED Ceramic lamps with G base Double ended ceramic lamps Tubular ceramic lamps Eliptical Ceramic lamps 7 +() 085-0 Fax +() 085-0077 www.venturelightingeurope.com E-mail: sales@venturelighting.co.uk

Ventronic Dimmable HID Control Gear Ventronic Ballasts 8 +() 085-0 Fax +() 085-0077 www.venturelightingeurope.com E-mail: sales@venturelighting.co.uk

Ventronic Dimmable HID Control Gear Introducing Ventronic from Venture Lighting, one of the world's leading names in advanced lighting design and technology. With the Ventronic solution, you can determine the light levels you require at any given time, either manually, automatically through the use of light meters or by programmable options. Saves money by making use of ambient light With conventional control gear the light is either ON or OFF. You burn full power - even when you don't need it. However, using Ventronic, the lights can be dimmed when it's bright outside, and only revert to a higher power when necessary. Ventronic can also be linked to a PIR sensor to produce more light when a particular area is occupied. Ballasts Ventronic 'Daylight Harvesting', as this technique is referred to, is an excellent way of saving energy costs and extending the life of the lamp without compromising on light levels. As it takes into consideration and therefore makes use of natural ambient light, it can also make a very positive contribution to a company's environmental policies. Ventronic Conventional Control Gear 9 +() 085-0 Fax +() 085-0077 www.venturelightingeurope.com E-mail: sales@venturelighting.co.uk

Ventronic Dimmable HID Control Gear Ventronic Ballasts Only Ventronic Offers You all These Benefits Significantly increased lumen maintenance Reduced maintenance Vastly improved lamp life Built-in diagnostics Superior light quality High reliability Exceptional energy savings High Power Factor Dimming Thermal Protection with auto reset Daylight harvesting ENEC and VDE approved Economy mode No ignitor required High efficiency No capacitor required Soft start ignition technology Ballast operates upto approximately 0 meters from lamp - No start - up current 000pF max. Controllability Simple installation with reduced costs Ventronic Models Currently Available Ventronic is available in the following wattages suitable to operate both HPS and Venture Metal Halide Pulse Start Lamps, 50W, 00W, 50W, 0W, 50W, 00W, 50W and 600W. Ordering Information As standard, Ventronic is supplied with internal dimming control switches. A communication or control option can be ordered separately. SEEP module RS85 interface Wireless communication 0 +() 085-0 Fax +() 085-0077 www.venturelightingeurope.com E-mail: sales@venturelighting.co.uk

Ventronic POD Ballasts Ventronic Thermally designed convective case. Complies with relevant sections of EN 67-. Fully EMC compliant. Can be customised to suit OEM requirements. fig 9 B L D Ventronic High Frequency Electronic Dimmable Control Gear For HPS and Venture MH Pulse Start lamps Lamp Ballast Input Circuit Running Max Case Dimensions Weight Fig Circuit Lamp (W) (A) Code Voltage Watts Current Temp (Dia x L B/Fix) (kg) Diagram Types (V) (W) (A) (tc) (mm) 00.6 VTP0055 85-5 6 0.9 90 x /55 x 90 x M5.9 9 W Venture Pulse Start and HPS Lamps 50./.0 VTP5055 85-5 70. 90 x /55 x 90 x M5.9 9 W Venture Pulse Start and HPS Lamps 0.6 VTP055 85-5 6. 90 x /55 x 90 x M5. 9 W Venture Pulse Start and HPS Lamps 50.8 VTP5055 85-5 78.6 90 x /55 x 90 x M5. 9 W Venture Pulse Start and HPS Lamps 00./.5 VTP0055 85-5.8 90 x /55 x 90 x M5. 9 W Venture Pulse Start and HPS Lamps 50.7 VTP5055 85-5 8.0 90 x /55 x 90 x M5. 9 W Venture Pulse Start and HPS Lamps 600 6. VTP60055 85-5 650.7 90 x /55 x 90 x M5.6 9 W Venture Pulse Start and HPS Lamps +() 085-0 Fax +() 085-0077 www.venturelightingeurope.com E-mail: sales@venturelighting.co.uk

Ventronic Low Wattage Ventronic Ballasts Only Ventronic Offers You all These Benefits Perfect partner for track spotlights Metal base and enclosure Ignition voltage <,5kV ENEC approval.5mm terminal block Available in 0V (on request - different dimensions) Fast start Compact and lightweight Microprocessor controlled Remote operation up to 5m Easy fixing Accepts 0.75mm to.5mm solid and stranded cable Operate stand-alone or Compatible with WiMAC 868 Output Light Levels (50%, 75%, 00%) + Off Conformally coated for moisture resistance Can be dimmable to 50% power at midnight (or other factory preset time) and if still on after 6 hours, switches back to full power Operates from a photocell Energy saving Operates Ceramic Metal Halide, Quartz Metal Halide, HPS +() 085-0 Fax +() 085-0077 www.venturelightingeurope.com E-mail: sales@venturelighting.co.uk

Ventronic HID Control Gear Ventronic Electronic Control Gear Terminal Block Versions Lamp Ballast Input Circuit Running Max Case Dimensions Weight Fig Circuit Lamp (W) (A) Code Voltage Watts Current Temp (LxWxH/Fix) (kg) Diagram Types (V) (W) (A) (tc) (mm) 0 0.5 V0MSB55 85-5 0. 80 6 x 76 x /00 x 6 0. V CMH, BritSpot 5 TBA V5MSB55 85-5 9 0. 80 6 x 76 x /00 x 6 0. V 5 0.5 V5MSB55 85-5 5 0.9 80 6 x 76 x /00 x 6 0. V CMH, CDM, HCI, ColorArc, BritSpot 50 0.76 V50MSB55 85-5 56 0. 80 6 x 76 x /00 x 6 0. V CMH, CDM, HCI, ColorArc 70.0 V70MSB55 85-5 79 0. 80 6 x 76 x /00 x 6 0. V CMH, CDM, HCI, ColorArc 00. V00SSB55 85-5 0 0.6 80 x 9 x 7/0-5 x 7-78 0.5 V CMH, CDM, HCI, SON, ColorArc 50.8 V50SSB55 85-5 6 0.67 80 x 9 x 7/0-5 x 7-78 0.5 V CMH, CDM, HCI, SON, ColorArc Ventronic Electronic Control Gear Cable Clamp Versions Lamp Ballast Input Circuit Running Max Case Dimensions Weight Fig Circuit Lamp (W) (A) Code Voltage Watts Current Temp (tc) (LxWxH/Fix) (kg) Diagram Types (V) (W) (A) (tc) (mm) 0 0.5 V0MSC55 85-5 0. 80 6 x 76 x /00 x 6 0. V CMH 5 TBA V5MSC55 85-5 9 0. 80 6 x 76 x /00 x 6 0. V 5 0.5 V5MSC55 85-5 5 0.9 80 6 x 76 x /00 x 6 0. V CMH, CDM, HCI, ColorArc 50 0.76 V50MSC55 85-5 56 0. 80 6 x 76 x /00 x 6 0. V CMH, CDM, HCI, ColorArc 70.0 V70MSC55 85-5 79 0. 80 6 x 76 x /00 x 6 0. V CMH, CDM, HCI, ColorArc 00. V00SSC55 85-5 0 0.6 80 7 x 9 x 7/7 0.5 V CMH, CDM, HCI, SON, ColorArc 50.8 V50SSC55 85-5 6 0.67 80 7 x 9 x 7/7 0.5 V CMH, CDM, HCI, SON, ColorArc Ballasts Ventronic 868 Ventronic Electronic Control Gear WiMAC Enabled Terminal Block Versions Lamp Ballast Input Circuit Running Max Case Dimensions Weight Fig Circuit Lamp (W) (A) Code Voltage Watts Current Temp (LxWxH/Fix) (kg) Diagram Types (V) (W) (A) (tc) (mm) 70.0 V70SSB55-WiMAC 85-5 79 0. 80 x 9 x 7/0-5 0. U CMH, CDM, HCI, SON, SDW-T, ColorArc 00. V00SSB55-WiMAC 85-5 0 0.6 80 x 9 x 7/0-5 0.5 U CMH, CDM, HCI, SON, SDW-T, ColorArc 50.8 V50SSB55-WiMAC 85-5 6 0.67 80 x 9 x 7/0-5 0.5 U CMH, CDM, HCI, SON, SDW-T, ColorArc Ventronic Electronic Dimmable Control Gear Part Night Terminal Block Versions Lamp Ballast Input Circuit Running Max Case Dimensions Weight Fig Circuit Lamp (W) (A) Code Voltage Watts Current Temp (LxWxH/Fix) (kg) Diagram Types (V) (W) (A) (tc) (mm) 70.0 V70SSB55-PN 85-5 79 0. 80 x 9 x 7/0-5 0. V CMH, CDM, HCI, SON, SDW-T, ColorArc 00. V00SSB55-PN 85-5 0 0.6 80 x 9 x 7/0-5 0.5 V CMH, CDM, HCI, SON, SDW-T, ColorArc 50.8 V50SSB55-PN 85-5 6 0.67 80 x 9 x 7/0-5 0.5 V CMH, CDM, HCI, SON, SDW-T, ColorArc Ventronic Electronic Dimmable Control Gear Switch Dimming Terminal Block Versions Lamp Ballast Input Circuit Running Max Case Dimensions Weight Fig Circuit Lamp (W) (A) Code Voltage Watts Current Temp (LxWxH/Fix) (kg) Diagram Types (V) (W) (A) (tc) (mm) 70.0 V70SSB55-SD 85-5 79 0. 80 x 9 x 7/0-5 0. W CMH, CDM, HCI, SON, SDW-T, ColorArc 00. V00SSB55-SD 85-5 0 0.6 80 x 9 x 7/0-5 0.5 W CMH, CDM, HCI, SON, SDW-T, ColorArc 50.8 V50SSB55-SD 85-5 6 0.67 80 x 9 x 7/0-5 0.5 W CMH, CDM, HCI, SON, SDW-T, ColorArc Ventronic High Frequency Electronic Dimmable Control Gear For HPS and Venture MH Pulse Start lamps Lamp Ballast Input Circuit Running Max Case Dimensions Weight Fig Circuit Lamp (W) (A) Code Voltage Watts Current Temp (LxWxH/Fix) (kg) Diagram Types (V) (W) (A) (tc) (mm) 00.6 VTC0055 85-5 6 0.9 90 96 x 08 x 8/0.7 9 W Venture Pulse Start and HPS Lamps 50./.0 VTC5055 85-5 70. 90 96 x 08 x 8/0.7 9 W Venture Pulse Start and HPS Lamps 0.6 VTC055 85-5 6. 90 9 x 0 x 9/. 9 W Venture Pulse Start and HPS Lamps 50.8 VTC5055 85-5 78.6 90 9 x 0 x 9/. 9 W Venture Pulse Start and HPS Lamps 00./.5 VTC0055 85-5.8 90 9 x 0 x 9/. 9 W Venture Pulse Start and HPS Lamps 50.7 VTC5055 85-5 8.0 90 9 x 0 x 9/. 9 W Venture Pulse Start and HPS Lamps 600 6. VTC60055 85-5 650.7 90 0 x 0 x 9/. 9 W Venture Pulse Start and HPS Lamps fig 9 fig fig fig W W W H H H H L L L L W For Ventronic POD details see page +() 085-0 Fax +() 085-0077 www.venturelightingeurope.com E-mail: sales@venturelighting.co.uk

Venture Parmar Ballasts Ballasts PARMAR HID control gear has been recognised for its quality and performance since the PARRY manufacturing company was formed by Mr Parry and Mr Martin (PARMAR) 60 years ago. Synonymous with bespoke and specialist control gear the Venture Parmar range of HID Control Gear can be found in highly specialist luminaries such as those used in explosive atmospheres or in road and tunnel lighting as well as conventional commercial and industrial markets. The acquisition of the PARMAR brand by Venture Lighting International in the late 990's provided the foundation to build the current extensive range of both electromagnetic and electronic HID control gear. Accommodating our Technical and Product Managers, Venture Lighting s European Technical & Distribution Centre at Castle Donington is centrally located in the UK, housing our enviably large and unmatched UK stock of lamps, ballasts, ignitors and capacitors +() 085-0 Fax +() 085-0077 www.venturelightingeurope.com E-mail: sales@venturelighting.co.uk

Ballasts With a huge product offering, boasting in excess of 500 types, Venture Lighting Europe will today supply HID ballasts of all wattages from 5W through to.5kw single voltage 50Hz through to multi voltage 50 & 60Hz with Ignitors to suit all lamp & ballast types, including timed & long distance remote mounting In support of our ballast and ignitors, we also offer a large range of PFC lighting Capacitors available in all values, both standard 50V and high voltage 0V Venture PARMAR HID control gear, high performance and quality product range, available from UK stock to support our European Lighting Industry. First Class HID control gear, second to none service and supply 5 +() 085-0 Fax +() 085-0077 www.venturelightingeurope.com E-mail: sales@venturelighting.co.uk

