Codes and Standards Enhancement (CASE) Initiative For PY2008: Title 20 Standards Development
|
|
|
- Melvyn O’Brien’
- 10 years ago
- Views:
Transcription
1 Codes and Standards Enhancement (CASE) Initiative For PY2008: Title 20 Standards Development Title: Analysis of Standards Options for High-Intensity Discharge Lighting Fixtures Prepared for: Pat Eilert Gary Fernstrom Ed Elliot Prepared by: Jennifer Thorne Amann American Council for an Energy-Efficient Economy Version: Preliminary CASE Report Last Modified: April 3, 2008 This report was prepared by Pacific Gas and Electric Company and funded by the California utility customers under the auspices of the California Public Utilities Commission. Copyright 2008 Pacific Gas and Electric Company. All rights reserved, except that this document may be used, copied, and distributed without modification. Neither PG&E nor any of its employees makes any warranty, express of implied; or assumes any legal liability or responsibility for the accuracy, completeness or usefulness of any data, information, method, product, policy or process disclosed in this document; or represents that its use will not infringe any privately-owned rights including, but not limited to, patents, trademarks or copyrights.
2 TABLE OF CONTENTS 1 EXECUTIVE SUMMARY PRODUCT DESCRIPTION METAL HALIDE LIGHTING SYSTEMS Metal Halide Lamps Ballasts for Metal Halide Lamps HIGH PRESSURE SODIUM LIGHTING SYSTEMS High Pressure Sodium Lamps Ballasts for High Pressure Sodium Systems HID FIXTURES MANUFACTURING AND DISTRIBUTION CHANNEL OVERVIEW ENERGY USAGE TEST METHODS Current Test Methods Proposed Test Methods BASELINE ENERGY USE PER PRODUCT EFFICIENCY MEASURES STANDARDS OPTIONS ENERGY USE PER PRODUCT MARKET SATURATION AND SALES CURRENT MARKET SITUATION Baseline Case High Efficiency Options SAVINGS POTENTIAL STATEWIDE CALIFORNIA ENERGY SAVINGS OTHER BENEFITS AND PENALTIES ECONOMIC ANALYSIS INCREMENTAL COST DESIGN LIFE LIFECYCLE COST / NET BENEFIT ACCEPTANCE ISSUES INFRASTRUCTURE ISSUES APPLICATION ISSUES EXISTING STANDARDS Federal Standards Interaction with Title 24 of California s Building Code STAKEHOLDER POSITIONS RECOMMENDATIONS RECOMMENDED STANDARDS OPTIONS PROPOSED CHANGES TO THE TITLE 20 CODE LANGUAGE REFERENCES... 19
3 1 Executive Summary The Pacific Gas and Electric Company (PG&E) Codes and Standards Enhancement (CASE) Initiative Project seeks to address energy efficiency opportunities through development of new and updated Title 20 standards. Individual reports document information and data helpful to the California Energy Commission (CEC) and other stakeholders in the development of these new and updated standards. The objective of this project is to develop CASE Reports that provide comprehensive technical, economic, market, and infrastructure information on each of the potential appliance standards. This CASE report covers standards and options for high-intensity discharge (HID) lighting fixtures. Approximately 2% of lamps installed in commercial and industrial facilities are HIDs. HID lighting systems (i.e., lamps and ballasts) account for 16% of the total lighting electricity consumed indoors in these sectors, equaling more than 80 billion kwh per year. The 54.9 million HID systems in outdoor stationary applications consume an additional 50 billion kwh per year. Although HID technology has evolved in recent years, widespread adoption of more efficient products has lagged behind the mainstream introduction of these products, particularly in the retrofit market. Federal regulation of HID lighting systems has taken effect only recently, with the ban on mercury vapor (MV) ballasts set to take effect in 2008, and the adoption of minimum ballast efficiency requirements for metal halide (MH) fixtures scheduled for January The federal standard for metal halide fixtures is based somewhat on standards effective in California beginning in Furthermore, federal law explicitly allows California a one-time opportunity to set new standards for MH fixtures that exceed the federal standards taking effect in Additional energy savings could be realized in California with adoption of expanded standards on HID lighting systems. In this analysis, we evaluate standards options for MH and high pressure sodium (HPS) fixtures based on the energy savings and costs associated with available replacement options. Our findings suggest that the energy savings and performance benefits of MH fixtures with higher efficiency ballasts outweigh the retrofit costs, with a benefit-cost ratio of approximately Existing MH systems can be upgraded to high-efficiency products for an average net present value of $95 in savings per unit. We recommend that the current ballast efficiency requirement for MH fixtures be revised to require electronic or equivalent efficiency ballasts. Specifically, we recommend minimum ballast efficiency of 90% for 150W to 274W fixtures, and 92% for fixtures of 275W to 500W. Standards for HPS fixtures are not warranted at this time, but should be reevaluated at a later date. We project this standard will save 173 to 538 GWh of electricity, and avoid 31 to 96 MW of peak demand in California. PG&E CASE Page 3 Last Modified: April 3, 2008
4 2 Product Description The predominant HID light sources are metal halide and high pressure sodium. 1 We will cover each source in turn and then discuss HID luminaires. 2.1 Metal Halide Lighting Systems Metal Halide Lamps MH lamps were introduced in the 1960s. The lamps consist of a quartz or ceramic arc tube (or discharge tube) containing a starter gas, mercury, and metal halide salts. An outer envelope or bulb contains the arc tube, which operates at high temperature and pressure. The metal halide arc tube requires a high voltage (higher than the voltage supplied by building electrical systems) to start the lamp. As a result, a ballast is required to supply the correct starting voltage and to regulate the starting and operating currents. As the temperature and pressure within the arc tube increase, the compounds in the arc tube vaporize to emit light. The glass outer envelope encapsulating the arc tube provides an inert or vacuum atmosphere to prevent high temperature oxidation of the arc tube components, and limits the amount of ultraviolet radiation emitted from the lamp. MH lamps are available with either probe-start or pulse-start technology. Probe-start lamps are started when a discharge is created across the small gap between the starter electrode (or starting probe electrode) and one of two operating electrodes, causing electrons to jump across the arc tube to the second operating electrode. A resistor is required to prevent burn up of the probe and a bi-metal switch removes the starting electrode from the circuit once the lamp is started. Pulse-start MH lamps rely on a high-voltage ignitor pulse to replace the need for the starter electrode. The ignitor and ballast start the lamp through a series of high-voltage pulses. By eliminating the starting probe electrode, the life of the lamp is increased and the seal area at the base of the arc tube can be reduced in area relative to a probe-start arc tube, and in turn heat loss is reduced. In addition, the higher fill gas pressure of the pulsestart arc tube leads to a reduction in the build up of tungsten that blackens the arc tube and reduces lamp performance in probe-start lamps. Traditionally, probe-start lamps have been more common except for medium-base MH lamps, where pulse-start is used because of arc tube size limitations that will not accommodate the starter electrode required in probe-start lamps. As of January 2008, probe-start ballasts are no longer permitted in watt MH fixtures manufactured for sale in California (the same requirement for fixtures with a vertical base-up MH lamp position went into effect in January 2006). Ceramic MH lamps, which also utilize pulse-start technology, use ceramic rather than quartz arc tubes. Ceramic arc tubes can tolerate a higher temperature, resulting in improved color rendering and color temperature, and in some cases, better efficacy. The 1 Another HID source is mercury vapor. The market share for mercury vapor lamps has been declining steadily since 1990 and in January 2008 sales of mercury vapor ballasts will be banned under the federal Energy Policy Act of As a result, mercury vapor lighting systems are not addressed in this report. PG&E CASE Page 4 Last Modified: April 3, 2008
5 improvements in color performance make ceramic MH particularly attractive in retail and other color-sensitive environments. Ceramic MH lamps use mostly the same ballasts as pulse-start MH lamps. Pulse-start MH lamps are available with rated lamp power ranging from 20W to 1000W. At this time, ceramic MH lamps of 20W to 400W are available. This CASE report focuses on mid- to high-wattage pulse-start MH lamps (i.e., 150W and higher). It should be noted that metal halide lamps come in three major configurations lamps designed for vertical operation (base up and/or base down), lamps designed for horizontal operation, and universal position lamps (that can be operated in any orientation). Lamps designed for vertical and horizontal operation are optimized for these positions and have better efficacy and life than universal position lamps operating in these same positions. Pulse-start metal halide lamps are most widely available for vertical operation, but the availability of horizontal and universal pulse-start products has grown in preparation for state standards slated to take effect in Figure 1: Metal Halide Lamps Pulse-start MH lamp Ceramic MH lamp Ballasts for Metal Halide Lamps A range of ballasts are available for use with MH lamps. Both magnetic and electronic ballasts are available for pulse-start MH lamps, however electronic ballasts currently account for only an estimated 3-5% of pulse-start ballasts. Magnetic pulse-start ballast systems include constant-wattage autotransformer (CWA), linear reactor, HX lag, and regulated lag. CWA are lead-style ballasts for pulse-start lamps, comparable to the CWA ballasts common in probe-start systems. Pulse-start CWA technology offers good power regulation with modest ballast losses, handling voltage dip variations of up to 45%. These ballasts reduce ballast losses by 5-10 watts relative to probe-start CWA ballasts. Linear reactors (or reactor ballasts) and HX lag ballasts are both lag-style ballasts, offering improved ballast efficiency and lamp performance relative to CWA but less power regulation. Reactor ballasts are only available in 277 volts and are suited for areas with PG&E CASE Page 5 Last Modified: April 3, 2008
6 very little variation in line voltage. Compared to CWA ballasts, reactor ballasts can reduce power input by up to 35 watts; however, their sensitivity to power quality and specific voltage requirements limit their applicability. Regulated lag ballasts have the most sophisticated design of the magnetic pulse-start ballasts providing good power regulation as well as improved lumen maintenance. Drawbacks of this design are a large physical size, lower efficiency, and higher cost compared to other MH ballasts. Electronic ballasts for MH lamps can offer several advantages over magnetic ballasts, but higher costs, lamp/ballast compatibility, reliability and limited availability have limited their use. Benefits of electronic ballasts can include reduced size, higher power factor, reduced ballast losses (greater efficiency), cooler operation, improved lamp lumen maintenance, better color stability, longer lamp life, and improved dimming capability. Electronic ballasts for mid-wattage MH lamps typically operate at high frequency, although low-frequency square wave ballasts (common for lamps of 150W and under) are being introduced for mid-wattage lamps to address concerns about acoustic resonance and electromagnetic interference. Although still a small fraction of pulse-start ballast sales, the market for electronic ballasts has been growing and accounts for roughly 3 to 5 percent of the current pulse-start ballast market at power levels below 150W. The number of manufacturers producing electronic ballasts is on the rise, and the range of products has grown to include lower-cost, non-dimming ballasts, as well as dimming ballasts for select lamps. In order to compete with T5 and high-output T8 fluorescents and high-wattage CFLs, manufacturers continue to conduct research and introduce improved MH lighting systems, including quartz and ceramic pulse-start MH lamps optimized for use with electronic ballasts. 2.2 High Pressure Sodium Lighting Systems [Note: we plan to add descriptive information on high pressure sodium lamps and ballasts in subsequent versions of this CASE report. At this time, there has been little improvement in magnetic ballasts for HPS systems and concerns persist about the performance of electronic HPS ballasts on the market so we are not recommending standards for HPS products at this time. However, there are some early indications with new products that electronic HPS ballasts may prove more reliable than electronic MH ballasts in some applications, but this needs to be borne out with further development and use of the technology. Given concerns about the performance and reliability of current electronic MH ballasts in outdoor applications, we are recommending some exclusions for these applications to prevent backsliding from MH to HPS in outdoor fixtures. HPS ballasts may warrant more detailed examination and consideration in the next round of standards rulemaking.] High Pressure Sodium Lamps PG&E CASE Page 6 Last Modified: April 3, 2008
7 2.2.2 Ballasts for High Pressure Sodium Systems 2.3 HID Fixtures Metal halide and other HID lamps are used in a variety of fixtures, including recessed fixtures (particularly for lamps of less than 150 Watts), wall-mounted fixtures (often called wall packs), streetlights and pole-mounted fixtures, sports-lighting luminaires, and interior industrial- and commercial-type fixtures. These latter fixtures are particularly common in such applications as warehouses, manufacturing facilities, malls and big box retail, and gymnasiums. Industrial- and commercial-type fixtures generally come in high-bay and low-bay types, where high-bay fixtures are designed for installation 20 or more feet above floor level and low-bay for lower mounting heights. Low-bay fixtures generally have special drop lenses to distribute light over a wider distribution angle, a consideration that is much less important for high-bay fixtures due to their higher mounting height. High-bay fixtures are generally made out of spun-aluminum, but products are also available with more reflective surfaces or with prismatic outer shells. Conventional spun-aluminum, high-bay fixtures typically have a luminaire efficiency of about 75%, meaning about 75% of the light from the lamp exits the fixture and the remaining 25% becomes trapped in the fixture and ultimately converted from light to heat. Fixtures with more reflective surfaces or prismatic fixtures (whose outer shell is transparent or translucent, permitting some light to escape upwards to illuminate the ceiling) typically have efficiencies of 90% or more. Clear and translucent fixtures partially illuminate the ceiling, reducing the cave effect (making a room look like a cave) glare, and improving contrast ratios. Figure 2: Typical high-bay and low-bay MH fixtures High-bay: Open die-cast aluminum Low-bay: Enclosed die-cast aluminum PG&E CASE Page 7 Last Modified: April 3, 2008