Ballasts The J-Range and P-Range HID Ballast Metal Halide lamps from Venture Lighting Europe are widely recognised to be the best in the world, combining technical innovation with truly outstanding performance. And to get the very best from your lamps, you need the very best control gear. J-range Ballast with the Mci Series Ignitor to offer optimum performance from all Venture Metal Halide lamps. Together, they have been optimised for maximum performance and reliability, through all wattages from 5W to 600W, offering a fully universal solution Introducing the new, high quality I-Pac Ballast and Ignitor system - combining the advanced P-range and further enhanced Scramble Winding Precision Winding The P-Range and further enhanced J-Range HID ballast group includes units rated at 5W, 50W, 70W, 00W, 50W 50W, 00W HPS & 50W, 00W HPMV. Each features an impressive, low weight design and offers a standard European footprint. Precision Wound and High Build Quality All ballasts in the range are Precision Wound to provide the best possible thermal and electrical durability. This method offers distinct advantages over the conventional Scramble or Random Wound methods. With Precision Winding, each coil is wound onto grooved insulation material, ensuring that each turn of wire is accurately positioned in parallel with each one of its neighbouring/adjacent turns of wire. A high grade of winding wire classified above 00C is always used to further enhance performance and reliability. This, coupled with Venture's intensive Vacuum Impregnation methods, guarantees the highest possible standards, and ensures the longest possible ballast life. High Grade Thermal Protection P-Range and further enhanced J-Range HID ballasts are thermally protected at 60C a value specifically chosen that will protect the ballast against any abnormal conditions and will eliminate nuisance tripping in poorly ventilated / high ambient temperature areas. Excellent Temperature Characteristics The lower wattages in the P-Range and further enchanced J-Range are as low as Delta t 60ºC. Indeed, the 00W @ 0V is only 75ºC. To compliment this further, all P-Range units are rated tw.0ºc 6 +() 085-0 Fax +() 085-0077 www.venturelightingeurope.com E-mail: sales@venturelighting.co.uk

The MCi Series Ignitor The Venture MCi Series Ignitor is a digital, intelligent timed ignitor, designed for universal operation covering 5W through to 600W. Compact Design The MCi ignitor is only 5cm in length, with a cross section of less than.5cm x.0cm - making it ideal for installations where space is at an absolute premium. Zero Watts Loss - and No Internal Temperature Rise Unlike all conventional SIP ignitors, the MCi Series ignitor does not add a single Watt of power - or a single degree of heat to your light fitting. This means a more cost and energy efficient performance, while helping to prolong the life of the unit and thus reducing maintenance requirements. A Longer Reach Remote lamp situations no longer pose any problems, as the MCi Series ignitor is designed to reliably strike a lamp up to a distance of 0 Metres. Digital Intelligence The unit has been specifically designed to offer minimum stress to all circuit components, minimum radio frequency interference combined with minimum Hot Re-Strike time. The MCi Series ignitor does not continuously pulse for 0 minutes. Whilst monitoring the circuit, an initial 5 second pulse cycle will try to strike the lamp. In the event the lamp does not strike, the pulsing will pause for minute, before repeating another 5 second pulse cycle. This process will continue until the lamp strikes, or until the 0 minutes have elapsed. By holding off the high voltage pulses in minute segments, all HID circuits and components are protected. Any radio frequency interference is kept to a bare minimum, and a hot lamp arc tube is allowed to cool much quicker, resulting in a faster hot re-strike. The timing circuit is also intelligent enough to distinguish between a cycling lamp and a mains supply interruption, allowing lamp cycles before shutting down. Component Benefits at a Glance J-range & P-Range HID ballast Covers 5W, 50W, 70W, 00W, 50W 50, 00W HPS and 50, 00W HPMV lamps Compact, lightweight design with 'European' footprint High temperature thermal protection to eliminate nuisance tripping Precision wound and using vacuum impregnation for maximum life MCi Series Ignitor Digital intelligent timed ignitor for universal operation Offers zero watts loss and no internal temperature rise 0 metre range eliminates remote lamp problems Virtually eliminates component stress and radio frequency interference Ballasts 7 +() 085-0 Fax +() 085-0077 www.venturelightingeurope.com E-mail: sales@venturelighting.co.uk

5-50W Ballasts 8 Control Gear for HPS, MH & Ceramic MH Lamps 5W & 50W 50Hz Control Gear For HPS, MH & Ceramic MH Lamps Lamp Ballast Input Circuit Running Δt/tw Dimensions Weight TC Fig Capacitor Standard Circuit Timed Circuit (W) (A) Code Voltage Watts Current ( C) LxWxH/Fix (kg) μf/v Ignitor Ignitor (V) (W) (A) (mm) 5 0.5 HSA07 0/0 8 0. 60/0 0 x 69 x 56/06- TBA Y 7 6/50 PAE0055* Y MCi6* X Note ➂ PXE07055 Y PCX07055 Y PXE0055* Y PCX0055* Y 5 0.5 HSJ07 0/0 8 0. 60/0 06 x 68 x 56/86-97.0 Y 5 6/50 PAE0055* Y MCi6* X Note ➁ PXE07055 Y PCX07055 Y PXE0055* Y PCX0055* Y 5 0.5 HSP07 0/0 8 0. 60/0 06 x 65 x 5/5 x 86-98 0.8 Y 6/50 PAE0055* Y MCi6* X PXE07055 Y PCX07055 Y PXE0055* Y PCX0055* Y 5 0.5 DG08B 0/0/0/50 8 0. 60 /0 5 x 5 x 6/-6 0.9 Y 7 6/50 PAE0055* N PCX07055 N PXE07055 N PCX0055* N PXE0055* N 50 0.76 HSA05 0/0 6 0.9 70/0 0 x 69 x 56/06-. Y 7 8/50 PAE0055* Y MCi57 X Note ➂ PXE07055 Y MCi6* X PXE0055* Y PCX07055 Y PCX0055* Y 50 0.76 HSJ05 0/0 6 0.9 70/0 06 x 68 x 56/86-97. Y 5 8/50 PAE0055* Y MCi57 X Note ➁ PXE07055 Y MCi6* X PXE0055* Y PCX07055 Y PCX0055* Y 50 0.76 HSP05 0/0 6 0.9 70/0 06 x 65 x 5/5 x 86-98 Y 8/50 PAE0055* Y MCi57 X PXE07055 Y MCi6* X PXE0055* Y PCX07055 Y PCX0055* Y 50 0.76 HSG05 0/0/0/50 65 0. 70/0 7 x 5 x 6/50-65. Y 7 8/50 PAE0055* N PCX07055 N PB070K55 A PCX0055* N PXE07055 N PJ070K55 A PXE0055* N 50 0.76 HSZ05 0/0/0/50 6 0.9 55/0 00 x 66 x 6/5 x 57-68. Y 8/50 PAE0055* N PCX07055 N PB070K55 A PCX0055* N PXE07055 N PJ070K55 A PXE0055* N 50 0.76 HSV05 0/0 6 0. 60/0 86 x 75 x 6/7 x 5. Y 9 8/50 PAE0055* F PCX07055 F Note ➀ PB070K55 G PCX0055* F PXE07055 F PJ070K55 G PXE0055* F 50/ 0.76/ HSA57 0/0 6/ 0.9/ 70/0 0 x 69 x 56/06-.6 Y 7 8/50 PAE0055* U MCi57 P 70.0 85 0.9 Note ➂ 0/50 PXE07055 U PCX07055 U PXE0055* U PCX0055* U 50/ 0.76/ HSJ57 0/0 6/ 0.9/ 70/0 06 x 68 x 56/86-97. Y 5 8/50 PAE0055* U MCi57 P 70.0 85 0.9 Note ➁ 0/50 PXE07055 U PCX07055 U PXE0055* U PCX0055* U 50/ 0.76/ HSP57 0/0 6/ 0.9/ 70/0 06 x 65 x 5/5 x 86-98. Y 8/50 PAE0055* U MCi57 P 70.0 85 0.9 0/50 PXE07055 U PCX07055 U PXE0055* U PCX0055* U 50/ 0.76/ HSG5705 0 65/ 0./ 70/0 7 x 5 x 6/50-65.5 Y 7 8/50 PAE0055* Q PCX07055 Q 70.0 86 0. 0/50 PXE07055 Q PCX0055* Q PXE0055* Q 50/ 0.76/ HSZ57 0/0 6/ 0.9/ 70/0 8 x 66 x 6/5 x 75-86.5 Y 8/50 PAE0055* U PCX07055 U 70.0 85 0.9 0/50 PXE07055 U PCX0055* U PXE0055* U 60Hz Control Gear For HPS, MH & Ceramic MH Lamps Lamp Ballast Input Circuit Running Δt/tw Dimensions Weight TC Fig Capacitor Standard Circuit Timed Circuit (W) (A) Code Voltage Watts Current ( C) LxWxH/Fix (kg) μf/v Ignitor Ignitor (V) (W) (A) (mm) 5 0.5 HSA07BD 0/0 8 0. 70/0 0 x 69 x 56/06- TBA Y 7 5/50 PAE0055* J MCi6-6* H Note ➂ PXE07055 J PCX07055 J PXE0055* J PCX0055* J 5 0.5 HSJ07BD 0/0 8 0. 70/0 06 x 68 x 56/86-97 TBA Y 5 5/50 PAE0055* J MCi6-6* H Note ➁ PXE07055 J PCX07055 J PXE0055* J PCX0055* J 5 0.5 HSP07BD 0/0 8 0. 70/0 06 x 65 x 5/5 x 86-98 0.8 Y 5/50 PAE0055* J MCi6-6* H PXE07055 J PCX07055 J PXE0055* J PCX0055* J 50 0.76 HSA05BD 0/0 6 0.9 70/0 0 x 69 x 56/06-. Y 7 7/50 PAE0055* J MCi6-6* H Note ➂ PXE07055 J PCX07055 J PXE0055* J PCX0055* J 50 0.76 HSJ05BD 0/0 6 0.9 70/0 06 x 68 x 56/86-97. Y 5 7/50 PAE0055* J MCi6-6* H Note ➁ PXE07055 J PCX07055 J PXE0055* J PCX0055* J 50 0.76 HSP05BD 0/0 6 0.9 70/0 06 x 65 x 5/5 x 86-98 Y 7/50 PAE0055* J MCi6-6* H PXE07055 J PCX07055 J PXE0055* J PCX0055* J fig fig fig 7 fig 7 fig 9 +() 085-0 Fax +() 085-0077 www.venturelightingeurope.com E-mail: sales@venturelighting.co.uk fig 5 H W L Notes Note ➀ Additional fixings 7 x mm Note ➁ Additional fixings 5 x 86-9 mm and side fixings 8-96 mm Note ➂ Additional fixings 5 x 96-09 mm and side fixings 95-09 mm * These ignitors produce.0 -.5kV and are suitable for MH lamps and some HPS and Ceramic Lamps

Control Gear for HPS, MH & Ceramic MH Lamps 70W 50Hz Control Gear For HPS, MH & Ceramic MH Lamps Lamp Ballast Input Circuit Running Δt/tw Dimensions Weight TC Fig Capacitor Standard Circuit Timed Circuit (W) (A) Code Voltage Watts Current ( C) LxWxH/Fix (kg) μf/v Ignitor Ignitor (V) (W) (A) (mm) 70.0 HSA07 0/0 86 0.9 70/0 07 x 69 x 56/86-97. Y 7 0/50 PAE0055* Y MCi57 X Note ➂ PXE07055 Y MCi6* X PXE0055* Y PCX07055 Y PCX0055* Y 70.0 HSJ07 0/0 86 0.9 70/0 06 x 68 x 56/86-97. Y 5 0/50 PAE0055* Y MCi57 X Note ➀ PXE07055 Y MCi6* X PXE0055* Y PCX07055 Y PCX0055* Y 70.0 HSP07 0/0 86 0.9 70/0 06 x 65 x 5/5 x 86-98. Y 0/50 PAE0055* Y MCi57 X PXE07055 Y MCi6* X PXE0055* Y PCX07055 Y PCX0055* Y 70.0 HSG07 0/0/0/50 86 0. 65/0 7 x 5 x 6/50-65. Y 7 0/50 PAE0055* N PCX07055 N PB070K55 A PCX0055* N PXE07055 N PJ070K55 A PXE0055* N 70.0 HSZ07 0/0/0/50 85 0.9 60/0 8 x 66 x 6/5 x 75-86. Y 0/50 PAE0055* N PCX07055 N PB070K55 A PCX0055* N PXE07055 N PJ070K55 A PXE0055* N 70.0 HSV07 0/0/0/50 87 0.9 70/0 9 x 75 x 6/5 x 5.5 Y 9 0/50 PAE0055* N PCX07055 N Note ➁ PB070K55 A PCX0055* N PXE07055 N PJ070K55 A PXE0055* N 50/ 0.76/ HSA57 0/0 6/ 0.9/ 70/0 0 x 69 x 56/06-. Y 7 8/50 PAE0055* U MCi57 P 70.0 85 0.9 Note ➃ 0/50 PXE07055 U PCX07055 U PXE0055* U PCX0055* U 50/ 0.76/ HSJ57 0/0 6/ 0.9/ 70/0 06 x 68 x 56/86-97. Y 5 8/50 PAE0055* U MCi57 P 70.0 85 0.9 Note ➀ 0/50 PXE07055 U PCX07055 U PXE0055* U PCX0055* U 50/ 0.76/ HSP57 0/0 6/ 0.9/ 70/0 06 x 65 x 5/5 x 86-98. Y 8/50 PAE0055* U MCi57 P 70.0 85 0.9 0/50 PXE07055 U PCX07055 U PXE0055* U PCX0055* U 50/ 0.76/ HSG5705 0 65/ 0./ 70/0 7 x 5 x 6/50-65.5 Y 7 8/50 PAE0055* Q PCX07055 Q 70.0 86 0. 0/50 PXE07055 Q PCX0055* Q PXE0055* Q 50/ 0.76/ HSZ57 0/0 6/ 0.9/ 70/0 8 x 66 x 6/5 x 75-86.5 Y 8/50 PAE0055* U PCX07055 U 70.0 85 0.9 0/50 PXE07055 U PCX0055* U PXE0055* U 60Hz Control Gear For HPS, MH & Ceramic MH Lamps Lamp Ballast Input Circuit Running Δt/tw Dimensions Weight TC Fig Capacitor Standard Circuit Timed Circuit (W) (A) Code Voltage Watts Current ( C) LxWxH/Fix (kg) μf/v Ignitor Ignitor (V) (W) (A) (mm) 70.0 HSA07BD 0/0 86 0.9 70/0 0 x 69 x 56/06-. Y 7 8/50 PAE0055* J MCi6-6* H Note ➂ PXE07055 J PCX07055 J PXE0055* J PCX0055* J 70.0 HSJ07BD 0/0 86 0.9 70/0 06 x 68 x 56/86-97. Y 5 8/50 PAE0055* J MCi6-6* H Note ➀ PXE07055 J PCX07055 J PXE0055* J PCX0055* J 70.0 HSP07BD 0/0 86 0.9 70/0 06 x 65 x 5/5 x 86-98. Y 8/50 PAE0055* J MCi6-6* H PXE07055 J PCX07055 J PXE0055* J PCX0055* J 70.0 HSZ076X7 0/0/0/5 85 0.9 60/0 8 x 66 x 6/5 x 75-86. Y 8/50 PAE0055* L PCX07055 L PB070K55 M PCX0055* L PXE07055 L PJ070K55 M PXE0055* L 70.0 HSZ078Y 0 (0 50Hz) 85 0.9 60/0 8 x 66 x 6/5 x 75-86. 8/50 PAE0055* K PCX07055 K PXE07055 K PCX0055* K PXE0055* K Ballasts 70W Notes Note ➀ Additional fixings 5 x 86-9 mm and side fixings 8-96 mm Note ➁ Additional fixings 5 x mm Note ➂ Additional fixings 5 x 96-09 mm and side fixings 95-09 mm Note ➃ Additional fixings 5 x 96-09 mm * These ignitors produce.0 -.5kV and are suitable for MH lamps and some HPS and Ceramic Lamps fig fig fig 7 fig 7 fig 9 fig 5 H W L 9 +() 085-0 Fax +() 085-0077 www.venturelightingeurope.com E-mail: sales@venturelighting.co.uk