8 3 Manufacturing and Distribution Channel Overview The U.S. market for HID lamps is highly concentrated. Three manufacturers General Electric (GE), OSRAM Sylvania, and Philips Lighting account for the majority of HID lamp sales with EYE Lighting, Ushio America, and Venture Lighting making up the remainder. A larger number of manufacturers produce ballasts for the U.S. market. The number of companies making electronic HID ballasts has grown in recent years; however, two manufacturers left the market in Leading manufacturers include: Electronic and magnetic ballasts Advance Transformer, GE, Holophane, OSRAM Sylvania, Universal Ballast, Venture Lighting Electronic ballasts only AMF Technology, Green Earth, IEPC, Metrolight, Romlight Magnetic ballasts only EYE Lighting The luminaire market is also fairly concentrated with three manufacturers Cooper Lighting, Acuity Brands Lighting and Genlyte Thomas Group representing over half of the domestic market. More than 20 other manufacturers produce HID luminaires for the U.S. market. Major distribution channels for HID lighting systems include large electrical distributors selling to contractors, and larger customers including building managers, maintenance contractors, developers, utilities, municipalities, and mail-order distributors serving smaller businesses and contractors. Large maintenance companies and other customers may buy directly from manufacturers. 4 Energy Usage 4.1 Test Methods Current Test Methods A widely used test method for MH and other HID lamps is LM-51-00, published by the Illuminating Engineering Society of North America (IESNA). This standard is titled Electrical and Photometric Measurements of High Intensity Discharge Lamps. It is regularly updated, with the most recent version published in The American National Standards Institute (ANSI) publishes test methods for magnetic and electronic ballasts. Magnetic ballasts are covered in ANSI C Ballasts for High Intensity Discharge Lamps Method of Measurement. For electronic ballasts, ANSI_ANSLG C Low-Frequency Square Wave Electronic Ballasts for Metal Halide Lamps provides specifications and operating characteristics for low-frequency electronic MH ballasts including reference to the test methods outlined in ANSI C82.6. Standards for high-frequency electronic MH ballasts have not been published, but are now being developed with completion anticipated in approximately 3 years. PG&E CASE Page 8 Last Modified: April 3, 2008
9 4.1.2 Proposed Test Methods We recommend using the current test methods referenced above for magnetic and lowfrequency electronic ballasts. The new test method under development for highfrequency electronic ballasts should be adopted once it is published. Enactment of a standard for mid- to high-wattage MH fixtures could put pressure on the process and ensure publication of the new test method to meet the effective date of the standard. 4.2 Baseline Energy Use Per Product Baseline energy consumption varies depending on the specific lamp/ballast combination and the application. Table 2 summarizes per fixture energy use for mid-wattage MH systems meeting the current California standards for metal halide fixtures (i.e., pulse-start metal halide system with minimum ballast efficiency of 88%). Table 2. Baseline MH Energy Use Baseline Lamp (Wattage) Input Power (W) a Annual Energy Consumption (kwh/yr) b 175W W W W W W W Source: Manufacturer catalogs unless noted. a Assumes pulse-start lamp with ballast efficiency of 88% per California Title 20 standards. b Assumes typical operating hours of 12 hours/day per weighted average commercial, industrial, and outdoor stationary usage (DOE 2002). 4.3 Efficiency Measures Improvements in MH fixture efficiency can be realized through increases in luminaire efficiency or ballast efficiency. Common spun-aluminum, high-bay fixtures have a luminaire efficiency of about 75%, whereas comparable fixtures incorporating reflective surfaces or prismatic outer shells typically have luminaire efficiencies of 85% or higher. Higher luminaire efficiency permits the use of lower wattage lamps, while maintaining desired light levels. The efficiency of the base case MH system described above can be improved through the use of higher efficiency ballasts. High-efficiency/low-loss CWA ballasts now on the market have ballast efficiencies of 91% to 92%, thereby reducing power consumption by 5W to 20W per fixture depending on lamp wattage. In applications with a single line voltage and good power quality, dedicated 277 voltage (or even 240 voltage) linear reactor ballasts (with efficiencies of 93% to 94%) can reduce power consumption by PG&E CASE Page 9 Last Modified: April 3, 2008
10 10W to 30W per fixture. Additional energy savings can be realized through the use of electronic ballasts and improved reflectors/fixtures. Electronic ballasts can have efficiencies of up to 94% for some lamp wattages and some designs can yield additional energy savings by improving lamp lumen maintenance and allowing for the use of dimming. Further efficiency improvements can be realized through the use of lamps with better lumen maintenance. Reported lumen maintenance values for pulse-start MH lamps range from 55% to 85%, with most lamps in the range of 75% to 81% mean lumens after 40% of rated lamp life. Better lumen maintenance not only extends the useful life of the lamps, but allows for the installation of lower wattage lamps to yield the desired level of light over the life of the lamp. 4.4 Standards Options Energy Use Per Product For this CASE study, we focused our analysis on revised standards for new MH fixtures. Specifically, we looked at options for revising the current ballast efficiency requirements for MH fixtures that took effect in January 2006 and 2008 to account for improvements in ballast efficiency. We initially considered system efficacy requirements (i.e., lamp/ballast system lumens per watt) and lamp lumen maintenance requirements, such as a mean maintained lumens requirement, which would account for lamp and ballast efficiency as well as lamp lumen maintenance; however, we ultimately decided to concentrate on ballast efficiency. System approaches combining lamp efficacy and ballast efficiency are very complicated given the wide range of lamps available on the market. Standards establishing system efficacy requirements would require fixture manufacturers to test all possible lamp and ballast combinations, or shipping fixtures with lamps as well as ballasts to ensure compliance. As a result, a system efficacy standard or other approaches incorporating lamp efficacy, are much more difficult and costly to implement. Stronger ballast efficiency requirements will reduce ballast energy consumption and are easier to establish and implement since fixtures are routinely shipped with ballasts. In many cases, higher efficiency ballasts also yield lumen maintenance improvements. Figures 1 and 2, respectively, illustrate the distribution of electronic and magnetic pulsestart ballasts currently available by wattage and manufacturer reported ballast efficiency. Figure 1 shows that almost all of the electronic ballasts on the national market exceed the current California ballast performance standards for MH fixtures according to manufacturer literature. In fact, for all lamp wattages above 150W there are products available with reported efficiencies exceeding 90%. Above 250W, all electronic ballasts exceed 92% ballast efficiency. In contrast, the number of magnetic ballasts meeting or exceeding the current standards is limited, although magnetic ballasts are the only type listed in the CEC database of certified products exceeding 90% efficiency as of February 2008 (two magnetic pulse-start ballasts are listed with efficiencies of 94% and 93.7%). PG&E CASE Page 10 Last Modified: April 3, 2008
11 Figure 1: Available Electronic Pulse-Start MH Ballasts Pulse Start Ballasts: Electronic Ballast efficiency (%) 96% 94% 92% 90% 88% 86% Current CA std Lamp Wattage (W) Figure 2: Available Magnetic Pulse-Start MH Ballasts by Type Pulse-Start Ballasts: Magnetic Ballast efficiency (%) 96% 92% 88% 84% 80% Lamp Wattage (W) CWA Linear Reactor HX-HPF Given these findings, we analyzed energy savings from a standard requiring electronic ballasts or equivalent efficiency for MH systems in California. Since pulse-start systems offer a range of benefits, such as improved lumen maintenance, that can contribute additional energy savings, we did not consider reversing the ban on probe-start ballasts in PG&E CASE Page 11 Last Modified: April 3, 2008