00-00W Ballasts Control Gear for HPS, MH & Ceramic MH Lamps 00W 50W & 00W 50Hz Control Gear For HPS, MH & Ceramic MH Lamps Lamp Ballast Input Circuit Running Δt/tw Dimensions Weight TC Fig Capacitor Standard Circuit Timed Circuit (W) (A) Code Voltage Watts Current ( C) LxWxH/Fix (kg) μf/v Ignitor Ignitor (V) (W) (A) (mm) 00. HSA0 0/0 8 0.5 75/0 0 x 69 x 56/06-.6 Y 7 /50 PAE0055 Y MCi6 X Note ➆ PXE0055 Y PCX0055 Y 00. HSJ0 0/0 8 0.5 75/0 06 x 68 x 56/88-97. Y 5 /50 PAE0055 Y MCi6 X Note ➄ PXE0055 Y PCX0055 Y 00. HSP0 0/0 8 0.5 75/0 06 x 65 x 5/5 x 86-98. Y /50 PAE0055 Y MCi6 X PXE0055 Y PCX0055 Y 00. HSG0 0/0/0/50 0.56 75/0 7 x 5 x 6/50-65.5 Y 7 /50 PAE0055 N PCX0055 N PXE0055 N 00. HSZ0 0/0/0/50 7 0.5 60/0 8 x 66 x 6/5 x 85-96.5 Y /50 PAE0055 N PCX0055 N PXE0055 N 00. HSV0 0/0/0/50 0 0.56 75/0 9 x 75 x 6/5 x 5.5 Y 9 /50 PAE0055 N Note ➁ PXE0055 N PCX0055 N 50.8 HSA5 0/0 76 0.8 75/0 0 x 69 x 56/-. Y 7 0/50 PAE0055 Y MCi6 X Note ➇ PXE0055 Y PCX0055 Y 50.8 HSJ5 0/0 76 0.8 75/0 0 x 68 x 56/06-.8 Y 5 0/50 PAE0055 Y MCi6 X PXE0055 Y PCX0055 Y 50.8 HSP5 0/0 76 0.8 75/0 5 x 65 x 5/5 x 8-7.8 Y 0/50 PAE0055 Y MCi6 X PXE0055 Y PCX0055 Y 50.8 HSZ5 0/0/0/50 7 0.79 60/0 58 x 66 x 6/5 x 5-6. Y 0/50 PAE0055 N PCX0055 N PXE0055 N 50.8 HSV6 0/0/0/50 75 0.8 75/0 5 x 78 x 65/0. Y 9 0/50 PAE0055 N PCX0055 N PB09K55 A PJ09K55 A PXE0055 N 50.8 HSN550 00/0/0/ 67 0.7 50/0 x 08 x 09/76 x. 5 0/50 PAE0055 V PCX0055 V 0/0/50 PXE0055 V Note ➀ 50.8 HSF659 90/00/0/ 75 0.8 70/0 7 x 9 x 80/50-60. 0/50 PAE0055 T PCX0055 T 0/0/0 PB09K55 U PJ09K55 UI Note ➂ PXE0055 T 50/ 00.8 AV05 0/0 75 0.8 60/0 50 x 98 x 8/5 x 76 TBA Y 9 0/50 PAE0055 X PCX0055 X Note ➃ PXE0055 X 60Hz Control Gear For HPS, MH & Ceramic MH Lamps See Also HSN550 & HSF659 Above Lamp Ballast Input Circuit Running Δt/tw Dimensions Weight TC Fig Capacitor Standard Circuit Timed Circuit (W) (A) Code Voltage Watts Current ( C) LxWxH/Fix (kg) μf/v Ignitor Ignitor (V) (W) (A) (mm) 00. HSJ0BD 0/0 8.5 75/0 06 x 68 x 56/86-97. Y 5 0/50 PAE0055 J MCi6-6 H Note ➄ PXE0055 J PCX0055 J 00. HSP0BD 0/0 8.5 75/0 06 x 65 x 5/5 x 86-98. Y 0/50 PAE0055 J MCi6-6 H PXE0055 J PCX0055 J 50.8 HSJ5BD 0/0 76 0.8 75/0 6 x 68 x 56/-5.8 Y 5 6/50 PAE0055 J MCi6-6 H Note ➅ PXE0055 J PCX0055 J 50.8 HSP5BD 0/0 76 0.8 75/0 5 x 65 x 5/5 x 8-7.8 Y 6/50 PAE0055 J MCi6-6 H PXE0055 J PCX0055 J 50.8 HSZ665 0/0/0 75 0.8 75/0 5 x 66 x 6/5 x 85-96.8 6/50 PAE0055 A PCX0055 A PXE0055 A 0 50Hz Control Gear For MH Lamps Lamp Ballast Input Circuit Running Δt/tw Dimensions Weightl TC Fig Capacitor Standard Curcuit Timed Circuit (W) (A) Code Voltage Watts Current ( C) LxWxH/Fix (kg) μf/v Ignitor Ignitor (V) (W) (A) (mm) 00.6 HMA0 0/0 0.0 70/0 50 x 69 x 56/-. Y 7 /50 PAE0055 Y MCi6 X Note ➇ PXE0055 Y PCX0055 Y 00.6 HMJ0 0/0 0.0 70/0 6 x 68 x 56/-5 TBA Y 5 /50 PAE0055 Y MCi6 X Note ➅ PXE0055 Y PCX0055 Y 00.6 HMP0 0/0 0.0 70/0 5 x 65 x 5/5 x 8-7.9 Y /50 PAE0055 Y MCi6 X PXE0055 Y PCX0055 Y 00.6 HMZ05 0/0/0 7.0 60/0 58 x 66 x 6/5 x 5-6. /50 PAE0055 A PCX0055 A PXE0055 A 00/.6/ JH05 0/0 7/.0/ 50/0 06 x 9 x 65/80 x 90.5 Y /50 PAE0055 Y 50. Note ➃ 8.8 80/0 0/50 PXE0055 Y PCX0055 Y fig fig fig fig 5 fig 7 fig 9 fig 7 fig 9 fig fig 5 H W L Notes Note ➀ 0/0/0/50/60/70 for 60Hz Capacitor 6/TBA Note ➁ Additional fixings 5 x mm Note ➂ 0/0/0/0/50/60 for 60Hz Capacitor 6/TBA Note ➃ Suitable for step dimming to 00W Note ➄ Additional fixings 5 x 86-9 mm and side fixings 8-96 mm Note ➅ Additional fixings 5 x - 8 mm side fixings - 5 mm Note ➆ Additional fixings 5 x 96-09 mm side fixings 95-09 mm Note ➇ Additional fixings 5 x 6-9 mm side fixings 95-09 mm +() 085-0 Fax +() 085-0077 www.venturelightingeurope.com E-mail: sales@venturelighting.co.uk

Control Gear HPS, MH & Ceramic MH Lamps 50W 50Hz Control Gear For HPS, MH & Ceramic MH Lamps Lamp Ballast Input Circuit Running Δt/tw Dimensions Weight TC Fig Capacitor Standard Circuit Timed Circuit (W) (A) Code Voltage Watts Current ( C) LxWxH/Fix (kg) μf/v Ignitor Ignitor (V) (W) (A) (mm) 50.0 HSA5 0/0 86. 75/0 67 x 87 x 7/50-60.6 Y 7 0/50 PAE0055 Y MCi6 X Note ➇ PXE0055 Y PCX0055 Y 50.0 HSA5CH 0/0 86. 75/0 50 x 87 x 7/ x. Y 7 0/50 PAE0055 Y MCi6 X Note 9 PXE0055 Y PCX0055 Y 50.0 HSJ5 0/0 86. 75/0 7 x 86 x 7/6-8. Y 5 0/50 PAE0055 Y MCi6 X Note ➂ PXE0055 Y PCX0055 Y 50.0 HSP5 0/0 86. 75/0 7 x 86 x 7/08-8.8 Y 7 0/50 PAE0055 Y MCi6 X Note ➁ PXE0055 Y PCX0055 Y 50.0 HSZ5 0/0/0/50 85. 75/0 98 x 66 x 6/5 x 55-66.0 Y 0/50 PAE0055 N PCX0055 N PXE0055 N 50.0 HDV6 0/0/0/50 85. 75/0 50 x 98 x 8/5 x 76.6 Y 9 0/50 PAE0055 N PCX0055 N PB0K55 A PJ0K55 A PXE0055 N 50.0 JDV6 0/0/0/50 85. 80/0 0 x 0 x 8/90 x 00.6 Y 0/50 PAE0055 N PCX0055 N PB0K55 A PJ0K55 A PXE0055 N 50.0 EAV550 00/0/0/ 75.6 65/0 50 x 98 x 8/5 x 76. 9 0/50 PAE0055 V PCX0055 V 0/0/50 PB0K55 Z PJ0K55 Z Note ➀ PXE0055 V 50.0 HDM550 00/0/0/ 75.6 60/0 66 x 07 x 09/6 x 76 5.0 5 0/50 PAE0055 V PCX0055 V 0/0/50 PB0K55 Z PJ0K55 Z Note ➀ PXE0055 V 50.0 HDN550 00/0/0/ 75.6 60/0 x 07 x 09/ x 76.6 Y 5 0/50 PAE0055 V PCX0055 V 0/0/50 PB0K55 Z PJ0K55 Z Note ➀ PXE0055 V 50.0 HDN6 0/0/0/50 85. 70/0 x 07 x 09/ x 76.6 Y 5 0/50 PAE0055 N PCX0055 N PB0K55 A PJ0K55 A PXE0055 N 50/.0 AV55 0/0 85. 60/0 50 x 98 x 8/5 x76. Y 9 0/50 PAE0055 X 50 Note ➂ PXE0055 X PCX0055 X Ballasts 50W 60Hz Control Gear For HPS, MH & Ceramic MH Lamps See Also EAV550, HDM550 & HDN550 Above Lamp Ballast Input Circuit Running Δt/tw Dimensions Weight TC Fig Capacitor Standard Circuit Timed Circuit (W) (A) Code Voltage Watts Current ( C) LxWxH/Fix (kg) μf/v Ignitor Ignitor (V) (W) (A) (mm) 50.0 HSJ5BD 0/0 86. 75/0 7 x 86 x 7/6-8. Y 5 5/50 PAE0055 J MCi6-6 H Note ➂ PXE0055 J PCX0055 J 50.0 HSP5BD 0/0 86. 75/0 7 x 86 x 7/08-8.8 Y 7 5/50 PAE0055 J MCi6-6 H Note ➁ PXE0055 J PCX0055 J 50Hz Control Gear For MH Lamps Lamp Ballast Input Circuit Running Δt/tw Dimensions Weightl TC Fig Capacitor Standard Curcuit Timed Circuit (W) (A) Code Voltage Watts Current ( C) LxWxH/Fix (kg) μf/v Ignitor Ignitor (V) (W) (A) (mm) 50. HMA5 0/0 8.8 70/0 7 x 87 x 7/09-9. Y 7 0/50 PAE0055 Y MCi6 X Note ➆ PH00K55 B PCX0055 Y PXE0055 Y 50. HMJ5 0/0 8.8 70/0 7 x 86 x 7/96-08. Y 5 0/50 PAE0055 Y MCi6 X Note ➃ PH00K55 B PCX0055 Y PXE0055 Y 50. HMP5 0/0 8.8 70/0 7 x 86 x 7/97-06.0 Y 7 0/50 PAE0055 Y MCi6 X Note ➁ PH00K55 B PCX0055 Y PXE0055 Y 50. HMZ55 0/0/0 8.8 75/0 58 x 66 x 6/5 x 5-6. 0/50 PAE0055 A PCX0055 A PH00K55 K PXE0055 A 50. JHV6 0/0/0/50 80.5 75/0 06 x 9 x 65/80 x 90. Y 0/50 PAE0055 N PCX0055 N PB0K55 A PJ0K55 A PXE0055 N 50. MM55K0 00/0/0/ 69.8 50/0 66 x 07 x 09/6 x 76.8 5 0/50 PAE0055 V PCX0055 V 0/0/50 PH00K55 A Note ➄ PXE0055 V 50. MN55K9 90/00/0/ 69.8 55/0 x 07 x 09/ x 76. 5 0/50 PAE0055 T PCX0055 T 0/0/0 PH00K55 B Note ➅ PXE0055 T 60Hz Control Gear For HPS & MH Lamps See Also MM55K0 & MN55K9 Above Lamp Ballast Input Circuit Running Δt/tw Dimensions Weight TC Fig Capacitor Standard Curcuit Timed Circuit (W) (A) Code Voltage Watts Current ( C) LxWxH/Fix (kg) μf/v Ignitor Ignitor (V) (W) (A) (mm) 50. HMJ5BD 0/0 8.8 70/0 7 x 86 x 7/96-08. Y 5 6/50 PAE0055 J MCi6-6 H Note ➃ PH00K55 D PCX0055 J PXE0055 J 50. HMP5BD 0/0 8.8 70/0 7 x 86 x 7/97-06.0 Y 7 6/50 PAE0055 J MCi6-6 H Note ➁ PH00K55 D PCX0055 J PXE0055 J 50. HMZ565 0/0/0 8.8 75/0 58 x 66 x 6/5 x 5-6. 6/50 PAE0055 A PCX0055 A PH00K55 K Notes Note ➀ 0/0/0/50/60/70 for 60Hz Capacitor 5/TBA Note ➁ Additional fixings 66 x 06 - mm & side 96 - mm Note ➂ Additional fixings 70 x 6-5 mm side fixings 6-5 mm Note ➃ Additional fixings 70 x - 8 mm side fixings - 5 mm Note ➄ 0/0/0/50/60/70 for 6oHz Capacitor 6/TBA Note ➅ 0/0/0/0/50/60 for 60Hz Capacitor 6/TBA See page 0 for Figs Note ➆ Additional fixings 70 x 0-7 mm and side fixings 96 - mm Note ➇ Additional fixings 70 x 7-60 mm and side fixings 6-5 mm Note 9 Additional fixings 70 x 0 - mm and side fixings 9-7 mm

Control Gear for HPS, MH & Ceramic MH Lamps 00W 00W Ballasts 50Hz Control Gear For HPS, MH & Ceramic MH Lamps Lamp Ballast Input Circuit Running Δt/tw Dimensions Weight TC Fig Capacitor Standard Circuit Timed Circuit (W) (A) Code Voltage Watts Current ( C) LxWxH/Fix (kg) μf/v Ignitor Ignitor (V) (W) (A) (mm) 00.5 HAA0 0/0 5. 75/0 50 x 08 x 9/5 x 76.8 Y 5 0/50 PAE0055 Y MCi6 X Note ➄ PXE0055 Y PCX0055 Y 00.5 HSJ0 0/0 5. 75/0 67 x 86 x 7/6-58.8 Y 5 0/50 PAE0055 Y MCi6 X Note ➃ PXE0055 Y PCX0055 Y 00.5 HSP0 0/0 5. 75/0 67 x 86 x 7/8-58 Y 7 0/50 PAE0055 Y MCi6 X Note ➁ PXE0055 Y PCX0055 Y 00.5 HSV 0/0/0/50 5. 75/0 50 x 98 x 8/5 x 76. Y 9 0/50 PAE0055 N PCX0055 N PB0K55 A PJ0K55 A PXE0055 N 00.5 JAV 0/0/0/50 5. 80/0 0 x 0 x 8/90 x 00. Y 0/50 PAE0055 N PCX0055 N PB0K55 A PJ0K55 A PXE0055 N 00.5 EAV050 00/0/0/ 5. 70/0 50 x 98 x 8/5 x 76. 9 0/50 PAE0055 V PCX0055 V 0/0/50 PB0K55 Z PJ0K55 Z Note ➀ PXE0055 V 00.5 ASM050 00/0/0/ 5. 55/0 66 x 07 x 09/6 x 76 5.9 Y 5 0/50 PAE0055 V PCX0055 V 0/0/50 PB0K55 Z PJ0K55 Z Note ➀ PXE0055 V 00.5 HSM050 00/0/0/ 5. 50/0 66 x 07 x 09/6 x 76 5.9 5 0/50 PAE0055 V PCX0055 V 0/0/50 PB0K55 Z PJ0K55 Z Note ➀ PXE0055 V 00.5 HSN50 00/0/0/ 5. 65/0 x 07 x 09/ x 76 5.9 5 0/50 PAE0055 V PCX0055 V 0/0/50 PB0K55 Z PJ0K55 Z Note ➀ PXE0055 V 00.5 HSN 0/0/0/50 5. 70/0 x 07 x 09/ x 76 5.0 Y 5 0/50 PAE0055 N PCX0055 N PB0K55 A PJ0K55 A PXE0055 N 00.5 HSN59 90/00/0/ 5. 70/0 x 07 x 09/ x 76 5.0 5 0/50 PAE0055 T PCX0055 T 0/0/0 PB0K55 U PJ0K55 UI PXE0055 T 00/.5 AV50 0/0 5. 70/0 50 x 08 x 9/5 x 76 6.0 Y 8 0/50 PAE0055 X 50 Note ➂ PXE0055 X PCX0055 X 60Hz Control Gear For HPS, MH & Ceramic MH Lamps See Also EAV050, ASM050 & HSM050 Above Lamp Ballast Input Circuit Running Δt/tw Dimensions Weight TC Fig Capacitor Standard Circuit Timed Circuit (W) (A) Code Voltage Watts Current ( C) LxWxH/Fix (kg) μf/v Ignitor Ignitor (V) (W) (A) (mm) 00.5 HAA0BD 0/0 5. 75/0 50 x 08 x 9/5 x 76.6 Y 5 5/50 PAE0055 J MCi6-6 H Note ➄ PXE0055 J PCX0055 J 00.5 HSJ0BD 0/0 5. 75/0 67 x 86 x 7/6-58.8 Y 5 5/50 PAE0055 J MCi6-6 H Note ➃ PXE0055 J PCX0055 J 00.5 HSP0BD 0/0 5. 75/0 67 x 86 x 7/8-58 Y 7 5/50 PAE0055 J MCi6-6 H Note ➁ PXE0055 J PCX0055 J NOTES Note ➀ 0/0/0/50/60/70 for 60Hz Capacitor 5/TBA Note ➁ Additional fixings 66 x 8-5 & side 9-5 mm Note ➂ Suitable for step dimming to 50W Note ➃ Additional fixings 70 x 6-55 mm side fixing 6-55 mm Note ➄ Additional side fixings - 9 mm fig fig fig 5 fig 8 fig 9 fig 7 fig 5 H W L +() 085-0 Fax +() 085-0077 www.venturelightingeurope.com E-mail: sales@venturelighting.co.uk

Control Gear for MH & Ceramic MH Lamps 50W 00W & 50W 50Hz Control Gear For MH Lamps Lamp Ballast Input Circuit Running Δt/tw Dimensions Weight TC Fig Capacitor Standard Circuit Timed Circuit (W) (A) Code Voltage Watts Current ( C) LxWxH/Fix (kg) μf/v Ignitor Ignitor (V) (W) (A) (mm) 50.8 HMA5 0/0 77.8 70/0 67 x 87 x 7/50-60. Y 5 0/50 PAE0055 Y MCi6 X Note ➆ PXE0055 Y PCX0055 Y 50.8 HMJ5 0/0 77.8 70/0 7 x 86 x 7/6-8 Y 5 0/50 PAE0055 Y MCi6 X Note ➀ PXE0055 Y PCX0055 Y 50.8 HMP5 0/0 77.8 70/0 7 x 86 x 7/8-8.7 Y 7 0/50 PAE0055 Y MCi6 X Note ➄ PXE0055 Y PCX0055 Y 50.8 JHV55 0/0/0 7.8 65/0 0 x 0 x 8/90 x 00.5 0/50 PAE0055 N PCX0055 N PXE0055 N 50/.8/ JH505 0 7/.8/ 60/0 0 x 0 x 8/90 x 00 TBA 0/50 PAE0055 E 00.5 Note ➂ 0.0 70/0 5/50 PXE0055 E PCX0055 E 00.5 HMA0 0/0 0.0 75/0 67 x 87 x 7/50-60. Y 5 5/50 PAE0055 Y MCi6 X Note ➆ PH00K55 B PCX005 Y PXE0055 Y 00.5 HMA0CH 0/0 0.0 75/0 50 x 86 x 7/-.5 Y 5 5/50 PAE0055 Y MCi6 X Note ➇ PH00K55 B PCX005 Y PXE0055 Y 00.5 HMJ0 0/0 0.0 75/0 7 x 86 x 7/6-8. Y 5 5/50 PAE0055 Y MCi6 X Note ➀ PH00K55 B PCX005 Y PXE0055 Y 00.5 HMP0 0/0 0.0 75/0 7 x 86 x 7/8-8.8 Y 7 5/50 PAE0055 Y MCi6 X Note ➄ PH00K55 B PCX005 Y PXE0055 Y 00.5 HMZ05 0/0/0 0.0 70/0 98 x 66 x 6/5 x 55-66. 5/50 PAE0055 A PCX0055 A PH00K55 K PXE0055 A 00.5 JHVB 0/0/0 0.0 80/0 0 x 0 x 8/90 x 00.8 Y 5/50 PAE0055 A PCX0055 A PH00K55 K PXE0055 A 00.5 EMV050 00/0/0/ 5.9 75/0 50 x 98 x 8/5 x 76.8 9 5/50 PAE0055 V PCX0055 V 0/0/50 PB0K55 Z PJ0K55 Z Note ➅ PH00K55 A PXE0055 V 00.5 MM05K0 00/0/0/ 5.9 60/0 66 x 07 x 09/6 x 76 5. 5 5/50 PAE0055 V PCX0055 V 0/0/50 PH00K55 A Note ➅ PXE0055 V Ballasts 50-50W 60Hz Control Gear For MH Lamps See Also EMV050 & MM05K0 Above Lamp Ballast Input Circuit Running Δt/tw Dimensions Weight TC Fig Capacitor Standard Circuit Timed Circuit (W) (A) Code Voltage Watts Current ( C) LxWxH/Fix (kg) μf/v Ignitor Ignitor (V) (W) (A) (mm) 00.5 HMA0BD 0/0 0.0 75/0 67 x 87 x 7/50-60 Y 5 0/50 PAE0055 J MCi6-6 H Note ➆ PH00K55 D PCX0055 J PXE0055 J 00.5 HMJ0BD 0/0 0.0 75/0 7 x 86 x 7/6-8. Y 5 0/50 PAE0055 J MCi6-6 H Note ➀ PH00K55 D PCX0055 J PXE0055 J 00.5 HMP0BD 0/0 0.0 75/0 7 x 86 x 7/8-8.8 Y 7 0/50 PAE0055 J MCi6-6 H Note ➄ PH00K55 D PCX0055 J PXE0055 J 50Hz Control Gear For MH Lamps Lamp Ballast Input Circuit Running Δt/tw Dimensions Weight TC Fig Capacitor Standard Circuit Timed Circuit (W) (A) Code Voltage Watts Current ( C) LxWxH/Fix (kg) μf/v Ignitor Ignitor (V) (W) (A) (mm) 50.7 HAA0 0/0 77.8 75/0 50 x 08 x 9/5 x 76 6.0 Y 5 5/50 PAE0055 Y MCi6 X Note 9 PXE0055 Y PCX0055 Y 50.7 HSJ0 0/0 77.8 75/0 67 x 86 x 7/6-58.8 Y 5 5/50 PAE0055 Y MCi6 X Note ➃ PXE0055 Y PCX0055 Y 50.7 HSP0 0/0 77.8 75/0 67 x 86 x 7/8-58.0 Y 7 5/50 PAE0055 Y MCi6 X Note ➁ PXE0055 Y PCX0055 Y fig fig fig 5 fig 8 fig 9 fig 7 fig 5 H W L NOTES Note ➀ Additional fixings 70 x 6-5 mm side fixings 6-5 mm Note ➁ Additional fixings 66 x 8-5 mm & side 9-5 mm Note ➂ 50W ballast with additional tapping for 00W lamps Note ➃ Additional fixings 70 x 6-55 mm side fixing 6-55 mm Note ➄ Additional fixings 66 x 6 - mm & side 06 - mm Note ➅ 0/0/0/50/60/70 for 60Hz Capacitor 0/TBA Note ➆Additional fixings 70 x 7-60 mm and side fixings 6-5 mm Note ➇Additional fixings 70 x 6-0 mm and side fixings 9-7 mm Note 9Additional side fixings - 9 mm +() 085-0 Fax +() 085-0077 www.venturelightingeurope.com E-mail: sales@venturelighting.co.uk