12 California. Table 3 presents the standards option evaluated and estimated per fixture energy use. Energy use is reported with the low-end of the range incorporating an estimated 10% improvement in lumen maintenance associated with electronic MH ballasts; the high-end of the range does not include any lumen maintenance benefits. 2 practice, lumen maintenance savings would be achieved through reduction in lamp wattage or number of fixtures used. In Table 3. Energy Use for Standard Option Requiring Electronic Ballast or Equivalent Lamp Ballast Efficiency Requirement (%) Input Power (W) Annual Energy Consumption (kwh/yr) 175W 90% W 90% W 90% W 92% W 92% W 92% W 92% Source: Manufacturer catalogs unless noted. Assumes typical operating hours of 12 hours/day (DOE 2002) 5 Market Saturation and Sales 5.1 Current Market Situation Baseline Case The 2002 U.S. Lighting Market Characterization (DOE 2002) estimates that there are a total of 34.8 million MH lamps operating in commercial, industrial, and outdoor stationary applications, accounting for 33% of the installed base of high-intensity discharge (HID) luminaires. This translates into an existing stock of 3.3 million MH lamps in operation in California since the state accounts for about 9.6% of U.S. commercial building floor area (CEC 2003). MH lamps are the most common HID source in the commercial and industrial sectors, accounting for 63% and 71% of installed luminaires, respectively. MH lamps make up a smaller portion of outdoor stationary HID, accounting for only 9% of the installed HID base, which is predominately highpressure sodium (67%). Mercury vapor makes up the remaining 24%, but its overall market share has been declining steadily since 1990, and will continue to erode with the January 2008 federal ban on MV ballasts. The 2003 Commercial Buildings Energy Consumption Survey (EIA 2005) reports that 33% of lit commercial building floorspace in the five states of the Pacific census division includes some use of HID lighting. 2 According to a leading manufacturer s product literature, electronic ballasts increase mean lumens to 86% relative to 75% for magnetic pulse-start systems, an improvement of more than 14%. PG&E CASE Page 12 Last Modified: April 3, 2008
13 According to the National Electrical Manufacturers Association (NEMA), annual U.S. shipments of MH lamps totaled 18.6 million in 2001 and 19.2 million in 2002 (DOE 2003). If California also accounts for 9.6% of U.S. MH lamp sales, California sales totaled 1.79 million MH lamps in 2001 and 1.84 million MH lamps in 2002 (U.S. Census Bureau 2002). Shipments of MH lamps have increased every year since In contrast, shipments of high pressure sodium lamps have leveled off since the late 1990s, and shipments of mercury vapor have steadily declined since the early 1990s. HID fixture sales in 2000 and 2001, as compiled by the U.S. Census Bureau, total 12.6 million and 11.7 million, respectively. 3 These numbers include fixtures used for all HID sources, not just MH. Sales are greater in 2000 than in 2001 due primarily to the recession that took hold in As noted in the paragraph above, California accounts for about 9.6% of U.S. fixture sales, or roughly 1.1 million HID fixtures sold in 2001, including approximately 363,000 MH fixtures. Table 4 presents estimated statewide baseline sales, stock, and energy use for MH fixtures in California. Data on the relative proportion of high-bay versus low-bay fixtures are not widely available, but discussions with lighting distributors suggest that 90% of industrial-type fixtures are high-bay designs and 10% are low-bay. Sales of low-bay fixtures have been on the decline in recent years as a result of the growing popularity of high-output fluorescent lighting systems for low-bay applications. Table 4. California Statewide Baseline Sales, Stock and Energy Use California Annual % On California Annual Sales b Stock c Operating at Hours d Peak e Weighted Average System a Units Units (millions) California Energy Use and Demand MW GWh/year 398W MH system 254, ,380 78% 690 4,027 a Base case determined using current CA standard for typical 350W lamp with 88% efficient pulsestart ballast. b National sales data from U.S. Cenusus Bureau, California sales estimated at 9.6% of U.S. Commercial sales based on commercial floor area data from CBECS (EIA 2005) and 2002 population data from the U.S. Census Bureau. Assumes 70% of MH lamps sold are 150W to 1000W. c California existing stock data from CEC 2003 and EIA 2005 d Daily operating hours averaged for MH lamps in commercial and industrial from DOE 2002 e Peak coincidence 78% for commercial sector (based on PG&E 2000) As of January 2006, all new MH fixtures with vertical, base-up lamps of 150W to 500W can no longer include probe-start ballasts. In addition, ballasts included in the fixtures must meet a minimum ballast efficiency requirement of 88% this last requirement applies to all new fixtures, regardless of lamp-burning position, as of January While this has not had a big impact on the new construction and large-scale renovation markets, where the majority of projects in California have been using pulse-start MH 3 The Census Bureau no longer collects and reports data on HID fixture shipments 2001 is the last year for which this data is available. PG&E CASE Page 13 Last Modified: April 3, 2008
14 technology for at least 4 or 5 years (Nelson 2003), it is causing a big shift in retrofit and replacement markets where penetration rates of pulse-start MH have been much lower. Over time, this will also lead to an increase in sales of pulse-start metal halide replacement lamps. In the new construction, renovation, and retrofit markets, MH faces competition from other lighting technologies. Building owners interested in investing in new technology are installing high-output T5 fluorescent lighting, T8 fluorescents, CFLs, induction lighting, and LEDs, or retrofitting their existing HID systems with these alternatives. These technologies have advantages over MH in applications where occupancy sensors can yield substantial savings. Even with electronic ballasting, the restrike time for pulsestart MH is too long to allow occupancy sensors to completely turn the MH lamp and ballast off. In contrast, fluorescent and induction lighting have instant-on capability allowing sensors to completely turn lights off in unoccupied spaces, saving additional electricity High Efficiency Options At present, the majority of ballasts sold for pulse-start MH systems are magnetic CWA ballasts with efficiency in the range of 83% to 89%. High-efficiency/low-loss CWA ballasts with efficiency in excess of 90% are available from one manufacturer, but sales are still relatively low. Linear reactor ballasts are limited by their sensitivity to power quality and specific voltage requirements. Overall, higher efficiency alternatives have yet to capture significant market share, but the technology continues to improve. At the present time, experts estimate that electronic ballasts account for only about 3-5% of pulse-start MH ballast sales; however, this figure is expected to grow with interest in the higher efficiency, energy savings from lamp dimming and the other performance benefits associated with electronic ballasts. The number of manufacturers producing electronic ballasts continues to grow. As for fixtures, data on fixture sales by efficiency level are not compiled. However, it is estimated that 20-25% of current high-bay fixture sales have a luminaire efficiency of 85% or more. 6 Savings Potential 6.1 Statewide California Energy Savings Using the standards option outlined in Section 4.4, Table 5 estimates annual statewide energy savings. The range of savings accounts for savings with and without lumen maintenance benefits. PG&E CASE Page 14 Last Modified: April 3, 2008
15 Table 5. California Statewide Energy Savings From Proposed Standards Weighted Average System 398W MH system California Fixture Sales Percent Existing Fixtures with Electronic Ballast a Watts Saved per Fixture Percent on at Peak For First-Year Sales Coincident Peak Demand Reduction (MW) Annual Electricity Savings (GWh/yr) After Entire Stock Turnover Coincident Annual Peak Electricity Demand Savings Reduction (GWh) (MW) 254,100 5% % a ACEEE estimates based on discussions with industry experts. 6.2 Other Benefits and Penalties As noted above, electronic ballasts offer advantages beyond greater efficiency and improved lumen maintenance. Additional benefits can include reduced size, higher power factor, cooler operation, better color stability, longer lamp life, and improved dimming capability. The ability to incorporate dimming strategies for MH lighting can yield additional energy savings and help MH compete with linear fluorescent, CFL, and LED technologies. Electronic ballasts can have disadvantages as well. They must be kept cooler than electromagnetic ballasts. Whereas magnetic ballasts can reliably operate at temperatures between 130º and 180ºC, electronic ballasts generally must operate at component temperatures no higher than 85º to 115ºC. As a result, electronic ballasts may be larger than their magnetic counterparts and almost always have a different form factor. Differences in form factor and limitations in operating temperature require luminaires designed specifically for electronic ballasts and do not generally allow for interchangeable luminaire designs. The proposed standards would establish efficiency levels that can be met by electronic or magnetic ballasts to help address these issues. The proposed standards options analyzed here have the potential to impact future federal standards rulemakings as required by law. Details of the scheduled rulemaking process are discussed in Section 8.3. PG&E CASE Page 15 Last Modified: April 3, 2008