600-000W Ballasts Control Gear for HPS, MH Lamps 600W 875W 000W 500W & 000W 50Hz Control Gear For HPS & MH Lamps Lamp Ballast Input Circuit Running Δt/tw Dimensions Weight TC Fig Capacitor Standard Circuit Timed Circuit (W) (A) Code Voltage Watts Current ( C) LxWxH/Fix (kg) μf/v Ignitor Ignitor (V) (W) (A) (mm) 600 6. HAA60 0/0 655.89 80/0 77 x 08 x 9/56 x 6 7.0 Y 60/50 PXE00055 Y MCi-600 X PCX00055 Y 600 6. HAV60 0/0 655.89 80/0 50 x 08 x 9/5 x 76 6.0 Y 60/50 PXE00055 Y MCi-600 X Note ➁ PCX00055 Y 600 6. HAV60B 0/0/0 655.89 80/0 50 x 08 x 9/5 x 76 6.0 Y 8 60/50 PXE00055 A PCX00055 A 600 6. HAV60 0/0 655.89 80/0 50 x 08 x 9/5 x 76 6.0 60/50 PXE00055 Y MCi-600 X PCX00055 Y 600 6. HSM6050 00/0/0/ 655. 75/0 66 x 07 x 09/6 x 76 7.6 5 60/50 PB600K55 F PCX00055 V 0/0/50 PXE00055 V PJ600K55 Z Note ➀ 875.7 SHQ877 0/0 970.5 90/0 x 08 x 00/ x 98 - - 6/500 BVS-00 See Datasheet 875/.7/. HMP808 80/00/5 95/00.5/.0 75/0 90 x 0 x 05/66 x 0 0 6 5/0 PXE5085 See Datasheet 000 000 0. HDP00 0/0 05 5.0 80/0 90 x 0 x 0/0 x 55-77 9. 6 x 50/50 PXE00055 Q PCX00055 Q Note ➄ MCi-000 Z 000 0. HDP00 0/0/0/0 05 5.0 80/0 90 x 0 x 0/0 x 55-77 9. 6 x 50/50 PXE00055 Q PCX00055 Q Note ➄ 000 0. HDV00 0/0/0/0 05 5.0 80/0 77 x 50 x 6/8 x 5 0.8 6 x 50/50 PB000K55 R PCX00055 Q PXE00055 Q PJ000K55 S 000 0. HSV00 0/0/0/50 090 5. 60/0 5 x 50 x 6/80 x 5 5.5 6 x 50/50 PB000K55 J PCX00055 N PXE00055 N PJ000K55 A 000 0. HDF005 0/0/0 05 5.0 65/0 00 x 60 x 0/80 x 5.0 x 50/50 PXE00055 A PCX00055 A 000 5.7 HSV08 80/00/5 090 60/0 5 x 50 x 6/80 x 5 6.5 6 0/0 PB500K5 T N/A PXE5085 B 000 5.7 HSV08 80/5/0 090 60/0 5 x 50 x 6/80 x 5 6.5 6 0/0 PB500K5 L N/A PXE5085 M 000 5.7 HSV005AD 00 090 60/0 5 x 50 x 6/80 x 5 6.5 6 0/0 PXE5085 K N/A Note ➂ 000 8. HIB005 0/0/0 080 5. 65/0 x 0 x /0 x 76.0 5 x 5/50 PH00K55 K N/A PXE00055 A 000 8. HQV00 0/0 080 5. 65/0 77 x 50 x 6/8 x 5 0.8 6 x 5/50 PB000K55 G PJ000K55 G PH00K55 H PXE00055 F 000./. HMM08 80/00/5 05.7 70/0 66 x 07 x 09/6 x 76 7.6 5 5/0 PBA0085 L PB500K5 T PCT5085 D PT50K5 B PXE5085 B 000. YHB005 0 090 5.5 75/0 0 x 0 x /0 x 76 5.0 Y 5 5/0V PBA0085 V PCT5085 D Note ➃ PT50K5 M 500 6.7 HMV08 80/00/5 580.77 60/0 5 x 50 x 6/80 x 5 5.0 6 0/0 PBA0085 L PCT5085 D PT50K5 B 000 6.5 HMV9 0/0/0/50 05 9.9 75/0 5 x 50 x 6/80 x 5 6.5 6 x 50/50 PH00K55 N N/A PBE9005 N 000 8.8 HMV98 80/00/5 085 5.6 65/0 5 x 50 x 6/80 x 5 6.5 6 0/0 PBA0085 L PCX5085 B PB500K5 T PXE5085 B 000 0. HZP98V 80/00/5/0 05 6 75/0 77 x x 0/50-6 5.8 5/0 PB500K5 C PCX5085 B Note ➄ PT50K5 D PCT5085 D PXE5085 D 000 0. HZV98 80/00/5 05 6 75/0 5 x 50 x 6/80 x 5 6.5 6 5/0 PB500K5 T PCX5085 B PT50K5 B PCT5085 D PXE5085 B 000 0. HZV98V 80/00/5/0 05 6 75/0 5 x 50 x 6/80 x 5 6.5 6 5/0 PB500K5 C PCX5085 B PT50K5 D PCT5085 D PXE5085 D 60Hz Control Gear For HPS & MH Lamps See Also HSM6050 & HSV005AD Above Lamp Ballast Input Circuit Running Δt/tw Dimensions Weight TC Fig Capacitor Standard Circuit Timed Circuit (W) (A) Code Voltage Watts Current ( C) LxWxH/Fix (kg) μf/v Ignitor Ignitor (V) (W) (A) (mm) 600 6. HAV60BD 0/0 655.89 80/0 50 x 08 x 9/5 x 76 Note ➁ 6.0 Y 50/50 PXE00055 J MCi6-6 H 000 0. HDV0065 0/0/0 05 5.0 80/0 77 x 50 x 6/8 x 5 0.8 6 x 0/50 PXE00055 A N/A 000 6.5 HMV9E6 0/0/0/50 05 9.9 75/0 5 x 50 x 6/80 x 5 6.5 6 x 0/50 PH00K55 N N/A PBE90055 N 000 0. HZV906 0 05 6 75/0 5 x 50 x 6/80 x 5 6.5 6 0/0 PT50K5 P PCT5085 D PXE5085 P Notes Note ➀ 0/0/0/50/60/70 for 60Hz Capacitor 50/TBA Note ➁ Additional side fixings - 9 mm Note ➂ 80V 60Hz Capacitor 5/TBA Note ➃ Essential Capacitor Note ➄Additional fixings 0 x - 6 mm fig fig fig fig 5 fig 6 fig 7 fig 8 fig 9 fig 5 fig 6 fig 7 fig fig fig fig fig 5 W H L

Control Gear for Mercury Lamps /SOX Lamps 50W - 000W /5W - 5W 50Hz Control Gear For Mercury Lamps Lamp Ballast Input Circuit Running Δt/tw Dimensions Weight TC Fig Capacitor Standard Circuit Timed Circuit (W) (A) Code Voltage Watts Current ( C) LxWxH/Fix (kg) μf/v Ignitor Ignitor (V) (W) (A) (mm) 50 0.6 MP05K 0/0 6 0.9 65/0 06 x 65 x 5/5 x 86-98 0.7 6/50 N/A Z N/A 50 0.6 MG05K5 0/0/0 6 0.0 65/0 7 x 5 x 6/50-65 0.9 7 6/50 N/A G N/A 50 0.6 MZ05K5 0/0/0 6 0.9 60/0 00 x 66 x 6/5 x 57-68 0.9 6/50 N/A G N/A 80 0.8 MP08K 0/0 95 0. 65/0 06 x 65 x 5/5 x 86-98.0 8/50 N/A Z N/A 80 0.8 MG08K5 0/0/0 96 0. 75/0 7 x 5 x 6/50-65.0 7 8/50 N/A G N/A 80 0.8 MZ08K5 0/0/0 9 0. 55/0 00 x 66 x 6/5 x 57-68.0 8/50 N/A G N/A 5.5 MP7K 0/0 0.65 70/0 06 x 65 x 5/5 x 86-98. 0/50 N/A Z N/A 5.5 MG8B5 0/0/0 5 0.66 75/0 5 x 5 x 6/-6. 7 0/50 N/A G N/A 5.5 MZ8K5 0/0/0 0.65 60/0 8 x 66 x 6/5 x 75-86. 0/50 N/A G N/A 50. HMJ5 0/0 8.8 70/0 7 x 86 x 7/96-08 Note ➆. Y 5 0/50 N/A Z N/A 50. HMP5 0/0 8.8 70/0 7 x 86 x 7/97-06 Note ➁.0 Y 0/50 N/A Z N/A 50. HMZ55 0/0/0 8.8 75/0 58 x 66 x 6/5 x 5-6. 0/50 N/A G N/A 50. JHV6 0/0/0/50 80.5 75/0 06 x 9 x 65/80 x 90. Y 0/50 N/A W N/A 50. MM55K0 00/0/0/ 69.8 50/0 66 x 07 x 09/6 x 76.8 5 0/50 N/A Q N/A 0/0/50 Note ➀ 50. MN55K9 90/00/0/ 69.8 55/0 x 07 x 09/ x 76. 5 0/50 N/A S N/A 0/0/0 Note ➂ 00.5 HMJ0 0/0 0.0 75/0 7 x 86x 7/6-8 Note ➇. Y 5 5/50 N/A Z N/A 00.5 HMP0 0/0 0.0 75/0 7 x 86 x 7/8-8 Note ➃.8 Y 7 5/50 N/A Z N/A 00.5 HMZ05 0/0/0 0.0 70/0 98 x 66 x 6/5 x 55-66. 5/50 N/A G N/A 00.5 JHVB 0/0/0 0.0 80/0 0 x 0 x 8/90 x 00.8 Y 5/50 N/A G N/A 00.5 EMV050 00/0/0/ 5.9 75/0 50 x 98 x 8/5 x 76.8 9 5/50 N/A Q N/A 0/0/50 Note ➄ 00.5 MM05K0 00/0/0/ 5.9 60/0 66 x 07 x 09/6 x 76 5. 5 5/50 N/A Q N/A 0/0/50 Note ➄ 000 7.5 MM00K 0/0/0/50 00 5.0 75/0 66 x 07 x 09/6 x 76 7.6 5 50/50 N/A U N/A 000. HMM08 80/00/5 05.7 70/0 66 x 07 x 09/6 x 76 7.6 5 5/0 N/A H N/A Control Gear For Sox lamps Lamp Ballast Input Circuit Running Δt/tw Dimensions Weight TC Fig Capacitor Standard Circuit Timed Circuit (W) (A) Code Voltage Watts Current ( C) LxWxH/Fix (kg) μf/v Ignitor Ignitor (V) (W) (A) (mm) 5 0.6 RSM055 0 50 0. 5 ta 65 x 60 x 8/5.8 6 8/50 Integral E N/A N/A 5/ 0.6/ SZ55K5 0 8/ 0./ 70/0 8 x 66 x 6/5 x 75-86.0 8/50 55 0.59 68 0. 6/50 PB05K5 C PB055K5 C 5/ 0.6/ SG55B5 0 50/ 0./ 60/0 5 x 5 x 6/-6 0.8 7 8/50 55 0.59 69 0. 6/50 PB05K5 C PB055K5 C 5/ 0.6/ RSD555 0 50/ 0./ 50 ta x 65 x 5/0. 8/50 55 0.59 69 0. 6/50 N/A Integral S 5/ 0.6/ RSF555 0 50/ 0./ 70 tc 59 x 50 x 67/6.8 5 8/50 N/A Integral D 55 0.59 69 0. 6/50 5/ 0.6/ RSL555 0 50/ 0./ 5 tc 65 x 76 x 5/5.0 6 8/50 N/A Integral E 55 0.59 69 0. 6/50 90 0.9 SZ090K5 0 0 0.8 65/0 8 x 66 x 6/5 x 75-86. 8/50 N/A PB090K5 C 90 0.9 SG090B5 0 05 0.9 65/0 5 x 5 x 6/-6. 7 8/50 N/A PB090K5 C 90 0.9 RSL0905 0 06 0.9 5 ta 65 x 76 x 5/5. 6 8/50 N/A Integral E 90 0.9 SL09K 0/0/0/50 5 0.58 65/0 78 x 99 x 7/6.8 6 5/50 N/A R N/A 5 0.95 RSA55 0 75 0.88 5 ta x 76 x 59/0.9 6 0/50 Integral E N/A 5/ 0.95/ SM8K 0/0/0/50 75/ 0.8/ 80 0.9 5.0 70/0 66 x 07 x 09/6 x 76 7. 5 5/0 Note ➅ N/A F N/A Ballasts Control Gear for Mercury & SOX Lamps See page for Figs Notes Note ➀ 0/0/0/50/60/70 for 60Hz Capacitor 6/TBA Note ➁ Additional fixings 66 x 06 - mm & side 96 - mm Note ➂ 0/0/0/0/50/60 for 60Hz Capacitor 6/TBA Note ➃ Additional fixings 66 x 6 - & side 06 - mm Note ➄ 0/0/0/50/60/70 for 60Hz Capacitor 0/TBA Note ➅ Essential Capacitor Note ➆ Additional fixings 5 x - 8 mm side fixings - 5 mm Note ➇ Additional fixings 70 x 6-5 mm side fixings 6-5 mm (ta) Maximum Ambient temperature (tc) Maximum Case temperature 5 +() 085-0 Fax +() 085-0077 www.venturelightingeurope.com E-mail: sales@venturelighting.co.uk