16 7 Economic Analysis 7.1 Incremental Cost Electronic MH ballasts are more expensive than magnetic ballasts, although the price has dropped some in recent years. At present, electronic ballasts incur an incremental cost from $60 to as much as $150. The most common products from the major manufacturers carry an incremental cost of $100 relative to magnetic pulse-start ballasts. However, as more manufacturers enter the market, the number of available models grows, and sales increase prices should continue to drop. Over the next few years, the incremental costs relative to other pulse-start MH ballasts can be expected to approach $ Design Life The rated lamp life for pulse-start MH lamps typically ranges from 15,000 to 25,000 hours. MH magnetic ballasts have a longer life, generally around 60,000 hours. Electronic ballasts typically have a shorter life of 30,000 to 50,000 hours depending on operating temperature. Ten hours is the daily burn time used in the test procedure. For this analysis, we have assumed a lamp design life of 20,000 hours or 4.5 years with an average burn time of 12 hours per day. In most applications, typical burn time is 12 hours per day. Using these same assumptions, a 60,000-hour magnetic ballast will have a life of 13.5 years and an electronic ballast can be expected to have a life of 9 years. As noted above, the typical fixture will have a life of 20 years but to make the calculations much easier, we use even multiples of lamp and ballast life and thus assume an average fixture life of only 9 years. 7.3 Lifecycle Cost / Net Benefit Table 6 summarizes the projected life cycle cost savings based on incremental cost and present value of lifetime energy savings calculations. Net present value estimates are based on average statewide present value electricity prices, as supplied by the California Energy Commission. Table 6. Costs and Benefits Per Unit Basecase Fixture (system wattage) Annual Energy Savings per unit (kwh) Life (yrs) Incremental Cost ($) a PV of Lifetime Energy Savings ($) b Lifecycle Benefit / Cost Ratio c NPV per unit ($) d 398W Pulse-Start MH $75 $ $95 a Incremental cost for electronic pulse-start MH ballasts based on manufacturer and distributor data at effective date of standard. b Calculated using the CEC s average statewide present value statewide energy rates that assume a 3% discount rate (CEC 2004). c Total present value benefits divided by total present value costs. d Positive value indicates a reduced total cost of ownership over the life of the appliance PG&E CASE Page 16 Last Modified: April 3, 2008
17 8 Acceptance Issues 8.1 Infrastructure Issues In response to California s current standards for MH fixtures, pulse-start MH lighting is becoming the norm in the retrofit market, and increasing its gains in new construction and major renovations. The growing availability of electronic MH ballasts, including the introduction of product lines from major manufacturers, should increase the market share of electronic versus magnetic ballasts particularly in applications where the other benefits of electronic ballasts outweigh their higher first costs. However, MH fixtures are expected to experience greater competition from other light sources in the coming years. In addition to competition from linear fluorescent and CFLs, new LED products designed for typical MH applications are coming into the market. The efficacy of these products is improving rapidly and costs are dropping. These products also offer much longer lifetimes, better dimming capability, and other benefits. 8.2 Application Issues As noted above, there are concerns that the proposed standards could result in some reversion to HPS in outdoor installations where more efficient MH systems would otherwise be used. This would increase outdoor lighting energy use and reduce lighting quality due to the poor scotopic properties of HPS lamps. A limited range of fixtures for outdoor applications are excluded from the existing California standards for MH luminaires. Specifically, excepted luminaires must be rated only for 150W lamps, be rated for use in wet locations, and contain a ballast rated to operate at ambient air temperatures above 50ºC. To address concerns about the performance of electronic and high efficiency magnetic ballasts in outdoor environments, we recommend continuation of the current exceptions and of the current standards requirements (i.e., pulse-start ballasts with 88% of higher ballast efficiency) for outdoor luminaires that do not meet the current exception. 8.3 Existing Standards Federal Standards The Energy Independence and Security Act of 2007, signed into law in December 2007, establishes federal standards for MH fixtures to take effect in January 1, The federal standard applies to fixtures for 150W to 500W MH lamps. The standard sets a minimum pulse-start MH ballast efficiency of 88%. Unlike California s MH fixture standard, the federal standard does not prohibit the use of probe-start ballasts; rather, magnetic probe-start ballasts must meet a stringent efficiency requirement of 94%. Nonpulse-start electronic ballasts must meet a minimum efficiency of 92% for wattages greater than 250W, or 90% for wattages less than or equal to 250W. The law explicitly excludes California s MH fixture standards from preemption and provides an opening for the California Energy Commission to adopt revised standards by January 1, PG&E CASE Page 17 Last Modified: April 3, 2008
18 Furthermore, the statute requires DOE to determine whether to revise the federal standards by January 2012; if a positive determination is made, the amended standards must be published at that time and will take effect by January A second determination must be published by January 2019, with an effective date of any amended standards required by January Any revised MH fixture standard adopted by California prior to the 2011 deadline will likely influence the federal rulemaking process Interaction with Title 24 of California s Building Code The standards proposed here affect new fixtures in commercial applications. Based on discussions with industry experts, it appears that the majority of new fixtures do not use the electronic ballasts proposed here and thus, this proposed standard will save a substantial amount of energy beyond the energy saved by Title Stakeholder Positions [This section will be completed after NEMA review of the draft and our meeting] 9 Recommendations 9.1 Recommended Standards Options Based on the cost-effective energy savings available from the use of electronic MH ballasts, a revised standard for new MH fixtures is warranted. We recommend that the current ballast efficiency requirement for MH fixtures be revised to require electronic or equivalent efficiency ballasts. Specifically, we recommend minimum ballast efficiency of 90% for 150W to 274W fixtures, and 92% for fixtures of 275W to 500W. Standards for HPS fixtures are not warranted at this time, but should be reevaluated at a later date. 9.2 Proposed Changes to the Title 20 Code Language [To be prepared later] PG&E CASE Page 18 Last Modified: April 3, 2008
19 10 References [CEC] California Energy Commission Update of Appliance Efficiency Regulations. CEC Publication # D; Appendix A, Table 22. July 2004 California Energy Commission Integrated Energy Policy Report, Appendix 1. October. Available online at Sacramento, CA: CEC. [DOE] Department of Energy US Lighting Market Characterization. Volume I: National Lighting Inventory and Energy Consumption Estimate. Washington, D.C.: Navigant Consulting, Inc.. Draft Framework for Determination Analysis of Energy Conservation Standards for High Intensity Discharge Lamps. June 30. Washington, DC: U.S. DOE. [EIA] Energy Information Administration Commercial Building Energy Consumption Survey Washington, DC: U.S. DOE. Harding, Tom (ADLT/Venture Lighting) Personal communication with Jennifer Amann. February. Nelson, Tom (Philips Lighting) Personal communication with Jennifer Thorne. August. [PG&E] Pacific Gas & Electric Company Energy Efficiency Programs Application, Attachment K, Workpapers. San Francisco, CA: PG&E. U.S. Census Bureau Electric Lighting Fixtures: Current Industrial Reports. MA335L(01)-1(RV). Washington, DC: U.S. Census Bureau Census 2000, Summary File 3 (SF 3). Available online at Washington, DC: U.S. Census Bureau. PG&E CASE Page 19 Last Modified: April 3, 2008
Metal Halide Pulse Start vs. Probe Start. By Dick Erdmann GE Specification Engineer
Pulse Start vs. Probe Start By Dick Erdmann GE Specification Engineer As we enter this new age of energy awareness, the lighting community has been at the forefront finding more and more ways to conserve
PPL Electric Utilities Energy Efficiency and Conservation Program
Category Measure Qualification Fixtures/Lamps Controls Incentive Amount T-8 Lighting Package Must replace T12. T8 Lamp Fixture $14/fixture (lamp & electronic ballast) High Performance / Replacing T12 $19/fixture
SYLVANIA METALARC Pulse Start Metal Halide Lamps
SYLVANIA METALARC Pulse Start Metal Halide Lamps Higher Lumen Maintenance+Longer Life METALARCPulseStart Improved Performance on Every Level The advanced arc tube design of SYLVANIA METALARC PULSE START
Cree Edge and LEDway by Cree Compared to Induction Lamp Luminaires
Cree Edge and LEDway by Cree Compared to Induction Lamp Luminaires Executive Summary There are many excellent reasons to select a Cree lighting system over one based upon induction technology, even though
LIGHTING and LIGHTING SYSTEMS
LIGHTING and LIGHTING SYSTEMS Introduction Lighting is an important area of opportunity for energy savings, since it is a large fraction of use of electricity in residential and commercial buildings. Lighting
Retrofit HID High Bay Fixtures to Long Life High Efficiency LED
Retrofit HID High Bay Fixtures to Long Life High Efficiency LED 2013 DyoCore Call us today for sales and pricing information: Toll Free: 877.849.6668 www.dyocore.com It is no hidden secret that LED bulbs
Small Business Lighting
Small Business Lighting Business Customer Information Opportunity ID: For a free lighting assessment, please contact the Small Business Lighting program at 1-877-287-2250. Company name Date submitted Billing
Kolorlux. GE Lighting DATA SHEET
GE Lighting Kolorlux High pressure Mercury lamps Kolorlux Standard 50W, 80W, 125W, 250W and 400W Kolorlux Deluxe 50W, 80W, 125W, 250W and 400W DATA SHEET Product information Kolorlux Mercury vapor lamps
General Lighting Recommendations
Design Guidelines for Energy Efficient Lighting Systems Thank you for your interest in energy efficiency! According to the US Department of Energy, 51% of the energy used in commercial buildings is consumed
LOWBAY INDUSTRIAL LIGHTING
COMBINING QUALITY DESIGN AND ENERGY EFFICIENCY FOR SMALL INDUSTRIAL FACILITIES Basics of Quality Lighting Economics of Energy Effective Lighting General Industrial Workspace Lighting Industrial Cleanrooms
Nashville Electric Service
Nashville Electric Service Specification ESL-601-1 Description: High Intensity Discharge Lamps 1.0 Scope... 2 2.0 General Requirements... 2 3.0 Information to be Returned... 4 4.0 NES Policy... 4 5.0 Revision
Guide to new, energy-efficient lighting technologies for your business
Guide to new, energy-efficient lighting technologies for your business Commercial lighting systems are changing rapidly, with new or improved technologies continuously becoming available. Whether you re
Lumination LED Luminaires
GE Lighting Lumination LED Luminaires Downlights RX Series Dependable Downlighting New GE Lumination RX Downlights are the economical choice for converting existing CFL sockets to the superior performance
induction lighting toll free: tel: fax:
Induction Lighting Introducing induction lighting Induction lamps are one of the newest energy-saving lighting technologies developed in recent years. Induction lighting is based on a technology that is
Business lighting guide
Business lighting guide Table of contents Advantages of energy-efficient lighting... Take Control & Save Business Lighting Program overview... Implementation and lighting audit walk-through... Introduction
T5 LongLast. GE Lighting DATA SHEET
GE Lighting T5 LongLast DATA SHEET Linear Fluorescent Lamps T5 LongLast High Efficiency 14W, 21W, 28W, 35W T5 LongLast High Output 24W, 39W, 49W, 54W, 8W Product information T5 LongLast lamps are triphosphor
Biax T/E. Triple Biax Compact Fluorescent Lamps Non-Integrated 13W, 18W, 26W, 32W and 42W. GE Lighting. Product description.
GE Lighting Biax T/E Triple Biax Compact Fluorescent Lamps Non-Integrated W, W, W, 32W and 42W Product description Ultra compact energy saving CFL lamps with triple-tube design give an ideal light source
Prescriptive Program Rebate Application
Prescriptive Program Rebate Application Check the appropriate program box for your rebate. OID Internal Use Only Cooling FSO (Fluid System Optimization) Foodservice Equipment Heating Lighting Motors &
Answers. T8 Fluorescent Lamps. ... Volume 1 Number 1 April 1993. Background. What does T8 mean?
T8 Fluorescent Lamps Answers........................................................ Volume 1 Number 1 April 1993 Background Throughout the 1970s, manufacturers of fluorescent lamps introduced new products
C2D LowBay: All the power, none of the bulk. C2D Advantage
LowBay LowBay: All the power, none of the bulk Combining superior performance and energy-efficiency with a low-profile modern design, the C2D LowBay provides excellent quality of light for enhanced visibility
WHAT S NEW IN THE 2013 CODE?
WHAT S NEW IN THE 2013 CODE? Changes to mandatory Title 24 lighting requirements California's new Building Energy Efficiency Standards take effect in 2014. They improve the energy efficiency of homes by
Highbay and Lowbay LED Luminaires. Energy-efficient, low-maintenance lighting for commercial and industrial applications
Highbay and Lowbay LED Luminaires Energy-efficient, low-maintenance lighting for commercial and industrial applications High Performance Highbay and Lowbay LED Luminaires AccuLite Highbay and Lowbay LED
Lutron Energy Savings Claims
Lutron Energy Savings Claims Commercial Claims page 2 Residential Claims page 11 Commercial Claims Commercial Claims These are claims currently utilized by Lutron for commercial product marketing. The
LicensedArchitect. $6.00 Volume 15, No. 3 Fall 2011. Association of Licensed Architects
$6.00 Volume 15, No. 3 Fall 2011 LicensedArchitect 2011 Chicago Architecture Conference - Tuesday, October 18 Accessibility Requirements for Hotels ALA Student Merit Winners CE Article - LED Illumination
IPS HIGH-BAY / LOW-BAY LIGHTING
HIGH-BAY / LOW-BAY LIGHTING NEW ALTERNATIVES TO H.I.D. New from SPI LIGHTING, an exciting addition to our family of fluorescent alternatives to traditional HID high-bay and low-bay lighting. The IPS Series
Multi-Vapor Metal Halide Lamps
GE Lighting Multi-Vapor Metal Halide Lamps Elliptical Clear 175W, 250W, 400W and 00W Elliptical Diffuse 175W, 250W and 400W High Output Elliptical Clear & Diffuse 250W and 400W DATA SHEET Product information
Small Commercial Business Energy Audits. Recognizing and addressing the special requirements of the small business market segment.
Small Commercial Business Energy Audits Recognizing and addressing the special requirements of the small business market segment. Class 4 Class 4: Lighting Fundamentals Basic Lighting Technology Advanced
Electric Sign Energy Certification Service To California Energy Commission Title 24 Technical Requirements and Audit Instructions (ENVS) Header Title
Header Title Subheadline Electric Sign Energy Certification Service To California Energy Commission Title 24 Technical Requirements and Audit Instructions (ENVS) Electric Sign Energy Certification Service
LED Tubular Lamp / Kit Guide
LED Tubular Lamp / Kit Guide LED lighting products have great potential to replace existing fluorescent lighting, reduce energy use and improve lighting quality in many indoor commercial applications.