CWA, MH, Other & Auto Transformers Ballasts Control Gear for CWA,MH, Other Lamps, Lamp Detecting Device & Auto transformers Control Gear For CWA MH Lamps Lamp Ballast Input Circuit Running Δt/tw Dimensions Weight TC Fig Capacitor Standard Circuit Timed Circuit (W) (A) Code Voltage Watts Current ( C) LxWxH/Fix (kg) μf/v Ignitor Ignitor (V) (W) (A) (mm) 75.5 HMZ785 0/0/0 97 0.9 55/0 7 x 66 x 6/5 x 8-6. 0/50 PAE0055 A PCX0055 A PH00K55 K 50. SHQ505 0 89.9 80/0 50 x 9 x 0/6 x 5.75 7.5/50 N/A See Datasheet 00.5 SHQ005 0 55.5 80/0 50 x 00 x 0/77 x 5.75 8/50 N/A See Datasheet 00.5 SHW05 0/0/0 65.0 85/0 59 x 8 x 9/5 x 99 7.5 5/0 Note ➃ N/A J N/A Special Control Gear for IWASAKI Lamps & Cold Cathode Lamps Lamp Ballast Input Circuit Running Δt/tw Dimensions Weight TC Fig Capacitor Standard Circuit Timed Circuit (W) (A) Code Voltage Watts Current ( C) LxWxH/Fix (kg) μf/v Ignitor Ignitor (V) (W) (A) (mm) 00.5 AIZ0005 Note ➀ 00 6.0 65/0 8 x 66 x 6/5 x 85-96.6 0/50 Note ➃ PIE5005 N N/A 00.5 YAZ005 0 0 0. 60/0 98 x 66 x 6/5 x 55-66. Y 8 0/50 Note ➃ PIE5005 P N/A 50.9 AIZ5005 00 66.0 75/0 7 X 66 X 6/5 X 5-6.8 5/50 PIE5005 C N/A Note ➁ 50.9 YAZ505 0 7 0.78 70/0 5 x 66 x 6/5 x 55-66. Y 8 5/50 Note ➃ PIE5005 P N/A N/A 0.5 CGN50850 0 N/A N/A N/A 85 x 0 x 78/65 x 76 5 5 - N/A R N/A Lamp Detecting Device AuxilaryLamp Product Input Circuit Running Δt/tw Dimensions Weight TC Fig Max Ignition Internal Circuit (W) (A max) Code Voltage Watts Current ( C) Ø x L/Fix (kg) Pulse Temperature (V) (W) (A) (mm) (kv) ( C) 50-500. LDD50055 0 - - 85tc 5 x 0/ M8 x 0 0.5-6 5.0 5 T Note ➄ Auto Transformers VA Product Voltage Dimension Weight Thermal Fig Code Input - Output LxWxH/Fix (kg) Cut-out (V) (mm) 0 XNG00J8 0/0-0 9 x 5 x 6/76 x 86 0.5 7 0 XNZ000M 0/0/ 00 x 66 x 6/5 x 57-68 0. Y 0-00 00 XCG000 00-0 7 x 5 x 6/50-65.5 7 00 XCZ000 0-00 00 x 66 x 6/5 x 57-68 0.5 Y 500 XEM00 0-0 66 x 07 x 09/6 x 76 5. Y 5 500 XEM00 0-0 66 x 07 x 096 x 76 5. 5 500 XEN800 80/80-0 x 07 x 09 x 76.8 Y 5 500 XEV00AR 0-0 50 x 98 x 8/5 x 76.6 Y Note ➂ 9 500 XEV00 0-0 50 x 98 x 8/5 x 76.6 9 500 XEV00 0-0 50 x 98 x 8/5 x 76.6 9 50 XFM00 0-0 66 x 07 x 09/6 x 76 9.5 5 50 XFM05 0-5 66 x 07 x 09/6 x 76 7.5 5 50 XFV00AR 0-0 58 x 98 x /5 x 76 8. Y Note ➂ 6 500 XGV800 80-0 5 x 50 x 6/80 x 5 5.5 6 All transformers are designed to operate with suitable power factor correction capacitors in circuit fig fig fig 5 fig 6 Note ➃ Notes Note ➀ For use with XNZ000M Transformer Note ➁ For use with XCZ000 Transformer Note ➂ Non resetting thermal cutout fitted Note ➃ Essential Capacitor Note ➄ Other Circuits on Request (tc) Maximum Case temperature fig 7 fig 9 fig 8 fig 6 fig 6 W 6 H L +() 085-0 Fax +() 085-0077 www.venturelightingeurope.com E-mail: sales@venturelighting.co.uk

High Power Factor Conversion Kits 00w Resin Filled with Ignitor and Capacitor Part No Fitting Type Kit Description Ballast Ignitor Capacitor Lamp Fig IBM-00WCONKIT-007 Open rated HIPT 00W/H75/UVS/T5/PS/K KIT IBM005CU INT INT 007 8 IBM-00WCONKIT-0085 Enclosed rated HIT 00W/H75/PS/K KIT IBM005CU INT INT 0085 8 IBM-00WCONKIT-0058 Enclosed rated HIE 00W/C/U/PS/K KIT IBM005CU INT INT 0058 8 IBM-00WCONKIT-0059 Open rated HIPE 00W/C/V/UVS/PS/K KIT IBM005CU INT INT 0059 8 IMB-00WCONKIT-0067 Open rated HIPE 00W/V/PS/K KIT IBM005CU INT INT 0067 8 IBM-00WCONKIT-887 Enclosed rated HIE 00W/U/PS/K KIT IBM005CU INT INT 887 8 00w Magnetic Loose Gear Part No Fitting Type Kit Description Ballast Ignitor Capacitor Lamp Fig 00WCONKIT-007 Open rated HIPT 00W/H75/UVS/T5/PS/K KIT HMP0 MCi6 R008HP0P5 007 00WCONKIT-0085 Enclosed rated HIT 00W/H75/PS/K KIT HMP0 MCi6 R008HP0P5 0085 00WCONKIT-0058 Enclosed rated HIE 00W/C/U/PS/K KIT HMP0 MCi6 R008HP0P5 0058 00WCONKIT-0059 Open rated HIPE 00W/C/V/UVS/PS/K KIT HMP0 MCi6 R008HP0P5 0059 00WCONKIT-0067 Open rated HIPE 00W/V/PS/K KIT HMP0 MCi6 R008HP0P5 0067 00WCONKIT-887 Enclosed rated HIE 00W/U/PS/K KIT HMP0 MCi6 R008HP0P5 887 50w Resin Filled with Internal Ignitor and Capacitor Part No Fitting Type Kit Description Ballast Ignitor Capacitor Lamp Fig IBM-50WCONKIT-008 Open rated HIPT 50W/H75/UVS/T5/PS/K KIT IBM505CU INT INT 008 8 IBM-50WCONKIT-008 Enclosed rated HIT 50W/H75/PS/K KIT IBM505CU INT INT 008 8 IBM-50WCONKIT-0056 Enclosed rated HIE 50W/C/V/PS/K KIT IBM505CU INT INT 0056 8 IBM-50WCONKIT-0057 Open rated HIPE 50W/C/V/PS/K KIT IBM505CU INT INT 0057 8 IBM-50WCONKIT-0068 Open rated HIPE 50W/V/PS/K KIT IBM505CU INT INT 0068 8 IBM-50WCONKIT-9607 Enclosed rated HIE 50W/H75/PS/K KIT IBM505CU INT INT 9607 8 IBM-50WCONKIT-08 Enclosed rated HIE 50W/V/PS/K KIT IBM505CU INT INT 08 8 50w Magnetic Loose Gear Part No Fitting Type Kit Description Ballast Ignitor Capacitor Lamp Fig Ballasts Conversion Kits 50WCONKIT-008 Open rated HIPT 50W/H75/UVS/T5/PS/K KIT HMP5 MCi6 R008HP00P5M 008 7 50WCONKIT-008 Enclosed rated HIT 50W/H75/PS/K KIT HMP5 MCi6 R008HP00P5M 008 7 50WCONKIT-0056 Enclosed rated HIE 50W/C/V/PS/K KIT HMP5 MCi6 R008HP00P5M 0056 7 50WCONKIT-0057 Open rated HIPE 50W/C/V/PS/K KIT HMP5 MCi6 R008HP00P5M 0057 7 50WCONKIT-0068 Open rated HIPE 50W/V/PS/K KIT HMP5 MCi6 R008HP00P5M 0068 7 50WCONKIT-9607 Enclosed rated HIE 50W/H75/PS/K KIT HMP5 MCi6 R008HP00P5M 9607 7 50WCONKIT-08 Enclosed rated HIE 50W/V/PS/K KIT HMP5 MCi6 R008HP00P5M 08 7 fig fig 7 fig 8 7 +() 085-0 Fax +() 085-0077 www.venturelightingeurope.com E-mail: sales@venturelighting.co.uk

Ignitors Ignitors Ballasts Wattage Ignitor Timed Ignitor Max Lamp Pulse Dimensions FIxing Weight Max. Lead Max Case Internal Fig (W) Code Type Current Magnitude Ø/LxWxH (kg) Capacitance Temp Temp (A) (kv) (mm) (pf) ( C) ( C) MCi Series Ignitors 0/0V ±0% 50Hz 5-600 MCi6 Y Semi-Parallel N/A.0-.5 50 x 5 x 7 M8 x 0 0.08 000 Note ➁ 05 N/A 50/70 MCi57 Y Semi-Parallel N/A.8-.5 50 x 5 x 7 M8 x 0 0.08 00 05 N/A 600 MCi-600 Y Semi-Parallel N/A.0-5.0 50 x 5 x 7 M8 x 0 0.08 000 05 N/A 000 MCi-000 Y Semi-Parallel N/A.0-5.0 9 x 7 M8 x 0 0. 0000 05 N/A MCi Series Ignitors 0/0V ±0% 60Hz 5-600 MCi6-6 Y Semi-Parallel N/A.0-.5 50 x 5 x 7 M8 x 0 0.08 000 05 N/A Standard Ignitors 0/0V ±0% 50/60Hz 5-70 PXE07055 N Superimposed.8-. 7 x x M8 x 0 0.8 00 90 0 0 5-50 PXE0055 N Superimposed 5.5-.5 7 x x M8 x 0 0.8 00 05 0 0 5-50 PAE0055 N Superimposed 5.5-.5 9 x 7 M8 x 0 0.8 00 05 0 5-50 PLE0055 N Superimposed 5.0-.5 7 x 50 M8 x 0 0.5 000 90 0 600-000 PXE00055 N Superimposed.5-5.0 90 x 9 x 50 M8 x 0 0.5 00 05 5 0 000 PBE9005 N Superimposed 8.0-.5 6 x M x 0.9 00 90 0 50-70 PB070K55 N Impulser N/A.8-. 9 x 7 M8 x 0 0. 500 85 N/A 50 PB09K55 N Impulser N/A.0-.5 9 x 7 M8 x 0 0. 000 85 N/A 50-00 PB0K55 N Impulser N/A.0-.5 9 x 7 M8 x 0 0. 000 85 N/A 600 PB600K55 N Impulser N/A.0-.5 5 x 5 M8 x 0 0.8 000 85 N/A 000 PB000K55 N Impulser N/A.0-.5 5 x 5 M8 x 0 0.8 5000 85 N/A 50-000 PH00K55 N Wire Parallel N/A 0.75-0.9 0 x 65 M8 x 0 0.08 0000 85 N/A Standard Ignitors 80/0V ±0% 50/60Hz 000-000 PT50K5 N Superimposed 5.0-6.0 5 x 0 M8 x 0 0.5 00 90 5 600-000 PXE5085 N Superimposed.0-5.0 90 x 9 x 50 M8 x 0 0.5 50 90 5 0 500 PBE5085 N Superimposed 8.0-5.0 6 x M x 0.96 00 90 0 600-000 PB500K5 N Impulser N/A.0-5.0 5 x 5 M8 x 0 0.8 5000 85 N/A 000-000 PBA0085 N Wire Parallel N/A.0-.5 5 x 0 M8 x 0 0. 0000 85 N/A Timed Ignitors 0/0V ±0% 50/60Hz 5-70 PCX07055 Y Superimposed.8-. 0 x 75 M8 x 0 0.8 00 05 0 5-50 PCX0055 Y Superimposed 5.5-.5 0 x 75 M8 x 0 0.8 00 05 0 600-000 PCX00055 Y Superimposed.5-5.0 60 x 9 M x 0.5 00 05 0 70 PJ070K55 Y Impulser N/A.8-. 9 x 7 M8 x 0 0. 500 90 N/A 50 PJ09K55 Y Impulser N/A.0-.5 9 X 7 M8 x 0 0. 000 90 N/A 50-00 PJ0K55 Y Impulser N/A.0-.5 9 x 7 M8 x 0 0. 000 90 N/A 600 PJ600K55 Y Impulser N/A.0-.5 9 x 7 M8 x 0 0. 500 90 N/A 000 PJ000K55 Y Impulser N/A.0-.5 9 x 7 M8 x 0 0. 500 90 N/A Timed Ignitors 80/0V ±0% 50/60Hz 000-000 PCT505 Y Superimposed 5.0-6.0 60 x 9 M x 0.5 00 90 5 ATEX Approved Ignitors 0/0V ±0% 50/60Hz 5-70 PXA07055 N Superimposed.8-. 78 x 9 x 6 M8 x 0 0. 00 90 0 0 5-50 PXA0055 N Superimposed 5.5-.0 78 x 9 x 6 M8 x 0 0. 00 05 5 0 70-00 PXA0055 N Superimposed 5.5-.5 5 x 95 M8 x 0 0.5 00 90 0 600-000 PXA00055 N Superimposed.5-5.0 90 x 9 x 50 M8 x 0 0.5 00 05 5 0 5-70 PCA07055 Y Superimposed.8-. 0 x 6 x 0 M8 x 0 0.5 00 90 0 0 5-50 PCA0055 Y Superimposed.5-.0 0 x 6 x 0 M8 x 0 0.5 00 90 0 0 70-00 PCA0055 Y Superimposed 5.5-.5 0 x 6 x 0 M8 x 0 0.5 00 90 0 0 Ignitors 0V ±6% 50/60Hz for SOX lamps 5 PB05K5 N Wire Parallel N/A 0.7-0.9 0 x 65 M8 x 0 0.08 5000 85 N/A Note ➀ 5-55 PB055K5 Y Wire Parallel N/A 0.7-.0 5 x 75 M8 x 0 0. 5000 85 N/A 90 PB090K5 Y Wire Parallel N/A 0.7-.0 5 x 75 M8 x 0 0. 5000 85 N/A Ignitor 00V ±6% 50/60Hz for SDX lamps 70-50 PIE5005 N Superimposed.8-.5 7 x x M8 x 0 0.5 00 90 0 8 fig 0 fig fig fig Notes Note ➀ Suitable for 0V Note ➁ For 600W HPS maxium lead capacitance 00pF +() 085-0 Fax +() 085-0077 www.venturelightingeurope.com E-mail: sales@venturelighting.co.uk