Lumination LED Luminaires
GE Lighting Lumination LED Luminaires Downlights RI Series Heightened Performance Now just about any recessed downlight can benefit from advanced GE LED fixtures. New GE Lumination RI Series LED Downlights
HANDY INFORMAL LIGHTING GLOSSARY
HANDY INFORMAL LIGHTING GLOSSARY 2 nd Generation T8s Mid-grade 800 series T8s. Typically these F32T8s have 2950 3000 catalog or photopic lumens. 3 rd Generation T8s Also called Super T8s. High-lumen 800
High Bay Occupancy Sensor Selection Guide
High Bay Occupancy Sensor Selection Guide Make the most of your energy SM 1 2 Schneider Electric offers a vast array of lighting control sensors for HID and Fluorescent High Bay applications. HID High
T5 Watt-Miser Linear Fluorescent lamps
GE Lighting T5 Watt-Miser Linear Fluorescent lamps DATA SHEET T5 Watt-Miser High Efficiency 13W, 20W, 26W, 33W T5 Watt-Miser High Output 21W, 36W, 46W, 51W, 76W Product information T5 Watt-Miser lamps
Commercial Lighting Market Transformation Model Development and Market Research
Commercial Lighting Market Transformation Model Development and Market Research Phase I: T12 Retrofit and Replacement Market Presented to Energy Trust of Oregon Final Report September 8, 2011 Presented
DuroSite TM High Bay Lighting
DuroSite TM High Bay Lighting LED White Lighting Brochure for Industrial Applications CE version Application: The first of its kind, the Dialight DuroSite TM LED High Bay luminaire was designed specifically
Lighting Retrofit Incentive Application for Business Customers
Lighting Retrofit Application for Business Customers 2015 A Cash Energy Efficiency Program brought to you by: Instructions for Use: For complete instructions, please refer to the Terms and Conditions on
Property Risk Management HIGH INTENSITY DISCHARGE ELECTRICAL LIGHTING
Property Risk Management HIGH INTENSITY DISCHARGE ELECTRICAL LIGHTING 1 2 Introduction High Intensity Discharge (HID) lighting has been used for many years internally, in factories and warehouses, and
ENERGY SAVER. Energy efficient lighting Technology report
ENERGY SAVER Energy efficient lighting Technology report Second edition 2014 Published by: Office of Environment and Heritage Department of Premier and Cabinet 59-61 Goulburn Street, Sydney Australia Ph:
REVO-LB. REVO LB (Low Bay Industrial Luminaires)
REVO-LB REVO LB (Low Bay Industrial Luminaires) LOW BAY INDUSTRIAL LUMINAIRES The REVO-LB luminaires have been developed as a new series to be used on low ceilings (Low Bay) adding to our successful energy-saving
Home lighting. Bright ideas for energy savings
Home lighting Bright ideas for energy savings Shedding light on new technologies Lighting is one of the most visible ways you use energy in your home. While a single light bulb doesn t use much energy,
Energy efficient lighting for your home find out more.
Energy efficient lighting for your home find out more. There are many different types of lighting available on the market but with a little research you can ensure that the lighting in your home meets
HOW TO CONDUCT ENERGY SAVINGS ANALYSIS IN A FACILITY VALUE ENGINEERING STUDY
HOW TO CONDUCT ENERGY SAVINGS ANALYSIS IN A FACILITY VALUE ENGINEERING STUDY Benson Kwong, CVS, PE, CEM, LEED AP, CCE envergie consulting, LLC Biography Benson Kwong is an independent consultant providing
ENERGY EFFICIENT LIGHTING
ENERGY EFFICIENT LIGHTING Prof. Suryanarayana y Doolla IIT Bombay Dept. of Energy Science & Engineering Content 2 Basics of Illumination Types of light source, lighting Comparison of commercial lamps Energy
Led lighting products
With green technology at your service Led lighting products 3 years guarantee save up to 70% energy at the same time increasing luminosity! tisztaled.hu [email protected] Products list LED Tubes 3 LED
Applications. Architectural
GE Lighting Arcstream Single Ended Metal Halide lamps 7W and 15W DATA SHEET Product information Arcstream Single Ended lamp consists of a compact high pressure metal halide discharge operating in a quartz
High Pressure Mercury
High Pressure Mercury E27 B Product Description Mixed Light lamps Product Features High-pressure mercury tube in series with a tungsten filament Runs on mains voltage without additional gear Combines a
Introduction. Terms. LED Application Series: Outdoor Area Lighting
LED Application Series: Outdoor Area Lighting Building Technologies Program LED Application Series: Outdoor Area Lighting LED technology is rapidly becoming competitive with high-intensity discharge light
OPEN OFFICE T8 HP FLUORESCENT HIGH PERFORMANCE LENSED
OFFICE GUIDE 1 OPEN OFFICE T8 HP FLUORESCENT HIGH PERFORMANCE LENSED ROOM CHARACTERISTICS Length: 60' Width: 25' Height: 9' Reflectivity: Ceiling = 80% Walls = 50% Floor = 20% PRODUCT SPECIFICATIONS Photo
Industrial Solutions. Made to order. Imagine lighting as versatile as the industries it serves.
Industrial Solutions Made to order Imagine lighting as versatile as the industries it serves. The GE Advantage Our Industrial Lighting Systems come complete with service and support from GE, every step
Evolve LED Area Light
GE Lighting Evolve LED Area Light Scalable Area Light (EASA) imagination at work Product Features The next evolution of the GE Evolve LED Area Light continues to deliver outstanding features, while adding
In the following Temperature Profile Data Charts when a T code is used, this chart explains the temperature maximum (in degrees Celsius).
TEMPERATURE PROFILE DATA In the following Temperature Profile Data Charts, when a column is headed Tested Lamp Envelope Surface Temperature in C @ 40 C Maximum Ambient, the data (in degrees Celsius) was
DOE Solid-State Lighting GATEWAY Program. GATEWAY Registry and Demonstration Reporting Template. U.S. Department of Energy November 2008
DOE Solid-State Lighting GATEWAY Program GATEWAY Registry and Demonstration Reporting Template U.S. Department of Energy November 2008 Building Technologies Program Energy Efficiency and Renewable Energy
Green Building Handbook for South Africa Chapter: Lighting Luke Osburn CSIR Built Environment
Green Building Handbook for South Africa Chapter: Lighting Luke Osburn CSIR Built Environment Lighting consumes between about 29-35% of the energy used within commercial office space while lighting only
Session 15 Lighting Fundamentals
Session 15 Lighting Fundamentals Illumination Levels - Example Illumination Levels (Cont.) Lighting Sources in the International World Incandescent: -40⁰ C (-40⁰ F) Fluorescent: -20⁰ C (-4⁰ F) minimum
Commercial Energy Efficiency Program. Save money, reduce energy use and earn incentives. Save money, reduce energy use and qualify for incentives
Save money, reduce energy use and earn incentives by improving the energy efficiency of your business. Georgia Power s Commercial Energy Efficiency Program makes incorporating energy-efficient improvements
Commercial Energy Savings Guide. www.touchstoneenergy.coop
Commercial Energy Savings Guide www.touchstoneenergy.coop NRECA Pocket Savings Guide Pag.indd 1-3 2/7/05 4:19:07 PM Commercial Energy Saving Tips Notes: This guide provides basic hints on ways to reduce
ConstantColor CMH MR16
GE Lighting ConstantColor CMH MR16 Reflector Ceramic Metal Halide Lamps W and 35W DATA SHEET Product information ConstantColor CMH lamps combine HPS technology (providing stability, efficiency & uniformity)
Recessed. EvoKit LED Retrofit Kits Gen 3
Recessed EvoKit LED Retrofit Kits Gen 3 Project: Location: Cat.No: Type: Lamps: Notes: Qty: 2'x4' Philips EvoKit LED Retrofit Kit is an energy efficient LED alternative to traditional linear fluorescent
Business Energy Rebates Application
Business Energy Rebates Application Business Energy Rebates make it easy and affordable for you to select energy efficient products for your business. and mail-in rebates are available for energy efficient
AEDG Implementation Recommendations: Interior Lighting Sample Layouts for Office Buildings
AEDG Implementation Recommendations: Interior Lighting Sample Layouts for Office Buildings The Advanced Energy Design Guide (AEDG) seeks to achieve 30 percent savings over Standard 90.1-1999. This guide
Rated Lumen [lm] Nominal. Volts [V] [lm]
GE Lighting rcstream Metal Halide lamps Tubular Clear 25W and W Elliptical Diffuse 25W DT SHEET Product information High brightness, high quality white light with good colour rendition and energy efficiency
ARTIFICIAL LIGHTING lecture notes
ARTIFICIAL LIGHTING lecture notes Dr. Habil. András Majoros Figures, images and tables by Levente Filetóth Budapest University of Technology and Economics Faculty of Architecture Department of Building
(Refer Slide Time: 00:01:43 min)
Illumination Engineering and Electric Utility Services Prof. N.K. Kishore Department of Electrical Engineering Indian Institute of Technology, Kharagpur Lecture No. # 9 Discharge Lamps II Welcome to the
TECHNICAL GUIDE A GUIDE FOR THE SELECTION OF ENERGY EFFICIENT TECHNOLOGIES
TECHNICAL GUIDE A GUIDE FOR THE SELECTION OF ENERGY EFFICIENT TECHNOLOGIES Table of Contents 1. Introduction 1 2. Estimating Energy Savings and Costs 1 Direct Energy Savings 1 Indirect Energy Savings 2
The new generation of energy saving tube lighting
The new generation of energy saving tube lighting MASTER LEDtube GA The Philips MASTER LEDtube integrates a LED light source into a traditional fluorescent form factor. Its unique design creates a perfectly
Table of Contents HID Electronic and Electromagnetic Ballasts
Table of Contents HID Electronic and Electromagnetic Ballasts gelighting.com Ballasts Understanding Electronic UltraMax HID Ballasts...18-2 Understanding Electromagnetic HID Ballasts...18-3 Electronic
12 Volt Lighting Products
Low voltage DC bulbs are the most efficient light sources for using electrical energy produced with photovoltaic, wind and small hydro power systems. With low voltage DC lights, there are no power penalties
GE Lighting. Albeo LED Luminaire. Linear Industrial Low Bay Lighting. (ALV1 - Series) imagination at work
GE Lighting Albeo LED Luminaire Linear Industrial Low Bay Lighting (ALV1 - Series) imagination at work Product Features The Albeo ALV1-series LED luminaire is an energy-efficient, low maintenance alternative
Cree XLamp XM-L LED 10,000-Lumen High-Bay Reference Design
application note Cree XLamp XM-L LED 10,000-Lumen High-Bay Reference Design CLD-AP96 rev 0A Table of Contents Introduction... 1 Design approach/objectives... 2 The 6-step methodology... 2 1. Define lighting
Lighting New Construction Incentive Application for Business Customers
0 22016 Lighting New Construction Incentive Application for Business Customers A Cash Incentive Energy Efficiency Program brought to you by: Instructions for Use: For complete instructions, please refer
LED Retro Fit the next generation in energy efficiency. Converting existing 12v systems to LED
Benefits and Features of Retro Fitting with LED- LED Retro Fit the next generation in energy efficiency Converting existing 12v systems to LED Between 1960 and 1990, landscape lighting was still in the
Application Assessment of Bi-Level LED Parking Lot Lighting
Application Assessment of Bi-Level LED Parking Lot Lighting Host Site: Raley s Supermarket, West Sacramento, California Final Report prepared in support of the U.S. DOE Solid State Lighting Technology
Leaders In Industrial LED Lighting Solutions. CleanLED Highbay/Lowbay. Energy Efficient LED Lighting Solutions For Industry
Leaders In Industrial LED Lighting Solutions CleanLED Highbay/Lowbay Energy Efficient LED Lighting Solutions For Industry Introduction The Safelux Lighting CleanLED Highbay and Lowbay fixtures are high
Innovative. Lum. Flux** [lm]
www.osram.com SubstiTUBE Advanced ST8A-0.6m-8.9W-840-HF Datasheet Innovative LED-lamp, easy and safe to use in ECG installations as direct retrofit. Energy saving potential of up to 35% by replacing 0.6
CHAPTER 10: APPLIANCES AND LIGHTING
Chapter 10: Appliances and Lighting 151 CHAPTER 10: APPLIANCES AND LIGHTING According to the U.S. Environmental Protection Agency, appliances and home electronics account for 20% of energy bills in the
Petrol Station Canopies
Petrol Station Canopies High bay & Low Bay Warehouses & Factories Security Lighting General Area Lighting 320W High Bay Ideal for warehouses and factories, the Advantage Hi-Bay offers 20% energy savings
Evolve LED Area Light
GE Lighting Evolve LED Area Light Scalable Area Light (EASB) imagination at work Product Features The next evolution of the GE Evolve LED Area Light continues to deliver outstanding features, while adding
LG LED Road & Street Lighting
Copyright 2013 LG Electronics. All rights reserved. The information contained herein is subject to change without notice to improve product performance. LG LED Road & Street Lighting LED Road & Street
Residential Retail Lighting Programs: A Bright Future. March 2011
Residential Retail Lighting Programs: A Bright Future March 2011 Residential Retail Lighting Programs: A Bright Future By Shannon Montgomery Executive Summary Compact fluorescent lamp (CFL) residential
Biax S and S/E. Compact Fluorescent Lamps Non-Integrated 5W, 7W, 9W and 11W. GE Lighting DATA SHEET. Product information. Features.
GE Lighting Biax S and S/E Compact Fluorescent Lamps Non-Integrated 5W, 7W, 9W and 11W DATA SHEET information Biax S compact fluorescent lamps can provide savings of up to 73% in energy costs compared
Lighting Requirements
ASHRAE/IESNA Standard 90.1-1999 Lighting Requirements Joseph G. Howley Jr., IESNA GE Lighting Immediate Past Chair of ASHRAE SSPC 90.1 Lighting Subcommittee 1 How to Get the Standard Standard 90.1-2001
2016 Commercial Efficiency Program
1. I want to replace my fixture and put LED tubes in it. Do I get rebates for both the fixture and the tubes? No. This type of project qualifies for the LED tube rebate only. 2. Can I install any LED product
Energy and Energy Efficient Alternates Study
Chair Betty Reinbeck Commissioners William D. Darby Douglas Hartman Virginia Hermosa Brant C. Ince Mike Novak Alvin Shaw Executive Director Terry Keel Mailing address: P. O. Box 13047 Austin, TX 78711-3047
5YR. Advanced LED lighting. High performance industrial lighting. 50% energy against traditional fittings Up to 75% energy saving with sensing
High performance industrial lighting 50% energy against traditional fittings Up to 75% energy saving with sensing Zero maintenance, no need to relamp IK10 rated durable construction Advanced LED lighting
Energy Efficiency Best Practice Guide Lighting
5 Energy Efficiency Best Practice Guide Contents 1 Introduction 4 2 The business benefits of good lighting 5 2.1 Improved productivity 5 2.2 Improved safety 5 2.3 Improved colour rendering 5 2.4 Improved
A Guide to Energy Efficient and Cost Effective Lighting
A Guide to Energy Efficient and Cost Effective Lighting This guide provides information on how specifiers and designers can improve the quality and cost effectiveness of lighting schemes through the use
No-Cost LED street lighting modernization
John J. White, PE, Business Unit Manager, Energy Solutions, Eaton and Council Member for Borough of Seven Fields, Pa. Improve your municipality s image with LED lighting paid from energy savings Executive
The purpose of industrial lighting is to enable quick and accurate work, safely, and in a good visual environment. Points of note are:
5.4 Industry indoor Techniques General The purpose of industrial lighting is to enable quick and accurate work, safely, and in a good visual environment. Points of note are: Illuminance on the task is
LED HIGHBAY COMMERCIAL & INDUSTRIAL DESIGNED MANUFACTURED AND WARRANTED IN AUSTRALIA
COMMERCIAL & INDUSTRIAL LED HIGHBAY DESIGNED MANUFACTURED AND WARRANTED IN AUSTRALIA Experience counts Established in 2004, Aqualuma is a privately owned company based on the Gold Coast in Queensland,
HID Ballast Application Guide
HID Ballast Application Guide Table of Contents 1 Introduction To HID Lighting... 3 2 HID Lamp Types... 4 2.1 Mercury Vapor (MV)... 5 2.2 High Pressure Sodium (HPS)...6 2.3 Quartz Metal Halide (QMH)...