Capacitors 50V Grip Wire Plastic Case M8 x stud fixing Value (uf) Tolerance Product Type Dimensions Fig Order Code Box Dia x L. (mm).0 ±0% /50 5 x 5 8 R008CR00P5 65 5.0 ±0% 5/50 5 x 5 8 R008CR050P6 0 6.0 ±0% 6/50 5 x 70 8 R008CR060P5 65 8.0 ±0% 8/50 0 x 7 8 R008CR080P5 0 0.0 ±0% 0/50 0 x 7 8 R008CR00P5 0.0 ±0% /50 0 x 7 8 R008CR0P5 0 6.0 ±0% 6/50 5 x 7 8 R008CR60P5 85 0.0 ±0% 0/50 0 x 70 8 R008CR00P5 85 5.0 ±0% 5/50 5 x 98 8 R008CR50P5 85 0.0 ±0% 0/50 0 x 9 8 R008CR00P5 65 0.0 ±0% 0/50 50 x 98 8 R008CR00P5 65 50V Grip Wire Plastic Case Snap-in fixing Value (uf) Tolerance Product Type Dimensions Fig Order Code Box Dia x L. (mm).0 ±0% /50 5 x 5 0 RIFRLCR00P5 0 6.0 ±0% 6/50 5 x 70 0 RIFRLCR060P5 0 8.0 ±0% 8/50 0 x 7 0 RIFRLCR080P5 0.0 ±0% /50 0 x7 0 RIFRLCR0P5 0 50V Grip Wire Alluminium Case M8 x stud fixing Value (uf) Tolerance Product Type Dimensions Fig Order Code Box Dia x L. (mm).0 ±0% /50 5 x 58 7 R008CR00A5 65.0 ±0% /50 5 x 58 7 R008CR00A5 65 6.0 ±0% 6/50 5 x 76 7 R008CR060A5 65 8.0 ±0% 8/50 0 x 76 7 R008CR080A5 0 0.0 ±0% 0/50 0 x 76 7 R008CR00A5 0.0 ±0% /50 0 x 76 7 R008CR00A5 85 0.0 ±0% 0/50 0 x 00 7 R008CR00A5 65 0.0 ±0% 0/50 50 x 00 7 R008CR00A5 65 50V 00mm Leads Plastic Case M8 x stud fixing Value (uf) Tolerance Product Type Dimensions Fig Order Code Box Dia x L. (mm).5 ±0%.5/50 5 x 5 7 R008HP05P5 65.0 ±0%.0/50 5 x 5 7 R008HP00P5 65.0 ±0%.0/50 5 x 5 7 R008HP00P5 65.0 ±0%.0/50 5 x 5 7 R008HP00P5 65 5.0 ±0% 5.0/50 5 x 70 7 R008HP050P5 65 5.5 ±0% 5.5/50 5 x 70 7 R008HP055P5 65 6.0 ±0% 6.0/50 5 x 70 7 R008HP060P5 65 7.0 ±0% 7.0/50 5 x 70 7 R008HP070P5 65 7. ±0% 7./50 0 x 7 7 R008HP07P5 65 8.0 ±0% 8.0/50 0 x 7 7 R008HP080P5 0 8. ±0% 8./50 0 x 7 7 R008HP08P5 0 0.0 ±0% 0./50 0 x 7 7 R008HP00P5M 0.0 ±0% /50 0 x 7 7 R008HP0P5 0.0 ±0% /50 5 x 7 7 R008HP0P5 85 5.0 ±0% 5/50 5 x 7 7 R008HP50P5 85 6.0 ±0% 6/50 5 x 7 7 R008HP60P5 85 8.0 ±0% 8/50 5 x 7 7 R008HP80P5 85 0.0 ±0% 0/50 5 x 98 7 R008HP00P5M 65 5.0 ±0% 5/50 5 x 98 7 R008HP50P5 85 0.0 ±0% 0/50 0 x 9 7 R008HP00P5M 65 5.0 ±0% 5/50 0 x 9 7 R008HP50P5 65 0.0 ±0% 0/50 50 x 98 7 R008HP00P5 65 5.0 ±0% 5/50 50 x 98 7 R008HP50P5 0 50.0 ±0% 50/50 50 x 98 7 R008HP500P5 0 55.0 ±0% 55/50 50 x 98 7 R008HP550P5 5 60.0 ±0% 60/50 50 x 98 7 R008HP600P5 0 Continued on page 50 Quantity Quantity Quantity Quantity Ballasts Capacitors fig 7 fig 8 fig 0 L fig 7 L 9 +() 085-0 Fax +() 085-0077 www.venturelightingeurope.com E-mail: sales@venturelighting.co.uk

Capacitors Ballasts Capacitors 50V 00mm Leads Plastic Case Snap-in fixing Value (uf) Tolerance Product Type Dimensions Fig Order Code Box Dia x L. (mm).0 ±0% /50 5 x 5 7 RIFRLHP00P5 65 6.0 ±0% 6/50 5 x 70 7 RIFRLHP060P5 0 8.0 ±0% 8/50 0 x7 7 RIFRLHP080P5 0.0 ±0% /50 0 x7 7 RIFRLHP0P5 0 50V 00mm Leads Alluminium Case M8 x stud fixing Value (uf) Tolerance Product Type Dimensions Fig Order Code Box Dia x L. (mm).0 ±0% /50 5 x 58 7 R008HP00A5 65.0 ±0% /50 5 x 58 7 R008HP00A5 65 6.0 ±0% 6/50 5 x 76 7 R008HP060A5 65 8.0 ±0% 8/50 0 x 76 7 R008HP080A5 0 0.0 ±0% 0/50 0 x 76 7 R008HP00A5 0 0.0 ±0% /50 6 x 76 7 R008HP00A5 65 0.0 ±0% 0/50 0 x 00 7 R008HP00A5 65 0.0 ±0% 0/50 50 x 00 7 R008HP00A5 65 50V 00mm Leads Plastic Case M8 x stud fixing Value (uf) Tolerance Product Type Dimensions Fig Order Code Box Dia x L. (mm) 6.8 ±0% 6.8/50 0 x 7 7 R008HP068P5 85 7. ±0% 7./50 5 x 7 7 R008HP07P5 85 8. ±0% 8./50 5 x 7 7 R008HP08P5 85.0 ±0% /50 5 x 98 7 R008HP0P5 85 5.0 ±0% 5/50 0 x 9 7 R008HP50P5 85 8.0 ±0% 8/50 0 x 9 7 R008HP80PRE 85 0.0 ±0% 0/50 50 x 98 7 R008HP00P5 65 5.0 ±0% 5/50 50 x 98 7 R008HP50P5 65 0.0 ±0% 0/50 50 x 98 7 R008HP00P5 0 0.0 ±0% 0/50 55 x 0 7 R008HP00P0 0 5.0 ±0% 5/50 50 x 98 7 R008HP50PN 0 Quantity Quantity Quantity 50V Grip Wire Plastic Case M8 x stud fixing Value (uf) Tolerance Product Type Dimensions Fig Order Code Box Dia x L. (mm) 5.0 ±0% 5/50 0 x 7 8 R008CR050P 0 Quantity Additional Capacitors on pae 9 fig 7 fig 8 fig 0 fig 7 50 L L +() 085-0 Fax +() 085-0077 www.venturelightingeurope.com E-mail: sales@venturelighting.co.uk

Circuit Diagrams 5 D L N Ph 0V 0V 0V D L N N 0V 0V 0V 8 7 6 5 6 5 D L N Ph 80V 00V 5V Y BL Ph N 0V 5 0V 5 0V 6 50V 6 ESS. CAP. -7 Y 0V 0V 0V D L N 5 D N Lamp 0V 0V 0V D N D 80V 00V 5V D L N 6 5 5 Ph 5W 55W Lamp 80V 00V 5V D L N ESS. CAP. -5 Ballasts Technical Information Ph D 0V 0V 0V 50V Ph ESS. CAP. - N Ph 0V 0V 0V 0V 5 Ph BR 0V 0V 5 0V 0V 5 5 BL Y BR Y BL BR D L N 6 5 Ph BR 0V 0V 5 0V 0V 5 Ph BR 80V 00V 5V Ph D 50W 0V 0V 70W 0V 0V D N ESS. CAP. -5 5 Ig Lp N Ph Lamp 0V 0V 0V 50V Lp 0V 0V 5 +() 085-0 Fax +() 085-0077 www.venturelightingeurope.com E-mail: sales@venturelighting.co.uk

Technical Information Ballasts Circuit Diagrams D L N D 0V 0V BL Y BR Ph BR 0V 0V Lamp 0V 0V H J K L M N Q 5 Y BL BR Ph BR 80V 00V 5V 5 0V 5 D L N Ph D 0V 0V 0V 5V D L N D 50W 70W Ig Lp N Lp 0V 0V BL Y BR Ph Y BR 0V 0V 0V 5V BL Y BR Ph Y BR 0V 0V 0V 50V D L N Ph 80V 00V 5V D 0V 0V Y BL Y 0V 0V D L N D 0V 0V D L N D L N D L N R 6 S 5 T 5 5 D L N Ph 80V 00V 5V 0V 5 Ph N 0V 0V 0V 5 50V 5 PFC. CAP. -5 S TRANSFORMER 6 5 Ph 0V 0V 0V ESS. CAP. 5-6 Lamp 5W 55W P 5 D 50Hz 0V 60Hz 0V lg Lp N lg Lp Ph 50W 0V 0V 70W 0V 0V D L N 50Hz 60Hz Ph D 90V 0V 00V 0V 0V 0V 0V 0V 0V 50V 5 0V 60V 5 U 5 BL Y BR V 5 D L N W L N Dimming Earth brown blue white green/yellow BLACK BLACK X Sense Suitable Power Switch D L N 50Hz 60Hz Ph Y BR 90V 0V 00V 0V 0V 0V 5 0V 0V 5 0V 50V 5 0V 60V 5 50Hz 60Hz Ph D 00V 0V 0V 0V 0V 0V 0V 50V 0V 60V 5 50V 70V 5 Ph 0V 0V Power N Full Dim 5 +() 085-0 Fax +() 085-0077 www.venturelightingeurope.com E-mail: sales@venturelighting.co.uk

Y Z 5 Circuit Diagrams A 50Hz 60Hz Ph Y 00V 0V 0V 0V 0V 0V 0V 50V 0V 60V 5 50V 70V 5 C D E F TRANSFORMER G H J K Y BL BR L M N D L N Ph D 00W 0V 0V 50W 0V 0V D L N ESS CAP - Ph BR 0V 0V Y BL BR BL Y BR 50Hz 60Hz Ph Y BR 00V 0V 0V 0V 0V 0V 5 0V 50V 5 0V 60V 5 50V 70V 5 Y BL Y BL Y 0V 0V Y 0V 0V 5 Y BL D L N D 50W 00W Y BL BR D L N Y BL Ph Y BR 0V 0V 0V 50V B P 5 60Hz 90V 00V 0V 0V 0V 0V 5 Y BL 50Hz Ph Y 0V 0V 0V 0V 50V 5 60V 5 Y BL BR 50Hz 60Hz Ph Y BR 00V 0V 0V 0V 0V 0V 5 0V 50V 5 0V 60V 5 50V 70V 5 D L N 50Hz 60Hz D 00V - - 80V D L N Ballasts Technical Information Ph BR 80V 5V 0V Ph 80V 5V 0V Ph Y 0V 0V 0V 50V 5 Q R S 5 T BL BR R Y 50Hz 60Hz Ph Lamp 00V 0V 0V 0V 0V 0V 0V 50V 0V 60V 5 50V 70V 5 N 50Hz 60Hz Ph Lamp 90V 0V 00V 0V 0V 0V 0V 0V 0V 50V 5 0V 60V 5 P Ig Lp N Lp 0V 0V U Earth L N WiMAC V Earth L N W Earth Lsw Z 5 N 0V 0V 0V 5 +() 085-0 Fax +() 085-0077 www.venturelightingeurope.com E-mail: sales@venturelighting.co.uk

Glossary of Terms Glossary 5 Arc Tube: A completely sealed quartz or ceramic tube where the electrical discharge (arc) occurs and generates light Auxiliary Light: Back-up light source to the HID light; typically a quartz halogen type Ballast: A device that, by means of resistance, inductance, capacitance or electronic elements, singly or in combination, controls the current, voltage and waveform to the required values for proper lamp starting and operation for a HID ballast operating at a given supply voltage Ballast Characteristic Curve: The curve of lamp wattage vs. lamp voltage over a range of normal lamp voltages, when a HID ballast operates at a given supply voltage Ballast Factor: Typically associated with fluorescent systems; metal halide ballasts are designed to operate lamps at rated watts, whereas some fluorescent systems are designed to operate at a fraction of rated watts Burning Position: The position in which lamps are designed to operate Cold Start Time: The amount of time from the application of ballast voltage to ignition of the arc discharge Colour Rendering Index (Ra): A measure of a light source s ability to render colours relative to a standard Constant Wattage Autotransformer (CWA) Control Gear: An autotransformer lead ballast circuit incorporating a capacitor in series with the lamp; compared to other ballasts, the CWA regulates over a wider input voltage range, holding lamp wattage to a narrow range by controlling lamp current Correlated Colour Temperature (CCT): The perceived colour of the light emitted by a lamp expressed in Kelvin (K units) Current Crest Factor: The ratio of the peak to the rms value of lamp current; metal halide values range from.5 to.8 Economic Life: The number of hours a group of lamps will burn before it is economically and aesthetically advisable to group relamp (typically 60% to 75% of rated life) Efficacy (Lamp): A ratio of lumens to watts; often calculated with either lamp watts or system watts; measured in lumens per watt (LPW) Formed Body Arc Tube: Precisely reproducible ellipsoidal arc tube formed by Venture s quartz sculpting process; has / less quartz mass than standard arc tubes for equivalent lumens; has no starter electrode HID: High Intensity Discharge lamps; includes metal halide, mercury vapor and high pressure sodium Hot Restart or Restrike Time: The amount of time from return of power after an interruption to the point of lamp ignition Ignitor: An electronic device which provides, by itself or in combination with other circuit components, the appropriate electrical conditions to start a discharge lamp Ignitor CWA Control Gear: CWA control gear using an ignitor to start the lamp Initial Lumens: The light output of a lamp, based on photometry results, at rated wattage after 00 hours of operation Input Voltage at Lamp Dropout (Extinction Voltage): The rms value of supply voltage at which a reference lamp extinguishes when the supply voltage is uniformly reduced from rated value at % to % of rated voltage per second Input Watts: The power measured on the input terminals of a ballast which is operating a reference lamp Lag Ballast: A ballast exhibiting primarily inductive electrical characteristics, including a lagging lamp current with respect to line voltage and lagging or corrected line power factor. Lamp Voltage: The voltage at which lamps operate when they are fully warmed up Lamp Wattage: The power consumed by a lamp after warm-up Light Center Length (LCL): The distance from the center of the arc discharge to the end contact of the base Lumens: A measurement of light output; takes into account the human eye sensitivity curve so that more weight is given to the yellow-green part of the light spectrum Lumen Maintenance: The lumen output provided by a lamp at a given point in or percentage of its life Lumens Per Watt (LPW): A ratio of lumens to watts; often calculated with either lamp watts or system watts; measured in lumens per watt (LPW) Luminaire Requirements: The type of luminaire a lamp requires; i.e., enclosed or open rated Maximum Overall Length (MOL): The maximum allowable distance from the top of the glass bulb to the end contact of the base Normal (Low) Power Factor Ballast: A ballast of the multiple-supply type that does not have a means for correcting the input power factor Occupancy Sensor: Control device that dims or turns lights off after the space becomes unoccupied; may be ultrasonic or infrared-actuated Open Circuit Current (Line): The RMS current measured through the input terminals of a ballast with lamp removed or inoperative Open Circuit Voltage, Ballast (OCV): The voltage across the output terminals of a ballast when no load is connected (RMS, unless otherwise stated) Open Rated Lamp (E7): Designed for open luminaires; has a narrower neck than standard E7 base lamps. Lamp arc tube is surrounded by a protective quartz shroud. Open Rated Lamp (E0): Designed for open luminaires. Lamp arc tube is surrounded by a protective quartz shroud. Operating Current (Line): The power factor corrected current measured through the input terminals of a ballast which is operating a reference lamp Operating Voltage: The voltage at which lamps operate when they are fully warmed up Peak Lead Ballast: A ballast that produces a highly peaked open circuit voltage wave shape and has a capacitor in series with the lamp Position Oriented Mogul Base (POMB, EP9, EP0): Used with horizontal burning lamps; has an aligning pin embedded in the base for proper lamp orientation when it is screwed +() 085-0 Fax +() 085-0077 www.venturelightingeurope.com E-mail: sales@venturelighting.co.uk

Glossary cont. Warranty Arc Tube: A completely sealed quartz or ceramic tube where the electrical discharge (arc) occurs and generates light Auxiliary Light: Back-up light source to the HID light; typically a quartz halogen type Ballast: A device that, by means of resistance, inductance, capacitance or electronic elements, singly or in combination, controls the current, voltage and waveform to the required values for proper lamp starting and operation for a HID ballast operating at a given supply voltage Ballast Characteristic Curve: The curve of lamp wattage vs. lamp voltage over a range of normal lamp voltages, when a HID ballast operates at a given supply voltage Ballast Factor: Typically associated with fluorescent systems; metal halide ballasts are designed to operate lamps at rated watts, whereas some fluorescent systems are designed to operate at a fraction of rated watts Burning Position: The position in which lamps are designed to operate Cold Start Time: The amount of time from the application of ballast voltage to ignition of the arc discharge Colour Rendering Index (Ra): A measure of a light source s ability to render colours relative to a standard Constant Wattage Autotransformer (CWA) Control Gear: An autotransformer lead ballast circuit incorporating a capacitor in series with the lamp; compared to other ballasts, the CWA regulates over a wider input voltage range, holding lamp wattage to a narrow range by controlling lamp current Correlated Colour Temperature (CCT): The perceived colour of the light emitted by a lamp expressed in Kelvin (K units) Current Crest Factor: The ratio of the peak to the rms value of lamp current; metal halide values range from.5 to.8 Economic Life: The number of hours a group of lamps will burn before it is economically and aesthetically advisable to group relamp (typically 60% to 75% of rated life) Efficacy (Lamp): A ratio of lumens to watts; often calculated with either lamp watts or system watts; measured in lumens per watt (LPW) Formed Body Arc Tube: Precisely reproducible ellipsoidal arc tube formed by Venture s quartz sculpting process; has / less quartz mass than standard arc tubes for equivalent lumens; has no starter electrode HID: High Intensity Discharge lamps; includes metal halide, mercury vapor and high pressure sodium Hot Restart or Restrike Time: The amount of time from return of power after an interruption to the point of lamp ignition Ignitor: An electronic device which provides, by itself or in combination with other circuit components, the appropriate electrical conditions to start a discharge lamp Ignitor CWA Control Gear: CWA control gear using an ignitor to start the lamp Initial Lumens: The light output of a lamp, based on photometry results, at rated wattage after 00 hours of operation Input Voltage at Lamp Dropout (Extinction Voltage): The rms value of supply voltage at which a reference lamp extinguishes when the supply voltage is uniformly reduced from rated value at % to % of rated voltage per second Input Watts: The power measured on the input terminals of a ballast which is operating a reference lamp Lag Ballast: A ballast exhibiting primarily inductive electrical characteristics, including a lagging lamp current with respect to line voltage and lagging or corrected line power factor. Lamp Voltage: The voltage at which lamps operate when they are fully warmed up Lamp Wattage: The power consumed by a lamp after warm-up Light Center Length (LCL): The distance from the center of the arc discharge to the end contact of the base Lumens: A measurement of light output; takes into account the human eye sensitivity curve so that more weight is given to the yellow-green part of the light spectrum Lumen Maintenance: The lumen output provided by a lamp at a given point in or percentage of its life Lumens Per Watt (LPW): A ratio of lumens to watts; often calculated with either lamp watts or system watts; measured in lumens per watt (LPW) Luminaire Requirements: The type of luminaire a lamp requires; i.e., enclosed or open rated Maximum Overall Length (MOL): The maximum allowable distance from the top of the glass bulb to the end contact of the base Normal (Low) Power Factor Ballast: A ballast of the multiple-supply type that does not have a means for correcting the input power factor Occupancy Sensor: Control device that dims or turns lights off after the space becomes unoccupied; may be ultrasonic or infrared-actuated Open Circuit Current (Line): The RMS current measured through the input terminals of a ballast with lamp removed or inoperative Open Circuit Voltage, Ballast (OCV): The voltage across the output terminals of a ballast when no load is connected (RMS, unless otherwise stated) Open Rated Lamp (E7): Designed for open luminaires; has a narrower neck than standard E7 base lamps. Lamp arc tube is surrounded by a protective quartz shroud. Open Rated Lamp (E0): Designed for open luminaires. Lamp arc tube is surrounded by a protective quartz shroud. Operating Current (Line): The power factor corrected current measured through the input terminals of a ballast which is operating a reference lamp Operating Voltage: The voltage at which lamps operate when they are fully warmed up Peak Lead Ballast: A ballast that produces a highly peaked open circuit voltage wave shape and has a capacitor in series with the lamp Position Oriented Mogul Base (POMB, EP9, EP0): Used with horizontal burning lamps; has an aligning pin embedded in the base for proper lamp orientation when it is screwed into its socket; should only be used in yellow Glossary & Warranty 55 +() 085-0 Fax +() 085-0077 www.venturelightingeurope.com E-mail: sales@venturelighting.co.uk

Europe Headquarters: Venture Lighting Europe Ltd. Trinity Court Batchworth Island Church Street, Rickmansworth, WD RT, United Kingdom +() 085-0 Fax: +() 085-0077 sales@venturelighting.co.uk Technical & Distribution Centre: Venture Lighting Europe Ltd. Unit, Willow Farm Business Park, Castle Donington, DE7 US, United Kingdom +() 0 856060 Fax: +() 0 85606 www.venturelightingeurope.com North America and World Headquarters: Venture Lighting International 000 Aurora Road Solon, Ohio 9 USA 800-5-606 0-8-50 Fax: 800-5-605 venture@adlt.com www.venturelighting.com Australia: Venture Lighting Australia 0 Lewis Road Wantirna South Victoria 5 Australia +(6) 9800 5600 Fax: +(6) 9800 55 sales@advancedlighting.com.au New Zealand: Advanced Lighting Technologies NZ LTD 8 Boeing Place, Mt Maunganui P.O.Box, Tauranga New Zealand +(6) 09-07 579 06 Fax: +(6) 09-07 579 06 light@adlt.co.nz Canada: Venture Lighting 6889 Rexwood Road Unit 6 & 7 Missisaugua, Ontario LV R Canada 905-678-69 Fax: 905-678-879 venturecanadasales@adlt.com Singapore: Advanced Lighting Technologies Asia Pte Ltd. Block 008, Ang Mo Kio Avenue 0 #0-06, Techplace I. Singapore 56965 (65) 68-8 Fax: (65) 68-9 vlseasia@adlt.com Japan: Venture Lighting Japan, Inc. Bunmeido Bldg. 6F 6-5, Taito -Chome Taito-Ku, Tokyo 0 (8) 0-89-57 Fax: (8) 0-89-7 vljapan@adlt.com Latin America: Venture Lighting International 5805 Blue Lagoon Drive Suite 95 Miami, Florida 6 USA 05-69-8 Fax: 05-69-877 vllatinamerica@adlt.com Middle-East: Venture Lighting International FZE P.O. Box 699 Jebel Ali, Dubai, U.A.E. (97-) 88-770 Fax: (97-) 88-77 ventufze@emirates.net.ae South Africa: Venture Lighting South Africa (PTY.) LTD. Unit, Boulevard Way Capricorn Business Park Marina Da Gama, South Africa +(7) -709-080 Fax: +(7) -709-098 vli-sa@iafrica.com India: Venture Lighting India Plot No. A0 D5 Phase II Zone B, MEPZ Tambaram, Chennai, India 60005 +(9) -809 +(9) -85567 Fax: +(9) -85569 Email: mail@vlindia.com Silver Group Member European HID Lighting Systems Catalogue E & OE As our policy is one of continuous development, we reserve the right to amend designs and specifications without prior notice. Every care has been taken to ensure that the contents of this document are correct at the time of publication and we shall be under no liability whatsoever in respect of such contents. LMPCAT.0.0.PO5.0M